IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 03, 2015 ISSN (online):

Similar documents
POWER QUALITY ENHANCEMENT IN ARC FURNACE ENVIRONMENT Nupur Laxman Mali,

Unit.2-Voltage Sag. D.Maharajan Ph.D Assistant Professor Department of Electrical and Electronics Engg., SRM University, Chennai-203

OVERVIEW OF SVC AND STATCOM FOR INSTANTANEOUS POWER CONTROL AND POWER FACTOR IMPROVEMENT

Power Quality enhancement of a distribution line with DSTATCOM

Simulation and Comparison of DVR and DSTATCOM Used For Voltage Sag Mitigation at Distribution Side

HARMONIC ELIMINATION IN THREE PHASE SYSTEM BY MEANS OF A SHUNT ACTIVE FILTER

Compensation of Distribution Feeder Loading With Power Factor Correction by Using D-STATCOM

Enhancing Power Quality in Transmission System Using Fc-Tcr

Multi-Pulse Voltage Source Converter Statcom For Voltage Flicker Mitigation

Protection from Voltage Sags and Swells by Using FACTS Controller

A Versatile Control Scheme for UPQC for Power Quality Improvement using fuzzy controller

An Artificial Neural Network Based Real-Time Optimal Reactive Power Flow for Improving Operation Efficiency

Improvement of Power System Distribution Quality Due to Using Dc-Converter Loads and Electric Arc Furnaces. H.A. Khalik, M. A. Aziz, and E. Farouk.

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 08, 2015 ISSN (online):

Power Quality Improvement in Distribution System Using D-STATCOM

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

Power Quality Analysis in Power System with Non Linear Load

Long lasting transients in power filter circuits

A Review on Simulation and Implementation of Thyristor controlled reactor and Shunt Hybrid Power Filter

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

FUZZY CONTROLLED DSTATCOM FOR HARMONIC COMPENSATION

CHAPTER 4 POWER QUALITY AND VAR COMPENSATION IN DISTRIBUTION SYSTEMS

Static Synchronous Compensator (STATCOM) for the improvement of the Electrical System performance with Non Linear load 1

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

Shunt Active Power Filter based on SRF theory and Hysteresis Band Current Controller under different Load conditions

Power Quality Improvement using Shunt Passive Filter

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Modeling and Simulation of SRF and P-Q based Control DSTATCOM

Implementing Re-Active Power Compensation Technique in Long Transmission System (750 Km) By Using Shunt Facts Control Device with Mat Lab Simlink Tool

Design and Simulation of Three Phase Shunt Active Power Filter Using SRF Theory

OPTIMAL DESIGN OF A SINGLE TUNED PASSIVE FILTER TO MITIGATE HARMONICS IN POWER FREQUENCY

Voltage-Current and Harmonic Characteristic Analysis of Different FC-TCR Based SVC

Volume I Issue VI 2012 September-2012 ISSN

Mitigation of voltage disturbances (Sag/Swell) utilizing dynamic voltage restorer (DVR)

Power Quality Improvement using Active shunt Power filter using PI Controller

Harmonic control devices. ECE 528 Understanding Power Quality

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

I. INTRODUCTION IJSRST Volume 3 Issue 2 Print ISSN: Online ISSN: X

Address for Correspondence

Application of Fuzzy Logic Controller in UPFC to Mitigate THD in Power System

Application of SVCs to Satisfy Reactive Power Needs of Power Systems

p. 1 p. 6 p. 22 p. 46 p. 58

Enhancement of Power Quality in Distribution System Using D-Statcom for Different Faults

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

Improvement of Voltage Profile using D- STATCOM Simulation under sag and swell condition

SRI VIDYA COLLEGE OF ENGG AND TECH

Poornima G P. IJECS Volume 3 Issue 6 June, 2014 Page No Page 6453

Investigation of D-Statcom Operation in Electric Distribution System

Voltage Flicker Compensation using STATCOM to Improve Power Quality

Reduction of Voltage Imbalance in a Two Feeder Distribution System Using Iupqc

Design and Simulation of Passive Filter

Application of Tuned Passive Filter for Industrial Six-Pulse Rectifier with R-L Load Viralkumar A. Rana 1 Keyur Rana 2 Atul Talati 3

Performance of DVR & Distribution STATCOM in Power Systems

SIMULATION OF STATCOM FOR VOLTAGE QUALITY IMPROVEMENT IN POWER SYSTEM

Brief Study on TSCS, SSSC, SVC Facts Device

A Thyristor Controlled Three Winding Transformer as a Static Var Compensator

SIMULATION OF DSTATCOM FOR POWER FACTOR IMPROVEMENT

International Journal of Scientific & Engineering Research, Volume 6, Issue 8, August ISSN

Bhavin Gondaliya 1st Head, Electrical Engineering Department Dr. Subhash Technical Campus, Junagadh, Gujarat (India)

IJESR/Nov 2012/ Volume-2/Issue-11/Article No-21/ ISSN International Journal of Engineering & Science Research

Power Quality Improvement of Unified Power Quality Conditioner Using Reference Signal Generation Method

IMPORTANCE OF VSC IN HVDC

Voltage Sag and Mitigation Using Dynamic Voltage Restorer (DVR) System

Power Quality improvement of a three phase four wire system using UPQC

Comparison and Simulation of Open Loop System and Closed Loop System Based UPFC used for Power Quality Improvement

Power Control Scheme of D-Statcom

APPLICATION OF INVERTER BASED SHUNT DEVICE FOR VOLTAGE SAG MITIGATION DUE TO STARTING OF AN INDUCTION MOTOR LOAD

SHUNT ACTIVE POWER FILTER

Performance Analysis of Passive Filter for Harmonics Due to Non-Linear Load in Power System

Mitigation of Voltage Sag and Swell using Distribution Static Synchronous Compensator (DSTATCOM)

Design and Simulation of Fuzzy Logic controller for DSTATCOM In Power System

Improving Passive Filter Compensation Performance With Active Techniques

Power Factor Improvement Using Static VAR Compensator

Reduction In Total Harmonic Distortion Using Active Power Filters

A Voltage Controlled DSTATCOM using Hybrid Renewable Energy DC Link VSI for Power Quality Improvement

Voltage and Current Waveforms Enhancement using Harmonic Filters

INTERLINE UNIFIED POWER QUALITY CONDITIONER: DESIGN AND SIMULATION

Multilevel Inverter Based Statcom For Power System Load Balancing System

D-STATCOM FOR VOLTAGE SAG, VOLTAGE SWELL MITIGATION USING MATLAB SIMULINK

A NOVEL APPROACH TO ENHANCE THE POWER QUALITY USING CMLI BASED CUSTOM POWER DEVICES

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

A Power Control Scheme for UPQC for Power Quality Improvement

Indirect Current Control of LCL Based Shunt Active Power Filter

MLI HYBRID STATCOM WITH WIDE COMPENSATION RANGE AND LOW DC LINK VOLTAGE

Synchronous Reference Frame Control Algorithm Based Four -Leg Inverter DSTATCOM For Power Quality Improvement

ISSN Vol.03,Issue.11, December-2015, Pages:

Fuzzy Logic Based Control of Static Var Compensator

Power Quality Improvement Using Hybrid Power Filter Based On Dual Instantaneous Reactive Power Theory With Hysteresis Current Controller

Three Phase Active Shunt Power Filter with Simple Control in PSIM Simulation

Analysis the Modeling and Control of Integrated STATCOM System to Improve Power System

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

CHAPTER 4 PV-UPQC BASED HARMONICS REDUCTION IN POWER DISTRIBUTION SYSTEMS

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

STATCOM WITH POD CONTROLLER FOR REACTIVE POWER COMPENSATION Vijai Jairaj 1, Vishnu.J 2 and Sreenath.N.R 3

Implementation of D-STACTOM for Improvement of Power Quality in Radial Distribution System

A Review on Power Quality Improvement in Distribution System using UPQC

Design and Simulation of DVR Used For Voltage Sag Mitigation at Distribution Side

Analysis, Modeling and Simulation of Dynamic Voltage Restorer (DVR)for Compensation of Voltage for sag-swell Disturbances

Comparative Analysis of Multiple-pulse VSC-Based STATCOM s for Voltage-Dip Mitigation

A Review on Improvement of Power Quality using D-STATCOM

Transcription:

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 03, 2015 ISSN (online): 2321-0613 Mitigating the Harmonic Distortion in Power System using SVC With AI Technique Mr. Sanjay Prajapati 1 Mr. Vishal Gandhi 2 Mr. Rishikesh Agrawal 3 Mitul Vekaria 4 1,2,3,4 Department of Electrical Engineering Abstract The reactive power compensation in a power distribution network plays a vital role in improving voltage and power system stability. Flexible AC transmission system (FACTS) devices like Static Var Compensators (SVCs) are used to control reactive power generation or absorption in long transmission line. However, these SVCs will introduce harmonic current in to the system due to the operation of thyristor controlled reactors (TCR). This paper proposes minimize harmonic injected using svc & passive filter combination and modified AI technique approach to minimize the harmonics injected into the systems with the operation of TCR-TSC type SVC used in conjunction with fast-changing loads. Optimum triggering delay angles used to trigger thyristors in TCR are calculated using the proposed to achieve better, smooth and adaptive control of reactive power as well as harmonics. And define which system is best for minimum injected harmonic in power system. Key words: Introduction, Harmonics, Passive filter,, Static Var Compensator (SVC), AI techniques (ANN), Simulation and Results, Experimental Setup and Result I. INTRODUCTION Harmonics and reactive power regulation and guidelines are upcoming issues and increasingly being adopted in distributed power system and industries. Vital use of power electronic appliances has made power management smart, flexible and efficient. But side by side they are leading to power pollution due to injection of current and voltage harmonics. Harmonic pollution creates problems in the integrated power systems. Thyristor-controlled static var compensators (SVCs) are the commonly used FACTS device in modern power-supply systems for compensating loads due to low cost and simple control strategy. An SVC can consist of a thyristor controlled reactor (TCR) and a thyristor switch capacitor (TSC) and compensates loads through the generation or absorption of reactive power [3]. A continuous range of reactive power consumption is obtained by the operation of TCRs at appropriate conduction angles. However this operation results in the injection of harmonic currents into the power supply. There are various techniques available in the literature to reduce the harmonics injected by TCR into the power system. Simplest method is to use appropriate harmonic filters with the TCR or introduce some technique to minimize harmonic generation internally. II. HARMONIC Harmonic distortion is not new and it constitutes at present one of the main concerns for engineers in the several stages of energy utilization within the power industry. In the first electric power systems, harmonic distortion was mainly caused by saturation of transformers, industrial arc furnaces, and other arc devices like large electric welders. The major concern was the effect that harmonic distortion could have on electric machines, telephone interference, and increased risk of faults from overvoltage conditions developed on power factor correction capacitors. In the power system study, harmonics is more important. Here some problems due to harmonic in power systems are: Electrical equipments are operate uncertainly at same time of day Equipment damage at thunderstorm occur Circuit breakers are operate without overloading condition Frequency basis, electronic components are fail Automated system does not work properly Harmonics in voltage or current waveforms can then be conceived as perfectly sinusoidal components of frequencies multiple of the fundamental frequency: Fn= (h) x (fundamental frequency) Where n is integer For example: third harmonic is a harmonic component Fn= (5) X (50) =250 Fig.1: Sinusoidal 50-Hz waveform and harmonics.[9] Figure 1 shows an ideal 50-Hz waveform with a peak value of around 100 A, which can be taken as one per unit. Likewise, it also portrays waveforms of amplitudes (1/7), (1/5), and (1/3) per unit and frequencies seven, five, and three times the fundamental frequency, respectively. This behavior showing harmonic components of decreasing amplitude often following an inverse law with harmonic order is typical in power systems [7]. These fundamental 3rd 5th and 7th harmonic equations are Im = Im sin(ωt) Where Im is the peak RMS value of harmonic current n. III. PASSIVE FILTER Passive filters are very much helpful for mitigation of harmonic component and used traditionally. Passive filters are used for the mitigation of harmonic in the electrical All rights reserved by www.ijsrd.com 428

society for last 3 decades and there is a continuous development has been reported in this technique for the better use of filter and convert the filter more useful to achieve the optimum approach to utilization with reduced rating and cost [4].The performance of passive filter depends mainly on the system source impedance.fig.2 Mitigating the Harmonic Distortion in Power System using SVC With AI Technique Fig. 2: Passive filter There are various issues in the design of a passive filter for its proper functioning in harmonic reduction. The key issues are mentioned here: A. Minimizing harmonic source current The prime objective of the filter design is to minimize the harmonic current in ac mains. This is ensured by minimizing the filter impedance at the harmonic frequencies so that the harmonic filter acts as a sink for the harmonic currents. B. Minimizing fundamental current in passive filter To ensure that the installation of passive filter does not cause the system loading, the fundamental current in the passive filter is minimized by the maximizing the passive filter impedance at the fundamental frequency. C. Environment and ageing effect The capacitors with metalized film construction lose capacitance as they age. Similarly the manufacturer tolerance of the harmonic filter reactor may result in tuned frequency higher than the nominal. An IEEE Standard 1531[4] recommends that the passive filters are tuned at 6% below the rated frequency so that it will exhibit acceptable tuning at the end of its 20 year life. The passive shunt filter consists of first order series tuned low pass filters for 5th and 7th order harmonics. For the series tuned low pass filters, the impedance is given by: Fig. 3: Low pass Filter and High pass Filter Xc = Where Qsh is the reactive power provided by the passive filter, h is the harmonic order of the passive filter; XL is the reactance of inductor. Xc is the reactance of the capacitor at fundamental frequency. The reactive power requirement may be initially assumed around 25% of the rating of the load. It may be equally divided among different filter branches. The values of series tuned elements may be calculated from eqn. (3.4). The quality factor for low pass filter (defined as QF =XL/R), is consider as 30 in this work to calculate the value of the resistive element. The resonant frequency for the hth harmonic is given as: Quality factor can be defined as The values of filter components can be calculated from above equations. The design of the passive shunt filter is carried out as per the reactive power requirements. This filter is designed to compensate the requirements of reactive power of the system. IV. STATIC VAR COMPENSATOR The Static Var Compensator (SVC), a first generation FACTS controller is taken up for study. It is a variable impedance device where the current through a reactor is controlled using back to back connected thyristor valves. The application of SVC was initially for load compensation of fast changing loads such as steel mills and arc furnaces. Here the objective is to provide dynamic power factor improvement and also balance the currents on the source side whenever required. The control system consists of followings: (1) A measurement system for measuring the positivesequence voltage to be controlled. (2) A voltage regulator that uses the voltage error (difference between the measured voltage Vm and the reference voltage Vref) to determine the SVC susceptance B needed to keep the system voltage constant. (3) A distribution unit that determines the TSCs (and eventually TSRs) that must be switched in and out, and computes the firing angle α of TCRs (4) A synchronizing system using a phase-locked loop (PLL) synchronized on the secondary voltages and a pulse generator that send appropriate pulses to the thyristors All rights reserved by www.ijsrd.com 429

Mitigating the Harmonic Distortion in Power System using SVC With AI Technique The block diagram of a general TSC TCR type of SVC control system. VI. SIMULATION AND RESULT A. Case Study-I (without svc): B. Simulation of Case Study-I (With Svc): Fig. 4: A general schematic diagram of an SVC control system[9] V. ANN APPROACH The relationships between the inputs to the controller, i.e., phase wise active and reactive power demands and the outputs, i.e., the firing angles and the TSC step size are quite complex and it is difficult for a single neural network to approximate such a complex relationship. The proposed algorithm can be used for real time control of SVCs which are used to compensate unbalanced fluctuating loads. The neural network is trained to approximate the function of the fuzzy logic based SVC control algorithm in order to reduce the computational time. The structure of ANN controller used is shown in Fig.4 It was observed that the dependency of the outputs on the real power demands is minimal. It reflects only in calculation of the load bus phase voltages. Small change in load bus voltages doesn't much affect on the amount of reactive power absorbed or supplied by the TCR and TSC respectively. In order to reduce the complexity of neural network only reactive power demands are used as inputs to the controller. The neural network controller used contains a three layer feed forward neural network each of which takes load reactive power demands in each of the three phases as inputs. Each layer generates the optimum triggering delay angle al, a2 or a3 corresponding to the delta reactances Xab,Xbc and Xca respectively. C. SVC Model D. A.C Voltage response % THD Without SVC & FILTER Fig. 5: Schematic diagram of the ANN controller All rights reserved by www.ijsrd.com 430

Mitigating the Harmonic Distortion in Power System using SVC With AI Technique With SVC & FILTER With SVC & ANN MATLAB SIMULINK MODEL VII. RESULT VOLTAGE THD% CURRENT THD% Without SVC & Filter 17.94 4.44 With SVC & Filter 6.90 3.62 With SVC & ANN 1.07 1.05 With SVC & ANN E. A.C Current Response % THD Without SVC & FILTER With SVC & FILTER VIII. CONCLUSION After this simulation concludes that a thyristor controlled Static Var Compensators (SVCs) are popularly used in modern power supply systems for compensating loads. The operation of Thyristor Controlled Reactors at appropriate conduction angles can be used advantageously to meet the phase-wise unbalanced and varying load reactive power demand in a system. However, such an operation pollutes the power supply in another form by introducing harmonic currents into the power supply system. In this case minimum injected harmonics using SVC & Filter combination. AND Minimum injected harmonic using SVC with AI Technique Analysis of simulation results. Comparison of all the simulation results and define that SVC with AI Technique method is better compare that svc with filter. REFERENCES [1] George J. Wakileh, Power system harmonics, fundamentals, analysis and filter design, New York, Springer-Verlog Berlin Heidelberg, 2001, pp 81-103. [2] IEEE recommended practices & requirements for harmonic control in electrical power systems, IEEE 519 standard, 1993. [3] Arindam Ghosh and Gerard Ledwich, Power quality enhancement using custom power devices, London, Kluwer Academic Publishers, 2002, pp 55-111. [4] B. Singh, K. A. Haddad and Ambrish Chandra, "A review of active filters for power quality improvement", IEEE trans. Industrial Electronics, Vol. 46, No.5, Oct.99. [5] A.Elnady and Magdy M.A.Salama,"Unified approach for mitigating voltage sag and voltage All rights reserved by www.ijsrd.com 431

flicker using the DSTATCOM", IEEE trans. Power Delivery, Vol.20, No.2, April 2005. [6] D.Thukaram., A. Lomi and S Chirarttananon, "Minimization of harmonics under three phase unbalanced operation of static VAR compensators", Proceedings of the 12th International Conference on Power Quality, Chicago, U.S.A., 1999. [7] Athula Rajapakse, Anawat Puangpairoj, Surapong Chirarattananon, and D.Thukaram, "Harmonic Minimizing Neural Network SVC Controller for Compensating Unbalanced Fluctuating loads", 10th International Conference on Harmonics & quality of power 2002, vol.2, pp 403-408, Oct. 2002. Mitigating the Harmonic Distortion in Power System using SVC With AI Technique All rights reserved by www.ijsrd.com 432