User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

Similar documents
User s Guide. Digital AC/DC Clamp Meter Model 38394

User Guide. Digital AC/DC Clamp Meter Model 38394

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

Pen Multimeter. Model

Pen Multimeter. Model

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

200Amp AC Clamp Meter + NCV Model MA250

User s Guide. 400A AC/DC Clamp Meter. Model MA220

True RMS AC / DC Power Clamp Meter Model

User s Guide. Model MA A AC Mini Clamp-on Meter

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

Passive Component LCR Meter

Autoranging Multimeter Extech EX503

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

User's Manual. Clamp-on Power Datalogger. Model

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

Passive Component LCR Meter

OPERATOR S INSTRUCTION MANUAL

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

User's Manual. Model f/1f Power Clamp-on Meter

High Temperature InfraRed Thermometer with Laser Pointer

DMM8900 SERIES USERS MANUAL

User's Guide. Wireless AC Circuit Identifier. Models RT30 and RT32

INSTRUCTION MANUAL DIGITAL MULTIMETER

User s Guide. Combination Photo-Tachometer Stroboscope Model

AUTO RANGING DIGITAL MULTIMETER

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

AMM-1022 Digital Multimeter USER`S MANUAL

USER'S MANUAL DMR-6700

400Amp True RMS AC/DC Clamp Meter Model EX613

Non-contact Forehead IR Thermometer

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

M-1000D DIGITAL MULTIMETER

Item ref: UK MTM01 DIGITAL MULTITESTER. User Manual

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Dawson DDM190. Digital Multimeter User s Manual

DIGITAL MULTIMETER. MODEL CDM-50 Part No OPERATING INSTRUCTIONS

USER'S MANUAL DMR-4300

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

DVM1190 DIGITAL MULTIMETER

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

User s Manual. Ground Resistance Clamp On Tester MODEL

DIGITAL MULTIMETER OPERATING INSTRUCTIONS MODEL CDM-35. Part No

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

Sales: Technical: Fax:

400Amp True RMS AC Clamp Meter + NCV

Digital Multimeter with Backlight

ProfiScale MULTI Multimeter

Model Digital Light Meter

DIGIT & POINTER MULTIMETER

Owner's Manual English / Español

Analog Technologies VC99. Multimeter FEATURES

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

DIGITAL MULTIMETER INSTRUCTION MANUAL

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

R/C SMD Tweezers Multimeter Model RC200

VC835 DIGTAL MULTIMETER Operation Manual

NOTE: Fully read and understand this manual before using this Digital Multimeter.

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

Compact MultiMeters + Voltage Detector

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

Handheld Digital Multimeter PRO-50A

Model & MultiScope TM

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

DM-46 Instruction Manual

INSTRUCTION MANUAL MODEL 21 MULTI-TESTER

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

USER'S MANUAL DMR-2400

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

User Guide. AC/DC Mini Clamp Meter. Model

Model DIGITAL MULTIMETER

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

DDM350 Pen-Type Digital Multimeter User s Manual

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

DIGITAL MULTIMETER AX-588B

User Manual. All rights reserved. Specifications are subject to change without notice.

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Accuracy : ± (0.8% rdg + 1dgt) on all ranges except Ranges : 200mV, 2V, 20V, 200V, 1000V

Heavy Duty Meter Model

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL- KM 2782 / 2782-T

Model True RMS AC/DC 30A Mini Clamp-on Meter. User Guide

RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL

AUTORANGING TRUE RMS MULTIMETER USER GUIDE. INST151 Doc 1.00

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

DM-46 Instruction Manual

Digital Multimeter AX-572. Instruction manual

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

1.General instructions Specifications Description...7

User Manual Digital Multimeter

AM-520 AM-530. Users Manual. HVAC Multimeter. True-rms Electrical Contractor Multimeter

Transcription:

User s Guide MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

WARRANTY EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies on sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. REPAIR AND CALIBRATION SERVICES Extech offers complete repair and calibration services for all of the products we sell. For periodic calibration, NIST certification or repair of any Extech product, call customer service for details on services available. Extech recommends that calibration be performed on an annual basis to ensure calibration integrity. Copyright 2002 Extech Instruments Corporation. All rights reserved including the right of reproduction in whole or in part in any form. V1.2 04/02 Tech Support Hotlines 781-890-7440 ext. 200 extech@extech.com www.extech.com

Introduction Congratulations on your purchase of Extech model MV-110, MV-120, or MV-130 digital multimeter. Properly used, this meter will provide many years of reliable service. The meters contains a large 3-1/2 or 4-1/2 digit LCD with adjustable viewing angle and provides such measurement functions as: DC and AC voltage, DC and AC current, resistance, temperature, frequency, capacitance, hfe, battery, square wave output, diode, and continuity check depending upon the model. Safety International Safety Symbols WARNING: This indicates that a potentially hazardous condition which, if not avoided, could result in death or serious injury. CAUTION: This indicates that a potentially hazardous condition which, if not avoided, could result in injury or damage to the meter. Refer to the manual Hazardous voltages Double insulation for further information may be present.

Safety Precautions 1. WARNING: Improper use of this meter can cause damage, shock, injury or death. Read and understand this users manual before operating the meter. 2. Make sure any covers or battery doors are properly closed and secured. 3. Always remove the test leads before replacing the battery or fuses. 4. Inspect the condition of the test leads and the meter itself for any damage before operating the meter. Repair or replace any damage before use. 5. Do not exceed the maximum rated input limits. 6. Use great care when making measurements if the voltages are greater than 25VAC rms or 35VDC. These voltages are considered a shock hazard. 7. Always discharge capacitors and remove power from the device under test before performing Capacitance, Diode, Resistance or Continuity tests. 8. Remove the battery from the meter if the meter is to be stored for long periods.

Specifications General Specifications Display 1999 count 3 1/2 digit, adjustable angle (MV-110, MV-120) 19999 count 4 1/2 digit, adjustable display (MV-130) Sample Rate Approximately 2-3 per second Input warning Alarm sounds with test leads in the A or 10A socket and the wrong function is selected. Fuse Protection 2A (A socket), 0.2A (ma socket), 10A or 20A range not fused Power Supply 9V battery (NEDA 1604 or equivalent) Range selection Manual Over-range Indication "1" Auto Off Unit switches off after 15 minutes of inactivity Low Battery Indication battery symbol Operating Temperature / 32 0 F to 104 0 F (0 0 C to 40 0 C) / < 75% RH Humidity Storage Temperature 14 0 F to 122 0 F (-10 0 C to 50 0 C) Dimension / Weight 7.3 x 3.5 x 1.3" (185x89x32mm) LxWxH / approx. 9.7 oz. (300 grams)

Electrical Specifications Function (model) Range Accuracy % Rdg. + digits Resolution Input Protection DCV 200mV ±(0.5% + 1 digit)\ 0.1mV 250V rms (MV-110, MV-120) 2, 20, 200V 0.001,0.01,0.1V 1000VDC 1000V ±(0.8% + 2 digit) 1V 750VAC DCV 200mV ±(0.05% + 3digits) 0.01mV 250V rms (MV-130) 2, 20, 200V 0.0001,0.001,0.01V 1000VDC 1000V ±(0.1%+ 5 digits) 0.1V 750VAC ACV 200mV ±(1.2% + 3 digits) 0.1V 1000VDC (MV-110, MV-120) 2, 20, 200V ±(0.8% + 3 digits) 0.001,0.01,0.1V 750VAC 750V ±(1.2% + 3 digits) 1V ACV 2, 20, 200V ±(0.8% + 10 digits) 0.0001,0.001,0.01V 1000VDC (MV-130) 750V ±(1.0% + 15 digits) 0.1V 750VAC DCA 20µA ±(2.0% + 5 digits) 0.01µA 2A,250V fuse (MV-110) 200µA, 2, 20 ma ±(0.8% + 1 digits) 0.1µA, 0.001,0.01mA 200mA, 2A ±(1.2% + 1 digits) 0.1mA, 0.001A 10A ±(2.0% + 5 digits) 0.01A not fused DCA 20, 200 ma ±(0.8% + 1 digits) 0.01, 0.1mA 0.2A,250V fuse (MV-120) 20A ±(2.0% + 5 digits) 0.01A not fused Comments Input impedance > 10MΩ Input impedance > 1MΩ Frequency range: <200V: 40 to 400Hz, < 750V: 40 to 200Hz 15 sec. max @ 20A

Function Range Accuracy % rdg. + digits Resolution Input Protection Comments DCA 2, 20, 200mA ±(0.8% + 10 digits) 0.0001,0.001,0.01mA 0.2A,250V fuse (MV-130) 10A ±(2.0% + 10 digits) 0.001A not fused ACA 20µA ±(3.0% + 7 digits) 0.01µA 2A,250V fuse Frequency: 40 to 400Hz (MV-110) 200µA ±(1.8% + 3 digits) 0.1µA Maximum input: 2, 20mA ±(1.0% + 3 digits) 0.001, 0.01mA 10A (MV-110, MV-130), 20A (MV-120) 200mA, 2A ±(1.8% + 3 digits) 0.1mA, 0.001A Average responding 15 sec. max @ 20A 10A ±(3.0% + 7 digits) 0.01A not fused ACA 20, 200 ma ±(1.0% + 3 digits) 0.01,0.1mA 0.2A,250V fuse (MV-120) 20A ±(3.0% + 7 digits) 0.01A not fused ACA 6 2, 20 200mA ±(1.0% + 10 digits) 0.0001,0.001,0.01mA 0.2A,250V fuse (MV-130) 10A ±(2.0% + 10 digits) 0.001A not fused Resistance 200Ω ±(0.8% + 3 digits) 0.1Ω (MV-110, MV-120) 2, 20, 200kΩ, 2MΩ ±(0.8% + 1 digits) 1, 10, 100Ω,1kΩ 20MΩ ±(1.0% + 2 digits) 10kΩ 200MΩ ± (5.0% rdg +10d) +10 dig 100kΩ Resistance 200Ω ±(0.2% + 5 digits) 0.01Ω (MV-130) 2, 20, 200kΩ, 2MΩ ±(0.2% + 1 digits) 0.1, 1, 10, 100Ω 20MΩ ±(0.5% + 5 digits) 1kΩ 250V DC or ACrms Open circuit voltage <0.7V RH 200MΩ range: <75% RH other ranges: <90% On the 200MΩ range a 1.0MΩ offset exists. Subtract 1.0MΩ from all readings.

Function Range Accuracy % rdg + digits Resolution Input Protection Comments Capacitance (MV-120) 2,20,200nF 2,20µF ±(2.5% + 3 digits) 1,10,100pF 1nF, 10nF Test Freq: 400Hz Test V: 40mV Capacitance (MV-130) 2,20,200nF 2,20µF ±(2.5% + 10 digits) 0.1,1,10,100pF 1nF Temperature -18 to 400 0 C ±(0.75% + 4 digits) 1 o C/F Type K Thermocouple (MV-120) 0 to752 0 F -40 to 1000 0 C ±(1.6% + 15 digits) -40 to 1832 0 F Frequency (MV-130) 20kHz ±(1.5% + 10 digits) 1Hz 250VAC/VDC Sensitivity: 100mV Diode test Forward DC current approx. 1mA, Reverse DC voltage approx. 3V Transistor hfe 0 to 1000 Base current approx. 10uA, Vce approx 2.8V Continuity Buzzer sounds when R < 30Ω Battery check 1.5V 30Ω Internal resistance (MV-110) 9.0V 1.8kΩ Internal resistance Square Wave (MV-110) Approx. 50Hz, 4-6V Note: Accuracy is specified for a period of one year after calibration and at 18 o C to 28 o C (64 o F to 82 o F) RH: 75% max.

Description (MV120 pictured) 1. Display release button 2. AC/DC selection on models MV110, MV120 3. Hold Button on model MV130. 4. Power ON/OFF button 5. LCD display 6. Transistor socket 7. Function rotary switch 8. Capacitance socket (MV120, MV130) 9. V/F/Ohms socket 10. COM socket 11. Low Amperage socket 12. 10/20 Amp socket 13. Type K thermocouple input socket (MV120 only).

Operation General Procedures 1. Apply power via ON/OFF switch. If the low battery symbol appears, replace the battery. 2. Set the function switch to the correct position before taking measurements. 3. Press the Display Release Button and set the display to a convenient viewing angle. AC/DC Voltage Measurements (DO NOT EXCEED MAX INPUT LIMIT OF 1000VDC) 1. Connect the black test lead to the meter's COM socket and the red lead to the meter's "VΩF" socket. 2. Set the rotary switch to a "V" position range higher than the expected voltage. 3. Press the "DC / AC" button to select AC or DC measurement (for models MV-110 and MV-120 only). 4. Connect the test leads to the unit under test (load, circuit, etc.) 5. The value of the measured voltage will appear in the LCD display. Resistance Measurement 1. Connect the black test lead to the COM socket and the red lead to the V/Ω socket. 2. Set the rotary switch to the "Ω" range required. 3. Connect the test leads to the unit under test. 4. The value of the measured resistance will appear in the LCD display.

Diode Measurements 1. Connect the black test lead to the COM-socket and the red lead to the VΩ socket. 2. Set the rotary switch to the "Diode" symbol position 3. Connect the test leads to the diode under test. 4. The value of the forward voltage drop (0.3 to 0.6V) or the open circuit voltage (2.6V approx.) will appear in the LCD display for a good diode. AC/DC Current Measurements (If the magnitude of current is unknown, select the highest meter range and then reduce the range as needed) 1. Connect the black test lead to the meter's COM-socket and the red lead to either the "A" socket if measuring less than 2A or the "10A/20A" socket if measuring less than 10A or 20A 2. Set the rotary switch to the "A" position as required. Always select the highest range when unsure of the current value. 3. Press the "DC / AC" button to select AC or DC measurement. 4. Connect the test leads in series with the unit under test (load, circuit, etc.) 5. The value of the measured current will appear in the LCD. 6. Negative DC current will appear with a "-" sign. NOTE: The ma and A ranges are protected by a 0.2A or a 2A fuse. The 10A or 20A ranges are not fuse protected. Always replace blown fuses with fuses of the identical type.

Continuity Measurements (Remove power or voltage from the device under test) 1. Connect the black test lead to the COM-socket and the red lead to the VΩ socket. 2. Set the rotary switch to the "Continuity" symbol position 3. The continuity buzzer will sound if the measured resistance is < 30Ω Battery Measurements (MV-110 only) 1. Connect the black test lead to the COM-socket and the red lead to the VΩ socket. 2. Set the rotary switch to the 1.5V or 9V position 3. The meter will display the voltage under load of the tested battery. Square Wave Output (MV-110 only) Note: Remove power or voltage from the device under test 1. Connect the black test lead to the COM-socket and the red lead to the VΩ socket. 2. Set the rotary switch to the "square wave symbol" position 3. The meter will output a 50Hz square wave. Capacitance Measurements (MV-120, MV-130 only) Note: Remove power or voltage from the device under test 1. Insert the capacitor in the CAP socket. 2. Set the rotary switch to the proper capacitance position. 3. The value of the measured capacitor will appear in the LCD.

Temperature Measurements (MV-120 only) 1. Insert the type K thermocouple mini-connector into the "K" socket. 2. Set the rotary switch to the ºF or ºC position. 3. The value of the measured temperature will appear in the LCD. Transistor hfe Measurements 1. Move the rotary select switch to the hfe position 2. Plug the transistor under test into the appropriate transistor input jacks on the meter front. 3. For transistor types PNP and NPN, the meter has matching input sockets. Also, for each leg of the transistor (E, B, and C) the meter has matching input sockets. Plug the transistor into the sockets that match its type. 4. Read the hfe value on the LCD display. Auto Power Shut-Off To conserve battery power, the meter will automatically power down if it has not been used for more than 15 minutes. Battery Replacement Remove the test leads from the meter and remove the screw from the battery compartment cover (rear bottom). Lift off the cover, replace the battery, and replace battery cover.