for a manual for steel detailers, engineers & fabricators, containing working drawings & details for hot-dip galvanized structures

Similar documents
Suggested Specification for Preparing Hot-Dip Galvanized Steel Surfaces for Painting Revised February 2002

(50 FT FT) MICHIGAN DEPARTMENT OF TRANSPORTATION 10-0" 7-6" 8-0" 6-0" Truss Depth. 3" sheets 5 & 6 of 10) DEPARTMENT DIRECTOR. Kirk T.

TYPE J (20 FT - 40 FT) MICHIGAN DEPARTMENT OF TRANSPORTATION 10-0" 7-6" NOTE: sheet 5 & 6 of 10) DEPARTMENT DIRECTOR. Kirk T.

Requirement for Holes - Holes for Hanging

Design Guide for Hot Dip Galvanizing best practice for venting and draining

SECTION STRUCTURAL STEEL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION STRUCTURAL STEEL. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION METAL FABRICATIONS

Runcorn: A Project First for Europe

Hot Dip Galvanizing by Perry Metal Protection

STANDARD SPECIFICATION FOR STEEL FRAMING FOR RAILROAD SHELTERS

STRUCTURAL STEEL AND ALUMINUM PART 1 - GENERAL 1.01 SCOPE:

Bol FEATURES: SPECIFICATIONS: 8' 24' Round Tapered and Straight Wood Poles STRUCTURA INC. FIXTURE TYPE: PROJECT NAME:

Product Guide Specification

STEEL PIPE GUIDERAIL 01/01/

SECTION CABLE TRAYS

6o ft (18.3 m) Southwest Windpower, Inc West Route 66 Flagstaff, Arizona USA Phone: Fax:

Ordering example: WSK-600 / B x H x L = 155 mm. M8 hexagon head screw, fixed by a locknut. Threaded bolt

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

Architecturally Exposed Structural Steelwork (AESS) Sample Specification (for Engineers)

1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards.

SECTION BULLET- RESISTANT DOORS

Fig. 9 Different weld positions. There are five basic types of common joints. They are

CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST

orthwest Corrosion Engineering

SECTION CABLE TRAYS FOR ELECTRONIC SAFETY AND SECURITY

1.1 RELATED DOCUMENTS

Two basic types of single

Basic Welding Symbols and Their Location Significance

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

SECTION 520 STEEL STRUCTURES GENERAL Gray iron castings shall conform with the requirements of AASHTO M 105, Class 30.

D. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC

Manufacturing Process:

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

ALUMINUM PIPE GUIDERAIL 01/01/

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

Architecturally Exposed Structural Steelwork (AESS) Code of Practice (for Fabricators)

SECTION CONCRETE REINFORCEMENT FOR STEAM UTILITY DISTRIBUTION

Skewed connections result when members frame to each

Design and Construction Standards SECTION ATHLETIC LOCKERS

AESS Documents prepared by CISC ad hoc committee

Barofor Round System (polyester coated) Panels, Posts, Accessories

Copyright Notice. HCL Technologies Ltd. All rights reserved. A DEFINITIVE GUIDE TO DESIGN FOR MANUFACTURING SUCCESS

SECTION HOLLOW METAL DOORS AND FRAMES

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

Delmec Engineering Limited

UP133 CRAWL & TODDLE (STANDARD) NATURAL COATED DECK COATED RAMP FRONT WALL BACK WALL DESCRIPTION COATED STEPS 90 ANGLE BRACKET LEFT WALL RIGHT WALL CL

Fabricated Structural Steelwork. Section 8

AASHTO/NSBA Steel Bridge Collaboration G Design Drawing Presentation Guidelines. AASHTO/NSBA Steel Bridge Collaboration

STEEL REPAIR PROCEDURES OPERATIONS MANUAL

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

STORAGE SHED. Storage Shed SOUTHERN FOREST PRODUCTS ASSOCIATION SOUTHEASTERN LUMBER MANUFACTURERS ASSOCIATION

JVI Vector Connector

Ash Brook Golf Course Scotch Plains, New Jersey

To give parts and instructions to replace the wing root canted rib upper cap with a new strengthened replacement cap.

GUIDELINE SPECIFICATIONS

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

EMMEGI ARCHITECTURAL FENCING MASTER SPECIFICATION SECTION METAL FENCING, GATES & RAILING SYSTEM PART 1 GENERAL

INSTRUMENT MOUNTING STANDS PRODUCT CATALOG Continuous Tray Support System for Instrumentation and Controls

TECHNICAL CORRECTION October Process Industry Practices Structural. PIP STF05121 Fabrication and Installation of Anchor Bolts

GLOSSARY OF TERMS SECTION 8

STRUCTURAL BRACKETS CATALOGUE

Structural Bolting. Notice the Grade 5 has a much smaller head configuration and a shorter shank then the grade A325 structural bolt.

A E D X E X C A C B A L B E L E T R T A R Y

Unlimited work preparation of beams & bars

UP139 CRUISE-A-LONG (STANDARD) NATURAL COATED DECK COATED RAMP DESCRIPTION SQUIRREL PANEL BACK WALL CLEAR BUBBLE CRUISE RAIL SQUARE SPIRAL WHEEL 90 AN

The General Principles of Detailed Design at Ruukki Construction Ltd. Julia Piiroinen

2016 AASHTO BRIDGE COMMITTEE AGENDA ITEM: 24 (REVISION 1) SUBJECT: LRFD Bridge Design Specifications: Section 6, Various Articles (2)

APPENDIX FENCE GENERAL NOTES

712 - STRUCTURAL STEEL CONSTRUCTION SECTION 712 STRUCTURAL STEEL CONSTRUCTION

Toll-Free

MISCELLANEOUS SIGN CONNECTION DETAILS TYPICAL ROUTE MARKER ASSEMBLIES SIGN TO POST MICHIGAN DEPARTMENT OF TRANSPORTATION

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, EDITION 2015

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

AUXILIARY FRAMING AND ACCESSORIES

MEM12007D Marking off/out structural fabrications and shapes

Engineering Services Program

Versai Evolution of Versatile Fencing

Khathij Industrial Fasteners

Exclusive Cantilever Gates

Credit Value 7 QCF Level 2 GLH 50. Learner pack

Engineering Test Report

ZIP System Roof Sheathing INSTALLATION MANUAL A REVOLUTION IN ROOFING

FUEL GAS PIPING SECTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section.

NOTES: 4" OVERHANG MAX. (TYP) DETAIL N (SHEET 13)

C. HMMA 863: Guide Specifications for Detention Security Hollow Metal Doors and Frames

Pre-Galv vs Post-Galv Specifications for Cable Containment Products

1. ANSI/ASME Standard B , Square and Hex Bolts and Screws, Inch Series

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions

PIP STF05121 Anchor Fabrication and Installation Into Concrete

SMAW LESSON #1: Initiating and maintaining an arc using the scratch start method

GENERAL ELEVATION SECTION A-A

GENERAL ISOMETRIC LAYOUT

Installation Instructions for Standard Lap and Self-Aligning Lap Siding

ROUND STEEL POLE STRAIGHT

Advance Steel. Tutorial

Panel fencing system 2D 6/5/6

Roof-Top Applications

No No No

Transcription:

for a manual for steel detailers, engineers & fabricators, containing working drawings & details for hot-dip galvanized structures

l b Ta f o e s t en t n Co Recommended Details for Hot-Dip Galvanized Structures # Title 1 Framed Beam connections 2 Combination Section - Flange & Channel 3 Combination Section - Two channels 4 Combination Section - Wide Flange & Channel 5 Combination Section - Channel & angle 6 Combination Section - Channel & Angle 7 Gusseted Connection - Welded 8 Gusseted Connection - bolted 9 Double Angles 10 moment splice at ridge (Field Bolted) 11 Simple Column base (base plate shop welded) 12 Simple Column base (base plate field welded) 13 moment resisting column base (base plate field welded) 14 moment resisting column base (base plate shop welded) 15 Web Stiffener 16 column splices - bolted 17 butt plate coumn splice - bolted 18 butt plate coumn splice - welded 19 Bracket plate 20 box truss 2012 American Galvanizers Association. The material provided herein has been developed to provide accurate and authoritative information about after-fabrication hot-dip galvanized steel. This material provides general information only and is not intended as a substitute for competent professional examination and verification as to suitability and applicability. The information provided herein is not intended as a representation or warranty on the part of the AGA. Anyone making use of this information assumes all liability arising from such use.

1. The contents of this publication are the result of a widespread survey conducted among AGA members. Some may prefer different details, based upon their own experiences, to achieve desired results in the galvanized product. 2. Certain details call for welding after galvanizing. More information concerning welding and subsequent touch-up of galvanized steel is available in the American Galvanizers Association s (AGA) Welding & Hot-Dip Galvanizing publication. If possible, steelwork should be designed to be bolted rather than welded after galvanizing. 3. Welding symbols are those defined in AWS A2.4-2012 Welding & hot-dip galvaning publication. Shop welding symbols are usually accompanied by a notation intermittent or by Cont. meaning continuous. in the absence of any other notation, it is assumed the weld will be continuous (AWS A3.0-2010 includes standard welding terms and definitions.) 4. Class I Details are those consisting of parts joined together by a full seal weld, or parts which are bolted together after galvanizing. This class represents the highest degree of corrosion protection attainable, but does require more fabrication cost. 5. Class II Details are those consisting of overlapping parts joined together by seal welding and which have an overlap area large enough to need venting in accordance with the appropriate guidelines of Note 7. A very high degree of corrosion protection is available with these details, although not quite equal to Class I. More work is required than is customary for normal fabrication standards. It should be noted Class II can be upgraded to Class I by plugging vents after galvanizing. lass III 6. C Details do not include seal welding and may require only slightly more fabrication effort than normally employed on a non-galvanized structure. Class III details enable the galvanizing to provide a degree of corrosion protection that meets or exceeds the protection provided by most industrial coatings to identical details. 7. Pin holes may exist in seal welds around overlaps in Class I details. Liquids from galvanizer s cleaning baths may pass through the pin hole and enter the overlap area, where it will remain as it is immersed in the molten zinc. Possibility of explosion exists as the trapped liquid vaporizes and expands at a temperature of approximately 850 F. Danger of explosion is more acute for larger overlapped areas. It is recommended the fabricator provide a vent in one of the overlapping plates according to the following guidelines. Location of the vents need not be exact, provided they are in the same general location as shown on the drawing. Arrangements may be made for installation of vent holes by the galvanizer. 2 Overlapped Area (IN ) Venting Requirements < 16 None > 16 and < 64 when steel is < 1/2 thick One 3/8 Dia. hole, or leave 1 of weld undone adjacent to same location >16 and < 64 when steel is > 1/2 thick None > 64 and < 400 One 1/2 diameter hole, or leave 2 of weld undone adjacent to same location Each increment of 400 One 3/4 diamenter hole, or leave 4 of weld undone adjacent to same location 8. Emissions from the unsealed overlaps of class II and Class III details may cause a stain on the surface of the coating. This applies whether the coating is paint or galvanizing. The stain is usually superficial and will disappear in time as the galvanizing weathers. 9. m oisture steaming from unsealed overlaps in class II and Class III joints may result in slight bare spots along the line of the exhaust. If touch-up of these is required it may be accomplished by any of the materials described in ASTM A780 Standard practice for repair of hot-dip galvanized coatings. 10. After galvanizing, finished ends of column sections shall be ground smooth to remove projections.

Framed Beam connection 1

Caution: This section is subject to warpage and may require straightening after galvanizing. To minimize warpage, refer to the recommendations of the AGA and ASTM A384. american Combination Section Flange & Channel 2

Combination Section two channels Caution: This section is subject to warpage and may require straightening after galvanizing. To minimize warpage, refer to the recommendations of the AGA and ASTM A384. 3

Caution: This section is subject to warpage and may require straightening after galvanizing. To minimize warpage, refer to the recommendations of the AGA and ASTM A384. american Combination Section Wide Flange & Channel 4

Caution: This section is subject to warpage and may require straightening after galvanizing. To minimize warpage, refer to the recommendations of the AGA and ASTM A384. american Combination Section Channel & Angle 5

Caution: This section is subject to warpage and may require straightening after galvanizing. To minimize warpage, refer to the recommendations of the AGA and ASTM A384. american Combination Section Channel & Angle 6

Gusseted connection welded 7

gusseted connection bolted 8

Double Angles 9

moment splice at ridge (field bolted) 10

Simple Column base (base PLate shop welded) 11

Simple Column base (base PLate field welded) 12

moment resisting Column base (base PLate field welded) 13

moment resisting column base (base plate shop welded) 14

Note for both Classes: Bevel weld may be used instead of fillet weld, at designers option. american Web Stiffener 15

L american Column splices - Bolted 16

Butt plate column splice bolted 18

butt plate column splice welded 19

bracket plate 17

box truss 20

American Galvanizers Association 6881 S Holly Circle Suite, 108 Centennial, CO 80112 www.galvanizeit.org 720.554.0900 aga@galvanizeit.org