Trap Series. Features: Description. Technologically Advanced: 2Km Range Protective Rubber Boot 1, 4 and 16 Switch versions

Similar documents
SABRETrap Control. Description

HORNET Remote Control Systems

SmartRadio control system

FOBBER - FM Key Fob. Description. FM (FSK) Key fob Sleek and compact design Range up to 200metres 1-8 Switch variants 433 / 868MHz Options

KAPPA-T868SO. Smart Radio Telemetry Module

BRAVO. SmartRadio Telemetry Module

HURRICANE Radio Modem. FULL DUPLEX Radio MODEM

VIPER Remote Control Systems

FIREFLY FIREBLADE RADIO REMOTE CONTROL SYSTEMS. Applications

KAPPA M. Radio Modem Module. Features. Applications

118, 128, KEELOQ REMOTE CONTROL SYSTEMS, 12 / 24Vdc,

AM / FM RADIO TRANSMITTER KEYFOBS

Arduino Arduino RF Shield. Zulu 2km Radio Link.

PRO Professional Radio Control Series Applications

PROFLY / PROBLADE Professional Radio Control PRO-BLADE8

Modular Radio Telemetry System

DatasheetDirect.com. Visit to get your free datasheets. This datasheet has been downloaded by

Modular Radio Telemetry System

200, 201 Series Radio Telemetry Transmitters

LAMBDA. LongRange (LoRa) Transceiver. Features. Applications. Description

RF RECEIVER DECODER RDF1. Features Complete FM Receiver and Decoder. Applications

Remote Switching. Remote Gates. Paging.

Remote Switching. Remote Gates. Paging.

Installation instructions

WSA 8 BOX RELE Installation Manual

Astra-R Kit Wireless Alarm System Operation Manual

User Guide. Keysight N6850A Broadband Omnidirectional Antenna

MINIATURE AM / FM DECODER MODULES

ALPHA Encoder / Decoder IC s

Radio receivers type DB317 and DBR1-M4

PRODUCT MANUAL. AGD Systems Limited 2016 Doc. Ref. 932 PM ISS3 ISO ISO 9001 Registered Quality Management. Registered Environmental Management

Wiring Instructions for 10, 16 & 20 Function, 92 & 93 Series, FET Receivers.

SmartRadio Transmitter / Receiver

Radio Encoder / Decoder IC s

X80 Activator. User's Manual. Version 1.1.

Wireless Room Thermostat Installation and Operation Y6630D1007

Parameter Test Conditions Units Min. Typ. Max. RFC to T X RFC to R X. P IN = +23 dbm, AC 80 MHz / 256 QAM

Wireless Receiver E28Q Mounting and Operating Instructions (Original operating instructions)

DUAL BAND FM WIRELESS TRANSCEIVER RXQ1. Applications

PixController, Inc. Wireless Vibration Sensor For Indoor and Outdoor Use

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

FM Radio Transmitter & Receiver Modules

Radio Control Installation and Operating Instructions System 4

Part Ordering code Marking Remarks Package BFR90A BFR90AGELB-GS08 BFR90A Packed in Bulk TO-50(3)

Tele Radio T70 Jaguar

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

Absolute Maximum Ratings Parameter Rating Unit Voltage 6.0 V Maximum input power (0.6 GHz to 2.5 GHz), RF1, RF2 +28 dbm Operating temperature -30 to +

Operating Instructions

GLR43308 and GLR2708. Setup and programming instructions. for the 8 channel Gigalink receiver. Programming Videos

Important safety instructions

Register your product and get support at AE2330. User manual

Panther. Installation instructions. Receivers PN-R15-1 PN-R15-2 PN-R15-13 PN-R IM-PN-RX103-A03-EN Language: English (original)

RF Remote Control Unit SEAV

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

WIRELESS MOTION SENSOR USER MANUAL MULTI LANGUAGE START-LINE TRANSMITTER APIR-2150

1 Form A Solid-State Relay

SPECIFICATION. Product Name : Heavy Duty Screw Mount Antenna MIMO Dual Band 2.4/5.0GHz

Panther. Installation instructions. Receivers PN-RX-MN5 (PN-R8-1) PN-RX-MN5E (PN-R8-10) PN-RX-MD11 (PN-R8-6) PN-RX-MD11E (PN-R8-11)

SKY LF: PHEMT GaAs IC SP3T Switch GHz

SDM4101. Description. Features. Agency Approvals. Applications. Absolute Maximum Ratings. Schematic Diagram. Ordering Information.

FM Radio Transmitter & Receiver Modules

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

Broadband LDMOS driver transistor. A 5 W LDMOS power transistor for broadcast and industrial applications in the HF to 2500 MHz band.

SPECIFICATION. MIMO Single Band 2.4GHz. ISM Bands/ZigBee/WLAN/Bluetooth. High Isolation between Antenna Elements. UV and vandal resistant PE housing

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

A1800 ALPHA meter special installation instructions DANGER

Installation and user s guide H A. NCi-5 non-contact tool setting interface

Remote Radio Control. M880 WAVE2 C Transmitter Range. M880 for Low Integrity Stop Circuit Applications

FO-TX 2-EC FO-TX 2-OPT FO-RX 2-EC

FM-RRFQ SERIES FM TRANSMITTER & RECEIVER HYBRID MODULES. Transmitter. Receiver. Applications

QM Radio Transmitter Module

OCTOPUS CONTROL STATION

Earth Fault Indicator EFI-BLZ-50 User Manual

SKY LF: PHEMT GaAs IC High-Power 4-CTL DPDT Switch LF 6 GHz

Getting started with the 2 Port Antenna Switch

UR200SI / UR200WE ENGLISH

Small Signal Fast Switching Diode FEATURES

SMARTALPHA RF TRANSCEIVER

UHF Narrow band radio data module CDT-TX/RX MHz

Model: &

SF Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

Part Ordering code Marking Remarks BAV99-V BAV99-V-GS18 or BAV99-V-GS08 JE Tape and Reel

Response Plus & Link Paging Systems Data Sheet

Outdoor wireless double wall switch

OPERATING GUIDE RADIO LOCATOR. Please read this entire guide before beginning

High Speed Infrared Emitting Diode, 870 nm, GaAlAs Double Hetero

SKY LF: GaAs SP2T Switch for Ultra Wideband (UWB) 3 8 GHz

Linear Optocoupler, PCMCIA Package

SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

M291 1 Form A. Features. Description. Agency Approvals. Applications. Absolute Maximum Ratings. Schematic Diagram. Ordering Information

AD6C311-HSTR. Features. Description. Agency Approvals. Applications. Absolute Maximum Ratings. Schematic Diagram. Ordering Information.

SPA WIRELESS SWITCHES AND RECEIVERS MANUAL

Panther. Installation instructions. Transmitters PN-TX-MD3M (PN-T13-3) PN-TX-MD4M (PN-T13-4) PN-TX-MD6M (PN-T13-6) PN-TX-MD8M (PN-T13-8) PN-TX-MD10M

Owner s Manual PMR 446 Handheld transceiver G5

Operating Instructions DBH03R - 80 Channel 0.5 watt UHF Hand held CB radios with rechargeable batteries & USB charge cable.

TireHandler Radio Remote System

TR-62D. Data Sheet. Transceiver Module for Wireless M-Bus. Preliminary MICRORISC s.r.o. DSTR62D_ Page 1

Operator s Manual. PP016 Passive Probe

USER MANUAL CR Please read this user manual carefully before start using the product.

Splash-proof Wireless Stereo Speaker System User s Manual

Transcription:

Trap Series Features: Waterproof Receiver IP68 One Transmitter to Many receivers Robust and reliable Technologically Advanced: 2Km Range Protective Rubber Boot 1, 4 and 16 Switch versions The TRAP system delivers reliable operation 365 days of the year. This rugged professional system is designed to meet the heavy usage needs associated with club traps. Each receiver has four independent outputs which can easily be paired with individual switches from one or many different transmitters. Building a bespoke control system is easy with transmitters containing up to 16 switches. DS-TRAP-3

System part numbers TRAP-S1 Single channel system TRAP-S4 Four channel system Additional transmitters SABRE Transmitters are available individually with 1, 3 or 8 buttons and can be configured to work any TRAP-T1 TRAP-T2 TRAP-T4 TRAP-T16 Transmitter 1 switch Transmitter 2 switch Transmitter 4 switch Transmitter 16 switch Additional receivers These can be used with any existing TRAP transmitter or SABRE transmitter TRAP-RX Receiver Unit. DS-TRAP-3 PAGE 2

Connecting the receiver unit. The TRAP system provides 4 Relay switches each capable of switching up to 1.2KW (5A @ 230V). Each relay is independent and separately controlled. The TRAP series remote control system provides switched contacts and can therefore be used to switch most voltages either AC or DC. 1. Open the enclosure by removing fixing screws from the enclosure front and then removing the front from the enclosure. 2. Connect the power supply screw terminals 12-32V ac or dc to the low voltage terminals. 3. Wire your desired connections to the relay switches 4. Once all required wiring is complete, use the handheld TRAP transmitter to switch the outputs on and off. 5. As supplied, the handheld will operate the outputs - Button 1 to output 1, Button 2 to output 2 etc. 6. For additional functions including operation such as adding extra transmitters, different button map ping options, changing the outputs to latching, see advanced operation section. Application Circuit. NO COM 12V NC LOAD 0V Relay Relay TRAP-RX Relay 12V 0V Supply Terminals Notes for clay pigeon release applications PLEASE READ BEFORE ATTEMPTING INSTALLATION: This system is supplied complete with cable in order to connect to the clay trap release. Warning : Not all clay traps have the same wiring convention! The system is pre-wired (as diagram below) before connecting, CHECK YOUR CONNECTIONS. (using a multi-meter) if you are in any doubt, DO NOT CONNECT THE SYSTEM, consult a qualified Electrician. Although the system operates on 12-32V DC damage may occur to the receiver unit if wrong connections are made. For easy installation we offer the following prewired Systems Promatic Laporte Acorn Autosporter TRAP-S1PROM TRAP-S1LAP TRAP-S1ACORN TRAP-S1AUTO DS-TRAP-3 PAGE 3

Advanced Operation Configuring receivers Receivers can be used for many applications. The Link Pins LK1 and LK2 set the action of the relays = Relay will operate for 1 / 2 sec Mom = Relay will operate for as long as transmitter switch operated Latch = Relay will toggle ON/OFF on each transmitter button press Link Pins LK1 LK2 Link Positions Switched outputs LK1 LK2 RLY 1 RLY 2 RLY 3 RLY 4 Open Open Closed Open Mom Mom Latch Latch Open Closed Mom Mom Mom Mom Closed Closed Latch Latch Latch Latch DS-TRAP-3 PAGE 4

Advanced operation - Pairing a transmitter button With this system, you can pair together any individual transmitter switch with any receiver output relay. Without opening either box. 1. Remove the green transmitter rubber overboot 2. Briefly (for less than 1 second) place the transmitter next to the receiver in the position shown and then remove it. 3. The receiver will Buzz once (One Buzz means the receiver unit is ready to allocate a transmitter to Relay switch 1) 4. Press the switch on the transmitter which you wish to pair 5. The receiver will buzz twice to confirm pairing 6. Repeat for any additional transmitter switches NOTE: each receiver has a maximum memory for up to 28 pairings, these can be from any Switches on any transmitters! Advanced Note: It is possible to select relay output switches 2-4, by repeating step 3 and counting the number of buzzes. 2 buzzes for relay 2 3 for 3 etc. Advanced operation - Erasing receiver memory 1. Hold the transmitter in the position shown in position for ~5 seconds. 2. The receiver will sound a long buzz to confirm erased DS-TRAP-3 PAGE 5

Technical specifications Transmitters: TRAP-Transmitter Enclosure Rating: Standard IP67 (upgradeable to IP68) Battery Type: 3 x AAA (supplied) Battery Life: 5 years @ approx. 50 1/2second presses p/day Dimensions: 90 x 54 x 27 mm Changing the Battery: Remove the six enclosure screws. Remove 2 battery compartment screws and replace batteries, taking care of cables and battery polarity Receiver Decoder: TRAP-Receiver Enclosure Rating: IP68 Dimensions: 130 x 112 x 42 mm (not including antenna) Operating Temperature: -10 to +50 o Celsius. *The relay contacts in this unit are for functional use only and must not be used for isolation purposes Approvals Information: Electrical Characteristics Min Typical Max Units Supply Voltage 4.5 V Frequency: 869.500 MHz RF Output Power (ERP) @ 869.50 MHz - 100 mw ELECTRICAL CHARACTERISTICS MIN TYPICAL MAX DIMENSION Supply Voltage 12 12 32 V ac or dc Relay Rating* (230Vac) RLY1-4 5 12 A Supply Current : Quiescent All relays operating* 40 140 ma Time delay from Tx on Switch to Rx Relay operation 30 ms Time delay from Tx sw relax to Rx Relay release 30 ms All RF Solutions products are manufactured in accordance with our ISO:9001 Quality System Further information available on request. RF Solutions Ltd. Recycling Notice Meets the following EC Directives: DO NOT Discard with normal waste, please recycle. ROHS Directive 2002/95/EC Specifies certain limits for hazardous substances. Waste Batteries and Accumulators Directive 2006/66/EC Where batteries are fitted, before recycling the product, the batteries must be removed and disposed of at a licensed collection point. Environment Agency producer registration number: WEE/ WEEE Directive 2002/96/EC Waste electrical & electronic equipment. This product must be disposed of through a licensed WEEE collection point. RF Solutions Ltd., fulfils its WEEE obligations by membership of an approved compliance scheme. Whilst the information in this document is believed to be correct at the time of issue, RF Solutions Ltd does not accept any liability whatsoever for its accuracy, adequacy or completeness. No express or implied warranty or representation is given relating to the information contained in this document. RF Solutions Ltd reserves the right to make changes and improvements to the product (s) described herein without notice. Buyers and other users should determine for themselves the suitability of any such information or products for their own particular requirements or specification(s). RF Solutions Ltd shall not be liable for any loss or damage caused as a result of user s own determination of how to deploy or use RF Solutions Ltd s products. Use of RF Solutions Ltd products or components in life support and/or safety applications is not authorised except with express written approval. No licences are created, implicitly or otherwise, under any of RF Solutions Ltd s intellectual property rights. Liability for loss or damage resulting or caused by reliance on the information contained herein or from the use of the product (including liability resulting from negligence or where RF Solutions Ltd was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict RF Solutions Ltd s liability for death or personal injury resulting from its negligence. DS-TRAP-3 PAGE 6

Trap remote control System Range Test Notes Our Range Testing was conducted on Ditchling Beacon providing an open Line of Sight Test. 1. Receiver was mounted on the Bonnet of our vehicle in the Beacon Car park 2. The transmitter was carried along the beacon whilst being repeatedly operated 3. 2KM range was achieved, the system was working 100% however testing ceased as we ran out of land. 4. Weather Conditions 5. Warm, Dry, Sunny, Broken Cloud, 22degC Ditchling Beacon R F Solutions Ltd., William Way, Burgess Hill, West. Sussex. RH15 9AG. England. Email : sales@rfsolutions.co.uk http://www.rfsolutions.co.uk Tel Sales: 01444 227900 William Alexander House, William Way, Burgess Hill, West Sussex, United Kingdom, RH15 9AG Tel. Sales:+44(0)1444 227910 Tech Sales:+44(0)1444 227909