Product Information. Introduction

Similar documents
GenePix Application Note

ScanArray Overview. Principle of Operation. Instrument Components

In our previous lecture, we understood the vital parameters to be taken into consideration before data acquisition and scanning.

GenePix Application Note

Scanning and Image Processing -by Steve Clough

NPTEL VIDEO COURSE PROTEOMICS PROF. SANJEEVA SRIVASTAVA

EmbryoCellect. RHS Scanning and Analysis Instructions. for. Genepix Pro Software

Quality control of microarrays

Products - Microarray Scanners - Laser Scanners - InnoScan 900 Series and MAPIX Software

Scan slides (Axon Genepix 4200AL)

Standard Operating Procedure

Instructions for Howto Scan µarrays

Microarray Data Pre-processing. Ana H. Barragan Lid

Scanning Archival Images

NPTEL VIDEO COURSE PROTEOMICS PROF. SANJEEVA SRIVASTAVA

BD FC Beads 7-Color Kit

Before you start, make sure that you have a properly calibrated system to obtain high-quality images.

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION

Development of a Next-Generation Laser-Scanner System for Life Science Research

BD FC Beads 7-Color Kit

Bruker Dimension Icon AFM Quick User s Guide

University of Wisconsin Chemistry 524 Spectroscopic Components *

Image Capture TOTALLAB

MAKE SURE YOUR SLIDES ARE CLEAN (TOP & BOTTOM) BEFORE LOADING DO NOT LOAD SLIDES DURING SOFTWARE INITIALIZATION

Bruker Dimension Icon AFM Quick User s Guide

LSM 710 Confocal Microscope Standard Operation Protocol

Experiment G: Introduction to Graphical Representation of Data & the Use of Excel

Leica SP8 Resonant Confocal. Quick-Start Guide

HF Upgrade Studies: Characterization of Photo-Multiplier Tubes

IncuCyte ZOOM Fluorescent Processing Overview

Anatomix RP X-Ray System

Point Calibration. July 3, 2012

LSM 780 Confocal Microscope Standard Operation Protocol

Automatic gene expression estimation from microarray images. Daniel O. Dantas Adviser: : Junior Barrera

Experiment 1: Fraunhofer Diffraction of Light by a Single Slit

Swept-Field User Guide

Ratio Imaging. Dividing one image by another to detect changing conditions. Images collected at different times, wavelengths, polarities, etc

RD-90 Developer-Replenisher F-Fix Fixer-Replenisher

Anatomix Plus X-Ray System

Best Practice in Photo tooling. Eric Janssens Februari 2016

Cytell Cell Imaging System

Camera Test Protocol. Introduction TABLE OF CONTENTS. Camera Test Protocol Technical Note Technical Note

Instructions for Mapping * µarray Images using GenePix 5.0

Select-a-Size DNA Clean & Concentrator MagBead Kit Catalog No. D4084 & D4085

Fluorescence Imaging of Single Spins in Nitrogen-Vacancy centers using a Confocal Microscope. Advanced Lab Course University of Basel

KODAK PROFESSIONAL ELITE Chrome 200 Film

Image and Data Acquisition

1 Placing particles on the slide

SOP-P094. BioMek 2000 Compound Protocol Cyan/Hypercyt + Analysis

Quick Guide. NucleoCounter NC-3000

RPF & OPF Technical Information

Student Laboratory Investigation The Chemistry of Combustion and Respiration. Investigation Procedure:

Preparation of Sample Hybridization Scanning and Image Analysis

ZEISS LSM 710 CONFOCAL MICROSCOPE USER MANUAL

UNIVERSITY OF WATERLOO Physics 360/460 Experiment #2 ATOMIC FORCE MICROSCOPY

Developed by BioDiscovery, Inc. DualChip evaluation software User Manual Version 1.1

Leica TCS SP8 Quick Start Guide

Troubleshooting Guide for Digital Printing on Creative Papers

Please follow these instructions for use of the Philips CM100 TEM. Adopted from website below.

In the Heat of the Light

ab Firefly Cytometer Setup Particles

FEI Tecnai G 2 F20 Operating Procedures

Polymer Plate Development Procedures. (800) or (802) (800)

Why and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev. Microscopy course, Michmoret Dec 2005

Microscopy. The dichroic mirror is an important component of the fluorescent scope: it reflects blue light while transmitting green light.

DOSELAB TOMOTHERAPY TG-148 QA QUICK GUIDE TG-148 RECOMMENDED TESTS 1. V.B.1.C. - Y-JAW DIVERGENCE/BEAM CENTERING

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS

METALWORKS TARTAN PANELS General Installation Instructions

Developing a novel method for the screening of fungal germinated spores using hydrogel microencapsulation and large particle flow cytometry.

GafChromic EBT2 and EBT3 Films for Ball Cube II Phantom

GAFCHROMIC HD-810 Radiochromic Dosimetry Film Configuration, Specifications and Performance Data

MOLD INSTRUCTION MANUAL

- Water resistant. - Large size.

ILFORD FP4 PROCESS CONTROL STRIPS & FILM PROCESS CONTROL

LASER SAFETY. Lasers are part of everyday life and most households currently have them built in to many devices such as DVDs, CDs and computers.

Diabetic Retinopathy Clinical Research Network (DRCR.net) UWF Optos Imaging Protocol. Version /14/14

Cold curing adhesive K-X280

DIC Imaging using Laser Scanning Microscopes (LSMs) on Axio Imager Stands

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

Leica TCS SP8 Quick Start Guide

OPTICS AND LASER PHYSICS LABORATORY #10 INSIDE A LASER CAVITY -- EXPLORING STABILITY, POLARIZATION, AND MODES with Mark Chawla and Chris Baird

Training Guide for Carl Zeiss LSM 5 LIVE Confocal Microscope

Microscopy from Carl Zeiss

Calculating AC Line Voltage Rise for IQ-Series Micros with Q Cable

Label Studio Quick Start Guide

FluorCam PAR- Absorptivity Module & NDVI Measurement

Practical work no. 3: Confocal Live Cell Microscopy

RAITH e-line OPERATING INSTRUCTIONS

Setting up and Using Digital Micrometer Controlled Lapping Fixtures

v1.0.1 March AlphaLab, Inc. All rights reserved. TriField EMF Meter Owner s Manual

REAL-TIME DUST MONITOR FOR INDOOR AIR QUA- LITY MEASUREMENTS AND WORKPLACE EXPOSURE ASSESSMENTS FIDAS

Gravitational Lensing Experiment

How is the Digital Image Generated? Image Acquisition Devices

Module 2: Glycan Array Printing & Analysis. 2. Print slides on contact microarray printer, perform post-printing immobilization and blocking

Ambient Light Rejecting Fixed Frame Screen. (3.9 width frame) User s Guide

GALILEO TMA CK 4500 HTS Tissue Microarray Platform

Standard Operating Procedure for the Amray 1810 Scanning Electron Microscope Version: 29 NOVEMBER 2014

WELCOME TO LIFE SCIENCES

DIC Imaging using Laser Scanning Microscopes (LSM) on Inverted Stands

Transcription:

Microarray Scanner Calibration Slide To quantitatively analyze scanners performance and output, adjust and fine-tune scanners, and perform comparative analysis for multiple scanner units. To verify scanners performance periodically. Product Information Product name cat.number Scanner Calibration Slide FP-AW390A, 1Unit Specification - Slide size: 3 x 1 x 1 mm - Array dimensions: 2 blocks; each block contains 32 columns x 12 rows - Spot center-to-center distance: 350 μm Storage: The slide is packaged in an air and moisture resistant foil bag. Once opened, the slide should be kept away from light. When not in use, please store the slide desiccated in the dark. Introduction The Microarray Scanner Calibration Slide has been developed for users to perform quantitative evaluations of their microarray scanners. It is designed for determining the dynamic range, limit of detection, and uniformity of microarray scanners. It is also an excellent tool for detecting laser channel-to-channel cross-talk and laser stability. This slide contains two separate blocks of arrays in dilution series of Cy3 and Cy5 fluorescent dyes. Each block consists of 28 sets of two-fold dilutions of Cy3 or Cy5, coupled with 3 sets of blanks and one set of position markers. Each column contains 12 repeats of each sample. See page 13 for Array Layout. Applications Analyze and calculate microarray scanners dynamic range and limit of detection Detect and analyze performance variations among different microarray scanner units Detect channel-to-channel cross-talk Verify laser alignment and focus Handling Directions for use It is highly recommended to wear gloves when handling the slide. Handle the slide by holding the slide edges or the area with the bar-code label. Do not touch the slide surface. Do not attempt to clean or wash the slide with any chemicals. If dust particles are found on the slide surface, clean the surface by blowing a gentle stream of compressed nitrogen (industrial grade or above) with a pressure of 20psi or less. Do not use canned compressed air. Avoid exposing the slide to light. When finished with each scan, keep the slide in a container to protect it from light and dusts. P.1

Protocol 1) Carefully remove the slide from the slide box. The arrays are to be found on the same side of the slide where the bar-code label is located. 2) Load the slide on a microarray scanner s slide holder. 3) Perform a quick scan to locate the arrays on the slide. 4) Adjust appropriate settings and parameters on the scanner, and proceed to scan the arrays. 5) Using data provided in Table 1.1 (Appendix B), perform necessary analyses. 6) Follow the detailed protocols provided in this data sheet for suggested applications, or use the device accordingly for applications of your interests. Guidelines for suggested applications A. Limit of detection Typically, the limit of detection (LOD) is defined as the minimum detectable signals for which the signal-tonoise ratio (SNR) is 3. The sensitivity of a scanner is inversely related to the limit of detection the detection sensitivity increases as the limit of detection decreases. Knowing the limit of detection before starting a microarray experiment allows researchers to determine the minimum sample concentration needed for the experiment, in turn maximize research efficiency. To determine SNR, the following formula is commonly used: 2) Optimize PMT, laser power, and gain settings so that saturated signals are observed for the spots in the last 4 to 6 columns on the far right side of the array, where the CyDye concentrations are high. 3) Scan the arrays with both red and green lasers. 4) Analyze the image and calculate the signal-to-noise ration (SNR) for each column of the arrays. 5) Identify the corresponding column for which the SNR value is equal to or larger than 3. 6) Using Table 1.1 (Appendix B), determine the number of fluorophores/um2 for the column identified in Step 5. This number is the limit of detection for the scanner. B. Dynamic Range A scanner s dynamic range is referred to as the linear response range of a system, which helps researchers to optimize sample concentrations in a microarray experiment. 2) Optimize PMT, laser power, and gain settings so that saturated signals are observed for the spots in the last 4 to 6 columns on the far right side of the array, where the CyDye concentrations are high. 3) Analyze the image and calculate the signal-to-noise ratio (SNR) for each array column. 4) Plot, in logarithm scale, the SNR data against the number of fluorophores/um 2 for each column, data provided in Table 1.1 (Appendix B). 5) Using the graph, locate Point A, which has a SNR value of 3, and Point B, which is the end point of the plotted line s linear portion, i.e., the point at which the line begins to plateau. Find the corresponding number of fluorophores/um 2 for the two points. These two numbers constitute the two end points of the linear dynamic response range of your system. P.2

Note: An example graph plot is provided below. The linear dynamic ranges for common biological experiments are approximately 3 to 3.5. C. Channel cross-talk Channel cross talk is a phenomenon where signals from one channel leak into another channel. Because cross talk phenomenon may be concealed in a dual-color image, the effect is less noticeable for users when they scan arrays hybridized with both dyes, with red and green lasers simultaneously. 2) Optimize PMT, laser power, and gain settings. 3) Activate the red laser only. Scan both sets of arrays. Save the acquired image as Image A. 4) Turn off the red laser, and turn on the green laser. Scan both sets of arrays, and save the acquired image as Image B. 5) Analyze Image A and Image B, calculate the intensity of Cy3 and Cy5 signals from both scans, and determine the percentage of the channel cross talk. D. Alignment and focus When scanning arrays with both red and green channels, weak signals or blurry spots are sometimes observed. In this situation, scanner s alignment and focus may require further attention. Typically, alignment problems occur when the mechanical stages fail to correctly return to homing positions, or when the lasers alignment is not optimized. 2) Optimize PMT, laser power, and gain settings 3) Scan the arrays with both red and green channels. 4) Examine the acquired image. The Calibration Slide contains arrays of Cy3 and Cy5 fluorescent dyes in dilution series. Distinctive and well-defined round spots should be observed when laser focus and alignment are in optimal conditions. E. PMT effect Because the scanner s performance may vary at different PMT voltages, PMT settings are important for acquiring adequate images and obtaining reliable data. Using this Scanner Calibration slide, determine the optimal PMT settings for a set of experiments to maximize experimental output. 1) Set the PMT voltage at 100V. 2) Scan the Scanner Calibration Slide with both red and green channels. 3) Record and analyze the image. Calculate the signalto- noise ratio (SNR) for each array column. 4) Increase the PMT setting by 50V, and repeat the process until the voltage setting reaches 1000V. 5) Plot a graph with SNR against the concentrations of Cy3 or Cy5 at each voltage setting. 6) Determine the dynamic range for each voltage setting. 7) Use this graph as a guide for experiment optimization. F. Variations among different scanner units The properties and performance of a microarray scanner unit may be different from another unit. The Scanner Calibration Slide may be used to compare performance between units. P.3

FT-AW390 1) Load a Scanner Calibration Slide on a scanner designated as Unit A. 2) Adjust appropriate settings, scan the arrays, save and analyze the image. 3) On a second scanner, Unit B, scan the arrays at the same settings. Save and analyze the image. 4) Compare the two sets of images and data obtained. Appendix A Array Layout P.4

Appendix B Table 1.1 Fluorophore Density Related products Scanner Validation Slide All-Purpose Scanner Evaluation Slide Ordering information Catalog size quantities and prices may be found at http://www.fluoprobes.com Please inquire for higher quantities (availability, shipment conditions). For any information, please ask : / Interchim; Hotline : +33(0)4 70 03 73 06 Disclaimer : Materials from are sold for research use only, and are not intended for food, drug, household, or cosmetic use. is not liable for any damage resulting from handling or contact with this product. P.5