SureGrip TM. XWWarning

Similar documents
80i-600A AC Current Probe

374/375/376 Clamp Meter

374/375/376 Clamp Meter

51-54 Series II. Thermometer

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

374 FC/375 FC/376 FC Clamp Meter

36 AC/DC True RMS. Clamp Meter. P Read First: Safety Information

323/324/325 Clamp Meter

HART Mode. Users Guide. July Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies.

Electrical Multimeter

742A Series Resistance Standards

T+ and T+ PRO Electrical Tester

80i-110s. AC/DC Current Probe Instructions. Introduction

12B/18 MultiMeter Instruction Sheet

Fluke 712B and 714B Temperature Calibrators

netzerotools.com 374/375/376 Users Manual Clamp Meter

374/375/376. Calibration Manual. Clamp Meter

Pro. SimpliFiber. Getting Started Guide. Optical Power Meter and Fiber Test Kits

Circuit Breaker Finder

MICROTOOLS MICRONETBLINK KIT

312, 316, 318. Clamp Meter. Users Manual

16 Multimeter with Temperature

1507/1503. Insulation Testers. Users Manual

712C. Users Manual. RTD Calibrator

15B & 17B. Users Manual. Multimeters

5520A. Service Manual. PQ Option

1523, 1524 Thermometer Readout User s Guide

AT Advanced Wire Tracer. Users Manual

15B & 17B. Multimeters. Users Manual

CT238A. AC/DC Current Probe. User Manual. For detailed specifications and ordering info go to

AM-500 Autoranging Mulitmeter. AM-500-EUR Digital Multimeter. Users Manual

Insulation Tester. Users Manual

16 Multimeter with Temperature

5520A. Operators Manual. PQ Option

712B/714B. Calibration Manual. RTD/Thermocouple Calibrator

For detailed specifications and ordering info go to

MINCO PRODUCTS, INC Commerce Lane, Minneapolis, Minnesota U.S.A. Telephone: (763) FAX: (763)

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

Models 110, 111 & 112

3M IDC Ribbon Cable Socket. Series 891

Glass Electrode Meter

3M High Routability External MiniSAS Cable Assembly 8G26 Series Product Specification Revised

Broadband Step-Up Transformer. User Manual

712B. Users Manual. RTD Calibrator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

1587/1577 Insulation Multimeters

Fluke 345. Power Quality Clamp Meter. The ideal meter for commissioning and troubleshooting modern electrical loads

MS6813. Users Manual TEST BNC MS6813 TRANSMITTER SHIELD OFF CONT TONE. Multi-Function Wire Tracer. Short Reversed Miswire Split Pairs

AM-520 AM-530. Users Manual. HVAC Multimeter. True-rms Electrical Contractor Multimeter

Troubleshooting RTDs and Thermocouples

3M Wiremount Socket Series CHG

TSSP-1 (Stainless Steel Thermistor Probe) Manual Rev A

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

AT Underground Cable/Pipe Locator System. Users Manual Mode d emploi Bedienungshandbuch Manuale d Uso Manual de uso Användarhandbok

VT02. Users Manual. Visual IR Thermometer

3M Power Clamp Wiremount Connectors

Fluke 83V and 87V Digital Multimeters

Webinar Organizers. Ryan Shea. Don Miller. Joe Ryan. Support Specialist. Applications Specialist. Product Manager. Precision Digital Corporation

902 FC. HVAC True-rms Clamp Meter

1507/1503. Insulation Testers. Technical Data. Features and benefits:

3 Shielded Compact Ribbon (SCR) Wiremount Plug, XX, and Shell Kit, F200-XXX

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

3M TM High Routability Internal MiniSAS Cable Assembly, Series 8F36

Operator s Manual. PP016 Passive Probe

9190A Ultra-Cool Field Metrology Well. Ultra-cool dry-block calibrator with best-in-class stability

Model 77 Series IV. Digital Multimeter. Users Manual

INSTRUCTION MANUAL. MODEL: Vintage 60R. Vintage Series Guitar Amplifi er

1587/1577. Insulation Multimeters. Users Manual. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

AM-560 Advanced HVAC Multimeter. AM-570 Industrial Multimeter. User Manual EN FR ES

2000 A AC TRUE RMS DIGITAL CLAMP METER WITH NON-CONTACT EF-DETECTION

Ultra-cool dry-block calibrator with best-in-class stability Technical Data. Improved process control

Broadband Current Probe Series Operation Manual

HHMA2 DC / TRUE RMS AC NON-CONTACT MILLIAMMETER

True-rms Multimeter. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com

Operator s Manual. PP022 Passive Probe

114, 115, and 117. True-rms Multimeters

INSTRUCTION MANUAL FOR CELL SIMULATOR MODEL 2410

Signal Integrity Test Report

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

1000A AC DIGITAL CLAMPMETER MODEL KM 3060

3M Mini D Ribbon (MDR) Cable Assembly.050" High Speed Digital Camera Link Cable Right Angle 14H26-SZLX-XXX-0LC

Calibration Manual. Power Quality Clamp Meter

Broadband Current Probe Series Operation Manual

LT3000 ULTRASONIC LEVEL TRANSMITTER

TENNADYNE TD-160HP800

AC68C. Users Manual. True RMS AC/DC Clamp Multimeter. PN July Amprobe Test Tools. All rights reserved.

AIS 300 Installation Instructions

Additel 875 Series Dry Well Calibrators

Directed Energy, Inc Oakridge Dr., Suite 100, Fort Collins, CO

SolderSleeve One-Step Wire and Cable Terminators. Selection Guide

Automated Thermocouple & RTD Calibrator

3M Mini D Ribbon (MDR) Cable Assembly.050 High Speed Digital Data Transmission System - 26 Position 14X26-SZLB-XXX-0LC

User s Guide TX93A. (J, K, T, E) 4-20 ma Ultra-Miniature Temperature Transmitters. Shop online at omega.com

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL- KM 2782 / 2782-T

Fluke 1587 FC/1577 Insulation Multimeters

Instruction Manual ICM 135R Electrical Clamp Multimeter EN FR IT DE ES

8808A. Digital Multimeter. Getting Started Manual. Specifications

n/a FLUKE 116 MULTIMETER

3M Scotchlok Insulated Electrical Spring Connector B (Blue)

Installation Tester and DMM Kits

3M Mini D Ribbon (MDR) Cable Assembly.050 Right-Angle High-Flex Digital Camera Cable 26 position 14H26-SZ3X-XXX-04C

Transcription:

80PK-22 SureGrip TM Immersion Temperature Probe Instruction Sheet XWWarning To avoid electrical shock, do not use this probe when voltages exceeding 24 V ac rms or 60 V dc are present. The probe tip is electronically connected to the output terminals. Introduction The 80PK-22 SureGrip TM Immersion Temperature Probe is designed for use in liquids or gels. The probe can also be used as a general purpose temperature probe. The thermocouple junction is protected from tip to handle by an Inconel sheath. The 40-inch (1 meter) cable is terminated with a Type K miniature thermocouple connector with 0.792-mm (0.312-in) pin spacing. The 80PK-22 can be used with any temperaturemeasuring instrument that is designed to accept Type K thermocouples and has a miniature connector input. Note The 80PK-22 is not recommended for use in food or beverage preparation. Use 80PK-25 for food preparation. Specifications Type K Standard grade Ni-Cr vs. Ni-Al (Chromel vs. Alumel) Measurement Range -40 C to 1090 C (-40 F to 1994 F) Accuracy (With respect to ANSI MC96.1-1982-Standard Limits of Error) Note All error calculations should be done in C, then scaled to F. Range -40 C to 293 C (-40 F to 559.4 F) 293 C to 1090 C (559.4 F to 1994 F) ±2.2 C ±0.75 % Accuracy (% of reading) November 2004 Rev.2, 9/09 2004-2009 Fluke Corporation. All rights reserved All product names are trademarks of their respective companies.

Output @ 25 C (77 F) =1.00 mv (reference junction @ 0 C) Seebeck Coefficient @ 25 C (77 F) = 40.50 μv / C Measurement Time (Time Constant): 3.0 seconds in 100 C still water at sea level pressure. Complete step change equals 5 time constants (3.75 seconds). Maximum Voltage 24 V ac rms or 60 V dc Maximum Temperature of Tip 1090 C (1994 F) Sheath Material: Alloy 600 Dimensions: Diameter: 3.175 mm (1/8 in) Length: 212.725 mm (8.375 in) Grounding Junction welded to sheath. Cable Length: 40 inches (1 meter) Insulation Material: PVC Maximum Temperature: 105 C (220 F) Jacket Color: Gray Conductors Type: K Size: AWG #24 stranded (7 strands of #32) Handle Material: Hytrel Maximum Temperature: 125 C (257 F) Connector Type: Mini-thermocouple connector with.792 mm (0.312 in) pin spacing Material: Yellow Hytrel Maximum Temperature: 125 C (257 F) Overall Length 31.75 cm (12.5 in) from probe tip to end of cable strain relief. Protection Class 3. Relates solely to insulation and grounding properties defined in IEC 348.

Measurement Considerations Instrument Compatibility The 80PK-22 is compatible with any temperature-measuring instrument that accepts Type K thermocouples, has a miniature thermocouple connector, and has cold reference junction compensation. Accuracy of the temperaturemeasuring instrument must be considered along with the 80PK-22 accuracy specification to determine the overall accuracy of the combination. Temperature Limitations The probe tip of the 80PK-22 has a continuous temperature rating of 1090 C (1994 F). However the opposite end of the sheath nearest the handle should not be subjected to temperatures greater than 125 C (257 F). This is the maximum temperature limitation of the handle. Media Limitations The sheath material of the 80PK-22 is Inconel, an alloy of chromium and nickel. It has excellent resistance to oxidation and corrosion at high temperatures, but it should not be used in the presence of sulfur above 537 C (1000 F). Operation Use the 80PK-22 as follows: 1. Connect the 80PK-22 to a compatible Type K temperature measuring instrument using the miniature (0.312-inch pin spacing) thermocouple connector. 2. Turn on the measuring instrument, and select the appropriate range and scale. 3. Check the readout on the measuring instrument. With no heat or cold source applied to the tip of the probe, the measuring instrument should display the ambient (room) temperature. If the instrument does not read out properly, refer to Troubleshooting. Minimizing Thermal Shunting The 80PK-22 Immersion Probe should be inserted at least 6.35 cm (2.5 in) into the environment to be measured to minimize the shunting effect of the sheath. Troubleshooting With no heat or cold applied to the probe, the measuring instrument should display the ambient temperature. If the measuring instrument does not read out properly, try the following: 1. Verify that the temperature-measuring instrument is designed to be used with Type K thermocouples. The temperature-measuring instrument should have a yellow input connector and / or be marked with a K either on the case or on the display. 2. Check for an open circuit indicator on the measuring instrument. Some temperature measuring instruments have a built-in circuit to indicate if the connected probe is open. (All Fluke Temperature-measuring instruments have this feature.) Refer to the owners manual accompanying the measuring instrument to see if this feature is available. Short the two input pins of the measuring instrument with a piece of wire. If the instrument is functioning, it should indicate the ambient temperature.

3. If you suspect a broken connection, use an ordinary ohmmeter to read the continuity of the probe from pin to pin. The ohmmeter should read 10 ohms or less if there is continuity. Scale Conversions Use the following equation to convert C to F: ( C x 1.8) + 32 = F Use the following equation to convert F to C: ( F 32) x 0.5556 = C 8.375" (212.725 mm) Diameter:.125" (3.175 mm) Figure 1. 80PK-22 bai01f.eps Contacting Fluke For application or operation assistance, or information on Fluke products, call: USA: 1-888-44-FLUKE (1-888-443-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 For USA Service: 1-888-99-FLUKE (1-888-993-5853) Or, visit Fluke's Web site at www.fluke.com. To register your product, visit register.fluke.com

ONE YEAR LIMITED WARRANTY This Fluke product will be free from defects in material and workmanship for one year from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke s behalf. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a description of the problem. THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A. Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands 11/99