FLOWPET-NX (Oil Service Mechanical Register)

Similar documents
FLOWPET-EG. Description 1 Accumulated total flow (8-digit) 2 Instantaneous flowrate, L/h (mode:b1) and L/min (mode:b2) Selectable with

Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG

Inexpensive PD for Boiler Feed Water and Oil FLOWPET-5G

OVAL FLOWMETER. Meter Size: 52, 53, 55, 56, 57 Double Case Construction with Powerful Magnetic Coupling ( ) Magnetic coupling Outer Housing

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit

SLIDE VANE FLOW METER SPECIFICATIONS

New Single Straight Tube Type OVAL Coriolis Mass Flowmeter. MK Transmitter : ST9101, ST9801. See general performance table (page 2).

1) What meter do I need in this application?

EGC100W MAGMAX. Converter for Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

Size : Connection End : Min Temperature : Max Temperature : Materials : Cast iron body

High Performance Coriolis Flowmeters. Transmitter : MT9411. SUS316L, SUS316L +Alloy C, Alloy C Housing

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Design and applications

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

WATERFLUX 3070 Technical Datasheet

Straight-Tube Coriolis Flowmeter. SUS316L Housing. JIS 10, 20K RF, ASME/JPI 150 RF, IDF ferrule Applicable fluid

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display

Fuji Ultrasonic Flowmeter Series

SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER SYSTEM CONFIGURATION

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

High Performance Coriolis Flowmeters

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

Multifunction-Panelmeter

FLOMID FX Electromagnetic Flowmeter

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

Series 10-ZSE30A(F)/10-ISE30A

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

SITRANS F flowmeters. SITRANS F R Rotary-piston meters Accessory modules 4/431. Overview. Siemens AG 2009

IFC 010 Signal Converter

Introducing GPI s Latest

Straight-Tube Coriolis Flowmeter

SVM F27 / C27. Ultrasonic BTU meter for heating or cooling. Data sheet

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

LQ510. Density (Consistency) Meter. Introduction. Specifications EJL- 123

KFS. Flap-type flow meter. Design and range of application

Cost-Effective Coriolis Flow Meters. PRO Series Meters

LZYN Triangle Series Mass Flow Meter

WATERFLUX 3000 Quick Start

Density (Consistency) Meter LQ500

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)

F-SERIES FOR. Indicators Totalizers Transmitters Flow computers Batch controllers Monitors. Flow Level Pressure Temperature

WATERFLUX 3000 Quick Start

Efcon Water. Installation & User Manual Electro Magnetic Flowmeter (EMF) Efcon Water compact Electro Magnetic Flowmeter (EMF) Manual Version UK

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

WATER METERS M SERIES WATER METERS INSTALLATION, OPERATION AND MAINTENANCE GUIDE METAL M SERIES WATER METER PLASTIC M SERIES WATER METER

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

Dissolved Oxygen Transmitter

PAD - Heavy Duty Differential Pressure Trasmitter

Inductive Proximity Sensor

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

Ambient Conditions. Operating Conditions. Pressure

INFOCAL 8 Energy calculator

Emotron FDU 2.0 Variable Speed Drive

ULTRASONIC FLOW METER FT101

SONOMETER TM 1100 Ultrasonic compact energy meter

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

FLOMID-MX Control unit for electromagnetic flowmeters USERS MANUAL. instrumentación para fluidos. Realitzat: Revisat R+D Electrònic: Aprovat: Data:

Density (Consistency) Meter

Electric Actuator/ High Rigidity Slider Type

Introduction. Specifications LF620,LF622. Field Intelligent Device Series Electromagnetic Flowmeter Converter

X-band Magnetron. Cooling (note 5) Water Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

Q water 5.5. Electronic water meter. Data sheet DST1-QWA5-EN0 WMEAP / V 2.1

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

GC83 Digital Indicators & GC93 Digital Meter Relay

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

Magnetic-Inductive flow Meter fmi

OPTIFLUX 1000 Technical Datasheet

Wireless Pulse Transmitter and Receiver System. Ideal for slumpstand wireless metering application

Emotron FDU 2.0 Variable Speed Drive

SN+ MID MASTER + APPLICATION WATER METERS

mass flowmeter for compressed air

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

Electronic Vacuum Regulator. Standard Specifications. Model Voltage

Model Sono-Trak Transit Time

Section 11 Electronic Position Controls & Encoders

SLW-Tri Series Sanitary Hygienic Liquid Turbine Flow Meter

Series 10-ZSE80/10-ISE80

RCM DIRECT READING FLOWMETER

Electronic Heating Energy Meters

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

Convex Strainers DN PN 80, 100, 200

Flow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS380 standard. 4/254 Siemens FI Overview

Proportional Directional Control Valves Nominal sizes 16 and 25

MTS AND MTS PR¼ 16 OUTPUT SEQUENTIAL TIMER PENTAIR CLEAN AIR SYSTEMS

AEI800L Avid extreme Liquid Cooled Inverter Module Data Sheet REV 00, March AEI800L Liquid Cooled Inverter Module Data Sheet

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Flow Measurement SITRANS F US Inline

EN-2018 MAGNETIC FLOW METERS

OPTIFLUX 5000 Technical Datasheet

Residential Water Meters

wprime TM Series 280W-CI ULTRASONIC WATER METER

EC type-examination certificate UK/0126/0086 Revision 4

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

IS-3000 SERIES INFRARED SCANNER

Transcription:

FLOWPET-NX (Oil Service Mechanical Register) GENERAL SPECIFICATION GS.No.GBB322-6-E GENERAL Flowpet-NX is an OVAL flowmeter primarily developed for boiler feed water and fuel oil measurement. Field proven for consistent metering accuracy and long life combined with its ease of use and economy make this industrial instrument ideally suited for heat control applications as a dedicated flowmeter. FEATURES 1. Mechanical register equipped model is also available which requires no power source for oil service. 2. Can furnish reliable pulses to a total counter and a highspeed pulse output to a flow indicator. GENERAL SPECIFICATIONS Flow Ranges Model LS5076-2OOA LS5276-2OOA LS5376-2OOA LS5576-2OOA LS5676-2OOA Nominal Size mm Flow Range, L/h Flange Rating Kerosene Gas Oil (heavy oil A) Heavy oil (Above 0.8mPa s to 2mPa s) (Above 2mPa s to 5mPa s) (Above 5mPa s to 200mPa s) 20 JIS 10K RF, 150~ 1600 80~ 2000 50~ 2000 25 JIS 10K RF, 300~ 3000 150~ 3800 80~ 3800 40 JIS 10K RF, 600~ 5000 300~ 6400 150~ 6400 40 JIS 10K RF, 1200~11000 600~14000 400~14000 50 JIS 10K RF, 2000~20000 1400~24000 900~24000 Meter Body Operating temp. range (fluid temp.) 0 ~ 120 C Max. operating pressure 1.18MPa Linearity ±0.35% of RD Material Body FC250 Rotors Special resin Flow directions ] Right left (standard), left right, bottom top, top bottom Coating color Munsell 2.5 YR 6/13 Install the meter such that the pipe always remains filled with oil. See instruction manual if changing flow direction is desired. OVAL Corporation http://www.oval.co.jp Head Office: Tokyo; Tel. 81-3-3360-5121. Fax 81-3-3365-8605 Beijing Office: Tel., Fax. 86-10-6525-3601. Tel. 86-10-6513-3516 Overseas Branch Offices: Seoul. Singapore. Taipei

Mechanical Register Specifications Functions Display Output Pulse Operating Temp. Range Construction Material Finish (housing) Cumulative counter with dial-and-pointer, 6-digit number wheels LS5076, LS5276 LS5376, LS5576, LS5676 One pointer rev. 1L 10L Resolution 0.01L 0.1L Counter capacity 999,999.99L 9,999,999.9L See next section. 10 ~ +60 C Waterproof conforming to IP65 (weathertight) Resin/Aluminum die casting Munsell 4.9PB4.0/13.9 (color of molding) Factored Pulse Generator in Mechanical Register (option) MR sensor Reed switch Type of Output Pulse Voltage pulse/open collector Contact-closure pulse Number of Pulses (per pointer rev.) 10 P 1 P Pulse Width 1ms min. Duty Factor 40/60 ~ 60/40 ON: 6.5V min. Voltage pulse Output Signal Levels OFF: 1V max. Open collector ON: 1V max. Max. Operating Current 30mA 60mA (200Ω protective resistor provided) Max. Operating Voltage 40V DC (open collector) 125V AC, 50V DC Contact Bounce 0.5ms max. Life 5 X 10 7 cycles of operation (with resistive load at 12V DC, 10mA) Signal Cable Vinyl-insulated, 4-conductor, shielded (core wire 0.5mm 2, 4 ~ 10mm in O.D.) Transmission Distance 1 kilometer max. (using a CVVS cable 1.25 ~ 2.0mm 2 ) Power 12 ~ 24VDC ±10% Current Drain 20mA max. Mechanical Register Pulse Output Model Nominal Size mm MR Sensor Pulse Units Pulse Units at Max. Flow Rate Reed Switch Pulse Units Output Freq. Output Freq. at Max. Flow Rate Max. Flow Rate L/h LS5076-2 OOA 20 0.1 L/P 5.5 Hz 1 L/P 0.55 Hz 2000 LS5276-2 OOA 25 0.1 L/P 10.5 Hz 1 L/P 1.05 Hz 3800 LS5376-2 OOA 40 1 L/P 1.8 Hz 10 L/P 0.18 Hz 6400 LS5576-2 OOA 40 1 L/P 3.8 Hz 10 L/P 0.38 Hz 14000 LS5676-2 OO A 50 1 L/P 6.7 Hz 10 L/P 0.67 Hz 24000 2

OUTLINE DIMENSIONS [Unit in mm] L Approx. 86 t 21 B A 8 7 0 9 1 2 1 2 3 4 5 6 6 4 5 2 3 D 100 d P.C.D. n h Cable Connector (Furnished only for pulse generator equipped models) Model Nominal Flange Mass Size A B L d D t P.C.D. n-øh kg LS5076-2 OO A 20 162.5 117.5 150 100 18 75 4-15 3.9 LS5276-2 OO A 25 175.5 120.5 225 125 18 90 4-19 7.1 LS5376-2 OO A 40 189.5 131.5 225 140 20 105 4-19 8.5 LS5576-2 OO A 40 213.5 145.5 230 140 20 105 4-19 11.8 LS5676-2 OO A 50 240.5 153.5 250 155 20 120 4-19 18.2 JIS 10K RF dimensions shown. For, consult factory.. METER ERRORS AND PRESSURE LOSSES +0.5 Meter Error (%) with kerosene (1.2mPa s) Meter sizes 50 52 53 55 56 Meter Error (%) 0 0.5 Pressure Losses with heavy oil (19mPa s) 60 50 40 30 20 10 Pressure Loss (kpa) 0 25 50 75 100 Flow Rate (%) 3

PRODUCT CODE EXPLANATION Product Code Model L S Dedicated OVAL flowmeter 5 0 20A JIS 10K RF 5 2 25A JIS 10K RF Meter Size 5 3 40A JIS 10K RF 5 5 40A JIS 10K RF 5 6 50A JIS 10K RF Model Name 7 Flowpet-NX Application 6 _ Oil service Register Type 2 Mechanical register 1 L Units of Reading 2 Gallons (option) 0 Non pulse generator (standard) 1 Open-collector pulse generator provided. Factored pulse 10P/rev. (option) Pulse Generator 2 Voltage pulse generator provided. Factored pulse 10P/rev. (option) 3 Contact-closure pulse generator provided. Factored pulse 1P/rev. (option) Others A Always A STRAINERS General Do not fail to directly couple a strainer upstream of the Flowpet-NX. A strainer safeguards the Flowpet-NX against foreign particles and other suspended matter which could cause costly downtime. Specifications Operating Temp. Range (fluid temp.) Max. Operating Pressure 0~120 C 1.18MPa Material Body Net FC250 SUS304 Coating color Munsell 2.5 YR 6/13 Product Code, Outline Dimensions [Unit in mm], Net Mesh, Pressure Losses Product Nominal Size Flange Approx. Net Pressure Loss(kPa) at Max. Flow Rate Applicable L A Code Nom. Flange Rating D t P.C.D. n-øh Mass kg Mesh Kerosene 1.2mPa s Heavy oil 19mPa s Flowpet-NX SS5277A 20A JIS 10K RF 125 85 100 18 75 4-15 3.4 80 6( 1600L/h) 50( 2000L/h) LS5076-2 OOA SS5377A 25A JIS 10K RF 140 105 125 18 90 4-19 5.3 60 7( 3000L/h) 28( 3800L/h) LS5276-2 OOA SS5577A 40A JIS 10K RF 170 130 140 20 105 4-19 7.7 60 23(11000L/h) 26( 14000L/h) LS5376-2 OOA LS5576-2 OOA SS5677A 50A JIS 10K RF 190 140 155 20 120 4-19 9.6 60 25(20000L/h) 40( 24000L/h) LS5676-2 OOA JIS 10K RF dimensions shown. For, consult factory.. 4

REMOTE FLOW MEASUREMENT WITH FLOWPET-NX Pulse generator equipped Flowpet-NX provides the operator with a quick indication of the process for absolute control of oil supply at a remote location. 8-digit LCD counter Display capabilities remain the same as the electronic register integralwith the Flowpet-NX. Accumulated total flow Instantaneous flowrate (hourly, per-minute) Resettable total Totalizer EL0123 (operating on a built-in battery) EL0122 (operating on an external power) 1~5VDC F/I converter SU1312-O61000 4~20mADC Recorder Unfactored pulse 0~100µADC Flowpet-NX (Open-collector pulse) Factored pulse F/I converter SU1315-O61000 Indicator EL1123 Printer PR-101M Local Control Room Small totalizer (commercially available) Input: Frequency 1kHz max. Open collector pulse Battery built-in (external power not required) (6-digit manual reset or 7-digit remote reset) The pulse signal generated from an electronic register equipped Flowpet-NX is of open collector pulses both for total counter and flow indicator. F/I converter (frequency-current (voltage) transforms the unfactored pulse signal from the Flowpet-NX to a current or voltage signal. For detailed specifications of converters and receiving instruments, see respective general specifications separately prepared. 5

OPERATING PRECAUTIONS To derive maximum benefit and safety of operation from the Flowpet-NX, we recommend that the following precautions be taken: 1. From the flow ranges and operating ranges of the flowmeter, strainer and other available data, select the right pump and valve location to ensure that the required flow rate, pressure and other factors be maintained and that excessive flow rates, pressure rises or other damaging conditions be prevented. 2. In cold regions, take due precautions against freezing. The meter body and strainer are not serviceable at subzero temperatures. 3. Locate the flowmeter itself and signal cable sufficiently away from sources of large magnetic fields (e.g., pumps, electric motor-driven and solenoid valves). (For example, keep a solenoid valve 10 watts or so in power consumption at least 10 centimeters away.) 4. Acceptable fluids depend on the type of flowmeter. The Flowpet-NX is primarily designed for boiler feed water and fuel oil. If you have any other application in mind, seek our service for application assistance. The specification as of April, 2003 is stated in this GS Sheet. Specifications and design are subject to change without notice. Sales Representative: