BalConIEs.
|
|
- Stewart Rodney Francis
- 5 years ago
- Views:
Transcription
1 BalConIEs Installation guidelines for balustrade cladding The following regulations and provisions must be observed when preparing and installing balustrade cladding using Trespa Meteon sheets: 防 The applicable technical building regulations. 防 The German ETB directive Bauteile, die gegen bsturz sichern (Building elements which protect against accidental falling). The various fixing options for Trespa have been tested with the applicable additional loads and stresses, in accordance with the German Einheitliche Technische Baubestimmungen (ETB - Uniform Technical Building Provisions) and in accordance with the latest technical developments. The results of these tests have been incorporated in the tables of dimensions. 防 When fixing Trespa as strips, the height of the strips must at least be equal to half the support distance. 防 Proof of stability must be submitted for balustrade structures of a drop height of 1 metre or more. 防 The standards and instructions for all parts of the balustrade structure and the anchoring facilities. When balustrade systems are used, the manufacturer s/ supplier s installation instructions also apply. 防 Balustrade heights and maximum permissible openings in the cladding material in accordance with the provisions of the applicable national building regulations. 防 Trespa Meteon panels must be installed such that they can still expand and contract. General installation guidelines Joints 防 Joint widths 2.5 mm per metre of panel length; and a minimum width of 10 mm for joints between two panels. If joint profiles are used, their body thickness must be considered as well Balconies rch. Renato Fornaciari, Italy code U2970 version
2 Fixing with blind rivets Fixing with aluminium or stainless steel blind rivets; available with painted heads in all Trespa Meteon colours. Only stainless steel blind rivets must be used for steel subframes. Special tool Balconies 防 Suppliers: For local suppliers of fixings and fastenings please consult Trespa UK td. 防 dimensions: Shank diameter = 5 mm. ength = blind rivet package thickness + 5 mm (always at least 16 mm). 防 Head diameter: 16 mm for blind rivets with painted heads. 防 Sliding points: Tighten the rivets using a special tool to keep them 0.3 mm free from the panel surface. Drill holes for sliding points using a stepped drill or a drilling template, so that the shank of the rivet is perfectly centred in the wider hole drilled. Note: use blind rivets and rivet tools of the same brand to ensure uniform dimensions. 防 Fixed point: Only one fixed point in the centre of the panel. Tighten the blind rivet on the fixed point without using the special tool. ll other fixing points are sliding points. Sliding point Fixed point Diameter of the hole in the in the panel subframe Fixed point 5,1 mm 5,1 mm Sliding point 10 mm 5,1 mm 防 Edge clearance of holes: t least 20 mm to the centre of the hole; maximum 20 x panel thickness. 防 The maximum permissible panel length is 3050 mm. Drill template Ø 5,1 mm Ø 10,0 mm
3 Fixing with balcony screws Fixing with stainless steel balcony screws with painted heads or cup-shaped washers and plastic caps, available in all Trespa Meteon colours. Or fixing with special stainless steel fasteners for balcony panels and accompanying aluminium sleeves; the sleeves are coated and are also available in all Trespa Meteon colours. Both methods are suitable for panel thicknesses of 8 mm and up. Sliding points Balcony screws 防 Supplier: For local suppliers of fixings and fastenings please consult Trespa UK td. 防 dimensions: Diameter: 5 mm length: total material thickness + 10 mm 防 Head diameter: s with painted heads: 16 mm 防 Sliding and fixed points: One fixed point in the panel centre; otherwise only sliding points. Diameter of the hole in the in the panel subframe Sliding point s with cover caps 5,1 mm 10 mm s with painted heads 10 mm 5,1 mm Fixed point 5,1 mm 5,1 mm Fixed point Sliding point Fixed point Balcony screws & balcony panel fasteners 防 Supplier: For local suppliers of fixings and fastenings please consult Trespa UK td. 防 dimensions: Diameter: 5 mm ength: at least total thickness of material package + 1 mm Head diameter: 12 mm 防 Sleeve dimensions: Diameter: 10 mm; head diameter: 16 mm 防 Sliding and fixed points: One fixed point in the panel centre; otherwise only sliding points. Diameter of the hole in the in the panel subframe Sliding point 10 mm 10 mm Fixed point 5,1 mm 10 mm 防 Edge clearance of holes: t least 20 mm to the centre of the hole Maximum 20 x panel thickness 防 The maximum permissible panel length is 3050 mm.
4 Fixing with clamps/welded metal lugs Fixing with clamps Clamps are used for panel thicknesses of 8 mm and up. 防 Clamps are screwed to the horizontal rails or vertical battens. 防 If the clamps are fixed to vertical battens, each panel has to be secured to prevent it from sliding out of position, for example by means of lock pins. 防 Minimum clamp depth 35 mm. 防 djust the distance between the clamp parts to the panel thickness taking into account dimensional tolerances and fixed EPDM gaskets. 防 eave minimum 2.5 mm/m free space between the clamp and the edge of the panel. 防 Sliding points: Sliding points are slotted holes in the section. 防 Fixed point: Only one fixed point in the centre of the panel; hole diameter = screw diameter. ll other fixing points are sliding points. 防 Edge clearance for clamps: maximum 20 x panel thickness. 防 Suppliers: For local suppliers of fixings and fastenings please consult Trespa UK td. Clamp depth Sliding point Fixed point Fixing using welded metal lugs Welded metal lugs can be used for panel thicknesses of 8 mm and up. 防 Metal lugs are welded to the horizontal rails or vertical battens. 防 eave minimum 2.5 mm/m free space between the clamp and the edge of the panel. 防 Sliding points: Diameter of the holes in the welded metal lugs = screw diameter + 5 mm = 10 mm (for a screw diameter of 5 mm). 防 Fixed point: Only one fixed point in the centre of the panel; hole diameter = screw diameter. ll other fixing points are sliding points. 防 Edge clearance of holes: at least 20 mm; maximum 20 x panel thickness.
5 Maximum spans and fixing centres for panels only secured via fixing points on the edges Only secure on the edges Panel Fixing Fixing centre thickness (mm) (mm) = 500 = Clamp or welded = 600 metal lug = 750 = 500 = Clamp or welded = 750 metal lug = 950 = 500 = Clamp or welded = 1000 metal lug = 1250 = / blind rivet / welded metal lug or clamp distance = Panel span; distance to the centre of the carrier profile (or strip) to the centre of the carrier profile (or strip) Clamps or welded metal lugs
6 Maximum spans and fixing centres for panels secured via fixing points on the edges and in the centre Secured both on the edges and in the centre Panel Fixing Fixing centre (mm) thickness (mm) 8 = 600 = 800 = = 600 = 1200 = 1200 = = 1500 = 1500 = /rivet distance = Panel span; distance from the centre of the carrier profile (or strip) to the centre of the carrier profile (or strip) For aesthetical reasons we recommend decreasing the fixing centres and panel spans listed by 5 to 10% for building heights of over 8 metres. We recommend decreasing these values by 10 to 15% for building heights of over 20 metres and that no 6-mm panels are used in this case. rch. Dipl.-Ing. Franz Friedreich, ustria
7 Fixing with profiles Trespa Meteon panels of panel thicknesses of 6 mm and up can be fixed with profiles on two or four panel sides. The profiles must offer static bearing support in a longitudinal direction. Fixing detail 防 Profiles: The profile dimensions must be adjusted to the panel thickness, taking into account dimensional tolerances and fixed EPDM gaskets. 防 Depth of groove in panel: minimum 20 mm. 防 Keep the edges of the panel at least 6 mm free from the profiles on three sides, enabling the panel to expand and contract. 防 Water drains: Water drains in lower horizontal rail by fitting slotted holes of 5 x 25 mm or drilling holes with an 8-mm diameter. Install two supports (minimum 5 x 50 mm) in the lower profile for every panel. 防 For optical reasons a metal H-section is to be used where two panels meet. Fixing detail Maximum panel spans and fixing centres for panels fixed on two sides Panel thickness (mm) Span (mm) = Maximum panel span in mm For aesthetical reasons we recommend decreasing the fixing centres and panel spans listed by 5 to 10% for building heights of over 8 metres. We recommend decreasing these values by 10 to 15% for building heights of over 20 metres and that no 6-mm panels are used in this case.
8 Maximum spans and fixing centres for panels fixed on four sides = always the short panel side in mm = always the long panel side in mm For aesthetical reasons we recommend decreasing the fixing centres and panel spans listed by 5 to 10% for building heights of over 8 metres. We recommend decreasing these values by 10 to 15% for building heights of over 20 metres and that no 6-mm panels are used in this case. Fixed on four panel sides Maximum fixing centres mm 8 mm korte short paneelzijde panel side () () long panel side ()
KEITH PANEL SYSTEMS FUNDERMAX- MAX EXTERIOR EXPOSED FASTENER PRESSURE EQUALIZED WALL SYSTEM
S Y S T E M D E T A I L S FUNDERMAX- MAX EXTERIOR EXPOSED FASTENER PRESSURE EQUALIZED WALL SYSTEM PAGE TITLE PAGE Table of Contents Fundermax Max Exterior Product Information Design and Installation Information
More informationRoof fastener. Perfectly thought out for every roof
Roof fastener Perfectly thought out for every roof 1 Welcome to the world of clever solutions Solutions for every roof In our production areas we produce all needed components for the sub construction
More informationEXPOSED FASTENING SYSTEM WITH SCREWS OR RIVETS
External EXPOSED FASTENING SYSTEM WITH SCREWS OR RIVETS Parklex Facade may be installed using mechanical fasteners, such as screws or rivets. The panels are attached to vertical battens. In the event that
More informationRIVETING Rivet types Solid rivets Solid rivets are used less and less. They have been replaced in many cases by welding or bonding.
10.1 Rivet types 10.1.1 Solid rivets Solid rivets are used less and less. They have been replaced in many cases by welding or bonding. Because of the large countersinking angle of 140 flat countersunk
More informationSLIDING DOORS DIRECT ROLLER
SLIDING DOORS Single door fixed to wall NFK s Direct Sliding Door system, for installation to a solid wall. Height adjustable track supports can be quickly mounted to a wall allowing the glass to pass
More informationRIVKLE Elastic. Fastener for noise and vibration decoupling applications
2300/11.02 RIVKLE Elastic Fastener for noise and vibration decoupling applications Contents RIVKLE Elastic Blind rivet nuts for noise and vibration decoupling applications Page The system 3 The principle
More informationPORCH COMPANY PVC PANEL AND DECKORATOR RAILING
PORCH COMPANY PVC PANEL AND DECKORATOR RAILING Installation Instructions +1-615-730-8067 porchstore@porchco.com www.porch-store.com Assumption: Your deck is built, your decking is down and your 4x4 core
More informationDoor Hinges Drill-in Hinges
Drill-in hinge StarTec Frame part For timber lining frames For rebated doors Maintenance-free friction bearing To use in combination with receiver Max. door weight: 40 kg Knuckle: Ø15 mm Drilling bit Ø7.2
More informationInterior Equipment/Shop Fittings
Interior Equipment/ Contents Room and Frontwall Systems DIFLEX Adjusting foot for raised floors Hook-in profile Hook-in profile Eilox SHOPTEC Shopfitting system Wall channel Bracket Column Accessories
More informationC11.16 CHRONO ACCESSORIES C11 SIDE HUNG WINDOWS
C11 SIDE HUNG WINDOWS CHRONO ACCESSORIES 01.12.2018 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com CONTENTS 1. Window stays....03
More informationPOOL ENCLOSURES LEIA & ALVA. Assembly manual
POOL ENCLOSURES LEIA & ALVA Assembly manual Rev. 07.2017 PARTS LIST Parts for rail installation: Rail Síncsavar screw 1 Plastic Síncsavar anchor 10 50 2 Rail Síncsavar connector 3 Arrest Síncsavar wedge
More informationTable and Furniture Base Fittings Plinth Adjusting Fittings
Adjusting screw with M8 or M thread Rigid, for glide inserts, steel thread Finish/Colour: Black, thread galvanized Version: With acceptance Ø30 mm Thread M8 650.22.381 M 650.22.382 Packing: 1 or 0 pcs.
More informationPull Handles Fixing Types. One-sided installation. Installation per pair. Wood, plastic profiles, 2-3 chamber aluminium profiles
Pull Handles Fixing Types One-sided installation Wood, plastic profiles, 2-3 chamber aluminium profiles Installation per pair Wood, plastic profiles, 2-3 chamber aluminium profiles 204 HEWI Hardware Technology
More informationFUSION JULIETTE BALCONIES FITTING INSTRUCTIONS
FUSION JULIETTE BALCONIES FITTING INSTRUCTIONS The Richard Burbidge FUSION Juliette Balcony System comprises a combination of timber and aluminium rails, glass infill panels and brackets designed for use
More informationaluminium profile system
aluminium profile system 63 AME System aluminium profiles overview series profiles introduction 80x80 x80 x80/180 x Aluminium profiles are provided with longitudinal grooves which can be used in conjunction
More informationK15.13 FACE FIXED DOOR HINGES K15 DOORS
K15 DOORS K15.13 01.02.2017 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com CONTENTS 1. General... K15.13.03 2. 2-part hinge...
More informationFaçade System Trimoterm FTV INVISIO
Façade System Trimoterm FTV INVISIO Façade System Trimoterm FTV INVISIO - Technical Document EN Version December 0 TABLE OF CONTENTS Technical description of the Facade system with Hidden Fixing FTV INVISIO.
More informationWall mounting with holding profile
B Main profile C Edge profile D Wall spacer E Heradesign acoustic panel Edge distance max. 250 mm c Centre distance of basic section (see table) B max. 600 mm or 625 mm a Centre distance of spacer (see
More informationInstallation Manual FLUSH MOUNT - Shingle, Slate,etc. Questions? Call Us! +1 (800)
www.trasnowandsun.com S Installation Manual FLUSH MOUNT - Shingle, Slate,etc. At TRA Snow and Sun we engineer and layout each project upon request free of charge. Just give us the project details and we
More informationInstallation of HORIZONT and HORIZONT HIGH pool enclosures
Installation of HORIZONT and HORIZONT HIGH pool enclosures Rev. 19.10.2017 PARTS LIST Parts for rail installation: Rail screw 6 x 60 Plastic anchor 10 x 50 Rail connector Arrest wedge [R-L] Pop rivet 4
More informationInstallation Instructions
Installation Instructions Alpha SolarSmart On Roof Kits for the Installation of Alpha Solar Collectors onto Tile and Slate Type Roofs For Technical help or for Service call... ALPHA HELPLINE Tel: 0 77
More informationC13.11 HANDLES AND CONNECTION PIECES C13 SIDE HUNG WINDOWS
C13 SIDE HUNG WINDOWS C13.11 HANDLES AND CONNECTION PIECES 01.05.2014 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com CONTENTS
More informationNewTechWood Screening Installation Guide. v au
NewTechWood Screening Installation Guide v20180724au IMPORTANT: Read All Sections Before You Start For the most up to date information, please visit our website @ www.newtechwood.com.au NewTechWood screening
More informationFixing types for pull handles
Fixing types for pull handles One-sided installation Timber, Plastic profiles, 2-3 chamber aluminium profile Double-sided installation Timber, Plastic profiles, 2-3 chamber aluminium profile Please consult
More informationSIG-032-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY III LUMINAIRE ARM (SEE CONTRACT) 6'-0", 8'-0", 10'-0" NOMINAL SPREAD
Michigan Department of Transportation 6'-0", 8'-0", 10'-0" NOMINAL SPREAD (SEE CONTRACT) LUMINAIRE ARM (SEE CONTRACT) POLE CAP 1'-6" (6'-0" ARM) 1'-10" (8'-0" ARM) 2'-0" (10'-0" ARM) NOMINAL RISE 2.38"
More informationSUMMARY. V-Lock SYSTEM BASIC ELEMENTS ACTUATORS. P V-Lock GENERAL INTRODUCTION 2. P V-Lock FIXING ELEMENTS 10 SUMMARY. P V-Lock ADAPTORS 17
SUMMARY A3 V-Lock SYSTEM P V-Lock GENERAL INTRODUCTION 2 BASIC ELEMENTS P V-Lock FIXING ELEMENTS 10 P V-Lock ADAPTORS 17 SUMMARY P PROFILES 28 P V-Lock ACCESSORIES AND SPARE PARTS 32 1 A3 GENERAL INTRODUCTION
More informationSLIDING GATES BRUNDLE
SLIDING GATES BRUNDLE 32 BRUNDLE TOOTHED GATE RACK & ACCESSORIES TO BE WELDED TO GATE. GALVANISED OR SELF COLOUR IN ROLLED STEEL FOR GATES UP TO 1800KG Rack 22 x 22 H Art L H T L T Self Colour Self Colour
More informationInstallation Instructions
Installation Instructions 200 Series Curtainwall 3056 WALKER RIDGE DR. NW, SUITE G WALKER, MI 49544 800-866-2227 dependable@tubeliteinc.com Revised April 2014 dependable@tubeliteinc.com Page 1 TABLE OF
More informationMANET. Technical manual for ordering and installation. Single-point fixings for interior applications
MNET Technical manual for ordering and installation Single-point fixings for interior applications DORM MNET Glass design system MNET ONEPT MNET OMPT Sets Today s approach to office design tends to be
More informationVertical Slider Section Detail
Vertical Slider Section Detail PRODUCT GUIDE Main & Bead Profiles 128 42 69 VS01 - Outer frame 150 139 210 189 60 52 52 52 48 30 42 60 18 72 90 18 60 VS02 - Cill VS14 - Cill 18 VS03 - Top Sash VS04 - Standard
More informationInstallation Instructions - Model V4JSD 1
Installation Instructions - Model V4JSD 1 Support Assemblies: Parts list: (Note see enclosed cut sheet for quantities and dimensional information) A vertical structural member (1 ½ x 1 ½ modular frame)
More informationATI Evaluation Service A Division of Architectural Testing Certification Services
ATI Evaluation Service A Division of Architectural Testing Certification Services Subject to Renewal: 10/13/2016 Issued: 12/17/2014 Visit www.ati-es.com for current status Revised: 06/05/2015 Page 1 of
More informationMounting a BalanceBox 400 to a brick wall
Unpack the BalanceBox 400 and remove the Wall frame cover and its bag of screws. Slide the cover out at the top. NOTE: the cover is NOT included with the BalanceBox 400H LOCK SCREW HOLE MOBILE STAND MOUNTING
More informationKitchen Fittings Hanging Cabinets and Accessories
Cabinet hanger Knock-in version, load bearing capacity 130 kg/pair Depth adjustment Finish: Galvanized Concealed mounting of cabinet hanger behind the rear panel (Min. 16 mm free space required) Mounting
More informationSingle-point fixing serie S32/35
MNET Single-point fixing Single-point fixing serie S2/ The basic component within the MNET system is the single-point fixing a basic rather than cylindrical bore in the glass, has a tapered countersunk
More informationMaterial Packing Brown Grey Pine Black White
RTA Connectors Minifix Zinc alloy For housing: 12 or 18 Bolt hole: Ø 7 or 8, depending on choice of connecting bolt Drilling distance B: Distance from centre of Minifix housing to shelf front edge (24
More informationInstallation Instructions Student 101 Fume Cupboard
Installation Instructions Student 101 Fume Cupboard Refer drawing on next page 0. If your fume cupboard is supplied with a flatpack bench frame, see step1. If your fume cupboard will be mounted on an existing
More informationInstallation manual. For setting in concrete/on base plates - Panel height 1830
1 Aluminium fencing and drive-in gates Installation manual For setting in concrete/on base plates - Panel height 1830 Aluclos system components: U10 Connecting U-bracket 1900 mm CL18/CL18.XL Half-height
More informationCURVED ROOF ASSEMBLY INSTRUCTIONS ATTACHED VERANDAH. Your supplementary guide to building an ATTACHED CURVED ROOF VERANDAH or PATIO BEFORE YOU START
ROOF ATTACHED VERANDAH ASSEMBLY INSTRUCTIONS Your supplementary guide to building an ATTACHED ROOF VERANDAH or PATIO This set of instructions should be used in conjunction with the Stratco instruction
More informationTECTUS. The completely concealed hinge system
TECTUS The completely concealed hinge system It s still design even if there s nothing to be seen! TECTUS This Latin word for concealed signifies SIMONSWERK s newly developed, completely hidden hinge system.
More informationNEWS Part. N /0 MINITEC NEWS
NEWS 2009 Part. N 95.0423/0 MINITEC NEWS 2009 1 TABLE OF CONTENT INTRODUCTION CONTENTS 3 END CAP Z WITH HAMMER TAPS 3 END CAP 45X45 VA 4 ANGLE 25 GD-Z 4 ANGLE 45X90 GD-Z 5 ANGLE 90 GD-Z 5 HINGE 19 S 6
More informationno mm no Dividers with scriber 150 mm NEW Square wedge-shaped knife edges on the length side
Summer Promotion valid until 30.06.2013 all quoted prices are incl. VAT for deliveries to EU countries to customers with valid VAT-no. and for deliveries in non EU member countries the VAT is not applicable
More informationWADE 2-1. Universal Carrier. Exclusive Features of 400 Series Universal Carrier for Lavatories, Urinals, Drinking Fountains.
Universal Carrier Exclusive Features of 400 Series Universal Carrier for Lavatories, Urinals, Drinking Fountains. The 400 series carrier accommodates most urinal, water-cooler or hanger plate lavatory
More informationPole Mount Installation Manual
Pole Mount Installation Manual Thank You for Choosing AIMS Power! 1. AIMS Power is a leading supplier of solar products, specializing in PV mounting systems. We ensure our products are manufactured to
More informationBC-SERIES Screw-Jack Pedestal for Creative Design. Specifications text. Menu. Page 1/7
Specifications text BC Series Screwjack Pedestal 3rd Generation Menu Introduction of the BC series 1 Pedestal 1.1 Head 1.2 Base 2 Sleeve 3 Tabs 4 Lock 5 Slope corrector PH5 6 Slope corrector BC-PH5 7 Reverse
More informationFEET, WHEELS, FLOOR FASTENINGS, SUPPORTS
SYSTEM COMPONENTS FEET, WHEELS, FLOOR FASTENINGS, SUPPORTS s t r oppu S, s gn i n e t s af r oo l F, s l eehw, t e ef FEET, WHEELS, FLOOR FASTENINGS, SUPPORTS 136 MINITEC PROFILE SYSTEM BASE AND TRANSPORT
More informationAdjustable Feet Castors Accessories for Floor Elements
Adjustable Feet Castors Accessories for Floor Elements Products in this section Levelling Knuckle Feet Threaded spindles for infinite height adjustment Metal or plastic foot plate Knuckle Feet X Compatible
More informationAssembly Instructions
Selling Station Assembly Instructions View from above without top A B C D Rounded finished corners on A & D Square unfinished 3-sides on B & C Selling Station Components (2) 2' x 6' Side s Have a channel
More informationComponents made of special materials. Floor Elements for Profile St Profile KH. Fastening Elements for Profile KH
Profile Fastening Elements for Profile Floor Elements for Profile Profile KH Fastening Elements for Profile KH Components made of special materials Products in this section Profile 8 x eel profile that
More informationSIG-030-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY I LUMINAIRE ARM 6'-0", 8'-0", 10'-0" NOMINAL SPREAD (SEE CONTRACT) POLE CAP
Michigan Department of Transportation 6'-0", 8'-0", 10'-0" NOMINAL SPREAD (SEE CONTRACT) LUMINAIRE ARM (SEE CONTRACT) POLE CAP 1'-6" (6'-0" ARM) 1'-10" (8'-0" ARM) 2'-0" (10'-0" ARM) NOMINAL RISE 2.38"
More informationClopay Models 835/837 Sliding Door System Installation Guide
Clopay Models 835/837 Sliding Door System Installation Guide The aim of this instruction is to guide you through the process of construction and fitting of Sliding Doors. Due to the number of sizes available
More informationFireball Fab Welded Baluster Insert Panel System Installation Instructions
Fireball Fab Welded Baluster Insert Panel System Installation Instructions Prior to construction, check with your local regulatory agency for special code requirements in your area. Common railing height
More informationCembrit Patina. Cembrit Cover. Cembrit Solid. Cembrit Transparent
Rainscreen Cladding Your choice. In addition to the range of colours and shades, Cembrit cladding boards are available in four compositions, each with distinctive performance and characteristics. Cembrit
More informationTECTUS - New Versions. New Versions. The completely concealed hinge system
TECTUS - New Versions New Versions The completely concealed hinge system index te 240 3d up to 40 kg 6 te 340 3d up to 80 kg 7 TE 540 3D up to 120 kg 8 TE 640 3D up to 200 kg 9 TE 540 3D A8 up to 100 kg
More informationVerge Flashing. Verge Flashing. Only use if flashings requirements can be site measured before ordering. Verge Clip
Tolerance Detail (recommended) Verge Closure Verge Channel Verge Clip Verge Flashing VERGE CHANNEL RIVETTED TO EUROSEAM AT APPROX 400MM CENTRES USING 4.8 X 12MM RIVETS. NB: DO NOT RIVET AT HALTER POSITION
More informationPrecision Steel Car s 100 T Steel Coil Car
Precision Steel Car s 100 T Steel Coil Car Precision Steel Car www.precisionsteelcar.com info@precisionsteelcar.com Paul Vernon: (513) 571-5739 Revised 4/30/2009 Contents of Kit Main Tube Side Frame 2
More informationHENDERSON. Securefold R-Loc Non-Mortice 100kg. Fitting Instructions for top hung exterior folding doors with NON-MORTICE HINGES SYSTEM CAPACITY
1 HENDERSON Diagram 1 TRACK FIXING (NOT BY PCH) Securefold R-Loc Non-Mortice 100kg Fitting Instructions for top hung exterior folding doors with NON-MORTICE HINGES SYSTEM CAPACITY Maximum leaf height-
More informationProducts for fixing to Steelwork and Decking
Products 8.0 Beam Clamp - Single Support 8.1 Universal Joint for any variable Angle Adjustment 8.2 Beam Clamp TCS for Header Rails 8.3 Beam Clip for Cross Support/ Dimensioning of Bolts 8.4 Beam Clip for
More informationInstallation Guide 2016
Installation Guide 2016 BUILDERS EDGE INSTALLATION GUIDE This guide will show you the products of the Builders Edge family. It provides specific installation steps and application details. Our main goal
More informationDUTCH GABLE FREESTANDING CARPORT
DUTCH GABLE FREESTANDING CARPORT STRATCO OUTBACK ASSEMBLY INSTRUCTIONS. Your complete guide to building a FREESTANDING Outback DUTCH GABLE CARPORT BEFORE YOU START Carefully read these instructions. If
More informationPREASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS
PROFILE SYSTEM PRE-ASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS s r ood gni d i l s dna gni t f i l r o f s t neme l e de l bme s s a - er P PREASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS MINITEC
More informationFortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards.
Installation Instructions for FortressCable V-Series Cable Stair Panel System with UB-05 With ngle dapter and Fe Posts It is the responsibility of the installer to meet all code and safety requirements,
More informationInterior Equipment, Shop Fittings
Interior Equipment, Häfele, the brand you can trust. The innovator of functionality. Contents Room and Frontwall Systems DIFLEX Adjusting foot for raised floors Hook-in profile Eilox SHOPTEC Shopfitting
More informationLift-off hinge. Rising hinge. Standard hinge. Heavy duty hinge. Parliament hinge. Spring hinge. Double action spring hinge. Concealed mortise hinge
Door Hinges Contents Butt hinges Lift-off hinge Rising hinge Standard hinge Heavy duty hinge Parliament hinge Spring hinge Double action spring hinge Concealed hinges Concealed mortise hinge Pivot door
More informationSiding Components. Installation Guide
Siding Components Installation Guide 2016 MID-AMERICA SIDING COMPONENTS INSTALLATION GUIDE This guide will show you the products of the Mid-America Siding Components family. It provides specific installation
More informationNX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP
6-1/4 HANDRAIL W/ VINYL HANDGRIP TYPICAL ASSEMBLY 5 2 BUTT JOINT 12 10 9 1 8 11 6 3 7 4 BUTT JOINT COMPONENT LIST 1 LEFT RETURN 7 UPPER IMPACT ABSORBER 2 RIGHT RETURN 8 LOWER IMPACT ABSORBER 3 OUTSIDE
More informationConnecting elements for connecting hard-pressed steel with aluminium/steel
Connecting elements for connecting hard-pressed steel with aluminium/steel 1. The Tuk-Rivet punched rivet system The rivet comprises a rivet head, a shank area, one or more shank grooves and the cutting
More informationM4 Hex Nut [ ] M4 T-Nut 20 [20-044] Appx. 1. 3mm. 20 Series profiles (1 per hole) (1 per hole) Ordering Information
Handles & Light Duty PA 20 1 Assembly of Hinge M4x8 FHCS [24-208-4] M4 T-Nut 20 [20-044] M4 Hex Nut [24-706-4] 60 300-0 PA 20 on panel 2 Hinge positions 3-4 Clearance dimensions 5 Range of swing FOR M4
More informationINSTALLATION INSTRUCTIONS TRI-ROOF. energy for a better world
energy for a better world INSTALLATION INSTRUCTIONS TRI-ROOF The flexible roof integration system Compatible for framed module types* Simple exchange of modules Replaces existing roofing Special profiles
More informationAPPENDIX FENCE GENERAL NOTES
APPENDIX FENCE GENERAL NOTES 1. Fabric: 9 gage, 2" mesh, knuckle top and bottom, placed on the outside of posts, single fabric width for the entire height. 2. All fencing to be standard galvanized finish.
More informationBAKA Protect Serie 2000 / Protect. BAKA Protect Series 2000 / The adjustable hinge system for timber entrance doors
Protect Serie 2000 / 4000 Protect BAKA Protect Series 2000 / 4000 The adjustable hinge system for timber entrance doors index BAKA Protect 2D BAKA Protect 2010 2D two-dimensionally adjustable up to 120
More informationMEFA mounting accessories
MEFA mounting accessories Mounting accessories Base plates Page 5/2 Double holder Page 5/4 Height-adjustable suspensions Page 5/5 Pendular bolt joints Page 5/6 Trapeze hanger Page 5/7 Threaded hooks, distance
More informationFixings & Fastenings. Bright Zinc Plated, Galvanised & Stainless Steel. Lockinex. ea i, ea u i
Fixings & Fastenings Bright Zinc Plated, Galvanised & Stainless Steel Lockinex ea i, ea u i INTRODUCTION The Lockinex Range of Fixings & Fastenings are manufactured in Bright Zinc Plate, Hot dipped galvanised
More informationIIHS Side Impact Outrigger
IIHS Side Impact Outrigger Assembly Procedure Base Assembly (14.3 lbs) The base assembly consists of a ¼ thick steel plate, a ¼ thick piece of polyethylene, and mounting fixtures for the upper and lower
More informationResysta 6 and 4 Flat Board Siding System Assembly Installation Guidelines
Resysta 6 and 4 Flat Board Siding System Assembly Installation Guidelines NOTE: Proper planning of the siding layout is essential for ease of installation of siding boards and siding components. Thoroughly
More informationAssmann Corporation of America TANK INSTALLATION AND USE GUIDELINES FOR BULK STORAGE TANKS
Assmann Corporation of America TANK INSTALLATION AND USE GUIDELINES FOR BULK STORAGE TANKS General Information Assmann polyethylene storage tanks are manufactured to give you the toughest, most reliable
More informationSolarMount (E)volution
SolarMount (E)volution SOLARMOUNT (E)VOLUTION: THE BEST JUST GOT BETTER. Engineering, Excellence, and Ease. Performance Engineered for versatility and reduced installation time, SolarMount (E)volution
More informationSLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE
Set A Set B PFD30 Fire Door Kit FITTING INSTRUCTIONS For use with 44mm thick doors only For Single and Double doors IF INSTALLING A TOUCH LATCH, PLEASE READ THE CORRESPONDING FITTING INSTRUCTIONS FIRST
More informationVEKA GROUP PATIO DOOR PATIO DOOR PATIO DOOR UNCONTROLLED DOCUMENT AUTHOR PHIL GREGORY VEKA _IMAGINE PATIO_INSTALLER AID
VEKA GROUP VEKA _IMAGINE PATIO_INSTALLER AID UNCONTROLLED DOCUMENT VEKA GROUP USE OF THIS MANUAL Guidelines Advice & General Information. Although it is possible to manufacture a five metre four pane patio
More information400A 40113V, 401A 40120V, & 401AL 40120VL ALUMINUM VERTICAL 4000 LB LIFT INCLUDES SCREW LEG ASSEMBLY INSTRUCTIONS
12/11/07 PAGE 1 OF 12 400A 40113V, 401A 40120V, & 401AL 40120VL ALUMINUM VERTICAL 4000 LB LIFT INCLUDES SCREW LEG ASSEMBLY INSTRUCTIONS Thank you for purchasing our product! *Please read these instructions
More informationWG-4 Wall Guard Installation Instructions
WG-4 Wall Guard Installation Instructions Architectural Products Division Step 1: Determine top of wall guard and snap a chalk line 1/8 below to locate top of aluminum retainer, see fig 1. Store material
More informationFaçade CUT-TO-SIZE FAÇADE STRIPS APPLICATION IN OVERLAP ON WOODEN SUPPORTING STRUCTURE APPLICATION INSTRUCTIONS 1 1. GENERAL
Façade CUT-TO-SIZE FAÇADE STRIPS APPLICATION IN OVERLAP ON WOODEN SUPPORTING STRUCTURE APPLICATION INSTRUCTIONS 1 1. GENERAL These application instructions are specifically intended for the fastening of
More informationQuill Stop V2 Installation Guide 11/16/2014
Thank you for purchasing the Quill Stop for the Sieg X3 (Grizzly G0463) and SX3 (Grizzly G0619) mills. Your feedback is always appreciated. Please email questions and comments to gregpriest@cox.net. What
More informationS48-L12-SC AND G48-L12-GC STEEL PORTA-DOCK S82 SC 6 X 12 PLATFORM AND G82 GC 6 X 12 PLATFORM
PAGE 1 OF 6 PORTA-DOCK, INC. S48-L12-SC AND G48-L12-GC STEEL PORTA-DOCK S82 SC 6 X 12 PLATFORM AND G82 GC 6 X 12 PLATFORM Thank you for purchasing our product! *Please read these instructions and follow
More informationInstallation Manual. Solid Plastic Toilet Partitions. IN CANADA & AREAS OTHER THAN U.S.A.: IN THE U.S.A.:
Installation Manual Solid Plastic Toilet Partitions Toilet Partitions & Lockers IN THE U.S.A.: Hadrian Inc., 7420 Clover Avenue, Mentor, OH 44060 Telephone: 440-942-9118 Fax: 440-942-9618 U.S. toll free
More informationCable Cutter Square. 25 Tape Measure. Chalk Line Level Loctite 242 Blue
ATLANTIS RAIL Contact Information: Atlantis Rail Systems 70 Armstrong Road 3900 Civic Center Drive Plymouth, MA 02360 North Las Vegas, NV 89030 (800) 541-6829 or (508) 732-9191 (508) 732-9798 www.atlantisrail.com
More information50948-RHN Putney. 06 January This document includes: Aluminium strip/ sheet coverings/ flashings 1. Code Section Revision Dated
50948-RHN Putney 06 January 2018 This document includes: Code Section Revision Dated H72 Aluminium strip/ sheet coverings/ flashings 1 Table of Contents Title H72 Aluminium strip/ sheet coverings/ flashings
More informationThe Safe Solution for Stainless Steel Balustrade Systems
M E R G I N G S A F E T Y W I T H S T Y L E The Safe Solution for Stainless Steel Balustrade Systems KEE STAINLESS is the most exclusive product in the Kee Safety handrail and balustrade product range.
More informationMarch weeks. surcharge for
March weeks valid until 31.03.2012 all quoted prices are incl. 19% VAT for deliveries in the EU countries to customers with a valid VAT-no. and for deliveries in not EU member countries the VAT is not
More informationSelection BASIC LINE BASIC LINE PLUS VARIO LINE SERIES TUBE LINE STEEL LINE
PLUS 30 for cable carriers Support trays page 304 PLUS Guide channels page 305 RCC Rail Cable Carrier page 309 ECC Emergency Cable Carrier page 30 Strain relief devices page 3 Assembly profile bars page
More informationCRYSTEEL S. this manual must be included with the vehicle after completing the installation.
Website: www.tbei.com E-mail: sales@tbei.com CRYSTEEL S Grain Tipper mounting and operating instructions this manual must be included with the vehicle after completing the installation. Web Site E-Mail
More informationMX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP
6-1/4 HANDRAIL W/ VINYL HANDGRIP TYPICAL ASSEMBLY 5 2 BUTT JOINT 12 10 9 1 8 11 6 3 7 4 BUTT JOINT COMPONENT LIST 1 LEFT RETURN 7 UPPER IMPACT ABSORBER 2 RIGHT RETURN 8 LOWER IMPACT ABSORBER 3 OUTSIDE
More informationSheet Steel Facts. Most common head design for self-drilling, self-tapping screws.
Sheet Steel Facts Fastener Guide for Sheet Steel Building Products August, 2003 Fastener Materials Fasteners are manufactured from several materials and coatings. For the purpose of this fact sheet, the
More informationBEST PRACTICE GUIDE. Socket Bases. Working with Concrete Slabs
Working with Concrete Slabs When working with concrete slabs the barrier protection can be erected in three ways - with socket bases, adjustable slab edge brackets and multi slab clamps. Socket Bases 1
More informationMay 14, Installation Manual
May 14, 2012 Installation Manual Contents MAG TRACKER Components...1 Mount Installation...7 Module Installation & Grounding...11 Maintenance...14 Warranty......14 Contact Information......14 May 14, 2012
More informationsalto safe 4028 A12 Turn-tilt windows
A12 Turn-tilt windows salto safe 4028 01.09.2013 Waregemstraat 5-9870 Zulte - Belgium - T. 32 9 388 88 81 - F. 32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com salto safe 4028 Contents 1. General
More informationHow to Install Custom Real Wood and Faux Wood Blinds
Before you begin your installation: READ ALL INSTALLATION INSTRUCTIONS! Make sure that you have all tools and hardware needed for installation. Check the installation surface (wall, ceiling, or window
More informationRoller Guides C-Rail Systems Linear Guide Systems Ball-Bearing Guide Bushes Ball-bush block guides Shafts Accessories for Linear Slides
Roller Guides C-Rail Systems Linear Guide Systems Ball-Bearing Guide Bushes Ball-bush block guides Shafts Accessories for Linear Slides Application example linear systems, drives and accessories 1 2 3
More informationTrack Rack. * Track Racks are not lockable
The Track Rack s unique staggered, sliding hook design creates the greatest parking efficiency while still providing easy access to any particular bike. When adding or removing a bike to the rack, simply
More informationFischerTHERM plusdach The Sandwichelement with the special something
The Sandwichelement with the special something Contents Page General Product Range 4 Fasteners 5 Secure fastening 7 Assembly 8 9 Details 0 References 4-5 FischerProfil 05 FischerTHERM plusdach The first
More information