1 Acousti-Seal Encore Paired Panel

2 OPERATING AND MAINTENANCE INSTRUCTIONS FOR OPERABLE WALL SYSTEMS MODELS: ENCORE PAIRED PANEL, 932, 912 Safety Precautions Clear path of partition before moving panels Raise all foot bolts and bottom seals before moving panels Close and latch all pass doors before moving panels Do not tow panels by the bottom seal handle Move at a walking pace-do not run, do not push and let go of panels Keep hands and fingers from between panels Do not force the panels into the stacked position Operating Instructions Step 1: Clear Path of Obstructions Before moving the panels, make sure the path is free of all obstructions like tables, chairs, carts, extension cords, or other electrical cables. Also check for open doors, loose carpet or flooring or any fixtures such as track lighting that may interfere with movement of the panels. If the panels are stored in a pocket, be sure the pocket doors are in their full open position. Step 2: Remove Panels from Stack Remove the panels from the stack area in pairs. Facing the stack, grasp the pair of panels closest to you by both edges at about shoulder height. Pull the panels toward you until you are the distance of one panel but not past the beginning of the guide rail (if applicable). Facing the edge of the panels opposite the hinge, open the pair of panels as you would open a book and gently push flat. The panels must be flat before moving past the beginning of the guide rail (if applicable). Step 3: Moving the Panels in the Opening Push the panels, one pair at a time from the rear, watching both sides and in front while they are in motion. Move the panels at a walking pace; do not run, and do not push the panels and let go. CAUTION: Be careful not to get your hands, clothing or anything else caught between the panel and another panel, jamb or fixed wall. If your partition has cable operated bottom seals, do not use the handle to tow the panels. 1

3 Step 4: Setting Up the Partition Automatic 2-Inch Bottom Seals (Non-SureSet ) Move the first pair of panels to the end of opening. Be careful not to slam the panel into the wall or wall jamb. The bottom seal in the first panel extends from the front of the panel and will be the first part of the panel to contact the jamb. Align the panel s and push them firmly against the jamb. The bottom seals will move back and down against the floor and will now extend from the back of the pair of panels. Move the remaining panels into the opening, except for the final closure panel(s). Align each pair of panels with the preceding panel and push them together. The first panel of each pair will slide over the bottom seal extending from the back of the previous panel, causing both bottom seals in the pair to move back and down against the floor. When the last panel with a bottom seal is in place, the seal should be flush with the back of the panel. If your partition has a pass door, it will have adjustable fixed sweeps. If the pass door is in the first panel of the pair, the following panel may have a manually operated seal. To set the seal in this panel, follow the procedure outlined in the next section. You may have automatic bottom seals on either side of the pass door. If your partition has automatic bottom seals in the panels following the pair containing the pass door, the first bottom seal will extend from the front of the panel just like the panel positioned against the jamb. SureSet Automatic 2-Inch or 4-Inch Bottom Seals Move the first pair of panels to the end of opening. The automatic top seal in the first panel extends from the front of the panel and will be the first part of the panel to contact the jamb. Align the panels and push them firmly against the jamb. The top seal will move back and up against the track soffit for both panels in the pair. The automatic top seal holds the panels in position at this point. The bottom seals in the first pair of panels will remain up until the second pair of panels are brought out. Take care to align the activator bar protruding from the lead edge of the second pair of panels with the push bar receiver protruding from the trail edge of the first pair of panels. Misalignment will result in damage to the astragal and edge of the panel being activated. The bottom seal of the first pair of panels is activated, dropping down to the floor, by firmly pushing the second pair of panels into it. This process will be repeated for all pairs of panels having automatic seals in the opening. If your partition has a pass door, it will have waist high manual, crank operated, bottom seals in the panel legs as well as the door itself. The pass door panel and leg bottom seal operators are accessed through the hinge edge of the door and each edge of the door opening. 2

4 CAUTION: Before setting the seals in the pass door panel, position and set the seals in the panels on both sides of the pass door. Cable Operated 2-Inch Bottom Seals (Non-SureSet ) Move the first pair of panels to the end of the opening. Align the panels and push them firmly against the jamb. Some panels will have a bottom seal handle located on the face of the panel, while other panels will have a bottom seal handle located in the edge of the panel. Grasp the bottom seal operator handle. Hold the panel with one hand, and with the other hand pull the handle to take up any slack in the cable, then pull firmly to release the bottom seal. Depending on the configuration of your panels, the bottom seals may operate simultaneously in both panels with a single operator handle. In other configurations, the seals in each panel must be set individually. After setting the bottom seals, return the handle to its original position before setting up the next panel. Do not let go of the handle and allow it to snap back into the panel. Move the remaining panels into the opening, except for the final closure panel(s). Align each pair of panels with the preceding panel and push them together. Set the bottom seals in each pair in the same manner. If your partition has a pass door, it will have bottom seals in each leg as well as in the door itself. Before setting the seals in the pass door panel, position and set the seals in the panels on both sides of the pass door. Crank Operated 2-Inch Bottom Seals (Non-SureSet ) Move the first pair of panels to the end of the opening. Align the panels and push them firmly against the jamb. Insert the removable bottom seal operator handle into the operator hole located either in the edge or on the face of the panel. Rotate the handle counter-clockwise to lower the bottom seal. Remove the handle after the seal is lowered completely. Except in special situations, the bottom seals will operate simultaneously in both panels with a single operation. In some special configurations, the seals in each panel must be set individually. Move the remaining panels into the opening, except for the final closure panel(s). Align each panel with the panel in front of it and push them together. Set the bottom seals in each panel in the same manner. SureSet Crank Operated 2-Inch or 4-Inch Bottom Seals Move the first pair of panels to the end of the opening. The automatic top seal in the first panel extends from the front of the panel and will be the first part of the panel to contact the jamb. Align the panel and push them firmly against the jamb. The top seal will move back and up against the track soffit for both panels in the pair. The automatic top seal holds the panels in position at this point. Next insert the removable bottom seal operator handle into the operator hole located in the trail edge of the panel. Rotate the handle counter-clockwise until it stops to lower the bottom seals. Remove the handle after the seals are lowered completely. Move the remaining panels into the opening, except for the final closure panel. Align each panel with the panel in front of it and push them together. Set the bottom seals in each panel pair in the same manner. 3

5 Step 5: Make Final Closure Expandable Panel An expandable panel has a crank-operated nose that expands up to 6-inches, 9 inches or 18 inches to close the opening. Expandable panels may close against a jamb, a pocket door, another panel or some other meeting surface. Position the expandable panel in the opening and insert the removable crank. Turn the crank in the direction indicated to extend the nose against the meeting surface. Do not over-extend the expandable nose. Excessive pressure does not improve acoustical performance but may damage the fixed wall. If your expandable panel has a manually operated bottom seal, you must set the bottom seal after the nose is extended to prevent possible seal or mechanism damage. If the expandable is hinged to another panel, they are unfolded and placed in the opening in the same manner as other pairs of panels. If the expandable panel hangs by itself, carefully pull out from the stack position about the distance of half a panel, then pivot it 90-degrees to position it in the opening. Use the handpulls provided to position the closure panels in place. CAUTION: Keep your hands and fingers from the panels edges. Hinged Panel A hinged panel closure simply swings into place after the last panel is extended. Engage the concealed footbolt located in the end of the last panel, and then close the hinged panel. A footbolt can also be used on the hinged panel to secure it in position. If the hinged panel is equipped with a latching mechanism, it can also be used as a pass door to go from one side to the other. Some configurations use a bi-fold (two panels) configuration hinged to the jamb. In this configuration, unfold the panels and position them flat to complete closure. CAUTION: Use the handpull and be careful to keep your hands and fingers from between the panels while extending them. Enclose An Enclose is the simplest closure method. All panels of the wall should be moved into position with their bottom seals set, if operable. The foot bolt provided in the trail edge of the last panel must be set also. To set the foot bolt, position it over the strike plate and push it down into the cavity. Caution: Do not attempt to move the panel while the foot bolt is in the down position. Next close each of the Enclose doors, hinged to the trail jamb, on both sides of the wall. The doors will magnetically latch in position to each side of the last panel. 4

6 Step 6: Stack the Partition Reverse the Closure Procedure Return the partition to the stack position in roughly a reverse of the set-up sequence. Disengage the closure panel first. To open an Enclose closure, open the doors on each side of the wall and fold them flat against the wall. Next raise the foot bolt, lift it by the top tab as far as it will go. Then slide the panel back slightly to disengage it from the next panel. For hinged panel closure, pull the panel open as you would with a door. With expandable panel closure, the bottom seals must be retracted before the expandable nose to prevent possible seal or mechanism damage. To do this, insert the operator handle into the bottom seal operator hole and turn it in the opposite direction used to extend the bottom seal until the seal is fully retracted. Then insert the handle in the expandable nose seal operator hole and turn it in the opposite direction used to extend the nose. The nose will retract and the panel can be disengaged from the next panel. Return the closure panel to the stack position. Raise the Bottom Seals Automatic 2-Inch Bottom Seals (Non-SureSet ) Automatic seals retract up into the panel as it is disengaged from the next panel. Grasp the back edge of the panel and pull. The panel will move back over the bottom seal and it will spring back up into the panel. If there are pass doors, be certain to raise the bottom seals in both the pass door and the pass door panel legs before raising the bottom seals in the adjacent panels on either side of the pass door panel. Cable Operated 2-inch Bottom Seals (Non-SureSet ) Cable operated seals are released in the same manner in which they are set. Grasp the bottom seal operator handle located either in the edge or on the face of the panel. Pull the handle to take up any slack in the cable, then pull firmly to raise the bottom seal until it latches. Return the handle to its original position. Do not let go of the handle and allow it to snap back into the panel. If there are pass doors, be certain to raise the bottom seals in both the pass door and the pass door panel legs before raising the bottom seals in the adjacent panels on either side of the pass door panel. Crank Operated 2-Inch Bottom Seals (Non-SureSet ) Crank operated seals are retracted up into the panel by inserting the removable operator handle into the operator hole located in either the edge or on the face of the panel. Rotate the handle clockwise to raise the bottom seal. Remove the handle after the seal is raised completely. If there are pass doors, be certain to raise the bottom seals in both the pass door and the pass door panel legs before raising the bottom seals in the adjacent panels on either side of the pass door panel. 5

7 SureSet Automatic 2-Inch or 4-Inch Bottom Seals The SureSet automatic bottom seal will retract up into both panels on its own after lifting the mechanism release leaver tab located in the trail edge of the panel. To do this, make certain you are not standing directly in line with the trail edge of the panel and you have neither leg within 12 inches of the trail edge of the panel. This will prevent being contacted by the automatic push bar when it releases out from the trail edge of the panel upon the release of the bottom seal mechanism. The automatic top seals retract down into the panel pair as they are disengaged from the next panel pair. Grasp the back edge of the panel and pull. The panel will move back under the top seal and it will spring back down into the panel. If there are pass doors, be certain to raise the bottom seals in both the pass door and the pass door panel legs before raising the bottom seals in the adjacent panels on either side of the pass door panel. SureSet Crank Operated 2-Inch or 4-Inch Bottom Seals The SureSet crank operated bottom seals are retracted up into the panels by inserting the removable operator handle into the operator hole located in the trail edge of the panel. Rotate the handle clockwise to raise the bottom seals of the pair. Remove the handle after the seal is raised completely. The automatic top seals retract down into the panel pair as they are disengaged from the next panel pair. Grasp the back edge of the panel and pull. The panel will move back under the top seal and it will spring back down into the panel. If there are pass doors, be certain to raise the bottom seals in both the pass door and the pass door panel legs before raising the bottom seals in the adjacent panels on either side of the pass door panel. Move Panels into Stack Position Return the panels to the stack position in the reverse sequence that they were brought out. Push each pair of panel s, watching both sides and ahead of the panels while they are in motion. Move the pair of panels at a walking pace: do not run, and do not push panels and let go. CAUTION: Be careful not to get your hands, clothing or anything else caught between the panel and another panel, jamb or fixed wall. If your partition has cable operated bottom seals, do not use the handle to tow the panels. 6

8 Step 7: Pass Doors Pass doors are provided in operable partitions to allow passage from one side of the partition to the other without having to reposition the panels. Most pass doors are provided with a pull handle and roller type latch mechanism. Simply pull or push the door to open it, and reverse the procedure to close it. Depending on the type of pass door, optional hardware can include a positive latch, a standard knob, a lever or a panic bar. If your partition has a pass door, it will have bottom seals in each leg as well as in the door itself. CAUTION: Before setting the seals in the pass door panel, position and set the seals in the panels on both sides of the pass door. There are three types of pass door bottom seal systems. Open the pass door to locate the bottom seal in one of the pass door legs. If there is a small lever at the top of this bottom seal, slide it to the left to lower the seal in the leg of the pass door panel. Repeat this procedure for the other leg of the pass door panel. If there is no lever, reach underneath the leg of the pass door panel and lift the seal until its latch releases. Slowly lower it to the floor. Repeat this procedure for the other leg of the pass door panel. The final type has crank down seals in the legs. There will be an operator access hole waist high in the edge of the leg, on each side, of the door opening. Insert the removable crank handle into the operator hole and crank the leg mechanism down until it stops. Repeat this procedure for the other leg of the pass door panel. Once the bottom seals in the door legs are set, set the door s seal either by pulling on the operator handle located in the edge of the door; by using a removable crank in the bottom of the hinged edge of the door; or by using the removable crank in the waist high operator of the hinged edge of the door. Some pass doors, especially those located next to panels without operable bottom seals, may require a foot bolt, on the panel to stabilize it. To set the footbolt, position it over the strike plate and push it down into the cavity. To raise the footbolt, lift it by the top tab as far as it will go. Do not attempt to move the panel while the footbolt is in the down position. 7

9 CLEANING AND MAINTENANCE Clean Panels Regular cleaning of the partition will help keep it looking new and alert you to damage. The following guidelines will help with most common cleaning situations. Heavily soiled surfaces may require professional services. As with other furniture, fabrics or carpets, any cleaning method should be tested in an inconspicuous area before general use on the panel surfaces. For vinyl, clean with a mild liquid household detergent. Rubbing alcohol will remove most ball-point pen marks. For carpet or fabric surfaces, use a stiff brush and vacuum cleaner, being careful not to fuzz the finish. Mild household detergent and water may help remove stubborn spots. Test any commercial cleaners or spot removers in an inconspicuous place. Work surfaces such as chalkboards or dry marker boards should be cleaned with a lint-free rag and clear water. For oily stains, use ammonia-based cleaners and thoroughly rinse with clear water. Clean and Lubricate Track Your local Modernfold Distributor has the proper tools and knowledge to perform track maintenance. Track should be cleaned and inspected yearly. Use a mop or rag dampened with mineral spirits to thoroughly clean the inside surfaces of the entire track layout. After cleaning, apply a light coat of petroleum jelly to the entire surface on which the carriers run. Do not use spray or silicone based lubricants. After the first and third years, check the track for proper leveling and readjust as necessary. This is particularly important on long spans, as truss deflections generally show up within the first three years. Check Top Seal Contact Surfaces Annually check all soffits and surfaces in contact with the top seals for wear or rough spots. Should the top seal no longer come in contact with the soffit, your local Modernfold Distributor can properly adjust the panels to bring the seal back into position. Because the adjustment of the carriers is critical to the proper operation of the panels, do not attempt to raise or lower them. Contact your local Modernfold Distributor. Inspect Panels The panels should be periodically checked for damage and repaired as necessary. Regularly inspect all bottom seals and operate the closures. If adjustments or repairs are required, contact your local Modernfold Distributor. After the first and third years of operation, panel vertical edges should be checked for plumb and, if necessary, adjusted for proper fit by your local Modernfold Distributor. 8

10 215 West New Road Greenfield, IN Toll Free: A DORMA Group Company Form No Manufacturer reserves the right to change design or specifications at any time without notice. Please contact your local Modernfold distributor for further assistance, or visit our website at 9

Moduflex High Performance Operable Walls

Moduflex High Performance Operable Walls Operation and Maintenance Manual Moduflex High Performance Operable Walls This manual provides important safety, operation and maintenance information for your Panelfold Moduflex operable wall(s). These

More information

Basic Assembly For Conventional Series 9000 Structural Panels

Basic Assembly For Conventional Series 9000 Structural Panels Steelcase, Inc. Grand Rapids, MI 49501 U.S.A. 1-888-783-3522 Basic Assembly For Conventional Series 9000 Structural Panels NOTE: Assembly directions for curved panels are the same as standard panels. Tools

More information

INSTALLATION GUIDE. TRANZFORM Sound TRANZFORM Space

INSTALLATION GUIDE. TRANZFORM Sound TRANZFORM Space INSTALLATION GUIDE TRANZFORM Sound TRANZFORM Space Cornell Iron Works, Inc. 100 Elmwood Ave. Crestwood Industrial Park Mountain Top, PA 18707 Phone: 800.233.8366 or 570.474.6773 Fax: 800.526.0841 INSTALLATION

More information

INSTALLATION AND CARE INSTRUCTIONS

INSTALLATION AND CARE INSTRUCTIONS INSTALLATION AND CARE INSTRUCTIONS Skylight Manually Operated Honeycomb Shades 20 C8-10-1806 2/15 1 INTRODUCTION Thank you for purchasing our product. Your new shade has been custom built for you from

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS BUILDERS CHOICE FRAMED Shower Height Swing Door Model: L533 Rev. 09.03.13 MAINTENANCE: Two primary materials are used to manufacture your new Aquatic enclosure; tempered glass

More information

INSTALLATION GUIDE 2009-CURRENT HUMMER H3T PRODUCT CODE:

INSTALLATION GUIDE 2009-CURRENT HUMMER H3T PRODUCT CODE: INSTALLATION GUIDE 2009-CURRENT HUMMER H3T PRODUCT CODE: 268 June 22, 2010 TOOLS NEEDED COMPONENTS INCLUDED P2 Tip 3/8" Drill Rubber Gasket(s) x 2 Bracket(s) x 2 1/2" Drill Bit Bulkhead Flange #2 Phillips

More information

Phone # La Jolla Doors. Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels

Phone # La Jolla Doors. Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels Phone # 800-440-8785 www.lajolladoors.com La Jolla Doors Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels Thank you for choosing La Jolla Doors In this manual you will

More information

PRODUCT INFORMATION MANUAL SECTION: 9F-1 DUETTE ULTRAGLIDE LIFTING SYSTEM DUETTE SIGNATURE ULTRAGLIDE LIFTING SYSTEM

PRODUCT INFORMATION MANUAL SECTION: 9F-1 DUETTE ULTRAGLIDE LIFTING SYSTEM DUETTE SIGNATURE ULTRAGLIDE LIFTING SYSTEM DUETTE SIGNATURE ULTRAGLIDE LIFTING SYSTEM Product View Installation Brackets UltraGlide Standard Wand Top-Down/Bottom-Up Duolite REPLACES ISSUE DATE: APPROVED BY: D.ALTIPARMAKOVA PAGE 3 Thank you for

More information

Half Door Installation Instructions

Half Door Installation Instructions Half Door Installation Instructions For: CJ5 (1955-1975), CJ6 (All), M38-A1 (1955-1971) Part Number: 53025 WARNING This product is designed primarily to enhance the appearance of the vehicle and to shield

More information

WHISPER Cellular EasyRise Shades. Installation Operation Care

WHISPER Cellular EasyRise Shades. Installation Operation Care WHISPER Cellular EasyRise Shades Installation Operation Care 05/2013 CONTENTS Getting Started: Product View... 1 Tools and Fasteners Needed... 2 Installation: Installation Overview... 3 Mounting Types

More information

Installation Operation Care

Installation Operation Care Installation Operation Care Applause Honeycomb Shades LiteRise Operating System with TrimKit Contents GETTING STARTED Product View... 1 Tools and Fasteners Needed... 2 INSTALLATION Installation Overview...

More information

Installation And Care Instructions. Vertical Honeycomb Shades

Installation And Care Instructions. Vertical Honeycomb Shades Installation And Care Instructions Vertical Honeycomb Shades Rev 5/2013 Table Of Contents Getting Started... 3 Parts Overview... 4 Materials Required... 5 Tools Required... 6 Outside Mount Installation...

More information

Door Installation. Bulletin Install Read and understand these instructions before proceeding! It saves frustration!

Door Installation. Bulletin Install Read and understand these instructions before proceeding! It saves frustration! Door Installation Door Series: 3300 Bulletin 1 Preparation Preliminary Examination Inspect the packaging. If the package was damaged when it arrived, contact the shipping carrier first, then notify Woodfold.

More information

Cellular SlumberShade

Cellular SlumberShade Cellular SlumberShade with energy saving blackout sidetracks Installation Instructions 152110 1/6/2011 BASICS A few simple tools are required: - Measuring tape - Power drill, drill bits - Hex head and/or

More information

INSTALLATION AND CARE INSTRUCTIONS

INSTALLATION AND CARE INSTRUCTIONS INSTALLATION AND CARE INSTRUCTIONS Vertical Applications Honeycomb Shades CONTENTS Introduction...2 Before You Begin...3 Vertical Application Parts Overview...4 Materials Required...5 Tools Required...6

More information

DUETTE LITERISE SHADES INSTALLATION OPERATION CARE

DUETTE LITERISE SHADES INSTALLATION OPERATION CARE DUETTE LITERISE SHADES INSTALLATION OPERATION CARE PRODUCT VIEW Installation Brackets Headrail with Fabric-Covered Valance End Cap Middle Rail Bottom Up Shade Bottom Rail Handle Duolite Not Shown: Top

More information

Installation Operation Care

Installation Operation Care Installation Operation Care Applause Honeycomb Shades LiteRise Operating System Contents GETTING STARTED Product View...1 Tools and Fasteners Needed...2 INSTALLATION Installation Overview...3 Mount the

More information

1200 SERIES 2 PANEL DOOR rev.1 DETAILED INSTALLATION INTRUCTIONS

1200 SERIES 2 PANEL DOOR rev.1 DETAILED INSTALLATION INTRUCTIONS 1200 SERIES 2 PANEL DOOR 10.2013 rev.1 DETAILED INSTALLATION INTRUCTIONS GENERAL: Door elevations shown in these instructions are as viewed from the outside. X denotes the active or moving panel(s). O

More information

Vertical Honeycomb Shades

Vertical Honeycomb Shades Step by Step Installation Instructions Vertical Honeycomb Shades Customer Service 800.248.8888 or visit us online at smithandnoble.com Thank you for purchasing from Smith+Noble. Your new shades have been

More information

HR175 Sash Replacement Kit Installation Instructions

HR175 Sash Replacement Kit Installation Instructions HR175 Sash Replacement Kit Installation Instructions IMPORTANT: Please read before you begin. Weather Shield HR175 Sash Replacement Kits Important: Thoroughly read and follow these instructions, failure

More information

INSTALLATION AND CARE INSTRUCTIONS

INSTALLATION AND CARE INSTRUCTIONS INSTALLATION AND CARE INSTRUCTIONS Vertical Applications Honeycomb Shades 52 C8-10-3401 Rev 2/14 CONTENTS Introduction...2 Before You Begin...3 Vertical Application Parts Overview...4 Materials Required...5

More information

Quick Fit Installation Guide Retractable Screen - Double Door

Quick Fit Installation Guide Retractable Screen - Double Door Quick Fit Installation Guide Retractable Screen - Double Door 1 REMOVE KIT PARTS FROM SHIPPING TUBE 2 Slide bolts 2 Rail receiver Clips 15 Mounting screws 1 Housing end cap screw 2 Handles 1 Housing end

More information

Installation Operation Care

Installation Operation Care Installation Operation Care Palm Beach Polysatin Shutters CONTENTS Getting Started Installation Overview...1 Unpacking...1 Tools and Materials Needed...1 Fasteners...2 Frame Assembly Assemble the Frame

More information

MUTO COMFORT DORMOTION XL 150/80 L 80

MUTO COMFORT DORMOTION XL 150/80 L 80 MUTO COMFORT DORMOTION XL 150/80 L 80 Installation instructions - Wall mount with DORMOTION ( ) TABLE OF CONTENTS Closer overall Overview Intended use Wall requirements and fittings Safety instructions

More information

UNIT No FRAMELESS PIVOT SHOWER DOOR

UNIT No FRAMELESS PIVOT SHOWER DOOR INSTALLATION INSTRUCTIONS UNIT No. 3600 FRAMELESS PIVOT SHOWER DOOR NEED INSTALLATION HELP? Call 1-800-45-BASCO (452-2726) Monday - Friday 8:00 A.M. - 4:30 P.M. Eastern Time QCI0020 Rev. 3 Page 1 of 8

More information

1/4 FRAMELESS DOOR WITH INLINE PANEL 1413A-1713A-1813A

1/4 FRAMELESS DOOR WITH INLINE PANEL 1413A-1713A-1813A 1/4 FRAMELESS DOOR WITH INLINE PANEL 1413A-1713A-1813A F AB GLASS AND MIRROR www.fabglassandmirror.com Call: +1 888-474-2221 Fax: (614)-334-4919 Office Timing: 8:30-18:00 EST info@fabglassandmirror.com

More information

HD-CXENVL-FDR Envelope Feeder Assembly and Operations Guide

HD-CXENVL-FDR Envelope Feeder Assembly and Operations Guide HD-CXENVL-FDR Envelope Feeder Assembly and Operations Guide Rev. 12-12-16 1 Table of Contents DESCRIPTION OF FUNCTION... 3 Time-out (out of paper) Feature... 3 PREPARING THE HD-CX1600/1700 (C9x1) PRINTER...

More information

INSTALLATION INSTRUCTIONS FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE QCI5233

INSTALLATION INSTRUCTIONS FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE QCI5233 INSTALLATION INSTRUCTIONS FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE QCI5233 QCI5233 Rev 0 Page 1 Certified 06/20/2016 INSTALLATION NOTES: Unpack your unit carefully and inspect for freight damage. Lay

More information

Fig. 2 DORMA-Glas Stand/Issue 02/03 Seite/Page 1/7

Fig. 2 DORMA-Glas Stand/Issue 02/03 Seite/Page 1/7 FSW Installation instructions Track rail 75 x 72 mm 1. Ceiling substructure and installation of the track rail (Fig. 1): The track rail must be bolted over its entire length (including the stacking track

More information

MUTO COMFORT XL 150 L 80

MUTO COMFORT XL 150 L 80 MUTO COMFORT XL 150 L 80 Installation instructions - Ceiling mount [less DORMOTION] ( door) TABLE OF CONTENTS Overview Intended use Ceiling requirements and fittings Requirements for glass panel Safety

More information

Please read these instructions before use and keep for future reference

Please read these instructions before use and keep for future reference Wardrobe Assembly Guide Allen Key Provided (if required) Philips Screwdriver Required Hammer Required Please read these instructions before use and keep for future reference Caution! Two Person Assembly

More information

Product must be installed as shown using the screws and brackets provided. Use of incorrect hardware could result in damage to the product.

Product must be installed as shown using the screws and brackets provided. Use of incorrect hardware could result in damage to the product. General Notes These installation instructions are intended to be comprehensive for a typical Keyeira/Presto configuration. Your configuration may differ. If you have questions contact Geiger Customer Service

More information

How to operate (folding)

How to operate (folding) How to operate (folding) LEFT HAND STACKING OUTWARD OPENING How to operate (folding) RIGHT HAND STACKING OUTWARD OPENING LOCK BOTH LEVER HANDLE AND FLAT HANDLE UTILISING THE D-HANDLE LOCATED ABOVE THE

More information

SIDE FOLDING INSTALLATION GUIDE SLIM LINE 4 INCH STANDARD 7 INCH WIDE BODY 11 INCH

SIDE FOLDING INSTALLATION GUIDE SLIM LINE 4 INCH STANDARD 7 INCH WIDE BODY 11 INCH SIDE FOLDING INSTALLATION GUIDE SLIM LINE 4 INCH STANDARD 7 INCH WIDE BODY 11 INCH ----------------------------- INSTALLATION STEPS ------------------------- TABLE OF CONTENTS WARNINGS AND SAFETY INFORMATION

More information

tile redi redi DOOR Redi Redi Swing Slide g TM TM...Opening Doors to Stunning Showers! TM TM SERIES: CONFIGURATION: MOUNTING PACKAGE:

tile redi redi DOOR Redi Redi Swing Slide g TM TM...Opening Doors to Stunning Showers! TM TM SERIES: CONFIGURATION: MOUNTING PACKAGE: redi DOOR INSTALLATION INSTRUCTIONS tile redi Redi Redi Swing Slide g TM TM...Opening Doors to Stunning Showers! TM TM SERIES: CONFIGURATION: MOUNTING PACKAGE: 1100 Door-Door Framed sliding doors RDQCI5023

More information

TABLE OF CONTENTS CHAPTER 1: IMPORTANT SAFETY INSTRUCTIONS

TABLE OF CONTENTS CHAPTER 1: IMPORTANT SAFETY INSTRUCTIONS TABLE OF CONTENTS CHAPTER 1: IMPORTANT SAFETY INSTRUCTIONS PAGES 1.1 Read and Save These Instructions... 02 1.2 Proper Usage... 02 1.3 Setting up the Krankcycle... 02 CHAPTER 2: KRANKCYCLE SPECIFICATIONS,

More information

Oxford Stalls Installation Instructions

Oxford Stalls Installation Instructions Oxford Stalls Installation Instructions RAMM Horse Fencing and Stalls 13150 Airport Hwy. Swanton, OH 43558-9615 1-800-434-8456 Rev. 8/15/17 Before You Start Typical stall sizes are 10 x 10, 12 x 12 or

More information

6400, 8400 and 9400 Series Sliding Patio Door

6400, 8400 and 9400 Series Sliding Patio Door Contemporary 3 Panel Classic 5 Panel French Panel 6400, 8400 and 9400 Series Sliding Patio Door (O) Fixed Panel Left (X) Operating / Mullion Panel Right (X) Operating / Lock Panel Left (O) Fixed Panel

More information

SIDE FOLDING POST ADJUSTMENTS

SIDE FOLDING POST ADJUSTMENTS SIDE FOLDING POST ADJUSTMENTS TABLE OF CONTENTS WARNINGS AND SAFETY INFORMATION 3 TOOLS REQUIRED 4 GENERAL NOTES 5 POST IDENTIFICATION 6 POST TO CURTAIN CONNECTIONS 8 P01/P03 LOCK PLATE HEIGHT ADJUSTMENT

More information

Installation Manual Flat Track Series

Installation Manual Flat Track Series Manual Flat Track Series Contents Safety...1 Parts...2 Hardware.......................................... 2 Tools Required..................................... 4.............................................

More information

Installing Your Electronic Deadbolt

Installing Your Electronic Deadbolt Ultra Security Plus Electronic Deadbolt Installation Instructions http://www.hberger.com/video-gallery/electronic-deadbolt New Installation Lock Location Preparation (Skip this section if you door has

More information

tile redi redi DOOR Redi Redi Swing Slide g TM TM...Opening Doors to Stunning Showers! TM TM SERIES: CONFIGURATION: MOUNTING PACKAGE:

tile redi redi DOOR Redi Redi Swing Slide g TM TM...Opening Doors to Stunning Showers! TM TM SERIES: CONFIGURATION: MOUNTING PACKAGE: redi DOOR INSTALLATION INSTRUCTIONS tile redi Redi Redi Swing Slide g TM TM...Opening Doors to Stunning Showers! TM TM SERIES: CONFIGURATION: MOUNTING PACKAGE: 3000 Door-Door Header, sliding doors RDQCI5301

More information

Installation Operation Care

Installation Operation Care Installation Operation Care Provenance Woven Wood Shades Standard Cordlock CONTENTS Getting Started: Product View... 1 Tools and Fasteners Needed... 2 Installation: Installation Overview... 3 Mount the

More information

Contemporary 3 Panel Classic 5 Panel French Panel

Contemporary 3 Panel Classic 5 Panel French Panel Contemporary 3 Panel Classic 5 Panel French Panel (X) Operating / Lock Panel Left (O) Fixed Panel Right Note : Glazing Beads For All Panel Face To The Exterior 2 Panel XO Left Is Shown Above Opposite =

More information

675 Quick N Stall Neo Angle Framed Hinge Shower Enclosure

675 Quick N Stall Neo Angle Framed Hinge Shower Enclosure INSTALLATION INSTRUCTIONS 675 Quick N Stall Neo Angle Framed Hinge Shower Enclosure Call Technical Dept @ 1-800-452-2726 QCI1003 Page 1 of 9 Certified 10/01/09 INSTALLATION NOTES: Unpack your unit carefully

More information

Panoramic Door. Block Frame Installation Manual Aluminum top and bottom track with either aluminum or vinyl panels

Panoramic Door. Block Frame Installation Manual Aluminum top and bottom track with either aluminum or vinyl panels 2515 Industry St. Oceanside, CA 92058 760-722-1250 www.panoramicdoors.com Panoramic Door Block Frame Installation Manual Aluminum top and bottom track with either aluminum or vinyl panels Signature Aluminum

More information

Frameless Inline Door With Return QCI5263

Frameless Inline Door With Return QCI5263 INSTALLATION INSTRUCTIONS Frameless Inline Door With Return QCI5263 WALL MOUNT HINGES FRAMELESS DOOR / PANEL / RETURN PANEL QCI5263 REV. 0 Page 1 Certified 06/17/2016 Parts List with wall mount hinges

More information

INSTALLATION INSTRUCTIONS FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE QCI5232

INSTALLATION INSTRUCTIONS FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE QCI5232 INSTALLATION INSTRUCTIONS FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE QCI5232 QCI5232 Rev 0 Page 1 Certified 06/20/2016 INSTALLATION NOTES: Unpack your unit carefully and inspect for freight damage. Lay

More information

Please read and understand all instructions before beginning. These instructions cover impact and non-impact aluminum French Door 650/750.

Please read and understand all instructions before beginning. These instructions cover impact and non-impact aluminum French Door 650/750. The performance and proper operation of a door is only as good as the installation. By following these instructions, the probability of a good installation greatly increases. Please read and understand

More information

Atrium Patio Door Field Service Manual

Atrium Patio Door Field Service Manual Atrium Patio Door Field Service Manual December 2005 Table of contents Service Agreement Pg 2 Release Agreement Pg 5 Inspection form Pg 6 Warranty Pg 8 Replacing swing panel Pg 12 Replacing sliding panel

More information

Continuous Hinge Frameless Single Swing Shower Enclosure QCI-5214

Continuous Hinge Frameless Single Swing Shower Enclosure QCI-5214 INSTALLATION INSTRUCTIONS Continuous Hinge Frameless Single Swing Shower Enclosure QCI-5214 QCI5214 Rev. 1 Page 1 of 8 Certified 09/19/18 MAINTENANCE: Two primary materials are used to manufacture your

More information

Panoramic Door Block Frame Installation Manual

Panoramic Door Block Frame Installation Manual Units 5 & 6 Park House Lane Sheffield S9 1XA 01142 439593 Panoramic Door Block Frame Installation Manual Panoramic Door Block Frame Door Installation Guide 10-10-17 1 of 1 Thank you for choosing Panoramic

More information

Quick Fit Installation Guide Retractable Screen - Single Door

Quick Fit Installation Guide Retractable Screen - Single Door Quick Fit Installation Guide Retractable Screen - Single Door 1 REMOVE KIT PARTS FROM SHIPPING TUBE 15 Mounting screws 1 Housing end cap screw 2 Handles 1 Housing end cap 1 Bushing 1 Pull bar end cap 2

More information

N. 15th Street, Middlesboro, KY FLIP TARP DUMP BODY INSTALLATION INSTRUCTIONS

N. 15th Street, Middlesboro, KY FLIP TARP DUMP BODY INSTALLATION INSTRUCTIONS 1-800-248-7717 1002 N. 15th Street, Middlesboro, KY 40965 FLIP TARP DUMP BODY INSTALLATION INSTRUCTIONS Congratulations on your purchase of a Mountain Flip Tarp Dump Body tarping system. With tarping systems

More information

SYSTEM 42 SCREEN CASSETTE WITH 30mm SIDE RAIL

SYSTEM 42 SCREEN CASSETTE WITH 30mm SIDE RAIL LEGENDS VERTICAL WINDOW RETRACTABLE SCREEN SYSTEM 42 SCREEN CASSETTE WITH 30mm SIDE RAIL I N S T A L L A T I O N I N S T R U C T I O N NOTE: Screen components must be installed on a flat surface to ensure

More information

Maintenance Guide 11/12

Maintenance Guide 11/12 Product Maintenance Guide 11/12 C abinetry Care, Cleaning & Adjustment Guide After installation care After your cabinets have been installed, wipe down exteriors with a clean damp cloth. Work on a small

More information

STRINGING MACHINE OWNER'S MANUAL. Copyright 1998 GAMMA Sports - All Rights Reserved

STRINGING MACHINE OWNER'S MANUAL. Copyright 1998 GAMMA Sports - All Rights Reserved 6002 STRINGING MACHINE OWNER'S MANUAL Issue 3 - June 20, 1998 Copyright 1998 GAMMA Sports - All Rights Reserved 6002 OWNER'S MANUAL TABLE OF CONTENTS PAGE 1... WARRANTY PAGE 2... FEATURES PAGE 3... ASSEMBLY

More information

Unit No. 4400, 4500 Classic Frameless Sliding Tub/Shower Enclosure INSTALLATION INSTRUCTIONS

Unit No. 4400, 4500 Classic Frameless Sliding Tub/Shower Enclosure INSTALLATION INSTRUCTIONS Unit No. 4400, 4500 Classic Frameless Sliding Tub/Shower Enclosure INSTALLATION INSTRUCTIONS MAINTENANCE: Two primary materials are used to manufacture your new Basco enclosure: tempered glass and anodized

More information

HEIGHT ADJUSTABLE WORKBENCH

HEIGHT ADJUSTABLE WORKBENCH HEIGHT ADJUSTABLE WORKBENCH Model 91 ASSEMBLY and Operating Instructions Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result in

More information

EURO (3876) Euro-C2 Installation Instructions Euro-Wall Systems, LLC

EURO (3876)   Euro-C2 Installation Instructions Euro-Wall Systems, LLC 888.989.EURO (3876) www.euro-wall.com Euro-C2 Installation Instructions Installation Instructions Euro-C2 step A.1) Assemble Bottom corner Pre-caution: it is recommended to use screw wax to prevent screw

More information

Pre-Hanging Information

Pre-Hanging Information Pre-Hanging Information Difference between Door Slab and Pre-hung Door Door Slab Only Door Slab Only No handle preparation. No deadbolt preparation. No frame or hinges included. Pre-hung door Door unit

More information

Half Door Installation Instructions

Half Door Installation Instructions Half Door Installation Instructions For: CJ7, CJ8/Scrambler and Wrangler/YJ Part Number: 53028 Note: Wrangler/YJ Use of this product may not allow use of factory side mirrors. Note: Wrangler/YJ Use of

More information

Product Care & Cleaning Guide

Product Care & Cleaning Guide Product Care & Cleaning Guide /5 CABINETRY CARE, CLEANING & ADJUSTMENT GUIDE AFTER INSTALLATION CARE After your cabinets have been installed, wipe down exteriors with a clean damp cloth. Work on a small

More information

Sliding Glass Door Assembly and Installation Guide

Sliding Glass Door Assembly and Installation Guide Sliding Glass Door Assembly and Installation Guide Index Door System Components and Hardware The following components are needed to complete the installation of your Sliding Patio Door unit. Check all

More information

Magnaline Systems Block Frame Installation Manual

Magnaline Systems Block Frame Installation Manual 2515 Industry St. Oceanside, CA 92058 Magnaline Systems Block Frame Installation Manual Aluminum top and bottom track with either aluminum or vinyl panels Thank you for choosing Magnaline Systems! Congratulations!

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS A CSW Industrials Company FGLP with Cast-In Frames FGLP-A, FGLP-C, FGLP-D IMPORTANT The following instructions are very important. Read them carefully, and be sure you understand

More information

Series----SP3600A SHOWER DOOR

Series----SP3600A SHOWER DOOR Series----SP3600A SHOWER DOOR INSTALLATION INSTRUCTIONS Please read these instructions carefully to familiarize yourself with the required tools, materials, and installation sequences. The Exploded Diagram

More information

XL JOINERY LTD LA PORTE VISTA MODULAR 3 ASSEMBLY INSTRUCTIONS

XL JOINERY LTD LA PORTE VISTA MODULAR 3 ASSEMBLY INSTRUCTIONS XL JOINERY LTD LA PORTE VISTA MODULAR 3 2090mm High x 4687mm Wide ASSEMBLY INSTRUCTIONS READ AND UNDERSTAND THESE INSTRUCTIONS FULLY PRIOR TO STARTING INSTALLATION. IT IS STRONGLY RECOMMENDED THAT A COMPETENT

More information

Retractable Screen Installation Instructions For Vinyl and Aluminum Clad and Wood In-Swing Hinged Doors (See separate instructions for sliding doors)

Retractable Screen Installation Instructions For Vinyl and Aluminum Clad and Wood In-Swing Hinged Doors (See separate instructions for sliding doors) Retractable Screen Installation Instructions For Vinyl and Aluminum Clad and Wood In-Swing Hinged Doors (See separate instructions for sliding doors) IMPORTANT: Please read before you begin. Table of Contents

More information

Unit No. 6150, 7150 Deluxe Framed Sliding Tub/Shower Enclosure

Unit No. 6150, 7150 Deluxe Framed Sliding Tub/Shower Enclosure INSTALLATION INSTRUCTIONS Unit No. 6150, 7150 Deluxe Framed Sliding Tub/Shower Enclosure QCI0023 Rev. 1 Page 1 of 8 Certified 8/20/10 MAINTENANCE: Two primary materials are used to manufacture your new

More information

Installation Instructions. Oakmont Folding Doors

Installation Instructions. Oakmont Folding Doors Before You Start For quick and easy installation of your Oakmont folding door, read these instructions thoroughly. A few minutes of prior planning will make the job easier and ensure years of trouble-free

More information

VYTEX PREMIUM SLIDING GLASS DOOR. Table of Contents. Precautions and Safety 2. Tools Required...3. Inspect and Prepare Door...4

VYTEX PREMIUM SLIDING GLASS DOOR. Table of Contents. Precautions and Safety 2. Tools Required...3. Inspect and Prepare Door...4 VYTEX PREMIUM SLIDING GLASS DOOR Table of Contents Precautions and Safety 2 Tools Required...3 Inspect and Prepare Door...4 Hardware and Parts Check List....4 Master Frame Assembly 5 Master Frame Installation..7

More information

southpaw enterprises, inc.

southpaw enterprises, inc. southpaw enterprises, inc. Instruction Sheet C-STAND 7100 Store these instructions in a safe place or with the enclosed maintenance checklist Take time to familiarize yourself with the use and maintenance

More information

Specifications: Hole Sizes: Selector Pin Hole: 3/8 (0.375 ) Trigger Pin Hole: 5/32 (0.156 ) Hammer Pin Holes: 5/32 (0.156 )

Specifications: Hole Sizes: Selector Pin Hole: 3/8 (0.375 ) Trigger Pin Hole: 5/32 (0.156 ) Hammer Pin Holes: 5/32 (0.156 ) 80% Arms AR-15 Jig manual Thank you for purchasing our AR- 15 jig. This precision self- aligning jig will allow you to finish your 80% Arms and other 80% lowers using only a drill press and a few common

More information

TABLE OF CONTENTS CHAPTER 1: IMPORTANT SAFETY INSTRUCTIONS. 1.1 Read and Save These Instructions Proper Usage... 02

TABLE OF CONTENTS CHAPTER 1: IMPORTANT SAFETY INSTRUCTIONS. 1.1 Read and Save These Instructions Proper Usage... 02 Krankcycle_091021.indd 1 TABLE OF CONTENTS CHAPTER 1: IMPORTANT SAFETY INSTRUCTIONS PAGES 1.1 Read and Save These Instructions... 02 1.2 Proper Usage... 02 1.3 Setting up the KRANKcycle... 02 CHAPTER 2:

More information

LEVOLOR. Sheer Shadings. Persianas traslúcidas Stores diaphanes INSTALLATION OPERATION CARE

LEVOLOR. Sheer Shadings. Persianas traslúcidas Stores diaphanes INSTALLATION OPERATION CARE LEVOLOR Sheer Shadings Persianas traslúcidas Stores diaphanes INSTALLATION OPERATION CARE INSTALACIÓN FUNCIONAMIENTO CUIDADO INSTALLATION FONCTIONNEMENT ENTRETIEN Sistema operativo sin cordón Système sans

More information

Double Swing Door With Header QCI5114

Double Swing Door With Header QCI5114 Double Swing Door With Header QCI5114 QCI5114 REV. 0 Page 1 of 9 Certified 06/22/2016 MAINTENANCE: Two primary materials are used to manufacture your new shower enclosure: tempered glass and anodized aluminum.

More information

Introduction to Carpentry Power Tools

Introduction to Carpentry Power Tools Youth Explore Trades Skills Introduction to Carpentry Power Tools Description s use power tools every day, and the ability to use these tools correctly and safely is paramount. In this Activity Plan, students

More information

QCI0029 REV. 1 Page 1 of 11 Certified 07/06/05

QCI0029 REV. 1 Page 1 of 11 Certified 07/06/05 QCI0029 REV. 1 Page 1 of 11 Certified 07/06/05 MAINTENANCE: Two primary materials are used to manufacture your new Basco enclosure: tempered glass and anodized aluminum. To assure a long lasting finish

More information

Vanity Cabinets and Mirrors Installation and User Guide

Vanity Cabinets and Mirrors Installation and User Guide Vanity Cabinets and Mirrors Installation and User Guide MODEL NUMBERS 2451, 2452, 2454, 2455, 2457, 2459, 2453, 2456, 2458, 2460, 2470, 2473 Important :- Please quote the above model number(s) when ordering

More information

AutoSeal FD 2006IL / FE 2006IL

AutoSeal FD 2006IL / FE 2006IL AutoSeal FD 2006IL / FE 2006IL FI / FJ Series 06/2018 OPERATOR MANUAL First Edition TABLE OF CONTENTS DESCRIPTION 1 SPECIFICATIONS 1 UNPACKING 1 SETUP 2 Sealer Alignment Base Setup 2 Sealer Setup 2-4

More information

Hardware and Components:

Hardware and Components: Hardware and Components: (A) 4X 5/16 x 1 Carriage Bolt (B) 2X 5/16 x 2-1/4 Carriage Bolt (C) 2X 5/16 x 3-1/4 Hex Bolt (D) 2X 5/16 x 3/4 Hex Bolt (E) 2X 5/16 x 1-1/4 Hex Bolt (F) 5/16 x 2-1/4 Hex Bolt (G)

More information

Unit No. 1400, 1700, 1800 Infinity Continuous Hinge Frameless Swing Door Shower Enclosure

Unit No. 1400, 1700, 1800 Infinity Continuous Hinge Frameless Swing Door Shower Enclosure INSTALLATION INSTRUCTIONS Unit No. 1400, 1700, 1800 Infinity Continuous Hinge Frameless Swing Door Shower Enclosure QCI0028 Rev. 2 Page 1 of 10 Certified 06/05/09 MAINTENANCE: Two primary materials are

More information

Installation Materials Required: Tools Required: 6" self-adhesive flashing. Shims. 3-foot level 6-foot level Tape measure 1/8" drill bit

Installation Materials Required: Tools Required: 6 self-adhesive flashing. Shims. 3-foot level 6-foot level Tape measure 1/8 drill bit installation instructions for CUSTOM WOOD & FIBERGLASS EXTERIOR FOLDING DOOR SYSTEMs (JII101) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for

More information

INSTALLATION INSTRUCTIONS. UNIT No. 160/760 THIN-LINE SHOWER ENCLOSURE

INSTALLATION INSTRUCTIONS. UNIT No. 160/760 THIN-LINE SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS UNIT No. 160/760 THIN-LINE SHOWER ENCLOSURE QCI0011 Rev. 0 Page 1of 10 Certified 10/18/2006 MAINTENANCE: Two primary materials are used to manufacture your new Basco enclosure;

More information

Installation Operation Care

Installation Operation Care Installation Operation Care NewStyle Hybrid Shutters 9930011143F 4/18 CONTENTS Getting Started Installation Overview... 1 Unpacking... 1 Tools and Materials Needed... 1 Fasteners... 2 Frame Assembly Assemble

More information

GARAGE DOOR WITH TORSION SPRING

GARAGE DOOR WITH TORSION SPRING GARAGE DOOR WITH TORSION SPRING DIMENSIONS 9 WIDTH X 7 HEIGHT (2.74m x 2.13m) IMPORTANT SAFETY INSTRUCTIONS WARNING: Read all instructions and warnings before use. Failure to follow all instructions may

More information

Half Door Installation Instructions

Half Door Installation Instructions Half Door Installation Instructions For: CJ5 (1955-1975), CJ6 (All), M38-A1 (1955-1971) Part Number: 53025 Congratulations on your purchasing decision. Bestop designed these Doors to give you years of

More information

INFINITE RANGE - CENTRE FOLDING DOOR

INFINITE RANGE - CENTRE FOLDING DOOR INFINITE RANGE - CENTRE FOLDING DOOR CENTRE FOLDING DOOR ONLY ( RECESS) Please read these instructions before installing, as incorrect fitting will invalidate the guarantee-carry out each stage before

More information

60 DIRECT-TO-STUD SHOWER WALL SET

60 DIRECT-TO-STUD SHOWER WALL SET 60 DIRECT-TO-STUD SHOWER WALL SET 60 X 30 MODEL # DKW6008-XX 60 X 32 MODEL # DKW6028-XX 60 X 36 MODEL # DKW6068-XX Unit consists of Model DB608-XX Backwall, and requires one of the following Side Panel

More information

LEGENDS RETRACTABLE DOOR SCREENS

LEGENDS RETRACTABLE DOOR SCREENS LEGENDS RETRACTABLE DOOR SCREENS MAGNETIC LATCHING DESIGN SYSTEM 42 I N S T A L L A T I O N I N S T R U C T I O N S 1 MOUNTING OPTIONS Recess : Mount the Screen Cassette using Recess Mounting Clips Recess

More information

FRAMED PANEL / DOOR / PANEL CONTINUOUS HINGE SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

FRAMED PANEL / DOOR / PANEL CONTINUOUS HINGE SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS FRAMED / DOOR / CONTINUOUS HINGE SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS QCI5229 Rev 0 6 INSTALLATION NOTES: Unpack your unit carefully and inspect for freight damage. Lay out and identify all parts

More information

VALENCIA RONDO DOOR WITH RETURN

VALENCIA RONDO DOOR WITH RETURN VALENCIA RONDO DOOR WITH RETURN INSTALLATION GUIDE SEALANT REQUIRED TO COMPLETE THIS INSTALLATION: ( not supplied) Sika Silaflex NG To seal the WHITE shower door and returns to the shower tray. Usage:

More information

Riverside. Windward Bay EntertaInment Wall System Assembly Instructions. Made In Viet Nam. Right Pier. Bridge & Back Panel.

Riverside. Windward Bay EntertaInment Wall System Assembly Instructions. Made In Viet Nam. Right Pier. Bridge & Back Panel. EntertaInment Wall System Page 1 of 12 Product No. 42840 42848 42849 42843 Product Description Console Left Pier Right Pier Bridge & Back Panel Right Pier Bridge & Back Panel Left Pier 63" Inch Ent. Console

More information

Corded Honeycomb Shades

Corded Honeycomb Shades Corded Honeycomb Shades Remove shade from package. Save packaging until shade is installed and working to your satisfaction. Level Tape Measure Pencil Power drill Screwdriver s for different mounting surface:

More information

New Roman Shades WARNING. Installation Operation Care. Retractable Cord Lifting System

New Roman Shades WARNING. Installation Operation Care. Retractable Cord Lifting System CHILD SAFETY Warning WARNING For more safety information call 1-888-501-8364 in the U.S. or 1-866-662-0666 in Canada. Young children can wrap cords around their necks and STRANGLE. Always keep cords out

More information

VALENCIA CORNER DOOR WITH RETURN

VALENCIA CORNER DOOR WITH RETURN VALENCIA CORNER DOOR WITH RETURN INSTALLATION GUIDE SEALANT REQUIRED TO COMPLETE THIS INSTALLATION: ( not supplied) Sika Silaflex NG To seal the WHITE shower door and returns to the shower tray. Usage:

More information

MOVEABLE GLASS WALL TECHNICAL DATA

MOVEABLE GLASS WALL TECHNICAL DATA Ideal for applications requiring space division, visibility, and security. Used in banks, office lobbies, conference areas, interior storefronts, and arena skyboxes. Clean look of secure, yet easily moveable

More information

FLIP TARP SINGLE & DOUBLE UNDERBODY TRAILERS

FLIP TARP SINGLE & DOUBLE UNDERBODY TRAILERS 1-800-248-7717 1002 N. 15th Street, Middlesboro, KY 40965 FLIP TARP SINGLE & DOUBLE UNDERBODY TRAILERS INSTALLATION INSTRUCTIONS Congratulations on your purchase of a Mountain Flip Tarp Trailer system.

More information

S E L E C T I O N. Arm Curl. User manual

S E L E C T I O N. Arm Curl. User manual S E L E C T I O N T H E S T R E N G T H E V O L U T I O N User manual The identification plate of the and manufacturer, affixed behind the seat, gives the following details: A Name and address of the manufacturer

More information