COOPER POWER SERIES. Upgrade instructions for CL-6 series control firmware. Voltage Regulators MN225071EN

Similar documents
COOPER POWER SERIES. External application of a motor start capacitor on a single-phase voltage regulator. Voltage Regulators MN225063EN

Effective November 2017 Supersedes May 2017

COOPER POWER SERIES. Slip-On bushing current transformer kits KA712L1S, KA712L2S, KA712L3S, and KA712L5S installation instructions and technical data

Series NRX with PXR - Instructions for Neutral Current Sensor Type NF

Arc Sensor User Manual

Magnum low voltage drawout circuit breaker IEC horizontal stab cassette shutter kit (double wide A cassettes)

COOPER POWER SERIES. Substation frame KA89WV1 and accessories assembly and installation instructions. Reclosers MN280044EN

MN E. Waveform Viewer: Power Xpert Software 2.2

INSTRUCTION LEAFLET IL17537B F FRAME IQ ENERGY SENTINEL TM INSTALLATION INSTRUCTIONS FOR F FRAME IQ ENERGY SENTINEL TM

A1000 ALPHA and A1200 ALPHA Meter Installation Instructions. General. Installation. For A1000 ALPHA Type R, A1000 ALPHA Type C, and A1200 ALPHA Meters

A1800 ALPHA meter special installation instructions DANGER

Pushbutton Bollard. Wireless Control for BlinkerSign, RRFB or BlinkerBeacon User Guide. Blinker Division Solar LED Solutions

GridAdvisor Series II smart sensor installation instructions

LD2342 USWM V1.6. LD2342 V1.4 Page 1 of 18

UM10950 Start-up Guide for FRDM-KW41Z Evaluation Board Bluetooth Paring example with NTAG I²C plus Rev February

4S, 5S, 5A, 6S, 6A, 8S, 9S, 10S, 10A, 26S, 29S, 35S, 35A, 36S,

INSTRUCTION LEAFLET IL17553B IQ UNIVERSAL POWER SENTINEL TM INSTALLATION INSTRUCTIONS FOR THE IQ UNIVERSAL POWER SENTINEL TM INTERNAL CT

PHASE ROTATION METER. Operating and Instruction Manual. a n d A C C E S S O R I E S

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

Owner s Manual & Safety Instructions

Radio Remote Controls Manual K Series

14 Piece Slide Hammer and Puller Set

Owner s Manual & Safety Instructions

ALPHA meter. General. Installation instructions IL S

9 PIECE TUNGSTEN CARBIDE HOLE SAW KIT. Model 90721

TAG5000 WIRELESS PHASER. Instruction Manual HD ELECTRIC COMPANY 1475 LAKESIDE DRIVE WAUKEGAN, ILLINOIS U.S.A.

ER200 COMPACT EMERGENCY CRANK DIGITAL WEATHER ALERT RADIO OWNER S MANUAL

Field Device Manager Express

Specifications. Important Safety Information

UM DALI getting started guide. Document information

Oberebenestrasse Bremgarten Switzerland Tel Fax

15 Planer Stand. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

BB Product profile. 2. Pinning information. 3. Ordering information. FM variable capacitance double diode. 1.1 General description

SRT Marine Technology. LD2342 V1.4 Page 1 of 22

Agilent ParBERT Measurement Software. Fast Eye Mask Measurement User Guide

UM DALI getting started guide. Document information

Nashville Etagere/Bookcase

75 MHz, 30 db gain reverse amplifier

TED-Kit 2, Release Notes

BAP Product profile. 2. Pinning information. 3. Ordering information. Silicon PIN diode. 1.1 General description. 1.2 Features and benefits

Field Hub Installation Guide. P/N Rev. C 05/15

SINAMICS drives SINAMICS DCM. DC converters from 6 kw to 2500 kw for variable-speed direct-current drives

Using the USB Output Port to Charge a Device

Radio Remote Controls Manual K Series

VT1586A Rack Mount Terminal Panel Installation and User s Manual

VHF variable capacitance diode

Administration Guide. BBM Enterprise. Version 1.3

SINAMICS drives. SINAMICS DCM as a DC voltage source. Application. Answers for industry. Edition 01/2014

Two elements in series configuration in a small SMD plastic package Low diode capacitance Low diode forward resistance AEC-Q101 qualified

Single Flex and Double Flex Couplings (i)

Planishing hammer stand For use with SKU Planishing hammer

User Manual. Smart-UPS On-Line. Uninterruptible Power Supply. Isolation Transformer Models: SURT001 and SURT002

Analog Voltage Detector 1-450kV Operating Instructions VDAO450TM. Patent No. 6,275,022

Planar PIN diode in a SOD523 ultra small plastic SMD package.

MWC2-9. Operation Manual. MWC MHz Receiver with FM Radio Option. Radio. manmwc29_v7

Shrinker and stretcher

10 Ton Pull Back Ram

INSTALLATION INSTRUCTIONS

HT1100 Satellite Modem User Guide

Quad 2-input NAND buffer (open collector) The 74F38 provides four 2-input NAND functions with open-collector outputs.

HEF4001B. 1. General description. 2. Features and benefits. 3. Ordering information. 4. Functional diagram. Quad 2-input NOR gate

Planar PIN diode in a SOD523 ultra small SMD plastic package.

Hex non-inverting precision Schmitt-trigger

Metal Oxide Varistor Elbow (M.O.V.E.) Surge Arrester

Four planar PIN diode array in SOT363 small SMD plastic package.

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

Model DB Disc Caliper Brake AIR CHAMP PRODUCTS. User Manual. (i) MTY (81)

In data sheets and application notes which still contain NXP or Philips Semiconductors references, use the references to Nexperia, as shown below.

MANUAL METAL SHRINKER/STRETCHER

Analog Voltage Detector 0-40kV Operating Instructions VDA040CTM

12-stage binary ripple counter

Horizontal Mezzanine Gate

200 MHz, 35 db gain reverse amplifier. High performance amplifier in a SOT115J package, operating at a voltage supply of 24 V (DC).

2015 RIGOL TECHNOLOGIES, INC.

The 74LVT04 is a high-performance product designed for V CC operation at 3.3 V. The 74LVT04 provides six inverting buffers.

HEF4002B. 1. General description. 2. Features and benefits. 3. Ordering information. 4. Functional diagram. Dual 4-input NOR gate

INSTRUCTION MANUAL INF Fax: (503)

Service Manual for Installers Troubleshooting for Power-Line Communication SUNNY BOY 240-US / SUNNY MULTIGATE-US

Contents. Overview Introduction...3 Capabilities...3 Operating Instructions Installation...4 Settings... 5

ER200 COMPACT EMERGENCY CRANK DIGITAL WEATHER ALERT RADIO OWNER S MANUAL

Quad R/S latch with 3-state outputs

Hex non-inverting HIGH-to-LOW level shifter

Hex inverting HIGH-to-LOW level shifter

OWNER S MANUAL: Adjustable Height Wall Rack

Keychain Radio Remote Control System

DATASHEET 4D SYSTEMS. Arduino Display Module Pack TURNING TECHNOLOGY INTO ART. Featuring a 2.4 Display Module ulcd-24-ptu-ar

R_ Driving LPC1500 with EPSON Crystals. Rev October Document information. Keywords Abstract

NPN power transistor with integrated diode

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

BC145 SIGNAL ISOLATOR BOARD

16-bit buffer/line driver; 3-state

Planar PIN diode in a SOD882D leadless ultra small plastic SMD package.

1-of-4 decoder/demultiplexer

74HC9114; 74HCT9114. Nine wide Schmitt trigger buffer; open drain outputs; inverting

User Manual January Opticom Infrared System RC790 Remote Coding Unit

Installation Instructions

41P Portable Calibrator User Manual

ATV CULTIVATOR OWNER S MANUAL

Planning and Installing the EnergyAxis System Starter Kit. Introduction. Related Documents

Broadband LDMOS driver transistor. A 5 W LDMOS power transistor for broadcast and industrial applications in the HF to 2500 MHz band.

Transcription:

Voltage Regulators MN225071EN Effective March 2017 Supersedes September 2012 (S225-11-4) COOPER POWER Upgrade instructions for CL-6 series control firmware SERIES

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information, recommendations, descriptions and safety notations in this document are based on Eaton Corporation s ( Eaton ) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser. THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and descriptions contained herein. The information contained in this manual is subject to change without notice. i

Contents DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY... i Safety for life... iii Safety information... iii Safety instructions... iii Upgrading firmware... 1 Duty cycle monitor values...1 Upgrade instructions.... 1 ii

! SAFETY FOR LIFE Safety for life Eaton s Cooper Power series products meet or exceed all applicable industry standards relating to product safety. We actively promote safe practices in the use and maintenance of our products through our service literature, instructional training programs, and the continuous efforts of all Eaton employees involved in product design, manufacture, marketing and service. We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around high-voltage lines and equipment and support our Safety For Life mission.! SAFETY FOR LIFE Safety information The instructions in this manual are not intended as a substitute for proper training or adequate experience in the safe operation of the equipment described. Only competent technicians, who are familiar with this equipment should install, operate and service it. A competent technician has these qualifications: Is thoroughly familiar with these instructions. Is trained in industry-accepted high and low-voltage safe operating practices and procedures. Is trained and authorized to energize, de-energize, clear, and ground power distribution equipment. Is trained in the care and use of protective equipment such as flash clothing, safety glasses, face shield, hard hat, rubber gloves, clampstick, hotstick, etc. Following is important safety information. For safe installation and operation of this equipment, be sure to read and understand all cautions and warnings. Hazard Statement Definitions This manual may contain four types of hazard statements: DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in equipment damage only. Safety instructions Following are general caution and warning statements that apply to this equipment. Additional statements, related to specific tasks and procedures, are located throughout the manual. DANGER Hazardous voltage. Contact with hazardous voltage will cause death or severe personal injury. Follow all locally approved safety procedures when working around high- and low-voltage lines and equipment. WARNING Before installing, operating, maintaining, or testing this equipment, carefully read and understand the contents of this manual. Improper operation, handling or maintenance can result in death, severe personal injury, and equipment damage. WARNING This equipment is not intended to protect human life. Follow all locally approved procedures and safety practices when installing or operating this equipment. Failure to comply can result in death, severe personal injury and equipment damage. WARNING Power distribution and transmission equipment must be properly selected for the intended application. It must be installed and serviced by competent personnel who have been trained and understand proper safety procedures. These instructions are written for such personnel and are not a substitute for adequate training and experience in safety procedures. Failure to properly select, install or maintain power distribution and transmission equipment can result in death, severe personal injury, and equipment damage. iii

Upgrade instructions for CL-6 series control firmware NNote: Please read this bulletin prior to updating firmware. Upgrade instructions Upgrading firmware Duty cycle monitor values If your voltage regulator does not include a Quik-Drive tap-changer, proceed directly to the Upgrade Instructions in the next column. To determine the type of tap-changer in your unit, select FC 49 and verify it by noting the tap-changer type on nameplate. Regulators that contain a Quik-Drive tap-changer and have been in service must have the Duty Cycle Monitor (DCM) information recorded and entered back into the control after the firmware upgrade. To maintain the DCM values, the following steps must be performed prior to uploading the firmware. 1. Connect PC to CL-6 control using an RS-232 cable. 2. Open the ProView NXG software, and start communications with the control. For more information on connecting to the control view the section titled Connecting to the CL-6 Series Control in the software help files. 3. In ProView NXG software, select Display > Duty Cycle... 4. Write down the largest number in the percent-consumed column. 5. Select Settings > Configure Duty Cycle... 6. Write down the DCM Spec. Number displayed in the top line. 7. Follow the Firmware Upgrade Instructions in the next column and then complete the instructions below. To maintain the DCM values, the following steps must be performed after uploading the firmware. 1. When the upgrade process is complete, again connect your PC to the CL-6 control and begin communicating. 2. In the ProView NXG software select Settings > Configure Duty Cycle... 3. Select the proper DCM Spec. Number from the dropdown menu in the second line and enter the Initial Level (%) recorded earlier. 4. Click on the Apply button in the DCM Configuration dialog box. 5. Click on the Refresh button and confirm that the DCM Spec. Number and Initial Level (%) values loaded properly. You can also check that the % consumed has loaded properly by checking FC 333 on the control display. 1. Download the latest firmware from www. cooperpowercentral.com directly onto a compact flash card into the root directory, and unzip the file. Once the file is on a compact flash card, extract, or unzip it directly back to the root directory of the compact flash card. It is possible to download the file to your computer hard drive; however, do not unzip the file until after it is copied to a compact flash card. 2. Insert the compact flash card and save the standard settings. Insert the compact flash card and select FC 354. Press Enter, Enter and Enter to confirm. This will save the settings from the control to the compact flash card. Once this is complete, take note and write down the values displayed at FC 40, Regulator ID and the value at FC 0, Total Operations Counter. These values will be overwritten on a major firmware upgrade and must be reentered manually. 3. Leave the compact flash card in the control and load the firmware. To load the firmware: turn the power to the control off. While simultaneously holding down the Enter and Escape keys, turn the power back on. The LCD display will display Bootloader v1.01 and Erasing Block You can now let go of the Enter and Escape keys. The Firmware is loading. This process takes approximately two minutes. 4. Confirm firmware upgrade. Once the firmware is loaded, you may have a Diagnostic Error and the Diagnostic Error LED may be lit; ignore this for now. Press the Escape key and enter FC 89 to show the firmware version; make sure that the upgrade took effect. If it has not loaded properly, go back to Step 3 and attempt the load again. If it still does not load properly, you may need to download and unzip the firmware file again. 5. Load standard settings, Regulator ID and Total Operations Counter information back onto the control. Enter the security code (default code is 32123) at FC 99. Reload the settings onto the control using FC 352. Enter the Regulator ID into the control using FC 40. Enter the Total Operations into the control using FC 0. 6. Initiate a self-test to verify that the diagnostic errors clear. Do this by pressing Function, 91, Enter, Enter, and Enter to confirm. 7. Troubleshoot diagnostic errors messages displayed after the self-test. Refer to Section 8: Troubleshooting of the document MN225016EN, CL-6 Series Control Installation, Operation, and Maintenance Instructions. If the control indicates PASS, the firmware upgrade is complete. 1

Upgrade instructions for CL-6 series control firmware This page intentionally left blank. 2

Upgrade instructions for CL-6 series control firmware This page intentionally left blank. 3

! SAFETY FOR LIFE Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton s Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries 2017 Eaton All Rights Reserved Printed in USA Publication No. MN225071EN March 2017 Eaton is a registered trademark. All trademarks are property of their respective owners. For Eaton s Cooper Power series product information call 1-877-277-4636 or visit: www.eaton.com/cooperpowerseries.