36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

Similar documents
COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

015 : 1993 CEB STANDARD

012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)

079 : 2000 CEB STANDARD ALUMINIUM BINDING WIRE

001: 2007 CEB STANDARD

SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

POTENTIAL TRANSFORMER

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION OF ELECTRICAL MATERIALS CT & PT GROUP C

CAPACITOR VOLTAGE TRANSFORMER

Technical Specification For 33 KV, Single Phase, Dead Tank Type Out Door Current Transformer Of Different Ratio

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

50-SDMS-01 SPECIFICATIONS FOR

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

MESP TECHNICAL SPECIFICATION FOR AN AUXILIARY OR ESSENTIAL SERVICES AND AUXILIARY TRANSFORMER FOR USE IN A RAILWAY SUBSTATION

MEDIUM VOLTAGE PRODUCT. KOKM Cable current instrument transformers Instruction for Installation, use and maintenance

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

TECHNICAL SPECIFICATIONS

Australian Standard. Instrument transformers. Part 1: Current transformers (IEC Ed.1.2 (2003) MOD) AS AS

TECHNICAL SPECIFICATION OF 11 KV AND 22 KV THREE PHASE FOUR WIRE, THREE

INTERNATIONAL STANDARD

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description:

Device Under Test: ALTEA VS- 24-I VS-24-I. 0 24/09/12 First issue A. Peretto L. Peretto 1 24/06/16 All text review E. Scala L. Peretto J. L.

Voltage Transformers type UMZ User s Manual, Operation and Maintenance

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS

071-3: 2009 CEB SPECIFICATION

TECHNICAL SPECIFICATION FOR 22 KV CURRENT TRANSFORMERS

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

General Electricity Company of Libya

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

TECHNICAL SPECIFICATION OF 11 KV THREE PHASE FOUR WIRE, THREE CTs COMBINED METERING CTPT SET OF ACCURACY CLASS 0.5s

51-SDMS-02 SPECIFICATIONS FOR DISTRIBUTION TRANSFORMERS UP TO 36KV 400/230 VOLTS

Status Date Prepared Reviewed Endorsed Approved

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

MEDIUM VOLTAGE PRODUCT. TPE 6x.xx Indoor supporting current transformers

Arild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems

51-SDMS-04 SPECIFICATIONS FOR. DISTRIBUTION TRANSFORMERS UP TO 36 kv WITH ALUMINUM WINDINGS FOR DUAL SECONDARY 400/230 V AND 230/133 V

Capacitive voltage transformers

S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013)

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

RING CORE CURRENT TRANSFORMERS FOR LOW VOLTAGE TYPE AOS USER MANUAL

DISTRIBUTION TRANSFORMER kv

SPTS 1 - Ratings and General Requirements for Plant, Equipment and Apparatus for The ScottishPower System and Connection Points to it.

LIGHTNING ARRESTOR. September 2017 WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED

NUCLEAR POWER CORPORATION OF INDIA LIMITED. (A Government of India Enterprise) TECHNICAL SPECIFICATION 220 KV CAPACITOR VOLTAGE TRANSFORMERS FOR

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

CEYLON ELECTRICITY BOARD SRI LANKA. Procurement of Plant

Arc Suppression Coils

MEDIUM-VOLTAGE MEASURING VOLTAGE TRANSFORMERS USER MANUAL

SPECIFICATION FOR 11 KV CLASS, 24/15.7, 30/19.7 & 45/29.5 AMPS SPECIAL DESIGN TRANSFORMERS.

SI.No Parameters CPRI Specification/Requirements To be Completed by the Bidder Guaranteed Technical

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

DISTRIBUTION TRANSFORMER 11 / kv

(TECHNICAL SPECIFICATIONS & GTP FORMATS) 11KV METERING UNITS

MEDIUM VOLTAGE PRODUCT. TJP 5.x Indoor voltage transformers

Inductive Voltage Transformers. Types VEOT and VEOS

Plant Client Contract Code Document ID Contract No. TECHNICAL SPECIFICATIONS DC SHUNT Rev 00 Page 1 of 2

GENERAL TECHNICAL SPECIFICATION (Turnkey Work)

CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS

VI 3 - i TABLE OF CONTENTS

Reference Number PPS 05 - (RIC Standard: EP SP)

INTERNATIONAL STANDARD

ASSEMBLY TOOLS FOR SCREWS & NUTS. Part 1: Insulated hand operated socket drive wrenches and screw drivers

AT Current Instrument Transformer Instructions for installation, use and maintenance

MAHARASHTRA STATE ELECTRICITY DISTRIBUTION COMPANY LTD. TECHNICAL SPECIFICATION FOR. 36 kv (PROTECTION CUM METERING) INSTRUMENT TRANSFORMERS

Capacitive voltage transformers

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

3. COMBINED TRANSFORMERS Oil-paper insulation

Types CDG 11 and CDG 16 Inverse Time Overcurrent and Earth Fault Relay

User s Manual For CT Model IMB

INSTRUMENT TRANSFORMERS. Right Choice for Metering and Protection of Power. Electricfield

DIRECT CONNECTED STATIC POLY PHASE ENERGY METER OF ACCURACY CLASS 1

Single-Phase Mini Pad-Mounted Transformer Specification: Energy+ MPDL

1.0 mh, 3150 A LINE TRAP

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM

SPECIFICATION FOR HIGH STRENGTH STRUCTURAL BOLTS

SPECIFICATION FOR SAFETY POLE SIGNS & ACCESSORIES

APDRP SCHEME, WESCO. Technical Specification for Distribution Transformers ( 11/0.4KV ) PART 1: GENERAL

Reactor and inductor are names used interchangeably for this circuit device.

Combined Instrument Transformers. Types IVOKT and TMC

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

INTERPLANT STANDARD - STEEL INDUSTRY

Ritz Instrument Transformers GmbH. Welcome

CUSTOMER SUPPLIED HIGH VOLTAGE METERING UNIT SPECIFICATION FOR 11, 22 & 33 kv

MEDIUM VOLTAGE PRODUCT. TJP 6.1, TJP 6.2 Indoor voltage transformers

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES

GUJARAT ENERGY TRANSMISSION CORPORATION LTD. SARADAR PATEL VIDYUT BHAVAN, RACE COURSE, BARODA TECHNICAL SPECIFICATIONS

NPS/002/016 Technical Specification for 33 kv Cable Joints and Terminations

MEDIUM VOLTAGE PRODUCT. PARAMETERS GUIDE How to specify the indoor instrument transformers correctly

TECHNICAL SPECIFICATION OF LT SHACKLE BOLT (G. I. BOLT) WITH NUT AND SPRING WASHER

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3

MEDIUM VOLTAGE PRODUCT. TJP 7.x Indoor voltage transformers

Transcription:

CEB STANDARD 022 : 1994 Specification for 36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE) CEYLON ELECTRICITY BOARD SRI LANKA

Specification for 36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE) CEB Standard 022 : 1994 CEYLON ELECTRICITY BOARD No. 50, Sir Chittampalam A. Gardiner Mawatha, Colombo 2. Sri Lanka Telephone: 24471-8 Telex : 21368 CE Facsimile: 94-1-449572

Amendment Slip No. 1 effective from 10th June 1994 to CEB Standard 022 : 1994 Specification for 36kV Voltage Transforemrs (Outdoor Type) REVISED TEXT June 1994 1. Clause 5.0 BASIC FEATURES 5.2 Manufacture 5.2.1 General Add the following Clause to read as, "(vi) The Secondary Terminal Box of the Voltage Transformers shall be provided with sealing facilities to prevent access to the unauthorised persons."

CONTENTS PAGE 1. Scope 2 2. System Parameters 2 3. Service Conditions 2 4. Applicable Standards 2 5. Basic Features 3 6. Additional Requirements 4 7. Information to be Supplied with the Offer 5 8. Technical Literature & Drawings 6 9. Inspection & Testing 6 10. Annexure - A 7 1

SPECIFICATION FOR 36 KV VOLTAGE TRANSFORMERS (OUTDOOR TYPE ) 1.0 SCOPE This specification covers the design, manufacture and testing of outdoor 36kV Voltage Transformers which are to be installed on 36kV overhead lines for protection as well as for measuring purposes. 2.0 SYSTEM PARAMETERS (a) Nominal Voltage : 33kV (b) System highest voltage : 36kV (c) System frequency : 50 Hz (d) Number of phases : 03 (e) Method of earthing : Resonant earthed/non effectively earthed Neutral system (f) System fault level : 25 KA 3.0 SERVICE CONDITIONS (a) Annual average ambient temperature : 30 C (b) Maximum ambient temperature : 40 C (c) Maximum relative humidity : 90% (d) Environmental conditions : Humid tropical climate of high pollution level. (e) Operational altitude : Upto 1500M above MSL. 4.0 APPLICABLE STANDARDS The equipment and components supplied shall be in accordance with the standards specified below or subsequent editions and / or amendments thereof. 2

(a) IEC 186 (1987) Voltage Transformer (b) BS 729 (1971) Hot dip galvanised coating on iron and steel articles. (c) IEC 296 (1982) Insulating Oil for Transformer and Switchgear. (d) BS 4190 (1957) Hexagnol Bolts and Nuts. 5.0 BASIC FEATURES 5.1 Design 5.1.1 The outdoor post-type Single Phase Voltage Transformers shall be designed for the system highest voltage (Rated Voltage) stipulated in clause 2.0 5.1.2 It shall be suitable for mounting on steel structures and necessary fixing bolts and nuts shall be supplied with the equipment. 5.1.3 Its windings shall be housed either in a high impact resistance porcelain insulator where normal mineral transformer oil will be the insulating medium or in a high impact resistance Cast Epoxy Resin. 5.2 Manufacture 5.2.1 General (i) (ii) (iii) (iv) (v) The primary and the secondary windings shall be made of high grade copper. The secondary terminals shall be enclosed in a weather proof terminal box with gland plates at the base of the Voltage Transformers. Lifting tackles shall be provided for lifting and positioning the transformers. The withstand ability of the primary, the saturation of the magnetic core and the secondary characteristic shall not be less than that requested in the Minimum Technical Requirements (Clause No. 5.2.5 ) For oil filled type Voltage Transformers, oil level indicator, earth lug etc. shall also be provided. The Voltage Transformers shall be hermetically sealed type and the insulator shall be made of glazed porcelain. The cast resin type Voltage Transformers shall have the core and coil assemblies cast in Epoxy Resin, which shall be suitable to withstand high thermal and dynamic stresses due to system and climatic fluctuations. Earth lug etc. shall also be provided. 3

5.2.2 Bolts and nuts All steel bolts and nuts shall conform to BS 4190: 1957 the standard specified and the nuts and heads of all bolts to be hexagonal type. 5.2.3 Galvanizing Except where specified to the contrary all iron and steel parts shall be galvanized after sawing, shearing, drilling punching, filing, bending, and machining etc., are completed. Galvanizing shall be by the hot-dip process to comply with the BS 729. 5.2.4 Creepage Distance The Voltage Transformer insulator creepage distance shall not be less than 900 mm and the protected creepage distance shall not be less than 315mm. 5.2.5 Minimum Technical Requirements (a) Transformations ratio : 33kV / 110V (b) Rated output : 25VA (c) Class of Accuracy : Cl. 1 (d) Rated Voltage Factor : 1.2 and Rated time : Continuous (e) Markings : Conforming to IEC 186 (f) Insulation level i) Impulse withstand voltage : 170 kv. ii) Power frequency wet withstand voltage (1min.) : 70 kv. 6.0 ADDITIONAL REQUIREMENTS 6.1 Terminal Markings The Primary and Secondary winding terminals shall be marked clearly and indelibly on their surface or in their immediate vicinity conforming to IEC 186. 4

6.2 Rating Plate markings Ratings and data of the Voltage Transformers shall be provided in the name plate which shall be weather and corrosion proof. The Name plate shall be securely attached to the side of the (lower part) Voltage Transformers so that it could be easily read from the ground level when it is installed at a height of 2.5 m from the ground level. It shall consist of the following information: - (a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) Number and year of the standard adopted. The manufacturer's identification A serial number or type designation, preferably both. The rated primary and secondary Voltage. The rated frequency. The rated output and the corresponding accuracy class. The highest rated equipment voltage The rated insulation level. Rated voltage factor and the corresponding rated time. Class of insulation. The words "Property of CEB". 7.0 INFORMATION TO BE SUPPLIED WITH THE OFFER. The following shall be furnished with the offer. (a) (b) (c) (d) (e) Catalogues describing the equipment and indicating the model number. Literature describing the operational features of the equipment. Constructional features, materials used for components and relevant technical literature. Complete dimensional drawings. Magnetization and core loss curves 5

(f) (g) (h) A list of names and addresses of ten recent purchasers (of similar items only) indicating quantities supplied, delivery time and the document from such purchasers certifying satisfactory performance of the equipment. Rating plate details. Completed Schedule of Particulars (ANNEXURE A). (i) Type Test Certificates - The Test Certificates and Performance Curves of the Type Test performed conforming to the IEC 186. The test certificates shall clearly identify the equipment concerned, showing the manufacturer's identity, type No. and basic parameters, and shall be from a recognised independent testing authority acceptable to the purchaser. Following Type Test reports shall also be submitted. (a) (b) (c) (d) (e) High-voltage, power-frequency wet withstand tests Lightning impulse voltage withstand test (dry). Temperature rise test. Tests for determination of errors. Short Circuit withstand capability test. Failure to furnish the particulars asked for in Clause 7.0 will result in the offer being rejected. 8.0 TECHNICAL LITERATURE AND DRAWINGS Technical Literature in English language on the installation and operation shall be supplied with each set of equipment and they shall be descriptive and self explanatory, complete with necessary diagrams and drawings. 9.0 INSPECTION & TESTING 9.1 Inspection The selected Bidder shall make necessary arrangements for inspection by an Engineer of the Ceylon Electricity Board to inspect the equipment and witness the routine test conforming to IEC 186. 6

9.2 Routine tests The routine tests which shall be witnessed are given below. (1) Verification of terminal markings. (2) Power-frequency withstand tests on i) Primary windings. ii) iii) Secondary windings. Between sections (3) Determination of errors. 10.0 ANNEXURE A - Schedule of Particulars 7

ANNEXURE - A SCHEDULE OF PARTICULARS The Bidders are required to furnish the following Particulars for each type of Voltage Transformer offered. ITEM DESCRIPTION DETAILS 1 Manufacturer - 2 Type - 3 Rated voltage kv 4 Rated frequency Hz 5 Rated primary voltage kv 6 Transformation ratio. V 7 Rated secondary burden VA 8 Rated insulation level i) Dry Impulse withstand voltage (1.2kV/50ìs) Peak Positive Wave +kv Negative Wave -kv ii) Power frequency withstand voltage kv 9 Creepage distance of the insulator mm. 10 Protected creepage distance mm. 11 Accuracy class - 12 Rated accuracy limit factor - 13 Voltage factor and rated time Sec. 14 Service conditions: Such as indoor or outdoor temperature conditions, altitude, humidity, suitability for exposure to steam, vapour, fumes, explosive gases, excessive dust, salt air etc. Should be stated. - 15 Special features (if any) - 16 Type of secondary 17 Volume of oil - 8

18 Measurement - 19 Total Weight - 20 no. of phases - 21 For non-composite capacitor voltage transformers: - (i) In a tapped bushing, the nominal capacitance & - p.f.values of C1 and C2 and the tolerance limit (ii) The maximum permissible working voltage on C1 kv 22 Connection drawings - vtt 9