FA Wireless SS Terminals

Similar documents
Name Number of I/O points (words used) Model Antenna style. 512 outputs max. (32 words) Magnetic Base Antenna (1) --- WD30-AT001 (See note.

NPN PNP NPN PNP NPN PNP

Phase-sequence Phase-loss Relay

High-speed, wireless communication with easy installation and simple wiring!! *Antenna sold separately. 250 m range. Antenna with cable available

Single-phase Voltage Relay


Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

CompoBus/D-type Digital Controller

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

Digital Amplifier Ultrasonic Sensor E4C-UDA Series

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

Safety Relay Unit. OFF-delay time

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

onlinecomponents.com

SPST-NO SPDT DPST-NO DPDT

Count/Time Totalizers

CompoNet Gateway Unit for CC-Link

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) E3C-LDA Series

Single-phase Current Relay

Supply voltage Output configuration Resolution (P/R) Model 12 to 24 VDC Complementary output 100, 200, 360, 500, or 600 E6F-CWZ5G 1,000

Distance-setting Photoelectric Sensor

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Model Number Structure

Self-powered Counter

Model Number Structure

Model Number Structure

High-precision Optical Switch

Multipoint Temperature Controller

New Product News. Programmable Digital Controller E5AR-T/E5ER-T. One Digital Controller with Up To 32 Programs

4 channels High Speed Counter Unit

Solid-state Timer H3DS

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

LENORD. +BAUER... automates motion. Magnetic absolute rotary encoder GEL 2037 with heavy duty flange or tooth wheel adapter

Multi-point Temperature Controller

Distance-setting Photoelectric Sensor

Process Meter. Applicable

Solid-state Twin Timer

Label Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor

Field Network SRT Series

Fuzzy Temperature Controllers E5AF

Absolute Rotary Encoder

Ordering Information. Ratchet Relay G4Q. Model Number Legend

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

E3Z-LS. Distance-settable Photoelectric Sensor. Ordering Information. Sensors. Accessories (Order Separately)

Class II. Sensing method Appearance Connection Sensing distance Output function Model method NPN output PNP output mm.

2-channel speed sensor GEL 247 Compact sensor for harsh applications

Temperature Controllers E5 J

A 2 W A 2 W Model Number Structure A2W. Model Number Structure Slave button.

V700-series. Electromagnetic Inductive RFID System. ID Tag. Antenna. Controller

Model Number Structure

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

Connections Appearance Sensing method Sensing distance Operating mode Model Plug-in connector Horizontal Through-beam 30 m Light-ON

Correction Reissue. Product Discontinuation Notices

Features. Panel Meters with Advanced Signal Processing Capabilities K3HB

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models

Z500. High-Precision Sensor that Measures and Displays an Object's Profile. Profile Measuring System

FINAL DRAFT TECHNICAL REPORT CLC/FprTR RAPPORT TECHNIQUE TECHNISCHER BERICHT January English version

SPST-NO SPDT DPST-NO DPDT

Model Number Structure

Built-in Amplifier Photoelectric Sensor

Rated time Time setting range Time division 1 week 00:00 a.m. to 11:59 p.m. 1 min

Surface-mounting Relay

Coaxial Switch. Ordering Information. High-frequency, High-capacity Coaxial Switch Supporting Bandwidth to 26.5 GHz. Model Number Legend:

Remote Sensor Amplifier Terminal

Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.

Inductive Proximity Sensor

APPENDIX APPENDIX A 1

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9853E 2-Port, High-Speed CAN Module

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view

WIRELESS MODBUS GATEWAY WGW410

FP-RLY-420. Features. Installing the FP-RLY-420. FieldPoint Operating Instructions. Eight-Channel SPST Relay Module

E3S-CL. Distance setting photoelectric sensor in metal housing. Features

Digital Indicators K3HB Series

E2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately)

Details on the New G2RS

Power supply voltage Output configuration Output code Resolution (pulses/rotation) Connection method Model

The compact test- disconnect terminal interface system for protection and secondary technology

FP-DO-400 and cfp-do-400

General Specifications

E3S-CR62/67. Ideal for detecting transparent glass and plastic containers. Transparent bottle sensor. Features

Ultrasonic Displacement Sensor E4DA

PRODUCT DATA. Sound Intensity Calibrator Type 4297

Solid-state Timer H3DE

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

A new approach to static electricity countermeasures

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view

Process Control HPP-25

Inductive Proximity Sensor

MODEL: WL40MW1F. Wireless I/O WL40F Series

Select G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X Cartridges

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

General Specifications

Process-Controller HPP-25

PCB Relay. --- G2R-1-SN --- G2R-2-SN LED indicator with test

MOS FET Relay. Ordering Information. SSR for Switching Analog Signals, with an Insulation Value of 2.5 kvac between Input and Output Terminals

Ordering Information. Application Example. New General-purpose Incremental. Rotary Encoder

Transcription:

FA Wireless SS Terminals WT30 Construct a Wireless System for ON/OFF Data Collection That Is Ideal for Monitoring Production Site Equipment Wireless Slave Station equipped with I/O. Height of 90 mm and DIN Rail mounting enables installation in control panels. Easily check wireless communications status from indicator display. I/O Slave Stations can also be used as Slave Stations in WD30 systems. Conforms to radio wave standards for Japan, China, USA, and Europe. Ordering Information List of Models Wireless Unit model Type Specifications/No. of I/O points WT30-M01-FLK Serial master RS-232C WT30-SID16 I/O slaves 16 DC inputs (NPN/PNP) WT30-SMD16 8 DC inputs (NPN/PNP) + 8 transistor outputs (NPN) WT30-SMD16-1 8 DC inputs (NPN/PNP) + 8 transistor outputs (PNP) Note: An Antenna and Mounting Brackets are not included with the Wireless SS Terminal. Accessories Antennas Model WT30-AT001 WT30-AT002 WT30-AT003 Communications Cables Other Type Magnet-base Antenna (2 antennas per set) Flat Diversity Antenna (1 antenna) Pencil Antenna (2 antennas per set) Model Length Application XW2Z-0100U-3 1 m For personal computer XW2Z-0200U-3 2 m XW2Z-0500U-3 5 m XW2Z-0200U-5 2 m Cross cable for PLC XW2Z-0500U-5 5 m Model WT30-FT001 WT30-FT002 WT30-FT003 Type DIN Rail Mounting Bracket (for TH35-7.5) DIN Rail Mounting Bracket (for TH35-15) Surface Mounting Bracket (screw-mounting) (2 brackets per set) WT30-FT011 Flat Diversity Antenna Mounting Brackets (with magnets) WT30-CA2M Antenna Extension Cable (1 cable, 2 m) Conformity to Wireless Standards in China Wireless channels 1 and 51 cannot be used in China. Use the channels between 2 and 34 and between 52 and 83. Also, use of the product on board aircraft and in the vicinity of airports is prohibited. Only the WT30-AT001 Magnet-base Antenna can be used in China. All other Antennas are not applicable. Applicable Standards FCC part 15.247 (USA) EN 300 440-2 (Europe) ARIB STD-T66 (Japan) (China) Conformity to Safety Standards Always use a Class 2 power supply to conform to UL standards. Main Class 2 Power Supplies OMRON Switching Power Supplies S8VS (15 W, 30 W, 60 W type) S82K (15 W, 30 W, 50 W, 90 W type) Conformity to EN Standards Use a DC power line less than 3 m to conform to EN standards. If a power line of 3 m or longer is required, extend the length at the Switching Power Supply s primary side (i.e., the AC power line). Applicable Countries Wireless standards have been met for the following countries. The product cannot be used in any other countries. Austria, Belgium, China, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungry, Iceland, Ireland, Italy, Japan, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland, UK, USA FA Wireless SS Terminals WT30 1

Specifications Ratings Power supply (wireless communications power supply) Error output/output power supply (for output circuits) Insulation resistance Dielectric strength Noise immunity Vibration resistance (See note 2.) Shock resistance Ambient operating temperature Note: 1. Provide a power supply of at least 15 W, considering the inrush current generated at startup. 2. Use the WT30-FT003 Surface Mounting Bracket when installing the WT30 in environments subject to vibration. Wireless Interface Specifications Note: Varies according to the installation environment. Package Contents WT30 FA Wireless SS Terminal Instruction Sheet Item WT30-M01-FLK Serial Master WT30-SID16/SMD16/SMD16-1 I/O Slaves Rated voltage 24 V DC Allowable voltage 20.4 to 26.4 V DC range Power consumption 3 W max. (See note 1.) Rated voltage --- 24 V DC Allowable voltage --- 20.4 to 26.4 V DC range 20 MΩ min. (at 100 V DC) between the power supply and chassis 1,500 V AC for 1 min between power supply and chassis IEC61000-4-4. 1 kv (power supply line) Terminal labels (I/O Slaves only) Adhesive non-slip feet (Serial Master only) 20 MΩ min. (at 100 V DC) between the power supply and all I/O and I/O power supply and between the power supply and chassis 1,500 V AC for 1 min between the power supply and all I/O and I/O power supply and between the power supply and chassis JIS C0040 Frequency: 10 to 55 Hz; Amplitude of 0.35 mm or acceleration of 50 m/s 2, whichever is smaller (DIN Rail mounting: single amplitude of 0.1 mm or acceleration of 15 m/s 2 ) 10 sweeps of 8 min each (i.e., 80 min in total) in X, Y, Z directions Conforms to JIS C0041: 300 m/s 2 3 times each in X, Y, and Z directions 10 to 55 C (with no condensation or icing) (with the Terminal mounted with the dust-proof label facing up) Number of simultaneously ON I/O points 10 max.: 10 to 55 C (with no condensation or icing) 16 max.: 10 to 50 C (with no condensation or icing) (with the Terminal mounted with the dust-proof label facing up) Ambient operating humidity 25% to 85% (with no condensation or icing) Ambient environment No corrosive gases Storage temperature 25 to 65 C (with no condensation or icing) Protective structure IP20 Terminal construction Power supply and I/O Screwless terminal block (Phoenix Contact FFKDS/V1-5.08 or equivalent) Serial D-sub, 9-pin (female) Inch screws (OMRON XM2F-0910-132 or equivalent), Master station only --- Safety standards Weight Item Wave type Communication method Frequency band Number of channels Transmitter output power Baud rate between wireless stations Communications distance (See note.) Error detection method Relay functions Number of stations per area (See note.) Number of I/O Slaves connected UL: UL508 (Listing) 330 g max. Spread Spectrum (direct sequence; DS-SS) Simplex 2,401 to 2,480.2 MHz 67 channels (based on switching) 10 mw/mhz 100 kbps Specifications Indoors: 60 m min. (approx. 50 m min. with Magnet-base Antennas and Flat Diversity Antennas) Outdoors: Approx. 300 m min. (anticipated distances) (without using relay stations) CRC-CCITT (16 bits) One stage using I/O slave for the serial master configuration. 10 sets max. (recommended) 64 max. 2 FA Wireless SS Terminals WT30

Nomenclature Serial Master Station Antenna terminal (ANT1) Status indicators Unit No. switch Set the unit number of the Serial Master Station. Node setting switch (WNODE) Set the number of connected I/O Slave Stations. Channel setting switch (WCH) Set the communications frequency channel. Antenna terminal (ANT2) Received signal strength indicator Special function switch Unit No. Switch Set the unit number of the Serial Master Station. Default: 00 Node Setting Switch (WNODE) Set the number of connected I/O Slave Stations. Set the node number of the Slave Stations being used as I/O Slave Stations. The Slave Station functions as a relay station when the node number is set to 99. Default: 01 Channel Setting Switch (WCH) Set the communications frequency. Default: 02 Function Setting Switch Serial Master Station Mode selection switch Switch between RUN, TEST, and SET mode. Power supply terminal Supply power to the WT30. I/O Slave Station Antenna terminal (ANT1) Status indicators Mode selection switch Switch between RUN, TEST, and SET mode. Power supply terminal Supply power to the WT30 and output circuits. Function setting switch Make the detailed settings for RUN/TEST/SET mode. RS-232C Terminal Connect the PLC, personal computer, etc. Serial communications setting switch Set the baud rate. I/O terminals Connect the contact signals. Node setting switch (WNODE) Set the unit number of the I/O Slave Station. I/O terminal status indicators (0 to 7 or 8 to 15) The contact status is displayed. Channel setting switch (WCH) Set the communications frequency. Antenna terminal (ANT2) Received signal strength indicator Special function switch Function setting switch Make the detailed settings for RUN/TEST mode. No. Applicable mode ON functions 1 RUN mode Holds I/O status data when a communications error occurs. I/O Slave Station OFF functions Clears I/O status data when a communications error occurs. 2 Enable scan list Disable scan list 3 Relays used Relays not used 4 TEST mode Signal strength monitor disabled Signal strength monitor enabled 5 All channels Specified channels automatically switched 6 --- --- 7 SET mode Scan list recognition Nothing done 8 Registers specified I/O slave 9 Recognizes serial numbers 10 Not used --- --- No. Applicable mode ON functions 1 RUN mode Holds I/O status data when a communications error occurs. Registers all I/O slaves automatically Ignores serial numbers OFF functions Clears I/O status data when a communications error occurs. 2 Input hold Normal mode 3 Input filter: 100 ms Input filter: 10 ms 4 TEST mode Signal strength monitor disabled Signal strength monitor enabled 5 All channels Specified channels automatically switched 6 Installation test Nothing done function 7 to 10 Not used --- --- FA Wireless SS Terminals WT30 3

Serial Communications Setting Switch No. Function ON OFF 1 Communications setting selection Detailed settings (settings for No. 2 to 8 used) 2 Baud rate (bps) 1 0 3 (See note.) 2 0 4 Total value = 0: 1,200 = 1: 2,400 = 2: 4,800 = 3: 9,600 = 4: 19,200 = 5: 38,400 = 6: 57,600 = 7: 115,200 4 0 5 Data length 8 bits 7 bits 6 Parity None Yes 7 Odd Even 8 Stop bits 1 bit 2 bits Default settings (baud rate: 9,600 bps; data length: 7 bits; parity: even; stop bits: 2) Settings for No. 2 to 8 are ignored. Note: For example, if pins number 2, 3, and 4 are all ON, the total is 7, which corresponds to a baud rate of 115,200 bps. Display Indicator Color Status Meaning (primary error) PWR Green Lit Power is being supplied. Not lit Power is not being supplied. ERR (Slave Station) COMM (Master Station) 0 to 15 (Slave Station) RSSI MS (Module Status) WS (Wireless Status) Red Lit Error output is ON: Wireless device error or wireless communications error. (See note) Not lit No wireless device error or wireless communications error. Yellow Lit Serial communications in progress. Not lit No serial communications. Yellow Red/ Yellow/ Green Lit/Not lit ON/OFF status for input or output signals Lit/ All not lit Receiving Signal Strength Indicator monitor: Number of indicators lit (receiving signal strength 1 to 9) Receiving signal strength less than 0 to 1. Green Lit Communications are normal. Flashing TEST mode or SET mode has been activated. Red Lit A fatal error has occurred that cannot be recovered from. Replace the Unit Flashing A non-fatal error has occurred that can be recovered from by resetting the system. --- Not lit Power is not being supplied or the system is resetting. Green Lit The station has joined the wireless network. Flashing Permission to join wireless network received from Serial Master Station (Slave Station) Red Lit A fatal error has occurred that cannot be recovered from. Flashing Error from which recovery is possible --- Not lit Wireless communications are not in progress. Note: When using the WD30 as the Serial Master Station, the ERR indicator will light if normal I/O communications are not possible due to an error in the host network. 4 FA Wireless SS Terminals WT30

Wiring Serial Master Station (WT30-M01-FLK) WT30 Power supply terminal Supply power to the Unit RS-232C Connector 54321 9876 D-sub, 9-pin, Female End at WT30 Pin No. Signal I/O direction 1 --- --- 2 RD Output 3 SD Input 4 --- --- 5 SG --- 6 --- --- 7 --- --- 8 --- --- 9 --- --- I/O Characteristics I/O Slave Station WT30-SID16 Error output power supply Inputs Inputs IN V G 0 1 2 3 COM 4 5 6 7 COM ERRP 24 V DC 0 V 8 9 10 11 COM 12 13 14 15 COM ERRN IN Power supply Inputs Inputs WT30-SMD16 WT30-SMD-16-1 Error output/output power supply Inputs Inputs Error output (PNP) Error output (NPN) Error output (PNP) IN V G 0 1 2 3 COM 4 5 6 7 COM ERRP Input Characteristics Output/Error Output Characteristics Item Specifications Input voltage 24 V DC Allowable 20.4 to 26.4 V DC voltage range Input 4.7 kω (typical) impedance Input current 5 ma (typical) ON voltage/ 17.4 V DC, 3.0 ma min. current characteristics OFF voltage/ current characteristics Input filter Input voltage Allowable voltage Max. switching current Leakage current Residual voltage 5.0 V DC, 1.0 ma max. 10 ms/100 ms (Selected using switch.) 24 V DC 20.4 to 26.4 V DC 100 ma max. per output (at 20.4 to 26.4 V DC) Simultaneous usage of error output NPN/PNP is not possible. 0.1 ma max. 1.0 V max. One for every two outputs except for error output circuits, which have one for every NPN/ PNP output. (No fuses can be replaced by the user.) 24 V DC 0 V 0 1 2 3 COM 4 5 6 7 COM ERRN OUT Power supply Outputs Outputs Error output (NPN) FA Wireless SS Terminals WT30 5

Input Circuit Diagram Output Circuit Diagram (NPN) IN 0 V OUT 0 Secondary internal circuit IN 1 IN 2 IN 15 COM (IN) Secondary internal circuit OUT 1 OUT 2 OUT 7 G Error Output Circuit Diagram Output Circuit Diagram (PNP) V V OUT 0 Secondary internal circuit ERRP ERRN Secondary internal circuit OUT 1 OUT 2 OUT 3 G OUT 7 G Dimensions Note: All units are in millimeters unless otherwise indicated. Serial Master Station WT30-M01-FLK I/O Slave Station WT30-SID16 WT30-SMD16 WT30-SMD16-1 13.3 105 13.3 105 (15) 120 Four, 5 dia. 60 40 90 (15) Surface mounting bracket WT30-FT003 7.3 DIN rail mounting bracket WT30-FT001 or WT30-FT002 6 FA Wireless SS Terminals WT30

With Magnet-base Antenna WT30-AT001 (34) With Flat Diversity Antenna WT30-AT002 (23) With Pencil Antenna WT30-AT003 150 40 (46) (46) R38 R40 R50 20 (32) 4.6 (38) Serial Master Station Surface Mounting Bracket WT30-FT003 I/O Slave Station DIN Rail mounting bracket WT30-FT001 or WT30-FT002 I/O Slave Station DIN Rail mounting bracket WT30-FT001 or WT30-FT002 Magnet-base Antenna WT30-AT001 Flat Diversity Antenna WT30-AT002 Pencil Antenna WT30-AT003 26 57.5 Three, 3 dia. 57.5 52 75 115 10.5 dia. 10.5 dia. 2010 35.8 dia. 39 2010 DIN Rail Mounting Bracket WT30-FT001 WT30-FT002 Surface Mounting Bracket WT30-FT003 Flat Diversity Antenna Mounting Brackets (with magnets) WT30-FT011 FA Wireless SS Terminals WT30 7

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. N139-E1-02 OMRON Corporation Industrial Automation Company In the interest of product improvement, specifications are subject to change without notice. Control Devices Division H.Q. Network Devices Department Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7116/Fax: (81)75-344-8197 Printed in Japan 0805