Suturing simplified. The first and only reusable, articulating, curved needle driver.

Similar documents
Suturing simplified. The first and only reusable, articulating, curved needle driver.

Minimally Invasive Suturing Devices

Dental Sutures. Japanese quality for best results.

Complete Sutures Range

University of Alabama at Birmingham. ObGyn Residency. Laparoscopy Training Lab PGY 1-4. Individual Pelvic Trainer Tasks

STAPLING SOLUTIONS FOR CHALLENGING APPLICATIONS. Stapling Product Catalogue 2016

ETHICON Wound Closure Suture Products. ETHICON Wound Closure Suture Products. International Market Development

Australian designed sutures for large animal surgeries 2016 CATALOGUE

Minimal Invasive Surgery develops very fast. In all field of surgery users search ways to use this technique for various indications.

Chirurgische materialen

The use of sutures and ligatures is an integral part of surgical procedures. Being proficient in suturing and ligating will not only make your

Intracorporeal Knot-Tying and Suturing Techniques in Laparoscopic Surgery: Technical Details

MIS TECHNOLOGY GUIDE READ PRODUCT INSERT THOROUGHLY BEFORE USE

WHEN IT COMES TO SUTURING, EXPERIENCE MATTERS.

WHEN IT COMES TO SUTURING, EXPERIENCE MATTERS.

Champion Instrumentation. Shoulder Repair Made Simpler

Monofilament polypropylene Suture

Tianjin Onehealth Medical Instruments. Onehealth Your surgical solutions partner

Techniques of the hand tie and instrument tie

The OPUS AutoCuff System for Rotator Cuff Repair

Cost savings without compromise

Hu-Friedy PERMA SHARP SUTURES HIGH PERFORMANCE PRECISE RESULTS

18-8 stainless steel surgical needles. coated, braided synthetic sutures VIAMAC REACT* coated, black braided sutures

Dr. S.D. Gerber Double Row Method Surgical Technique

ARTHROSCOPIC ROTATOR CUFF REPAIR SURGICAL TECHNIQUE. The following techniques are described by Vernon J. Cooley, M.D.

E N O V A n e e d l e s

Super Revo. Surgical Technique. Super Revo Shoulder Fixation System. The Ideal Fixation Device For Rotator Cuff Repair. Self-drilling, titanium anchor

C A R D I O VA S C U L A R P R O D U C T S C ATA L O G

LabraLock P for Labrum Repair, LabraFix System. The Reinforcement Technique Guide

tevdek ii the specialist green, polyester, braided suture material With special ptfe coating indications needle OVeRVieW ROunD bodied needles

SUTURES POCKET GUIDE PRODUCT INFORMATION

Selection and use of surgical needles

Novosyn Quick Your fast and efficient solution for a better quality of life

Objectives. xxx00.#####.ppt 5/10/17 9:42 AM

Transforming Surgical Robotics. 34 th Annual J.P. Morgan Healthcare Conference January 14, 2016

Explanation of a Typical Selection And Page

High polish finish. Complete line of biters, tissue graspers

SUTURA Nonabsorbable surgical suture U.S.P Black Braided Silk.

Hu-Friedy PERMA SHARP SUTURES HIGH PERFORMANCE PRECISE RESULTS

Product Pamphlet. Parcus Medical s Value Proposition Program is designed to reduce cost per case by:

Rotator Cuff Repair ICONN Answer PEEK Suture Anchor 4.75/5.5. Surgical Protocol by Geoffrey Connor, 4.75/5.5 MD of D1 Sports Medicine

Double Row Rotator Cuff Repair. Surgical Protocol by Frank Bonnarens, M.D.

Expertise in Surgery.

Horizon. Your innovative partner in medicine technology.

The Perfect Close. to your surgical procedure. PER F ORM ANC E through innovation

Veterinary Sutures & Bottles

Suture anchors for VeterinarY use

Simple Interrupted Suture (using a silicon skin pad)

SCANLAN LEGACY. High Precision Titanium Instruments

The Perfect Close. to your surgical procedure. PER F ORM ANC E through innovation

PARS Achilles Jig System

ADVANCED TISSUE-MANAGEMENT

Equine Laparoscopy Set by Mariën

Arthroscopic Protector Meniscus Suturing Surgical Techniques

PARS Achilles Jig System Surgical Technique

Anterior Cervical Plate SURGICAL TECHNIQUE GUIDE. Surgeon Driven Innovation

Strength of sliding knots in multifilament resorbable suture materials

Making Skin Closure Fast and Simple.

Image guidance reinvented. Foresight. Intracardiac Echo System

INTRODUCTION AND HISTORICAL PERSPECTIVE

Simple Interrupted Suture (using a tea towel)

SUTURES AND AEOS EPTFE MONOFILAMENT

Reliability and precision our suture materials NON-ABSORBABLE. Surgical sutures. Convincing down to the smallest detail

Surgical Sutures Market By Product Type [Automated Suturing Devices (Disposable Automated Suturing Devices, And Re-Usable Automated Suturing

T i t a n i u m I n s t r u m e n t s

MonoPlus. THE LONG-TERM OPTION FOR SLOW HEALING Synthetic long-term absorbable monofilament suture made of polydioxanone

Integra. Capture Screw System SURGICAL TECHNIQUE

Fax Japan São Paulo (SP) Tokyo Minato-ku , Minami-Aoyama. St. Jude Medical Brasil Ltda.

SE - MH 28 LL. Example. R Trocar. S Straight. 1 Eye shape. Point shape. Curvature. Number. Additional information* F=Fine L=Thick LL=Extra thick

HCS 2.4/3.0. The countersinkable compression screw.

MEDICAL/SURGICAL CUTTING INSTRUMENTS

Double Row Rotator Cuff Repair. Surgical Protocol by Frank Bonnarens, M.D.

STILLE Micro Instruments. Solid Performance - Outstanding Precision

Integra. Stainless Headed Compression Screw System SURGICAL TECHNIQUE

Choice. Collaboration. Value. Sharpoint PLUS Surgical Suture Catalog

HOLD FAST WITH EVERY PASS

Digital Compression Screw

1 May Telesurgery with haptic sensation: The future of surgery. Michael Stark The New European Surgical Academy (NESA)

Analysis and Physics of Laparoscopic Intracorporeal Square-Knot Tying

KEY SURGICAL WIRE AND PIN MANAGEMENT

Knotless SutureTak Instability Repair. Surgical Technique

DSL# EC 2009 Ethicon Endo-Surgery. All rights reserved PRODUCT CATALOG

Technique Guide. Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

Lorenz Plating System LactoSorb Resorbable Fixation. Anticipate. Innovate ṬM

PROGRAM CHAIR. Joseph (Jay) L. Hudgens, MD & Fariba Mohtashami, MD

Surgical Technique. Customer Service:

Interlagos Retractor System Surgical Technique

WOUND CLOSURE PRODUCTS

Prostar XL Percutaneous Vascular Surgical Device

MaxTorque. surgical technique. Cannulated Screw System. Foot & Ankle. OrthoHelix Technology

Technique Guide. 4.5 mm Cannulated Screws. Part of the Synthes Cannulated Screw System.

Arthroscopic Rotator Cuff Repair

anchor surgical needles and other OR related products

SUTURE MATERIALS PRINCIPLES OF SUTURE SELECTION PRINCIPLES OF SUTURE SELECTION... 32

Bi-directional barbed suture in laparoscopic myomectomy: a clinical study

ETHICON PRODUCT CATALOG. Sutures/Adhesives/Drains/Hernia Repair

Thoracoscopic First Assistant

SUTURES AND WOUND CLOSURE TECHNIQUES. An Introductory Guide

OPERATIVE TECHNIQUE RIVAL BITE HEADED CANNULATED AND HEADLESS COMPRESSION SCREWS. foot & ankle applications

OPHTHALMIC SUTURES SUTURES ULTRAPLUG PUNCTAL PLUGS PUNCTAL PLUGS PRODUCT INDEX

Transcription:

Suturing simplified. The first and only reusable, articulating, curved needle driver.

Articulating, An articulating curved needle driver, the Endo360 device is an MIS-enabling tool that allows the placement of a needle in tight places or difficult angles while suturing. The tapered tip of the curved, self-righting needle and wristed articulation enable precise placement on any tissue plane to approximate tissue, run a stitch, or reproduce any suturing technique in a MIS setting. Endo360 Precision curved needle Suture swaged to needle Siliconized needle Precision needle point I prefer to suture the cuff closed in a total laparoscopic hysterectomy with Endo360 because I can get full thickness bites of mucosa and reduce the risk for dehiscence. Jay Staub, MD, OBGYN, Dallas, TX

curved needle precision. Laparoscopic skills are difficult to master and maintain. Using disposable instruments without a curved needle can add frustration, increase intra-operative time and limit the clinical capability of the instrument. The Endo360 simplifies the most difficult tasks in surgery and makes it easy to tie intracorporeal knots. Made of stainless steel, the reusable Endo360 device comes in multiple lengths that safely hold a curved needle. A fully warranted cost-effective MIS enabling tool the Endo360 device is now available in your area. Articulation control Roticulation control Simple handle squeeze rotates curved needle 360 Distal tip articulates 40 for precise needle placement 180 rotation of distal tip

Clinical advantages of the The suture is not dragged through the hole alongside the needle, as with other devices, so there are far fewer incidents of leaks than when using larger needles. Scott Stowers, MD, ASMBS Fellow, Decatur, TX The Endo360 is consistently associated with significantly less time for suturing and knot tying for surgeons across varied levels of experience as compared to traditional laparoscopy. Steven G. Leeds, Lizzy Wooley, Ganesh Sankaranarayanan, Sanket Chauhan, Baylor University Medical Center, Dallas, TX The Endo360 driver speeds up my suturing time significantly. The ability to rotate and articulate with a curved needle allows me to get really full thickness bites. Nicole Pecquex, MD, FAMBS, Boston, MA

Endo360 FLAT PLANE SUTURING With just one suturing driver, the Endo360, I can complete many different suturing techniques. I can suture along the abdominal wall, gaining full thickness bites, tie intracorporeally, easily do a running stitch thru mesh, even trocar port closure efficiently. 8mm 6mm DEPTH OF BITE Paresh Shah, MD, NYU, NY The curve of the needle, its sharpness and linear suture arrangement, along with the precision of the needle placement, give me the confidence to suture through delicate tissues such as the anterior wall of the esophagus. Randy Wright, MD, Board-Certified General Surgeon, Decatur, TX WRISTED ARTICULATION SAFETY I had been using the Endostich device for at least 10 years in my practice... the Endo360 has a natural smooth curved needle penetration through the tissue, resembling manual suturing, except much easier and faster. I use it in all my laparoscopic cases where suturing is necessary. MESH Gintas Antanavicius, MD, FACS, FASMBS, Warminster, PA KNOTTYING NEEDLE PLACEMENT

The Endo360 is reusable. The reusable Endo360 offers two significant advantages: Less waste. Reduced costs. 30% of hospital waste originates in the OR. Red bag waste disposal is 10-15 times more costly than regular disposal. Using reusable products provides a means to decrease regulated medical waste generated in the OR by an average of 65%, as well as reduce the cost of waste disposal. 1 Endo Stitch Capio CL RD 180 Reinforcement strips Staplers Ti-Knot Knot Pusher Ti-Knot Quick Load CT/SH Needles Tackers Endo Close Glue SILS Stitch Endo360 can decrease the use of multiple disposables in one surgical case. Our mission is simple: To mirror the motion of manual suturing using a curved needle. We believe suturing is the most difficult task in surgery. That s why our mission is to mirror the motion of suturing by hand, using a curved needle, whenever a suture is needed. 1) Conrady, J., Hillanbrand, M., Myers, S., Nussbaum, GF. Reducing Medical Waste. AORN J 2010 Jun;91(6):711-21

Available with a full complement of Made in Italy standard and barbed sutures. Codes Description box REUSABLE LAPAROSCOPIC SUTURING DEVICE ECDL-01 Standard Laparoscopic length (374 mm) 1 ECDS-01 Shorter length for Uroginaecology and natural orifice procedures (222 mm) 1 ECDX-01 Longer length for Bariatric and Single-Port (449 mm) 1 CARTRIDGES FOR DISPOSABLE SUTURES FS028HHAA Filbloc, absorbable, barbed suture, in Polydioxanone, unidirectional with final lock system, USP 2/0, length 10 cm FS028HHAB Filbloc, absorbable, barbed suture, in Polydioxanone, unidirectional with final lock system, USP 2/0, length 15 cm FS028HHAC Filbloc, absorbable, barbed suture, in Polydioxanone, unidirectional with final lock system, USP 2/0, length 20 cm FU061HHAC non-absorbable, barbed suture, in Polypropylene, unidirectional with final lock system, USP 3/0, length 20 cm PS028HHAC Filbloc Permanent, non-absorbable, barbed suture, in Polypropylene, unidirectional with final lock system, USP 2/0, length 20 cm PU061HHAC Filbloc Permanent, non-absorbable, barbed suture, in Polypropylene, unidirectional with final lock system, USP 3/0, length 20 cm FS028M Assufil Monofilamento, PDO absorbable suture, taper needle, USP 0, length 45cm FU061M Assufil Monofilamento, PDO absorbable suture, taper needle, USP 2/0, length 45cm FV062M Assufil Monofilamento, PDO absorbable suture, taper needle, USP 3/0, length 45cm PS028 Assupro, Polypropylene, non-absorbable monofilament, taper needle, USP 0, length 45cm PU061 Assupro, Polypropylene, non-absorbable monofilament, taper needle, USP 2/0, length 45cm PV062 Assupro, Polypropylene, non-absorbable monofilament, taper needle, USP 3/0, length 45cm FS028 Assufil, absorbable, braided polymer of glycolic acid, taper needle, USP 0, length 45cm FU061 Assufil, absorbable, braided polymer of glycolic acid, taper needle, USP 2/0, length 45cm FV062 Assufil, absorbable, braided polymer of glycolic acid, taper needle, USP 3/0, length 45cm FS028W Assufil (undyed), absorbable, braided polymer of glycolic acid, taper needle, USP 0, length 45cm FU061W Assufil (undyed), absorbable, braided polymer of glycolic acid, taper needle, USP 2/0, length 45cm FV062W Assufil (undyed), absorbable, braided polymer of glycolic acid, taper needle, USP 3/0, length 45cm QS028 Astralen, non-absorbable, braided Polyester, taper needle, USP 0, length 45cm QU061 Astralen, non-absorbable, braided Polyester, taper needle, USP 2/0, length 45cm QV062 Astralen, non-absorbable, braided Polyester, taper needle, USP 3/0, length 45cm KS028 Assusilk, non-absorbable, braided silk suture, taper needle, USP 0, length 45cm KU061 Assusilk, non-absorbable, braided silk suture, taper needle, USP 2/0, length 45cm KV062 Assusilk, non-absorbable, braided silk suture, taper needle, USP 3/0, length 45cm FS028F Monofil, absorbable monofilament in Poli (glicolide-co-ἑ-caprolactone), taper needle, USP 0, length 45cm FU061F Monofil, absorbable monofilament in Poli (glicolide-co-ἑ-caprolactone), taper needle, USP 2/0, length 45cm FV062F Monofil, absorbable monofilament in Poli (glicolide-co-ἑ-caprolactone), taper needle, USP 3/0, length 45cm ENDO 360 INSTRUMENT TRAYS ECDT-00 Tray for one device (various lengths) 1 ECDT-01 Tray for two devices (various lengths) 1 ECDX-01 Longer length for bariatric and single port ECDL-01 Standard laparoscopic length ECDS-01 Shorter length for natural orifice procedures

FDA Class 1 exempt device 11 Issued US and 23 International Patents 4 US and 29 International Patents Pending Product of the USA Rx Only Federal (USA) Law restricts this device to sale, distribution and use by or on the order of a physician. Endo360 minimally invasive suturing devices are provided NON-STERILE and must be sterilized by compatible sterilization methods outlined in the Instructions for Use (IFU) document. Endo360 minimally invasive suturing devices are REUSABLE instruments and must be performancetested according to the test protocol in the Instructions for Use document prior to each use. NOTE: Use of Endo360 minimally invasive suturing devices requires a compatible EndoEvolution Endo360 suture. ITALY Headquarter Zona Industriale 67062 Magliano dei Marsi (AQ) Tel. +39 0863 517956 Fax. +39 0863 570084 Legal Office Via G. Gregoraci, n. 00173 Roma Tel. +39 06 72677348 Fax +39 06 72675380 www.assuteurope.com info@assuteurope.com DEVICES MADE IN THE USA. DISPOSABLE SUTURES MADE IN ITALY. 2016 EndoEvolution, LLC. EndoEvolution, Endo360 and the Endo360 logo are trademarks of EndoEvolution, LLC. SP50811 Rev04