Instruction Manual ICM 135R Electrical Clamp Multimeter EN FR IT DE ES

Similar documents
ICM 136R Operating Instruction Electrical Clamp-Multimeter

Instruction Manual ICM A9 Electrical Clamp Multimeter EN FR IT DE ES

Instruction Manual IDM 61/62T Digital Multimeter EN DE ES IT FR

Instruction Manual IDM 66RT Digital Multimeter

Instruction Manual IDM 98-III & IDM 99-III Digital Multimeters

IDM 98-III & IDM 99-III Digital Multimeters

INSTRUCTION MANUAL IDM17 PEN-TYPE MULTIMETER

IDM 503 & 505 Digital Multimeters

Instruction Manual IPM φ/1φ Power Clampmeter EN FR IT DE ES

Safety Information. WARNING Identifies hazardous conditions and actions that could cause BODILY HARM or DEATH

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

IDM 61/62T Instruction Digital Multimeter Manual

312, 316, 318. Clamp Meter. Users Manual

374/375/376 Clamp Meter

600A Clamp Meters w/tightsight Display

Electrical Multimeter

374/375/376 Clamp Meter

netzerotools.com 374/375/376 Users Manual Clamp Meter

323/324/325 Clamp Meter

374 FC/375 FC/376 FC Clamp Meter

Instruction Manual IDM 103N/105N/106N Digital Multimeter EN FR IT

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Instruction Manual IDM 503 & IDM 505 Digital Multimeters IDM 505

NOTE: Fully read and understand this manual before using this Digital Multimeter.

BENNING. CM7 Electrical Tester. Service Information

User Manual. Solar Power Clamp. 99 Washington Street Melrose, MA Phone Toll Free

36 AC/DC True RMS. Clamp Meter. P Read First: Safety Information

Instruction Manual. IM Axis RF Field Strength Meter

# Digital Multimeter

79/26 Series III Multimeter

INSTRUCTION MANUAL UTL260

CT238A. AC/DC Current Probe. User Manual. For detailed specifications and ordering info go to

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

12B/18 MultiMeter Instruction Sheet

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

LH630 LH635 LH1035. Operating Instructions Mode d emploi Bedienungsanleitung Istruzioni per il funzionamento Instrucciones de Funcionamiento

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

MS2030 CAT III 600 V A V AUTO RS232

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

AMP-25 AMP-25-EUR. Mini-Clamp TRMS AC / AMP-25. ZERO 2 Sec

AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325

200Amp AC Clamp Meter + NCV Model MA250

374/375/376. Calibration Manual. Clamp Meter

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

80i-110s. AC/DC Current Probe Instructions. Introduction

Instruction Manual IDM 103N/105N/106N Digital Multimeter EN FR IT

USER'S MANUAL TBM061 TBM062 TBM063 TBM065

User Manual Digital Clamp Multimeter. model no.: MSR-C600

LH240 LH1040 LH2040 LH2015

User Guide. Digital AC/DC Clamp Meter Model 38394

AM-500 Autoranging Mulitmeter. AM-500-EUR Digital Multimeter. Users Manual

Digital Clamp Meter Model: &

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

User s Guide. Digital AC/DC Clamp Meter Model 38394

AC/DC CLAMP METER USER S MANUAL

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

374/375/376 Clamp Meter

Electrical Multimeter

User s Guide. 400A AC/DC Clamp Meter. Model MA220

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

DM-45 Digital Multimeter

Pen Multimeter. Model

CONTENTS MS2033A. 1.Introduction Safety Information...01

NI 71/72. Multimeter. Manual

ET-3888 True RMS Clamp Meter. User Manual

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

Autoranging Multimeter Extech EX503

User's Manual. Clamp-on Power Datalogger. Model

902 FC. HVAC True-rms Clamp Meter

AC68C. Users Manual. True RMS AC/DC Clamp Multimeter. PN July Amprobe Test Tools. All rights reserved.

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

15B & 17B. Users Manual. Multimeters

374/375/376 Clamp Meter. Users Manual

Instruction Manual ET4 ELECTRICAL TESTER

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL- KM 2782 / 2782-T

UT207A/208A/209A Operating Manual. Table of Contents

For detailed specifications and ordering info go to

User s Guide. Model MA A AC Mini Clamp-on Meter

Instruction Manual IDM207 Digital Multimeter

T+ and T+ PRO Electrical Tester

USER'S MANUAL DMR-6700

Models 110, 111 & 112

User Manual. APPA 130 Serise

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

DIGITAL CLAMPMETER MODEL

Circuit Breaker Finder

OPERATOR S INSTRUCTION MANUAL

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Dawson DDM190. Digital Multimeter User s Manual

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

DM-46 Instruction Manual

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

Transcription:

Instruction Manual ICM 135R Electrical Clamp Multimeter EN FR IT DE ES

Safety Information For safe operation of this clamp-multimeter, read these instructions completely before you use it and comply with them fully. Failure to observe these warnings can result in severe injury or death. - If possible, do not work alone, so assistance can be given if required. - Do not use the clamp-multimeter or test-leads if they are damaged. - Do not use the clamp-multimeter if it is not operating correctly, or if it is wet. - Use the clamp-multimeter only as specified in these Operating Instructions, or the protection provided by it may be impaired. - Use extreme caution and wear Personal Protective Equipment when taking measurements where Hazardous Live parts could be Accessible. - Use caution when measuring or working near voltages above 30 V ac rms, or 60 V dc. These voltages may cause a shock. - Do not allow fingers to protrude beyond the Tactile Barrier when fitting or removing the instrument from around a Hazardous Live conductor, as this may cause a shock. Symbols as marked on the Clampmultimeter and instructions Risk of electric shock Refer to operating instructions. DC measurement Equipment protected by double or reinforced insulation Battery Earth AC measurement Conforms to EU directives May be used on uninsulated Conductors. 2

Caution If the clamp-multimeter is used in the vicinity of equipment which generates electromagnetic interference, the display may become unstable or the measurements shown may be subject to large errors. TEST EQUIPMENT RISK ASSESSMENT Users of this equipment and or their employers are reminded that Health and Safety Legislation require them to carry out valid risk assessments of all electrical work so as to identify potential sources of electrical danger and risk of electrical injury such as from inadvertent short circuits. Where the assessments show that the risk is significant then the use of fused test leads constructed in accordance with HSE guidance note GS38 Electrical Test Equipment for use by Electricians should be used. Maintenance Do not attempt to repair the clampmultimeter. It contains no user-serviceable parts. Contact RS Components for repair, servicing or calibration of this clampmultimeter. The address is given at the end of these instructions. Cleaning To clean the clamp-multimeter, use a damp cloth moistened with a weak detergent solution. Do not use abrasives or solvents. 3

Power On / Off Auto Power Off 30min Auto Power Off disable : Press any button (except the Hold button), or rotate the rotary switch to reset the Auto Power-Off function and turn the clamp-multimeter on. 4

AC V / DC V Resistance 5

Continuity ACA 190A CAT.Ⅲ.600V with respect to earth for the jaw. Tactile Barrier for hand guard Do not hold the meter across the Tactile Barrier I OK I I I I+(-I)=0 6

Hz ACA 50Hz Data Hold 190A 0A 7

Min / Max Hold MAX: The clamp-multimeter stores the maximum and minimum values. The maximum value is displayed. MIN: The clamp-multimeter stores the maximum and minimum value. The minimum value is displayed. MAX MIN (flashing): The clamp-multimeter stores the maximum and minimum values. The present value is displayed. Normal: Press and hold the MIN MAX button to return to normal operation. Battery Replacement Warning : Disconnect the clampmultimeter from all power sources and remove it from around a conductor before removing the battery compartment cover. Replace battery: Replace the battery when the low battery symbol appears on the display. 8

Peak Hold P MAX : The clamp-multimeter stores the peak maximum and minimum values. The peak maximum value is displayed. P MIN : The clamp-multimeter stores the peak maximum and minimum values. The peak minimum value is displayed. CAL: Press and hold the PEAK button >3 sec to calibrate the clamp-multimeter for accurate measurement. Normal: Press and hold the PEAK button to return to normal operation. Back Light The back-light will automatically turn off after approximately 60 seconds. 9

Specifications 1-1 General Specifications LCD display : 4000 counts, 3 3/4 digit LCD readout. Measuring rate : 1.5 times / sec. Overrange display : OL is displayed for Ω functions, Actual value is shown for A and V function. Automatic power off time : Approximately 30 minutes after power on. Low battery indicator : is displayed. Power requirement : 9V battery type 6LR61 (IEC) Alkaline. Battery life : ALKALINE 9V ; 200 hours. 1-2 Environmental Conditions Indoor Use only. Calibration : One year calibration cycle. Operating temperature : 0 C ~ 30 C ( 80% RH) 30 C ~ 40 C ( 75% RH) 40 C ~ 50 C ( 45%RH) Storage temperature : -20 to +60 C, 0 to 80% RH (batteries not fitted). Overvoltage category : IEC 61010-1 600V CAT.Ⅲ. CAT.Ⅲ equipment is designed to protect against the transients in the equipment in fixed installations, such as distribution panels, feeders and short branch circuits and lighting systems in large buildings. Operating altitude : 2000m (6562 ft) Conductor Size : 34mm diameter. Pollution degree : 2 EMC : EN 61326-1 Shock vibration : Sinusoidal vibration per MIL-T-28800E (5 ~ 55 Hz, 3g maximum). 10

1-3 Electrical Specifications Accuracy is ± (% reading + number of digits) at 23 C ± 5 C < 80%RH. Temperature coefficient : Add 0.2 x (Specified accuracy) / C, < 18 C, > 28 C. Voltage Function Range Accuracy V 0~400.0Vrms 400~600Vrms ±(1.0%+ 5 digits) 50Hz ~ 500Hz *1 V 0~400.0 V 400~600 V ±(0.7% + 2 digits) *1: For readings of less than 15% of full scale (4000 digits), add 4 digits to reading. The settling time will be longer. Overload protection: 600 Vrms Input impedance: 1MΩ // less than 100pF. AC Conversion Type: AC Conversions are ac-coupled, true rms responding, calibrated to the rms value of a sine-wave input. Accuracies are given for sine-wave at full-scale and non-sine wave below half-scale. For non sine-wave add the following Crest Factor corrections: For Crest Factor of 1.4 to 2.0, add 1.0% to accuracy. For Crest Factor of 2.0 to 2.5, add 2.5% to accuracy. For Crest Factor of 2.5 to 3.0, add 4.0% to accuracy. CF 2 600V//600A 11

Resistance & Continuity Function Range Accuracy Ω 400.0Ω ±(1% + 3 digits) Overload protection : 600 Vrms Max. open circuit voltage : 3V Continuity check : Internal sounder activates if the resistance of the circuit under test is less than 30Ω approximately. AC Current Function Range Accuracy A (50~60Hz) A (61~400Hz) 0~60.0A 60.1~400.0A 401~600A 0~400.0A 401~600A ±(1.9% + 7 digits)*1 ±(1.9% + 5 digits) ±(2.5% + 7 diigts) *1 * 1 AC Conversion Type and additional accuracy is same as AC Voltage. Overload protection: 600 Arms Position Error: ±1% of reading. Frequency : Hz Range Accuracy 20~400Hz ±(0.1% + 2 digits) Overload protection : AC/DC 600 Arms Sensitivity : 3 Arms for ACA (A ) (>400Hz Unspecified) Peak Hold : ± (3% + 15digits) *>600Vpeak Unspecified. *>600Apeak Unspecified. The range is automatically switched to the low resolution range at Peak Hold or Min Max Hold. 12

Limited Warranty This instrument is warranted to the original purchaser against defects in material and workmanship for 3 year from the date of purchase. During this warranty period, RS Components will, at its option, replace or repair the defective unit, subject to verification of the defect or malfunction. This warranty does not cover fuses, disposable batteries, or damage from abuse, neglect, accident, unauthorized repair, alteration, contamination or abnormal conditions of operation or handling. Any implied warranties arising from the sale of this product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. The manufacturer shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expense or economic loss. Some states or countries laws vary, so the above limitations or exclusions may not apply to you. For full terms and conditions, refer to the current RS Catalogue. 13

Asia Iso-Tech 460 Alexandra Road, #15-01A PSA Building Singapore 119963 USA 7410 Pebble Drive Fort Worth Texas 76118-6961 Europe Iso-Tech PO Box 99 Corby Northamptonshire NN17 9RS United Kingdom Canada 1701 Woodward Drive Ste 108 Ottawa Ontario K2C 0R4, Canada Japan West Tower (12th Floor) Yokohama Business Park 134 Godocho, Hodogaya Yokohama, Kanagawa 240-0005 Japan South America Av. Pdte. Eduardo Frei M. 6001-71 Centro Empresas El Cortijo Conchali, Santiago, Chile