I. INTRODUCTION II. LITERATURE REVIEW

Similar documents
REACTIVE POWER COMPENSATION IN DISTRIBUTION SYSTEM

Four Quadrant Speed Control of DC Motor with the Help of AT89S52 Microcontroller

CHAPTER 2 VSI FED INDUCTION MOTOR DRIVE

Development of Tsunami early warning embedded system with GSM alert

Design and Implementation of AT Mega 328 microcontroller based firing control for a tri-phase thyristor control rectifier

Induction Motor Protection using Micro Controller

Auto Density Sensing Traffic Control System using At89s52

Implementation of Single Phase Transformer less Inverter for Grid-Tied Photovoltaic System with Reactive Power Control

SYNOPSIS ON. Bachelor of Technology In Electronics & Communication

Design and Implementation of Economical Power Factor Transducer

Minimizing Penalty In Industrial Power Consumption By Engaging Apfc Unit

Seminar Report Railway Gate Control 1. INTRODUCTION

Power Factor Compensation Using PIC

Design and Development of Train Tracking System in South Central Railways

Implementation of Multiquadrant D.C. Drive Using Microcontroller

Modeling, Simulation and Implementation of Speed Control of DC Motor Using PIC 16F877A

Houngninou 2. Abstract

M.Sinduja,S.Ranjitha. Department of Electrical & Electronics Engineering, Bharathiyar Institute of Engineering For Women, Deviyakurichi.

A Single Phase Power Factor Correction Using Programmable Interface Circuit

Cortex-M3 based Prepaid System with Electricity Theft Control

Auto-Fact Security System

Design and Implementation of Bridge PFC Boost Converter

Power Factor Improvement Using Thyristor Switched Capacitor Using Microcontroller Kacholiya Saurabh 1, Phapale Sudhir 2, Satpute Yuvraj 3, Kale.S.

Design Of Low-Power Wireless Communication System Based On MSP430 Introduction:

DESIGN AND DEVELOPMENT OF A LOW-COST MICROCONTROLLER BASED SINGLE PHASE WATER-PUMP CONTROLLER

Power Factor Improvement Using Static VAR Compensator

Automatic Load Sharing of Transformers using Microcontroller

ADVANCED SAFETY APPLICATIONS FOR RAILWAY CROSSING

MICROCONTROLLER BASED SPEED SYNCHRONIZATION OF MULTIPLE DC MOTORS IN TEXTILE APPLICATIONS

RF Based Pick and Place Robot

Monitoring And Control Over Power Factor By Using Pic Micro-Controller

International Journal of Advance Engineering and Research Development

GSM BASED ENERGY THEFT MONITORING SYSTEM

International Journal of Advance Engineering and Research Development. Wireless Control of Dc Motor Using RF Communication

LM555 and LM556 Timer Circuits

DESIGN ANALYSIS AND REALIZATION OF MICROCONTROLLER BASED OVER CURRENT RELAY WITH IDMT CHARACTERISTICS: A PROTEUS SIMULATION

6. HARDWARE PROTOTYPE AND EXPERIMENTAL RESULTS

The Guitar Chord Learning System

International Journal of Advance Engineering and Research Development

CHAPTER 6 IMPLEMENTATION OF FPGA BASED CASCADED MULTILEVEL INVERTER

Control of Electrical Lights and Fans using TV Remote

Microcontroller Based Automatic Control Home Appliances

School of Electronic Science and Engineering, Nanjing University of Posts and Telecommunications, Nanjing, , China

Simulation & Realization of Feeder Protection with Micro Controller

Automatic Power Factor Correction by Using Synchronous Condenser with Continuous Monitoring.

International Journal of Applied Sciences, Engineering and Management ISSN , Vol. 06, No. 02, March 2017, pp

ABSTRACT I. INTRODUCTION. D. Meena 1, Saravanan. S 2, Bharanidharan.P, 3 Aravinth.S 4

GSM BASED PATIENT MONITORING SYSTEM

Screening Audiometer

Digital Monitoring Cum Control of a Power Transformer with Efficiency Measuring Meter

Auto Selection of Any Available Phase in 3 Phase Supply System

Management of Home Appliances with Variation in Environment Aisha Jilani, Sahar Sultan, Intesar Ahmed and Sajjad Rabbani

IGBT based Multiport Bidirectional DC-DC Converter with Renewable Energy Source

Index Terms-Emergency vehicle clearance, Higher density, IR sensor, Micro controller, RFID Technology.

International Journal of Advance Engineering and Research Development

A DUAL SERIES DC TO DC RESONANT CONVERTER

GSM Based Device Controlling and Fault Detection

The Development and Application of High Compression Ratio Methanol Engine ECU

Prashant Sangulagi Assistant Professor, E&CE Dept. BKIT Bhalki, INDIA

The Speech Based Floor Cleaning Robot

CHAPTER ONE INTRODUCTION

Implementation of Modern Vigilance Control Device Using GSM and GPS Technology M.Sindhuja 1 J.Suresh 2

POWER FACTOR IMPROVEMENT USING OPEN LOOP FEEDBACK STATIC VAR COMPENSATOR (SVC)

AC POWER CONTROL USING ANDROID CELLPHONE WITH LCD DISPLAY

II. L-Z SOURCE INVERTER

LM125 Precision Dual Tracking Regulator

Programming and Interfacing

High Speed PWM Controller

Micro-controller Based Three-phase Voltage Source Inverter for Alternative Energy Source. Abstract

Simulation & Hardware Implementation of APFC Meter to Boost Up Power Factor Maintain by Industry.

GROUP NO:-19 SWARUP HARICHANDAN SATYA PRAKASH PRADHAN SUBHENDU KUMAR TARAI DHANANJAYA NAYAK SUCHISMITA DAS MANOJ KUMAR MOHANTY

THE PERFORMANCE TEST OF THE AD CONVERTERS EMBEDDED ON SOME MICROCONTROLLERS

Prototype design of power factor correction circuit for transmission lines using Thyristor switched capacitor scheme

International Research Journal in Advanced Engineering and Technology (IRJAET)

Electronic Components

Intelligent Traffic Light Controller

2.0 Discussion: 2.1 Approach:

ARDUINO BASED POWER FACTOR CORRECTION

Voltage Variation Compensation

Micro Controller Based Ac Power Controller

Power Factor Correction Using SCR and Microcontroller

War Field Spying Robot With Night Vision Camera

HUMANOID ROBOT FOR REMOTE SURVEILLANCE

Design of LVDT Based Digital Weighing System

Automated Load Distribution with Password Protected Circuit Breakers

3 Circuit Theory. 3.2 Balanced Gain Stage (BGS) Input to the amplifier is balanced. The shield is isolated

DESIGN OF TEMPERATURE BASED SPEED CONTROL SYSTEM USING ARDUINO MICROCONTROLLER

PIC based Frequency and RMS Value Measurement

Generation of PWM Inverter Based on a Microcontroller at Feeding Induction Motor

Microcontroller Based MPPT Buck-Boost Converter

Normally, digital speedometers

High Speed PWM Controller

International Journal of Advance Engineering and Research Development

A Novel Hidden Camera Destroyer Using EMP

[Ahmed, 3(1): January, 2014] ISSN: Impact Factor: 1.852

INTELLIGENCE HOME AUTOMATION SYSTEM USING LDR

International Journal of Innovations in Engineering and Technology (IJIET) Nadu, India

Transformer Health Condition Monitoring Through GSM Technology

DTMF Controlled Robot

VOLTAGE MULTISTABILITY FOR DISTRIBUTION SYSTEM

Transcription:

ABSTRACT 2018 IJSRSET Volume 4 Issue 4 Print ISSN: 2395-1990 Online ISSN : 2394-4099 Themed Section : Engineering and Technology Reactive Power Compensation in Distribution System Piyush Upadhyay, Praveen Nagar, Priya Chhaperwal, Rajat Agarwal, Sarfaraz Nawaz Department of Electrical Engineering, SKIT M& G, Jaipur, Rajasthan, India In this paper, a reactive power compensation system is presented where inductor plays a major role for developing the lagging condition. Reactive power variations have an effect on the generating systems, lines, circuit-breakers, transformers, relays and isolators. Due to this there is an effective voltage sags and increased losses. In the proposed system, voltage and current pulse lead time are given to the interrupt pins of the microcontroller in which the fed program helps to bring the shunt capacitors in circuit for the reactive power compensation. Based on the delay the program fed in the microcontroller brings the result which gives the number of relays using relay driver IC from its output to connect shunt capacitors into the load circuit till the power factor reaches nearest to unity. Keywords: VAR compensator, power factor, Reactive Power Compensator I. INTRODUCTION Since it has become mandate to increase the availability of electrical power because of its increasing demand, the energy efficiency is a topic that has been turned out to be more and more protruding. The available voltage at the consumer ends gets reduced with the introduction of inductive loads in the power system by the customers. With increase in reactive power, the load current also gets increased and hence the utility has to supply to the inductive load. This in turn cuts down the efficiency and increases the system losses of the power system. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers by applying penalties where there is a low power factor at the load side because of the significant reactive power. This problem can be alleviated by an extensively used approach that is through the use of corrective capacitors. Reactive power can be supplied by use of capacitors, and hence gives the required reactive power to the inductive loads. Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. II. LITERATURE REVIEW In practical operation of transmission systems, the voltage needs to be continuously monitored and controlled to compensate for the daily changes in load, generation and network structure. In fact, the control of voltage is a major issue in power system operation. Kundur (1994). It identifies the main objectives of voltage control as: Voltage at the terminals of all equipment in the system should be kept within acceptable limits, to avoid malfunction of and damage to the equipment. Keeping voltages close to the values for which stabilizing controls are designed, to enhance system stability and allow maximal utilization of the transmission system. Minimize reactive power flows, to reduce active as well as reactive power losses whereas distribution systems as a rule are operated in radial configuration. Consequently, more sophisticated control schemes than those used in distribution systems are necessary. IJSRSET1844460 Received : 10 April 2018 Accepted : 23 April 2018 March-April-2018 [(4) 4 : 1301-1305] 1301

To get the minimum operating cost with the increased efficiency for the electrical power received by the consumers at the load ends, development of optimum solution was initiated (Kichmayer 1958). Network Resistor 10 K Ω Voltage Regulator 7805 IC Base 16 Pin Transformer 12-0-12 V/ 500 ma Narita et al (1971) using the method of base optimization technique for the minimization of voltage deviation and reduce the system losses developed the sensitivity analysis. They used voltage and reactive power regulating devices to obtain successful operation by installing them at various points. Table 1 Component Rating Micro- controller Atmel AT89S52 Figure 1. Block diagram of reactive power compensation technique LCD Quad Comparators IC LED Choke Relay Electrolyte Capacitors Ceramic Capacitor Crystal Oscillator Diodes Resistors Variable Resistor 16 x 2 Character LM339 Red 250V/40W 12 V 10uF/50V 2200 uf/25v 1000 uf/25v 33pF 11.0592 MHz 1N4007 100 K Ω 47 K Ω 10 K Ω 1 K Ω 4.7 K Ω 100 Ω 10 K Ω III. COMPONENT DETAILS 3.1 MICROCONTROLLER AT89C52 (8051 Family) The AT89S52 is a low-power, high-performance CMOS 8-bit microcontroller with 8K bytes of insystem programmable Flash memory. The device is manufactured using Atmel s high-density nonvolatile memory technology and is compatible with the industry- standard 80C51 instruction set and pin out. The on-chip Flash allows the program memory to be reprogrammed in-system or by a conventional non-volatile memory programmer. By combining a versatile 8-bit CPU with in-system programmable Flash on a monolithic chip, the Atmel AT89S52 is a powerful microcontroller which provides a highlyflexible and cost-effective solution to many embedded control applications. The AT89S52 provides the following standard features: 8K bytes of Flash, 256 bytes of RAM, 32 I/O lines, Watchdog timer, two data pointers, three 16-bit timer/counters, a six-vector two-level interrupt architecture, a full duplex serial port, on-chip oscillator, and clock circuitry. 1302

3.2 Liquid Crystal Display (LCD) Controller The HD44780U dot-matrix liquid crystal display controller and driver Logical System Integration (LSI) displays alphanumeric, Japanese kana characters, and symbols. It can be configured to drive a dot-matrix liquid crystal display under the control of a 4- or 8-bit microprocessor. Since all the functions such as display RAM, character generator, and liquid crystal driver, required for driving a dot-matrix liquid crystal display are internally provided on one chip. 3.3 RELAY A relay is an electrically operated switch. Many relays use an electromagnet to operate a switching mechanism mechanically, but other operating principles are also used. Relays are used where it is necessary to control a circuit by a low-power signal (with complete electrical isolation between control and controlled circuits), or where several circuits must be controlled by one signal. The first relays were used in long distance telegraph circuits, repeating the signal coming in from one circuit and re-transmitting it to another. Relays were used extensively in telephone exchanges and early computers to perform logical operations. 3.4 Low Power Low Offset Voltage Quad Comparator LM 339 The LM339 is consists of four independent voltage comparators that are designed to operate from a single power supply over a wide range of voltages. Operation from dual supplies also is possible, as long as the difference between the two supplies is 2V to 36V, and VCC is at least 1.5V more positive than the input common-mode voltage. Current drain is independent of the supply voltage. The outputs can be connected to other open-collector outputs to achieve wired-and relationships. pass. Negative voltage regulators are available, mainly for use in dual supplies. Most regulators include some automatic protection from excessive current ('overload protection') and overheating ('thermal protection'). Many of the fixed voltage regulator ICs has 3 leads and look like power transistors, such as the 7805 +5V 1A regulator shown on the right. They include a hole for attaching a heat sink if necessary. IV. PROJECT IMPLEMENTATION The LCDs and microcontroller ports are initialised first along with the output voltage rating to determine the improved power factor. Change in phase angle is determined by comparing the values of CT and PT. If the calculated power factor is less than 0.9 lag or greater than 0.1 lead the current through the capacitor is varied by the application of relays which sense the current variation. Thus, the capacitor is added in the circuit and the reactive power is compensated. This process goes on whenever the supply is given. Power to the circuit is fed from a step-down transformer where a rectifier is used for converting AC-DC and regulated. The time lag between the zerovoltage pulse and zero current pulse duly generated by suitable operational amplifier circuits in comparator mode are fed to two interrupt pins of the 8051 microcontroller. The time lag between the current and voltage are displayed on LCD which is interfaced with microcontroller. Depending upon the delay the program which has been dumped in the microcontroller brings appropriate number of relays through relay driver IC from its output to bring shunt capacitors into the load circuit to get the power factor, till it reaches nearest to unity. 3.5 Regulator Voltage regulator ICs are available with fixed (typically 5, 12 and 15V) or variable output voltages. They are also rated by the maximum current they can 1303

CIRCUIT DIAGRAM through relay driver IC from its output and hence capacitor get connected according to the requirement for the compensation purpose. VI. FUTURE SCOPE PROJECT OVERVIEW Figure 2 This being the initial stage for reactive power compensation many improvements can be done further by using the FACT devices. Further the paper can be enhanced by using thyristor control switches instead of relay control to avoid contact pitting often encountered by switching of capacitors due to high rush current. We can also add the novel technique to find the allocation of capacitor in the distribution line. VII. REFERENCES Figure 3 V. CONCLUSION research and experimental work has been conducted successfully and such a setup is designed which is helpful in reactive power compensation at the distribution ends. It is capable to bring shunt capacitors into the load circuit to get the power factor, till it reaches nearest to unity. It is known that transmission losses are reduced to over 2-3% but the distribution losses are still there up to 27%, so by compensating the reactive power a lot can be done in getting the losses down. The time lag between the current and voltage are displayed on LCD along with the power factor compensated which is interfaced with microcontroller. Depending upon the delay the program which has been dumped in the microcontroller brings appropriate number of relays [1]. M.D.Ruhul Amin, Design of Microcontroller Based Thyristor Controlled Three-Phase Static Volt-Ampere Reactive Compensator, 3rd International Conference on Informatics, Electronics & Vision, 2014. [2]. A. Gelen and T. Yalcinoz, Three-Phase System with Static and Dynamic Loads, IEEE [3]. Taufik and Bryan Paet, a Small Scale Static VAR Compensator for Laboratory Experiment,2nd IEEE International Conference on Power and Energy (PECon 08), December 1-3, 2008. [4]. J. Glover, M. Sarma, and T. Overbye, Power System Analysis and Design, 4th ed., Toronto: Thomson 2008. [5]. C. L. Wadhwa, Electrical Power Systems, New Age International Publishers, 2009 [6]. Hadi Saadat, Power System Analysis,WCB McGraw Hill, 1999. Authors Biography Dr. Sarfaraz Nawaz, associate professor in SKIT, Jaipur in electrical engineering. 1304

Priya Chhaperwal, pursuing B. Tech from SKIT, Jaipur in electrical engineering. Rajat Agarwal, pursuing B. Tech from SKIT, Jaipur in electrical Engineering. Piyush Upadhyay, pursuing B. Tech from SKIT, Jaipur in electrical engineering. Praveen Nagar, pursuing B. Tech from SKIT, Jaipur in electrical engineering. 1305