INTERNATIONAL JOURNAL OF COMPUTER ENGINEERING & TECHNOLOGY (IJCET)

Similar documents
A New Approach Applied to Adaptive Centralized Load Shedding Scheme

Combination of Adaptive and Intelligent Load Shedding Techniques for Distribution Network

A Review of Adaptive Under Frequency Load Shedding Scheme on Islanded Distribution System Using MATLAB/SIMULINK

SCIENCE & TECHNOLOGY

Effect of Load Shedding Strategy on Interconnected Power Systems Stability When a Blackout Occurs

A Topology-based Scheme for Adaptive Underfrequency Load Shedding

Representing an intelligent load shedding algorithm with utilization of frequency deviation integration

A. df/dt Measurement principle by relays

System Protection and Control Subcommittee

ESB National Grid Transmission Planning Criteria

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 4: (June 10, 2013) Page 1 of 75

NVESTIGATIONS OF RECENT BLACK-

1

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 5: (August 2, 2013) Page 1 of 76

Stability Issues of Smart Grid Transmission Line Switching

ECE 692 Advanced Topics on Power System Stability 5 - Voltage Stability

Simulation Programs for Load Shedding Studies: Expermintal Results

SYNCHROPHASOR TECHNOLOGY GLOSSARY Revision Date: April 24, 2011

EH2741 Communication and Control in Electric Power Systems Lecture 2

DEVELOPMENT OF SMART UNDERFREQUENCY LOAD SHEDDING SYSTEM

An Improved Method of Adaptive Under Voltage Load Shedding

International Journal of Advance Engineering and Research Development

A Novel Approach for Assessing the Impacts of Voltage Sag Events on Customer Operations

NERC Protection Coordination Webinar Series June 23, Phil Tatro

Anti-IslandingStrategyforaPVPowerPlant

Modle 6 : Preventive, Emergency and Restorative Control. Lecture 29 : Emergency Control : An example. Objectives. A simple 2 machine example

The Coupling of Voltage and Frequecncy Response in Splitting Island and Its Effects on Load-shedding Relays *

Adaptive Relaying of Radial Distribution system with Distributed Generation

Keywords: Transformer, differential protection, fuzzy rules, inrush current. 1. Conventional Protection Scheme For Power Transformer

Optimal PMU Placement on Network Branches for Intentional Islanding to Prevent Blackouts

Study on the Improvement of the Special Protection Scheme (SPS) in the Korean power system

VOLTAGE STABILITY OF THE NORDIC TEST SYSTEM

ISSN Vol.07,Issue.21, December-2015, Pages:

Smart Grid Where We Are Today?

Performance of Relaying During Wide-area Stressed Conditions

Real-time Decentralized Voltage Stability Monitoring and Protection against Voltage Collapse

Optimal Voltage Regulators Placement in Radial Distribution System Using Fuzzy Logic

Islanding and Detection of Distributed Generation Islanding using Negative Sequence Component of Current

The Role of Effective Parameters in Automatic Load-Shedding Regarding Deficit of Active Power in a Power System

Use of the Power System Outlook (PSO) and SMART 1 Programs to View PSLF Dynamic Simulation Data Files

NERC Protection Coordination Webinar Series June 16, Phil Tatro Jon Gardell

Application of Fuzzy Logic Controller in UPFC to Mitigate THD in Power System

CHAPTER 6 ANFIS BASED NEURO-FUZZY CONTROLLER

TRADITIONALLY, if the power system enters the emergency

A Novel Fuzzy Neural Network Based Distance Relaying Scheme

Endorsed Assignments from ERS Framework

Controlled Islanding Followed by Load Shedding Based on Rate of Frequency Decline

Let X be a space of points, with a generic element of X denoted by x. Thus X = {x}.

Reliability Guideline: Generating Unit Operations During Complete Loss of Communications

Hybrid Anti-Islanding Algorithm for Utility Interconnection of Distributed Generation

Comparison of Adaptive Neuro-Fuzzy based PSS and SSSC Controllers for Enhancing Power System Oscillation Damping

International Journal of Scientific & Engineering Research, Volume 7, Issue 12, December-2016 ISSN Ribin MOHEMMED, Abdulkadir CAKIR

HVDC CAPACITOR COMMUTATED CONVERTERS IN WEAK NETWORKS GUNNAR PERSSON, VICTOR F LESCALE, ALF PERSSON ABB AB, HVDC SWEDEN

Keeping it up to Speed Off-Nominal Frequency Operations. CETAC 2018 San Ramon

Power Plant and Transmission System Protection Coordination Fundamentals

NPCC Regional Reliability Reference Directory # 12. Underfrequency Load Shedding Program Requirements

Power System Stability Enhancement Using Static Synchronous Series Compensator (SSSC)

TRANSIENT STABILITY ENHANCEMENT OF POWER SYSTEM USING INTELLIGENT TECHNIQUE

An Adaptive Protection Scheme for Optimal Overcurrent Relay Coordination in Interconnected Power Systems

Reducing the Effects of Short Circuit Faults on Sensitive Loads in Distribution Systems

Fuzzy Approach to Critical Bus Ranking under Normal and Line Outage Contingencies

Power System Load Shedding: Key Issues and New Perspectives

Massive Transient Stability Based Cascading Analysis and On-line Identification of Critical Cascades

Power System Reliability and Transfer Capability Improvement by VSC- HVDC (HVDC Light )

Reliability Guideline: Generating Unit Operations During Complete Loss of Communications

Identification of weak buses using Voltage Stability Indicator and its voltage profile improvement by using DSTATCOM in radial distribution systems

POWER systems are being operated closer to the stability

Grid codes and wind farm interconnections CNY Engineering Expo. Syracuse, NY November 13, 2017

CHAPTER 4 PV-UPQC BASED HARMONICS REDUCTION IN POWER DISTRIBUTION SYSTEMS

New Techniques for the Prevention of Power System Collapse

P5 Policy 5: Emergency Operations

Advantages and Disadvantages of EHV Automatic Reclosing

Transmission System Phase Backup Protection

FUZZY BASED SMART LOAD PRIMARY FREQUENCY CONTROL CONTRIBUTION USING REACTIVE COMPENSATION

Hydro-Québec s Defense Plan: Present and Future

AUTOMATIC GENERATION CONTROL OF REHEAT THERMAL GENERATING UNIT THROUGH CONVENTIONAL AND INTELLIGENT TECHNIQUE

Analysis of Effect on Transient Stability of Interconnected Power System by Introduction of HVDC Link.

Journal of Engineering Technology

Wide-Area Measurements to Improve System Models and System Operation

Reduction of Voltage Imbalance in a Two Feeder Distribution System Using Iupqc

Doãn Văn Đông, College of technology _ Danang University. 2. Local Techniques a. Passive Techniques

POWER TRANSFORMER PROTECTION USING ANN, FUZZY SYSTEM AND CLARKE S TRANSFORM

System Protection Schemes in Power Network based on New Principles

Eliminating Power Transients When Switching Large Motors or Transformers during Power Outages or Engine Testing

Considerations and Recommendations for the Harmonisation of Under Frequency Loadshedding Schemes in Multi Zone Meshed Grids

Fuel cell power system connection. Dynamics and Control of Distributed Power Systems. DC storage. DC/DC boost converter (1)

A Novel Approach for Reducing Proximity to Voltage Instability of Multibus Power System with Line Outage Using Shunt Compensation and Modal Analysis

A New Hybrid Approach to Thevenin Equivalent Estimation for Voltage Stability Monitoring

A.V.Sudhakara Reddy 1, M. Ramasekhara Reddy 2, Dr. M. Vijaya Kumar 3

Identification of Critical Bus and Optimal Allocation of Facts Device

GridLiance Reliability Criteria

Wind Power Facility Technical Requirements CHANGE HISTORY

each time the Frequency is above 51Hz. Continuous operation is required

Recently, the SS38 Working Group on Inter-Area Dynamic Analysis completed two study reports on behalf of the UFLS Regional Standard Drafting Team.

VOLTAGE SAG COMPENSATION USING UNIFIED POWER FLOWER CONTROLLER IN MV POWER SYSTEM USING FUZZY CONTROLLER

PRC Generator Relay Loadability. A. Introduction 1. Title: Generator Relay Loadability 2. Number: PRC-025-1

Automatic Voltage Control For Power System Stability Using Pid And Fuzzy Logic Controller

Thyristor Based Static Transfer Switch: Theory, Modeling and Analysis

NERC / TVA STABILITY WORKSHOP

Design of Interline Dynamic Voltage Restorer for Voltage Sag Compensation

Transcription:

INTERNATIONAL JOURNAL OF COMPUTER ENGINEERING & TECHNOLOGY (IJCET) International Journal of Computer Engineering and Technology (IJCET), ISSN 0976 6367(Print), ISSN 0976 6367(Print) ISSN 0976 6375(Online) Volume 3, Issue 2, July- September (2012), pp. 389-398 IAEME: www.iaeme.com/ijcet.html Journal Impact Factor (2012): 3.9580 (Calculated by GISI) www.jifactor.com IJCET I A E M E UNDER FREQUENCY LOAD SHEDDING FOR REDUCTION OF ENERGY LOSS USING BY ADAPTIVE NEURO FUZZY TECHNIQUE M.S.Sujatha Manoj Kumar.N Dr M. Vijay Kumar Dept.of EEE Dept.of EEE Professor in Dept.of EEE S.V.C.E S.V.C.E JNTUCA A.Rangampet, Tirupathi. A.P A.Rangampet, Tirupathi, A.P Anantapur, A.P, India sujatha.machineni@gmail.com manojkumar.neela@gmail.com ABSTRACT Electricity is regarded as one of the indispensable means to growth of any countries economy. The main objective of any generation and distribution utility is to satisfy the demand of customers with a high quality product. To ensure this quality, the voltage and frequency should be constant during normal operation and uninterrupted service requirement should be satisfied. In power system, blackouts have been the most problem occur in the interconnected grid, which results in large loss. In recent years this phenomenon has considerably increased based on the frequency and the severity of this problem. Some kind of operation contributes to the recently occurred blackouts such as incorrect of protective systems, voltage instability, and lack of under frequency load shedding. Under frequency load shedding (UFLS) scheme is proposed to enhance the reliability of power systems to against system failure and fault occur. Speed and accuracy of under frequency load shedding (UFLS) has a vital role in its effectiveness for preserving system stability and reducing energy loss. Initial rate of change of frequency is a fast and potentially useful signal to detect the overload when a disturbance happens. In order to improve the under-frequency load shedding performance, a global load shedding scheme with rate of frequency decline is proposed. This paper presents a new method for solving under frequency load shedding (UFLS) problem by using neural network and fuzzy logic controller. It also presents fast and accurate load shedding technique based on adaptive neuro-fuzzy controller for determining the amount of load shed to avoid a cascading outage. The development of new and accurate techniques for vulnerability control of power systems can provide tools for improving the reliability, continuity of power supply and reducing energy loss. Keywords: Load shedding, Under Frequency, Rate of frequency decline, Ada ptive Neuro-Fuzzy, fuzzy Controller, Nero-Fuzzy, Power system, Vulnerability control. I.INTRODUCTION The electric power system is a complex system, whose operating condition may not remain at a constant value. This necessitates the power system operator be alert to keep the system performance under normal condition. The various contingencies like, large load 389

variations, outage of components (transmission lines, transformers, generators, etc.) are more common. One of the major challenges of electric utilities in recent years is power system blackout. For instance the blackouts of Greece, Italy, North America, Sweden and Denmark, Iran and many others have been mentioned in the literature [1]-[5]. In fact, due to both economical and technological restrictions, it is not possible to completely prevent these blackouts. However, with the aid of some protection and control strategies, frequency and severity of these blackouts may be reduced [6]. One of the important protection strategies used for this purpose is a class of protection schemes known as System Protection Schemes [7], [8]. System protection schemes are protection strategies designed to detect a particular system condition that is known to cause unusual stress to the power system, and to take some kind of predetermined action to counteract the observed condition in a controlled manner [9]. One of the most commonly used types of system protection schemes, generally accepted after the northeastern blackout of 1965, is Under Frequency Load Shedding (UFLS) scheme [10]. Conventional UFLS system is designed to recover the balance of generation and consumption following a generator outage or sudden load increase. The loads to be shed by this system are constant load feeders and are not selected adaptively. In other words always the same loads are dropped from the system, regardless of the location of disturbance. In this method loads are classified in three groups of non-vital, semi vital and vital loads [11]. The trend is to shed non-vital loads. However in severe conditions semi-vital loads may also be shed. Obviously this constant non-adaptive load shed scheme is not the most efficient one and may cause some problems in the system. As an example, outage of a major generating unit in the power system may cause transfer of high amount of power in long distances which can reduce voltage stability margin of the system. In this situation occurrence of another contingency may cause voltage instability, though the system is stable in terms of frequency. After occurrence of the system disturbance, frequency initially decreases and then it might return back to its near normal value, but system might become unstable due to voltage problem. The return of frequency is due to load dependency on voltage and frequency. Therefore, modeling the dependency of load upon voltage and frequency is of essential importance. In this research work this dependency is considered using appropriate load models. Conventional UFLS schemes are generally implemented in a decentralized, i.e. distributed protection system. In this approach the decision to shed load is made using the local frequencies measured at the location of relays. However, in recent years, application of centralized load shedding algorithms to enhance adaptability of the schemes has been proposed in some publications [12]. This paper is organized as follows: Section-II gives the introduction to load shedding; conventional load shedding methods are discussed in section-iii, proposed method is discussed in section-iv it also gives the mathematical analysis of shedding, Section-V gives the simulation results and comparison of different methods, finally we will conclude our work in Section-VI. II. LOAD SHEDDING As already mentioned, when a power system disruption creates a large generation load imbalance, resulting in a frequency decline, emergency action such as under frequency load shedding may be needed. If system frequency reaches a given threshold, even for a short amount of time, power stations may trip off resulting in further load imbalance which may lead to a global system collapse. 390

When there is a rapid decline in frequency, simple governor response may be neither sufficient nor quick enough to stop the frequency excursion before it reaches the protection threshold of frequency relays in other power plants. Thus, there is a need for a complementary emergency action in order to assure that the declining frequency is stopped before reaching this threshold. III. CONVENTIONAL LOAD SHEDDING APPROACH This section is a review of load shedding techniques that have been devised over a number of years each having its own set of applications and drawbacks. A. Breaker Interlock Load Shedding This is the simplest method of carrying out load shedding. For this scheme, the circuit breaker Interdependencies are arranged to operate based on hardwired trip signals from an intertie circuit breaker or a generator trip. This method is often used when the speed of the load shedding is critical. Even though, the execution of this scheme is fast, breaker interlock load shedding possesses a number of inherent. Drawbacks: Load shedding based on worst-case scenario Only one stage of load shedding Almost always, more loads is shed than required Modifications to the system are costly B. Under-Frequency Relay (81) Load Shedding Guidelines for setting up a frequency load shedding are common to both large and small systems. The design methodology considers fixed load reduction at fixed system frequency levels. Upon reaching the frequency set point and expiration of pre-specified time delay, the frequency relay trips one or more load breakers. This cycle is repeated until the system frequency is recovered, e.g., 10% load reduction for every 0.5% frequency reduction. Since this method of load shedding can be totally independent of the system dynamics, total loss of the system is an assumed possibility. Additional drawbacks of this scheme are described below. Slow response time. Incorrect / excessive load shedding Analysis knowledge is always lost C. Programmable Logic Controller-Based Load Shedding With Programmable Logic Controller (PLC) scheme, load shedding is initiated based on the total load versus the number of generators online and/or detection of under-frequency conditions. Each substation PLC is programmed to initiate a trip signal to the appropriate feeder breakers to shed a preset sequence of loads. This static sequence is continued until the frequency returns to a normal, stable level. A PLC-based load shedding scheme offers many advantages such as the use of a distributed network via the power management system, as well as an automated means of load relief. However, in such applications monitoring of the power system is limited to a portion of the network with the acquisition of scattered data. This drawback is further compounded by the 391

implementation of pre-defined load priority tables at the PLC level that are executed sequentially to curtail blocks of load regardless of the dynamic changes in the system loading, generation, or operating configuration. The system-wide operating condition is often missing from the decisionmaking process resulting in insufficient or excessive load shedding. In addition, response time (time between the detection of the need for load shedding and action by the circuit breakers) during transient disturbances is often too long requiring even more load to be dropped. IV PROPOSED SYSTEM A. Mathematical analysis of load shedding: 1) Active Power and Frequency During normal operation of power system, the total mechanical power input to the system generators is equal to the sum of the connected loads plus all real power losses [13]. If for any reason, the balance of Generation and loads is disrupted, operating frequency of the system would change according to (1). 2 H = Pm Pe (1) Where H is the inertia constant f is the generator frequency in pu P m is the generator mechanical power in pu P e is the generator electrical power in pu In general, power system loads are dependent on both voltage and frequency. To be able to compute exact amount of system load, this dependence should be considered. Power system voltage is a local parameter and its value is not usually known precisely for each remote system bus. As such, the effect of voltage in load modeling has been ignored in several researches. Despite of voltage, system frequency is a general parameter and is almost similar at all points of a power system [14]. The frequency dependent characteristic of composite load may be expressed as (2): P e = P L + d f (2) Where d is load reduction factor P L is the load power in Pu 2) Final Frequency According to (1) and (2) if a power system encounters with an overload case, then frequency of the system begins to decline. At the same time, system load which is dependent on frequency by factor d is reduced as well. If no other action is performed, eventually system settles at a final frequency at which the amount of generation reduction would be equal to reduction of system loads [13]. P m = d P e (3) The final frequency will be: Where f is the initial frequency f is the final frequency lo is the amount of overload in pu 3) Minimum Allowable Frequency f =fo 1 (4) 392

All of the power system apparatus are made and designed for nominal frequency. Power plant auxiliary services are more demanding in terms of minimum allowable frequency. Steam turbine is the most sensitive equipment against frequency drops. Continues operation of steam turbines should be restricted to frequency above 47.5 Hz. Frequency falls below 47 Hz must be avoided. In fact, every commercial turbine can sustain up to 10 contingencies at 47 Hz just for one second without being jeopardize [4]. 4) Load Amount to be shed For a system overload the amount of load which must be shed is determined based on the minimum allowable frequency and the amount of overload. The minimum allowable frequency could be considered as 47 Hz instead of 47.5 Hz in load shedding schemes design, if the system dispatch center can increase the generation by governors quickly. Total amount of the load which must be shed to cover the maximum anticipated overload, is obtained from [5] LD= Where LD is total load which must be shed f is permissible settling frequency (5) B. Fuzzy Logic The implemented expert system has the following components is shown in Figure 1. Figure 1: Block diagram of Fuzzy Inference System Fuzzifier The given Input values are converted to fuzzy valves for ease of access the input data. Here the input for the interference engine is Rate of change of frequency. Inference Engine Is that part of the expert system that is responsible for decision-making, using rules chaining. Chaining is either forward or backward. Forward chaining is used when there is no exact goal to search for, also if the initial states are less than the goal states. On the other hand, backward chaining is used when there is an exact solution to search for and it is required to find the path to this goal, also it is used when the number of final states is less than the initial states. Decisions Based on the obtained input from the controller the fuzzy controller decides the output based on the membership function we already given in its knowledge base. 393

Load Shedding Using Fuzzy Controller In this paper the generation and load data are given as inputs to the simulation system shown in fig 3, it calculates the rate of change of frequency at that moment and sends that data to the fuzzy controller. The fuzzy controller decides the amount of load shed required to maintain the system to operate in stable manner. C. Neuro-Fuzzy Neuro-fuzzy system is a combination of neural network and fuzzy logic in which it combines the learning and adapting abilities of neural networks with the fuzzy interpretation of fuzzy logic system. An example of a neuro-fuzzy system is the adaptive neural network based fuzzy inference system (ANFIS) which combines the Takagi Sugeno fuzzy inference system (FIS) with neural network. The ANFIS defines five layers which perform the function of fuzzification of the input values, aggregation of membership degree, evaluation of the bases, normalization of the aggregated membership degree and evaluation of function output values. A typical ANFIS structure with five layers and two inputs, each with two membership functions is shown in Fig 2. The five layers of the ANFIS are connected by weights. The first layer is the input layer which receives input data that are mapped into membership functions so as to determine the membership of a given input. The second layer of neurons represents association between input and output, by means of fuzzy rules. In the third layer, the output are normalized and then passed to the fourth layer. The output data are mapped in the fourth layer to give output membership function based on the pre-determined fuzzy rules. The outputs are summed in the fifth layer to give a single valued output. The ANFIS has the constraint that it only supports the Sugeno-type systems of first or 0th order. The system can only be designed as a single output system and the system must be of unity weights for each rule. Figure 2: ANFIS Structure with 1 input, 1 Output, and 1 Membership Function for each input Load Shedding Using Neuro-Fuzzy Controller Fuzzy logic system needs rules to be defined first, but one may have no knowledge about a power system for the formation of rules. Therefore, automated parameters tuned by a neural network embedded inside a fuzzy system can replace the need for prior knowledge about a power system. To implement the proposed load shedding scheme for vulnerability control of power systems, firstly, base case simulation is carried out on a power system so as to analyze the system behavior at the base case condition. The next step is to analyze the system behavior when subjected to credible system contingencies such as line outage (LO), generator outage (GO), load increase (LI) and disconnection of loads (DL). The selection of inputs to the controller is an 394

important design consideration and therefore for power system vulnerability control, the Rate of change of frequency is selected as input variables for the load shedding controllers. The overall output of the ANFIS is the estimated amount of load shed. In this paper Rate of change of frequency is given as input for the Neuro-Fuzzy controller and the output obtained is the amount of load is required to shed in order to maintain the system in a stable manner. Here the training data is given which was collected from the Electricity Board and error is observed. V. SIMULATION RESULTS Figure 3: simulation diagram of Fuzzy Controlled Load Shedding df/dt Actual output value Fuzzy output value -0.4 160 152-1.3 520 503-1.9 760 728-2.5 1000 960 Table 1: comparison of actual output value with Fuzzy output value 395

Figure 4: variation of Frequency when load is more than generation and restoration Generation Load df/dt Actual difference Fuzzy output value 10000 9500 0.8355 500 0 10000 10000 0 0 0 10000 10500-0.8355-500 322.9 10000 11234-2.04-1234 793.7 11000 10000 1.515 1000 0 11000 11234-0.3536-234 137.7 11000 12345-2.308-1345 786.4 Table 2: Output Values of Fuzzy controller Figure 5: Results of the fuzzy controller 396

Figure 6: Training Error of Neuro-fuzzy controller df /dt Actual output value Neuro- Fuzzy output value Fuzzy output value -.3 120 123 119 -.9 360 357 344-1.4 560 554 536-1.8 720 717 695-2.6 1040 1042 1000 Table 3: Comparison of Actual, neural and Fuzzy Output Values Table.1 shows the output values of fuzzy controller based on its Rate of change of frequency. Table.2 shows the inputs of the Fuzzy controller (Generation and Load) by that it calculates the Rate of change of Frequency (df/dt) and the output obtained is the amount of load shed required to maintain the system to operate in a stable manner. Table.3 shows comparison of Actual, Neuro-Fuzzy and Fuzzy output values. VI. CONCLUSIONS In power system, blackouts have been the most problem occur in the interconnected grid which results in large loss. In recent years this phenomenon has considerably increased based on the frequency and the severity of this problem. Under frequency load shedding (UFLS) scheme is proposed to enhance the reliability of power systems against system failure and fault occur. A new load shedding scheme is developed by means of using neuro-fuzzy controller to determine the optimal amount of load to be shed so that a power system can remain in a secure condition. The neuro-fuzzy load shedding technique combines the use of fuzzy logic and neural network techniques. The performance of the proposed neuro-fuzzy load shedding is validated. The proposed neuro-fuzzy technique has proven to be a more effective method in determining the optimal value of load shed in which the average absolute error for the neuro fuzzy technique within tolerable limits. It is also demonstrated to be a useful load shedding tool for providing fast vulnerability control. By this method we can avoid the unnecessary load shedding and reduce the energy loss. 397

REFERENCES [1] C. Vournas, Technical summary on the Athens and southern Greece blackout of July 12, 2004 ", National Technical University of Athens Report [2] S. Corsi, C. Sabelli, " General blackout in Italy, Sunday September 28, 2003, h. 03:28:00 ", IEEE Power Engineering Society General meeting, 2004, Vol. 2, Pages 1691-1702, [3] " Power failure in eastern Denmark and southern Sweden on 23 September 2003, Final report on the course of events ", Elkraft System, November 2003 [4] " Technical analysis of the August 14, 2003 blackout, What happened, why and what did we learn? ", North American Electric Reliability Council, Final Report, July 23, 2004 [5] M. Sanaye Pasand, M. R. Dadashzadeh, Iran national grid blackout, power system protection point of view ", Developments in Power System Protection, 8 th IEE International Conf. April 2004, Vol. 1, Pages 20-23 [6] S. H. Horowitz, A. G. Phadke, Boosting immunity to blackouts ", IEEE Power and Energy Magazine, Sept. /Oct. 2003 [7] S. Tamronglak, S. H. Horowitz, A. G. Phadke, J. S. Thorp, " Anatomy of power system blackouts: preventive relaying strategies ", IEEE Trans. on Power Delivery, vol. 11, No. 2, April 1996 [8] M. Jonson, " Protection strategies to mitigate major power system breakdowns ", Ph.D. Dissertation, Chalmers University of Technology, Goteborg, Sweden, 2003 [9] P. Crossley, F. Ilar, D. Karlsson, " System protection schemes in power networks: existing installations and ideas for future development ", Developments in power system protection conference, No. 479, IEE 2001 [10] C. W. Taylor, Concepts of under voltage load shedding for voltage stability ", IEEE Trans. on Power Delivery, vol. 7, No. 2, April. 1992 [11] Z. Ding, D. Cartes and S. Sirvastava, " New load shedding scheme for islanded power systems ", 2006 IEEE/SMC International Conference on System of Systems Engineering Los Angeles, CA, USA - April 2006 [12] V. V. Terzija, " Adaptive under frequency load shedding based on the magnitude of the disturbance estimation ", IEEE Transactions on Power Systems, Vol. 21, No. 3, Aug. 2006 [13] J. R. Jones and W.D. Kirkland, "Computer algorithm for selection of frequency relays for load shedding," IEEE Computer Application in Power, pp. 21-25, Jan. 1988. [14] M. NagpaI, A. Moshref, Z. Shukn,.I. T. Vijayan, D. Chan and C. Henvile "Dynamic simulation optimize application of an under frequency load shedding scheme," Western Protective Relay Conference, Spokane, Washington, October 2 1-23, 1997. AUTHORS BIBILOGRAPHY: M.S. Sujatha is currently pursuing her PhD degree in Electrical and Electronics Engineering department at university of JNTUCA, Anantapur, A.P, India. She received her B.E degree from Mysore University and M.Tech degree from JNTUCA, Anantapur. Her research interest includes wireless technologies for power system applications; protection, monitoring and control and reduction in Energy Losses. Manoj Kumar.N is currently pursuing his M.Tech at Sree Vidyanikethan Engineering college, Tirupati, affiliated to JNTUCA. He completed his B.Tech at N.B.K.R. Institute of Science and Technology, Vidyanagar, A.P, India in the year 2010. Dr. M. Vijay Kumar Graduated from NBKR Institute of Science and Technology, Vidyanagar, A.P, India in 1988.He obtained M.Tech degree from Regional Engineering College, Warangal, India in 1990. He received Doctoral degree from JNT University, Hyderabad, India in 2000. He has guided 10 PhD s. Currently, he is Professor in Electrical and Electronics Engineering Department at JNTUA, Anantapur A.P, India. His areas of research interest are power system protection, monitoring, control, power electronic and drives and power quality issues. He is the recipient of The Pandit Madan Mohan Malaviya Memorial Prize. 398