Installation, Operation and Maintenance Manual

Similar documents
IOM. Model 1050 Strain Gage Transmitter Installation & Operation Manual. (Cage Code #1MU21)

Installation, Operation and Maintenance Manual

WIRING. Model FC Mass Flow Computer Wiring Diagrams

WIRING. Model BC Flow Totalizer, Ratemeter and Batch Controller Wiring Diagrams

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS

SC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585)

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

Model TL Linearized Platinum Resistance Thermometer Temperature Transmitter Instruction Manual

Installation, Operation and Maintenance Manual

HUMITRAN-RHT & RH RELATIVE HUMIDITY/TEMPERATURE TRANSMITTER RELATIVE HUMIDITY TRANSMITTER

SC-FI Series Frequency to Current Signal Conditioner

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

MODEL AT-10 ANALOG TRANSMITTER

KING-GAGE ES2. Installation and Operation Instructions Manual. Electronic Liquid Level Transmitter. ESR Serial No. Versions and Slimline Versions

Service Instructions. The Conductor Controls. Conductor DC15-A, Enclosed Unit CH15-A, Open Chasis Unit

User Manual. ProRF Encoder Transmitter & Receiver

Series APD4059. For Load Cells/Pressure Transducer Transmitters. Field Rangeable, with Calibration Resistor. Standard Features.

ISOLATED 4-20 ma TRANSMITTERS

AD-8100 & AD-8200 Servo Amplifiers

C 2030 חפר מיכשור ומערכות בע"מ טכנולוגיות לטיפול במים ושפכים מיכשור אנליטי למדידה ובקרת תהליכים OPERATOR'S MANUAL. 2- Wire E.C transmitter Din Rail

Model 1791 VHF Radio User's Manual

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

MFJ-834 RF Ammeter. Introduction. Uses

CEC VIBRATION TRANSMITTER

Non-Submersible Industrial Pressure Transducer

User s Guide FLSC-45/45B. Paddlewheel Signal Conditioner. Shop online at omega.com

PARALLEL ELEMENT ANTENNA MODEL PEA-30

HI 2204LT Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL

IB6 Series Solid-State Isolation Relay

ARD154. DIN rail mountable amplifier for strain gage sensors. User s guide. User s guide ARD CONNECTING 4-WIRE SENSORS

TRANSDUCER IN-LINE AMPLIFIER

Explosion Proof Page/Talk Paging Amplifier

Instruction Manual TABLE OF CONTENTS 1 PRINCIPLE OF OPERATION Limitations INSTALLATION Mains connection...

Detcon Model FP Transmitter Test Fixture Operators Instruction Manual June 17, 2008 * Document 3389 * Revision 1.1

DRG-SC Series Signal Conditioners

Load Cell Accessories and Services

MODEL , MODEL 310SAO, AND MODEL 310-ALT

MODEL UBP-10 UNIVERSAL IN-LINE TRANSDUCER AMPLIFIER BI-POLAR SUPPLY, 0-10 VOLT OUTPUT

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL

HLC-1000 High-limit Humidity Control

3 CHANNEL LOAD CELL SIGNAL CONDITIONER. Owner's Manual

INSTRUCTION MANUAL CLEVELAND-KIDDER TENSION INDICATOR SERIES AO REVISION

MODEL 174 LIQUID LEVEL TRANSMITTER

Instruction Manual. HB Series Mini Level Sensor

Series GLET Accessory for dataloggers series GL in modular enclosure

The Harvard Research Carrier Signal Conditioner User s Manual

CAP ANALOG 410 INSTALLATION & OPERATION MANUAL

Installation & Operation Manual

Two-Wire Programmable Transmitter for:

TECHNICAL MANUAL. SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

Why Modern Servicing Requires Complete Waveform & Circuit Analyzing!

Model A. DIN Rail Strain Gage Conditioner. Installation and Operating Manual

INSTALLATION AND OPERATION MANUAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARD (Part No. 9668)

+GF+ SIGNET Temperature Transmitter Instructions

This Errata Sheet contains corrections or changes made after the publication of this manual.

Effective: June, 2000 EX-1821 Satellite Display Unit Receiver Installation Manual Models: 4643-*-* 4644-*-9 Since 1937

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

OP5000 Signal Conditioning & I/O Products for RT-LAB Engineering Simulators OP5511 High-current and high-voltage input conditioning module

1) What meter do I need in this application?

Instruction Manual. SSQ-2F Controller Board. For the. v1.41 For Rife Plasma Tube Systems. Manual v by Ralph Hartwell Spectrotek Services

670K9 SORtrax Level Transmitter

QRS14 User s Guide. MEMS GYROSCOPE Model QRS14. Systron Donner Inertial Sales and Customer Service. Phone: Fax:

TRANSDUCER IN-LINE AMPLIFIER

Current Probes. User Manual

Technical Service Bulletin DCX AGC Setup Procedure for MODAP Exciters

UNIVERSAL INPUT RESISTANCE OUTPUT

ELECTRIC FIELD PROBE ANTENNA MODEL PEF-10A. 20 Hz 1 MHz

Technical Service Bulletin DCX AGC Setup Procedure for ADAPT IV Exciters

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual

The Rosemount 848T Wireless Temperature Transmitter

OPERATING INSTRUCTIONS

MOXTEK. 50kV 10 Watt MAGNUM X-ray Source. X-ray Sources. Contents

INSTALLATION AND OPERATING MANUAL

Glass Electrode Meter

LINEAR LINK QUICK REFERENCE MANUAL Basic Installation, Programming & Troubleshooting

Worldwide Manufacturer of Gas Detection Solutions. Transmitter EC 23. Operation Manual

Band-Master ATS Nano Pneumatic Banding Tool Operating Instructions

Installation Instructions

BENCHMARK MEDIA SYSTEMS, INC.

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

CSG110 Strain Gauge Universal Amplifier

INSTRUCTION MANUAL MODEL 2779 SUBCARRIER MODULATOR

Telemetrie-Messtechnik Schnorrenberg

INSTALLATION & OPERATION MANUAL

This Errata Sheet contains corrections or changes made after the publication of this manual.

Model 1202B Power Measurement System

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

User Manual CTP4/8/16

User s Guide TX94A. Ultra-Miniature Temperature Transmitters. Shop online at omega.com

Electro-Mech Scoreboard Co. Product Guide

Operating Manual. Model Channel. DC Signal Conditioner Amplifier

MABEL, PiTone and Allstar for the Yaesu Fusion DR-1X Repeater

AUTO CAL II PO Box Sta Safety Road Houma, LA Tel # Fax #

CTP16-Rotate. KMT - Kraus Messtechnik GmbH

CS105 BAROMETRIC PRESSURE SENSOR

TECHNICAL MANUAL. SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100

Transcription:

TM M723 Rev. C Model 1050 Strain Gage Transmitter Installation, Operation and Maintenance Manual

Table of Contents General... 1 Installation... 1 Specifications... 1 Wiring... 2 Setup and Operation... 4 Dimensions... 6

Installation, Operation & Maintenance GENERAL The Model 1050 is a signal transmitter for use with the Mark V and Mark VII strain gage target flowmeters. When supplied with a DC voltage, the Model 1050 provides an output signal that is proportional to the flow rate through the Mark V. The signal from the meter is converted to either DC voltage or current and frequency output signals. INSTALLATION Normally, the Model 1050 will arrive mounted on a Mark V strain gage target meter and will be wired to the strain gage bridge. (The only exception should be for remote mounting due to accessibility or unusual environmental conditions.) After mounting the target meter, field wiring to the readout instrument must be added. To complete the installation, the meter calibration should be checked. Note: In high temperature applications such as steam, do not insulate the Model 1050. By not insulating, the heat will be allowed to dissipate and keep the internal electronics cooler. Also, the unit will be more serviceable. Note: Signal conditioner boards are assigned to a particular serial number and should remain as a set; calibration error may occur if boards are interchanged with those from another serial number. SPECIFICATIONS Features: Low flow cut off; flow inputs below the usable portion of the input range will be suppressed to zero. Input: Strain gage bridge Output: Analog: 4-20 ma (std.) 0-20 ma 1-5 VDC 0-10 VDC** Digital: 0-1000 Hz (std.) Load impedance: 600ý max. for current output at 24 VDC* Power: 12-36 VDC standard; 100 ma at 12 VDC; 60 ma at 24 VDC (plus 4-20 ma, if used) Temperature: 32-140 F (0-60 C) Accuracy: ±0.1% of full scale Repeatability: ±0.25% point Electrical connections: Through 3/4" NPT hole; four position terminal block for input power and two output signals Wiring lengths: Up to 75' for remote mounting from target meter to Model 1050; up to 5000' from 1050 to instrumentation 1

Enclosure: Mounted in explosionproof watertight housing (rated Class I, Groups B, C, & D; Class II, Groups E, F, & G; Class III; NEMA 4) Weight: 4 lbs. Warranty: Standard one year *The Model 1050 has a maximum load of 500ý if the supply voltage is at least 14 volts. But if a supply voltage of less than 14 volts is used, the maximum load drops (for example, to 400ý at 12 volts). The voltage should be measured at the Model 1050, not at the power supply itself. Make sure that the field wiring is of low enough resistance to meet voltage requirement. **With factory modification. WIRING Caution: This is a three (3) wire device. Incorrect wiring of this device may cause permanent damage. Disconnect power before removing or inserting PC boards. Failure to do so can damage the PC boards. Three wires are needed between the Model 1050 and the receiving instrument. The wires are ground (circuit common), supply voltage (12 to 36 volts), and the signal output. The signal output can be a 4-20 ma and/or a 0-1000 Hz signal. They exist on separate output terminals, and both signals may be used if necessary. A fourth wire is required if both signals are used. See Figure 1 for possible hookup arrangements. Care must be taken to avoid exposing wiring to any source of electrical interference. Methods of doing this include installation in conduit, use of shielded wiring, and the routing of wiring away from known noise sources such as welders, radio transmitters, etc. Shielded cable should be grounded at one end only. We recommend grounding at the signal source. In a high radio noise environment, conduit may be needed to get maximum isolation from RF noise. Keep all wiring in metal conduit and metal boxes wherever possible. Any breaks should be as far from the meter and RF sources as possible. Care should be taken so that wires do not interfere with box cover replacement. 2

Figure 1. Wiring Diagram General Hookup *Connections for optional integral RTD Temperature Sensor Models 1030, 1530, and 3030 Vin Do not connect the 24 VDC out terminal of the Model 1030/1530/3030 to the Model 1050 if the 1050 is powered from another source. For connections from the flow meter to the Model 1050, see general hookup wiring diagram. For other connections to the Model 1030/1530/3030, refer to the respective manual. Remote Mounting 75 of 18 gauge wire 3

SETUP AND OPERATION This procedure must be performed after the Mark V strain gage target meter and the Model 1050 have been installed. A digital volt meter (DVM) is required. Caution: Disconnect power before removing or inserting PC boards. The wiring terminal connector may be removed and replaced for easier accessibility. Do not wire with power on. Always connect the ground wire first and disconnect it last. Be sure the meter is properly installed and in its final operating position. There must be no flow while calibration is in progress. All of the potentiometers, test points, and header switches referred to in the following instructions are on the top board unless otherwise noted. See Figure 2 to locate their exact positions. 1. Hook up the DVM between circuit common (GND) and TP3. 2. Be sure SW2 is in the F (fast) position. Note original position. 3. Be sure SW1 is set in the OP position. 4. Adjust the pot RP2 (labeled zero) to get 0.000 volts on the DVM. 5. Move the DVM lead from TP3 to TP5. 6. Move SW1 to the CAL position. 7. Adjust pot RP3 (labeled CAL) to the value shown on the calibration record under TP5 (0-10V) VDC. 8. Repeat steps 2-5 until no further change is noted. 9. Return SW1 to the OP position. 10. Return SW2 to its original position. Note: Steps 1-3 must be performed when the flowmeter is installed, removed and reinstalled, or changed in position in any way. The rest of the procedure need only be done as a periodic check on the meter calibration. Note: SW2 selects either a fast or slow response to any change in input. Because of possible noise pickup, it is recommended that SW2 be left in the slow (SL) position. It can be moved to the fast (F) position if a quicker response to changes in the flow rate is required. Cut-off is a drop-out adjustment point that makes the transmitter output zero below the accurate range of the meter. The cut-off is factory set to its optimal value. It is set by adjusting RP1 while reading the voltage on TP1. Adjusting the cut-off is strongly discouraged. Under no condition should it be set lower than 0.4 VDC. Consult factory. 4

Figure 2. Jumper and potentiometer locations Power Board Assembly Part # 60122G228 Signal Board Assembly Part # 60122G229 Adjustment Board Assembly Part # 60122G227 5

DIMENSIONS 150 Venture Boulevard Spartanburg, SC 29306 Phone: (800) 778-9251, (864) 574-3327 Fax: (864) 574-8063 Repair Service: (800) 778-9249 Internet: www.aaliant.com E-mail: sales@aaliant.com A Product Line M723 Rev. C 11/02