TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

Similar documents
CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide

SJ100 Series Inverter Quick Reference Guide. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

The GS1 Digital Keypad LED Display Function Keys Displaying the Status of the GS1 AC Drive Programming the GS1 AC Drive...

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

TOSVERT TM VF-nC3 Parameter List

NX series Constant and variable torque Variable Speed Drives for induction motors

CHAPTER 8 PARAMETER SUMMARY

Fan and Pump AC Inverter

ADTECH Solar inverter

A510 INVERTER. 230VClas3~ kW 1-3HP HP kW 1-425HP. 460VClas3~ 575/690VClas3~ 1-270HP INSTRUCTIONMANUAL

AV-300i Specifications. Saftronics Inc. VG10 Product Specifications VG10. Dynamic Vector Drive

GS1 Parameter Summary Detailed Parameter Listings...4 9

HPVFP High Performance Full Function Vector Frequency Inverter

6.9 Jump frequency - Avoiding frequency resonance

VSD Series II Variable Speed Micro Drives (VSM II) FS1 FS5

vacon nx all in one application manual ac drives Phone: Fax: Web: -

VFS11 Parameter List for up to CPU version 105

Operating Instructions

NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives

3. Be aware of the ambient temperature. Use the unit within the specified ambient temperature only.

General Specifications FECA-TE /2010. Phone: Fax: Web:

Before you operate the inverter, the parameters that you must first program are the basic parameters.

ADJUSTABLE SPEED DRIVES. AS1 Drive

VFS9 Parameter List for Version110 or later

AF-300 G11 Specifications. GE Industrial Systems. Product Specifications AF-300 G11

NX Series Inverters. HVAC Pocket Programming Guide

FREQUENCY INVERTER VFR-013 QUICK START GUIDE

VSC. Instruction Manual - English

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB

The Drive & Control Company. Frequency Converter. VFC 3610 / VFC 5610 Series. Quick Start Guide R Edition 10

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

ROLL TO ROLL FUNCTION MANUAL FR-A (0.4K)-04750(90K)-R2R FR-A (0.4K)-06830(280K)-R2R FR-A (315K)-12120(500K)-R2R

CHAPTER 3 WIRING DANGER

Version number A=standard P=Cold Plate (Frame A only) T=Brake chopper (Frame A only) Input voltage 11=115VAC 21=230VAC 1φ 23=230VAC 3φ 43=400VAC

safety Doc: DPD00714C, Released: vacon 1 ONLY A COMPETENT ELECTRICIAN IS ALLOWED TO CARRY OUT THE ELECTRICAL INSTALLATION! 1.

N3 INVERTER SERIES. Operating Manual. 230V 1Ø 0.5-3HP kW. 230V 3Ø HP kW. 460V 3Ø 1-75HP kW. Revision: 2.03.

vacon 100 flow ac drives application manual

TABLE OF CONTENTS CHAPTER 1 SAFETY PRECAUTIONS... 1 CHAPTER 2 MODEL DESCRIPTION... 6 CHAPTER 3 ENVIRONMENT AND INSTALLATION... 9

Hitachi P1 Closed Loop Hoist Basic Instruc on Manual

Multi-function, Compact Inverters. 3G3MV Series

user's manual nx frequency converters beam pump application asfiff13

CHAPTER 8 SUMMARY OF PARAMETER SETTINGS

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

Comp-AC. User s Manual for type ACS 140 frequency converters from 0.12 to 2.2 kw

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB. For Immediate Delivery call KMParts.com at (866)

QUick StARt guide. Customised to your machine Model: 3G3RX 200 V Class Three-Phase Input 0.4 to 55 kw 400 V Class Three-Phase Input 0.

SV9000 SVReady USER MANUAL CONTENTS OPEN SV9000 USER MANUAL. SV9000 Page 0-1

NICE900 -Door Drive Setup Manual for Asynchronous / Synchronous Motor with Encoder Feedback (Document Release Dt ) Sr. No

ADJUSTABLE SPEED DRIVES FS1

G+ Mini Transition Guide. Product Transition Guide P3 Series 2 to G+ Mini

MA7200 PLUS INVERTER SERIES PID Quick Start Manual For Fan and Pump Applications

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

Preface IMPORTANT NOTES PV series Solar Pumping Inverter

Compact & Powerful Inverter STARVERT ig5a 0.4~1.5kW 1phase 200~230Volts 0.4~22kW 3Phase 200~230Volts 0.4~22kW 3Phase 380~480Volts

FE0 9

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

AV-300i Specifications. GE Industrial Systems. Product Specifications. A New Concept in Automation. AV-300i

vacon nxp arfiff30 user manual generator application ac drives

MD310 Quick Start Manual. General-Purpose AC Drive

User Guide. Optidrive Plus 3 GV Compact. OEM AC Variable Speed Drive kW (1 2HP) Installation and Operating Instructions

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

Table of Contents Preface Chapter 1 Safety Precautions Chapter 2 Model Description Chapter 3 Environment and Installation...

SSI3300 operating manual CONTENTS

Altivar 68 Telemecanique

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

vacon 10 ac drives quick guide

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS

Contents. Safety Information and Precautions Product Information Operation Panel (Keypad & Display) Quick Setup...

CONTENTS CONTENTS...1 SAFETY PRECAUTIONS INTRODUCTION...4

S11 Adjustable Speed Drive Engineering Specification

THYFREC-VT210S 400V System 37 to 315kW (C/T) 400V System 45 to 370kW (V/T) QUICK START GUIDE

User Guide. Optidrive Plus 3 GV Compact & Optidrive PCE. Compact AC Variable Speed Drive & Motor Mount Enclosure

vacon nx ac drives all in one application manual

VF-nC1 Adjustable Speed Drive Engineering Specification

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

Rexroth Frequency Converter Fe 0.75 kw to 7.5 kw / 400 VAC

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS

FUJI Inverter. Standard Specifications

Goodrive inverter for air compressor. Preface

GB QUICK GUIDE FOR THE CONFIGURATION OF VARIABLE SPEED DRIVES

4.2.3 Main Circuit Cable Size and Tightening Torque Control Circuit Control Circuit Terminals

VLT MICRO Series Adjustable Frequency Drive Instruction Manual

USER MANUAL Version: 1.1

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

Document number: Document version: r2 Date of release: Copyright Emotron AB 1998 Emotron AB reserves the right to alter product

KBDA SERIES STANDARD FEATURES DESCRIPTION PERFORMANCE FEATURES PROTECTION FEATURES

ADJUSTABLE SPEED DRIVES VF-S11 Sords Electric

[ 4 ] Using pulse train input (F01 = 12)

VS-616G5 Series (Revision F) Programming Manual. Constant Torque Inverter with Adaptive Vector Control (AVC )

Dual-inverter Wire Drawing Machine CHV130 series Frequency inverter Operation manual

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

OPC-E1-PG3 Specifications

ig5a Compact AC Drive 0.4~1.5kW(0.5~2HP) 1-phase 200~230Volts 0.4~22kW(0.5~30HP) 3-Phase 200~230Volts 0.4~22kW(0.5~30HP) 3-Phase 380~480Volts

THYFREC-VT110S 200V 1PH System 0.4 to 2.2kW 400V 3PH System 0.75 to 2.2kW QUICK START GUIDE

Transcription:

Quick Start Guide TECO F510 Inverter This guide is to assist you in installing and running the inverter and verify that it is functioning correctly for it s main and basic features. For detailed information and if there are any doubts please refer to the instruction manual. Step 1 Supply & Motor connection 1) Ensure that the Inverter & the motor have the correct KW power and voltage ratings. Motor full load amps must not exceed the Inverter rating. 2) Ensure that the supply & Motor cables are connected correctly prior to power up. 3) Connect supply cable to terminals R/L1, S/L2, T/L3 4) Connect motor cable to terminals U/T1, V/T2, W/T3 (Swap two leads if motor runs in reverse direction). 5) Connect supply Earth and the motor Earth to the drive Earth terminal. Note:- I ) For detailed installation and wiring refer to the Instruction manual. Page 1 of 11 06/10/17

Step 2 Apply power to the drive Apply power to the drive, the display will briefly show the supply voltage 440V followed by 005.00 flashing. This is the default (factory set) frequency. If the unit has been used previously then it will show the last frequency programmed. Step 3 Test run from keypad Press RUN KEY to run. The frequency will ramp up to 5.0 Hz or the user pre-set frequency according to the default acceleration ramp time. Press STOP key to stop. The frequency will ramp down to zero according to the default decel ramp time. Step 4 To alter frequency from keypad. (Default setting). Use the Arrow keys and </RESET key to alter the digits to the required frequency. To store the set frequency use READ/ENTER Key. eg. 50.0 HZ then use RUN and STOP keys to start/ stop. Page 2 of 11 06/10/17

Remote speed reference and Remote run Step 1 Remote mode wiring. Speed reference. 1) Ensure that you have carried out installation & wiring requirements as per step1 quick start guide on previous page before you proceed. Two analogue inputs are available. AI1 & AI2 Ensure 00-07 = 0 ( Default= Main frequency source). 2) Select AI1 or AI2 as required. AI1 Voltage only Input. Speed command 0 to +10V AI2 Multi-function analog input terminal. Use SW2 to switch voltage or current input 0 to +10V 4 to 20 ma Settings for AI1: Set 00-05=1 Settings for AI2 : Set 00-05 = 7 ( AI2 Aux frequency) Set 04-05 = 0 ( Default). Aux frequency. Set 04-00 = 0 for ( 0-10v or 0-20mA) Set 04-00 = 1 for ( 2-10v or 4-20mA) 3) Connecting Remote Potentiometer: Terminal +10V Supply for use with the potentiometer. Terminal GND 0Vdc Terminal AI1 or AI2 Potentiometer wiper connection. 4) Connecting Remote 0-10V or 4-20mAc signal Use terminals AI1 or AI2 as required. Connect the 0 V of the analogue input signal to Terminal GND. Page 3 of 11 06/10/17

Step 2 Remote mode Run 1) Remote Run signal can be either a PNP or NPN input type. Set PNP or NPN selection as required by SW3. Note : PNP (positive voltage switching) selection is recommended for use in EU. 2) Connect remote start switch if required according to diagram in the instruction manual. Terminal 24V & S1 (Forward run) Terminal 24V & S2 (Reverse run) 24V is the common terminal for PNP type inputs. 24VG (0Vdc) terminal is common for the NPN type inputs. Step 3 Check/ verify and alter parameters Check / verify and alter parameters for remote start & remote frequency as necessary before you proceed. Parameters 00-02 & 00-05 See quick start parameter list & How to alter parameters. Step 4 RUN using remote speed reference. (Potentiometer, 0-10Vdc or 4-20mA) 1) To run. Activate the remote run switch connected to terminals S1 (FWD) or S2 (REV) as required. Parameter 00-02 =1 The frequency will ramp up to the frequency set from keypad or analogue inputs 1 & 2.and according to the set acceleration ramp time. How to alter parameters 2) To Stop. De-activate the remote run switch. The frequency will ramp down to zero and according to decel ramp time. Page 4 of 11 06/10/17

How to alter Parameters from keypad 1) To alter parameters:- Press the DSP/FUN key, until the first parameter 00-00 is displayed. 2) Then use the arrow keys </RESET to select the parameter required then press READ/ENTER key to read the preset value. 3) Use and </RESET keys to alter the setting of the parameters as per basic quick start parameter list. Note:- For full parameter list refer to the instruction manual. 4) To save each parameter change, press READ/ENTER key then the word END will be displayed. 5) Use </RESET key to select the next parameter to alter and follow steps 2 to 4 until all changes are complete. 6) Pressing the DSP/FUN key repeatedly will alternate the display between the preset frequency (flashing display) and the last parameter accessed or other selectable displays 0 to 7 when selected by parameter 12-00 according to the table below. 0 :Disable Display 1 :Output Current 2 :Output Voltage 3 :DC Bus Voltage 4 :Temperature 5 :PID Feedback 6 :AI1 Value 7 :AI2 Value Page 5 of 11 06/10/17

Type Name Functions Main digital displays Frequency, parameter, voltage, current, temperature and Fault message. FAULT: When the inverter has a warning or fault message, the indicator lights up. FWD: When the inverter is in forward run mode, the indicator lights up. RUN mode: Continuously ON. Stop mode: Flashes ON/OFF. Display REV: When the inverter is in revere Run mode, the indicator LED status display lights up. RUN mode: Continuously ON. Stop mode: Flashes ON/OFF SEQ: When Run command source is set to external control, the indicator lights up. REF: When Frequency command source is set to external control, the indicator lights up. Keys RUN RUN: Run command at the set frequency. STOP STOP: Stop command. Decelerate or Coast to stop. Page 6 of 11 06/10/17

(8 keys) Increments parameter number and preset values. LOC/REM DSP/FUN </RESET READ/ENTER Decrements parameter number and preset values. Alternates frequency and run command source between LOCAL and REMOTE: REMOTE mode: inverter is controlled per parameter settings through control circuit terminals or communication. LOCAL mode: Inverter is controlled through digital operator. By default REMOTE mode is effective at power on. Press LOC/REM key to switch between the modes while inverter is stopped. LOC/REM key can be disabled by parameter 23-41. Select between Frequency, Function (parameters) and Monitor displays according to the following sequence. Frequency screen Function selection Monitor parameters Frequency screen. < is left shift key. It s used for changing parameter or value. RESET key:use to reset Inverter resettable faults. Used to display the preset value of parameters and for saving the changed parameter values. Basic Quick Start Parameter List Parameter Default Range Note 00-00 0 0, 2, 5 Control Mode:- 0: V/F 2: SLV (Sensorless Vector) 5: PM SLV (Sensorless Vector for Permanent Magnet Motor) 00-02 0 0-4 Run mode:- 0: Keypad 1: External control terminal 2: Communication 3: PLC 4: RTC 00-05 0 0-7 Frequency source:- 0: Keypad 1: Remote control (Analogue Input AI1) 2: External up/down frequency control 3: Communication 4: Reserved 5: PID output 6: RTC 7: Auxiliary Frequency (AI2) 00-01 0 0-1 Run direction:- 0: Forward 1: Reverse 00-12 100.0% 0.1-109% Max frequency limit. (default 100%) 00-13 0.0 % 0.0-109% Min frequency limit. (default 0.0%) Page 7 of 11 06/10/17

07-09 0 0-3 Stop method: 0: Deceleration to stop 1: Coast to stop 2: DC injection braking 3: Run signal inhibit (timer) during Coast to stop 02-01 **A 10%~200% of rated current (V/f) 25%~200% of rated current (SLV) Motor rated current (for Motor overload protection) 13-08 0 0-10 Factory Reset: Inverter Supply voltage. 2: 2 wire initialization(220/440v,60hz) 3: 3 wire initialization(220/440v,60hz) 4: 2 wire initialization(230/415v,50hz) 5: 3 wire initialization(230/415v,50hz) 6: 2 wire initialization(200/380v,50hz) 7: 2 wire initialization(200/380v,50hz) 8: PLC initialization 9: 2 wire initialization(230/460v,60hz) 10: 3 wire initialization(230/460v,60hz) Note:- For Full Parameter List see the Instruction manual Control Modes & Auto Tune F510 provides three control modes. Select the relevant control mode for the application. Default control mode is V/f. V/f can be used for most applications specifically multi-motor or applications where auto tune is not successful or when a customized v/f pattern may be required. Several V/f patterns are available selectable by parameter 01-00. Select the appropriate one based on the application load type and the motor base frequency of 50 or 60 Hz. For selections of the V/f patterns, Refer to the instruction manual. Sensorless Vector mode SLV is used for obtaining best performance from a motor. V/f Mode Parameters Parameter Default Range Note 01-00 F 0-FF F: General Purpose. 60Hz system 0: General Purpose. 50Hz system For full list of preset patterns set by 01-00, refer to the manual. FF: Customized V/f. Set parameters 01-02 to 01-13 Page 8 of 11 06/10/17

For Motor parameters in V/f mode, set the name plate data in parameter Group 2. SLV Mode set parameters in parameter Group 17 Motor parameters are automatically set when performing an auto-tune (17-10 = 1). In most case no adjustment is required after performing an auto-tune except when using the inverter in special applications (e.g. machine tool, positioning, etc ). Enable auto tune function by parameter 17-10. Press RUN button (after display showing Atrdy ) Six auto tune modes are available. Rotational, Static, Stator Resistance, and loop turning. Use Rotational where possible. Motor rotates the process takes about 50 secs Use Static when rotation of load is not possible. It takes about 35 secs. Use Line to Line Resistance for long cable (above 50 meters in V/f mode) Use Loop turning to enhance vector control performance. Rotational Auto-tuning.Combination (Item: 4+2+0). V 1.41 Static Auto-tuning. Combination (Item: 4+2+1). V 1.41 Group 17 Automatic Tuning Function Group Code Parameter Name Range Default Unit 0: rotational autotune 1: static autotune 2: stator resistance measurement 0-17-00 3: Reserved Mode selection of automatic 4: loop turning tuning 5: Rotational Auto-tuning Combination (Item: 4+2+0). V 1.41 6: Static Auto-tuning Combination (Item: 4+2+1). V 1.41. 17-01 Motor rated output power 0.00~600.00 - KW 17-02 Motor rated current 0.1~999.9 - A 17-03 Motor rated voltage 200V: 0.0~255.0 220 400V:0.0~510.0 440 V 17-04 Motor rated frequency 10.0~400.0 60.0 Hz 17-05 Motor rated speed 0~24000 - rpm 17-06 Pole number of motor 2-16 (even number) 4 Pole 17-08 Motor no-load voltage 200V: 50~240 400V:100~480 - V 17-09 Motor excitation current 0.01~600.00 - A 17-10 Automatic tuning start 0: Disabled 1: Enabled 0-17-11 Auto tune Error History 0: No error 1: Motor data error 2: Stator resistance tuning error 3: Leakage induction tuning error 4: Rotor resistance tuning error 5: Mutual induction tuning error 6: Reserved 7: DT Error 0 - Page 9 of 11 06/10/17

Group 17 Automatic Tuning Function Group Code Parameter Name Range Default Unit 17-14 Rotational Tuning Mode Selection. V 1.41 8: Motor acceleration error 9: Warning 0: VF Mode 1: Vector Mode Note:- No-load motor voltage 17-08 & (02-19) Parameter determines the rated flux during motor s rated rotation in SLV control mode. Set the value of this parameter to the same value as parameter 17-08. A value of 10~50V below the rated input voltage level (parameter 17-03) ensures that the motor is capable of providing adequate torque performance when operating at nominal speed (or higher speed). Setting the value too small can result in a reduction in no-load current, weakened motor flux and an increase in motor current while the motor is loaded, causing a reduction in torque performance. For high KW rating (55KW and above), set this closer to the supply voltage. Motor excitation current 17-09 & (02-09) This parameter is automatically set during auto-tune. No adjustment required. For static tuning & Resistance tuning this parameter needs to be adjusted Set to 1/3 of the motor rated current parameter (17-02). Wiring Diagram Page 10 of 11 06/10/17

Main circuit power NFB MC Fast acting fuse R/L1 S/L2 T/L3 Braking resistor B1/P B2 *1 U/T1 V/T2 W/T3 IM Multi-function input Forward rotation/stop Reverse rotation/stop UP command DOWN command Multi-step speed command 1 Fault reset S1 S2 S3 S4 S5 S6 24V SW6 V AO2 SW3 *2 I Source(PNP) 24VG Common terminal of digital signal (NPN) E SW1 V AO1 Analog output 1 I Sink(NPN), Default setting Power terminal of digital signal (PNP) Connection terminal of shielding wire +10V Power for analog input, +10V, 20mA Analog output 2 CN3 E AO1 AO2 GND E R1A R1B R1C R2A R2C Grounding resistance should lower than 100Ω Analog signal output 1, 2 (DC 0~10V)/4-20mA Option Card (JN5-IO-8DO) Multi-function relay output 250VAC, under to 1A 30VDC, under to 1A External analog input 0~10V 0~10V/0~20mA or 4~20mA 0V Pulse input P P P AI1 Multi-function analog input SW2*3 (0~10V, 20KΩ) V AI2 Multi-function analog input (0~10V/0~20mA or 4~20mA, 250Ω) I Default setting GND Common terminal of analog signal MT PTC Motor temperature detector input PI Pulse command input 32K Hz. Max. R3A R3C PO GND P Energy meter pulse output Screened Cable Terminal symbol Screened Cable, P Twisted Pair Indicates main circuit Indicates control circuit F1 Run Permissive input F2 *4 SW5 ON OFF CN6 (RJ45) 1 S(+) 2 S(-) RS485 1: Data+ 2: Data- 3: Data+ 4: Reserved 5: Reserved 6: Data- 7: 5V 8: GND Remark: *1: Models IP20 200V 5~30HP, 400V 5~40HP and IP55 400V 5~25HP have a built-in braking transistor so that the braking resistor can be connected between terminal B1 and B2. *2: The multi-function digital input terminals S1~S6 can be set to Source (PNP) or Sink (NPN) mode via SW3. *3: The multi-function analog input 2 (AI2) can be set to the voltage command input (0~10v) or the current command input (4~20mA) via SW2. *4: Run permissive input F1 & F2 is a normally closed input. This input should be closed to enable the inverter output. To activate this input, open the link between F1 and F2. Page 11 of 11 06/10/17