Armoured Instrumentation Cables to BS6883

Similar documents
Armoured Power and Control Cables to BS6883

Armoured Power and Control Cables to BS7917

Armoured Power and Control Cables Fire Resistant

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS

SY CONTROL FLEXIBLE PVC INSULATED, BEDDED AND SHEATHED WITH GALVANISED STEEL BRAID

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

Kerman & Kavian Cable Industries ( KCI )

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

Railway products. Edition 2014

STANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4

A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES

CIR (Crush & Impact Resistant) VFD Power Cable

GEXOL WORLD CLASS OIL & GAS CABLES

Welding Cables Rubber Insulated

MarineLine YOZp 0,6/1 kv

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

Product information. Marine, Oil & Gas.

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

CY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED

H05Z-K / H07Z-K BS EN LSZH Wire

DNVGL-CP-0400 Edition December 2015

Marine Cables General Catalogue

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

How to order. Payment options. Delivery options. Online acatalog. By phone + (44) By fax + (44)

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables

COPPER + LWL RAW CABLES

SUPERIOR MARINE CABLE SOLUTIONS

Multimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION BUILDING MANAGEMENT SYSTEMS

Medium Voltage Power Cables

FLAME RETARDANT INSTRUMENTATION CABLE. Application Standard

T E C H N I C A L D A T A for

Ship and Offhsore. Approved cables for ship- and offshoreindustry

Cables. Cables. Power. Fire Resistant WILSON CABLES PRIVATE LIMITED. Distributed By :

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

Complete, innovative cables range for shipbuilding industry

Tri-Rated Flexible PVC Equipment Wire

H07RN-F BS EN Flexible Rubber Cable

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

Selection table for flat & ribbon cables

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

UNIRAIL D RS485 and BUS cables

Installation Recommendations

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

SANS 1339:2010 Electric cables Cross-linked polyethylene (XLPE) insulated cables for rated voltages 3,8/6,6 kv to 19/33 kv

kv: medium voltage reeling cable with fibreoptics

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

Cables for Data Transmission in Industrial Automation. Fieldbus Cables Copper Cables Fibre Optic Cables

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

Power Cables and their Application

MEDIUM VOLTAGE TERMINATIONS CATALOGUE 2017

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

Cables for data transmission in industrial automation

ABOUT US ABOUT US 1 CRANE CABLES

a Nexans company Catalogue 2009

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

VSD cables in. Working with. industrial & automation applications

6419X Conduit Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

a Nexans company Catalogue 2012

FLEXIBLE MULTI CORE CABLES

P Low Voltage Catalogue Cables Australia Powering your Project

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments

Data sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft

a Nexans company Catalogue 2012

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

HYDROFIRM(T) EMV-FC S1BC4BF KTW/W270 Drinking Water Application, shielded version ENERGY. Exclusive Authorised UK Distributor

HYDROFIRM (T) Cables. for use in Ground Water and Drinking Water

INTERNATIONAL STANDARD

NETWORK CONNECTIVITY SYSTEMS

MEDIUM VOLTAGE TERMINATIONS CATALOGUE 2017

Nexans Network Solutions Div. Euromold

C400-NMTM-1M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

C400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

SUBMERSIBLE PUMP CABLES

C195-SMQM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

Notes 3 Explanatory Information 4-10

Instrumentation Cable PLTC/ITC and TC Types

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C

To keep your family safe and protected V-Guard Wires & Cables

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

14 AWG 2 AWG: 600 Volt

The Quality Connection. Cable and Systems for Rolling Stock Business Unit Rolling Stock

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

C400-TMTM-30-X. Jumper Assembly Sample Label. Product Classification. General Specifications. Electrical Specifications

SPEC 44. Wire and cable

The Quality Connection. ICON Product Guide

Resistance Thermometers Model Series TR7X0, Sheathed Design

Transcription:

Armoured Instrumentation Cables to BS Low Smoke Zero Halogen Pairs/Triples - Collectively Screened. TAC, EPR, SCRN, SW, GSWB, SW 0/0V Application Armoured control and instrumentation cables for fixed wiring on ships and in mobile offshore units (e.g. drilling rigs, oil platforms, etc.). For use in regularly occupied areas such as accommodation facilities, control rooms and computer suites. Any application where life may be endangered by smoke and noxious fumes and where vital, sensitive equipment may be damaged by acid forming gases. Specifications In accordance with BS. Conductor: Tinned annealed copper. Stranded Class or flexible Class to BS EN 0. Insulation: EPR complying with BS GP. Core Identification: Black and white pairs. Triples black, white and red. Screening: Aluminium mylar tape in contact with tinned copper drain wire. Inner Sheath: Will be the same material as the outer sheath, based on the requirements of BS section. Type SW with improved characteristics. Enhanced oil resistance, low smoke zero halogen, minimum tear resistance. Armour: Galvanised steel wire braid to BS EN -1. Outer Sheath: As inner sheath. Identification legend will include manufacturers name, voltage, BS, number of pairs/triples and c.s.a, cable sheath class (e.g. SW) and IEC 0 and UK00A code where applicable. Standard sheath colours are grey, blue or black. Other colours available on request. Oxygen index >%, temperature index 0 C, HCL emission <0.% of weight of compound at 00 C. Flame retardant to IEC0-- Category A (reduced propagation). Temperature Rating: 0 C maximum conductor operating temperature. Voltage Rating: 0/0V. 0

Armoured Instrumentation Cables to BS Low Smoke Zero Halogen Pairs/Triples - Collectively Screened. TAC, EPR, SCRN, SW, GSWB, SW 0/0V Anixter Number UK00A Nominal Nominal Number of Diameter Over Min Max Approx Anixter No Anixter Code Cond Cond Pairs/ Inner Sheath O/D O/D Weight Prysmian Number Area Stranding Triples Min Max E1XF Hawke mm #/mm mm mm mm mm kg/km Gland Gland Multipair E1BP-E1XF E1DZ-UNI AFK-00F-D-0 KGH00 0. /0. P.0..1. -0-0 AFK-00F-D-0 KJH00 0. /0. P.0..1. -0-0 AFK-00F-D-0 KGJ00 0. /0. P.0. 0..1 0 - - AFK-00F-D-0 KJJ00 0. /0. P.0. 0..1 0 - - AFK-0F-D-0 KGK00 0. /0. P 1...0.1 0 - - AFK-0F-D-0 KJK00 0. /0. P 1...0.1 0 - - AFK-00F-D-0 KGL00 0. /0. 0P.... -0-0 AFK-00F-D-0 KJL00 0. /0. 0P.... -0-0 AFK-0-D-## - 1. /0. 1P.... -0S -0S AFK-00-D-## - 1. /0. P.... 0 - - AFK-00-D-## - 1. /0. P..0. 0. - - AFK-00-D-## - 1. /0. P..1.. - - AFK-00-D-## - 1. /0. P.0... - - AFK-0-D-## - 1. /0. P.... - - AFK-0-D-## - 1. /0. P.0. 1.0. -0-0 AFK-00-D-## - 1. /0. 0P 1...1 1. -0S -0 Multi-triple AFK-0T-B-## - 1. /0. 1TR.... 0-0S -0S AFK-00T-B-## - 1. /0. TR.... 0 - - AFK-00T-B-## - 1. /0. TR.1..0.0 - - AFK-0T-B-## - 1. /0. TR.... -0S -0 ## For black outer sheath insert suffix -0, for blue outer sheath insert suffix -0, for grey outer sheath insert suffix -0. For further technical information refer to page :. 1 0

Technical Information 0/0V EPR and MICA/EPR Insulated Cables to BS/BS Armoured and Non-Armoured CABLE TYPES: EPR insulated 0/0V instrumentation cable. MICA/EPR insulated 0/0V instrumentation cable. ELECTRICAL CHARACTERISTICS Electrical Characteristic Unit Flame Retardant EPR Insulated Conductor Size (mm ) Type Fire Resistant MICA/EPR Insulated Conductor Size (mm ) 0. 1.0 1. 0. 1.0 1. Maximum d.c. conductor resistance @ 0 C ohms/km...... Maximum a.c. conductor resistance @ 0 C ohms/km...... Maximum LOOP self-inductance (up to 1kHz) mh/km 0.0 0. 0. 0. 0. 0. Maximum L/R ratio µh/ohm 1.0.0.0.0.0 0.0 Maximum mutual capacitance: Cable Cables with collective screen only (except one pair, one triple & one quad) pf/m 0 One pair collectively screened and all cables with individually screened pairs pf/m 1 One triple/quad collectively screened and all cables with individually screened triples/quads pf/m 1 1 1 0 Resistances for 0.mm (/0.mm) and 1.0mm (/0.mm) Class conductors will be as follows: 0.mm 1.0mm Maximum d.c. conductor resistance @ 0 C ohms/km. 0. Maximum a.c. conductor resistance @ 0 C ohms/km..0 0

Cables described in this section should not be installed at temperatures below minus C, nor in any situation where the cooling air temperature exceeds C. The cables meet the IEE requirement concerning impervious sheathing for cables installed on decks, exposed to weather, in damp or wet situations, in machinery compartments and in general, where water condensation or harmful vapours (including oil vapour) may be present. The sheathing compounds will withstand normal handling, installation and service but in areas where mechanical stress is envisaged unarmoured cables should be fitted in pipes or conduit or trunking. Alternatively, armoured and sheathed cables should be used. Cables should be protected from avoidable risks of mechanical damage and routed away from heat sources such as boilers, hot pipes and resistors. Cable runs should be selected to avoid action from condensed moisture or drips. Cables should not be installed across expansion joints, but where this is unavoidable a proportioned loop of cable should be arranged, suitably supported and having an internal radius not less than twelve times its diameter. For services with duplicate supplies, the cables should Installation Guide for Offshore Cables General Precautions follow different paths and be separated as far apart as is reasonably practical. Cables and wiring for mains and emergency power, lighting, internal communications or signalling should be routed away from galleys, machinery spaces and other high fire-risk areas except when supplying equipment in those places. In situations offering considerable risk of mechanical damage, such as storage spaces, cables should be protected by steel casing, trunking or conduit if the structure or attached parts do not afford sufficient protection, even to armoured cables. Any metal casing so used should be sufficiently protected against corrosion. All cable supports and accessories should be robust and constructed from corrosion-resistant material, or suitably treated to resist corrosion. Metals or alloys with low melting points (e.g. aluminium) should not be used. Cables passing through watertight decks or bulkheads should be provided with deck-tubes, watertight glands, multi-transit assemblies, or fire-retardant packed boxes as appropriate to meet the requirements of the Authority approving the installation. 1 0

Installation Guide for Offshore Cables General Precautions Where cables pass through non-watertight bulkheads, beams or other steel structure, the holes should be glanded or bushed with non-corroding materials to prevent damage to both cables and structure. The means of fixing of conductors and terminals should be capable of withstanding the thermal and dynamic effects of short circuits. When single core cables, having a current rating greater than 0A need to be installed close to a steel bulkhead, the clearance between cable and metal surface should be at least 0mm, unless the cables belonging to the same a.c. circuit are installed in trefoil. In the interests of safety and circuit reliability, it is assumed that installers will adhere to the IEE Regulations and Recommendations for the Electrical Equipment of Ships and of Mobile and Fixed Offshore installations. Particular attention should be paid to recommendations concerning cables, with regard to their effect on navigational and radio equipment. MINIMUM BENDING RADIUS Ideally cables should be bent as little as possible and never to radii less than the following: Type of Cable* Minimum Bending Radius Instrumentation x diameter Power & Control up to./. kv ** Armoured up to mm D x diameter Armoured over mm D x diameter Unarmoured up to mm D x diameter Unarmoured over mm up to mm D x diameter Unarmoured over mm D x diameter Power cable./. kv and above ** Un-screened x diameter Screened - single core 0 x diameter Screened - three core x diameter * All fire survival (FS) cables - x diameter. ** x diameter Class flexible cables. 0