DATA SHEET. CIO multi-inputs. CAN bus-based I/O module

Similar documents
RMV-122D, RMV-132D ANSI

DATA SHEET Differential current relays, RMC-131D ANSI code 87

TCM-2 Thyristor Control Module DATA SHEET

DATA SHEET Reverse power relays, RMP-121D ANSI code 32

DATA SHEET. Paralleling relays, HAS-111DG ANSI code 25

Function. Adjustment. Extra functions included. Modes. Housing

DEIF A/S. User s manual. Read synchroscope type RSQ-3. Precision LED synchronoscope. High immunity to harmonic distortion F (UK)

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions

DATA SHEET AC current single function transducer TAC-311DG/TAC-321DG

DATA SHEET. Voltmeters and Ammeters,

DATA SHEET Selectable AC transducer TAS-311DG

DEIF A/S. Insulation monitor. Type SIM-Q

Protection relays and controllers. Types TRANSAL DC-2TF, ACV-3TF, ACI-3TF, PFC-2TF TRANSAL DC-2TB, AVC- 3TB, ACI-3TB, PFC-2TB

DEIF A/S. Insulation monitor. Type SIM-Q/SIM-Q LF

Electronic timer CT-TGD.22

Electronic timer CT-SDD.22


"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

Type Nominal voltage (V) Code HSV V

FC Series Signal Conditioners

Custom "Compact" range with display CD20 Custom Part number

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Automatic synchronising relay

27/04/2015

02/11/2015

Installation and start up instructions. Paralleling relay type HAS-111DG uni-line G (UK) Synchronisation of generator to busbar

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

em4 local - Robust Specific characteristics Part number

02/11/2015

DATA SHEET. Switchboard instruments,

Type CP-S, CP-C & CP-A Switch mode

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Assembly. Front view. Parametrization interface. Power Bus

Zelio Control Measurement Relays

02/11/2015

CP-E range Benefits and advantages

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

02/11/2015

02/11/2015

Electronic timer CT-SDS.22

Programmable AC Current Transducer MT418

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

200 Watt Passive Shunt Module

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Power supply CP-E 24/0.75

INSTRUCTION SHEET. Eaton Logic Controller ELCM TC Temperature Modules. [Applicable Temperature modules] ELCM-TC04ANNN MTN1

Power supply CP-D 24/4.2 Primary switch mode power supply

AI 043 S-DIAS Analog Input Module

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

Installation and start up instructions. Synchroniser type FAS-115DG uni-line H (UK) Synchronisation of generator to busbar

Power supply CP-D 24/1.3

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

Installation and start up instructions. Synchroniser type FAS-113DG uni-line F (UK) Synchronisation of generator to busbar

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Programmable AC Voltage Transducer MT416

Power supply CP-D 12/2.1

CP-T range Product group picture

FOUNDATION Fieldbus Junction Box

ISOMETER IRDH575. Approvals

Control module CP-A CM

Temperature Transmitters - DIN Rail Mounted

USB-2404-UI Specifications

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-MFS.21

Single phase meter with direct connection and pulse or Modbus RS485 output

Installation requirements

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Temperature Transmitters - Head Mounted

20 General technical data XI/ON

CP-T range Benefits and advantages

EY-EM 527: Remote I/O module, ecolink527

Primary switch mode power supplies Product group picture

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Transducers for AC measurement. Types TAP, TAQ, TMF, TAA, TAV, TAC. Measurement of: watt, var, frequency, phase angle, voltage, current

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

Safety switches with slotted hole lever

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

New Products Catalogue 2009 Safety Relays ESR5

Power supply CP-T 48/20.0 Primary switch mode power supply

Subject to changes 11/2003 Page 1/7

SEN TRONIC AG. Millenium 3 Essential. Essential range: powerful but cost effective. Part numbers. Accessories

Power supply CP-E 24/2.5

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 24/20.0 Primary switch mode power supply

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Liquid level monitoring relay CM-ENS.2x

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

MULTIFUNCTION GRAPHICAL UNIT MGU 800

Power supply CP-E 24/2.5

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Transcription:

DATA SHEET CAN bus-based I/O module 8 multi-functional inputs Selectable as: o Digital input, 0(4) to 20 ma, 0 to 10 V, RMI, Pt100, Pt1000, Thermocouple type E, J, K, N, R, S or T Wire break detection CAN bus interface LEDs to indicate status and input state 12/24 V DC supply Document no.: 4921240554A SW version: 1.10.0

Application The CIO series includes external I/O modules for some DEIF controllers in case the demand for inputs and outputs exceeds the capacity of the controller. Host controllers The CIO modules need a host controller to send and receive their information. Below are the controllers that support CIO modules. Type from SW version CIO 116, Quantity CIO 208, Quantity CIO 308, Quantity AGC 200 v. 4.59.x 3 3 3 AGC 4 v. 4.59.x 3 3 3 Common functions Status output The status output relay is active when the CIO module works properly and communicates with the host controller. The microprocessor is supervised by a watchdog circuit. Status LED The status LED indicates the state of the module and state of the status relay. Note: The status output can be re-configured as an output. CAN LED The CAN LED indicates the status of the CAN bus communication to the host controller. CAN bus end resistor The CIO module has a built-in 120 Ω end-termination for the CAN bus line which can be activated via the switch (S1). DEIF A/S Page 2 of 10

Input LEDs All 8 inputs have a green LED next to each input terminal to indicate the state of the input. Input type LED Description Digital input On Input is active Off Input is inactive 0(4) to 20 ma On Within input range 4 to 20 ma Off Outside input range 4 to 20 ma (LED is flashing when in protection mode: >30 ma) 0 to 10 V On Within input range 0.2 to 10 V Off Outside input range 0.2 to 10 V RMI On Within input range 10 to 2500 Ω Off Outside input range 10 to 2500 Ω Pt100 sensor On Within selected input range (low range -50 to 250 C or high range: -200 to 850 C) Off Outside selected input range (low range -50 to 250 C or high range: -200 to 850 C) Pt1000 sensor On Within selected input range (low range -50 to 250 C or high range: -200 to 850 C) Off Outside selected input range (low range -50 to 250 C or high range: -200 to 850 C) Thermocouple On Within input range of selected type of thermocouple Off Outside input range of selected type of thermocouple ID selector The ID selector is used to give CIO modules of the same type different IDs. All three types of CIO modules can use IDs from 1 to 15, and different module types may use the same ID. USB connection The USB port can only be used to update the firmware of the module. Configuration is not possible via this port. Note: To update the firmware, the CIO module ID switch must be set to ID 0. CAN bus The CAN bus interface is intended for DEIF host controllers only. It will be possible to have additional CAN bus communication devices (J1939 or CANopen) on the same CAN bus line but not acting as a host for the CIO module. It is described in the manual of the host controller if it supports this feature. DEIF A/S Page 3 of 10

CIO 308 hardware Terminal Name Description Comment 1 + +12/24 V DC 2-0 V DC Power supply 3 Common Status 4 Normally open Status output (configurable) 5 H CAN-High 6 Com CAN-Common CAN bus interface 7 L CAN-Low 8 9 I8 10 Input C 11 12 I11 13 Input C 14 15 I14 16 Input C 17 18 I17 19 Input C 20 21 I20 22 Input C 23 24 I23 25 Input C 26 27 I26 28 Input C 29 30 I29 31 Input C Multi-input 8 Multi-input 11 Multi-input 14 Multi-input 17 Multi-input 20 Multi-input 23 Multi-input 26 Multi-input 29 Multi-input group 1 Multi-input group 2 DEIF A/S Page 4 of 10

Available variants Type Variant no. Description Item no. Note CIO 308 01 CIO 308 8 multi-inputs 2912890260 8 multi-inputs DEIF A/S Page 5 of 10

Technical specifications Operating temp.: -40 to 70 C (-40 to 158 F) to IEC 60068-2-1/2 Max. surrounding air temperature 70 C (158 F) Storage temp.: -40 to +70 C (-40 to +158 F) Climate: 97 % RH to IEC 60068-2-30 Operating altitude: Max. 4000 meters above sea-level Aux. supply: Nominal 12/24 V DC (operational 9.0 to 36 V DC) 0 V DC for maximum 30 ms when coming from at least 12 V DC (cranking dropout) 0 V DC for maximum 100 ms when coming from at least 24 V DC (cranking dropout) The aux. supply input is to be protected by a 2 A slow-blow fuse. If protection against load dump is required, use a 12 A slow-blow fuse. Consumption: Load dump: Status output: Multi-inputs: Digital input: Current: Voltage: Pt100/1000 (Low range): PT100/1000 (High range): RMI, 2 or 3 wire: RMI, 1 wire (system ground used as second wire): Thermocouple type, range and tolerance: 10 to 32.5 V DC Min. 1.4 W Max. 2 W ISO 16750-2 Test A (24 V DC system) SAE J1113-11 Pulse 5 A Power supply ports: Test 1 to 123 V at 1 Ω for 100 ms Test 2 to 174 V at 8 Ω for 350 ms Solid state output Maximum 30 V AC or DC Temperature from -40 to +40 ºC max. 1 A resistive load Temperature from +40 to +70 ºC max. 0.8 A resistive load Dry contact inputs, 3 V DC internal supply Wire-break detection with maximum resistance for ON detection: 100 Ω Range 0(4) to 20 ma Accuracy: ±10 ua + 0.25 % rdg 1) Range 0 to 10 V DC Accuracy: ±10mV + 0.25 % rdg 1) Range -50 to 250 C Accuracy: ±1 C + 0.25 % rdg Range -200 to +850 C Accuracy: Range 0-2500 Ω Accuracy: ±2 Ω + 0.25 % rdg Range 0-2500 Ω Accuracy: ±5 Ω + 0.25 % rdg 1) E: -200 to 1000 C J: -210 to 1200 C K: -200 to 1372 C N: -200 to 1300 C R: -50 to 1768 C S: -50 to 1768 C T: -200 to 400 C Note 1: rdg = actual reading Note 2: twisted pair and shielded cable is recommended to achieve specification and optimisation of immunity-noise. DEIF A/S Page 6 of 10

Internal sensor for cold junction compensation (CJC): Galvanic separation: Mounting: Connections: Terminals tightening torque: Accuracy: ±1 C in the operating temperature range: -40 C to 70 C Between supply and other IOs: 600 V 50 Hz for 1 minute. Between CANbus interface and other IOs: 600 V 50 Hz for 1 minute. Between status relay output and other IOs: 600 V 50 Hz for 1 minute. DIN rail mounting inside a cabinet or other enclosure Compatible DIN rails: - TS35/top hat 35 mm (this rail type is used in all product tests) According to EN 50022 - G-type rail According to EN 50035, BS 5825, DIN 46277-1 To be installed in accordance with the NEC (US) or the CEC (Canada) Minimum 0.2 mm2 (24 AWG) multi-stranded Maximum 2.5 mm2 (12 AWG) multi-stranded Firmware port: USB-B Use min. 90 C copper conductors only Minimum 0.5 Nm (4.4 lb-in) Maximum 0.6 Nm (5.3 lb-in) 0.5 Nm (4.4 lb-in) Approvals: CE UL/cUL Listed to UL508 and CSA C.22.2 No. 142-M1987 UL/cUL Recognized to UL6200 and CSA C.22.2 No. 14-13 (pending) Weight: 333 g (0.73 lbs) Safety: IEC/EN 60255-27, CAT III, 50 V, pollution degree 2 Protection: IP20 - IEC/EN 60529 NEMA type 1 Type complete device, Open Type 1 EMC/CE: EN 61000-6-1/2/3/4 IEC/EN 60255-26 IEC 60533 power distr. zone IACS UR E10 power distr. zone Vibration: Test performed with CIO module mounted on top hat 35 mm DIN rail 3 to 13.2 Hz: 2 mmpp 13.2 to 100 Hz: 0.7 g To IEC 60068-2-6 To IACS UR E10 10 to 58.1 Hz: 0.15 mmpp 58.1 to 150 Hz: 1 g To IEC 60255-21-1 Response (class 2) 10 to 150 Hz: 2 g To IEC 60255-21-1 Endurance (class 2) 3 to 8.15 Hz: 15 mmpp 8.15 to 35 Hz: 2 g To IEC 60255-21-3 Seismic (class 2) DEIF A/S Page 7 of 10

Shock: Test performed with CIO module mounted on top hat 35 mm DIN rail 10 g, 11 msec, half sine To IEC 60255-21-2 Response test (class 2) 30 g, 11 msec, half sine To IEC 60255-21-2 Withstand test (class 2) Bump: Material: 50 g, 11 msec, half sine To IEC 60068-2-27 Test performed with CIO module mounted on top hat 35 mm DIN rail 20 g, 16 msec, half sine To IEC 60255-21-2 (class 2) All plastic materials are self-extinguishing according to UL94 (V1) DEIF A/S Page 8 of 10

Unit dimensions in mm (inches) A Width [A]: 156 mm [+/- 0.5 mm] (6.14 in.) DEIF A/S Page 9 of 10

Order specifications Variants: Mandatory information Item no. Type Variant no. Example: Mandatory information Item no. Type Variant no. 2912890260-01 CIO 308 01 DEIF A/S, Frisenborgvej 33 DK-7800 Skive, Denmark Due to our continuous development we reserve the right to supply equipment which may vary from the described. Tel.: +45 9614 9614, Fax: +45 9614 9615 E-mail: deif@deif.com, URL: www.deif.com