TECHNICAL SPECIFICATION FOR G. I. WIRE (4MM)

Similar documents
SECTION-I (G.I.PLAIN WIRE) TECHNICAL SPECIFICATION FOR G. I. WIRE

TECHNICAL SPECIFICATION FOR G.I. WIRE AND G.I. STAY WIRE

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM

TECHNICAL SPECIFICATION OF LT SHACKLE BOLT (G. I. BOLT) WITH NUT AND SPRING WASHER

012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)

015 : 1993 CEB STANDARD

001: 2007 CEB STANDARD

TECHNICAL SPECIFICATIONS

079 : 2000 CEB STANDARD ALUMINIUM BINDING WIRE

Indian Standard SPECIFICATION FOR USE IN FOUNDRIES. 1.1 This standard covers the requirements for chaplets for use in foundries.

Technical Specification. for 1.1 KV Copper Control Cable

DRAFT UGANDA STANDARD

BUREAU OF INDIAN STANDARDS. Draft Indian Standard TWO COMPONENTS HIGH BUILD EPOXY MICACIOUS IRON OXIDE (MIO) PIGMENTED INTERMEDIATE COAT SPECIFICATION

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

MESP TECHNICAL SPECIFICATION FOR TRANSMISSION WIRE HARD-DRAWN COPPER 19/ mm 2

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES

TECHNICAL SPECIFICATION OF STAY WIRE FOR TRANSMISSION LINES AND SUB STATIONS

Barofor Round System (polyester coated) Panels, Posts, Accessories

PWI PERFECT WIRE INDUSTRIES

NPS/001/010 Technical Specification for Fasteners and Fixings for Wood Pole Overhead Lines and General Construction Works

CMD-II (Legal) Our Ref: CMD-II (Legal)/16: Oct 2014

NORTH EASTERN ELECTRICITY SUPPLY COMPANY OF ORISSA LIMITED SECTION - III TECHNICAL SPECIFICATION OF ELECTRICAL MATERIALS GROUP B

AS Australian Standard STEEL WIRE FOR TENDONS IN PRESTRESSED CONCRETE. This is a free 5 page sample. Access the full version online.

SPECIFICATION FOR SAFETY POLE SIGNS & ACCESSORIES

SPECIFICATION FOR 11 KV CLASS, 24/15.7, 30/19.7 & 45/29.5 AMPS SPECIAL DESIGN TRANSFORMERS.

MESP TECHNICAL SPECIFICATION FOR CATENARY WIRE HARD-DRAWN COPPER 37/ mm 2

Steel wire for general fencing purposes

1 Scope. 2 Normative references. 3 Dimensions. Page 2 DIN :

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

BBD7267 Version 1 PRIEVIEW COPY ONLY

MESP TECHNICAL SPECIFICATION FOR MURL JUMPER WIRE HARD-DRAWN COPPER 19/ mm 2

MESP TECHNICAL SPECIFICATION FOR BARE FLEXIBLE ANNEALED COPPER JUMPER WIRE 37/7/ mm 2

Steel Nipples. Nipples & Fittings. Black and Galvanized Steel Nipples. Black and Galvanized. Steel Nipples. 142

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

TECHNICAL SPECIFICATION FOR. CONTACT WIRE HARD-DRAWN COPPER 161mm2

SPECIFICATION FOR HIGH STRENGTH STRUCTURAL BOLTS

SPECIFICATION FOR SINGLE-MODE OPTICAL FIBRES

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

NATIONAL POWER TRAINING INSTITUTE (WR) (Ministry of Power, Govt. of India) NAGPUR TENDER DOCUMENT SUPPLY OF DRAWING TABLES AND STOOLS

Annexure - V. Specifications, Typical Drawing & Data Sheet for Split TEE (Hot Tapping Material)

MESP TECHNICAL SPECIFICATION FOR FLEXIBLE DROPPER WIRE TIN-BEARING COPPER 7/7/ mm 2

GROUP B Details of require Materials:

RR-F-191/1D 14 May SUPERCEDING RR-F-191/1C July 22, 1981 FEDERAL SPECIFICATION SHEET

Government Recognized Export House OHSAS 18001:2007 ISO 14001:2004 PED Approved Company.

TECHNICAL SPECIFICATION FOR 22 KV CURRENT TRANSFORMERS

JIS G3465 Seamless Steel Tubes for Drilling

TABLE OF CONTENTS. 1.0 Scope. 2.0 References. 3.0 Definitions. 4.0 Submission and Design Requirements. 5.0 Materials 5.1 General 5.

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

FOR READY MIXED PAINT, ALUMINIUM, BRUSHING, PRIMING, WATER RESISTANT, FOR WOODWORK

2.14 Main Cable Type HO7RN-F4G10-15 Metres each Chiller Tank Capacity- 75 Litres Compressor- 3.5 Tons Refrigeration type

GOST TUBING AND COUPLINGS

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

TECHNICAL SPECIFICATION

ISO INTERNATIONAL STANDARD. Fasteners Hot dip galvanized coatings. Éléments de fixation Revêtements de galvanisation à chaud

Securifor Polyester Coated Welded Mesh Panels

MATERIAL AND EQUIPMENT STANDARD FOR METRIC TYPE FASTENERS (SCREWS, BOLTS, STUDS, NUTS AND WASHERS) ORIGINAL EDITION DEC. 1997

Volume-II CENTER OF INNOVATIVE & APPLIED BIOPROCESSING DEPARTMENT OF BIOTECHNOLOGY (Govt. of India) Knowledge City, Sector 81, Mohali

Standard Specification for High-Strength Bolts for Structural Steel Joints [Metric] 1

Suggested Specification for Preparing Hot-Dip Galvanized Steel Surfaces for Painting Revised February 2002

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB/T Translated English of Chinese Standard: GB

Guideline for initial sample deliveries including initial sample test report to. Pankl Systems Austria GmbH. Systems

Standard Specification for Copper-Clad Steel Wire for Electronic Application 1

XLPE CABLE (33KV) September Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED

1. General Information Background Information Validity Basic Requirements Drawings and their Information...

Collins Engineers Palmetto Islands County Park Boardwalk Repairs 03/28/2014 SECTION ROUGH CARPENTRY

Content. Hot-dip galvanized narrow strip. Areas of application. Product information

1.0 mh, 3150 A LINE TRAP

ASSEMBLY TOOLS FOR SCREWS & NUTS. Part 1: Insulated hand operated socket drive wrenches and screw drivers

TABLE OF CONTENTS INTRODUCTION REBAR INSTALLATION SERVICES SPACERS MESH WIRE FENCING CONSTRUCTION PLASTICS HOLD DOWN BOLTS

TECHNICAL BID. T 4262 (E-Tender I.D. No. ) Subject: Supply of HT & SS fasteners, circlip & cotter pins for BMD-6 Ukai GSECL TPS. EMD D. D. No.

SECTION TRACER WIRE FOR NONMETALLIC PIPE

PUSH PINS, GEM CLIPS, STAPLE PINS & SAFETY PINS

City of Regina Standard Construction Specification SECTION 2660 CHAIN LINK FENCE

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT

GUIDELINE SPECIFICATIONS

SUBMITTAL SHEET. Project Submittals by

Our Ref: SRO/BM/C Date:

SECTION BULLET- RESISTANT DOORS

Quotation Swastik Rs Advance Rs

To be completed by the Bidder. Sl.No. Parameters CPRI Specification / Requirements Qty

DEPARTMENT OF ARCHITECTURE

NORMATIVE REFERENCES

TECHNICAL SPECIFICATION OF 11 KV AND 22 KV THREE PHASE FOUR WIRE, THREE

AS/NZS 1214:2016 Hot-dip galvanized coatings on threaded fasteners (ISO metric coarse thread series) AS/NZS 1214:2016

(TECHNICAL SPECIFICATIONS & GTP FORMATS) 11KV METERING UNITS

SECTION-IV TECHNICAL SPECIFICATIONS FOR TRANSFORMER REPAIRING MATERIALS

Engineering Test Report

Standard Specification for Carbon and Alloy Steel Nuts [Metric] 1

Oil tempered SiCrV-alloyed high tensile valve spring wire Only manudactured in China

SECTION CARPENTRY

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

NORMATIVE REFERENCES

SECTION-IV TECHNICAL SPECIFICATIONS FOR TRANSFORMER REPAIRING MATERIALS

Maharashtra State Electricity Distribution Co. Ltd.

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

ISO INTERNATIONAL STANDARD. Fasteners Hot dip galvanized coatings. Éléments de fixation Revêtements de galvanisation à chaud

Plant Client Contract Code Document ID Contract No. TECHNICAL SPECIFICATIONS DC SHUNT Rev 00 Page 1 of 2

Single-Phase Mini Pad-Mounted Transformer Specification: Energy+ MPDL

TECHNICAL SPECIFICATION FOR STEEL DRY CARGO CONTAINER 6'x1960mmx1920mm TYPE

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB/T Translated English of Chinese Standard: GB/T

Transcription:

1. SCOPE: TECHNICAL SPECIFICATION FOR G. I. WIRE (4MM) This Specification provides for manufacture, testing before dispatch at manufacturer's work and supply and delivery of 4mm solid heavily coated Galvanized solid steel wire to any of our Regional Stores in Gujarat State as intimated by the Company time to time. 2. STANDARD: The G. I. wire shall comply with the following Indian standards (subject in all cases to latest revision/amendments currently in force) Specification for Mild Steel Wire a) IS: 280/1978 (IIIrd revision). for general engineering purpose. "Specification for Hot Dipped b) IS: 4826/1979 (Ist revision). Galvanized coating on round steel wires." 'General requirements for the c) IS: 1867/1967 (Ist revision). supply to metallurgical materials.' Specification for Mild Steel Wire d) IS : 7887/1992 Rods for general engineering purpose. 'Method for tensile testing of steel e) IS : 1521/1972 (Ist revision) wires. f) IS : 1755/1983 'Method for wrapping test of wire'. 'Methods for testing uniformity of g) IS : 2633/1986 (Ist revision) coating on zinc coated articles'. 'Methods of determination of h) IS : 6745/1972 weight of zinc coating on zinc coated iron and steel articles'. i) IS : 209/1992 (IVth revision) 'Specification for zinc.' j) IS : 2629/1985 3. MATERIAL: 'Recommended practice for hot dip galvanizing of steel and iron'. General requirement relating to the supply of Mild Steel Wire shall be as per IS: 1387/1967. The wire shall be drawn from the Wire rods confirming to IS: 7887/1992. The wire shall be sound-free from splits; surface flares rough, jagged and imperfect edges and other harmful surface defect. 4. SIZES: 4.00 mm dia. 5. QUALITY: Both the sizes of G. I. wires shall be of soft drawn quality confirming to IS: 280/1978. DGVCL/SP/10038/G.I. Wire/Tech. Speci and GTP 4mm 1/5

6. TENSILE STRENGTH: The tensile strength of the G. I. wire when tested in accordance with IS : 1821/1972 shall be between 450.550 N/mm2. 7. ZINC COATING: The wire shall be galvanized in accordance with IS:2629/1986 and the zinc to be used for Hot dip galvanizing shall confirm to grade Zn-98, specified in IS:209/1992. The coating shall be uniform, smooth and free from visual defect. Such as flash and dress inclusion bare patches black spots, pimples, lumpiness, rust strains, bulky white deposit and bistros. The coating shall be "HEAVELY COATED QUALITY'. 8. TESTS: The following acceptance tests shall be carried out on each and every lot at manufacturers premises at the manufacturer's cost. The manufacturer must be fully equipped to carry out the tests at his premises in presence of Board's Inspectors. a) Visual examination. b) Checking of diameters of wires. c) Tensile Strength. As per relevant ISS specified d) Wrapping test. para -2 hereof. e) Mass of zinc coating. f) Uniformity of zinc coating. g) Adhesion of zinc coating. The manufacturer shall have to submit Test Certificates with every lot for the Chemical composition of the Steel rocs from which the wires are drawn. 9) SAMPLES: The sampling for Acceptance Test shall be carried out as per Appendix - 'A' of IS: 280/1978 (Third revision) 10. PACKING: The G. I. Wire shall be supplied in coils. The weight of the coil shall be 50 Kg. to 80 Kg. Each coil shall be wrapped in hession to avoid surface damage to the wire during transport and for protection against pollution. Each coil shall be supplied with a metallic tag on which the following particulars shall be printed itched with waterproof ink/itched. 1) Name of Manufacturer. 2) Size of Wire. 3) Weight of Coil (approx.) Kg. DGVCL/SP/10038/G.I. Wire/Tech. Speci and GTP 4mm 2/5

4) Coil Serial No. 5) A/T No. & Date,. 6) ISI Mark if any. 7) Property of DGVCL. 11. SEALING: The manufacturer shall keep coils ready with seal wire and lead seal so as to enable the Board's inspectors to seal the inspected material immediately. Wrapping of coils with hession shall be done after inspection but before dispatch. 12. GUARANTEED TECHNICAL PARTICULARS: The tenderers shall submit the Guaranteed Technical Particulars as per the proforma SECTION-II attached herewith only. The offers without technical particulars shall be ignored. 13. DEVIATION FROM SPECIFICATION: No deviation in the above specification shall be allowed. Name of Manufacturer: & Address. DGVCL/SP/10038/G.I. Wire/Tech. Speci and GTP 4mm 3/5

GUARANTEED TECHNICAL PARTICULARS. Technical information and guaranteed Technical Particulars for supply of G. I. Wire size 3.15mm dia (10SWG) and 4.00 mm dia (8SWG). PART A Bidder has to confirm following important requirement: Sr.No Particulars. Confirmation 1) The G I. Wire of 3.15mm dia x 4.00mm dia with tolerance of +or- 2.5 % in dia as per IS:280/1978 with latest amendment/revision if any. 2) The G. I. Wire shall drawn from soft wire having tensile strength 450-550 N/mm2 3) Breaking Load shall be as under : for G. I. Wire 3.15mm dia x 339.3 to 459.2 for G. I. Wire 4.00 mm dia 544 to 740.54 4) Zinc coating shall be as under i) Heavy coating IS : 4826/78 ii) How dip galvanizing, weight of zinc coating when tested IS : 4826/79 iii) The quality of zinc shall be as per IS : 209/1992 iv) No. of dip guaranteed. 3 Nos. of 1 minute dips & 1 No. 1/2 minute dip as per IS:2633/1986 5) Weight of coils shall be from 50 Kg. to 80 Kg. 6) Packing condition as per clause No. 10 of Tender specification. PART B (ENCLOSERS) Bidder has to enclose following documents and has to conform for the same: Sr.No Particulars. Confirmation 1) List of Plant and Machinery. 2) List of Testing Equipments. 3) List of Orders pending / executed atleast for past two years for the item offered: (A) With GUVNL. (B) With the purchase other then GUVNL.. DGVCL/SP/10038/G.I. Wire/Tech. Speci and GTP 4mm 4/5

PART C Bidder has to mention below deviation if any, quoting relevant clause of specification. SIGNATURE & SEAL OF TENDERER. DGVCL/SP/10038/G.I. Wire/Tech. Speci and GTP 4mm 5/5