IPA FITTINGS FOR REHAU NORDIC DESIGN A/S J. PETERSENS BESLAGFABRIK JACOB PETERSENSVEJ 9, DK-9240 NIBE TEL: (+45)

Size: px
Start display at page:

Download "IPA FITTINGS FOR REHAU NORDIC DESIGN A/S J. PETERSENS BESLAGFABRIK JACOB PETERSENSVEJ 9, DK-9240 NIBE TEL: (+45)"

Transcription

1 IP FITTINGS FOR REHU NORDIC DESIGN /S J. PETERSENS ESLGFRIK JCO PETERSENSVEJ, DK-240 NIE TEL: (+45)

2

3 3 FITTINGS FOR REHU NORDIC DESIGN Table of contents Profile - REHU Nordic Design 4 PGE FITTINGS IP No mm Window hinge 5 IP No mm Door hinge 6 IP No mm djustable Door hinge 7-8 IP No Fitting for side swing window - 10 IP No Fitting for side swing window - adjustable IP No Reversible Projecting Gears IP No Safety Restrictor IP No Canopy Stay IP No djustable Canopy Stay IP No djustable Canopy Stay - djustable Friction 1-20 IP No Safety Restrictor IP No Friction Stay for Windows 23 IP No Friction Stay for Doors 24 IP No Support Fitting 25 IP No Guide lock 25 IP No Flush olt 25 IP No Casement Hook IP No Casement Hook IP No Hook Catch IP No Casement Fasteners IP No Casement Fasteners Lubrication Instructions 28-2 Espagnolettes 30

4 4 FITTING INSTRUCTIONS REHU NORDIC DESIGN PROFILE

5 5 WINDOW HINGE IP No C MTERIL SURFCE IP NO. STEEL FIXED STEEL PIN STEEL FIXED RSS PIN SQURE EDGES LEFT SQURE EDGES RIGHT GLVNIZED INDUSTRY PCKING IN OXES OF 100 PIECES MM MM C MM MTERIL MM PIN MM SCREW PPROX. WEIGHT KG / PC IP No FITTING INSTRUCTIONS REHU NORDIC DESIGN PROFILE FIG. 1 FIG USE SCREW NO MINTENNCE: TEST THE OPERTION FROM TIME TO TIME. WHEN FITTING - GRESE THE PIVOT/MOVLE METL PRTS OF THE MECHNISM WHILE CTIVTING REPETEDLY. HEREFTER GRESE MINIMUM TWICE YER. SEE LSO INSTRUCTIONS ON PGE 28-2.

6 6 DOOR HINGE IP No C MTERIL SURFCE IP NO. STEEL FIXED STEEL PIN STEEL FIXED RSS PIN SQURE EDGES LEFT SQURE EDGES RIGHT GLVNIZED INDUSTRY PCKING IN OXES OF 50 PIECES MM MM C MM MTERIL MM PIN MM SCREW PPROX. WEIGHT KG / PC. IP No FITTING INSTRUCTIONS 16 REHU NORDIC DESIGN PROFILE FIG. 1 FIG USE SCREW NO MINTENNCE: TEST THE OPERTION FROM TIME TO TIME. WHEN FITTING - GRESE THE PIVOT/MOVLE METL PRTS OF THE MECHNISM WHILE CTIVTING REPETEDLY. HEREFTER GRESE MINIMUM TWICE YER. SEE LSO INSTRUCTIONS ON PGE 28-2.

7 7 DJUSTLE DOOR HINGE IP No MTERIL SURFCE IP NO. STEEL FIXED STEEL PIN SQURE EDGES LEFT SQURE EDGES RIGHT GLVNIZED INDUSTRY PCKING IN OXES OF 50 PIECES MM MM C MM MTERIL MM PIN MM SCREW PPROX. WEIGHT KG / PC DJUSTLE HORISONTLLY ND VERTICLLY C RIGHT

8 8 IP No FITTING INSTRUCTIONS UPPER HINGE PRT REHU NORDIC DESIGN PROFILE LOWER HINGE PRT FIG DJUSTMENT PLTE FITTING: 1. MOUNT THE DJUSTMENT PLTE IN THE GROOVE OF THE DOOR IN THE MIDDLE OF WHERE THE LOWER HINGE PRT IS EING MOUNTED. 2. PLCE HINGE SO THT THE LOWER HINGE PRT IS OVER THE DJUSTMENT PLTE ND FSTEN IT. THE DJUSTMENT SCREWS SHOULD E LOOSENED FIG. 2 DJUSTMENT: VERTICLLY: DJUST TO WNTED POSITION ON THE LRGE SCREW T THE OTTOM OF THE HINGE - ±3 MM. HORIZONTLLY: LOOSEN THE MOUNTING SCREWS ND DJUST TO WNTED POSITION. FSTEN THE MOUNTING SCREWS. MINTENNCE: TEST THE OPERTION FROM TIME TO TIME. WHEN FITTING - GRESE THE PIVOT/MOVLE METL PRTS OF THE MECHNISM WHILE CTIVTING REPETEDLY. HEREFTER GRESE MINIMUM TWICE YER. SEE LSO INSTRUCTIONS ON PGE 28-2.

9 SIDE SWING WINDOW 0 0 WITH FRICTION IP No MTERIL SURFCE IP NO. STEEL LEFT RIGHT ELECTROPLTED STNDRDPCKING IN OXES OF 5 SETS MM MM C MM SCREW PPROX. WEIGHT KG / SET DJUSTLE FRICTION CONVENIENT FOR CLENING SWINGS 0 OPENS CLER FROM CURTINS ND WINDOW FRME MX. VENTILTION CONCELED FITTINGS NODIZED LUMINIUM RILS C TOP FITTING OTTOM FITTING 1 SET RIGHT HND FIRE-ESCPE OPENING: 500 MM FROM SSH HEIGHT 726 MM

10 10 IP No FITTING INSTRUCTIONS REHU NORDIC DESIGN PROFILE FIG. 2 HORIZONTL PLN HINGE SIDE FITTING SHOWN ON FRME CILL RIGHT HND ILLUSTRTION IP NO MX. SSH WEIGHT KGS 40 FIG. 1 VERTICL PLN MIN. SSH WIDTH 315 MX. SSH WIDTH 820 SCREW 4,0 FIG. 3 FITTING: 1. THE FITTING SHOULD E POSITIONED IN THE GROOVES T HED ND CILL OF FRME ND SCREWED ON (FIGURE 1 ND 2) 2. NOW PUSH THE WINDOW SSH INTO POSITION Y SSH SLOTS ND FSTEN THE SCREWS. 3. THE FRICTION CN NOW E DJUSTED ON THE TOP FITTING. IF LRGER OPENING IS WNTED THEN JUST MOVE THE DJUSTLE STOP FITTING IN THE TOP FRME LUMINIUM RIL. MINTENNCE: THE FITTINGS RE NOT TO E PINTED. TEST THE OPERTION FROM TIME TO TIME. WHEN FITTING - LURICTE THE PIVOT/MOVLE METL PRTS OF THE MECHNISM WHILE CTIVTING REPETEDLY. HEREFTER LURICTE MINIMUM TWICE YER. DO NOT LURICTE THE LUMINIUM RILS. SEE LSO INSTRUCTIONS ON PGE 28-2.

11 SIDE SWING WINDOW 0 0 WITH FRICTION IP NO adjustable 11 IP NO. MTERIL STEEL LEFT RIGHT SURFCE ELECTROPLTED STNDRD PCKING IN OXES OF 5 SETS , MM MM C MM SCREW WEIGHT PPROX. KG / SET DJUSTLE FRICTION CONVENIENT FOR CLENING SWINGS 0 OPENS CLER FROM CURTINS ND WINDOW FRME MX. VENTILTION CONCELED FITTINGS NODIZED LUMINIUM RILS C TOP FITTING OTTOM FITTING FIRE-ESCPE OPENING IP NR. 6276: 500 MM FROM SSH HEIGHT 706 MM 1 SET RIGHT FIRE-ESCPE OPENING IP NR. 6277: 500 MM FROM SSH HEIGHT 750 MM 600 MM FROM SSH HEIGHT 855 MM

12 12 IP NO FITTING INSTRUCTIONS 16 REHU NORDIC DESIGN PROFILE ECCENTRIC SCREW FITTING SHOWN ON TOP FRME CILL - RIGHT HND ILLUSTRTION DJUSTMENT PLTE MRK HINGE SIDE 16.5 FIG. 2 HORIZONTL PLN FITTING SHOWN ON OTTOM FRME CILL - RIGHT HND ILLUSTRTION HINGE SIDE FITTING: FIG. 1 VERTICL PLN IP NO MX. SSH WEIGHT KGS MIN. SSH WIDTH MX. SSH WIDTH SCREW FIG THE FITTING SHOULD E POSITIONED IN THE GROOVES T HED ND CILL OF FRME ND SCREWED ON (FIGURE 1 ND 2) 2. NOW PUSH THE WINDOW SSH INTO POSITION Y SSH SLOTS ND FSTEN THE SCREWS. 3. THE FRICTION CN NOW E DJUSTED ON THE TOP FITTING. IF LRGER OPENING IS WNTED THEN JUST MOVE THE DJUSTLE STOP FITTING IN THE TOP FRME LUMINIUM RIL. 4. THE SSH CN E DJUSTED ±1.5 MM SIDEWYS. EFORE NY DJUSTMENT THE MOUNTING SCREW IN THE DJUSTMENT PLTE IN THE TOP OF THE FRME HVE TO E LOOSENED. THEN DJUST Y USING TORX-20 KEY TO TURN THE ECCENTRIC SCREW. Y DELIVERY THE MRK ON THE ECCENTRIC SCREW IS IN 0 0 POSITION COMPRED TO THE FITTING, WHICH INDICTING THE 0-POSITION. THE ECCENTRIC SCREW CN E TURNED 0 0 TO ECH SIDE, WHICH GIVES THE MXIMUM DJUSTMENT OF 1½ MM. FTER THE DJUSTMENT THE MOUNTINGSCREW IN THE DJUSTMENT PLTE IS FSTENED. MINTENNCE: THE FITTINGS RE NOT TO E PINTED. TEST THE OPERTION FROM TIME TO TIME. WHEN FITTING - LURICTE THE PIVOT/MOVLE METL PRTS OF THE MECHNISM WHILE CTIVTING REPETEDLY. HEREFTER LURICTE MINIMUM TWICE YER. DO NOT LURICTE THE LUMINIUM RILS. SEE LSO INSTRUCTIONS ON PGE 28-2.

13 REVERSILE PROJECTING GER IP No IP NO. MTERIL STEEL WITHOUT SPECIFICTION SURFCE ELECTROPLTED STNDRD PCKING IN OXES OF 1 SET MM MM FRME DIMENSION OUTSIDE MM SCREW PPROX. WEIGHT KG / SET /2 SET CONCELED FITTINGS FULLY REVERSILE OPENS CLER OF CURTINS ND WINDOW FRME DJUSTLE FRICTION NODIZED RILS FIRE-ESCPE OPENING: 500 MM FROM SSH HEIGHT 826 MM 600 MM FROM SSH HEIGHT 1026 MM MTERIL SURFCE IP NO. STEEL LEFT ELECTROPLTED STNDRD PCKING IN OXES OF 20 PCS. MM SCREW PPROX. WEIGHT KG / PC SFETY CTCH IP NO

14 14 IP No.s FITTING INSTRUCTIONS 26 FIG. 2 TOP FRME 16 REHU NORDIC DESIGN PROFILE FIG. 3 FRME SIDE SSH SIDE TOP SSH IP NO IP NO. FITTING LENGTH MM FITTING ON FRME FIG. 1 MX. WEIGHT KGS USE THE LGEST POSSILE FITTING SSH , FITTING: 1. PLCE FITTING INTO OTH SIDES OF THE FRME. 2. POSITION FITTING GINST TOP FRME ND FSTEN. 3. PLCE THE ERING PLTE GINST THE TOP ND GINST THE LUMINIUM RIL ND FSTEN. 4. INSERT THE SSH ETWEEN HINGE RMS ND PUSH THE SSH GINST THE STOP RCKET. FSTEN THE SSH STRTING WITH THE SCREW IN THE STOP RCKET. 5. NOW THE FRICTION CN E DJUSTED Y MENS OF THE SCREWS T THE OTTOM OF THE LU-RILS. THE FRICTION HS TO E THE SME ON OTH SIDES. 6. FIT THE RESTRICTOR IP NO ON THE LEFT SIDE, SEE FIG. 1. USE SCREW NO OPERTION INSTRUCTIONS: 1. OPEN THE WINDOW - THE RESTRICTOR WILL UTOMTICLLY RESTRICT THE WINDOW. 2. PULL THE SSH 20 MM - PRESS THE RESTRICTOR IN THE DIRECTION OF THE RROW ND OPEN THE WINDOW. 3. WHEN THE WINDOW IS REVERSED FOR CLENING, THE RESTRICTOR WITH LOCK UTOMTICLLY. DISENGGE S MENTIONED IN POINT 2. MINTENNCE: THE FITTINGS RE NOT TO E PINTED. WHEN FITTING - LURICTE THE PIVOT/MOVLE METL PRTS OF THE MECHNISM WHILE CTIVTING REPETEDLY. HERFTER LIRICTE MINIMUM TWICE YER. DO NOT GRESE THE LUMINIUM RILS. TEST THE OPERTION FROM TIME TO TIME. SEE LSO INSTRUCTIONS ON PGE

15 CNOPY STY WITH FRICTION IP No MTERIL SURFCE IP NO. STEEL W/O SPECIFICTION ELECTROPLTED STNDRDPCKING IN OXES OF 5 SETS INDUSTRY PCKING IN OXES OF 25 SETS MM MM SCREW PPROX. WEIGHT KG / SET CONCELED FITTINGS DJUSTLE FRICTION NODIZED LUMINIUM RILS THE MOVEMENT GEOMETRY ENSURES MXIMUM SELING 1/2 SET FIRE-ESCPE OPENING: IP NO MM FROM SSH HEIGHT 826 MM IP NO MM FROM SSH HEIGHT 26 MM 600 MM FROM SSH HEIGHT 1026 MM IP NO MM FROM SSH HEIGHT 1126 MM 600 MM FROM SSH HEIGHT 1326 MM

16 16 IP No FITTING INSTRUCTIONS REHU NORDIC DESIGN PROFILE VERTICL PLN FIG FIG. 2 IP NO MX. SSH WEIGHT KGS MX. SSH HEIGHT MM SCREW FITTING: 1. CLOSE THE FITTING ND PLCE IT IN THE GROOVE OF THE SIDE FRME. PLCE THE FITTING GINST THE TOP FRME. PLCE ND FSTEN THE SCREW IN THE OTTOM HOLE OF THE FITTING. OPEN THE FITTING ND FSTEN THE REMINING SCREWS. ON IP NO MOUNT THE STOPPLTE THROUGH THE UPPER SCREWHOLE UNDER THE SLIDDING ELEMENT. 2. PUSH THE SSH INTO ITS PLCE Y INSERTING IT ETWEEN THE FITTINGS, GUIDED Y THE GROOVES IN THE SSH, TILL THE SSH HITS THE STOPS OF THE FITTING. THESE STOPS WILL GURNTEE 5 MM G ETWEEN FRME ND SSH. FSTEN THE FITTING STRTING WITH THE SCREW IN THE STOP RCKET (IP NO ). 3. NOW THE FRICTION MY E DJUSTED Y MENS OF THE SCREWS IN THE SLIDES. THE EST RESULT FOR THE WINDOW MOVEMENT IS CHIEVED Y EQUL FRICTION T EITHER SIDE. MINTENNCE: THE FITTINGS RE NOT TO E PINTED. TEST THE OPERTION FROM TIME TO TIME. WHEN FITTING - LURICTE THE PIVOT/MOVLE METL PRTS OF THE MECHNISM WHILE CTIVTING REPETEDLY. HEREFTER LURICTE MINIMUM TWICE YER. DO NOT LURICTE THE LUMINIUM RILS. SEE LSO INSTRUCTIONS ON PGE FIG. 3

17 DJUSTLE CNOPY STY WITH FRICTION IP No IP NO. MTERIL STEEL W/O SPECIFICTION SURFCE ELECTROPLTED STNDRD PCKING IN OXES OF 5 SETS INDUSTRY PCKING IN OXES OF 25 SETS MM MM SCREW PPROX. WEIGHT KG / SET /2 SET VERTICLLY DJUSTLE ± 1.5 MM CONCELED FITTINGS DJUSTLE FRICTION NODIZED LUMINIUM RILS THE MOVEMENT GEOMETRY ENSURES MXIMUM SELING FIRE-ESCPE OPENING: IP NO MM FROM SSH HEIGHT 826 MM IP NO MM FROM SSH HEIGHT 26 MM 600 MM FROM SSH HEIGHT 1026 MM IP NO MM FROM SSH HEIGHT 1126 MM 600 MM FROM SSH HEIGHT 1326 MM

18 18 IP No FITTING INSTRUCTIONS REHU NORDIC DESIGN PROFILE VERTICL PLN FIG FIG. 2 IP N MX. SSH WEIGHT KGS MX. SSH HEIGHT MM SCREW FITTING: 1. CLOSE THE FITTING ND PLCE IT IN THE GROOVE OF THE SIDE FRME. PLCE THE FITTING GINST THE TOP FRME. PLCE ND FSTEN THE SCREW IN THE OTTOM HOLE OF THE FITTING. OPEN THE FITTING ND FSTEN THE REMINING SCREWS. 2. PUSH THE SSH INTO ITS PLCE Y INSERTING IT ETWEEN THE FITTINGS, GUIDED Y THE GROOVES IN THE SSH, TILL THE SSH HITS THE STOPS OF THE FITTING. THESE STOPS WILL GURNTEE 5 MM G ETWEEN FRME ND SSH. FSTEN THE FITTING STRTING WITH THE SCREW IN THE STOP RCKET 3. NOW THE FRICTION MY E DJUSTED Y MENS OF THE SCREWS IN THE SLIDES. THE EST RESULT FOR THE WINDOW MOVEMENT IS CHIEVED Y EQUL FRICTION T EITHER SIDE. 4. THE SSH CN E DJUSTED ±1.5 MM UP OR DOWN. EFORE NY DJUSTMENT THE MOUNTING SCREWS IN THE OTTOM IN ECH SIDE OF THE FRME HVE TO E LOOSENED. THEN DJUST Y USING TORX-20 KEY TO TURN THE ECCENTRIC SCREW. Y DELIVERY THE MRK ON THE ECCENTRIC SCREW IS IN VERTICL PERSITION INDICTING THE 0-POSITION. WHEN THE MRK IS IN HORIZONTL POSTION IN EITHER TOP OR OTTOM, THE FITTING IS DJUSTED TO IT S MX OF ±1.5 MM. FTER THE DJUSTMENT THE MOUNTINGSCREWS IN THE OTTOM OF ECH SIDE RE FSTENED. ECCENTRIC SCREW MRK FIG. 3 MINTENNCE: THE FITTINGS RE NOT TO E PINTED. TEST THE OPERTION FROM TIME TO TIME. WHEN FITTING - LURICTE THE PIVOT/MOVLE METL PRTS OF THE MECHNISM WHILE CTIVTING REPETEDLY. HEREFTER LURICTE MINIMUM TWICE YER. DO NOT LURICTE THE LUMINIUM RILS. SEE LSO INSTRUCTIONS ON PGE 28-2.

19 DJUSTLE CNOPY STY WITH DJUSTLE FRICTION IP No MTERIL SURFCE IP NO. STEEL W/O SPECIFICTION ELECTROPLTED STNDRD PCKING IN OXES OF 5 SETS MM MM SCREW PPROX. WEIGHT KG / SET /2 SÆT VERTICLLY DJUSTLE ± 1.5 MM DJUSTLE FRICTION CONCELED FITTINGS NODIZED LUMINIUM RILS THE MOVEMENT GEOMETRY ENSURES MXIMUM SELING FIRE-ESCPE OPENING: IP NO MM FROM SSH HEIGHT 626 MM 600 MM FROM SSH HEIGHT 726 MM

20 20 IP No FITTING INSTRUCTIONS REHU NORDIC DESIGN PROFILE VERTICL PLN FIG FIG. 2 IP NO FITTING: 1. CLOSE THE FITTING ND PLCE IT IN THE GROOVE OF THE SIDE FRME. PLCE THE FITTING GINST THE TOP FRME. PLCE ND FSTEN THE SCREW IN THE OTTOM HOLE OF THE FITTING. OPEN THE FITTING ND FSTEN THE REMINING SCREWS. MX. SSH WEIGHT KG 50 MX. SSH HEIGHT MM 40 SCREW PUSH THE SSH INTO ITS PLCE Y INSERTING IT ETWEEN THE FITTINGS, GUIDED Y THE GROOVES IN THE SSH, TILL THE SSH HITS THE STOPS OF THE FITTING. FSTEN THE FITTING STRTING WITH THE SCREW IN THE STOP RCKET 3. NOW THE FRICTION MY E DJUSTED Y MENS OF THE SCREWS IN THE SLIDES. WHEN DJUSTING LET THE TOP GLIDER MOVE DOWN TO THE STOP. THE EST RESULT FOR THE WINDOW MOVEMENT IS CHIEVED Y EQUL FRICTION T EITHER SIDE. 4. THE SSH CN E DJUSTED ±1.5 MM UP OR DOWN. EFORE NY DJUSTMENT THE MOUNTING SCREWS IN THE OTTOM IN ECH SIDE OF THE FRME HVE TO E LOOSENED. THEN DJUST Y USING TORX-20 KEY TO TURN THE ECCENTRIC SCREW. Y DELIVERY THE MRK ON THE ECCENTRIC SCREW IS IN VERTICL PERSITION INDICTING THE 0-POSITION. WHEN THE MRK IS IN HORIZONTL POSTION IN EITHER TOP OR OTTOM, THE FITTING IS DJUSTED TO IT S MX OF ±1.5 MM. FTER THE DJUSTMENT THE MOUNTINGSCREWS IN THE OTTOM OF ECH SIDE RE FSTENED. ECCENTRIC SCREW MINTENNCE: THE FITTINGS RE NOT TO E PINTED. TEST THE OPERTION FROM TIME TO TIME. WHEN FITTING - LURICTE THE PIVOT/MOVLE METL PRTS OF THE MECHNISM WHILE CTIVTING REPETEDLY. HEREFTER LURICTE MINIMUM TWICE YER. DO NOT LURICTE THE LUMINIUM RILS. SEE LSO INSTRUCTIONS ON PGE MRK FIG. 3

21 21 SFETY CTCH IP No MTERIL SURFCE IP NO. STEEL LEFT RIGHT ELECTROPLTED STNDRDPCKING IN OXES OF 5 SETS MM SCREW PPROX. WEIGHT KG / SET 1 SET RIGHT

22 22 IP No FITTING INSTRUCTIONS REHU NORDIC DESIGN PROFILE MRK X + 86 SSH 26 X OTTOM FRME SIDE SSH FIG. 1 RIGHT HND ILLUSTRTION FIG THE FITTING CN E USED ON OTH TOPHUNG/TOPGUIDED S WELL S SIDEHUNG/SIDEGUIDED WINDOWS. ON TOPHUNG/TOPGUIDED WINDOWS THE RESTRICTOR IS PLCED IN THE OTTOM OF THE SIDE FRME ND THE RECEIVER IS PLCED IN THE OTTOM OF THE SIDE SSH. ON THE SIDEHUNG/SIDEGUIDED WINDOWS THE RESTRICTOR IS PLCED IN TOP/OTTOM FRME ON THE OPPOSITE SIDE OF THE HINGES ND THE RECEIVER IS PLCED IN THE TOP/OTTOM SSH OPPOSITE THE HINGES. X-DIMENSION IS OPTIONL. ON TOPHUNG/TOPGUIDED WINDOWS X MUST MINIMUM E 7 MM. Y USING LRGER X-DIMENSION THE VENTILTION OPENING WILL E EXTENDED. IMPORTNT: THE RECEIVER MUST E MOUNTED SO THT IT HITS THE MRK ON THE RESTRICTOR RM WHEN THE WINDOW IS CLOSED. SEE FIG. 1 OPERTING INSTRUCTIONS: 1. OPEN THE WINDOW UNTIL THE RESTRICTOR ENGGES. 2 PULL THE SSH PPROXIMTELY 20 MM CKWRDS. 3. PRESS THE RESTRICTOR OUTWRDS S YOU OPEN THE WINDOW. 4. WHEN THE WINDOW IS CLOSED THE RESTRICTOR RE-ENGGES UTOMTICLLY. USE SCREW NO. 4.0 MINTENNCE: THE FITTINGS RE NOT TO E PINTED. TEST THE OPERTION FROM TIME TO TIME. WHEN FITTING - LURICTE THE PIVOT/MOVLE METL PRTS OF THE MECHNISM WHILE CTIVTING REPETEDLY. HEREFTER LURICTE MINIMUM TWICE YER. DO NOT LURICTE THE LUMINIUM RILS. SEE LSO INSTRUCTIONS ON PGE 28-2.

23 23 FRICTION STY for windows IP No IP NO. MTERIL STEEL W/O SPECIFICTION SURFCE ELECTROPLTED STNDRD PCKING IN OXES OF 25 PCS. MM MM MTERIL MM SCREW PPROX. WEIGHT KG / PC X CONCELED FITTING OPENS UP TILL 100 FRICTION IN LL POSITIONS DJUSTLE FRICTION NODIZED LUMINIUM RIL IP No FITTING INSTRUCTIONS REHU NORDIC DESIGN PROFILE TOP FRME FIG FIG. 1 DJUSTLE FRICTION TOP SSH MINTENNCE: THE FITTING RE NOT TO E PINTED. TEST THE OPERTION FROM TIME TO TIME. WHEN MOUNTING - LURICTE THE PIVOT/MOVLE METL PRTS OF THE MECHNISM WHILE CTIVTING REPETEDLY. HERFTER LURICTE MINIMUM TWICE YER. DO NOT LURICTE THE LUMINIUM RIL. SEE LSO INSTRUCTIONS ON PGE FIG. 3

24 24 FRICTION STY for doors IP No IP NO. MTERIL STEEL W/O SPECIFICTIONS SURFCE ELECTROPLTED STNDRD PCKING IN OXES OF 10 PCS. PPROX. WEIGHT KG / PCS X MM MM MTERIL MM SCREW CONCELED FITTING OPENS UP TILL 100 FRICTION IN LL POSITIONS DJUSTLE FRICTION NODIZED LUMINIUM RIL IP No FITTING INSTRUCTIONS REHU NORDIC DESIGN PROFILE TOP FRME FIG DJUSTLE FRICTION TOP SSH FIG. 1 MINTENNCE: THE FITTING RE NOT TO E PINTED. TEST THE OPERTION FROM TIME TO TIME. WHEN MOUNTING - LURICTE THE PIVOT/MOVLE METL PRTS OF THE MECHNISM WHILE CTIVTING REPETEDLY. HERFTER LURICTE MINIMUM TWICE YER. DO NOT LURICTE THE LUMINIUM RIL. SEE LSO INSTRUCTIONS ON PGE FIG. 3

25 25 CCESSORIES IP No.s 62222, & C SUPPORT FITTING IP NO C GUIDE LOCK IP NO IP N0. MTERIL LUMINIUM PLSTIC W/O SPECIFICTION SURFCE NODIZED GREY STNDRD PCKING IN OXES OF 20 PCS. STNDRD PCKING IN OXES OF 25 PCS. MM MM C MM SCREW HOLES MM SCREW PPROX. WEIGHT KG / PC FLUSH OLT IP NO FLUSH OLT IP NO. 630 IP NO. MTERIL STEEL SQURE EDGES SURFCE ELECTROPLTED STNDRD PCKING IN OXES OF 10 PCS. MM MM THICKNESS MM OLT MM LENGTH OLT MM SCREW PPROX. WEIGHT KG / PC X X

26 26 CSEMENT HOOKS, HOOK CTCH & CSEMENT FSTENERS FITTING INSTRUCTIONS MTERIL SURFCE IP NO. ZINK LLOY WITHOUT SPECIFICTION ELECTROPLTED / WHITE ELECTROPLTED ELECTROPLTED YELLOW STNDRDPCKING IN OXES OF 50 PIECES INDUSTRY PCKING IN OXES OF 250 PIECES MM MM HOLE FOR PIN MM PPROX. WEIGHT KG / 100 PIECES IP NO. MTERIL STEEL RSS W/O SPECIFICTION ELECTROPLTED / WHITE PHOSPH. ROWN SURFCE ELECTROPLTED ELECTROPLTED YELLOW POLISHED STNDRD PCKING IN OXES OF 25 PIECES STNDRD PCKING IN OXES OF 50 PIECES INDUSTRY PCKING IN OXES OF 200 PIECES INDUSTRY PCKING IN OXES OF 250 PIECES INDUSTRY PCKING IN OXES OF 500 PIECES MM MM RING SCREW THRED MM PIN MM SCREW PPROX. WEIGHT KG / 100 PIECES ,

27 27 FITTING INSTRUCTIONS IP NO DRILL 5 MM HOLE FOR RING SCREW IP NO IP NO WITH IP NO WITH IP NO SSH FRME 18 FRME SSH MONTERUNG: 1. MOUNT THE RECEIVER IN THE WNTED HEIGHT ON THE SIDEFRME. 2. IP NO : FOR CSEMENT FSTENERS WITH SCREW PLTE MESURE PRECISELY ON THE SSH ND DRILL 5 MM HOLE FOR THE RING SCREW. MRK UP THE 2 SCREW HOLES ON THE SCREW PLTE ND FSTEN THE CSEMENT FSTENER..

28 28 MINTENNCE FITTING INSTRUCTIONS LURICTION INSTRUCTIONS IP NO IP NO IP NO IP NO IP NO IP NO IP NO GENERLLY all parts of a building have to be looked after and maintained from time to time. This of course also applies for fittings in windows and doors. How often fittings in windows and doors should be maintained depends to a large extent on how they are used, how often they are operated, and not least on the environment the fittings are exposed to. Corrosion may also be caused by other factors, such as corrosive liquids, air pollution etc. Special attention should be given to fittings used in windows and doors in urban and industrial areas or other areas with a high traffic intensity as well as coastal areas. Fittings in such environments should be checked and greased more often than fittings used in areas with less corrosive effects. HINGES ND FITTINGS should be lubricated when necessary, or at the minimum twice a year. SLIDING ELEMENTS S WELL S LL LURILS with sliding surfaces are to be kept clean and free from dust and dirt to ensure a smooth sliding function. Stearin wax or a clean lubricating film (but no oil and no grease!) can be applied onto the alluminium rails. ESPGNOLETTES ND OTHER LOCKING FITTINGS should be greased or lubricated with acid free grease or acid free oil on spray. The grease/oil should be applied into the mechanism box as well as on the joints of the side bolts, the roller bolts, or the mushroom head bolts while activating the mechanism repeatedly. Grease or lubricate when necessary or at the minimum twice a year. Continues...

29 2 MINTENNCE LURICTION INSTRUCTIONS RSS will sooner or later get some discoloration in a brownish tone depending on the environment in which it is placed. The original brass surface can be maintained by polishing from time to time. STINLESS STEEL can get some discoloration, although this rarely happens. Different chemical influences like acid fumes, contamination from wood preservation treatments, or air pollution may cause discoloration of the metal, sometimes to a reddish tone which could look like rust. Thin discoloration can be removed just by using common cleaner or polish. PINTED FITTINGS will from time to time need repainting. efore painting all parts should be cleaned carefully. When choosing type of paint and when applying the paint remember to follow the instructions from the paint manufacturer very carefully. When painting a wooden window in a house, it is a good idea also to paint the visible parts of the fittings (please note: No alurails nor sliding parts should ever be painted!). The painting of the fitting will minimize corrosion and add to the lifetime of the fitting. lways make sure that the proper function of a fitting is not affected by the painting. NODIZED LUMINIUM should be cleaned from time to time, depending on the surroundings in which it is placed. Cleaning of the surface with a cloth or sponge is recommended. Eventually a neutral solvent can be used. Emery cloth, steel wool, sodium carbonate, and other cleansers or abrasives containing alkalies or acid should never be used. ON THE WINDOW ND DOOR FCTORY SITE all fittings should be lubricated or greased before shipment. Hinges should be lubricated with acidfree oil while activating repeatedly, an acidfree grease can also be used. When using grease it should be applied directly onto the pin of the hinges. It may be necessary to dismantle the sash before greasing. Especially hinges with a brass pin should be greased. When mounting fittings, please make sure that the tools do not damage the original surface treatment. When original surface has been damaged make sure that remedial take place as soon as possible. WHEN IN DOUT PLESE CONTCT YOUR LOCL SUPPLIER OR /S J. PETERSENS ESLGFRIK.

30 30 FITTING ESPGNOLETTES INSTRUCTIONS IP HS LRGE PROGRMME OF ESPGNOLETTE OLTS WHICH SLIGHTLY MODIFIED CN E USED IN THE REHU NORDIC DESIGN PROFILE. EXMPLE IP NO.S RECEIVER IP NO HNDLE IP NO SK YOUR DELER OR CONTCT IP DIRECTLY FOR MORE INFORMTION.

31

32 /S J. PETERSENS ESLGFRIK JCO PETERSENSVEJ, DK-240 NIE TEL.: (+45) ipa@ipabeslag.dk Printed 03/2011

IPA FITTINGS FOR ALUPLAST NORD-LINE A/S J. PETERSENS BESLAGFABRIK JACOB PETERSENSVEJ 9, DK-9240 NIBE TEL: (+45)

IPA FITTINGS FOR ALUPLAST NORD-LINE A/S J. PETERSENS BESLAGFABRIK JACOB PETERSENSVEJ 9, DK-9240 NIBE TEL: (+45) IP FITTINGS FOR LUPLST NORD-LINE /S J. PETERSENS ESLGFRIK JCO PETERSENSVEJ 9, DK-9240 NIE TEL: (+4) 98 3 1 00 3 FITTINGS FOR LUPLST NORD-LINE Table of Contents Profile - luplast Nord-Line 4 FITTINGS IP

More information

IPA FITTINGS FOR VEKA DANLINE 70 A/S J. PETERSENS BESLAGFABRIK JACOB PETERSENSVEJ 9, DK-9240 NIBE TEL: (+45)

IPA FITTINGS FOR VEKA DANLINE 70 A/S J. PETERSENS BESLAGFABRIK JACOB PETERSENSVEJ 9, DK-9240 NIBE TEL: (+45) IP FITTINGS FOR VEK DNLINE 70 2012 /S J. PETERSENS ESLGFRIK JCO PETERSENSVEJ 9, DK-9240 NIE TEL: (+4) 98 3 1 00 3 FITTINGS FOR VEK DNLINE 70 Table of Contents PGE Profile - VEK Danline 70 4 Suggestion

More information

IPA FITTINGS FOR REHAU NORDIC

IPA FITTINGS FOR REHAU NORDIC IP FITTINGS FOR REHU NORDIC DESIGN PLUS 2017 /S J. PETERSENS BESLGFBRIK JCOB PETERSENSVEJ 9, DK-9240 NIBE TEL: (+45) 98 35 15 00 3 FITTINGS FOR REHU NORDIC DESIGN PLUS Table of contents PGE REHU Nordic

More information

IPA BESLAG FOR SCHÜCO ALU INSIDE NORDIC A/S J. PETERSENS BESLAGFABRIK JACOB PETERSENSVEJ 9, DK-9240 NIBE TEL: (+45)

IPA BESLAG FOR SCHÜCO ALU INSIDE NORDIC A/S J. PETERSENS BESLAGFABRIK JACOB PETERSENSVEJ 9, DK-9240 NIBE TEL: (+45) IPA BESLAG FOR SCHÜCO ALU INSIDE NORDIC 2015 A/S J. PETERSENS BESLAGFABRIK JACOB PETERSENSVEJ 9, DK-9240 NIBE TEL: (+45) 98 35 15 00 3 FITTINGS FOR SCHÜCO ALU INSIDE NORDIC Table of contents PAGE SCHÜCO

More information

IPA FITTINGS FOR SCHÜCO ALU INSIDE NORDIC A/S J. PETERSENS BESLAGFABRIK JACOB PETERSENSVEJ 9, DK-9240 NIBE TEL: (+45)

IPA FITTINGS FOR SCHÜCO ALU INSIDE NORDIC A/S J. PETERSENS BESLAGFABRIK JACOB PETERSENSVEJ 9, DK-9240 NIBE TEL: (+45) IPA FITTINGS FOR SCHÜCO ALU INSIDE NORDIC 2017 A/S J. PETERSENS BESLAGFABRIK JACOB PETERSENSVEJ 9, DK-9240 NIBE TEL: (+45) 98 35 15 00 3 FITTINGS FOR SCHÜCO ALU INSIDE NORDIC Table of contents PAGE SCHÜCO

More information

NORTH STAR 4-PANEL PATIO DOOR ASSEMBLY INSTRUCTIONS

NORTH STAR 4-PANEL PATIO DOOR ASSEMBLY INSTRUCTIONS 40684 Talbot Line, St. Thomas, Ont., N5P 3T Phone: (519) 637-7899 Toll Free: (800) 65-5701 Fax: (519) 637-3403 Web Site: www.northstarwindows.com NORTH STR 4-PNEL PTIO DOOR SSEMLY INSTRUCTIONS (JN/P-Dr04/4Panssy

More information

NORTH STAR 2-PANEL PATIO DOOR ASSEMBLY INSTRUCTIONS

NORTH STAR 2-PANEL PATIO DOOR ASSEMBLY INSTRUCTIONS 40684 Talbot Line, St. Thomas, Ont., N5P 3T2 Phone: (59) 637-7899 Toll Free: (800) 265-570 Fax: (59) 637-3403 Web Site: www.northstarwindows.com NORTH STR 2-PNEL PTIO DOOR SSEMBLY INSTRUCTIONS I:\PDssembly\2Panel\CovPg.doc

More information

* * 33/3549A CS 33/3549A. 2-Point Latch includes these additional parts. 1-Point Latch (LBL) Customer Service. Installation Instructions

* * 33/3549A CS 33/3549A. 2-Point Latch includes these additional parts. 1-Point Latch (LBL) Customer Service. Installation Instructions *23970726* 23970726 33/3549A CS 33/3549A Instlltion Instructions This instruction covers new instlltion of the 33/3549A conceled verticl device for luminum nd hollow metl doors. RF Also covered is the

More information

FOR DEVICES SOLD PRIOR TO

FOR DEVICES SOLD PRIOR TO 23970734 98/9949 CS 98/9949 FOR DEVICES SOLD PRIOR TO 8-10-16 This instruction covers new instlltion of the 98/9949 conceled verticl device for hollow metl nd luminum doors. RF Instlltion Instructions

More information

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS Multi Line 6 x8 255x193x203cm / 100 1 /2 x76 x80 Poly-Tex, Inc. PO Box 458 27725 Dnville Avenue Cstle Rock, MN 55010 We Site: www.poly-tex.com English - 69717 Hoy Greenhouse Service

More information

TUR DOORS SHOWER DOORS

TUR DOORS SHOWER DOORS TUR DOORS SHOWER DOORS INSTALLATION INSTRUCTIONS TUB DOORS: LBTDB6062 SHOWER DOORS: LBSDB4876 LBSDB6076 VERSION: 3.2 PREPARATION FOR INSTALLATION TUB DOORS SHOWER DOORS PREPARATION FOR INSTALLATION READ

More information

Multi-Point Astragal Prehanger Installation Instructions

Multi-Point Astragal Prehanger Installation Instructions Multi-Point Astrgl Prehnger Instlltion Instructions 8817 West Mrket Street Colfx, NC 27235 800.334.2006 www.endurproducts.com Tools Required: Endur Router Templte (or equivlent) Router with 5/8" dimeter

More information

RETRACTABLE SCREEN ASSEMBLY AND INSTALLATION INSTRUCTIONS. SINGLE OUTSWING (Retro) / (Full-Size) STEP 1: REVIEW & CHECK FIG.

RETRACTABLE SCREEN ASSEMBLY AND INSTALLATION INSTRUCTIONS. SINGLE OUTSWING (Retro) / (Full-Size) STEP 1: REVIEW & CHECK FIG. STEP 1: REVIEW & CHECK ) CONFIRM DOOR HEIGHT & WIDTH You have purchased a SINGLE Retractable Screen for an INSWING door. HEIGHT: This unit is available in two sizes: Retro and Full-Size. Please make sure

More information

670 Freestyle/Style Door with In-Line Panel

670 Freestyle/Style Door with In-Line Panel M 670 Freestyle/Style oor with In-Line Pnel Style Series Option Metl HK87 Slide MGNETIC PULL HNLE KIT with Mgnet Vinyl 083 JM E 989 MGNETIC OOR STOP N H900 PN HE SCREW C (CUH or MG) 781 HEER 716 HEER /

More information

MODEL 351 POWERGLIDE SERIES INSTRUCTIONS FOR INSTALLING SARGENT DOOR CLOSERS WITH "H" HOLDER ARMS

MODEL 351 POWERGLIDE SERIES INSTRUCTIONS FOR INSTALLING SARGENT DOOR CLOSERS WITH H HOLDER ARMS MODEL POWERGLIDE SERIES INSTRUTIONS FOR INSTLLING SRGENT LOSERS WITH "H" HOLDER S SERIES NON SIZED DJUSTLE SIZES THRU 6 UTION: FILURE TO INSTLL OR DJUST PROPERLY MY RESULT IN INJURY OR DMGE. FOR SSISTNE,

More information

Series Door with In-Line Panel (GIH / AHD)

Series Door with In-Line Panel (GIH / AHD) 600 7000 Series oor with In-Line Pnel (GIH / H) H900 P H 083 JM C 781 HR 716 HR / SILL ISRT H900 P H F H170 MGTIC STRIP H900 P H 083 JM H5195 STTIG LOCK VRTICL VIYL GLZIG X Y Z HORIZOTL VIYL GLZIG FRM

More information

Ultimate Flip Lever Astragal Prehanger Installation Instructions

Ultimate Flip Lever Astragal Prehanger Installation Instructions Ultimte Flip Lever Astrgl Prehnger Instlltion Instructions Tools Required: Flthed Screwdriver Shers Phillips Screwdriver Tpe Mesure Kit Includes: Full Astrgl Full Length Trim Strip Screw Pck Field Pck

More information

CANOPY SYSTEMS PAGE 1 OF 14

CANOPY SYSTEMS PAGE 1 OF 14 NOPY SYSTEMS PGE 1 OF 1 SY 092 I N S T L L T I O N I N S T R U T I O N S RED REFULLY! minimum of of two persons are required to install canopies. Do not step on base shelves... to avoid damage:. Do not

More information

Fitting & User Instructions

Fitting & User Instructions Issue 03 Alexnder Universl Furniture Risers Note: These frmes require the ddition of n ttchment. (See pges 4 - ) Bse Frme Mrk Bse Frme Mrk Fitting & User Instructions These instructions pply to the rising

More information

Canopy Bed Frame. Date: 8 Jun 15 www. potterybarn.com Page 1 of 12 Rev:

Canopy Bed Frame. Date: 8 Jun 15 www. potterybarn.com Page 1 of 12 Rev: Cnopy Bed Frme Dte: 8 un 15 www. potterybrn.com Pge 1 of 12 Importnt Sfety Instructions: WARNIN: Do not llow children to climb on, pull on, or hng from cnopy. Filure to follow these instructions cn result

More information

463-GP. Swing Door. Technical Assistance is available Monday - Friday, 8:00 a.m. - 5:00 p.m. (Central Time) (Toll Free) 463-GP 5/06

463-GP. Swing Door. Technical Assistance is available Monday - Friday, 8:00 a.m. - 5:00 p.m. (Central Time) (Toll Free) 463-GP 5/06 463-GP Swing Technical ssistance is available Monday - Friday, 8:00 a.m. - 5:00 p.m. (Central Time) 1-877-723-7190 (Toll Free) PRTS LIST FRME PCKGE KEY DESCRIPTION PRT QTY SILL 855 1 JM 942 2 E MGNETIC

More information

ASSEMBLY INSTRUCTIONS 5PC Storage Dining Set

ASSEMBLY INSTRUCTIONS 5PC Storage Dining Set ASSEMLY INSTRUTIONS 5P Storge Dining Set Sers Stock # 56170 VL Stock #07-2204 U S T O M E R S E R V I E I N F O R M AT I O N Victory Lnd Group, Inc 1350 Munger Rd rtlett, IL 60103 WE: http://www.victorylndgroup.com

More information

ET 51 EXTERIOR ROOF DRIP SIDE FINISH MOULDING INSTALLATION

ET 51 EXTERIOR ROOF DRIP SIDE FINISH MOULDING INSTALLATION EXTERIOR ROOF DRIP SIDE FINISH MOULDING 51 INSTALLATION The procedure descried elow is for the LH side. Use the sme procedure for oth the RH nd LH sides, unless otherwise specified. 1. INSTALL ROOF SIDE

More information

UPTOWN CANOPY FRAME T/F/Q

UPTOWN CANOPY FRAME T/F/Q UPTOWN CANOPY FRAM T/F/Q Dte: 30 Mr 16 www.pbteen.com Pge 1 of 12 mportnt Sfety nstructions: Plese red ll instructions crefully before ssembling. For your sfety, ssembly by two or more dults is strongly

More information

General Instructions 03HEL1010DDFW-V3. Please retain product label and instructions for future reference. 10x10 Helios Summer House

General Instructions 03HEL1010DDFW-V3. Please retain product label and instructions for future reference. 10x10 Helios Summer House Generl Instructions Plese retin product lel nd instructions for future reference 03HEL1010DDFW-V3 x2 All uilding s should e erected y two dults Winter = High Moisture = Expnsion Summer = Low Moisture =

More information

EAUZONE PLUS EPH - HINGED DOOR WITH HINGE PANEL FOR RECESS

EAUZONE PLUS EPH - HINGED DOOR WITH HINGE PANEL FOR RECESS EAUZONE PLUS EPH - HINGED DOOR WITH HINGE PANEL FOR RECESS INSTALLATION PARTS LIST BRITISH PATENT NO. 2470778 EPH MATKI PLC, CHURCHWARD ROAD, YATE, BRISTOL, BS37 5PL TELEPHONE:0454 32886 (AFTER SALES)

More information

620 Freestyle/Style Swing Door

620 Freestyle/Style Swing Door 620 Freestyle/Style Swing Door (CUH or MG) Style Series Option M HK87 MGNETIC PULL HNDLE KIT 989 MGNETIC DOOR STOP C 083 JM Metal Slide with Magnet H900 PN HED SCREW N Connector Screw J HTG6 PUSH / PULL

More information

* * 98/9949 CS 98/ Point Latch includes these additional parts. 1-Point Latch (LBL) Customer Service. Installation Instructions

* * 98/9949 CS 98/ Point Latch includes these additional parts. 1-Point Latch (LBL) Customer Service. Installation Instructions *23970734* 23970734 98/9949 CS 98/9949 Instlltion Instructions This instruction covers new instlltion of the 98/9949 conceled verticl device for hollow metl nd luminum doors. RF Also covered is the CS

More information

Steady Freddy Vinyl Gate REALLY. Important stuff to know about installing your WamBam gate

Steady Freddy Vinyl Gate REALLY. Important stuff to know about installing your WamBam gate Steady Freddy Vinyl Gate RELLY Important stuff to know about installing your Wamam gate. 1-877-778-5733 www.wambamfence.com CLEVER JOE Your Installation uddy This Gate is lso Designed to Fit the ig en

More information

Ultimate Trilennium Astragal Prehanger Installation Instructions

Ultimate Trilennium Astragal Prehanger Installation Instructions Ultimte Trilennium Astrgl Prehnger Instlltion Instructions Tools Required: Flthed Screwdriver Shers Phillips Screwdriver Power Drill with 1" Drill Bit Tpe Mesure 1" Spde Bit Kit Includes: Full Astrgl Full

More information

4 BAY Low Profile - SINGLE XL DISPLAY WALL MOUNT CABINET

4 BAY Low Profile - SINGLE XL DISPLAY WALL MOUNT CABINET D1/347Mxl SSEMLY INSTRUCTIONS 4 Y Low Profile - SINGLE XL DISPLY WLL MOUNT CINET TIP HZRD WRNING! Cabinet must be affixed to wall. For use with video monitors weighing 300 lbs (136kg) or less. Use with

More information

Aquauno Select MINUTES. (duration) FREQUENCY LED. OFF 8h AQUAUNO SELECT 5 MIN FREQUENCY. the timer is being programmed;

Aquauno Select MINUTES. (duration) FREQUENCY LED. OFF 8h AQUAUNO SELECT 5 MIN FREQUENCY. the timer is being programmed; Aquuno Select Pg. INSTALLATION. Attch the timer to cold wter tp, following these simple instructions. Do not instll the timer in pit or vlve ox, elow ground level or indoors. Do not use the timer with

More information

EAUZONE PLUS EPQ - QUINTESSE DESIGN WITH HINGED DOOR

EAUZONE PLUS EPQ - QUINTESSE DESIGN WITH HINGED DOOR EAUZONE PLUS EPQ - QUINTESSE DESIGN WITH HINGED DOOR INSTALLATION PARTS LIST BRITISH PATENT NO:470778 MATKI PLC, CHURCHWARD ROAD, YATE, BRISTOL, BS37 5PL TELEPHONE:0454 3886 (AFTER SALES) FAX:0454 388

More information

PRIME SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

PRIME SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS PRIME SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical drawings,

More information

LEXUS IS250/IS350 FRONT SPOILER Section I - Installation Preparation. Part Number: Section I - Installation Preparation.

LEXUS IS250/IS350 FRONT SPOILER Section I - Installation Preparation. Part Number: Section I - Installation Preparation. Section I - Instlltion Preprtion Prt Numer: 0854-53830 Section I - Instlltion Preprtion Kit Contents 3 Description Front spoiler Hrdwre g Instruction mnul Additionl Items Required For Instlltion Conflicts

More information

Frami transport hook Art. n models onward

Frami transport hook Art. n models onward 999281902-02/2015 en-g The Formwork Experts. Frmi trnsport hook rt. n 588494000 2009 models onwrd Originl Operting Instructions Plese retin for future reference Originl Operting Instructions Frmi trnsport

More information

4 BAY Low Profile WALL MOUNT CABINET

4 BAY Low Profile WALL MOUNT CABINET D1/347 SSEMLY INSTRUCTIONS 4 Y Low Profile WLL MOUNT CINET TIP HZRD WRNING! Cabinet must be affixed to wall. For use to prevent tipping in compliance with capacity of cabinet specified. Use with heavier

More information

RETRACTABLE SCREEN ASSEMBLY AND INSTALLATION INSTRUCTIONS. DOUBLE INSWING (Retro) / (Full-Size) FIG. 1A STEP 1: REVIEW & CHECK FIG.

RETRACTABLE SCREEN ASSEMBLY AND INSTALLATION INSTRUCTIONS. DOUBLE INSWING (Retro) / (Full-Size) FIG. 1A STEP 1: REVIEW & CHECK FIG. STEP 1: REVIEW & CHECK ) CONFIRM DOOR HEIGHT & WIDTH You have purchased a DOUBLE Retractable Screen for an INSWING door. HEIGHT: This unit is available in two sizes: Retro and Full-Size. Please make sure

More information

TECHNOLOGY IN MOTION MACO TILT AND TURN FITTINGS. MULTI POWER fully concealed fittings INSTALLATION INSTRUCTIONS

TECHNOLOGY IN MOTION MACO TILT AND TURN FITTINGS. MULTI POWER fully concealed fittings INSTALLATION INSTRUCTIONS TECHNOLOGY IN MOTION MACO multi-matic TILT AND TURN FITTINGS INSTALLATION INSTRUCTIONS Key Sash rebate height Sash rebate width Tilt-only window 50 kg Maximum sash weight 2 Contents Applications/processing

More information

INSTALLATION MANUAL. English Edition D75X ULTRA SHORT SERIES

INSTALLATION MANUAL. English Edition D75X ULTRA SHORT SERIES INSTLLTION MNUL English Edition D75X ULTR SHORT SERIES SFETY INSTRUCTION For your safety, please read the instruction before using the wall mount bracket. ny improper disposition caused by ignoring this

More information

846-GP. Neo-Angle Enclosure. Technical Assistance is available Monday - Friday 8:00 a.m. - 5:00 p.m. (Central Time) GP 12/05

846-GP. Neo-Angle Enclosure. Technical Assistance is available Monday - Friday 8:00 a.m. - 5:00 p.m. (Central Time) GP 12/05 846-GP Neo-ngle Enclosure Technical ssistance is available Monday - Friday 8:00 a.m. - 5:00 p.m. (Central Time) 1-877-723-7190 PRTS LIST FRME PCKGE KEY ESCRIPTION PRT QTY SILL 855 3 M 942 2 C HEER 101

More information

CABLE-RAIL A B B C C PARTS LIST DESCRIPTION SECTION C-C DIMENSION UNITS. Displayed: Millimeters Vista. 1:20 ASSEMBLY DRAWING Cable Railing

CABLE-RAIL A B B C C PARTS LIST DESCRIPTION SECTION C-C DIMENSION UNITS. Displayed: Millimeters Vista. 1:20 ASSEMBLY DRAWING Cable Railing PRODUCT FMILY DRWING # Displayed: Millimeters Vista :0 SSEMLY DRWING Cable Railing NOTES: () UILDING GENERL CONTRCTOR ND DESIGNER RE RESPONSILE FOR PROVIDING DEQUTE CKING ND CKING CONNECTION IN DECK STRUCTURE

More information

INSTALLATION & OPERATION INSTRUCTIONS LEVER HANDLE LOCKSETS.

INSTALLATION & OPERATION INSTRUCTIONS LEVER HANDLE LOCKSETS. INSTALLATION & OPERATION INSTRUCTIONS FOR LEVER HANDLE LOCKSETS 999-00333E_EN FOR BRINKS HOME SECURITY INTERIOR LOCKING & NON-LOCKING LEVER HANDLE LOCKSETS. FITS DOORS 1-3/8" (35 mm) TO 1-3/4" (45 mm)

More information

Assembly instructions. 6x4. Model GH1354A. 6x6. Model GH1357A. 6x8. Model GH1360A. 6x10. Walk-in Greenhouse. Model GH1363A

Assembly instructions. 6x4. Model GH1354A. 6x6. Model GH1357A. 6x8. Model GH1360A. 6x10. Walk-in Greenhouse. Model GH1363A ssembly instructions x Model GH x Model GH7 x8 Model GH0 x0 Model GH Walk-in Greenhouse Statement ear Customer! May we congratulate you on your new Greenhouse. We feel sure that by following the detailed

More information

blu The most efficient solution for manufacturing a flush casement window whilst maintaining the traditional image along with modern performance

blu The most efficient solution for manufacturing a flush casement window whilst maintaining the traditional image along with modern performance tritus flush casement window hardware FREE DELIVERIES 17.3 x 3mm Groove in the Sash 12 x 7mm Groove in the Frame ON ORDERS OVER 100 The most efficient solution for manufacturing a flush casement window

More information

NOTE THAT THE HANDLE IS BELOW THE LOCK BASE

NOTE THAT THE HANDLE IS BELOW THE LOCK BASE NOTE THT THE POSITION OF STOP IS LOCTED USING THE SINGLE HOLE S PLCEMENT GUIDE. NOTE THT THE HNDLE IS ELOW THE LOCK SE DETIL G SCLE.5. OF CHNGE DTE SIGN RELESED FOR PRODUCTION // RQ G SEE SHEET 3 FOR P/N

More information

New Milling Series. Metric type is added for all line up!! Tough edge GT chip breaker MSE45-SF MTE90-SF. Wiper insert is added for MSE45-SF type.

New Milling Series. Metric type is added for all line up!! Tough edge GT chip breaker MSE45-SF MTE90-SF. Wiper insert is added for MSE45-SF type. New Milling eries Metric type is dded for ll line up!! Octgonl MOF mill MOF ough edge G chip reker sy edge djustment M45F qure Insert~90 houlders New MO90 Wiper insert is dded for M45F type. sy edge djustment

More information

Assembly instructions

Assembly instructions Assembly instructions SF 55 / SF 55c SF 75 / SF 75c / SF 75H A B B C D Scope of delivery: Safety instructions: A. Top rail B. Vertical profile C. Floor rail D. Hinged panel, sliding panel Accessories pack

More information

Kitchen Island IMPORTANT Carefully remove all the parts from the carton and place them individually on a soft cloth to prevent scratches o

Kitchen Island IMPORTANT Carefully remove all the parts from the carton and place them individually on a soft cloth to prevent scratches o 88 5170 943 Kitchen Island IMPORTANT Carefully remove all the parts from the carton and place them individually on a soft cloth to prevent scratches or other damage. Carefully and strictly follow these

More information

* * 98/9949WDC. 1-Point Latch (LBL) 2-Point Latch includes these additional parts. Customer Service

* * 98/9949WDC. 1-Point Latch (LBL) 2-Point Latch includes these additional parts. Customer Service *24017501* 24017501 Coneled Vertil Devie for Wood Doors 98/9949WDC Instlltion Instrutions 1-Point Lth (LBL) 2-Point Lth inludes these dditionl prts NOTE: If door does not hve utout for ling inside lok

More information

GENERAL NOTES 1600 SYSTEM NOTES STRUCTURAL SEAL NOTES 1 - HANDLING, STORING AND PROTECTING ALUMINUM MATERIAL. 2 - GENERAL RULES

GENERAL NOTES 1600 SYSTEM NOTES STRUCTURAL SEAL NOTES 1 - HANDLING, STORING AND PROTECTING ALUMINUM MATERIAL. 2 - GENERAL RULES GENERL NOTES 162-971 1 OF 12 THESE INSTLLTION INSTRUCTIONS RE SUPPLEMENT TO THE PPROVED SHOP DRWINGS. USE IN CONJUNCTION WITH THOSE DRWINGS. 1 - HNDLING, STORING ND PROTECTING LUMINUM MTERIL. THE FOLLOWING

More information

DICTATOR RTS Tube Door Closer

DICTATOR RTS Tube Door Closer Tube Door Closer RTS v long DICTATOR RTS Tube Door Closer The "Invisible" Door Closer The DICTATOR RTS tube door closer is built into the door and therefore is as good as invisible. The joint can only

More information

Ultimate Push Button Astragal Prehanger Installation Instructions

Ultimate Push Button Astragal Prehanger Installation Instructions Ultimte Push Button Astrgl Prehnger Instlltion Instructions Tools Required: Flthed Screwdriver Shers Phillips Screwdriver Power Drill with 1" Drill Bit Tpe Mesure Kit Includes: Full Astrgl Full Length

More information

CHAPTER 11 3/4" Box (Finger) Joints

CHAPTER 11 3/4 Box (Finger) Joints 53 RTJ400 OPERTION CHPTER 11 3/4" ox (Finger) Joints IMPORTNT SFETY NOTE efore using your Leigh RTJ400 you must have completed the preparatory steps listed in the previous pages, including reading the

More information

Tubing Spacers. Backing Plate. a a. a a. a a. a a. a a. a a. a a. a a. a a. a a. a a. a a. a a. a a. a a. a a. a a a. a a. a a

Tubing Spacers. Backing Plate. a a. a a. a a. a a. a a. a a. a a. a a. a a. a a. a a. a a. a a. a a. a a. a a. a a a. a a. a a Grnd Slm Instlltion Instructions TACO Metls Inc., 98 NE 179th Street Mimi, Florid 33162 hndyhnk@tcomrine.com tcomrine.com This Box Contins: 1- Port side Grnd Slm 1- Strbord side Grnd Slm 4-5/16 x 1 stinless

More information

6 BAY AV CREDENZA WITH DUAL DISPLAY MOUNT

6 BAY AV CREDENZA WITH DUAL DISPLAY MOUNT D2/367M2 SSEMLY INSTRUCTIONS 6 Y V CREDENZ WITH DUL DISPLY MOUNT TIP HZRD WRNING! For use with video monitors weighing 175lbs (80kg) or less. Use with heavier televisions may result in instability causing

More information

B. Side Panel. E. Middle Panel 1 pc. 1 pc. 1 pc. S. Side Rack. 1 pc. T. Base Rack. U. Pipe 3 pcs. M6x35 Head Cap Bolt 14 pcs.

B. Side Panel. E. Middle Panel 1 pc. 1 pc. 1 pc. S. Side Rack. 1 pc. T. Base Rack. U. Pipe 3 pcs. M6x35 Head Cap Bolt 14 pcs. IMPORTANT 88 5089 95C Kitchen Cart Carefully remove all the parts from the carton and place them individually on a soft cloth to prevent scratches or other damage. Carefully and strictly follow these assembly

More information

Brio. Weatherfold 5c 80. Codes B WC 4-80 S H SS. Sets all sets shown with hinge type H except BW2L/R-80SR. No finishes shown. Brio Weatherfold 5c

Brio. Weatherfold 5c 80. Codes B WC 4-80 S H SS. Sets all sets shown with hinge type H except BW2L/R-80SR. No finishes shown. Brio Weatherfold 5c rio odes INSTW1 RV - UG 17 Weatherfold 5c 80 rio ustralia P: +1 2 8718718 W: brio.com.au : brio.sales@allegion.com rio UK P: +44 191 2291224 W: briouk.com : brio.sales.uk@allegion.com rio US P: +1 585

More information

001CK CK0012 FR-001CK0013 FR EN English

001CK CK0012 FR-001CK0013 FR EN English AUDIO ENTRY KIT FA00959EN 001DC00AC 001DC0EARY 7 10 001CS1PLCO INSTALLATION MANUAL 001CK0009 001CK001 FR001CK0013 FR EN English Generl Notes A Red the instructions crefully before beginning the instlltion

More information

CORNERVIEW / FRENCH CORNER

CORNERVIEW / FRENCH CORNER CORNERVIEW / FRENCH CORNER SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date

More information

TP Series - Triple PV Top of Pole Solar LED Lighting System

TP Series - Triple PV Top of Pole Solar LED Lighting System TP Series - Triple PV Top of Pole Solr LED Lighting System Instlltion Mnul MKTG-TP34-02-EN-1113 Instlltion Mnul TP Series Importnt Notes nd Wrnings This instlltion nd instruction mnul provides instlltion

More information

Radiant systems 0801EN March 2016 Radiant plasterboard ceiling and/or floor system ISO /7

Radiant systems 0801EN March 2016 Radiant plasterboard ceiling and/or floor system ISO /7 RADIANT CEILING SYSTEM Description is rdint ceiling/wll system relized with 600x1200 mm EPS200 preformed pnels coted with 0,3 mm luminium thermo-conductor sheets, where the plstic pipe with n externl Ø

More information

W6 series greenhouse

W6 series greenhouse W series greenhouse ssembly instructions Model W0 Model W07 Model W0 Model W Model W Walk-in Greenhouse Statement Dear Customer! May we congratulate you on your new Greenhouse. We feel sure that by following

More information

3 BAY AV CREDENZA WITH SINGLE DISPLAY MOUNT

3 BAY AV CREDENZA WITH SINGLE DISPLAY MOUNT D2/337M1 SSEMLY INSTRUCTIONS 3 Y V CREDENZ WITH SINGLE DISPLY MOUNT TIP HZRD WRNING! For use with video monitors weighing 175lbs (80kg) or less. Use with heavier televisions may result in instability causing

More information

MS25 OPERATION MANUAL

MS25 OPERATION MANUAL SAFETY INSTRUCTIONS SPECIFICATIONS OPERATING INSTRUCTIONS MAINTENANCE ADJUSTMENTS REPLACEMENT OF PARTS MS25 DIAGRAM MS25 PARTS LIST MS25 OPERATION MANUAL SAFETY INSTRUCTIONS Please read these instructions

More information

AQUA ULTRA SHOWER DOOR & TUB DOOR INSTALLATION INSTRUCTIONS

AQUA ULTRA SHOWER DOOR & TUB DOOR INSTALLATION INSTRUCTIONS AQUA ULTRA SHOWER DOOR & TUB DOOR INSTALLATION INSTRUCTIONS IMPORTANT DreamLine TM reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical

More information

Jiminy Picket Vinyl Gate REALLY. Important stuff to know about installing your WamBam gate

Jiminy Picket Vinyl Gate REALLY. Important stuff to know about installing your WamBam gate Jiminy Picket Vinyl Gate RELLY Important stuff to know about installing your Wamam gate. 1-877-778-5733 www.wambamfence.com CLEVER JOE Your Installation uddy November 2014 Reality Check 1 - Read Over Fence

More information

PARAGON BATH SHOWER DOOR/ BATH TUB SCREEN INSTALLATION INSTRUCTIONS. DR-584b

PARAGON BATH SHOWER DOOR/ BATH TUB SCREEN INSTALLATION INSTRUCTIONS. DR-584b PARAGON BATH SHOWER DOOR/ BATH TUB SCREEN INSTALLATION INSTRUCTIONS DR-584b Please read these instructions carefully before installing. If you have any questions regarding installation, please call our

More information

Barnside Pantry IMPORTANT NOTE Carefully remove all the parts from the carton and put them individually on a soft cloth to prevent scratch

Barnside Pantry IMPORTANT NOTE Carefully remove all the parts from the carton and put them individually on a soft cloth to prevent scratch 88 5516 653 Barnside Pantry IMPORTANT NOTE Carefully remove all the parts from the carton and put them individually on a soft cloth to prevent scratches or other damage occurring to the parts. We have

More information

Yard & Pool Vinyl Gate REALLY. Important stuff to know about installing your WamBam gate Ver 1, February 2014

Yard & Pool Vinyl Gate REALLY. Important stuff to know about installing your WamBam gate Ver 1, February 2014 Yard & Pool Vinyl Gate RELLY Important stuff to know about installing your Wamam gate. Ver 1, February 2014 1-877-778-5733 www.wambamfence.com Reality Check 1 - Read Over Fence Instructions First Your

More information

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution Incrementl encoders Solid shft with clmping or synchro flnge 0 5000 pulses per revolution ExEIL580 - solid shft Fetures Size mm Precise opticl sensing Output signl level TTL or HTL Clmping or synchro flnge

More information

C. Side Panel 1 pc. B. Side Panel. 1 pc. J2. Shelf. 4 pcs. Adjustable Pin 24 pcs. (+1 extra) M3.5x16 Wood Screw 20 pcs. (+1 extra) 2 pcs.

C. Side Panel 1 pc. B. Side Panel. 1 pc. J2. Shelf. 4 pcs. Adjustable Pin 24 pcs. (+1 extra) M3.5x16 Wood Screw 20 pcs. (+1 extra) 2 pcs. IMPORTANT 20 05180 0307 Hutch Carefully remove all the parts from the carton and place them individually on a soft cloth to prevent scratches or other damage. Carefully and strictly follow these assembly

More information

ARK CHEVRON INSTALLATION GUIDE

ARK CHEVRON INSTALLATION GUIDE ARK CHEVRON INSTALLATION GUIDE THANK YOU FOR YOUR PURCHASE OF DUCHÂTEAU WALL COVERINGS. We recommend you hire n experienced finish crpenter or wood flooring instller to chieve qulity results with ll DuChâteu

More information

Weatherfold 4s 50 & 100 Brio Australia P: W: brio.com.au

Weatherfold 4s 50 & 100 Brio Australia P: W: brio.com.au Codes INSTBWS2 REV J - MAR 2017 Weatherfold 4s 50 & 100 Brio Australia P: +61 2 87186718 W: brio.com.au E: brio.sales@allegion.com Brio UK P: +44 191 2291224 W: briouk.com E: brio.sales.uk@allegion.com

More information

4 BAY Low Profile-Dual Displays WALL MOUNT CABINET

4 BAY Low Profile-Dual Displays WALL MOUNT CABINET D1/347M2 SSEMLY INSTRUTIONS 4 Y Low Profile-Dual Displays WLL MOUNT INET TIP HZRD WRNING! abinet must be affixed to wall. For use with video monitors weighing 175lbs (80kg) or less. Use with heavier televisions

More information

Packing List MODEL TEL-IAL-481 For Inactive Leaf TRIDENT double door

Packing List MODEL TEL-IAL-481 For Inactive Leaf TRIDENT double door Items: SECURITECH GROUP, INC. MP uxiliary POLICE LOCK Packing List MODEL TEL-IL-481 For Inactive Leaf TRIDENT double door Items with * are pre-installed or assembled Fasteners: Part# Qty Name Description/Usage

More information

Cottage Picket Gate. 6 in in in in

Cottage Picket Gate. 6 in in in in S S E M LY I N S T R U T I O N S www.newenglandarbors.com ottage Picket Gate 1.875 in 6 in 43.75 in 22.5 in 2 48.5 in Please read through before starting assembly. heck ox for These ontents (1 ox) In the

More information

Peeping Tom Vinyl Gate REALLY. Important stuff to know about installing your WamBam gate

Peeping Tom Vinyl Gate REALLY. Important stuff to know about installing your WamBam gate Peeping Tom Vinyl Gate RELLY Important stuff to know about installing your Wamam gate. 1-877-778-5733 www.wambamfence.com CLEVER JOE Your Installation uddy January 2015 Reality Check 1 - Read Over Fence

More information

Installation & User Manual

Installation & User Manual 0-900 Tool-less Blade Guide System * Retrofit Kit For RIKON 4 Bandsaws 0-4 & 0-5 * PTENT PENDING Installation & User Manual Record the date of purchase in your manual for future reference. Date of purchase:

More information

Weatherfold 4s 50, 75 & 100

Weatherfold 4s 50, 75 & 100 Codes Weatherfold 4s 50, 75 & 100 Brio Australia P: +61 2 87186718 W: brio.com.au E: sales@brio.com.au Brio RMD UK Ltd. P: +44 191 2291224 W: briouk.com E: sales@briouk.com INSTBWS1 REV D - NOV 2011 Brio

More information

Please Do Not Return Product to Store!

Please Do Not Return Product to Store! Instlltion Guide for ndersen Luminire Retrctble Insect Screen Door with Slidewy Insect Screen System Designed for 6 wide by 80 tll single hinged doors with suitble mounting surfce. For instlltion help

More information

Closet Wall Drawer Unit

Closet Wall Drawer Unit IMPORTANT 88 5531 752 Carefully remove all the parts from the carton and place them individually on a soft cloth to prevent scratches or other damage. Carefully and strictly follow these assembly instructions

More information

WETROOM WALK-IN AWL1500 AWL1200 AWL900 AWC850

WETROOM WALK-IN AWL1500 AWL1200 AWL900 AWC850 WETROOM WALK-IN AWL500 AWL00 AWL900 AWC850 INSTALLATION PARTS LIST MODEL: AWL500 AWL00 AWL 900 MODEL: AWL500 + AWC850 AWL00 + AWC850 AWL 900 + AWC850 03 AF /6 IMPORTANT Before disposing of crton nd/or

More information

063-GP. Swing Door with In-Line Panel

063-GP. Swing Door with In-Line Panel 063-GP Swing with In-Line Technical ssistance is available Monday - Friday, 8:00 a.m. - 5:00 p.m. (entral Time) 1-877-723-7190 (Toll Free) PRTS LIST FRME PGE EY ESRIPTION PRT QTY SILL 855 1 JM 942 2 HEER

More information

ESSENCE. Shower / Tub Door Installaion Instructions

ESSENCE. Shower / Tub Door Installaion Instructions ESSENCE Shower / Tub Door Installaion Instructions IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical drawings,

More information

PROGRAMMING MANUAL MTMA/01 MTMV/01 FB00329-EN

PROGRAMMING MANUAL MTMA/01 MTMV/01 FB00329-EN RMMING MNUL MTM/01 MTMV/01 FB00329-EN Generl precutions Red the instructions crefully efore eginning the instlltion nd crry out the ctions s specified y the mnufcturer. The instlltion, progrmming, commissioning

More information

ROOF RACK INSTALLATION INSTRUCTIONS (FOR FITMENT TO EGR CANOPIES)

ROOF RACK INSTALLATION INSTRUCTIONS (FOR FITMENT TO EGR CANOPIES) INSTLLTION INSTRUCTIONS (FOR FITMENT TO EGR CNOPIES) FORD RNGER XL and XLT - (2006 Production Onwards) HOLDEN COLORDO - (2006 Production Onwards) MITSUISHI TRITON MN - (2009 Production Onwards) Installation

More information

GEI E INSTRUCTIONS M ULTI-CONTACT AUXILIARY RELAYS TYPE HFA53. GE Protection and Control 205 Great Valley Parkway Malvern, PA

GEI E INSTRUCTIONS M ULTI-CONTACT AUXILIARY RELAYS TYPE HFA53. GE Protection and Control 205 Great Valley Parkway Malvern, PA GEI-6871 9E INSTRUCTIONS M ULTI-CONTACT AUXILIARY RELAYS TYPE HFA53 GE Protection nd Control 205 Gret Vlley Prkwy Mlvern, PA 19355-1337 2 for Semi-flush Mounting (Front View) Connected Rely with Flnge

More information

ASY P.O. BOX 729 TERRELL, TEXAS / PAGE 1 OF 13 SAM

ASY P.O. BOX 729 TERRELL, TEXAS / PAGE 1 OF 13 SAM 203 Madix Inc., ll rights reserved ommon Parts 2 MXI GRI WIRE GRI SHELF WITH (GPWGS) MXI GRI FIXTURE PNEL (GPWFP) FIXTURE PNELS RE USE S EN SUPPORT. SHELF N E USE NYWHERE. MXI GRI REINFORMENT R 3 (GPR)

More information

PREASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS

PREASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS PROFILE SYSTEM PRE-ASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS s r ood gni d i l s dna gni t f i l r o f s t neme l e de l bme s s a - er P PREASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS MINITEC

More information

How to operate (folding)

How to operate (folding) How to operate (folding) LEFT HAND STACKING OUTWARD OPENING How to operate (folding) RIGHT HAND STACKING OUTWARD OPENING LOCK BOTH LEVER HANDLE AND FLAT HANDLE UTILISING THE D-HANDLE LOCATED ABOVE THE

More information

Chester - Solid Pine Desk

Chester - Solid Pine Desk Chester - Solid Pine Desk ssembly Instructions- Please keep for future reference 89/600 18/812 Dimensions Width - 120cm Depth - 50cm Height -,cm Important Please read these instructions fully before starting

More information

Storage Island. M3x25 Wood Screw for Side Panels 4 pcs. (+1 extra) Adjustable Pin 12 pcs. (+1 extra)

Storage Island. M3x25 Wood Screw for Side Panels 4 pcs. (+1 extra) Adjustable Pin 12 pcs. (+1 extra) IMPORTANT 88 5531 923 Storage Island Carefully remove all the parts from the carton and place them individually on a soft cloth to prevent scratches or other damage. Carefully and strictly follow these

More information

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution programmable (interpolated system)

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution programmable (interpolated system) Incrementl encoders Solid shft with clmping or synchro flnge 1 6556 pulses per revolution progrmmle (interpolted system) EIL580P - solid shft - OptoPulse Fetures Size mm Precise opticl sensing (interpolted)

More information

CURVED SLIDER SIDE ACCESS

CURVED SLIDER SIDE ACCESS KUDOS REFRESHING INNOVTION IN SHOWERS ORIGINL RNGE URVED SLIDER SIDE ESS Installation Instructions Please read these instructions before installing, as incorrect fitting will invalidate the guarantee.

More information

ModWood New Zealand Technical and Installation Guide

ModWood New Zealand Technical and Installation Guide PTO Pge 1 ModWood New Zelnd Technicl nd Instlltion Guide These guidelines should be red in conjunction with the New Zelnd Building Code (NZBC). Cluses tht pply to open, sltted decking nd blcony construction

More information

INFINITY-Z SHOWER DOOR / TUB DOOR INSTALLATION INSTRUCTION. MODEL #s 01-Chrome

INFINITY-Z SHOWER DOOR / TUB DOOR INSTALLATION INSTRUCTION. MODEL #s 01-Chrome INFINITY-Z SHOWER DOOR / TUB DOOR INSTALLATION INSTRUCTION IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical

More information

ELEGANCE SHOWER DOOR/ENCLOSURE INSTALLATION INSTRUCTIONS. Style A Style B Style C Style D

ELEGANCE SHOWER DOOR/ENCLOSURE INSTALLATION INSTRUCTIONS. Style A Style B Style C Style D ELEGANCE SHOWER DOOR/ENCLOSURE INSTALLATION INSTRUCTIONS IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical

More information

MACO ESPAGS ESPAGNOLETTES

MACO ESPAGS ESPAGNOLETTES MACO ESPAGS ESPAGNOLETTES Product Specification Guide Features Rapid-Fit shootbolt system. Single piece telescopic design. All screw fixings on one face. Reduced screw fixings. Central mushroom cams. Compression

More information

UNIDOOR X (STYLE L1)

UNIDOOR X (STYLE L1) UNIDOOR X (STYLE L) SHOWER DOOR & GLASS PANEL INSTALLATION INSTRUCTIONS IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date

More information