Certificate of Compliance

Similar documents
Certificate of Compliance

Certificate of Compliance

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers

FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

CERTIFICATE OF COMPLIANCE

IP26 Series Current to Pneumatic Converter

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Certificate of Conformity

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Description. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461

DPharp Differential Pressure and Pressure Transmitters

KFS. Flap-type flow meter. Design and range of application

CERTIFICATE OF COMPLIANCE

SEIKA SBG3i. SBG3i-B1/B2 & NB3 Acceleration

Certificate of Compliance

Certificate of Compliance

Kotron Model 82 CE RF Level Transmitter

Manostar Electronic Low Differential Pressure Measurement System

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

Level Lance Model 5100

KMS-2 Exia Magnetostrictive Level Transmitter

JM Enclosure Dimensions (in mm)

Product manual wire programmable RTD transmitter

White Paper. Requirements for fieldbus equipment installed in a Zone 2 and Division 2 hazardous area environment. March 24, 2005

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

Power supply. Calibration. Surface finishing. Seal. Process connection

INTRINSICALLY SAFE DUPLEXER

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Loop Powered Indicator

Certificate of Compliance

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

PROline promag 53 Division 1

Fisher 646 Electro Pneumatic Transducer

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

SEIKA SB1i-Inclination

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Intrinsically Safe Compact Controller CTR 210i. Intrinsically Safe Bargraph Indicator. BGI 210i

Rosemount 5400 Series Radar Level Transmitter

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

oxy.iq Panametrics Oxygen Transmitter Applications Features bhge.com Two-wire, loop-powered 4 to 20 ma transmitter An oxygen transmitter for use in:

All TXI7850 products are ROHS compliant.

EN Series Installation Manual

Operating Principles

FLEX Ex Power Supplies

Instruction Manual. Model MLA & MLD Loop Powered Process Indicators IM 61A01A-01E-A. Model MLA (Analog) Model MLD (Digital)

QN5O, QXBO, QNBO, QX7O, QN7O, QXCO, QNCO

ESSENTIAL INSTRUCTIONS Read this page before proceeding!

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters

Design and applications

Rosemount 3101, 3102, and 3105

FLEX Ex V ac In/Quad-Ex dc Out Power Supply

Operating Manual. isolate501

Cyclops User s Manual

Capacitance Level Switch

Installation guide 971 SmartRadar LTi

ST5484E Seismic Velocity 4-20 ma Transmitter Datasheet

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

Positioner with HART Communication Type 3780

Instruction. MI October I/A Series Models 83.-D and -T Vortex Flowmeter Intrinsic Safety Connection Diagrams

[ Rosemount 648 Wireless Temperature Transmitter. Rosemount 648 Wireless. Quick Installation Guide , Rev CA August 2011

ControlNet Ex Tap Terminator Installation Instructions

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Model LD-LPIX EXPLOSION-PROOF LOOP POWERED INDICATOR

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Mid-West. Instrument. Model 142 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

2-wire level transmitter

Intrinsic Safety Control Drawing

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

SEIKA SB2i-B. SB2i B1/B2/B3 & NB3 DC Acceleration. 4-20mA 2 wire output DC Acceleration

Fisher 646 Electro-Pneumatic Transducers

Thie. Automation Products Rev. Chang Date Name Supersedes Dwg. : Part Class:

IECEx Certificate of Conformity Annexe

Fisher 4200 Series Electronic Position Transmitters

Piezotron Coupler. Electronics & Software. Acoustic Emission Coupler for Safe or Hazardous Locations ATEX/IEC/Ex and CSA. Type 5125C...

Installation guide 873 SmartRadar Control Unit & Antenna Unit

Certificate of Conformity

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Binary Output Series 9175

OPTIWAVE 7300 C Supplementary instructions

SEIKA SB2i-NB3 or N2,N3,N4

Installation & Operating Manual. iwap202

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

Fisher LCP100 Local Control Panel

SCS-400. Sealed Parcel Delivery System. Installation Manual

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

IECEx Ex TEST REPORT COVER

Level Measurement Continuous level measurement Radar transmitters

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

TLR wire System Level Radar. MICROWAVE level meter GENERAL FEATURES OPERATION PRINCIPLE

LF Conductivity Measuring Probe

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

1-830 SERIES DISPLACEMENT TRANSMITTER

Transcription:

FF01 Certificate of Compliance Certificate: 1294176 Master Contract: 209996 Project: 1294176 Issued to: Seika Mikrosystemtechnik GmbH Ellharter StraBe 10 D-87435 Kempten GERMANY The products listed below are eligible to bear the CSA Mark shown Issued by: Andrew Redeker, C.E.T. Certification Specialist Authorized by: John Verwey, P.Eng. Operations Manager CLASS 2258 04 - PROCESS CONTROL EQUIPMENT - Intrinsically Safe, Entity - For Hazardous Locations PRODUCTS Class I, Division 1, Groups A, B, C, D; Ex ia IIC T4 SB2i Inclination / Acceleration Sensor; Maximum Ambient 85 C; Temperature Code T4; Enclosure Type 4; Intrinsically Safe with the following Entity Parameters per measurement output; Connections S11, S12 and S21, S22 Vmax, Ui = 30V; Imax, Ii = 78mA; Ci = 24nF; Li = 66uH APPLICABLE REQUIREMENTS CSA Standard C22.2 No 0-M1991 - General Requirements - Canadian Electrical Code Part II. 94-M1991 - Special Purpose Enclosures. 157-M1992 - Intrinsically Safe and Non-Incendive Equipment for Use in Hazardous Locations. CAN/CSA E79-0-02 - Electrical apparatus for explosive gas atmospheres. PART 0: General requirements. E79-11-02 - Electrical apparatus for explosive gas atmospheres. PART 11: Intrinsic safety "i". DQD 507WD 2002/04/30

Supplement to Certificate of Compliance Certificate: 1294176 Master Contract: 209996 The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate. Project Date Description 1294176 July 11, 2002 Original Certification. Product Certification History DQD 507WD 2002/04/30

Descriptive and Test Report Edition 1: July 11, 2002; Project 1294176 - Edmonton Issued by Andrew Redeker, C.E.T. MASTER CONTRACT: 209996 Contents: Certificate of Compliance - Page 1 Supplement to Certificate of Compliance Page 1 Description and Tests Pages 1 to 6 Figures 1 to 7 Illustrations 1 to 3 The test report shall not be reproduced, except in full, without the approval of CSA International.

Page No: 2 CLASS 2258 04 - PROCESS CONTROL EQUIPMENT - Intrinsically Safe, Entity - For Hazardous Locations PRODUCTS Class I, Division 1, Groups A, B, C, D; Ex ia IIC T4 SB2i Inclination / Acceleration Sensor; Maximum Ambient 85 C; Temperature Code T4; Enclosure Type 4; Intrinsically Safe with the following Entity Parameters per measurement output; Connections S11, S12 and S21, S22 Vmax, Ui = 30V; Imax, Ii = 78mA; Ci = 24nF; Li = 66uH APPLICABLE REQUIREMENTS CSA Standard C22.2 No 0-M1991 - General Requirements - Canadian Electrical Code Part II. 94-M1991 - Special Purpose Enclosures. 157-M1992 - Intrinsically Safe and Non-Incendive Equipment for Use in Hazardous Locations. CAN/CSA E79-0-02 - Electrical apparatus for explosive gas atmospheres. PART 0: General requirements. E79-11-02 - Electrical apparatus for explosive gas atmospheres. PART 11: Intrinsic safety "i". MARKINGS (1) Submittor's name, trademark, or the CSA file number (adjacent the CSA Mark). (2) Catalogue / Model designation. (3) Complete Entity Parameters (Vmax, Ui = 30V; Imax, Ii = 78mA; Ci = 24nF; Li = 66uH) (4) Date code / Serial number traceable to month and year of manufacture. (5) Exia, Cl I, Div 1, Gr A,B,C,D, T4 (6) Ex ia IIC T4 (7) The words "INTRINSICALLY SAFE". (9) -40 CTamb85 C (10) CSA Enclosure Type 4 (11) The CSA Mark. ALTERATIONS 1) Markings as noted above 2) The Encapsulation shall completely cover the electronics as per Illustration 3 3) Diode D1 Shall be Diotec P/N S80 (0.8A/160V minimum)

Page No: 3 FACTORY TESTS Dielectric: The equipment at the conclusion of manufacture, prior to shipment, shall withstand for one minute without breakdown, the application of 500 Vac between extra-low voltage circuits and non current carrying parts if such circuits leave or enter the enclosure. NOTES: (1) As an alternative, potentials 20 percent higher may be applied for one second. (2) The required dielectric strength test may be made by applying a dc potential, providing it is 1.414 times the ac test potential. WARNING: The factory test(s) specified may present a hazard of injury to personnel and/or property, and should be performed by persons knowledgeable of such hazards, and under conditions designed to minimize the possibility of injury. DESCRIPTION The SB2i is a pressure die cast aluminum sensor housing with two integrated sensors for measuring inclinations and / or accelerations along two axis. As well as the sensors, the box contains two independent signal conditioners, each with a 4-20mA, 2-wire output and two separate, voltage supplies feeding off of the corresponding current loop, one for each sensor. Furthermore, each signal conditioner includes an active low pass filter, whose upper cut-off frequency / setting time can be adjusted to suit the measurement task, an output stage with current limitation, a noise voltage filter and a diode bridge for unipolar connection to the current loop. Interference signals caused by unwanted ground currents are eliminated by electrically isolating each sensor and signal conditioner from each other and the housing. Refer to Figure 1 for Catalog sheets. Refer to Illustrations 1, 2 and 3 for construction details. ENCLOSURE BASE COVER The base of the enclosure measures approx 63.7mm x 97.7mm x 26mm with a 1.46mm high lip that mates with a groove in the lid that contains a gasket. The base in provided internally with four (4) raised bosses to secure the circuit board. It is also provided with two (2) through holes that can be used to mount the overall equipment. A cable entry is provided in the base for connection of the equipment to the supply circuit. The cable used may be a 3 or 4-wire cable and the cable must be provided with a suitable cable entry gland. The cover of the enclosure measures approx 63.6mm x 97.7mm x 10.2mm with a 2.4mm wide by 3.7 deep o-ring groove. Four (4) screws hold the cover to the base.

Page No: 4 GASKET ELECTRONICS MAIN BOARD SENSORS The gasket is approx 3.3mm in diameter and is placed in the groove cut into the cover. Refer to Figure 2 for Schematic. Refer to Figure 3 for Parts List Refer to Figure 4 for Board Drawings. CRITICAL I.S. COMPONENTS D1/1, D1/2 Diotec P/N S80 (0.8A/160V minimum) C6/1, C6/2, C7/1, C7/2 Capacitor, 10nF ± 20% Maximum L1/1, L2/1, L1/2, L2/2 Chip Inductor 33uH Nominal Potting Compound Wacker, Silicone rubber, RTV-2 (To completely cover all electronics to a minimum depth of 0.5mm ) Refer to Figure 5 for a schematic of the sensors. Any of the following sensors may be installed in the SB2i. B1, B2, B3 See Figure 6 N2, N3, N4 See Figure 7

Page No: 5 TEST REPORT INTRINSICALLY SAFE ANALYSIS ENTITY PARAMETERS Vmax, Ui - Imax, Ii - A maximum voltage of 30Vdc was chosen as this will not invalidate the circuit board spacings under the potting compound. A maximum of 78mA per measurement output was chosen as this will not invalidate the ratings of the protective components. Furthermore, this will limit the maximum power on any given component to less than 0.8W when both measurement outputs are combined. Ci - Ci has been calculated per measurement output as the parallel combination of C6 and C7 + tolerances = 24nF Li - Li has been calculates per measurement output as the series combination of L1 and L2-66H INTERNAL CAPACITANCE - Due to protective bridge diode D1 and the fact that the entire assembly is encapsulated to a minimum depth of 0.5mm above all components, the internal capacitance is not accessible for spark ignition testing. Therefore assessment of the internal capacitance is not requires. INTERNAL INDUCTANCE - Due to protective bridge diode D1 and the fact that the entire assembly is encapsulated to a minimum depth of 0.5mm above all components, the internal inductance is not accessible for spark ignition testing. Therefore assessment of the internal inductance is not requires. PROTECTIVE COMPONENTS - TEMPERATURE CODE RATING - The only protective component is D1. This component has a voltage rating of 160V minimum and a current rating of 0.8A. The maximum I.S. barrier voltage is 30V and combined I.S. barrier current is 156mA. These parameters are less than 2/3 of the nominal ratings of D1. Components L1 and L2 have a nominal resistance of 4 Ohms. With a current of 156mA, these components will dissipate less than 0.1W. Bridge diode D1 will dissipate a maximum of 0.37W (2 * 1.2V * 156mA) under fault conditions. Since the maximum combined I.S. barrier output will be 30V * 156mA / 4 = 1.17W and diode D1 will dissipate 0.37W, this leaves a maximum of 0.8W for all other components downstream of D1. In an 85 C ambient and with the entire circuit board encapsulated, a T4 temperature code rating was deemed acceptable.

Page No: 6 ENVIRONMENTAL PROTECTION TYPE 4 HOSEDOWN Hosedown testing was not performed on a sample of the SB2i as the sample is completely encapsulated and leaves little to no volume for water to enter the enclosure. GASKET COMPRESSION Gasket compression tests not performed as the cover does not need to be removed to make electrical connections. EXTERNAL FORMATION OF ICE There are no external cavities where ice could form. No testing required. CORROSION RESISTANCE Corrosion resistance tests not performed as the enclosure is a painted die cast Aluminum Enclosure. No further testing was deemed necessary