1 INSTRUCTIONS FOR Door Closer with Hold Open Arms SERIES ADJUSTABLE FROM SIZE THRU 6 FOR INSTALLATION ASSISTANCE CALL SARGENT AT / Installation Instructions based on Application and Arm type Standard Mounting Application - H arm For Standard Application - the Door Closer is mounted on the hinge side of door (see page ) Parallel Arm Application - PH9 Arm For Parallel Arm Application - the Door Closer is mounted on the stop side of door (see page ) Top Jamb Application - H, HZ & HZA Arm For Top Jamb Application - the Door Closer is mounted on the frame on the stop side of the door (see page 6) + LEFT HAND RIGHT HAND or STOP SIDE HINGE SIDE HINGE SIDE STOP SIDE IMPORTANT NOTICE PRE-DRILL / HOLES FOR SELF-TAPPING SCREWS OR TAP #- FOR MACHINE SCREWS A70F

2 A B A) Select closer mounting position based on the maximum door opening, as listed below Note: For ADA applications, select the 60ϒ position B) Prep door and frame Note: /" pilot holes are required when Self Tapping Screws are being used Note: If machine screws are being used, use a drill #6 (.77) and a #- tap B) Install closer body onto the door B) Install Foot & Rod Assembly onto the frames DIM. A DIM. B STANDARD APPLICATION -/" # X / SCREWS OR #- X /8 FLAT HEAD MACHINE SCREW* TOP OF MAXIMUM OPENING DIM. A DIM. B 0ϒ 7 /" /" 60ϒ** /" 0" **If Butt, Frame and Wall Conditions Permit Door Will Open 80ϒ " 7 8" " 8" CLOSER 9 6" 6" 8" MIN TOP RAIL RAILS TO " MAY BE USED PROVIDED DOES NOT PROJECT BEYOND FACE OF C C OF HINGE PIVOT L ILLUSTRATED. SAME DIMENSIONS APPLY FOR LEFT HAND. *SEE PAGE 8 FOR MORTISE NUTS C) Install main arm on the closer with the index mark on the spindle aligning with the # on the main arm (as shown) FACE OF D Attach POSITION OF WHEN ASSEMBLING TO SPINDLE hold open foot to frame with adjusting nut facing down for left hand door or up for right hand door, as illustrated below NUT FACES UP NUT FACES DOWN SHOWN LEFT HAND SHOWN A70F

3 E STANDARD APPLICATION E) Opening the door slightly, slide rod into swivel arm and then close the door E) With the door closed, position the swivel arm so that it is 90º to the door surface E) Tighten the arm screw securely POSITION OF WHEN ASSEMBLING TO SPINDLE SCREW 90ϒ OPEN F Adjust closer as required (See page 8 for details). ACCESSORIES INFORMATION ROD H8 MORTISE FOOT FOR USE WHERE THE STANDARD SURFACE APPLIED FOOT CANNOT BE ATTACHED TO THE TOP CASING OR WHERE APPEARANCE IS A MAJOR FACTOR 0-J COVER PLATE MAY BE USED WHEN CLOSER IS MOUNTED ON A NARROW RAIL TO IMPROVE APPEARANCE WHEN CLOSER IS VIEWED THRU GLASS -W corner bracket closer is mounted on bracket which is attached to door jamb on stop side of door Use this application for exterior doors to keep the closer inside of building; Also may be used to obtain full 80ϒ door opening MORTISE NUTS FOR BOLTING THRU THE ARE FURNISHED WHEN ORDERED A70F

4 MAXIMUM OPENING A70F

5 C INSTRUCTIONS FOR INSTALLING PARALLEL APPLICATION CLOSER MOUNTED ON STOP SIDE OF Select degree of door opening required and attach door closer body to door (long end toward hinge) and foot bracket to frame (according to illustration on A page ). Use templates enclosed for special arms. Mount hold open arm to bracket with adjusting screw facing down for left hand door, facing up for right hand door. NUT FACES UP LEFT HAND SHOWN SHOWN D D) NUT FACES DOWN Install main arm on the closer with the index mark on spindle aligned with the number on the arm Note: Left Hand Doors -align index mark with the # on the main arm (as shown) Note: Right Hand Doors -align index mark with the # on the main arm (as shown) D) This requires the spindle to be rotated D) Rotate the spindle on the bottom of the closer to align index mark with the required number on the arm LEFT HAND PRELOAD Left Hand Door Right Hand Door FOOT BRACKET SCREW OPEN ROD E E) Opening the door slightly, slide rod into swivel arm and then close the door. E) With the door in the closed position, swivel the arm so that the pivot is an -/" off the door surface (as shown below) E) Tighten the arm screw securely PRELOAD LEFT HAND -/" F Adjust closer as required. See page 8 for details. ACCESSORIES INFORMATION FOOT BRACKET SCREW OPEN ROD #H8 MORTISE FOOT /" MIN. 0-D DROP BRACKET CLOSER IS MOUNTED ON PLATE WHEN TOP RAIL IS TOO NARROW 0-J COVER PLATE May be used when closer is mounted on a narrow rail to improve appearance when closer is viewed through glass MORTISE NUTS FOR BOLTING THRU THE ARE FURNISHED WHEN ORDERED #8 MORTISE FOOT For use where the standard surface applied foot cannot be attached to the top casing or where appearance is a major factor A70F

6 TOP JAM APPLICATION INSTALLATION INSTRUCTIONS LEFT HAND ILLUSTRATED SAME DIMENSIONS APPLY FOR MEASURE FROM HINGE C L CLOSER MOUNTED ON ABOVE STOP SIDE OF A HINGE SIDE HINGE SIDE -/8" # x -/" WOOD SCREWS OR #- x /8" FLAT HEAD MACHINE SCREWS STOP SIDE STOP SIDE THIS IS A LEFT HAND THIS IS A CLOSERS ARE NON-HANDED /8" CLOSER TOP OF " DIM "A" -/" -/8" -/" CLOSER FOOT APPLIED TO C L OF CLOSER MOUNTING SCREWS -9/6" " C L OF HINGE PIVOT DEPTH OF REVEAL ASSEMBLY TYPE REVEAL DEPTH DIM. A MAX OPENING RANGE OF OPEN H 0" TO " -/" HZ -/8" TO " 6-/" HZA -/8" TO 8" 7-/" SPRING ADJUSTMENT ADJUST SPRING POWER ACCORDING TO CHART. DECREASE POWER SPRING POWER ADJUSTING NUT + INCREASE POWER CW-CLOCKWISE CCW-COUNTER CLOCKWISE NUMBER OF TURNS OF SPRING POWER ADJUSTING NUT* USE CHART AS GUIDE ONLY. WIDTH (INCHES) OVER 8 APPROXIMATE WEIGHT (POUNDS) CLOSERS - CCW FACTORY** SET - CW -7 CW 7-0 CW * FOR EXTERIOR S USE 0 CLOSERS ONLY. ** CLOSERS ARE FACTORY SET FOR INTERIOR S. * CLOSERS FACTORY** SET -7 CW 7-0 CW FOR EXTERIOR S AND WHERE STRONG DRAFT EXISTS INCREASE SPRING POWER AS NEEDED BY TURNING SPRING ADJUSTING NUT CLOCKWISE. IF NECESSARY, DECREASE SPRING POWER TO MEET REQUIREMENTS BY TURNING SPRING ADJUSTING NUT COUNTER CLOCKWISE. 6 A70F

7 D D) INSTRUCTIONS FOR INSTALLING TOP JAMB Install main arm on the closer with the index mark on spindle aligned with the number on the arm Note: Left Hand Doors -align index mark with the # on the main arm (as shown) Note: Right Hand Doors -align index mark with the # on the main arm (as shown) CLOSER MOUNTED ON ABOVE STOP SIDE OF LEFT HAND LEFT HAND POSITION OF WHEN ASSEMBLING TO SPINDLE E Attach hold open foot to frame with adjusting nut facing down for left hand door or up for right hand door as illustrated below. NUT FACES UP NUT FACES DOWN F SHOWN F) Opening the door slightly, slide rod into swivel arm and then close the door F) With the door closed, position the main arm so it is at 90º to the door surface F) Tighten the arm screw securely LEFT HAND LEFT HAND SHOWN RIGHT ANGLE POSITION OF WHEN ASSEMBLING TO SPINDLE SCREW OPEN ROD G Adjust closer as required. See page 8 for details. A70F 7

8 FINAL ADJUSTMENT AND REGULATING PROCEDURE Minimum recommended door closing time is 6 Seconds for doors opened to 90 degrees. Use /8 hex (Allen) wrench to adjust valves as needed. Closing and latching speeds: Turn valves clockwise to slow down or counterclockwise to speed up door movement. Backcheck: To regulate the intensity of back check action, turn valve clockwise to increase or counterclockwise to decrease checking. CAUTION: Set valve for slight cushioning effect; closer can be damaged if the checking action is too abrupt. Never use the backcheck as a door stop. Always use a door stop to stop the door. Delayed action feature (Optional feature on some models): Delayed action provides slow door closing through the delayed action range. Turn valve clockwise to slow down or counterclockwise to speed up door movement. NUMBER OF TURNS OF SPRING POWER ADJUSTING NUT WIDTH (INCHES) CLOSER -0 TURN nut FACTORY SET 6- TURN nut - -8 TURN nut 7-9 Adjusting door to close due to high draft conditions may exceed ADA standards. Consult local ordinances when fire doors are involved Adjustment hold open arm Slight tightening or loosening of hold open nut changes holding position of door. Note: To protect wall, trim and closer, use a door stop located 0 beyond hold open position but not beyond the max. door opening shown on instructions. OPEN NUT USE /6" WRENCH TO ADJUST NUT COVER DRILL /" DIA. HOLE FOR MOUNTING SCREWS UNREINFORCED STOP MORTISE NUT HEAD DRILL /8" DIA. HOLE FOR MORTISE NUT BODY. For top jamb and corner bracket applications: The door closer foot will be attached to the door in a manner similar to that shown for mounting the closer body.. The appropriate mortise nuts and screws will be suppled based on door thickness. Door construction must provide a bridge type reinforcement to prevent the door rail from collapsing when through-bolts are tightened. INSTALL COVER AS FOLLOWS: FOR STANDARD AND PARALLEL APPLICATION Screw short cover screw (#8- X /6) into top of case approximately turns Assemble plastic support and long cover screw (#8- X /) into bottom of case approximately turns Hold support against case (approximately turns) between flange and screw head Position cover on closer and tighten screws ILLUSTRATED SHORT COVER SCREW GAP PLASTIC SUPPORT AND LONG COVER SCREW INSERT IS REMOVABLE. PLACE IN UNUSED OPENING FOR TOP JAMB APPLICATION Assemble plastic support and long cover screw (#8- X/") into top of case approximately turns Screw short cover screw (#8- X /6") into bottom of case approximately turns Slide cover into gap between flange and screw head. Position cover on closer and tighten screws PLASTIC SUPPORT AND LONG COVER SCREW SHORT COVER SCREW INSERT IS REMOVABLE. PLACE IN UNUSED OPENING 8 A70F

1431 DOOR CLOSER WITH STANDARD DUTY ARMS (WITHOUT HOLD OPEN) INSTALLATION INSTRUCTIONS 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

1431 DOOR CLOSER WITH STANDARD DUTY ARMS (WITHOUT HOLD OPEN) INSTALLATION INSTRUCTIONS 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6 1431 DOOR CLOSER WITH STANDARD DUTY ARMS (WITHOUT HOLD OPEN) INSTALLATION INSTRUCTIONS 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6 FOR INSTALLATION ASSISTANCE, CALL SARGENT AT 1-800-727-5477 www.sargentlock.com

More information

351 DOOR CLOSER WITH DOUBLE LEVER ARM (OP) INSTALLATION INSTRUCTIONS

351 DOOR CLOSER WITH DOUBLE LEVER ARM (OP) INSTALLATION INSTRUCTIONS 2 351 DOOR CLOSER WITH DOUBLE LEVER ARM (OP) INSTALLATION INSTRUCTIONS Strength Adjustable From Size 1 Thru 6 CAUTION: FAILURE TO INSTALL OR ADJUST PROPERLY MAY RESULT IN INJURY OR DAMAGE Auxiliary door

More information

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUH (HOLD OPEN) ARMS

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUH (HOLD OPEN) ARMS SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUH (HOLD OPEN) ARMS Strength Adjustable From Size 1 Thru 6 CAUTION: FAILURE TO INSTALL OR ADJUST PROPERLY MAY RESULT IN INJURY OR DAMAGE. FOR ASSISTANCE,

More information

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUO (JO & JP9) ARMS

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUO (JO & JP9) ARMS SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUO (JO & JP9) ARMS Strength Adjustable From Size 1 Thru 6 CAUTION: FAILURE TO INSTALL OR ADJUST PROPERLY MAY RESULT IN INJURY OR DAMAGE Auxiliary

More information

ASSA ABLOY Series Installation Instructions. Regular Arm. Parallel Arm. Top Jamb Mount. Multi-Sized 1 thru 6 Non-Hold Open and Hold Open Models

ASSA ABLOY Series Installation Instructions. Regular Arm. Parallel Arm. Top Jamb Mount. Multi-Sized 1 thru 6 Non-Hold Open and Hold Open Models 9500 Series Installation Instructions Multi-Sized 1 thru 6 Non-Hold Open and Hold Open Models Regular Pages 5 & 6 Parallel Pages 7 & 8 Top Jamb Mount Pages 9 & 10 IMPORTANT: An improperly installed or

More information

These door closers should NOT be installed on the exposed side (weather side) of exterior doors. WOOD 3/16" 1/4"- 20

These door closers should NOT be installed on the exposed side (weather side) of exterior doors. WOOD 3/16 1/4- 20 Hollow-metal doors require channel or box-type reinforcement when thru-bolt mount is specified. Hold open arms are not permitted on fire doors. Sex-bolts may be required for wood or plastic faced fire

More information

DC3210. Recommended Closer Size

DC3210. Recommended Closer Size Installation Instructions For Non-Hold Open or A Hold Open Arm Option DC3200 Series Multi-Sized thru 6 Regular Arm Universal Door Closers Parallel Arm Jamb Mount See pages 2&3 See pages 4&5 See pages 6&7

More information

316R Series Installation Instructions

316R Series Installation Instructions 316R Series Installation Instructions Multi size 1 thru 6 Non hold open closers CAUTION An incorrectly installed or improperly adjusted closer can cause property damage or personal injury. These instructions

More information

5200 Series Door Closer Installation Instructions

5200 Series Door Closer Installation Instructions 5200 Series Door Closer I-C00187 R2 Regular Arm See Page 2 An incorrectly installed or improperly adjusted door closer can cause property damage or personal injury. These installation instructions should

More information

Installation Instructions. Installation Type

Installation Instructions. Installation Type Installation Instructions 800 & 8050 Slide Track Door Closers Non Hold Open & Hold Open Models Note: Hold open models are not permitted to be installed in Listed fire door assemblies. PULL SIDE MOUNTED

More information

Installation Instructions. Installation Type

Installation Instructions. Installation Type Installation Instructions 300 & 3050 Slide Track Door Closers Non Hold Open & Hold Open Models Note: Hold open models are not permitted to be installed in Listed fire door assemblies. PULL SIDE MOUNTED

More information

Installation Type. Edge of Door. Pull (Hinge) Side Mounted. Hinge Edge of Door. Push (Stop) Side Mounted

Installation Type. Edge of Door. Pull (Hinge) Side Mounted. Hinge Edge of Door. Push (Stop) Side Mounted Installation Instructions CAUTION An incorrectly installed or improperly adjusted door closer can cause property damage or personal injury. These instructions should be followed to avoid the possibility

More information

Installation Instructions

Installation Instructions Installation Instructions CAUTION An incorrectly installed or improperly adjusted door closer can cause property damage or personal injury. These instructions should be followed to avoid the possibility

More information

Regular Arm Installation. Closer mounts on hinge side of door (pull side) See Page 3. Closer cover not shown. Top Jamb Installation

Regular Arm Installation. Closer mounts on hinge side of door (pull side) See Page 3. Closer cover not shown. Top Jamb Installation UNIVERSAL HARDWARE CLOSER UH61 & UH62 STALLATION STRUCTIONS The Professional s Choice MULTI SIZE 1 THRU 6 NON HOLD OPEN CLOSER CAUTION! An incorrectly installed or improperly adjusted door closer can cause

More information

ASSA ABLOY. Model W91 Overhead Concealed Wood Frame Installation Instructions IMPORTANT: BEFORE INSTALLING: TO DETERMINE HAND OF YOUR DOOR:

ASSA ABLOY. Model W91 Overhead Concealed Wood Frame Installation Instructions IMPORTANT: BEFORE INSTALLING: TO DETERMINE HAND OF YOUR DOOR: Model W91 Overhead Concealed s Wood Frame Installation Instructions *Butt or 3/4 Offset Pivot Hung, Multi Sized 1-3, 3-6 Non-Hold Open and Hold Open Models *Other means except 4-1/2" x 4-1/2" or 3/4" offset

More information

INSTRUCTIONS TS93 GSR PT RIGHT HAND ACTIVE LEFT HAND INACTIVE RIGHT HAND INACTIVE LEFT HAND ACTIVE

INSTRUCTIONS TS93 GSR PT RIGHT HAND ACTIVE LEFT HAND INACTIVE RIGHT HAND INACTIVE LEFT HAND ACTIVE INSTRUCTIONS ATTENTION!!! Before you begin, determine installation type (RIGHT HAND ACTIVE OR INACTIVE). Door coordinator suitable for door from 59 to 98 in width. Inactive door width in the case of unequal

More information

TS93 STH. Surface applied door closer. Installation instructions: Pull side door mounted spring track Inverted closer with hold open (STH)

TS93 STH. Surface applied door closer. Installation instructions: Pull side door mounted spring track Inverted closer with hold open (STH) Surface applied door closer Installation instructions: Pull side door mounted spring track Inverted closer with hold open (STH) TABLE OF CONTENTS Closer overall Technical specifications Door template Size

More information

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET HIGH EDGE 2 1/4"(57mm) 03079400070 INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET IMPORTANT: THIS LOCK IS NON-HANDED. LOCK IS FACTORY PACKED PREADJUSTED FOR 1³ ₄" (45mm)

More information

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY. SARGENT Installation Instructions for LP8600 x LR8600 & 12-LP8600 x 12-LR8600 Series Low Profile Panic and Fire Exit Devices on Double Egress & Double Doors or LS8600 & 12-LS8600 Low Profile Exit Device

More information

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver EX88 Interlocking Rim Exit Device Preparation Guide and Installation Instructions Box Contents EX88 Interlocking Rim Exit Device Back Bar Filler Plate Active Push Bar Cylinder and Trim Interface Kit Mounting

More information

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse EX76 Concealed Vertical Rod Exit Device Preparation Guide and Installation Instructions Box Contents EX76 Concealed Vertical Rod Exit Device Back Bar Active Push Bar Filler Plate Door Kit with Templates

More information

800 SERIES. Heavy-Duty Commercial Grade 1 Surface Applied Closers. Standard Features. 3 hours fire rated. openings of the door.

800 SERIES. Heavy-Duty Commercial Grade 1 Surface Applied Closers. Standard Features. 3 hours fire rated. openings of the door. 800 SERIES Heavy-Duty Commercial Grade 1 Surface Applied Closers Standard Features n Performance Complies with ANSI A156.4, Grade 1, 2 million cycles, UL/ULC listed up to 3 hours fire rated n Chassis/Closer

More information

Door Closers. General Information

Door Closers. General Information General Information Hager Companies offers a variety of surface door closers to meet a wide range of applications and uses. Heavy Duty, Grade 1 door closers are ideal for schools, hospitals, and other

More information

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS Ver.2 1300 SERIES CONCEALED VERTICAL ROD DEVICE Top Strike Latch Screws Strike Screws Release Plunger Top Latch Plunger Screws

More information

CRL JACKSON 900 SERIES

CRL JACKSON 900 SERIES INSTALLATION INSTRUCTIONS CRL JACKSON 900 SERIES FLOOR MOUNTED DOOR CLOSERS CENTER HUNG AND OFFSET crlaurence.com crlaurence.com MODEL No. 990 crlaurence.com Phone: (800) 421-6144 Fax: (800) 262-3299 crlaurence.com

More information

Medium HoneyBadger Chase Rack Installation Instructions

Medium HoneyBadger Chase Rack Installation Instructions PREPARATION Medium HoneyBadger Chase Rack Installation Instructions 1. Disconnect the negative terminal on the battery. Park the vehicle on level ground and set the emergency brake. 2. We recommend reading

More information

How To Measure Your Finished Opening

How To Measure Your Finished Opening 3000 Series Bifold Doors How To Measure Your Finished Opening MEASURE FROM RIGHT TO LEFT 2 PLACES (WIDTH) MEASURE FROM TOP TO BOTTOM 2 PLACES (HEIGHT) Tools Required for Assembly: Tools Needed: Phillips

More information

(Wood Door and Frame)

(Wood Door and Frame) ITS961 and ITS965 Closer in Door Track in Frame (Wood Door and Frame) 1 (REFERENCE UNIT CARTON FOR ACCESSORIES AND OPTIONS SUPPLIED) Determine hand of door. Prepare door and frame according to template

More information

ESA-200 Fixed Sidelite

ESA-200 Fixed Sidelite Exterior View Installation Instructions For use with ESA II Controller 1 Tools Required: Suggested Fasteners Required - (Not supplied) Screwdrivers Small Straight (FlatBlade) - for Terminal Block wiring

More information

Installation Instructions 3040 (05-09) 9/16 9/ /32 9/32. Checking Adjustments

Installation Instructions 3040 (05-09) 9/16 9/ /32 9/32. Checking Adjustments RIXSON ASSA ALOY Template 3/4 1/8 2- R. Max 1-7/16 1-1/32 2-2-3/4 7/8 Dia. C L Spindle Installation Instructions 3040 (05-09) 9/16 9/32 1/16 Finish Plate 1/4 1-1/4 Dia. 340 TOP PIVOT PIVOT SHOWN ENGAGED

More information

*18758* 2030 Series. 1 Installation. 2 Adjustment. 3 Hold Open Information BACKCHECK. * Hold open tracks. Installation Instructions

*18758* 2030 Series. 1 Installation. 2 Adjustment. 3 Hold Open Information BACKCHECK. * Hold open tracks. Installation Instructions 18758 18758 No maintenance required. 2035 EN 4 1 Installation 1a The hand of the door and the closer must be the same. RH or LH will be stamped on the mounting plate. See the proper template for your application.

More information

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device *911403-00* 911403-00 Surface Vertical Rod Exit Device 33/3527A Installation Instructions Devices covered by these instructions: 33/3527A Surface Vertical Rod Exit Device 33/3527A-F (Fire) Surface Vertical

More information

FRAME PREPARATION 3900/8900 SURFACE LATCH CONCEALED ROD EXIT DEVICE INSTALLATION INSTRUCTIONS HOW TO FIND BACKSET. Date: Appvd: *13/16 2 3/4" 3/4 HOLE

FRAME PREPARATION 3900/8900 SURFACE LATCH CONCEALED ROD EXIT DEVICE INSTALLATION INSTRUCTIONS HOW TO FIND BACKSET. Date: Appvd: *13/16 2 3/4 3/4 HOLE FRAME PREPARATION 3/4 3/4 HEADER STRIKE STRIKE STOP FRAME 13/16 13/16 RHR LHR INTERIOR FACE OF LHR INTERIOR FACE OF RHR STRIKE POST *13/16 * MEASURED FROM THE INTERIOR SURFACE. BE SURE TO ADJUST FOR SILENCERS

More information

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2 911404-00 Concealed Vertical Rod Exit Device 33/3547A Installation Instructions Devices covered by these instructions: 33/3547A and 33/3548A Concealed Vertical Rod Exit Device 33/3547A-F and 33/3548A-F

More information

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING JANUARY, 2014 1 INSTALLATION Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING INSTRUCTIONS 2 FRAME ASSEMBLY JANUARY, 2014 601442 SHEAR BLOCK BALL BEARING NRP BUTT (FACTORY APPLIED

More information

ESA-300 Full Breakout

ESA-300 Full Breakout Interior View 0 Installation Instructions For use with ESA II Controler DORMA AUTOMATICS, Inc. 94 Sherwood Drive Toll-Free: 877-67-6 DL844-00 Lake Bluff, IL 60044 Fax: 877-4-7999 Rev. /07 Tools Required:

More information

CONCEALED VERTICAL ROD PANIC EXIT DEVICE

CONCEALED VERTICAL ROD PANIC EXIT DEVICE INSTALLATION INSTRUCTIONS CRL JACKSON 1085-1085P CONCEALED VERTICAL ROD PANIC EXIT DEVICE crlaurence.com Phone: (800) 421-6144 Fax: (866) 921-0531 crlaurence.com usalum.com crl-arch.com 11M0236 ORDER OF

More information

Installation Instructions

Installation Instructions VON DUPRIN Installation Instructions 98/9947WDC Concealed Vertical Rod Exit Device Wood Door Applications Devices covered by these instructions: 98/9947WDC Concealed Vertical Rod Device 98/9947WDC-F (Fire)

More information

Installation Instructions 50 (06-09) 1-15/32 15/32 21/32. 1/4-20 x 5/8" FHMS or #14 x 1/2" FHWS 1/16 1/4. Floor Plate

Installation Instructions 50 (06-09) 1-15/32 15/32 21/32. 1/4-20 x 5/8 FHMS or #14 x 1/2 FHWS 1/16 1/4. Floor Plate RIXSON ASSA ABLOY 3/4 Template Jamb 1/8 2- R. Max. 1-7/16 1-1/32 2-2-3/4 7/8 Dia. C L 1-1/4 Dia. Installation Instructions 50 (06-09) Finish Plate 340 TOP PIVOT Pivot Shown Engaged 9/16 1/16 1/4 1-15/32

More information

1. Begin by rolling your window up all the way 2. Remove your door and window handles by unscrewing the flat head set screws behind each handle.

1. Begin by rolling your window up all the way 2. Remove your door and window handles by unscrewing the flat head set screws behind each handle. 1. Begin by rolling your window up all the way 2. Remove your door and window handles by unscrewing the flat head set screws behind each handle. 3. Remove the 12 screws that attach the steel interior door

More information

INSTALLATION INSTRUCTIONS VENETIAN 84" SLIDING SHOWER DOOR SYSTEM (180º INSTALLATION)

INSTALLATION INSTRUCTIONS VENETIAN 84 SLIDING SHOWER DOOR SYSTEM (180º INSTALLATION) INSTALLATION INSTRUCTIONS VENETIAN 84" SLIDING SHOWER DO SYSTEM (180º INSTALLATION) 28539 Industry Drive, Valencia, CA 91355 Toll Free Phone: (877) 728-3874 Toll Free Fax: (888) 440-9567 Phone: (661) 775-1675

More information

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device 911375-00 Surface Vertical Rod Exit Device 98/9927 Installation Instructions Devices covered by these instructions: 98/9927 Surface Vertical Rod Exit Device 98/9927-F (Fire) Surface Vertical Rod Exit Device

More information

ED5800 (A) Series. Installation Instructions. Concealed Vertical Rod. Exit Device WARNING

ED5800 (A) Series. Installation Instructions. Concealed Vertical Rod. Exit Device WARNING Strike Shim (2) Supplied Strike Plate (3) 10-24 x 3/4" PFHMS (6) 10-24 x 1/2" PFHMS Top Latch TopTube Concealed Vertical Rod Exit Device Important: For use with metal doors only. Device is packed ready

More information

ESA-100 Fixed Sidelite/Non Breakout

ESA-100 Fixed Sidelite/Non Breakout /Non Breakout Exterior View Installation Instructions For use with ESA II Controller 1 Tools Required: Suggested Fasteners Required - (Not supplied) Screwdrivers Small Straight (FlatBlade) - for Terminal

More information

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110 INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110 The KWE dual swing arm wall mount is designed to provide a broad range of viewing for Small

More information

1530(F) Mortise Exit Devices Installation Instructions

1530(F) Mortise Exit Devices Installation Instructions 1530(F) Mortise Exit Devices Installation Instructions Singe Doors or Pairs (2) 12-12-24 PFHUM/WS 798 Universal Strike Standard Device Package Devices are packed ready for application reinforced metal

More information

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill DEVICES COVERED IN THIS DOCUMENT: 4700S Surface Vertical Rod Device 4700SF Fire Exit Surface Vertical Rod Device TOOLS REQUIRED Metal Wood Wood and Metal Screws Sex Bolts #7 Drill ¼ -20 Tap #16 Drill #12-24

More information

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device 911402-00 Rim Exit Device 33/35A Series Installation Instructions Devices covered by these instructions: 33/35A Rim Exit Device CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

More information

PFD-22 Top OHC Patch Fitting & PFD-10 Bottom Patch Fitting Installation Instructions

PFD-22 Top OHC Patch Fitting & PFD-10 Bottom Patch Fitting Installation Instructions Top OHC Patch Fitting & Bottom Patch Fitting Installation Instructions For Installation Assistance, Call 855.594.6989 www.assaabloyglass.us Tools Needed: Torque Wrench and Bit 5mm Allen Wrench 6 7 /16"

More information

Fig. 2 DORMA-Glas Stand/Issue 02/03 Seite/Page 1/7

Fig. 2 DORMA-Glas Stand/Issue 02/03 Seite/Page 1/7 FSW Installation instructions Track rail 75 x 72 mm 1. Ceiling substructure and installation of the track rail (Fig. 1): The track rail must be bolted over its entire length (including the stacking track

More information

Shim (2) Supplied. Strike Plate. (3) x 5/8" PFHMS or 10 x 1" PFHWS. Top Latch. (3) x 1/4" PRHMS. Latch Cover. (2) 8 x 3/8" PFH AB SMS

Shim (2) Supplied. Strike Plate. (3) x 5/8 PFHMS or 10 x 1 PFHWS. Top Latch. (3) x 1/4 PRHMS. Latch Cover. (2) 8 x 3/8 PFH AB SMS Installation Instructions ED5400 (A) Series ED5470 (B) Series Surface Vertical Rod Exit Devices Strike Angle Must Engage Strike Top Strike 10-24 PFHMS Top Bracket and Strike required for ED5470. Shim (2)

More information

4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162

4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162 DEVICES COVERED IN THIS DOCUMENT: 4600 Series Rim Panic Narrow Stile Exit Device 4600 Series Rim Fire Narrow Stile Exit Device OVERVIEW Outside of Door RHR LHR Inside of Door APPLICATIONS 4950 BLADE STOP

More information

RH-412 STEEL DOORS INSTALLATION INSTRUCTIONS

RH-412 STEEL DOORS INSTALLATION INSTRUCTIONS RH-412 STEEL DOORS INSTALLATION INSTRUCTIONS By following the steps outlined below, the assembly, installation and adjustment of the steel doors, will be a simple process. Let s start with the Driver Side.

More information

INSTALLATION INSTRUCTIONS RH 412 STEEL DOORS

INSTALLATION INSTRUCTIONS RH 412 STEEL DOORS By following the steps outlined below, the assembly, installation and adjustment of the steel doors, will be a simple process. Let s start with the Driver Side. Note: Having the hood open makes the job

More information

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS PACKAGE CONTENTS PRODUCT MUST BE INSTALLED ACCORDING TO ALL APPLICABLE BUILDING AND LIFE SAFETY CODES TEMPLATE INSTALLATION INSTRUCTIONS STRIKE HAND TOOL 5/32 HEX KEY ROD END CAPS EXIT DEVICE CRANK ARM

More information

ICU TRACKLESS SLIDING DOOR

ICU TRACKLESS SLIDING DOOR Interior View 0 Installation Instructions Tools Required: Screwdrivers Small Straight (Flat Blade) - for Terminal Block wiring # Phillips (Crosspoint) - for various #8, #0, and #4 screws Wrenches / Sockets

More information

FINISH GROUPS #17 GRP #17 CLEAR

FINISH GROUPS #17 GRP #17 CLEAR EFFECTIVE FEBRUARY 1, 2018 CONTENTS A3/1 CONTENTS SECTION A3...DOOR CLOSERS PAGE SURFACE MOUNTED CLOSERS... A3/2 A3/3 CALIBRE TM CLOSERS... A3/4 INTERNATIONAL CONCEALED CLOSERS... A3/5 CONCEALED CLOSER

More information

EXIT DEVICE OPERATION FIRE DOOR LABELS, STRIKES AND FRAME SCREWS FOR INFORMATION CALL OR VISIT RITEDOOR.COM

EXIT DEVICE OPERATION FIRE DOOR LABELS, STRIKES AND FRAME SCREWS FOR INFORMATION CALL OR VISIT RITEDOOR.COM RECORD & LABELS WHAT THIS OWNER'S CAN DO FOR YOU It explains exactly how The Rite Door operates. It explains periodic maintenance requirements necessary to assure reliable operation. It explains simple

More information

TOOLS REQUIRED FOR ASSEMBLY. Rubber Mallet or Plastic Tip Hammer PARTS REQUIRED FOR ASSEMBLY OF SINGLE ENTRY STARTER.

TOOLS REQUIRED FOR ASSEMBLY. Rubber Mallet or Plastic Tip Hammer PARTS REQUIRED FOR ASSEMBLY OF SINGLE ENTRY STARTER. TOOLS REQUIRED FOR ASSEMBLY Rubber Mallet or Plastic Tip Hammer Top Cover Support PARTS REQUIRED FOR ASSEMBLY OF SINGLE ENTRY STARTER Back Stop Divider Closed 'L' Upright Slotted Reinforcement Support

More information

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS MantelMount TMA Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS TM Thank you for choosing the MantelMount television wall mount. Please read this entire manual before

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Special-Lite Restroom Partitions IMPORTANT - BEFORE YOU START... 1. Read through these installation instructions first to understand the order of work. 2. Check all components

More information

Kai Installation Instructions

Kai Installation Instructions Kai Installation Instructions Before Beginning Installation Read through the entire instruction thoroughly A minimum of 2 people are required for this assembly These instructions reflect typical assemblies;

More information

Entry Mortise Handleset

Entry Mortise Handleset 1. Pencil 2. No. 2 and No. 3 Phillips Head Screwdrivers 3. No. 1 and No. 2 Slotted Screw Drivers 4. 1/8" Allen Head Wrench 5. 3/4" Wood Chisel or Corner Chisel 6. Measuring Device 7. Lock Mortising Tool

More information

INSTALLATION INSTRUCTIONS FOR PLASCORE NARROW STILE DOORS

INSTALLATION INSTRUCTIONS FOR PLASCORE NARROW STILE DOORS INSTALLATION INSTRUCTIONS FOR PLASCORE NARROW STILE DOORS The following information is provided by Plascore, Inc., as a general guideline for the installation of the Plascore Narrow Stile Door and Jamb

More information

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42 - 60 Plasma Screens Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens Models: PLAV 70-UNL, PLAV 70-UNL-S PLAV 70-UNLP, PLAV 70-UNLP-S R This product is UL Listed. It must be

More information

Wooden Frame Type Instruction Manual

Wooden Frame Type Instruction Manual Wooden Frame TypeInstruction Manual Thank you for selecting our product. Before starting installation, please read this manual thoroughly to ensure correct installation. Please keep this manual at hand

More information

IDR assembly instructions:

IDR assembly instructions: IDR assembly instructions: Required Tools: 2 X 12mm Open End Wrench 14mm open end wrench #2 Phillips Head Screw Driver (Drill with adjustable torque clutch recommended) 8mm nut driver (Supplied in IDR-AK)

More information

Installation Instruction

Installation Instruction Tools Needed for Assembly Stud finder (for wood stud wall) Pencil Mark Electric drill Wood Stud Wall Installation Step 1. Locate the Wood Studs Installation Instruction Drill bit (for wood stud wall) Masonry

More information

Step by Step Installation Instructions. Poly Shutters. Customer Service or visit us online at smithandnoble.com

Step by Step Installation Instructions. Poly Shutters. Customer Service or visit us online at smithandnoble.com Step by Step Installation Instructions Poly Shutters Customer Service 800.248.8888 or visit us online at smithandnoble.com Thank you for purchasing from smith+noble. Your new window treatments have been

More information

Semi-Frameless Hinged Door With Panel And Return

Semi-Frameless Hinged Door With Panel And Return 202 Anderson Ave., Belvue, KS 66407 Phone: 800-669-9867 Fax: 800-393-6699 www.onyxcollection.com 800-643-1514 www.alumaxbath.com Semi-Frameless Hinged Door With Panel And Return Full Showers with Return

More information

White Quail Auto Trap

White Quail Auto Trap White Quail Auto Trap WARNING SAFETY, STORAGE & USE IF THE MAIN SPRING IS ATTACHED AND THE TRAP ARM IS IN THE 6 O CLOCK POSITION, THE TRAP IS ARMED AND EXTREME CAUTION IS REQUIRED. TO DISARM, TURN THE

More information

Preference Collection 5580 Treatment Console INSTALLATION GUIDE

Preference Collection 5580 Treatment Console INSTALLATION GUIDE Preference Collection 5580 Treatment Console INSTALLATION GUIDE 0 WARNING Failure to install the 5580 as described in this installation guide may cause the unit to collapse, resulting in serious injury

More information

Preference Collection and Treatment Console INSTALLATION GUIDE

Preference Collection and Treatment Console INSTALLATION GUIDE Preference Collection 5580.69 and 5580.96 Treatment Console INSTALLATION GUIDE WARNING Failure to install the 5580 as described in this installation guide may cause the unit to collapse, resulting in serious

More information

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only) List of Contents Quantity Description 12 #10 x 1 ½ Flat Head Phillips Screw (see pg. 2) 2 #10 x ½ Pan Head Phillips Screw (see pg. 2) 8 ¼ x 2 ½ Lag Bolt (see pg. 2) 7 ¼ 20 x 5 / 8 Hex Head Bolt (see pg.

More information

SALICE AIR TEMPLATE KIT

SALICE AIR TEMPLATE KIT SALICE AIR TEMPLATE KIT There are two separate templates available for the machining of the AIR hinge; one is used for machining both the top and bottom of the door while the other is used for machining

More information

Atrium Patio Door Field Service Manual

Atrium Patio Door Field Service Manual Atrium Patio Door Field Service Manual December 2005 Table of contents Service Agreement Pg 2 Release Agreement Pg 5 Inspection form Pg 6 Warranty Pg 8 Replacing swing panel Pg 12 Replacing sliding panel

More information

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42 - 60 Plasma Screens Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens Models: PLAV 70-UNL, PLAV 70-UNL-S PLAV 70-UNLP, PLAV 70-UNLP-S R This product is UL Listed. It must be

More information

MCH42 / MCH48 MODULAR SERIES 2400/3000 CORNER HUTCH

MCH42 / MCH48 MODULAR SERIES 2400/3000 CORNER HUTCH / MODULAR SERIES 2400/3000 CORNER HUTCH IMPORTANT! Assembly may require the assistance of another person. Before you begin assembly: READ THE DIRECTIONS all the way through one time. This will speed up

More information

Rim-Lock Door Set Installation Instructions

Rim-Lock Door Set Installation Instructions Rim-Lock Door Set Installation Instructions Let s get started Check Your Parts List Two Doorknobs with Set Screws B. Doorknob Spindle C. Rim Lock with Mounting Screws D. Keeper with Mounting Screws E.

More information

ICU TRACK SLIDING DOOR

ICU TRACK SLIDING DOOR Interior View 0 Installation Instructions Tools Required: Screwdrivers Small Straight (Flat Blade) - for Terminal Block wiring # Phillips (Crosspoint) - for various #8, #0, and # screws Wrenches / Sockets

More information

Door Controls. Table of Contents

Door Controls. Table of Contents Door Controls Hager Companies offers a comprehensive line of door control products designed and manufactured to meet a wide range of applications and uses. From humble beginnings in 1849 as a forger of

More information

Privacy Wall Glass Selections - Polished Edge Slider Door

Privacy Wall Glass Selections - Polished Edge Slider Door Privacy Wall Glass Selections - Polished Edge Slider Door 3/6" HEX BIT PUTTY KNIFE #2 ACR BIT SUCTION CUP HOLDERS DOOR LEAF: Satin Tempered Clear Tempered LOCTITE 425 SIDE LIGHT ETCHED GLASS STYLES: Satin

More information

User Instructions Multiline Otter Scoreboard Caddy Assembly

User Instructions Multiline Otter Scoreboard Caddy Assembly List of parts: User Instructions Multiline Otter Scoreboard Caddy Assembly Single Caddy Double Caddy 1 1 Base assembly with attached wheels 2 4 1 1 2 4 4 8 10 20 12 Uprights (60 or 74 aluminum extrusion)

More information

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas) List of Contents Quantity Description 12 #10 x 1 ½ Flat Head Phillips Screw (see pg. 2) 2 #10 x ½ Pan Head Phillips Screw (see pg. 2) 8 ¼ x 2 ½ Lag Bolt (see pg. 2) 7 ¼ 20 x 5 / 8 Hex Head Bolt (see pg.

More information

GATE INSTALLATION INSTRUCTIONS

GATE INSTALLATION INSTRUCTIONS GATE INSTALLATION INSTRUCTIONS 1) Ensure posts for gate are fully installed. Posts need to be securely fastened to decking or concrete such that they will not sag with weight of the gate. For a single

More information

Note: The dimensions of the Template are shown in inches. See attached page for the Metric Conversion Table for millimeters.

Note: The dimensions of the Template are shown in inches. See attached page for the Metric Conversion Table for millimeters. 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com These instructions are presented a in step by step sequence. Please read it through before installation.

More information

Calf-Tel Pen System Assembly Instructions

Calf-Tel Pen System Assembly Instructions Calf-Tel Pen System Assembly Instructions (Instructions work for 4, 6, and the 7 Pen Systems) 1 ASSEMBLY OF PEN FRONT AND WALLS START THE ASSEMBLY BY LINING UP THE TWO UNI-DIRECTIONAL ARROWS IN THE TOP,

More information

POWER PET. Low-E Automatic Patio Pet Door Installation and Operating Instructions

POWER PET. Low-E Automatic Patio Pet Door Installation and Operating Instructions POWER PET Low-E Automatic Patio Pet Door Installation and Operating Instructions Power Pet, Regular Height, Patio Door Assembly Steps Estimated assembly time: Under 1 hour STEP 1: Assemble the tools you

More information

Quill Stop V2 Installation Guide 11/16/2014

Quill Stop V2 Installation Guide 11/16/2014 Thank you for purchasing the Quill Stop for the Sieg X3 (Grizzly G0463) and SX3 (Grizzly G0619) mills. Your feedback is always appreciated. Please email questions and comments to gregpriest@cox.net. What

More information

ASSEMBLY AND ADJUSTMENT

ASSEMBLY AND ADJUSTMENT EPPA MONITOR ARM EPPA Rev A 10/17 Model EPPA-XXX ASSEMBLY AND ADJUSTMENT EPPA MONITOR ARM PARTS AND TOOLS PLEASE REVIEW these instructions before beginning the assembly and adjustment procedures. Check

More information

Preference Collection 5531 Accessory Console I NSTALLATION GUIDE

Preference Collection 5531 Accessory Console I NSTALLATION GUIDE Preference Collection 5531 Accessory Console I NSTALLATION GUIDE WARNING Failure to install the 5531 as described in this installation guide may cause the unit to collapse, resulting in serious injury

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS HIGH PRESSUE LAMINATE (HPL) TOILET PARTITIONS 1030 TrimLineSeries 1040 DesignerSeries Includes continuous hardware option.65. IMPORTANT: Storage and Handling Information on last

More information

Installation/Care/Use Manual Soft Sides Freeze Resistant Fountain

Installation/Care/Use Manual Soft Sides Freeze Resistant Fountain Installation/Care/Use Manual Soft Sides Freeze Resistant Fountain EDFP217FPC Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION.

More information

Phone # La Jolla Doors. Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels

Phone # La Jolla Doors. Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels Phone # 800-440-8785 www.lajolladoors.com La Jolla Doors Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels Thank you for choosing La Jolla Doors In this manual you will

More information

western window systems westernwindowsystems.com installation instructions non-pocket 2-1/4 panels

western window systems westernwindowsystems.com installation instructions non-pocket 2-1/4 panels series 2600 multi-slide non-pocket 2-1/4 panels windowsystems.com windowsystems.com movement, which can cause warping and other problems. Frame kit components: Each door will have a head assembly, a threshold

More information

7110(F), 7170(F)(LBR) Surface Vertical Rod Exit Device Series Installation Instructions

7110(F), 7170(F)(LBR) Surface Vertical Rod Exit Device Series Installation Instructions 7110(F), 7170(F)(LBR) Surface Vertical Rod Exit Device Series Installation Instructions Shim (2) Supplied Strike Plate 791 Strike (3) 10-24 x 3/4 (19mm) PFHMS Strike Angle Must Engage Strike 12-24 FHPMS

More information

TITAN2-EDGE Public Access Computer Station Dual Track

TITAN2-EDGE Public Access Computer Station Dual Track TITAN2-EDGE Public Access Computer Station Dual Track TITAN2-EDGE Rev A 6/17 Model TITAN2-EDGE ASSEMBLY AND ADJUSTMENT TITAN2-EDGE PARTS AND TOOLS PLEASE REVIEW these instructions before beginning the

More information

ED5200S(A) Series ED5200S(A) Series x M107 Windstorm Series SecureBolt Exit Device

ED5200S(A) Series ED5200S(A) Series x M107 Windstorm Series SecureBolt Exit Device ED5200S(A) Series ED5200S(A) Series x M107 Windstorm Series SecureBolt Exit Device Installation Instructions FM532 3/11 (Single Doors or Pairs with Mullion) For Doors of Either Hand In U.S.: Corbin Russwin,

More information

HIT-30 ALUMINUM DOOR SERIES OWNERS MANUAL

HIT-30 ALUMINUM DOOR SERIES OWNERS MANUAL HIT-30 ALUMINUM DOOR SERIES OWNERS MANUAL INSTALL LOCKS LATCHES LEVERS / PADDLES INDICATORS STRIKES Every Installation Is A Self-Portrait Of The Person Who Did It! Autograph Your Work With Excellence!

More information

Entry Mortise Lock Set Lever to Lever

Entry Mortise Lock Set Lever to Lever Entry Mortise Lock Set Lever to Lever 1 Lever 2 Escutcheon 3 Turn Piece 4 Mortise Lock 5 Scalp 6 Mortise Lock Strike 7 Mortise Lock Dust Box 8 Mortise Cylinder 9 Cylinder Swing Cover 10 Spindle 11 Spindle

More information