INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection to Bürkert devices in remote versions Type 8030 can be combined with... Type 80 Flow transmitter Type 86 Universal Controller econtrol Type 880-GD Continuous TopControl system PLC The paddle wheel flowmeter for continuous flow measurement is especially designed for use in neutral, slightly aggressive, solid free liquids. The flowmeter is made up of a compact fitting (S030) and an electronic module (SE30) quickly and easily connected together by a Quarter- Turn. The Bürkert designed fitting system ensures simple installation of the devices into all pipes from DN06 to DN6. The flowmeter produces a frequency pulse signal, proportional to the flow rate, which can easily be transmitted and processed by a Bürkert transmitter/ controller. General data Compatibility Materials Housing, cover Cable plug Wetted parts materials Fitting, sensor armature Paddle wheel Axis, bearing / Seal With fittings S030 (see corresponding data sheet) PC PA Brass, stainless steel.4404/36l, PVC, PP, PVDF PVDF Ceramics / FKM (EPDM option) Electrical connection Cable plug EN 730-803 Connection cable. mm cross section; max. 0 m length, shielded Complete device data (fitting + electronic module) DN06 to DN6 Measuring range 0.3 to m/s Medium temperature with fitting in PVC / PP Stainless steel, brass, PVDF Medium pressure max. 0 to 0 C (3 to F) / 0 to 80 C (3 to 76 F) - to 0 C ( to F) PN (with plastic fitting) PN6 (with metal fitting) (PN40 on request, see S030 data sheet) 300 cst. max. / max. % (Size of particles 0. mm max.) Viscosity / Pollution Accuracy Teach-In Standard K-factor Linearity ±0.% of F.S.* (at m/s) ) Repeatability 0.4% of Reading ) ±0.% of F.S.* (at m/s) ) ±(0.% of F.S.* +.% o. Reading) ) Environment Ambient temperature - to + 60 C ( to 40 F) (operating and storage) Relative humidity 80%, without condensation * F.S. = Full scale ( m/s) ) Under reference conditions i.e. measuring fluid = water, ambient and water temperature = C (68 F), applying the minimum inlet and outlet pipe straights, matched inside pipe dimensions. www.burkert.com p. /
Electrical data Operating voltage Current consumption Pulse version Pulse Low power version Output: Frequency Pulse version Pulse Low Power version Reversed polarity of DC Standards and approvals Protection class Standard and directives EMC Pressure Vibration Shock - 36 V DC (via Bürkert transmitter for Low Power version) with sensor 30 ma 0.8 ma Transistor NPN/PNP, open collector, max. 0 ma, frequency: 0... 300 Hz; duty cycle / Transistor NPN, open collector, max. ma, frequency: 0... 300 Hz; duty cycle / Protected IP6 with connector plugged-in and tightened EN 600-6-, 600-6-3 Complying with article 3 of 3 from 97/3/CE directive.* EN 60068--6 EN 60068--7 * For the 97/3/CE pressure directive, the device can only be used under following conditions (depend on max. pressure, pipe diameter and fluid). Type of fluid Fluid group,.3.a Fluid group,.3.a Fluid group,.3.b Fluid group,.3.b Conditions DN only DN 3 or DN > 3 and PN*DN 00 PN*DN 00 DN 0 Accuracy diagram Pressure / temperature chart A: Application range for complete device (fitting + flowmeter) p. /
8030 Design and principle of operation The flowmeter 8030 is built up with an electronic module SE30 associated to a fitting S030 with integrated measurement paddle wheel. This connection is made by means of a Quarter-Turn. In a 3-wire system, the signal can be displayed or processed directly. The output signal is provided via cable plug according to EN 730-803. When liquid flows through the pipe, the paddle-wheel is set in rotation. The non-wetted permanent magnets inserted in the paddle wheel generate a measuring signal which frequency is proportional to the flow velocity. A conversion coefficient (K-factor, available in the instruction manual of the fitting), specific to each pipe (size and material) enables the conversion of this frequency into flow rate. Two electronic module versions with frequency output are available: - with one pulse output (either NPN or PNP transistor output depending on wiring). An external power supply of - 36 V DC is required. It is designed for connection to any system with open collector NPN or PNP frequency input. - with one pulse Low Power output (NPN transistor output). An external power supply of - 36 V DC is required. Can only be connected to separate versions of flow transmitters Type 80/803. Installation The 8030 flowmeter can easily be installed into any Bürkert INLINE fitting system Type S030, by means of a Quarter- Turn. Minimum straight upstream and downstream distances must be observed. According to the pipe s design, necessary distances can be bigger or use a flow conditioner to obtain the best accuracy. For more information, please refer to EN ISO 67-. EN ISO 67- prescribes the straight inlet and outlet distances that must be complied with when installing fittings in pipe lines in order to achieve calm flow conditions. The most important layouts that could lead to turbulence in the flow are shown below, together with the associated prescribed minimum inlet and outlet distances. These ensure calm, problem-free measurement conditions at the measurement point. DN = pipe diameter Flow direction --> Control valve x 90 elbow joint expansion x 90 elbow joint 3 dimensional 90 elbow joint or T-piece reduction The device can be installed into either horizontal or vertical pipes. Pressure and temperature ratings must be respected according to the selected fitting material. The suitable pipe size is selected using the diagram Flow/Velocity/DN. The measuring device is not designed for gas flow measurement. p. 3/
Diagram Flow/Velocity/DN Dimensions Example: Flow: m 3 /h Ideal flow velocity:...3 m/s For these specifications, the diagram indicates a pipe size of DN40 [or DN0 for (*) mentioned fittings] Flow rate of fluid gpm 00 00 0 0 0 0. 0. 0. 0.0 l/min 3000 00 00 00 0 0 0 0. 0. m 3 /h 0 0 0 0. 0. 0. 0.0 0.0 Not recommended 0.0 0. 0.3 0. 3 m/s 0.3 0. 3 30 DN6 DN0 (DN6)* DN40 (DN0)* DN3 (DN40)* DN (DN3)* DN (DN)* DN (DN or DN)* DN08 DN06 fps Flow velocity DN [mm] H [mm] 06 9. 08 9. 0. 98.0 98.0 3.0 40. 0.0 * for following fitings with: external threads acc. to SMS 4 weld ends acc. to SMS 3008, BS 48/ASME BPE or DIN 80 Series Clamp acc. to SMS 307/ISO 8, BS 48/ASME BPE or DIN 3676 p. 4/
Ordering chart for flowmeter Type 8030 A flowmeter Type 8030 consists of: - an electronic module Type SE30 - an INLINE fitting Type S030 (DN06 to DN6 - Refer to corresponding data sheet) Description Voltage supply Output Electrical connection Item no. Pulse version flowmeter (pluggable to Types 80 Universal transmitter, batch controller or konti-dos; 803; PLC) Pulse Low Power version flowmeter (pluggable to Types 80, 803 transmitter) - 36 V DC Frequency with pulse, PNP or NPN Cable plug EN 730-803 43 93 from associated transmitter Frequency with pulse, NPN Cable plug EN 730-803 43 94 Ordering chart for accessories (has to be ordered separately) Specifications Item no. Cable plug EN 730-803 with cable gland (Type 08) 438 8 Cable plug EN 730-803 with NPT/ reduction without cable gland (Type 09) 6 673 Interconnection possibilities with other Bürkert products Type 80 - Universal, konti-dos flow transmitter/batch controller Type 803 - Flow switch/transmitter Type 80 - Flow transmitter Type 803 - Flow switch/transmitter PLC Type 8030 - Flowmeter with Hall transducer (pulse signal) Type 8030 - Flowmeter with Hall Low Power transducer (pulse signal) To find your nearest Bürkert office, click on the orange box www.burkert.com In case of special application conditions, please consult for advice. Subject to alteration. Christian Bürkert GmbH & Co. KG 7/_EU-en_0089778 p. /