Product tags: VIS, Spectral Data, Color Temperature, CRI, Bilirubin, PAR, Scotopic, Luminous Color, Photometry, General lighting

Similar documents
Product tags: VIS, Spectral Data, Color Temperature, CRI, Waterproof, WiFi, Luminous Color, LED, Photometry, General lighting

BTS256-EF. Product tags: VIS, Spectral Measurement, Waterproof, WiFi. Gigahertz-Optik GmbH 1/7

BTS256-PAR. Product tags: VIS, Spectral Data, PAR, Waterproof, General lighting.

BTS256-E WiFi - mobile light meter for photopic and scotopic illuminance, EVE factor, luminous color, color rendering index and luminous spectrum.

BTS2048-VL-CP-ILED-B-IS-1.0-HL

BTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser.

ISS-30-VA. Product tags: Integrating Sphere Source. Gigahertz-Optik GmbH 1/5

Technological Advances in General Lighting. New Lightmeter for Solid State Lighting. State-of-the-Art LED Illuminance Meter

Spectral Handheld Light Meters for accurate measurements of LED lighting. Mike Clark, Gigahertz-Optik GmbH on behalf of Te Lintelo Systems BV

Spectral Light Meters for accurate measurements of LED lighting Mike Clark, Gigahertz-Optik GmbH

BTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED.

LED Tester BTS256-LED

Spectroradiometer specbos 1201

GL spectis 1.0 Touch The world s first smart spectrometer.

Broadbandradiometer specbos 1211

Luminous Flux (lumens) System LM-ISP-XXXX

HD HD HD AND HD PHOTO-RADIOMETERS LG-2

GL SPECTIS 1.0 Touch The world s first smart spectrometer

LI-192 Underwater Quantum Sensor

Spectral Photometry BASE

Sample Report. IES LM Test Report. LED Lamp 001. Test results reported for: Orb Optronix report: LEDC WG. Original issue date:

INNOVATIVE CAMERA CHARACTERIZATION BASED ON LED LIGHT SOURCE

LED Tester BTS256-LED

LI-193 Spherical Quantum Sensor

Illuminance Meter. series

LP PHOT 03 LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03

MK350 Portable Spectrometer

Photometry and Light Measurement

Photometry for Traffic Engineers...

Miniaturized Spectroradiometer

Photometry for Traffic Engineers...

Horticultural Lighting Test Report

PHOTO RESEARCH, INC. PR-730 / PR-735 and PR-740 / PR-745 SpectraScan

20W TL 324 smd LED Warm White by Simplify-It

Chameleon Spectroradiometer

LED T5 30cm Warm White by BS Ledlight

ANSI/IES TM-33. A New Standard for Luminaire Optical Data

LM-79 Test Report. Electrical and Photometric tests as required by IESNA LM-79 test standard

The Standard for over 40 Years

Guidance Note 3/16 Measurement of the photometric performance of LED lighting

Fully Portable Spectrophotometer for Transmission Measurement

JETI Specbos Instruments

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary

Photometric Test Report

LED14.5WPAR30S/FL/827-DIM

We bring quality to light. MAS 40 Mini-Array Spectrometer

Led Spot MR16 10W Cold White by CDE Technology BV

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

Model S471-LED Optometer

LED Lighting Flux and Color Measurement System (LFC)

INDEPENDENT TEST LABORATORY REPORT No

INDEPENDENT TEST LABORATORY REPORT No

LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03 LP PHOT 03S

There are many types of light sources, ranging from natural sunlight to man-made artificial lightings.

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

LP PHOT LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03 LP PHOT 03S. Light

IESNA LM-79: Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE. Dec 08, 2014

NVLAP LAB CODE:

Radiometric and Photometric Measurements with TAOS PhotoSensors

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: EASZE Page 2 of 14

LM Test Report. For. T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D

GHOLOGRAPHIC COMPANY LIGHT MEASUREMENT SYSTEM

Photometric Test Report

LI-1500 Light Sensor Logger

Horticultural Lighting Test Report

Influence of the light spectral distribution used in the radiometers calibration

High Bay Led Lamp by Glo

Led 12V 3W Spot Light GU5.3 by Tuono Lighting

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a. 60 mins Note. 4000K, frosted lens Table 1: Executive Data Summary

Properties of LED considering museum lighting

High Precision CCD Spectroradiometer & Integrating Sphere Test System LPCE-2(LMS-9000B) Brochure. Global Office of Lisun Electronics Inc.

Report No.: HZ d

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

Measurement Services Optics Laboratory

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

RGB Laser Meter TM6102, RGB Laser Luminance Meter TM6103, Optical Power Meter TM6104

Instruction manual for Ocean Optics USB4000 and QE65 Pro spectroradiometers

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

NVLAP LAB CODE:

LM Test Report

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

IESNA LM-79: Measurement and Test Report for Jiawei Technology (USA) Limited Lincoln Ave.Hayward, CA USA.

Led Spot MR16 10W Neutral White with 700 ma constant current driver by CDE Technology BV

operating manual iliad for Windows & Mac OS X software application rc81

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

Optometers & Instruments - Page 3

NVLAP LAB CODE:

True energy-efficient lighting: the fundamentals of lighting, lamps and energy-efficient lighting

Led Tube Light KLV-T8-121-WA by KLV Ledverlichting

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC. Sep 09, 2013 LED8WMR16/38/830-DIM. David Zhang BTR

IESNA LM-79: Measurement and Test Report for Green Creative Ltd. Room , New Victory House, Wing Lok Street, Central, HONG KONG

Lighting Terminologies Introduction

NVLAP LAB CODE:

NVLAP LAB CODE:

Transcription:

MSC15 http://www.gigahertz-optik.de/en-us/product/msc15 Product tags: VIS, Spectral Data, Color Temperature, CRI, Bilirubin, PAR, Scotopic, Luminous Color, Photometry, General lighting Gigahertz-Optik GmbH 1/7

Description LEDs enable much greater control of the lighting quality than the technologies they are rapidly replacing. Many international standards now specify requirements for internal and external lighting systems in terms of both quality and quantity of light as well as in terms of efficiency and life time. Photometry in the lighting industry generally focuses on the intensity (i.e. illuminance) and color (i.e. correlated color temperature CCT and color rendering index CRI) of light falling on a surface. LED lamps are extremely versatile in terms of emission spectra, which is why spectral measurement of the illuminance and color has now become essential for any high-end light meters. The MSC15 compact, handheld, and low cost The MSC15 from Gigahertz-Optik GmbH is a modern light meter whose technical concept allows for precise measurement of the illuminance spectrum, color, and color rendering. Its cutting-edge design concentrates on measurement accuracy rather than unnecessary esoteric electronic features which results in a high quality meter for an attractive price. The light sensor consists of a fast spectroradiometer that covers a spectral range between 360 nm and 830 nm (V-lambda range according to CIE S023) with a spectral bandwidth of 10 nm. The device also integrates an optical bandwidth correction feature (CIE 214) in order to further improve the quality of the values calculated based on the spectral measurement data. Another key feature that ensures accurate illuminance measurements of extended lighting conditions is its carefully designed field of view. Accurate illuminance measurements are only possible with a precise, cosine-corrected entrance optic. The MSC15 has an excellent cosine response (f2 3 %), at the same time as offering a wide measurement range for illuminance and color between 1 lx and 350,000 lx. The colored touch screen of the device makes it extremely easy to use. Uninterrupted operation of more than 8 hours is provided by its lithium ion battery which is recharged via the USB 2.0. Remote control of the device and data read out are made possible by the supplied software. MSC15 for measurement of the illuminance, spectrum, color, and color rendering in the lighting industry Calibration of the MSC15 One essential quality feature of photometric devices is their precise and traceable calibration. The MSC15 is calibrated by Gigahertz-Optik s calibration laboratory that is accredited by DAkkS (D-K-15047-01-00) for the spectral responsivity and spectral irradiance according to ISO/IEC 17025. Every device is supplied with its respective calibration certificate. Additional functions of the MSC15 The MSC15 also includes additional functions for use in specialist fields of lighting. Touchscreen for intutive handling of the meter LED grow lights need to be measured in terms of the Photosynthetically Active Radiation (PAR) they produce. An additional function of the MSC15 is the display of Photosynthetic Photon Flux Density (PPFD) in µmol/m²s (400 nm to 700 nm) which is a measure of the total number of photons within the PAR wavelength range that reach a surface each second per square meter area. Neonatal phototherapy lamps used for the treatment of hyperbilirubinemia can be accurately measured in accordance with the latest standards and guidance, irrespective of the lamp type or manufacturer. The MSC15 directly displays total irradiance for bilirubin, E bi (mw/cm 2 ) in accordance with IEC 60601-2-50:2009+A1:2016 as well as average spectral irradiance (µw/cm 2 /nm) in accordance with the latest American Academy of Pediatrics recommendations. Display of photopic lux, CCT and CRI Ra Human Centric Lighting requires new metrics beyond traditional photometric and colorimetric values (ref. CIE TN 003:2015). The MSC15 Gigahertz-Optik GmbH 2/7

directly displays melanopic irradiance, melanopic illuminance (equivalent melanopic lux) and melanopic daylight equivalent illuminance. Options for the MSC15: - Software development kit for integration of the device in the user s own software Display of the spectral power distribution, photopic lux and CCT Display of the CRI's Display of photopic and scotopic lux and their ratio. Display of melanopic lux, etc. according to CIE TN 003: 2015 and Well building Standard Gigahertz-Optik GmbH 3/7

Display of PAR and the spectral power distribution Display of Bilirubin according IEC 60601-2-50 and the spectral power distribution Display of Bilirubin according AAP and the spectral power distribution Gigahertz-Optik GmbH 4/7

CIE 1931 view Example measurement in the MSC15's software Specifications General Short description Main features Range of measurement Typical applications Calibration Spectroradiometer for measurement of the illuminance, spectrum, light color, and color rendering Mobile meter, spectroradiometer with a 10 nm optical bandwidth and additional optical bandwidth correction (CIE214), precise cosine field of view function, Lithium ion battery with over 8 operation hours 1 lx to 350,000 lx, 360 nm to 830 nm Precise spectral light meter for the lighting industry Factory calibration. Traceable to international calibration standards Product MSC15 Handheld meter for illuminance and light color. Color-Touchscreen, simple intuitive Operation with clearly arranged display views. (Class B according DIN 5032-7 or AA according to JIS C 1609-1:2006) Measurement Quantities Illuminance photopic Illuminance scotopic Spectral Irradiance Color coordinates (x,y) CCT CRI (color rendering index) PAR PPFD Melanopic irradiance Melanopic illuminance (equivalent melanopic lux) Melanopic daylight equivalent illuminance Total irradiance for bilirubin (E bi ) Average spectral irradiance for bilirubin (AAP) Entrance Optic Diffuser window with 10mm diameter, cosine corrected field of view, f2 3 % Spectral Detector Wavelength Range (360-830) nm Optical Bandwidth 10 nm optical bandwidth correction applied according to CIE 214 Measurement range typ. white LED (1-350000) lx Gigahertz-Optik GmbH 5/7

Gigahertz-Optik GmbH 6/7

Powered by TCPDF (www.tcpdf.org) Δx, Δy reproducibility ± 0.0002 Δx, Δy uncertainty ± 0.002 (Standard illuminant A) CCT Measurement range (1700-17000) K ΔCCT ± 50K (standard illuminant type A) ± 4% (depending on the LED spectrum) Calibration Calibration uncertainty Illuminance (standard illuminant A) +/- 3% Illuminance (typ. LED) +/- 4% (Traceable to national standard. Uncertainty of the standard is included) Miscellaneous Interface USB 2.0 Temperature Range Operation: 10 C to +30 C Storage: -10 C to +50 C Power rechargeable battery minimum 8h of operation Charging voltage Display Weight Dimensions 5VDC by USB Color Touchscreen 160 g 136 mm x 74 mm x 32 mm Purchasing information Article-Nr Modell Description Product 15298960 MSC15 MSC15 measurement device, USB cable, case for device and USB cable, SMSC15 Software, calibration, calibration certificate Re-calibration 15300569 K-MSC15-I Calibration of the MSC15 including wavelength adjustment. Calibration certificate Software 15306347 S-SDK-MSC15 Software development kit Gigahertz-Optik GmbH 7/7