GSM Based Wireless Load-Shedding Management System for Non Emergency Condition

Similar documents
Wireless Distributed Load-Shedding Management System for Non-Emergency Cases

DISTRIBUTION TRANSFORMER MONITORING AND CONTROL SYSTEM FOR REMOTE ELECTRIC POWER GRIDS THROUGH GSM

Cortex-M3 based Prepaid System with Electricity Theft Control

Monitoring the Transformer Oil Temperature and Load Sharing Using Gsm

Feeder Protection From Over Load and Earth Fault Relay

Energy Meter Tempering and Power Tapping Detection System for Effective Power Theft Control


Smart Monitoring and Power Factor Correction of Distribution Transformer using IOT

Design and Implementation of Smart Car Driving Kulkarni S.D.

Automated E-Billing and Supply Control using Power Line Communication

Automatic Load Sharing of Transformers using Microcontroller

Modern Electricity Billing System and Fuse Detection Using GSM

Design and Development of Pre-paid electricity billing using Raspberry Pi2

Monitoring and Protection of Distribution Transformer Using GSM Module Jenifer A 1, Bharathi B R 2, Shanthi Mounika B 3

MONITORING OF DISTRIBUTION TRANSFORMER PARAMETERS USING PLC

Keyword: - GSM kit, Transformer, sensors, rectifier, microcontroller, power supply, LCD.. Vol-3 Issue INTRODUCTION

Substation Monitoring System

Mobile Agent Based Intelligence Power Distribution Control System

GSM Based Automated Embedded System for Monitoring and Controlling of Smart Grid

GSM BASED TRANSFORMER HEALTH MONITORING SYSTEM

AUTOMATIC POWER FACTOR CORRECTION AND MONITORING BY USING PIC MICROCONTROLLER

LABORATORY AND FIELD INVESTIGATIONS ON XBEE MODULE AND ITS EFFECTIVENESS FOR TRANSMISSION OF SLOPE MONITORING DATA IN MINES

Real Time AMR & Control of Household Energy Meter with Zigbee communication

IMPLEMENTATION OF EMBEDDED SYSTEM FOR INDUSTRIAL AUTOMATION

International Journal of Electronics and Communication Engineering & Technology (IJECET), ISSN COMMUNICATION ENGINEERING & TECHNOLOGY (IJECET)

Cortex-M3 based Prepaid System with Electricity Theft Control

International Journal of Modern Trends in Engineering and Research GSM based fault alert system for BTS (Mobile tower)

HUMAN BODY MONITORING SYSTEM USING WSN WITH GSM AND GPS

International Journal of Modern Trends in Engineering and Research e-issn No.: , Date: April, 2016

GPS and GSM Based Transmission Line Monitoring System with Fault Detection Introduction:

A Wireless Smart Sensor Network for Flood Management Optimization

I. INTRODUCTION II. LITERATURE REVIEW

International Journal Of Engineering Research & Management Technology

WIRELESS RF TRANSCEIVER FOR ENERGY METER READING SYSTEM

II. LITERATURE SURVEY

Soldier Tracking and Health Indication System Using ARM7 LPC-2148

Wavelet Based Analysis of Online Monitoring of Electrical Power by Mobile Technology

Theft Intimation of Electrical Power over SMS

An Automated Rainfall Monitoring System

INNOVATIVE ENERGY METER WITH LOAD CONTROL BHARATHY R 1, JHANANI SHREE U 1 and ANITHAMARY M 1 1 Assistant Professor

Simulation Of Radar With Ultrasonic Sensors

Design and Implementation of Loss Reduction of Transmission and Distribution Line Using GSM Technology and ZIGBEE

Wireless Speed Control of an Induction Motor Using Pwm Technique with Gsm

GSM Based Water Billing System

Simulation & Realization of Feeder Protection with Micro Controller

II. BLOCK

ARM BASED DISTRIBUTED ELECTRICITY MONITORING AND CONTROL USING GSM MODEM

A Review of Adaptive Under Frequency Load Shedding Scheme on Islanded Distribution System Using MATLAB/SIMULINK

AUTOMATIC ELECTRICITY METER READING AND REPORTING SYSTEM

Implementation of Automatic meter reading system using zigbee- Integrated Raspberry Pi,GSM Network

Design of WSN for Environmental Monitoring Using IoT Application

Transformer Health Condition Monitoring Through GSM Technology

Hamdy Faramawy Senior Application Specialist ABB Sweden

Sensor based Automated Irrigation System with IOT

DISTRIBUTION LINE FAULT DETECTION AND INTIMATION USING GSM

DESIGN ANALYSIS AND REALIZATION OF MICROCONTROLLER BASED OVER CURRENT RELAY WITH IDMT CHARACTERISTICS: A PROTEUS SIMULATION

Design and Development of Smart. Harmonic Analyzer

Design of a prototype to detect mobile phone usage in restricted areas

Real Time Transformer Health Monitoring System using IOT

Management of Home Appliances with Variation in Environment Aisha Jilani, Sahar Sultan, Intesar Ahmed and Sajjad Rabbani

International Journal of Modern Trends in Engineering and Research e-issn No.: , Date: April, 2016

Design and Implementation of AT Mega 328 microcontroller based firing control for a tri-phase thyristor control rectifier

Aztec Micro-grid Power System

WIRELESS THREE PHASE LINE FAULT MONITORING

Monthly Electricity Billing via SMS using GSM

High Impedance Fault Detection and Location in a Power Transmission Line Using ZIGBEE

Intelligent Bus Tracking and Implementation in FPGA

ISSN (PRINT): , (ONLINE): , VOLUME-4, ISSUE-1,

Advanced Soldier Monitoring and Tracking System Using GPS and GSM Introduction

REACTIVE POWER COMPENSATION IN DISTRIBUTION SYSTEM

Design of Low Cost Embedded Power Plant Relay Testing Unit

Design and implementation of GSM based and PID assisted speed control of DC motor

Design and Development of Train Tracking System in South Central Railways

PIONEER RESEARCH & DEVELOPMENT GROUP

Improve asset protection and utilization

Design and Implementation of Integrated Smart Township

The modular system for communication, alerting and people search

Design Of Low-Power Wireless Communication System Based On MSP430 Introduction:

Vehicle accident messenger system

(

AMI (ADVANCED METERING INFRASTRUCTURE) MESH WITHOUT SWITCHES IN THE KIT SECTION

International Journal of Scientific Research and Reviews

AUTOMATED WATER METER READING

International Journal of Advance Engineering and Research Development AUTOMATIC METER READING FOR ELECTRIC BOARD USING RF (RADIO FREQUENCY)

AUTOMATIC RAILWAY CROSSING SYSTEM

[Ahmed, 3(1): January, 2014] ISSN: Impact Factor: 1.852

SCIENCE & TECHNOLOGY

IN ELECTRICAL ENGINEERING - I C M E T CRAIOVA

GSM BASED ENERGY THEFT MONITORING SYSTEM

Four Quadrant Speed Control of DC Motor with the Help of AT89S52 Microcontroller

VVVF POWER SOURCE USING SPWM

International Journal of Advance Engineering and Research Development

Real Time Traffic Light Control System Using Image Processing

International Journal of Advance Engineering and Research Development

Solutions. Remotek's Advantages

ATB200. Datasheet. ATB200 GPRS / GPS based Fleet Management Terminal. 1

Power Line Communication Based Fault Monitoring And Control

Soil Moisture Control Using RF Transreceiver

INTELLIGENT AUTOMATIC STREET-LIGHTING SYSTEM WITH ADVANCE CONTROL THROUGH GSM MODEM

International Journal of Scientific & Engineering Research Volume 8, Issue 7, July-2017 ISSN

Transcription:

e-issn: 2349-9745 p-issn: 2393-8161 Scientific Journal Impact Factor (SJIF): 1.711 International Journal of Modern Trends in Engineering and Research www.ijmter.com GSM Based Wireless Load-Shedding Management System for Non Emergency Condition Patil P T 1, Dattatraya raut 2, Sagar Sutar 3, Sandesh Narute 4 1 Departmentof Electrical, SBPCOE 2 Department of Electrical, SBPCOE 3 Department of Electrical, SBPCOE 4 Department of Electrical, SBPCOE Abstract In that papers, most of us current a new cost-effective wireless allocated fill shedding technique for non-emergency scenarios. Throughout electric power transformer destinations wherever SCADA technique can't be utilized, your suggested remedy offers a realistic choice that will includes the usage of microcontrollers as well as recent GSM commercial infrastructure in order to deliver first alert SMS communications in order to customers counseling them to proactively lessen their particular electric power usage prior to technique capacity can be attained as well as stepby-step electric power shutdown takes place. Some sort of story verbal exchanges process as well as message arranged are invented to deal with your messaging between the transformer web sites, the spot that the microcontrollers are situated as well as the spot that the sizes occur, as well as the key control web page the spot that the repository server can be organized. Furthermore, the machine posts alert communications towards the end-users mobile products which have been utilized since verbal exchanges terminals. The system has become put in place as well as tried by using distinct experimental effects. Keywords-Smart Grid, Load shedding, Demand Side Management, GSM Wireless Networks, SCADA systems. I. INTRODUCTION India is experiencing an unprecedented increase in electricity consumption. A direct consequence of these increase demand is the enormous load burden that has been imposed on the national electricity grid, especially during peak demand periods. One solution to this problem would be lode shedding is a process in which electric power is cutoff on certain lines of power transformers when the demand approaches the system capacity. Load shedding is particularly important in isolated systems (islands of service) since there is no interconnected supply of power if the demand exceeds the power rating of the transformers. Typically load shedding is done by supervisory and monitoring systems such as supervisory control and data acquisition systems known as SCADA systems which continuously monitor vital parameters of the power system and decide when and how much load to shed. SCADA systems usually shed the appropriate power load keeping a well-balanced system and at the same time maintaining reasonable customer satisfaction. In a typical load-shedding scheme a list of loads is used during the shedding process depending on a priority level attributed to the various customer loads. When there is an excessive load on the transformers, the SCADA system starts shedding the lowest priority load.[7] This method of shedding is acceptable as long as the transformers are monitored by the central SCADA system. Remotely-located transformers, lacking SCADA connection cannot benefit from this scheme. Such transformers should have their own protection mechanisms for handling emergencies [1-3]. Load shedding in general has been studied extensively in the literature and adaptive strategies for Emergency Load-Shedding (ELS) circumstances in isolated systems, in particular, are studied in detail in [4-6]. In this paper we present a novel wireless-distributed load shedding management system which is designed to handle remotely distributed transformers that are not connected to a SCADA system. The proposed system is designed for nonemergency cases and proactively involves users in the shedding process. Systems

International Journal of Modern Trends in Engineering and Research (IJMTER) Volume 02, Issue 01, [January - 2015] e-issn: 2349-9745, p-issn: 2393-8161 located in a hot climate zone, such as the emirates of Sharjah and Dubai of the United Arab Emirates, have many remotely-distributed transformers throughout the coverage area. During hot days, the peak power consumption is significantly higher than normal loads. Even though the power grid is designed to handle such peak loads, it is possible that spurious excessive demand may cause power shutdown. II.LITERATURE SURVEY Power need within Maharashtra have been rising at a very high price within the last 24 months. With 2004-05, the high need went up by 11357 MW to 12749 MW around 2003-04which is a leap associated with 12. 26per when compared with before regular increase associated with 2. 74per. As the need have been increasing, the age group potential has always been stable together with maximum option of 9300 MW. This particular experienced ended in some sort of high hole associated with 3449 MW within 2004-05.With 2005-06, the high need recorded within May well 05 was 12987 MW and that is once more some sort of leap associated with 238 MW in the earlier yr. This particular experienced ended in some sort of shortage (load shedding)of 3687 MW within May well 05. Inside the thirty day period associated with Oct 05, the high evening need that experienced decrease to 10, 000 MW within September has within the last twenty times risen to 12, 200MW. This is a leap associated with 2, 250 MW inside a amount of 7 to 8 times. Past this can be a feature Mumbai during which Tata Electrical power had been attracting MSEDCL's strength within high time increasing weight losing within MSEDCL's areas. Thinking about the increase sought after, the existing debt associated with 3500 -- four thousand MW could possibly rise to 10, 000 MW by means of 2012-13 in the event endeavors are not built to increase availableness. Electrical power is definitely a vital part inside the fiscal increase of your Express. As per the Economists, the investment associated with Rs. 1 Cr. inside the strength sector ends up with some sort of Rs. 20 Cr. Progress throughout the market. MSEDCL is additionally trying to take care of the need via Desire Aspect Supervision Procedures. III. SYSTEM ARCHITECTURE Fig3.1Block diagram of system In above system, consumer energy consumption is continuously monitored by current transformer. This output from CT is given to signal conditioner, so that it can be made compatible with microcontroller input. This input is compared with max. Limit allocated to the customer. This comparison is done only at pick time of energy consumption like 6 P.M to10 P.M. If consumer uses more energy then set limit, then initially he gets warning messages to user still if he didn't reduce power consumption then energy supply is cutout by means of relay. @IJMTER-2014,All rights Reserved 595

International Journal of Modern Trends in Engineering and Research (IJMTER) Volume 02, Issue 01, [January - 2015] e-issn: 2349-9745, p-issn: 2393-8161 IV. FLOW CHART Fig3.2 System flow architecture V. HARDWARE DESCRIPTION Current Transformer, Rectifier Filter and Circuit: Here current transformer is used to step down the load current.this recent is actually and then transferred over the fill rectifier circuit filtering. Circuit to get the voltage in terms of load Current. Then it is given to the scaling amplifier, buffer and unity gain amplifier. Scaling Amplifier, Buffer and Unity Gain Amplifier: The scaling amplifier is used to provide the necessary scaling gain for the rectified Signal. The unity gain amp is used in order to isolate reduce the burden (loading effect) toprevious stage. Then the output is given to the serial ADC. Analog to Digital Converter: ADC used here is serial ADC. It converts the analog information to digital data. This digital data is given to the micro-controller. Microcontroller: Here, micro-controller will take the data from serial ADC and it will transmit tothe pc. Then microcontroller will wait to receive data from pc. If the received data willcompared with stored per- @IJMTER-2014,All rights Reserved 596

International Journal of Modern Trends in Engineering and Research (IJMTER) Volume 02, Issue 01, [January - 2015] e-issn: 2349-9745, p-issn: 2393-8161 defined value result is send back to the micro-controller. Then System Development micro-controller gives signal to the relay. Relay Driver Circuit: It is used to drive the relays. Micro-controller gives the signal to the relay drivercircuit to drive the relay so the heavy load equipment s will be turned on or off. Buzzer: Whenever overload condition occurs the buzzer will start. VI. SOFTWARE DESCRIPTION The software was designed in Assembly Language. The microcontroller is a programmable chip, which needs to be programmed to perform the desired functions (Yelaran and Emery, 2010).The source code was first compiled on the notepad.proper attention was paid to the code during compilation so as to avoid any form of logical and syntax error. The generated hex file after compilation was then transferring to the microcontroller chip with the aid of an EDSIMprogrammer. VII. GSM MODEM INTERFACE UNIT The GSM modem(samsung G5282) was used to perform communication between the user and microcontroller. This is responsible to do the bidirectional operation of sending an alert sms to user mobile about the current status of the load and sent command to microcontroller from user. These alerts sms sent to the user mobile that are already stored in the draft of the phone modem. Whenever the microcontroller triggers the transistor connecting to the GSM modem, it will either request for the SMS in the draft to be sent to the user or to put ON the GSM phone. REFERENCES [1]J.J. Ford, H. Bevrani, G. Ledwich, "Adaptive load shedding andregional protection, International Journal of Electrical Power & EnergySystems, Volume 31, Pages 611-618. Issue 10, November-December 2009 [2] F. Capitanescu, B. Otomega, H. Lefebvre, V. Sermanson, T. VanCutsem, Decentralized tap changer blocking and load sheddingagainst voltage instability: Prospective tests on the RTE system,electrical Power and Energy Systems, Vol 31, Issue 9, 2009, pp 570 576. [3] R. M. Maliszewski, R.D. Dunlop, and G. L. Wilson, Frequencyactuated load shedding and restoration Part I philosophy, IEEETransactions on Power Apparatus and Systems, vol. 90, no. 4, 1971, pp.1452 1459. [4] A. Saffarian, M. Sanaye-pasand, H. Asadi, Performance Investigationof New Combinational Load Shedding Schemes, Joint InternationalConference on Power System Technology and IEEE Power IndiaConference, 2008. pp 1 8. [5] A. A. Abou, A. Zein El-Din, S. R. Spea, S.R., Optimal load shedding n power systems, Eleventh International Middle East Power SystemsConference, Volume 2, 2006, pp. 568 575. [6] S. J. Huang, and C. -C. Huang, An adaptive load shedding method with time-based design for isolated power systems InternationalJournal of Electrical Power & Energy Systems, vol. 22, no. 1, January2000, pp. 51-58., January2000 [7]D. Rudrapalet. al. Automated Load SheddingPeriod Control Systems, International Journal oncomputer Sc. & Engineering, Vol 3, Issue 5, pp.1159-1168, May 2011. @IJMTER-2014,All rights Reserved 597