ORCA-50 Handheld Data Terminal UHF Demo Manual V1.0

Similar documents
INDY R2000 Module Series Specification

WJM1000. Next Generation RFID Reader Module Based on the WJC200 Gen2 RFID reader chipset. Key Features

LC-10 Chipless TagReader v 2.0 August 2006

TC-2600A RFID Tester

SPS1M-EVK. SPS1M-EVK Battery Free Wireless Sensor Handheld Evaluation System EVAL BOARD USER S MANUAL

PROMAG RWM600A. ISO/IEC15693 Advanced Reader Module. Overview. Features. Application. Specifications. Application Circuit

ST600 TRANSMITTER OPERATING INSTRUCTIONS

Integration of All Required Functions for Reader and Tag Testing into a single unit Supports 840 MHz ~ 960 MHz UHF RFID Supports ISO/IEC Air

Passive Sensors Technical Guide

1 UAT Test Procedure and Report

A step-by-step process for attaching a photo of the park through Android Mobile Application

SV613 USB Interface Wireless Module SV613

DragonLink Advanced Transmitter

Application Note: IQ Filtering in an RFID Reader Using Anadigm Integrated circuits,

Technical Documentation

MINIMUM SYSTEM REQUIREMENTS

Suitable firmware can be found on Anritsu's web site under the instrument library listings.

Quick Start Guide for the PULSE PROFILING APPLICATION

Instruction Manual ABM HART Gateway Software. Instruction Manual Revision A.1

Hytera. PD41X Patrol Management System. Installation and Configuration Guide

Getting Started with TrangoLink

Dual-band radio transmitter T10, Т10С T10U, T10UC

WPE 48N USER MANUAL Version1.1

DATE: 17/08/2006 Issue No 2 e-plate Operation Overview

Catalog

DRG-Series. Digital Radio Gateway. Motorola MotoTRBO DMR. Interfacing Omnitronics DRG with Motorola MotoTRBO DMR Digital Radios

Physical Inventory System User Manual. Version 19

Table of Contents. Chapter 1: Software Installation...1. Chapter 2: Running the Software II. Daily Practical Operation...10

ID Photo Processor. Batch photo processing. User Guide

Technical Note #15. Radio Frequency Modems. GE ED&C Home Search ED&C GE ED&C Power Management Home GE ED&C PMCS Home

IT-24 RigExpert. 2.4 GHz ISM Band Universal Tester. User s manual

technical report MHz ISM Band Class 1 Radio Frequency Identification Tag Interface Specification: Recommended Standard, Version 1.0.

CAD-MF. PC-Based Multi-Format ANI & Emergency ANI Display Decoder. Manual Revision: Covers Firmware Revisions: CAD-MF: 1.

Managing Radios and Radio Descriptors

PC Tune PC Tune Test Procedures for 5100 Series Portable Radios

Reader Configuration. Configuration Parameters for UHF RFID Reader DTE800 / DTE810 DTE900 / DTE910. Version 1.00

AcuMesh Wireless RS485 Network. User's Manual SOLUTION

EcoGreen Singapore RFID Products Catalogue

MPR kHz Reader

Catalogue

TEK-TROL HART GATEWAY SOFTWARE. Operating Instruction Manual.

GPRS-A. Universal monitoring module. Firmware version 1.00 gprs-a_en 04/18

G3P-R232. User Manual. Release. 2.06

Catalog

SV-MESH Mesh network series Catalogue

DataCAD Softlock License Activation and Management

TRANSCEIVER FSK. Version: 434 MHz Band / 868 MHZ Band / Code: / A

UHF RFID Integrated Reader. Software operation manual

ISO/IEC INTERNATIONAL STANDARD

Ground System Training Department

DRG-Series. Digital Radio Gateway. Kenwood NXDN Donor Radio (Tier-2) Interfacing Omnitronics DRG with Kenwood NXDN Donor Digital Radios (Tier-2)

DataCAD 18 Softlock. Universal Installer. Installation. Evaluation

instruction manual for Open LRS New Generation

Guardian and DL3282 Modem Interface Technical Service Application Note

Communication with FCC s Office of Engineering Technology Regarding ISM Compliance of Power-Optimized Waveforms

Coin vending controller

RF4432 wireless transceiver module

Model OT-1000-HH 1GHz SuperMod Optical Transmitter, DWDM ADVANCED OPERATING MANUAL

Politecnico di Milano Advanced Network Technologies Laboratory. Radio Frequency Identification

EDACS SYSTEM MANAGER. User s Guide. Mobile Communications. User s Guide For Version 3.XX (Group 3) LBI-38984

Mastr III P25 Base Station Transmitter Tune-up Procedure

Wireless sensor system

DRG-Series. Digital Radio Gateway. Hytera DMR USB Donor (Tier-2) Digital Radio Supplement

inphoto ID Canon and Olympus camera control software Automatic ID photography User Guide

Pressure Field Unit User Guide

Inventory Manual. Version 3. Hart ID = Have a question? Call Hart Client Care at , or us at

Chaos Communication Camp Milosch Meriac Henryk Plötz

Radio Frequency Identification

Federal Communications Commission Office of Engineering and Technology Laboratory Division

DRG-Series. Digital Radio Gateway. Tait P25 CCDI Tier-2 (TM9400 Series Mobile Radio) Digital Radio Supplement

RFID Door Unlocking System

TOSHIBA MACHINE CO., LTD.

GPRS-T2. GPRS/SMS Reporting Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

VisorTrac A Tracking System for Mining

GV-RU9003 UHF RFID Reader

SINGLE PHASE STS PREPAID METER

R&S RTO-K92 emmc Compliance Test Test Procedures

PROGRAMMING MANUAL PCCONFIGURE SOFTWARE. December 2004 Part No

Firmware version 1.05 supports all CMOS sensor based digital backs IQ150, IQ250 and A- series IQ250.

OEM 100. User Manual. Figure 1: OEM 100 Module with HG Rectangular Antenna Board

AN797 WDS USER S GUIDE FOR EZRADIO DEVICES. 1. Introduction. 2. EZRadio Device Applications Radio Configuration Application

Supply 12Vdc nominal (9 Vdc minimum, 14,5Vdc maximum ) Max Current Drain. from a , V Carrier Frequency

Wireless Howto. Rev 9

Blue Bamboo P25 Device Manager Guide

Field Software Notice

You should see the following screen when you first login to Student E-Service

AirScope Spectrum Analyzer User s Manual

Arduino Lesson 1. Blink. Created by Simon Monk

5008 Dual Synthesizer Configuration Manager User s Guide (admin Version) Version valontechnology.com

BCV-1203 Barcode Verification System Users Guide Version 1.2

Design of UHF RFID Emulators with Applications to RFID Testing and Data Transport

Remote Switching. Remote Gates. Paging.

INDEX...2 INTRODUCTION...3 IMPORTANT NOTES...3 INSTALLING THE SOFTWARE...3 ST-965 PROGRAMMING SOFTWARE...6

COMPACONLINE CARD MANAGEMENT MANUAL

Contrail TDMA Manager User s Reference

MAXI Remote Location Kit MRLK 900 Installation and Configuration Manual

Micro Fox PicCon Manual

RFID Multi-hop Relay Algorithms with Active Relay Tags in Tag-Talks-First Mode

ivu Plus Quick Start Guide P/N rev. A -- 10/8/2010

Configuration of the Pacific Crest Radios using PDLCONF software PDL Base Radio

Transcription:

ORCA-50 UHF Demo Manual V1.0 ORCA-50 Handheld Data Terminal UHF Demo Manual V1.0 Eximia Srl. www.eximia.it - www.rfidstore.it mario.difloriano@eximia.it 1 Eximia Srl www.eximia.it - www.rfidstore.it

Catelogue 1. UHF software operation and configuration... 1.1 Start the UHF Demo software... 1.2 Inventory ISO-18000-6C tag... 1.2.1 Ordinary inventory... 1.2.2 Advanced options... 1.3 Access ISO-18000-6C tags... 1.3.1 Read the tag operation... 1.3.2 Write the tag operation... 1.3.3 Lock the tag operation... 1.3.4 Inactivation the tag operation... 1.3.5 Select the tag operation... 1.3.6 Access the label may return an error message... 1.4 Inventory and access ISO-18000-6B tags... 1.4.1 Inventory ISO-18000-6B tag... 1.4.2 Access ISO-18000-6B tags... 1.5 RF parameter settings... 1.5.1 Set the RF output power... 1.5.2 Set the radio frequency spectrum specification... 1.5.3 Set the antenna connection to receive... 1.5.4 Measure the return loss of the current antenna port... 1.6 Other settings of the reader... 1.6.1 Monitor the operating temperature... 1.6.2 Set the buzzer status... 2. Develop your own RFID applications... 2 Eximia Srl www.eximia.it - www.rfidstore.it

2017 RodinBell reserves all rights reserved for this document 1. UHF software operation and configuration 1.1 Start the UHF Demo software Click the UHF Demo icon to enter the connection interface, select ttys1 (rk_serial) serial port, click on the immediate connection to enter the main interface: The main interface for the ISO-18000-6C tag inventory interface: 3 Eximia Srl www.eximia.it - www.rfidstore.it

1.2 Inventory ISO-18000-6C label Inventory label, which is to identify multiple labels at the same time EPC number, which is the core function of UHF RFID reader, its performance directly determines the merits of the reader 1.2.1 Ordinary inventory Click the Start Stock button or trigger the trigger of the handset handle. If the label is within the signal range, the EPC data of the label will be uploaded immediately and updated in real time. If you do not click on the end of the inventory or release the trigger, the reader will keep the inventory label, as shown below: 4 Eximia Srl www.eximia.it - www.rfidstore.it

The meaning of the data display is as follows: Inventoried Quantity There are a number of different tags that have been archived since the start of the inventory butto Speed Identify the speed of the label in units per second Total tag A label EPC record as a data, where real-time statistics to return a total of the number of data, which contains repeated read the same label data CMD exec time The time spent by each inventory command. The unit is milliseconds Total duration The total amount of time since the start of the inventory button was clicked. The unit is milliseconds The list of tags in the EPC number list (do not repeat) the meaning of the fields in the list box is as follows: ID The serial number of the data EPC The EPC number of the label PC Label protocol control word ID CNT The number of times the tag was identified RSSI The signal strength of the label is identified the last time Carrier frequency Carrier frequency of the label is identified the last time 1.2.2 Advanced options Click the Advanced Options checkbox next to the Start Stock button. The following interface appears: 5 Eximia Srl www.eximia.it - www.rfidstore.it

The number of times each command is stored: The meaning of this parameter is the number of times the command is repeated. For example, set to 1, each inventory command to perform an anti-collision algorithm. Set to 2, then each disk command to repeat the implementation of two anti-collision algorithm, and so on Custom Session parameters: Click the Custom Session parameter check box, Session ID and Inventoried Flag will become optional, then click the Start button, the reader will be a custom Session and Target inventory 1.3 Access ISO-18000-6C tags Click the "Access Tag" check box to access the interface of the access label, as shown below: 6 Eximia Srl www.eximia.it - www.rfidstore.it

The following will be one by one on how to carry out the label access operation 1.3.1 Read the label operation The parameters of the read tag are entered in the interface shown below: The read tag needs to enter three parameters: the label area to be read, the start address and the data length. Note that here the starting address and The data length units are WORD, which is 16 bit double bytes. When the parameter is set, click the Read tab button. It should be noted that the input parameters to meet the specifications of the label, otherwise there will be an error When the operation completes successfully, the feedback shown below appears: 7 Eximia Srl www.eximia.it - www.rfidstore.it

How many tags are displayed and how many pieces of data are displayed in the tag list 1.3.2 Write the label operation Write the interface of the label operation and read operations in the same area, the difference is that the write operation also need to provide access to passwords and write data to this information The password area is part of the electronic tag that stores the password (password). Including inactivation passwords and access passwords. The inactivation password and the access password are 4 bytes. Where: the address of the inactivation password is 00H-03H (in bytes); the address of the access password is 04H-07H After the operation is successful, the feedback shown below will appear: 8 Eximia Srl www.eximia.it - www.rfidstore.it

How many tags have been successfully operated, and how many pieces of data will be displayed in the list. Unlike the read tags, there is no content in the data column on the map above. The user can read the same area of the tag again to verify that the data is written correctly Note that the maximum write length is 32 Word(64 bytes,512bits) 1.3.3 Lock the label operation The operation interface of the lock label is shown in the following figure: The lock tag must be provided with an access password to proceed. Note: The original password lock is invalid, it is recommended that users first modify the access password and then lock the label After the operation is successful, the following information will be returned: 9 Eximia Srl www.eximia.it - www.rfidstore.it

Similarly, how many tags are displayed in the list, and how many pieces of data are displayed in the list 1.3.4 Kill the label operation The operation interface of the deactivation tag is shown in the following figure: The deactivation tag must provide an inactivation password and the inactivation password can not be 00 00 00 00. Therefore, to destroy a label, first change the contents of the password inactivation password by writing a tag command After killing tag is successful, the following information is returned: the list How many tags are displayed in the list, as with all access to the tag, how many records are displayed in 10 Eximia Srl www.eximia.it - www.rfidstore.it

1.3.5 Select the label operation In many cases, we hope that no matter how many labels in the RF area, only for a known EPC number of labels to access operations, this time, you need to use the selected operation of the label function (EPC matching function) In the accompanying demo software, operate as follows: First save the label, get all the EPC number And then go to the interface to access the tag, select the EPC number to match. As shown below: When the selection is complete, click the selected tab, as shown below: 11 Eximia Srl www.eximia.it - www.rfidstore.it

Next, all access label operations will only be performed for labels with this EPC number If you want to cancel the EPC match, just click Cancel in the drop-down menu and click the Select button. As shown below: 1.3.6 Access the label may return an error message In the process of access to the label operation, if the operation is not correct, there will be an error message, then we listed some common operational problems. Successful inventory but failed to access: 12 Eximia Srl www.eximia.it - www.rfidstore.it

The process of accessing a tag is actually divided into two steps, first by disk, and then accessed. The above prompt indicates that the label is successful, but the access operation is not possible In general, there are two reasons for this problem, one is the parameter settings are wrong, such as reading does not exist in the storage area, another reason is that the RF energy is not enough, access to the operating distance of the label is about the disk operating distance 60% to 70%, so if this is the case, please move the label closer to the antenna Access password is wrong: The cause of this problem, as described in the prompt, is that the access password is set incorrectly There is no operational label error: There are no labels available for operation in the RF area The meaning of the other return information, the user can refer to the document:uhf_rfid serial interface communication protocol _V2.38.pdf 13 Eximia Srl www.eximia.it - www.rfidstore.it

1.4 盘存和存取 ISO-18000-6B 标签 1.4.1 Access ISO-18000-6B tags ISO-18000-6B label operation and ISO-18000-6C label operation similar to the following figure: Every time you read the UID of the label once, the buzzer will be short. If the buzzer sounds slightly longer, then the reader starts the anti-collision function and simultaneously identifies multiple tags 1.4.2 Access ISO-18000-6B tags Access to the leaflet ISO-18000-6B label can only be accessed. Click the Access tab button to select the label to be operated in the UID list, as shown in the following figure: The next operation is relatively simple, the user can operate on their own. Note the following points: The access operation must operate the label of the currently selected UID Can read multi-byte tag data at the same time, the length is not limited You can write multi-byte tag data at the same time, the length is not limited. If an error occurs, the 14 Eximia Srl www.eximia.it - www.rfidstore.it

reader stops writing but has already written The incoming data will not be changed, and the reader will return the number of bytes successfully written Only one byte of card data can be locked at a time Only one byte of data can be queried at a time Locked byte operations are permanent and irreversible 1.5 RF parameter settings After successfully connecting the reader, we need to set some of the most basic RF parameters, the output power and spectral range The setting of the RF parameters is set in the reader settings -> RF parameters page, as shown in the following figure: 1.5.1 Set the RF output power RF output power refers to the antenna signal output RF signal strength. The unit is dbm 15 Eximia Srl www.eximia.it - www.rfidstore.it

The output power range is 0dBm - 33dBm. The default value is 30dBm (1 W). After this value is set, it will be automatically saved inside the machine, the machine is not lost after power failure 1.5.2Set the radio frequency spectrum specification In different areas, there are different requirements for radio frequency spectrum. There are two ways to set the reader's spectrum. Method 1: Use the default frequency of the reader. The default frequency of the reader can refer to the frequency parameter correspondence table in the communication protocol. The reader supports a frequency range of 865MHz - 868MHz, 902MHz - 928MHz. Use the drop-down boxes and buttons shown below to set the desired operating frequency range When setting the spectrum range, please note the following points: The starting frequency and end frequency can not exceed the range of RF specifications. 16 Eximia Srl www.eximia.it - www.rfidstore.it

The starting frequency must be less than or equal to the end frequency. Set the starting frequency and end frequency to the same frequency. The reader will work at constant frequency. This parameter is set, the reader's RF carrier will be in the restricted frequency range of random frequency hopping. The default RF spectrum specification is FCC (902MHz - 928MHz) Method 2: user-defined reader spectrum. The user uses three parameters to define the spectrum: the starting frequency, the frequency interval, the number of frequency points Note: In order to improve the anti-jamming performance, American Standard and European standard frequency band equipment selected hardware is different, it can not meet the compatible American standard, the European standard two bands 1.5.3 Set the antenna connection to receive Antenna connection to receive the function is: read and write tags before checking whether the port is connected to the antenna, if not connected, then notify the user antenna is not connected. Before using the user to open this function, through the interface shown below to view, set the interface of this function as shown below: The sensitivity of the antenna detection is set by the user. Antenna detection sensitivity is the antenna port return loss value (Return Loss), the unit is db. The greater the value, the better the impedance matching between the antenna and the port. In general, a normal antenna can set this threshold to 3-6 db. Ceramic antenna or handset antenna can reduce the sensitivity lower. If the return loss threshold is set to 0, it means that this function is disabled and the status of the antenna connection will not be detected before reading and writing the tag. If the antenna is not connected, read and write tags when the operation will return to the antenna is not connected to the error message 1.5.4 Measure the return loss of the current antenna port The return loss of the antenna port is detected at the interface shown below: 17 Eximia Srl www.eximia.it - www.rfidstore.it

1.6Other settings of the reader 1.6.1Monitor the operating temperature In the high-intensity continuous use of the reader, it will produce heat, the user can through the built-in temperature sensor to monitor the reader internal operating temperature, to avoid overheating (operating temperature of more than 65 degrees Celsius). If the temperature is too hot, you can stop reading and writing labels for a period of time The operating interface for monitoring the temperature is as follows: 1.6.2 Set the buzzer status The buzzer provides the user with the sound information of the reader's use status. The user can turn the buzzer off or set it to sound every time the label is saved. It can also be set to sound every time a label is read, but this will result in a reduction in the efficiency of multi-tag recognition. This feature is more Is applied in the test label or reader occasion The operation interface is as follows: It should be noted that the success of the self-test after the buzzer sound is not controlled by this 18 Eximia Srl www.eximia.it - www.rfidstore.it

setting. After setting, the state of the buzzer will keep the FLASH inside and outside the reader, after the power is not lost 2. Develop your own RFID application Users can use the demo program to operate most of the functions of the reader, but in the actual application environment, it is necessary to develop the user's own program The accompanying documentation: UHF_RFID serial interface communication protocol _V2.38.pdf provides a complete interface for operating the reader. This interface is based on serial communication, so regardless of the user's physical interface is RS - 232 or TCP / IP, the reader is to follow the definition of this interface Demonstration program provides an important function is the serial port transmission records, the user with the communication protocol documentation and demo program operation process of the actual serial data to compare, you can quickly grasp the contents of the communication protocol Select the lower right corner of the open serial port monitoring check box, all the uplink and downlink serial data will be recorded, as shown below (open the serial port monitoring, the software response speed will slow down, so usually should close the serial port monitoring.: 19 Eximia Srl www.eximia.it - www.rfidstore.it

Red information for the software to send the data, black information for the UHF module to return to the software data. Which manually send data function, for users to debug serial port command to use, it has automatically calculated check sum function. In addition, the accompanying documentation also includes the complete source code for this demo program for user reference, so that applications based on this handheld device can be quickly developed 20 Eximia Srl www.eximia.it - www.rfidstore.it