1-Way Vertical Joining (Pages 2-22) 1-Way Horizontal Joining (Pages 23-44)

Size: px
Start display at page:

Download "1-Way Vertical Joining (Pages 2-22) 1-Way Horizontal Joining (Pages 23-44)"

Transcription

1 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) or (1-Way Horizontal Joining) 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) or (1-Way Horizontal Joining) for Andersen 400 Series Tilt-Wash Double-Hung, Picture, and Transom Windows and Narroline Circle Top Windows with Stormwatch Protection. 1-Way Vertical Joining (Pages 2-22) 1-Way Horizontal Joining (Pages 23-44) Not all parts included will be used. Check specific horizontal or vertical joining section in this guide for parts needed. Properly dispose of unused parts. Andersen and all other marks where denoted are marks of Andersen Corporation Andersen Corporation. All rights reserved BD Revised 11/24/08

2 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) for Andersen 400 Series Tilt-Wash Double-Hung, Picture, and Transom Windows with Stormwatch Protection Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance are essential if the benefits of your Andersen product are to be fully attained. Therefore, please read and follow this Instruction Guide completely. If your abilities do not match this procedure s requirements, contact an experienced contractor. You may direct any questions about this or other products to your local Andersen dealer, found in the Yellow Pages under Windows or call Andersen WindowCare service center at Monday through Friday, 7 a.m. to 7 p.m. Central Time and Saturday, 8 a.m. to 4 p.m. Central Time. Thank you for choosing Andersen. Impact Resistant Glass used by Andersen is not hurricane proof or shatter proof, and may not offer a high level of security. Proper installation of window and door units with impact resistant glass is as important to product performance as the glass. Every assembly and installation is different (windloads, structural support, etc.), and Andersen strongly recommends consultation with an Andersen supplier or an experienced contractor, architect, or structural engineer prior to the assembly and installation of any Andersen product. Andersen has no responsibility in regard to the post-manufactured assembly and installation of Andersen products. Use caution when working at elevated heights and around unit openings. Follow manufacturer s instructions for safe use of ladder and/or scaffolding. Failure to do so may result in injury or death. Follow manufacturer s instructions for safe operation of hand/power tools. Always wear safety glasses. Failure to do so may result in injury and/ or product damage. Windows and doors can be heavy. Use safe lifting techniques and a reasonable number of people with enough strength to lift, carry and install window and door products to avoid injury and/or product damage. Unless specifically ordered, Andersen windows and doors are not equipped with safety glass, and if broken, could fragment causing injury. Many laws and building codes require safety glass in locations adjacent to or near doors. Andersen windows are available with safety glass that may reduce the likelihood of injury when broken. Information on safety glass is available from your local Andersen dealer. Andersen Installation Flanges DO NOT take the place of standard window and door flashing. Unit must be properly flashed and sealed with sealant, and full width drip cap for protection against water and air infiltration. Use non-reflective flashings. Highly reflective flashing tapes can raise the surface temperature of the vinyl to the point where vinyl deformation and product damage may occur. Do not apply any type of film to glass. Thermal stress conditions resulting in glass damage could occur. Use of movable insulating materials such as window coverings, shutters, and other shading devices may damage glass and/or vinyl. In addition, excessive condensation may result causing deterioration of windows and doors. Andersen and all other marks where denoted are trademarks of Andersen Corporation Andersen Corporation. All rights reserved. 2 Revised 11/24/08

3 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) Metal fasteners and other hardware components may corrode when exposed to preservative treated and fireretardant treated lumber. Obtain and use the appropriate metal fasteners and hardware as called out by the installation guide to fasten unit to any rough opening made from pressure treated and fire-retardant treated lumber. Failure to use the appropriate materials for the installation may cause a failure resulting in injury, property or product damage. Use this guide to join two or more units vertically. Exterior Views Parts Included (1) Instruction Guide (1) Gusset Plate (1) Gusset Plate (1) 3/4" LVL Joining Strip (1) Exterior Trim Strip (1) Installation Screw Pack Additional Parts Required Drip Cap (full width) Component Identification Gusset Plate Gusset Plate Tools and Supplies Safety Glasses Tape Measure Pencil Level Hammer Clamps Power Drill Caulk Gun Hack Saw Wood Block Sealant Vise Grip/Pliers Small Pry Bar 3/8" Wood Shims Power Saw Small File/Rasp 3/32" Drill Bit Utility Knife Isopropyl Alcohol 3/4" LVL Joining Strip Exterior Trim Strip 3

4 1. Verify that LVL Joining is Adequate for Your Installation Calculate the average adjacent unit dimension ((A + B) 2). Determine the mullion length (C). Use the windload chart below to cross reference the average adjacent unit dimension with the mullion length to determine the windload performance of your combination. Be sure that this performance is adequate for your installation requirements. Refer to the Combination Design section in the Andersen Product Guide for Professionals for further information. 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) Double-Wide Unit Exterior View Exterior View Picture Window with Flanking Units Design Windload PSF Table for 3/4" LVL Reinforced Joining Type of Combination: Vertical Joining For Combining: Tilt-Wash Double-Hung, Transom, or Picture Windows Average Adjacent Unit Dimension (A + B) 2 = 6' 1" (A + B) 2 = 5' 6" (A + B) 2 = 5' 1" (A + B) 2 = 4' 6" (A + B) 2 = 4' 1" (A + B) 2 = 3' 6" PSF (A + B) 2 = 3' 1" (A + B) 2 = 2' 6" (A + B) 2 = 2' 1" (A + B) 2 = 1' 6" C = (mullion length) 5' 6" or less 6' 1" 4

5 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) 2. Prepare Rough Opening Determine rough opening width for multiple units using the formula: rough opening width = 3/8" (shim) + total unit width(s) + 3/4" for each join (LVL Joining Strip) + 3/8" (shim). Determine rough opening height using the formula: rough opening height = 3/8" (shim) + unit height + 3/8" (head clearance). Check rough opening for plumb and level. If rough opening is not plumb or level, correct as necessary. Check opening for square by measuring diagonally, upper left to lower right and upper right to lower left corner. If measurements are within 1/8", opening is square. If rough opening is not square, correct as necessary. Tape Measure Level Exterior View 3. Prepare Units Place units exterior side up on a clean, flat work surface. Remove Installation Flange from sides of units to be joined. Remove Installation Flange Remove and discard protruding 3" screw from Outer Frame Member Bracket on Tilt-Wash Unit sides to be joined. Remove banding tape from double-hung units. For Extension Jamb application, see step 17. 3/4" LVL Joining Strip Tilt-Wash Unit Gusset Plate Picture Unit Exterior Side Up Outer Frame Member Bracket (Remove 3" Screw) Gusset Plate Remove Installation Flange Picture Window with Flanking Units Double-Wide Unit Exterior Side Up Exterior Side Up Triple-Wide Unit 5

6 4. Prepare 3/4" LVL Joining Strip(s) Square end cut 3/4" LVL Joining Strip 3/4" shorter than length of units to be joined. Replicate the factory end by removing 1-1/2" of aluminum leg from each side, at ends, of 3/4" LVL Joining Strip using a vise grip/pliers. 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) Hack Saw 3/4" LVL Joining Strip Aluminum Leg (Cut and Remove) 3/4" LVL Joining Strip Aluminum Leg (Remove) Vise Grip 1-1/2" 5. Attach 3/4" LVL Joining Strips Place locator tab of 3/4" LVL Joining Strip into kerf on side jamb and center on unit. 3/4" LVL Joining Strip must not extend into head jamb dados. Fasten using two (2) #8-18 x 1-3/8" screws. #8-18 x 1-3/8" Screw Exterior Side Up Locator Tab Side Jamb Kerf 3/4" LVL Joining Strip Cross Section Detail 6

7 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) 6. Join Units Exterior nose of units and side jambs must be flush full length. If not flush, there will not be a proper seal and water infiltration may result. DO NOT over tighten clamps, excess tightening of clamps may mar surface. Upper unit Installation Flange must overlap lower unit Installation Flange to the exterior on horizontal joins. Failure to do so may adversely affect product performance. #10 x 2-1/2" Screw Clamp Exterior Side Up Slide units together. Exterior nose of units and side jambs must be flush full length. Clamp units together, from the exterior, using clamps and surface protectors. Drill 3/32" holes, at 22 on the Outer Frame Member, 4" from head and sill, no deeper than 2-1/4". Offset holes 1/4" on adjacent units to avoid screw interference. Fasten units using #10 x 2-1/2" color matched screws with ring washers. Ring Washer #10 x 2-1/2" Screw Outer Frame Member 22º 22º Drilled Hole Drilled Hole Cross Section Detail Double-Hung to Double-Hung Ring Washer Outer Frame Member 22º 22º Drilled Hole Drilled Hole Cross Section Detail Picture Window to Double-Hung 7

8 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) 6. Join Units (Continued) Double-Hung to Double-Hung Combination On one of the units being joined move the 1-1/4" screw remaining in the Checkrail Bracket from its current hole to the other hole in the Checkrail Bracket where the 3" screw was removed in Step 3. Moving this screw will make sure that the screws on the Checkrail Bracket on the adjacent unit do not interfere with the screws on this Checkrail Bracket. Drill a 3/32" hole, no deeper than 2-1/2" deep, in the hole where the screw was just removed. Fasten the remaining Checkrail Bracket hole with a #10 x 2-1/2" color matched screw. Place a #10 x 2-1/2" color matched screw in the empty Checkrail Bracket hole on the other unit. #10 x 2-1/2" Screw Clamp Exterior Side Up #10 x 2-1/2" Screw 1-1/4" Screw Checkrail Bracket Picture Window to Double-Hung Combination Drill 3/32" hole, at 22 on the Outer Frame Member of Picture Unit, at the center of side jambs, on joined sides. DO NOT drill deeper than 2-1/2". Offset hole 1/4" from 2-1/2" screw in the Tilt-Wash Unit Checkrail Bracket to avoid screw interference. Fasten unit using #10 x 2-1/2" color matched screws with ring washers. Fasten Tilt-Wash Unit using #10 x 2-1/2" Color Matched Screw where the 3" screw was removed in Step 3. #10 x 2-1/2" Screw Clamp Exterior Side Up Transom Units No additional fasteners needed for vertical, 1-way, transom joins. 8

9 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) 7. Attach Gusset Plates Position sill Gusset Plate on sill centered over unit joins and fasten using (12) #8 x 1" Screws. Position head Gusset Plate in jamb dado centered over unit joins and fasten using (12) #8 x 5/8" Screws. Gusset Plate #8 x 1" Screws Gusset Plate #8 x 1" Screws Exterior Side Up #8 x 5/8" Screws Gusset Plate 8. Apply Exterior Trim Strip Clean surface of Trim Strip Receivers and vinyl surface of unit with isopropyl alcohol for proper adhesion. Apply a continuous 1/8" bead of sealant along joins of Trim Strip Receivers and jambs. Caulk Gun Initial positioning of Exterior Trim Strip is important because it is very difficult to remove once inserted. Exterior Side Up Cut Exterior Trim Strip to match unit length. Position edge of Exterior Trim Strip flush with unit edge and press in with thumbs from one end to the other. Pound in place using a hammer and wood block. Sealant Trim Strip Trim Strip Receiver Exterior Side Up Cross Section Detail 9

10 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) 9. Apply Sealant Apply sealant to ends of Trim Strip Receivers at head and sill. Fill the void at the head and sill with sealant. Apply sealant to the void at the interior side of the Installation Flange. Apply sealant between all Installation Flange overlaps. Exterior Side Up Trim Strip Caulk Gun Sealant Installation Flange (overlap) 10

11 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) 10. Apply s Double-Hung Units #8 x 5/8" Screw Failure to properly anchor using jamb clips will adversely affect design pressure rating, product performance and may result in injury, product and/ or property damage. Position s in kerf on back side of jambs, long leg to interior, extending 1-1/8" above jambs. Interior Side Up #8 x 5/8" Screw Kerf Extension Jamb (Standard) Or 6" Jamb Clip TW18 (1'-9 5/8") - TW210 Units (2'-11 5/8") Locate four s on side jambs adjacent to rough opening; 1" above Check Rail Interlock Bracket, 1" below Check Rail Interlock Bracket, 8" from bottom, and next to Gusset Plate. Locate two s on sill 8" from each side. Fasten s to sill and side jambs using two (2) #8 x 5/8" screws. (Next to Gusset Plate) 1" 1" Check Rail Interlock Bracket 8" 8" 8" (Next to Gusset Plate) 1" 1" 8" Interior View 8" 8" TW18 - TW210 Units 11

12 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) 10. Apply s (continued) TW30 (3'-1 5/8") - TW38 Units (3'-9 5/8") 8" 8" Metal fasteners and other hardware components may corrode when exposed to preservative treated and fire-retardant treated lumber. Obtain and use the appropriate metal fasteners and hardware as called out by the installation guide to fasten unit to any rough opening made from pressure treated and fire-retardant treated lumber. Failure to use the appropriate materials for the installation may cause a failure resulting in injury, property or product damage. (Next to Gusset Plate) 1" 1" Check Rail Interlock Bracket 8" 1" 1" 8" Locate four s on side jambs adjacent to rough opening; 1" above Check Rail Interlock Bracket, 1" below Check Rail Interlock Bracket, 8" from bottom, and next to Gusset Plate. Locate three s on sill 8" from each side and one at center. Fasten s to sill and side jambs using two (2) #8 x 5/8" screws. Transom Units #8 x 5/8" Screw 8" 8" TW30 - TW38 Units Interior View Failure to properly anchor using jamb clips will adversely affect design pressure rating, product performance and may result in injury, product and/ or property damage. Determine quantity of clips based on unit size from chart on Page 13. Position s in kerf on back side of jambs, long leg to interior. Locate s 6" from each corner on head and jamb. Equally space remaining clips (if required) in between. Locate s 6" from top corner on side jambs and next to Gusset Plate. Equally space the third (if required) in between. Fasten s using two 5/8" screws. (Next to Gusset Plate) 6" 6" Multiple s 6" Equally Spaced 12 Gusset Plate Interior Side Up Interior View 6" (Next to Gusset Plate)

13 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) 10. Apply s (continued) Andersen 400 Series Impact Resistant Tilt-Wash Transom Window Chart UNIT DIMENSION DIMENSION CLIPS PER CLIPS PER NAME WIDTH HEIGHT HEAD JAMB SIDE TWT /8" 12" 2 1 TWT /8" 19 5/16" 2 2 TWT /8" 21 5/16" 2 2 TWT /8" 25 5/16" 2 2 TWT /8" 27 5/16" 2 2 TWT /8" 29 5/16" 2 2 TWT /8" 335/16" 2 3 TWT /8" 39 5/16" 2 3 TWT /8" 12" 2 1 TWT /8" 19 5/16" 2 2 TWT /8" 21 5/16" 2 2 TWT /8" 25 5/16" 2 2 TWT /8" 27 5/16" 2 2 TWT /8" 29 5/16" 2 2 TWT /8" 33 5/16" 2 3 TWT /8" 39 5/16" 2 3 TWT /8" 12" 2 1 TWT /8" 19 5/16" 2 2 TWT /8" 21 5/16" 2 2 TWT /8" 25 5/16" 2 2 TWT /8" 27 5/16" 2 2 TWT /8" 29 5/16" 2 2 TWT /8" 33 5/16" 2 3 TWT /8" 39 5/16" 2 3 TWT /8" 12" 3 1 TWT /8" 19 5/16" 3 2 TWT /8" 21 5/16" 3 2 TWT /8" 25 5/16" 3 2 TWT /8" 27 5/16" 3 2 TWT /8" 29 5/16" 3 2 TWT /8" 33 5/16" 3 3 UNIT DIMENSION DIMENSION CLIPS PER CLIPS PER NAME WIDTH HEIGHT HEAD JAMB SIDE TWT /8" 39 5/16" 3 3 TWT /8" 12" 3 1 TWT /8" 19 5/16" 3 2 TWT /8" 21 5/16" 3 2 TWT /8" 25 5/16" 3 2 TWT /8" 27 5/16" 3 2 TWT /8" 29 5/16" 3 3 TWT /8" 33 5/16" 3 3 TWT /8" 39 5/16" 3 3 TWT /8" 12" 3 1 TWT /8" 19 5/16" 3 2 TWT /8" 21 5/16" 3 2 TWT /8" 25 5/16" 3 2 TWT /8" 27 5/16" 3 2 TWT /8" 29 5/16" 3 2 TWT /8" 33 5/16" 3 3 TWT /8" 39 5/16" 3 3 TWT /8" 12" 3 1 TWT /8" 19 5/16" 3 2 TWT /8" 21 5/16" 3 2 TWT /8" 25 5/16" 3 2 TWT /8" 27 5/16" 3 2 TWT /8" 29 5/16" 3 2 TWT /8" 33 5/16" 3 3 TWT /8" 39 5/16" 3 3 TWT /16" 12" 3 1 TWT /16" 12" 3 1 TWT /16" 12" 4 1 TWT /16" 12" 4 1 TWT /16" 12"

14 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) 10. Apply s (continued) Picture Window Units Failure to properly anchor using jamb clips will adversely affect design pressure rating, product performance and may result in injury, product and/ or property damage. 5/8" Screw Metal fasteners and other hardware components may corrode when exposed to preservative treated and fire-retardant treated lumber. Obtain and use the appropriate metal fasteners and hardware as called out by the installation guide to fasten unit to any rough opening made from pressure treated and fire-retardant treated lumber. Failure to use the appropriate materials for the installation may cause a failure resulting in injury, property or product damage. Gusset Plate Interior Side Up Determine quantity of clips based on unit size from chart on Page 15. Position s in kerf on back side of jambs, long leg to interior. Locate s 6" from each corner on head and jamb. Equally space remaining clips (if required) in between. Locate s 6" from top corner on side jambs and next to Gusset Plate. Equally space the third (if required) in between. Fasten s using two (2) #8 x 5/8" screws. 6" (Next to Gusset Plate) Center Multiple s Equally Spaced 6" Center Center Multiple s Equally Spaced Interior View 6" 6" 6" 6" Center 6" 14

15 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) 10. Apply s (continued) Andersen 400 Series Tilt-Wash Impact Resistant Picture Window Chart UNIT UNIT UNIT CLIPS PER CLIPS PER NAME WIDTH HEIGHT HEAD JAMB SIDE DHP " 48 14/16" 1 3 DHP " 52 14/16" 1 4 DHP " 56 14/16" 1 4 DHP " 60 14/16" 1 4 DHP " 64 14/16" 1 4 DHP " 68 14/16" 1 4 DHP " 72 14/16" 1 5 DHP " 76 14/16" 1 5 DHP /16" 4814/16" 3 3 DHP /16" 52 14/16" 3 4 DHP /16" 56 14/16" 3 4 DHP /16" 60 14/16" 3 4 DHP /16" 64 14/16" 3 4 DHP /16" 68 14/16" 3 4 DHP /16" 72 14/16" 3 5 DHP /16" 76 14/16" 3 5 DHP /16" 48 14/16" 3 3 DHP /16" 52 14/16" 3 4 DHP /16" 56 14/16" 3 4 DHP /16" 60 14/16" 3 4 DHP /16" 64 14/16" 3 4 DHP /16" 68 14/16" 3 4 DHP /16" 72 14/16" 3 5 DHP /16" 76 14/16" 3 5 DHP /16" 48 14/16" 3 3 DHP /16" 52 14/16" 3 4 DHP /16" 56 14/16" 3 4 DHP /16" 60 14/16" 3 4 UNIT UNIT UNIT CLIPS PER CLIPS PER NAME WIDTH HEIGHT HEAD JAMB SID DHP /16" 64 14/16" 3 4 DHP /16" 68 14/16" 3 4 DHP /16" 72 14/16" 3 5 DHP /16" 76 14/16" 3 5 DHP /16" 48 14/16" 3 3 DHP /16" 52 14/16" 3 4 DHP /16" 56 14/16" 3 4 DHP /16" 60 14/16" 3 4 DHP /16" 64 14/16" 3 4 DHP /16" 68 14/16" 3 4 DHP /16" 72 14/16" 3 5 DHP /16" 76 14/16" 3 5 DHP /16" 48 14/16" 4 3 DHP /16" 52 14/16" 4 4 DHP /16" 56 14/16" 4 4 DHP /16" 60 14/16" 4 4 DHP /16" 64 14/16" 4 4 DHP /16" 68 14/16" 4 4 DHP /16" 72 14/16" 4 5 DHP /16" 76 14/16" 4 5 DHP /16" 48 14/16" 4 3 DHP /16" 52 14/16" 4 4 DHP /16" 56 14/16" 4 4 DHP /16" 60 14/16" 4 4 DHP /16" 64 14/16" 4 4 DHP /16" 68 14/16" 4 4 DHP /16" 72 14/16" 4 5 DHP /16" 76 14/16"

16 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) 11. Apply s at Gusset Plates Determine number of clips per Gusset Plate from chart below. For Gusset Plates, Position Jamb Clips to the side of each sill Gusset Plate, long leg to interior, extending 1-1/8" above jambs, and fasten using two (2) #8-1-1/4" screws. For Gusset Plates, Position s in kerf at each head Gusset Plate, long leg to interior, extending 1-1/8" above jambs, and fasten using two (2) #8-15 x 5/8" screws. Gusset Plate #8 x 1-1/4" Screws Application at Interior Side Up Gusset Plate s Gusset Plate s #8 x 5/8" Screws #8 x 5/8" Screws Four Application at Two Application at Installation Clip Application at Mull Ends (clips per end) Average Adjacent Unit Dimension (A + B) 2 = 6' 1" (A + B) 2 = 5' 6" (A + B) 2 = 5' 1" (A + B) 2 = 4' 6" (A + B) 2 = 4' 1" (A + B) 2 = 3' 6" (A + B) 2 = 3' 1" (A + B) 2 = 2' 6" (A + B) 2 = 2' 1" (A + B) 2 = 1' 6" (A + B) 2 = 1' 1" C = (mullion length) 1"1" 1'6" 2'1" 2'6" 3'1" 3'6" 4'1" 4'6" 5'1" 5'6"

17 12. Install Window Unit 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) Windows and doors can be heavy. Use safe lifting techniques and a reasonable number of people with enough strength to lift, carry and install window and door products to avoid injury and/or product damage. DO NOT set window unit directly on sill plate. Elevate unit on shims at side jambs. plate may bow and interfere with window operation. Unit must be properly shimmed. Failure to do so could result in product damage. Provide a minimum clearance of 1/2" from top of brick/masonry to the bottom of any portion of sill. Failure to do so could result in product damage. Metal fasteners and other hardware components may corrode when exposed to preservative treated and fire-retardant treated lumber. Obtain and use the appropriate metal fasteners and hardware as called out by the installation guide to fasten unit to any rough opening made from pressure treated and fire-retardant treated lumber. Failure to use the appropriate materials for the installation may cause a failure resulting in injury, property or product damage. Backer Rod Sealant Brick Veneer Shims Sealant Apply 1/4" sealant bead, full perimeter, to back side of Installation Flange or around perimeter of rough opening 1/2" from edge as shown. Lift unit into rough opening. From interior, shim only at corners of sill under Side Jambs to level and center unit. For joined units, a shim must be placed under joining post(s) at the sill. For Wood Frame/Buck Construction, from the exterior, fasten one upper corner of unit using 1-3/4" roofing nails. Recheck level. Measure diagonally across unit, upper left to lower right and upper right to lower left corners. If measurements are within 1/8", unit is square. If unit is not square, adjust using shims. Measure across head, center, and sill of unit, from the exterior. Center dimensions must be within 1/8" of head and sill dimensions. Shim to straighten Side Jambs if necessary. Shim unit from interior between frame and rough opening (full depth) at Check Rail Interlock Brackets using flat, not tapered, shims to obtain an interlock gap of 1/8". 17 Check Rail Interlock Bracket Interior View Caulk Gun Exterior View Tape Measure Shim 1/8" Interior View

18 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) 12. Install Window Unit (Continued) Wood Frame/Buck Construction Fasten unit to wood frame rough opening using two (2) #8 x 1-1/4" screws through each. Secure Outer Frame Member Brackets to rough opening using #8 x 3" Color Matched Screws. #8 x 1-1/4" Screw Masonry Construction Fasten unit to masonry rough opening using two (2) #8 x 1-1/4" (minimum) masonry anchors through each. Remove existing 3" Color Matched Screw and secure Outer Frame Member Bracket to rough opening using #8 x 3" (minimum) masonry anchor. Interior View Outer Frame Member Bracket #8 x 3" Color Matched Screw Exterior View (bent into position) Outer Frame Member Bracket #8 x 3" Color Matched Screw (provided) Outer Frame Member Bracket Outer Frame Member Bracket #8 x 3" Minimum Masonry Screw (by others) 18

19 13. Apply Full Width Drip Cap Apply sealant at top only. Quickly place drip cap (full width) in sealant, centering over unit(s). 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) Drip Cap (full width) Caulk Gun Exterior View 14. Apply Flashing Tape This instruction step depicts one of many options for proper flashing. Moisture infiltration problems in any type of building can be reduced by properly flashing and/or sealing around all building openings, including windows and doors. Proper flashing under and around window and door openings can reduce moisture problems, but the performance of any building system depends upon the design and construction of the building system in its entirety, which should address local environment, climate, building codes and product and material limitations. The design and installation of flashing and sealing systems are the responsibility of the architect, contractor, installer, and/or the manufacturer of the building exterior specified for the project. Apply flashing tape over Installation Flange at sill. Apply flashing tape over Installation Flange at sides, overlapping flashing tape at sill. Apply flashing tape over Installation Flange at head, overlapping flashing tape at sides. Flashing Tape (apply third) Sides (apply second) Exterior View (apply first) 19

20 15. Seal Sides Apply sealant to sides where installation flange meets sides of units. 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) Caulk Gun Exterior View 16. Insulate and Seal Unit When insulating between unit's frame and rough opening or between units when joining, DO NOT overpack batt insulation or overfill with foam. Bowed jambs will result affecting product performance and/ or proper operation of unit. Backer Rod Sealant Backer Rod Sealant A minimum space of 1/4" is required around exterior perimeter of unit between frame and siding. Masonry/Brick Veneer installations require a minimum 1/2" space along sill and 1/4" space around the remaining perimeter. Cross Section Detail - Cross Section Detail - Side Jamb Insulate between frame, extension jambs, and rough opening on all sides from the interior. DO NOT overpack or overfill with insulation, bowed jambs may result. Apply backer rod and sealant around exterior perimeter of window after siding (or other finish) is applied. Caulk Gun Siding Brick Veneer Exterior View 20

21 17. Apply Extension Jambs Ripping of Extension Jambs may be required to fit nonstandard wall depths. Contact your Andersen dealer for further information. Drill 3/32" holes, 12"-18" apart, through each Extension Jamb on back side of kerf if Extension Jamb is not already pre-drilled. Start #8 x 1-1/4" drywall screws in holes. Position, and Side Extension Jambs on frame. Fasten center screw into each Extension Jamb using a power drill with Phillips extension. Square,, and Side Extension Jambs to unit. Fasten screws in Extension Jambs. Shim between Extension Jambs and rough opening. Face nail Extension Jambs to rough opening at shims. 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) Extension Jam Side Extension Jamb #8 x 1-1/4" Screw Center Screw Extension Jamb Interior Views #8 x 1-1/2" Corner Screw Interior Views 21

22 Finishing, Cleaning, and Maintenance Instructions 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) DO NOT expose unfinished wood to high moisture conditions, excessive heat or humidity. Finish interior wood surfaces immediately after installation. Unfinished wood surfaces will discolor, deteriorate, and/or may bow and split. DO NOT stain or paint weatherstrip, silicone beads, vinyl, glass, or hardware. Damage to product may occur and unit operation may be impaired. Acid solutions used to wash masonry/concrete will damage glass, fasteners, hardware, and metal flashing. If these solutions are used, follow the acid solution manufacturer's instructions carefully. Protect and/or cover Andersen products during the cleaning process to prevent acid contact. If acid does come in contact with unit, immediately wash all surfaces with clean water. INTERIOR FINISHING Read and follow finishing manufacturer s instructions and warnings on each container of finish material for priming, painting, staining, and varnishing. CLEANING Clean exterior frame, sash members, and insect screens using a mild detergent-and-water solution and a soft cloth or brush. DO NOT use abrasive cleaners or solutions containing corrosive solvents. For persistent dirt or grime, use a nonabrasive cleanser or a mixture of water and alcohol or ammonia. MAINTENANCE Immediately sand and refinish any interior wood that becomes stained or mildewed to prevent further discoloration and/or damage. For further information, contact your local Andersen dealer. Dealers can be found in the Yellow Pages under Windows. 22

23 3/4" LVL Reinforced Joining Guide (1-Way Horizontal Joining) 3/4" LVL Reinforced Joining Guide (1-Way Horizontal Joining) for Andersen 400 Series Tilt-Wash Transom or Narroline Circle Top Window over 400 Series Tilt-Wash Double-Hung or Tilt-Wash Picture Windows with Stormwatch Protection Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance are essential if the benefits of your Andersen product are to be fully attained. Therefore, please read and follow this Instruction Guide completely. If your abilities do not match this procedure s requirements, contact an experienced contractor. You may direct any questions about this or other products to your local Andersen dealer, found in the Yellow Pages under Windows or call Andersen WindowCare service center at Monday through Friday, 7 a.m. to 7 p.m. Central Time and Saturday, 8 a.m. to 4 p.m. Central Time. Thank you for choosing Andersen. Impact Resistant Glass used by Andersen is not hurricane proof or shatter proof, and may not offer a high level of security. Proper installation of window and door units with impact resistant glass is as important to product performance as the glass. Every assembly and installation is different (windloads, structural support, etc.), and Andersen strongly recommends consultation with an Andersen supplier or an experienced contractor, architect, or structural engineer prior to the assembly and installation of any Andersen product. Andersen has no responsibility in regard to the post-manufactured assembly and installation of Andersen products. Use caution when working at elevated heights and around unit openings. Follow manufacturer s instructions for safe use of ladder and/or scaffolding. Failure to do so may result in injury or death. Follow manufacturer s instructions for safe operation of hand/power tools. Always wear safety glasses. Failure to do so may result in injury and/ or product damage. Windows and doors can be heavy. Use safe lifting techniques and a reasonable number of people with enough strength to lift, carry and install window and door products to avoid injury and/or product damage. Unless specifically ordered, Andersen windows and doors are not equipped with safety glass, and if broken, could fragment causing injury. Many laws and building codes require safety glass in locations adjacent to or near doors. Andersen windows are available with safety glass that may reduce the likelihood of injury when broken. Information on safety glass is available from your local Andersen dealer. Andersen Flashing and Installation Flanges DO NOT take the place of standard window and door flashing. Unit must be properly flashed and sealed with silicone for protection against water and air infiltration. Use non-reflective flashings. Highly reflective flashing tapes can raise the surface temperature of the vinyl to the point where vinyl deformation and product damage may occur. Do not apply any type of film to glass. Thermal stress conditions resulting in glass damage could occur. Use of movable insulating materials such as window coverings, shutters, and other shading devices may damage glass and/or vinyl. In addition, excessive condensation may result causing deterioration of windows and doors. Andersen and all other marks where denoted are trademarks of Andersen Corporation Andersen Corporation. All rights reserved. 23 Revised 11/24/08

24 3/4" LVL Reinforced Joining Guide (1-Way Horizontal Joining) Metal fasteners and other hardware components may corrode when exposed to preservative treated and fireretardant treated lumber. Obtain and use the appropriate metal fasteners and hardware as called out by the installation guide to fasten unit to any rough opening made from pressure treated and fire-retardant treated lumber. Failure to use the appropriate materials for the installation may cause a failure resulting in injury, property or product damage. Units must be installed according to the following installation instructions using s or product will not meet designated performance levels. DO NOT apply Extension Jambs prior to unit installation. Use this guide to join two units horizontally. Exterior Views Parts Included (1) Instruction Guide (2) Gusset Plates (1) 3/4" LVL Joining Strip (1) Exterior Trim Strip (1) Installation Screw Pack (2) Gusset Plates (for Narroline Circle Top Windows) (1) Filler Piece (for Narroline Circle Top Windows) Component Identification Gusset Plate (for Narroline Circle Top Windows) Tools and Supplies Safety Glasses Tape Measure Pencil Level Hammer Clamps Power Drill Caulk Gun Sealant Vise Grip/Pliers Screw Driver Utility Knife Small Pry Bar 3/8" Wood Shims Power Saw File/Rasp Putty Knife 3/32" Drill Bit Isopropyl Alcohol Wood Blocks Shims 7/16" x 1/2" x 16 Gauge Staples Pneumatic Stapler 1-3/4" Roofing Nails 3/4" LVL Joining Strip Gusset Plate Filler Piece (for Narroline Circle Top Windows) Additional Parts Required Drip Cap (full width) Exterior Trim Strip 24

25 1. Verify that LVL Joining is Adequate for Your Installation Calculate the average adjacent unit dimension ((A + B) 2). Determine the mullion length (C). Use the windload table below to cross reference the average adjacent unit dimension with the mullion length to determine the windload performance of your combination. Be sure that this performance is adequate for your installation requirements. Refer to the Combination Design section in the Andersen Product Guide for Professionals for further information. 3/4" LVL Reinforced Joining Guide (1-Way Horizontal Joining) Transom Unit Double-Hung Unit Exterior View Design Windload PSF Table for 3/4" LVL Reinforced Joining Type of Combination: Horizontal Joining For Combining: 400 Series Double-Hung Transom Window over 400 Series Tilt-Wash Double-Hung or Picture Windows Average Adjacent Unit Dimension (A + B) 2 = 6' 1" (A + B) 2 = 5' 6" (A + B) 2 = 5' 1" (A + B) 2 = 4' 6" (A + B) 2 = 4' 1" (A + B) 2 = 3' 6" PSF (A + B) 2 = 3' 1" (A + B) 2 = 2' 6" (A + B) 2 = 2' 1" (A + B) 2 = 1' 6" (A + B) 2 = 1' 1" C = (mullion length) 1"1" 1'6" 2'1" 2'6" 3'1" 3'6" 4'1" 4'6" 5'1" 5'6" 6'1" 25

26 2. Prepare Rough Opening 3/4" LVL Reinforced Joining Guide (1-Way Horizontal Joining) The use of building wrap and/or flashing materials will reduce the rough opening size. Adjust as necessary. Determine rough opening height for multiple units using the formula: rough opening height = 3/8" (shim) + total unit heights + 3/4" for each join (LVL Joining Strip) + 3/8" (shim). Determine rough opening width using the formula: rough opening width = 3/8" (shim) + unit width + 3/8" (shim). Check rough opening for plumb and level. If rough opening is not plumb or level, correct as necessary. Check opening for square by measuring diagonally, upper left to lower right and upper right to lower left corner. If measurements are within 1/8", opening is square. If rough opening is not square, correct as necessary. Tape Measure Level Exterior View 3. Prepare Units Place units interior side up on a clean, flat work surface. Remove Installation Flange(s) on head jamb of Double-Hung Unit and sill of Transom / Circle Top Unit. Remove banding tape on Double-Hung Window. Double-Hung Unit 3/4" LVL Joining Strip Gusset Plate Transom Unit Interior Side Up Jamb (Double-Hung Unit) (Transom Unit) Transom Unit Installation Flanges (Removed) Double-Hung Unit Interior Side Up Exterior View 26

27 3. Prepare Units (Continued) For Double-Hung Units, remove the end of head jamb tenon joints that protrudes into the side jamb kerf, using a small file or rasp. Remove enough material so Gusset Plate will lie flat in kerf. For Picture Window Units, remove the end of head jamb tenon joint that protrudes into the side jamb kerf, using a small file or rasp. Remove enough material so Gusset Plate will lie flat in kerf. For Transom Window Units, remove the end of sill jamb tenon joint that protrudes into the side jamb kerf, using a small file or rasp. Remove enough material so Gusset Plate will lie flat in kerf. For Narroline Circle Top, position Filler Piece flush with Interior Frame. Attach using 3/4" fasteners every 8" 4. Prepare 3/4" LVL Joining Strip Square end cut 3/4" LVL Joining Strip 1/2" shorter than width of units to be joined. Remove 1-1/2" of aluminum leg from each side at ends of 3/4" LVL Joining Strip using a vise grip/pliers. Side Jamb Kerf 3/4" LVL Reinforced Joining Guide (1-Way Horizontal Joining) Double-Hung Unit Tenon Joint Filler Piece 3/4" LVL Joining Strip Aluminum Leg Transom Unit Side Jamb Kerf Tenon Joint Interior Side Up Narroline Circle-Top Unit Vise Grip/ Pliers 1-1/2" 5. Attach 3/4" LVL Joining Strip Place locator tab of 3/4" LVL Joining Strip into kerf on head jamb and center on unit. 3/4" LVL Joining Strip must not extend into side jamb kerfs. Fasten using three (3) #8 x 1-3/8" screws, equally spaced. Interior Side Up Side Jamb Kerf Kerf #8 x 1-3/8" Screw Locator Tab 3/4" LVL Joining Strip 27

28 6. Join Units Transom / Circle Top over Tilt-Wash 3/4" LVL Reinforced Joining Guide (1-Way Horizontal Joining) 3/4" LVL Joining Strip Clamp Exterior nose of units and side jambs must be flush full length. Failure to do so will prevent proper sealing causing water infiltration. Excess tightening of clamps may mar surface. Upper unit side jamb Installation Flange must overlap lower unit side Installation Flange to the exterior. Slide units together, overlapping upper unit Installation Flange over lower unit Installation Flange to the exterior. Exterior nose of units and side jambs must be flush full length. Clamp units together, from the interior, using two clamps with surface protectors/wood blocks. Slide upper and lower sash down in Tilt-Wash Unit frame so Jamb Liner is accessible and brace with a wood block. Remove Jamb Liner screws on Tilt-Wash unit if present. Drill 3/32" holes through existing holes no deeper than 2-1/2". If Jamb Liner Screws are not present, use a 3/32" drill bit to drill pilot holes on Jamb Liner scribe line 4" from each end and equally spaced between as shown. See table below for total quantity of holes required. Unit Width TW38 & TW34 4 All Others 3 Total Holes Required 4" Installation Flange (Lower Unit) 3 or 4 Holes Equally Spaced Jamb Liner 4" Installation Flange (Upper Unit) Jamb Liner Screw (Remove if Present) Wood Block Interior Side Up Fasten units together through lower unit Jamb using #10 x 2-1/2" screws. Drill 4" Pilot Hole Scribe Line #10 x 2-1/2" Screws (Through Pilot Holes in Jamb Liner) Interior Side Up 28

29 3/4" LVL Reinforced Joining Guide (1-Way Horizontal Joining) 6. Join Units (Continued) Transom / Circle Top over Picture Window Exterior nose of units and side jambs must be flush full width. Failure to do so will prevent proper sealing causing water infiltration. Excess tightening of clamps may mar surface. Upper unit Installation Flange must overlap lower unit Installation Flange to the exterior. Installation Flange (Lower Unit) Interior Side Up Slide units together, overlapping upper unit Installation Flange over lower unit Installation Flange to the exterior. Exterior nose of units and side jambs must be flush full width. Insert a small pry bar between Side Jamb Liner and Interior Trim Stop, approximately 2" down from head jamb. Pry Side Jamb Liner toward exterior and insert a thin blade putty knife at bottom of Side Jamb Liner next to sill. Pry Side Jamb Liner toward the exterior and remove. Repeat procedure for opposite Side Jamb Liner. Insert a putty knife between Jamb Liner and Interior Glass Stop. Twist blade of putty knife until can be grasped and removed. Side Jamb Liner Small Pry Bar Installation Flange (Upper Unit) Putty Knife Picture Window Unit Interior Side Up Jamb Liner Putty Knife Interior Glass Stop Picture Window Unit Interior Side Up 29

30 3/4" LVL Reinforced Joining Guide (1-Way Horizontal Joining) 6. Join Units (Continued) Transom/Circle Top over Picture Window (Continued) Clamp units together, from the interior, using two clamps and surface protectors. Clamp DO NOT drill holes deeper than 2-1/2". Drilling deeper than 2-1/2" will result in a hole through the Transom Glass Stop. Clamp units together, from the interior, using two clamps and surface protectors. Drill three holes through head jamb of Double-Hung Picture Unit in the middle of void exposed when Jamb Liner was removed. Holes should be located 4" from each side jamb and on center, midway between the side jambs. Drill through the head jamb of the unit, through 3/4" LVL Joining Strip, and into the jamb of the Transom/Circle Top Unit using a 3/32" drill bit. DO NOT drill deeper than 2-1/2". DO NOT drive screw heads deeper than flush with head jamb. Driving screws deeper than surface of head jamb may result in damage to Transom Glass Stop #10 x 2-1/2" Screw (4" from side jambs) Jamb (Picture Unit) 2-1/2" Screw Interior Side Up 3/4" LVL Joining Strip Interior Exterior Fasten units using #10 x 2-1/2" screws through drilled holes in the Double-Hung Picture Unit head jamb. DO NOT drive/insert screws further than flush with the head jamb. Reinstall Jamb Liner by inserting long leg of liner into head pocket, pushing up on short leg to snap into place. Insert interior leg of Side Jamb Liner behind Interior Trim Stop, pushing in on exterior leg to snap into place. Repeat for opposite side. Cross Section Detail Jamb Liner Long Leg Picture Window Unit Interior Side Up 30

31 7. Attach Gusset Plates Position Gusset Plate in jamb kerf centered over unit join and fasten using # 8 x 5/8" Screws. 3/4" LVL Reinforced Joining Guide (1-Way Horizontal Joining) Gusset Plate Jamb Kerf Interior Side Up #8 x 5/8" Screws Narroline Circle Top over Tilt-Wash or Picture Window Place Gusset Plates on side jambs 3/4" down from interior edge and in center of joint. Secure with two rows of 1/2" staples. Gusset Plate Narroline Circle Top Interior Side Up 1/2" Staples 31

32 8. Apply Exterior Trim Strip Turn unit assembly exterior side up. Clean surface of Trim Strip Receiver and vinyl surface of unit for proper adhesion using isopropyl alcohol. Apply a continuous 1/8" bead of sealant along joins of Trim Strip Receivers and jambs. 3/4" LVL Reinforced Joining Guide (1-Way Horizontal Joining) Trim Strip Receiver Initial positioning of Exterior Trim Strip is important because it is very difficult to remove once inserted. Position edge of Exterior Trim Strip flush with unit edge and press in with thumbs from one end to the other. Pound in place using a hammer and wood block. Apply sealant to voids at both ends of Exterior Trim Strip. Completely fill void between units on exterior side of Installation Flange. Turn unit assembly interior side up. Apply sealant to void between units on interior side of Installation Flange for 1/2" on both sides. Exterior Trim Strip Sealant Sealant Caulk Gun Exterior Side Up Caulk Gun Apply sealant behind Installation Flange for 1/2 on both sides. 32

33 9. Apply s Double-Hung Units 3/4" LVL Reinforced Joining Guide (1-Way Horizontal Joining) Failure to properly anchor using jamb clips will adversely affect design pressure rating, product performance and may result in injury, product and/ or property damage. Position s in kerf on back side of jambs, long leg to interior, extending 1-1/8" above jambs, as shown. Interior Side Up #8 x 5/8" Screw Kerf Extension Jamb (Standard) Or 6" Jamb Clip TW18 (1'-9 5/8") - TW210 Units (2'-11 5/8") Locate four s on side jambs; 1" above Check Rail Interlock Bracket, 1" below Check Rail Interlock Bracket, 8" from bottom, and next to Gusset Plate. Locate two s on sill 8" from each side. Fasten s to sill and side jambs using two (2) #8 x 5/8" screws. (Next to Gusset Plate) 1" Check Rail Interlock Bracket 1" 8" 1" 1" 8" Transom Unit (s Applied on Page 12) (Next to Gusset Plate) 8" 8" TW18 - TW210 Units Interior View 33

34 3/4" LVL Reinforced Joining Guide (1-Way Horizontal Joining) 9. Apply s (continued) TW30 (3'-1 5/8") - TW38 Units (3'-9 5/8") Locate four s on side jambs; 1" above Check Rail Interlock Bracket, 1" below Check Rail Interlock Bracket, 8" from bottom, and next to Gusset Plate. Locate three s on sill 8" from each side and one at center. Fasten s to sill and side jambs using two (2) #8 x 5/8" screws. (Next to Gusset Plate) 1" 1" Check Rail Interlock Bracket 8" Transom Unit (s Applied on Page 12) 1" 1" 8" 8" 8" TW30 - TW38 Units Interior View Picture Window Units #8 x 5/8" Screw Failure to properly anchor using jamb clips will adversely affect design pressure rating, product performance and may result in injury, product and/ or property damage. Interior Side Up Determine quantity of s based on unit size from chart on Page 35. Position s in kerf on back side of jambs, long leg to interior. Locate s 6" from each corner on head and jamb. Equally space remaining clips (if required) in between. Locate s 6" from top corner on side jambs and next to Gusset Plate. Equally space the additional (if required) in between. Fasten s using two (2) #8 x 5/8" screws. 6" Equal Equal Transom Unit (s Applied on Page 12) 6" Equal Equal (Next to Gusset Plate) Equal Equal 6" 6" 6" Equal Equal 6" Interior View 34

35 3/4" LVL Reinforced Joining Guide (1-Way Horizontal Joining) 9. Apply s (continued) Andersen 400 Series Tilt-Wash Double-Hung Picture Window Chart UNIT UNIT UNIT CLIPS PER CLIPS PER NAME WIDTH HEIGHT HEAD JAMB SIDE DHP " 48 14/16" 1 3 DHP " 52 14/16" 1 4 DHP " 56 14/16" 1 4 DHP " 60 14/16" 1 4 DHP " 64 14/16" 1 4 DHP " 68 14/16" 1 4 DHP " 72 14/16" 1 5 DHP " 76 14/16" 1 5 DHP /16" 4814/16" 3 3 DHP /16" 52 14/16" 3 4 DHP /16" 56 14/16" 3 4 DHP /16" 60 14/16" 3 4 DHP /16" 64 14/16" 3 4 DHP /16" 68 14/16" 3 4 DHP /16" 72 14/16" 3 5 DHP /16" 76 14/16" 3 5 DHP /16" 48 14/16" 3 3 DHP /16" 52 14/16" 3 4 DHP /16" 56 14/16" 3 4 DHP /16" 60 14/16" 3 4 DHP /16" 64 14/16" 3 4 DHP /16" 68 14/16" 3 4 DHP /16" 72 14/16" 3 5 DHP /16" 76 14/16" 3 5 DHP /16" 48 14/16" 3 3 DHP /16" 52 14/16" 3 4 DHP /16" 56 14/16" 3 4 DHP /16" 60 14/16" 3 4 UNIT UNIT UNIT CLIPS PER CLIPS PER NAME WIDTH HEIGHT HEAD JAMB SIDE DHP /16" 64 14/16" 3 4 DHP /16" 68 14/16" 3 4 DHP /16" 72 14/16" 3 5 DHP /16" 76 14/16" 3 5 DHP /16" 48 14/16" 3 3 DHP /16" 52 14/16" 3 4 DHP /16" 56 14/16" 3 4 DHP /16" 60 14/16" 3 4 DHP /16" 64 14/16" 3 4 DHP /16" 68 14/16" 3 4 DHP /16" 72 14/16" 3 5 DHP /16" 76 14/16" 3 5 DHP /16" 48 14/16" 4 3 DHP /16" 52 14/16" 4 4 DHP /16" 56 14/16" 4 4 DHP /16" 60 14/16" 4 4 DHP /16" 64 14/16" 4 4 DHP /16" 68 14/16" 4 4 DHP /16" 72 14/16" 4 5 DHP /16" 76 14/16" 4 5 DHP /16" 48 14/16" 4 3 DHP /16" 52 14/16" 4 4 DHP /16" 56 14/16" 4 4 DHP /16" 60 14/16" 4 4 DHP /16" 64 14/16" 4 4 DHP /16" 68 14/16" 4 4 DHP /16" 72 14/16" 4 5 DHP /16" 76 14/16"

36 3/4" LVL Reinforced Joining Guide (1-Way Horizontal Joining) 9. Apply s (continued) Transom Units Failure to properly anchor using jamb clips will adversely affect design pressure rating, product performance and may result in injury, product and/ or property damage. Determine quantity of s based on unit size from chart on Page 37. Position s in kerf on back side of jambs, long leg to interior. Locate s 6" from each corner on head and jamb. Equally space remaining clips (if required) in between. Locate s 6" from top corner on side jambs and next to Gusset Plate. Equally space the additional (if required) in between. Fasten s using two (2) #8 x 5/8" screws. 6" Multiple Clips Equally Spaced 5/8" Screw 6" Interior Side Up 6" 6" 6" 6" Transom Unit Double-Hung Unit Interior View 36

Installation Guide. for Andersen 400 Series Tilt-Wash Picture Windows with Stormwatch Protection (High-Performance Impact Resistant Glass)

Installation Guide. for Andersen 400 Series Tilt-Wash Picture Windows with Stormwatch Protection (High-Performance Impact Resistant Glass) for Andersen 400 Series Tilt-Wash Picture Windows with Stormwatch Protection (High-Performance Impact Resistant Glass) Installation Guide Congratulations! You have just purchased one of the many fine Andersen

More information

Installation Guide for Andersen 200 Series Tilt-Wash Picture, Transom and Circle Top Windows

Installation Guide for Andersen 200 Series Tilt-Wash Picture, Transom and Circle Top Windows for Andersen 200 Series Tilt-Wash Picture, Transom and Circle Top Windows Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance

More information

3/4" LVL Reinforced Joining Guide

3/4 LVL Reinforced Joining Guide (2-Way Horizontal and Vertical Joining) for Andersen 400 Series Tilt-Wash Double-Hung, Picture, and Transom Windows with Stormwatch Protection Congratulations! You have just purchased one of the many fine

More information

Installation Guide for Andersen 400 Series Tilt-Wash Transom and 200 Series Narroline Transom Windows

Installation Guide for Andersen 400 Series Tilt-Wash Transom and 200 Series Narroline Transom Windows for Andersen 400 Series Tilt-Wash Transom and 200 Series Narroline Transom Windows Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance

More information

Installation Guide for Andersen 400 Series Tilt-Wash Transom Windows with Stormwatch Protection (PG Upgrade) Manufactured After 2006

Installation Guide for Andersen 400 Series Tilt-Wash Transom Windows with Stormwatch Protection (PG Upgrade) Manufactured After 2006 for Andersen 400 Series Tilt-Wash Transom Windows with Stormwatch Protection (PG Upgrade) Manufactured After 2006 Thank you for choosing Andersen. Instructions are for typical, new wood-framed wall construction

More information

Installation Guide for Architectural Wood Hinged Windows

Installation Guide for Architectural Wood Hinged Windows Guide for Architectural Wood Hinged Windows Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance are essential if the benefits

More information

Installation Guide for Andersen Frenchwood Patio Door Sidelights and Transoms

Installation Guide for Andersen Frenchwood Patio Door Sidelights and Transoms for Andersen Frenchwood Patio Door Sidelights and Transoms Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance are essential if

More information

Panel Assembly and Installation

Panel Assembly and Installation Assembly and Installation Assembly and Installation for Andersen 400 Series Frenchwood, 200 Series Narroline, 200 Series Perma-Shield Gliding Patio Doors and 400 Series Perma-Shield Gliding Patio Doors

More information

Non-Reinforced Joining Guide (2-Way Horizontal and Vertical Joining) for Andersen 200 Series Tilt-Wash Double-Hung and Transom Windows

Non-Reinforced Joining Guide (2-Way Horizontal and Vertical Joining) for Andersen 200 Series Tilt-Wash Double-Hung and Transom Windows (2-Way Horizontal and Vertical Joining) for Andersen 200 Series Tilt-Wash Double-Hung and Transom Windows Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly,

More information

Sash Replacement Guide for Andersen 400 Series Tilt-Wash Transom Windows

Sash Replacement Guide for Andersen 400 Series Tilt-Wash Transom Windows for Andersen 400 Series Tilt-Wash Transom Windows Read all instructions carefully before attempting this procedure. If you have any questions about your ability to complete this procedure, call Andersen

More information

Installation Guide for Andersen 400 Series Gliding Windows

Installation Guide for Andersen 400 Series Gliding Windows for Andersen 400 Series Gliding Windows Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance are essential if the benefits of your

More information

Non-Reinforced Joining Guide (1-Way Vertical or Horizontal) for Andersen 200 Series Tilt-Wash Double-Hung Windows and Complementary Products

Non-Reinforced Joining Guide (1-Way Vertical or Horizontal) for Andersen 200 Series Tilt-Wash Double-Hung Windows and Complementary Products (1-Way Vertical or Horizontal) for Andersen 200 Series Tilt-Wash Double-Hung Windows and Complementary Products Non-Reinforced Joining Guide Congratulations! You have just purchased one of the many fine

More information

Installation Guide for Andersen Architectural Clad Awning Windows

Installation Guide for Andersen Architectural Clad Awning Windows Guide for Andersen Architectural Clad Awning Windows Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance are essential if the

More information

Steel Reinforced Joining Guide (Horizontal / Vertical)

Steel Reinforced Joining Guide (Horizontal / Vertical) (Horizontal / Vertical) for Andersen Patio Door and/or Elliptical Top Window Combinations Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation

More information

for Andersen 400 Series Woodwright Transom over 400 Series Woodwright Double-Hung or 400 Series Woodwright Picture Window

for Andersen 400 Series Woodwright Transom over 400 Series Woodwright Double-Hung or 400 Series Woodwright Picture Window for Andersen 400 Series Woodwright Transom over 400 Series Woodwright Double-Hung or 400 Series Woodwright Picture Window Congratulations! You have just purchased one of the many fine Andersen products.

More information

Non-Reinforced Joining Guide (Horizontal/Vertical)

Non-Reinforced Joining Guide (Horizontal/Vertical) Non-Reinforced Joining Guide (Horizontal/Vertical) for Andersen Casement, Awning, and Picture Windows Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation

More information

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows americancraftsmanwindows.com Project Requirements: Read

More information

Installation Guide for Andersen Architectural Clad Inswing Entry and Patio Doors

Installation Guide for Andersen Architectural Clad Inswing Entry and Patio Doors Installation Guide for Andersen Architectural Clad Inswing Entry and Patio Doors Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance

More information

Installation Guide for Andersen Architectural Clad Hinged Windows

Installation Guide for Andersen Architectural Clad Hinged Windows Guide for Andersen Architectural Clad Hinged Windows Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance are essential if the

More information

Steel Reinforced Joining Thank you for choosing Andersen. Please leave this guide with building owner.

Steel Reinforced Joining Thank you for choosing Andersen. Please leave this guide with building owner. Steel Reinforced Joining (Horizontal/Vertical) for Andersen 400 Series Woodwright & Tilt-Wash Double-Hung, Picture, and Transom Windows and 400 Series Double-Hung Half Circle and Flexiframe Specialty Windows

More information

for Andersen Frenchwood Hinged and Outswing Patio Doors, Sidelights, and Transoms

for Andersen Frenchwood Hinged and Outswing Patio Doors, Sidelights, and Transoms for Andersen Frenchwood Hinged and Outswing Patio Doors, Sidelights, and Transoms Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance

More information

Fixed Upper Sash Replacement Guide for Andersen 400 Series Woodwright Springline Single-Hung Windows

Fixed Upper Sash Replacement Guide for Andersen 400 Series Woodwright Springline Single-Hung Windows Fixed Upper Sash Replacement Guide for Andersen 400 Series Woodwright Springline Single-Hung Windows Manufactured Between September 2005 and October 2006 Read all instructions carefully before attempting

More information

Sash Replacement Guide for Andersen Impact Resistant Casement Windows

Sash Replacement Guide for Andersen Impact Resistant Casement Windows Replacement Guide Replacement Guide for Andersen Impact Resistant Casement Windows Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance

More information

WOOD OUT SWING AWNING, CASEMENT, & HOPPER WINDOW

WOOD OUT SWING AWNING, CASEMENT, & HOPPER WINDOW WOOD OUT SWING AWNING, CASEMENT, & HOPPER WINDOW INSTALLATION GUIDE READ SPECIFIC INSTALLATION INSTRUCTIONS COMPLETELY BEFORE STARTING ANY INSTALLATION Failure to install and maintain our product according

More information

Read guide from beginning to end before starting installation. Read and follow all warnings and cautions during unit installation.

Read guide from beginning to end before starting installation. Read and follow all warnings and cautions during unit installation. Installation Guide for Andersen Clad Outswing Folding Doors with Track-In-Floor Thank you for choosing Andersen. Instructions are for typical, new wood-framed wall construction with weather protection

More information

Installation Instructions for E-Series 2 or 4-Panel Gliding and French Gliding Patio Doors

Installation Instructions for E-Series 2 or 4-Panel Gliding and French Gliding Patio Doors Installation Instructions for E-Series 2 or 4-Panel Gliding and French Gliding Patio Doors Thank you for choosing Andersen. Instructions are for typical, new wood-framed wall construction with weather

More information

Read guide from beginning to end before starting installation. Read and follow all warnings and cautions during unit installation.

Read guide from beginning to end before starting installation. Read and follow all warnings and cautions during unit installation. Installation Guide for Andersen Wood Outswing Folding Doors with Track-In-Floor Thank you for choosing Andersen. Instructions are for typical, new wood-framed wall construction with weather protection

More information

INSTALLATION GUIDE WOOD PIVOTING CIRCLE/ OVAL

INSTALLATION GUIDE WOOD PIVOTING CIRCLE/ OVAL WOOD PIVOTING CIRCLE/ OVAL READ SPECIFIC INSTALLATION INSTRUCTIONS COMPLETELY BEFORE STARTING ANY INSTALLATION Failure to install and maintain our product according to these instructions will VOID any

More information

Assembled Patio Door Installation Guide 2-Panel Patio Door with Non-Welded Frame

Assembled Patio Door Installation Guide 2-Panel Patio Door with Non-Welded Frame Assembled Patio Door Installation Guide 2-Panel Patio Door with Non-Welded Frame americancraftsmanwindows.com American Craftsman and all other marks where denoted are trademarks of Andersen Corporation

More information

Transom Joining. for Andersen Elliptical Windows over Perma-Shield Gliding Patio Door

Transom Joining. for Andersen Elliptical Windows over Perma-Shield Gliding Patio Door Transom Joining for Andersen Elliptical Windows over Perma-Shield Gliding Patio Door INSTALLER: Please leave this guide with the building owner to file for future reference. Congratulations! You have just

More information

Follow instructions from foam, sealant and flashing manufacturer regarding material application and compatibility with this product.

Follow instructions from foam, sealant and flashing manufacturer regarding material application and compatibility with this product. Installation Guide for Andersen Wood Outswing Folding Doors Thank you for choosing Andersen. Instructions are for typical, new wood-framed wall construction with weather protection in place. Instructions

More information

Installation Guide for E-Series/Eagle Ascent 2 or 4 Panel Gliding (Sliding) Patio Doors

Installation Guide for E-Series/Eagle Ascent 2 or 4 Panel Gliding (Sliding) Patio Doors Installation Guide for E-Series/Eagle Ascent 2 or 4 Panel Gliding (Sliding) Patio Doors Thank you for choosing Andersen. Instructions are for typical, new wood-framed wall construction with weather protection

More information

Reinforced 10 Bow Window Assembly and Installation Guide for Andersen 400 Series Transom Joined Casement Windows

Reinforced 10 Bow Window Assembly and Installation Guide for Andersen 400 Series Transom Joined Casement Windows Reinforced 10 Bow Window Assembly and Installation Guide for Andersen 400 Series Transom Joined Casement Windows Thank you for choosing Andersen. Instructions are for typical, new wood-framed wall construction

More information

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation. Installation Guide for E-Series/Eagle High-Performance Mullion Windows with LVL Reinforcement and Installed Using Type B Clips Thank you for choosing Andersen. Instructions are for typical, new wood-framed

More information

Stationary Panel Replacement

Stationary Panel Replacement Stationary Panel Replacement Product Series: 200 Series Product Type: Hinged Inswing Patio Doors Read these instructions before starting procedure. For additional information visit www.andersenwindows.com.

More information

Installation Guide for E-Series/Eagle Clad Mechanically Fastened Windows

Installation Guide for E-Series/Eagle Clad Mechanically Fastened Windows Guide for E-Series/Eagle Clad Mechanically Fastened Windows Thank you for choosing Andersen. Instructions are for typical, new wood-framed wall construction with weather protection in place. Instructions

More information

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS 2008 Pella Corporation Part Number: 803V0101 INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS Installation Instructions for Typical Wood Frame Construction. These instructions were developed

More information

Installation Guide. for E-Series/Eagle Clad Hinged Inswing French Door

Installation Guide. for E-Series/Eagle Clad Hinged Inswing French Door Installation Guide for E-Series/Eagle Clad Hinged Inswing French Door Thank you for choosing Andersen. Instructions are for typical, new wood-framed wall construction with weather protection in place.

More information

Installation Guidelines for all Quaker products with nail fins New Construction nail fin installation with a Zip sheathing system.

Installation Guidelines for all Quaker products with nail fins New Construction nail fin installation with a Zip sheathing system. www.quakerwindows.com www.quakercommercialwindows.com PO Box 128 504 Highway 63 South Freeburg, MO 65035 800-347-0438 573-469-4151 (fax) Installation Guidelines for all Quaker products with nail fins New

More information

Installation Guidelines. Next Dimension. Single Hung / Single Hung Fixed / Double Hung / Sliding Window / Fixed Window

Installation Guidelines. Next Dimension. Single Hung / Single Hung Fixed / Double Hung / Sliding Window / Fixed Window Installation Guidelines Next Dimension Single Hung / Single Hung Fixed / Double Hung / Sliding Window / Fixed Window Windsor Windows & Doors Windsor Windows & Doors 900 S. 19 th St. 2210 Stafford St. Extn

More information

Tools required by installer: Materials required by installer:

Tools required by installer: Materials required by installer: Installation Guidelines For Quaker Window Products Vinyl product line (Single Hung, Double Hung, Sliding Window, Fixed Window, Casement, Awning, and Hopper) Installer: Read these instructions completely

More information

FOLDING DOOR - FOR FACTORY ASSEMBLED JAMBS WITH APPLIED SILL

FOLDING DOOR - FOR FACTORY ASSEMBLED JAMBS WITH APPLIED SILL FOLDING DOOR - FOR FACTORY ASSEMBLED JAMBS WITH APPLIED SILL READ SPECIFIC INSTALLATION INSTRUCTIONS COMPLETELY BEFORE STARTING ANY INSTALLATION Failure to install and maintain our product according to

More information

INSTALLATION INSTRUCTIONS FOR REPLACEMENT FORGENT WOOD GLASTRA WINDOWS RECOMMENDATIONS FOR COMMON INSTALLATION OF ALL REPLACEMENT WINDOWS.

INSTALLATION INSTRUCTIONS FOR REPLACEMENT FORGENT WOOD GLASTRA WINDOWS RECOMMENDATIONS FOR COMMON INSTALLATION OF ALL REPLACEMENT WINDOWS. INSTALLATION INSTRUCTIONS FOR REPLACEMENT FORGENT WOOD GLASTRA WINDOWS RECOMMENDATIONS FOR COMMON INSTALLATION OF ALL REPLACEMENT WINDOWS. Installer: DO NOT DISCARD Please leave the Installation Guide

More information

Reglazing Guide for Andersen 400 Series Specialty Windows with Stormwatch Protection (High-Performance Impact Resistant Glass)

Reglazing Guide for Andersen 400 Series Specialty Windows with Stormwatch Protection (High-Performance Impact Resistant Glass) Reglazing Guide for Andersen 400 Series Specialty Windows with Stormwatch Protection (High-Performance Impact Resistant Glass) INSTALLER: This reglazing procedure is to be performed only by a professional

More information

INSTALLATION INSTRUCTIONS - INSTRUCCIONES DE INSTALACION FOR HURRICANESHIELD IMPACT-RESISTANT DOUBLE-HUNG, SINGLE-HUNG AND SIMULATED-HUNG

INSTALLATION INSTRUCTIONS - INSTRUCCIONES DE INSTALACION FOR HURRICANESHIELD IMPACT-RESISTANT DOUBLE-HUNG, SINGLE-HUNG AND SIMULATED-HUNG 2008 Pella Corporation Part Number: 80ED0101 INSTALLATION INSTRUCTIONS - INSTRUCCIONES DE INSTALACION FOR HURRICANESHIELD IMPACT-RESISTANT DOUBLE-HUNG, SINGLE-HUNG AND SIMULATED-HUNG Instrucciones en español

More information

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit. Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit. Installer: Read these instructions completely before starting any installation.

More information

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) ImpOrTaNT INFOrmaTION & GlOssary.

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) ImpOrTaNT INFOrmaTION & GlOssary. for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) Thank you for selecting JELD -WEN products. Attached are JELD-WEN s recommended installation instructions for metal clad wood windows

More information

Sun Windows General Information New Construction Hinged Door Installation Instructions

Sun Windows General Information New Construction Hinged Door Installation Instructions A G H F H H A. Apply Weather Resistive Barrier B. Apply Bottom Flashing Tape C. Install Sill Pan End Caps & Pan D. Caulk Sides & Top Nailing Surface, Set Door, Fasten E. Apply Side Flashing Tape F. Apply

More information

Integrity Polygon and Round Top Installation and Finishing Instructions

Integrity Polygon and Round Top Installation and Finishing Instructions Integrity Polygon and Round Top Installation and Finishing Instructions 08/20/2004 70852 BEFORE YOU BEGIN IMPORTANT: Read these instructions thoroughly before beginning to install your Integrity Polygon

More information

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR www.quakerwindows.comv www.quakercommercialwindows.com PO Box 128 504 Highway 63 South Freeburg, MO 65035 800-347-0438 573-469-4151 (fax) Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

More information

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows with Exterior Trim or Nail Fin (JII024)

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows with Exterior Trim or Nail Fin (JII024) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for metal clad wood windows with nailing fin or primed wood windows with exterior trim. While the

More information

Passive Panel Replacement

Passive Panel Replacement Passive Panel Replacement Product Series: 200 Series Product Type: Hinged Inswing Patio Doors Read these instructions before starting procedure. For additional information visit www.andersenwindows.com.

More information

HR175 Sash Replacement Kit Installation Instructions

HR175 Sash Replacement Kit Installation Instructions HR175 Sash Replacement Kit Installation Instructions IMPORTANT: Please read before you begin. Weather Shield HR175 Sash Replacement Kits Important: Thoroughly read and follow these instructions, failure

More information

Sun Windows General Information New Construction Sliding Door Installation Instructions H F

Sun Windows General Information New Construction Sliding Door Installation Instructions H F A G B D C H F H E H A. Apply Weather Resistive Barrier B. Apply Bottom Flashing Tape C. Install Sill Pan End Caps & Pan D. Caulk Sides & Top Nailing Surface, Set Door, Fasten E. Apply Side Flashing Tape

More information

Eagle clad double-hung window installation instructions

Eagle clad double-hung window installation instructions Eagle clad double-hung window installation instructions These instructions are for typical installation in new typical wood frame wall construction. These instructions and methods are not intended for

More information

WINDOW REPLACEMENT INSTRUCTIONS FOR CASEMENT, DOUBLE-HUNG AND CLAD FRAME WINDOWS USING FRAME SCREWS

WINDOW REPLACEMENT INSTRUCTIONS FOR CASEMENT, DOUBLE-HUNG AND CLAD FRAME WINDOWS USING FRAME SCREWS WINDOW REPLACEMENT INSTRUCTIONS FOR CASEMENT, DOUBLE-HUNG AND CLAD FRAME WINDOWS USING FRAME SCREWS These instructions were tested developed for replacing windows in wood-frame wall construction systems

More information

INSTALLATION INSTRUCTIONS DOUBLE-HUNG WINDOW WITH FINS

INSTALLATION INSTRUCTIONS DOUBLE-HUNG WINDOW WITH FINS 2012 Pella Corporation INSTALLATION INSTRUCTIONS DOUBLE-HUNG WINDOW WITH FINS Part Number: 802L0105 Installation Instructions for Typical Wood Frame Construction. These instructions were developed tested

More information

Block Frame Inovo Patio Door/Transom/Sidelite Field Mulling Instructions. simonton.com/installation. If mulling sidelites, skip to Step 5.

Block Frame Inovo Patio Door/Transom/Sidelite Field Mulling Instructions. simonton.com/installation. If mulling sidelites, skip to Step 5. Effective Date: 10/1/17 Tools Needed Kit Contents Safety Glasses Cordless Drill Phillips Screw Bit Two-step Drill Bit (3/8-1/8 ) Utility Knife Interior Mullion Exterior Mullion Cover Hardware Kit Clamps

More information

4. Partially open the operating panel and tilt the top toward the interior of the door (Figure 4). Lift the panel off the sill and set it aside.

4. Partially open the operating panel and tilt the top toward the interior of the door (Figure 4). Lift the panel off the sill and set it aside. Effective Date: 10/1/2017 Tools Needed Kit Contents Hardware Kit Safety Glasses Cordless drill Phillips screw bit Two-step drill bit (3/8-1/8 ) utility knife Interior Mullion Exterior Mullion Cover clamps

More information

INSTALLATION INSTRUCTIONS FOR FORGENT SLIDING PATIO DOORS RECOMMENDATIONS FOR COMMON INSTALLATION OF SLIDING PATIO DOORS.

INSTALLATION INSTRUCTIONS FOR FORGENT SLIDING PATIO DOORS RECOMMENDATIONS FOR COMMON INSTALLATION OF SLIDING PATIO DOORS. INSTALLATION INSTRUCTIONS FOR FORGENT SLIDING PATIO DOORS RECOMMENDATIONS FOR COMMON INSTALLATION OF SLIDING PATIO DOORS. Installer: DO NOT DISCARD Please leave the Installation Guide with the home owner

More information

INSTALLATION INSTRUCTIONS for Custom and Premium Pocket Windows (JII022) IMPORTANT INFORMATION AND GLOSSARY SAFETY AND HANDLING

INSTALLATION INSTRUCTIONS for Custom and Premium Pocket Windows (JII022) IMPORTANT INFORMATION AND GLOSSARY SAFETY AND HANDLING Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for pocket (replacement) double-hung, casement, awning, picture or transom windows, designed to

More information

INSTALLATION INSTRUCTIONS FOR TEUTONIC ENTRANCE DOOR RECOMMENDATIONS FOR COMMON INSTALLATION OF ENTRANCE DOORS.

INSTALLATION INSTRUCTIONS FOR TEUTONIC ENTRANCE DOOR RECOMMENDATIONS FOR COMMON INSTALLATION OF ENTRANCE DOORS. INSTALLATION INSTRUCTIONS FOR TEUTONIC ENTRANCE DOOR RECOMMENDATIONS FOR COMMON INSTALLATION OF ENTRANCE DOORS. Installer: DO NOT DISCARD Please leave the Installation Guide with the owner. Please read

More information

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement 1 Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement The following instructions are a supplement

More information

VYTEX PREMIUM SLIDING GLASS DOOR. Table of Contents. Precautions and Safety 2. Tools Required...3. Inspect and Prepare Door...4

VYTEX PREMIUM SLIDING GLASS DOOR. Table of Contents. Precautions and Safety 2. Tools Required...3. Inspect and Prepare Door...4 VYTEX PREMIUM SLIDING GLASS DOOR Table of Contents Precautions and Safety 2 Tools Required...3 Inspect and Prepare Door...4 Hardware and Parts Check List....4 Master Frame Assembly 5 Master Frame Installation..7

More information

Vinyl Windows and Doors Manufactured by Pella Corporation

Vinyl Windows and Doors Manufactured by Pella Corporation Vinyl Windows and Doors Manufactured by Pella Corporation Part Number: V981255 2009 Pella Corporation INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACIÓN FOR BOW WINDOWS WITHOUT HEAD AND SEAT BOARD

More information

Sash may be heavy. Use a reasonable number of people with sufficient strength to lift, carry, remove and install. Tape broken glass with duct tape bef

Sash may be heavy. Use a reasonable number of people with sufficient strength to lift, carry, remove and install. Tape broken glass with duct tape bef Improper re-glazing product (s) can affect the performance under stress and may contribute to property damage or injury in high wind conditions. The installer should not proceed with re-glazing if these

More information

NEW CONSTRUCTION, REPLACEMENT AND FLUSH FIN REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS

NEW CONSTRUCTION, REPLACEMENT AND FLUSH FIN REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS NEW CONSTUCTION, REPLACEMENT & FLUSH FIN WINDOWS NEW CONSTRUCTION, REPLACEMENT AND FLUSH FIN REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS IMPORTANT! READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION.

More information

VISTALUXE CASEMENT, AWNING, & PICTURE WINDOW

VISTALUXE CASEMENT, AWNING, & PICTURE WINDOW VCSMT VISTALUXE CASEMENT, AWNING, & PICTURE WINDOW INSTALLATION INSTRUCTIONS READ THESE INSTRUCTIONS COMPLETELY BEFORE ATTEMPTING ANY INSTALLATION Kolbe & Kolbe Millwork, Co., Inc. 1323 S. 11th Ave. -

More information

Vinyl Windows and Doors

Vinyl Windows and Doors Vinyl Windows and Doors Part Number: V983571 2011 Pella Corporation INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION 350 SERIES WINDOW INTO EXISTING WOOD FRAME WINDOW Lea las instrucciones en español

More information

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032)

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032) for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII0) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for wood and clad wood bay

More information

Flashing Materials. Rough Opening Preparation

Flashing Materials. Rough Opening Preparation Installation Instructions for CertainTeed New Construction Windows Handling vinyl windows CAUTION: Always store vinyl windows and doors in an upright position on a slight angle. Never lay them flat or

More information

INSTALLATION INSTRUCTION FOR WOOD DOUBLE-HUNG AND CASEMENT WINDOWS USING WOOD BRICKMOULD OR FLAT CASING

INSTALLATION INSTRUCTION FOR WOOD DOUBLE-HUNG AND CASEMENT WINDOWS USING WOOD BRICKMOULD OR FLAT CASING 2009 Pella Corporation Part Number: 80DZ0101 INSTALLATION INSTRUCTION FOR WOOD DOUBLE-HUNG AND CASEMENT WINDOWS USING WOOD BRICKMOULD OR FLAT CASING Brickmould/Flat Casing Aluminum Head Flashing Corner

More information

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACIÓN FOR CLAD SLIDING PATIO DOOR PUERTA CORREDERA PARA PATIO

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACIÓN FOR CLAD SLIDING PATIO DOOR PUERTA CORREDERA PARA PATIO 2008 Pella Corporation Part Number: 801W0103 INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACIÓN FOR CLAD SLIDING PATIO DOOR PUERTA CORREDERA PARA PATIO Corner Fin Corner Door Top Nailing Fin Side

More information

Vinyl Windows and Doors

Vinyl Windows and Doors Vinyl Windows and Doors Part Number: V983570 2011 Pella Corporation INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION 350 SERIES WINDOW WITH NAIL FIN Lea las instrucciones en español en el reverso.

More information

Vinyl Windows Manufactured by VPI Quality Windows

Vinyl Windows Manufactured by VPI Quality Windows Vinyl Windows Manufactured by VPI Quality Windows Part Number: 531&591 Installation 531 & 591 SERIES SLIDING AND HUNG WINDOW INSTALLATION INSTRUCTIONS Installation Instructions for Typical Construction.

More information

Passive Panel Replacement Guide

Passive Panel Replacement Guide Replacement Guide for Andersen 200 Series d Patio Doors - Inswing For questions call 1-888-888-7020. For more information and/or guides visit andersenwindows.com. Please leave this guide with building

More information

Vinyl Windows and Doors

Vinyl Windows and Doors Vinyl Windows and Doors Manufactured by Pella Corporation Installation Instructions for Replacement of Aluminum Sliding Doors in Hard Coat Stucco Applications. Part Number: V981555 2009 Pella Corporation

More information

INTERIOR. Checkrail. Flashing tape

INTERIOR. Checkrail. Flashing tape Pella Corporation 2007 Part Number: 808F0100 INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR PELLA PRECISION FIT DOUBLE-HUNG VENT WINDOW PARA LA VENTANA DE GUILLOTINA CON HOJA PRACTICABLE PRECISION

More information

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE This instruction guide provides the minimum recommended procedures to correctly prepare the rough opening, install a fold-a-way patio door unit and apply

More information

INSTALLATION INSTRUCTION INSTRUCCIONES DE INSTALACIÓN FOR CLAD HINGED PATIO DOOR PUERTA DE BISAGRA PARA PATIO

INSTALLATION INSTRUCTION INSTRUCCIONES DE INSTALACIÓN FOR CLAD HINGED PATIO DOOR PUERTA DE BISAGRA PARA PATIO 2008 Pella Corporation Part Number: 801V0101 INSTALLATION INSTRUCTION INSTRUCCIONES DE INSTALACIÓN FOR CLAD HINGED PATIO DOOR PUERTA DE BISAGRA PARA PATIO REMEMBER TO USE APPROPRIATE PERSONAL PROTECTIVE

More information

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS 1290363 Revision 1 12/16 Page 1 Weather Shield Mfg., Inc. NOTICE CAUTION! Failure to install and maintain our product according to these instructions

More information

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nailing fin. While the use of these installation instructions

More information

Vinyl Windows and Doors

Vinyl Windows and Doors Vinyl Windows and Doors Manufactured by Pella Corporation WINDOW REPLACEMENT INSTRUCTIONS FOR SINGLE-HUNG AND SLIDING WINDOWS INTO EXISTING CASEMENT FRAME Part Number: V981203 2009 Pella Corporation USING

More information

INSTALLATION INSTRUCTION FOR CLAD BOW WINDOWS WITHOUT HEAD AND SEAT BOARD

INSTALLATION INSTRUCTION FOR CLAD BOW WINDOWS WITHOUT HEAD AND SEAT BOARD 2008 Pella Corporation Part Number: 80KG0101 INSTALLATION INSTRUCTION FOR CLAD BOW WINDOWS WITHOUT HEAD AND SEAT BOARD Note: These instructions may be used for all Pella Bow windows that do not have a

More information

Sliding Glass Door Assembly and Installation Guide

Sliding Glass Door Assembly and Installation Guide Sliding Glass Door Assembly and Installation Guide Index Door System Components and Hardware The following components are needed to complete the installation of your Sliding Patio Door unit. Check all

More information

Replacement Guide. For Handle Side Z-bar on Fullview Doors with Laminated Glass and Multi-Point Locking System RECOMMENDED TOOLS:

Replacement Guide. For Handle Side Z-bar on Fullview Doors with Laminated Glass and Multi-Point Locking System RECOMMENDED TOOLS: Replacement Guide For Handle Side Z-bar on Fullview Doors with Laminated Glass and Multi-Point Locking System IMPORTANT: READ ENTIRE GUIDE BEFORE BEGINNING INSTALLATION. PLEASE NOTE: Proper assembly, installation

More information

VINYL REPLACEMENT WINDOW INSTALLATION STANDARDS

VINYL REPLACEMENT WINDOW INSTALLATION STANDARDS VINYL REPLACEMENT WINDOW INSTALLATION STANDARDS BEFORE you start to remove the existing windows Place clean drop cloths in all work areas. Re-measure the opening to ensure the new window will fit. Remove

More information

NEW CONSTRUCTION PATIO DOOR INSTALLATION INSTRUCTIONS (WITH NAILING FLANGE)

NEW CONSTRUCTION PATIO DOOR INSTALLATION INSTRUCTIONS (WITH NAILING FLANGE) NEW CONSTRUCTION PATIO DOOR INSTALLATION INSTRUCTIONS (WITH NAILING FLANGE) Slim Line & Classic French Style Patio Doors Materials included: (2) #10 x 2-1/2" Phillips Pan head keeper s (2) 3/8" Hole plugs

More information

VINYL WINDOWS (new construction or replacement) page 2. VINYL PATIO DOORS pages WOOD CLAD WINDOWS (new construction).page 5 WOOD CLAD WINDOWS

VINYL WINDOWS (new construction or replacement) page 2. VINYL PATIO DOORS pages WOOD CLAD WINDOWS (new construction).page 5 WOOD CLAD WINDOWS RECOMMENDED INSTALLATION INSTRUCTIONS Please choose the appropriate instructions for the product(s) you are using. Read the instructions thoroughly before beginning the installation process. All instructions

More information

T he Double-Hung Replacement System replaces the sash and balance system of an older double-hung window. The

T he Double-Hung Replacement System replaces the sash and balance system of an older double-hung window. The Double-Hung Replacement System Installation The Pozzi Collection PID001 (12/03) T he Double-Hung Replacement System replaces the sash and balance system of an older double-hung window. The frame of the

More information

INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS

INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS 2012 Pella Corporation Part Number: 80WH0101 INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS Installation Instructions for Typical Wood Frame Construction.

More information

(773) INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GL OSSARY ROUGH OPENINGS

(773) INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GL OSSARY ROUGH OPENINGS Thank you for selecting C l i m a t e G u a r d products. Attached are our recommended installation instructions for Vinyl windows with an integral (2400-02) will not affect application of the ClimateGuard

More information

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION PELLA PRECISION FIT AND RENOVATION POCKET REPLACEMENT DOUBLE-HUNG VENT WINDOW

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION PELLA PRECISION FIT AND RENOVATION POCKET REPLACEMENT DOUBLE-HUNG VENT WINDOW 2011 Pella Corporation INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION PELLA PRECISION FIT AND RENOVATION POCKET REPLACEMENT DOUBLE-HUNG VENT WINDOW Part Number: 808F0105 Important! The Pella Replacement

More information

All Window Installation Instruction

All Window Installation Instruction 1 All Window Installation Instruction Hurd Window Installation Instructions for Nail Fin & Wood Brick Mould Units Nail Fin Windows See Pages 2-11 Wood Brick Mould Windows See Pages 2-6, 8 & 12BM - 14BM

More information

26- H i n g e d P a t i o D o o r s - I n s w i n g

26- H i n g e d P a t i o D o o r s - I n s w i n g Contents Hinged Patio Doors - Inswing Basic Unit Details... 2 Options / Accessories Accessibility Option... 5 Andersen Grilles... 6 Extension s... 7 Anchoring Methods... 8 Joining Details... 9 Suggested

More information

WINDOW REPLACEMENT INSTRUCTIONS FOR SINGLE-HUNG, DOUBLE-HUNG, CASEMENT, AWNING INTO EXISTING CASEMENT FRAME USING FRAME SCREWS

WINDOW REPLACEMENT INSTRUCTIONS FOR SINGLE-HUNG, DOUBLE-HUNG, CASEMENT, AWNING INTO EXISTING CASEMENT FRAME USING FRAME SCREWS 2009 Pella Corporation Part Number: 80YV0102 WINDOW REPLACEMENT INSTRUCTIONS FOR SINGLE-HUNG, DOUBLE-HUNG,, AWNING INTO EXISTING FRAME USING FRAME SCREWS These instructions were tested and developed for

More information

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACIÓN FOR CLAD CASEMENT & AWNING WINDOW VENTANA DE DOS HOJAS CON REVESTIMIENTO

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACIÓN FOR CLAD CASEMENT & AWNING WINDOW VENTANA DE DOS HOJAS CON REVESTIMIENTO 2008 Pella Corporation Part Number: 801P0101 INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACIÓN FOR CLAD CASEMENT & AWNING WINDOW VENTANA DE DOS HOJAS CON REVESTIMIENTO Corner Corner Top Fin Corner

More information

How To Install Windows: Nail-Fin Application

How To Install Windows: Nail-Fin Application How To Install Windows: Nail-Fin Application Required Tools & Materials: Materials: 1 3/4" galvanized roofing nails. Nails must penetrate at least 1" into framing For mulled and/or DP50 or above units:

More information

INOVO 2-LITE SLIDING PATIO DOOR

INOVO 2-LITE SLIDING PATIO DOOR INOVO 2-LITE SLIDING PATIO DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS IMPORTANT: READ THE INSTRUCTIONS AND FAMILIARIZE YOURSELF WITH THE DOOR PARTS AND PIECES BEFORE BEGINNING ASSEMBLY AND INSTALLATION.

More information

1200 SERIES 2 PANEL DOOR rev.1 DETAILED INSTALLATION INTRUCTIONS

1200 SERIES 2 PANEL DOOR rev.1 DETAILED INSTALLATION INTRUCTIONS 1200 SERIES 2 PANEL DOOR 10.2013 rev.1 DETAILED INSTALLATION INTRUCTIONS GENERAL: Door elevations shown in these instructions are as viewed from the outside. X denotes the active or moving panel(s). O

More information