Tester G /G

Size: px
Start display at page:

Download "Tester G /G"

Transcription

1 Technical documentation Tester G /G for G-13 totalizer Operating instructions WP/ds Edition 1.0 BA.G190645_0567-GB CRANE National Rejectors, Inc. GmbH Zum Fruchthof 6 D Buxtehude Phone: +49 (0) Fax: +49 (0) info@nri.de Internet:

2 TABLE OF CONTENTS Table of contents 1 Introduction... 3 General information about these instructions... 3 General information about the testers... 3 Scope of delivery Construction and function Starting up Function test... 9 Function test of the 2 price totalizer... 9 Check price signal lines and blocking signal/reset signal line... 9 Reset using the blocking signal line... 9 Reset via the reset signal line Check coin return Function test of the timer Check price signal lines and reset signal lines Check price signal lines Check reset signal line Check blocking signal line Check coin return Function test of the TV totalizer Check price signal lines Check coin return Technical data CE Certification Index Glossary

3 INTRODUCTION 1 Introduction General information about these instructions To make it easier for you to navigate within these instructions, the following markings were used within the text: Safety instructions, which have to be taken note of in order to protect operators and equipment, have been written in bold and been given the pictogram. Special notes, which are to facilitate the use of the tester, have been written in italics and also been given a pictogram. Designation on the tester (switch/diode designations) taken over into the text are written in bold. For more detailed information which is not included within the scope of these instructions please refer to the following separate coin validator instructions: General description G General description G General information about the testers Tester G has a 5 digit display and tester G has a 4 digit display. As there is no other difference between the two testers in terms of function, both devices shall be described in one and the same manual. Both testers are used to check the function of the NRI G-13 totalizer. Instead of the vending machine, the tester receives the signals from the totalizer. If, when testing the totalizer, no signal is received by the tester, the line between the totalizer and the tester (vending machine) is defective. In addition, the tester is part of the device environment if the totalizer, when connected to a PC, is programmed and adjusted using the NRI software WinEMP, KunEMP, or ServEMP. The purpose of the tester is mainly as a supply of electricity for the totalizer. 3

4 INTRODUCTION Scope of delivery In addition to tester G or G the following items are included in delivery: 1 mains cable 1 earthing cable 1 extension cable to the distributor (16 contacts) 1 distributor letter of information with reference to NRI Homepage to download the appropriate operating instructions 4

5 CONSTRUCTION AND FUNCTION 2 Construction and function To easily place the tester at different angles, the tester has a movable stand (see Fig. 1a). If it is to be in a flat position and not at an angle, the stand can be positioned so that it is pointing up or to the front. The tester is then standing on four non-slip feet RÜ. SP. LÖ Front plate 2 Rear side 3 Stand Fig. 1a: Tester G The only difference between tester G and tester G shown here is that the first has a 4 digit display instead of a 5 digit display. 5

6 CONSTRUCTION AND FUNCTION The tester s operating elements are on the front plate: a mains switch and a number of toggle switches to check the function of the totalizer. Depending on the position of the switches, programming and functionality of the totalizer, a number of pilot lamps assigned to the different functions, light up. The money inserted into the coin validator is displayed on the 5 digit/4 digit display. (See Fig. 1b) RÜ. SP. LÖ. 3 Fig. 1b: Operating elements of tester G Mains switch 2 Display 3 Toggle switch SP. (common inhibit/delete price) 4 Toggle switch LÖ. (delete price) 5 Pilot lamp 1 (1 st price) 6 Pilot lamp 2 (2 nd price) 7 Pilot lamp RÜ. (Return credit) The only difference between tester G and tester G shown here is that the first has a 4 digit display instead of a 5 digit display. 6

7 CONSTRUCTION AND FUNCTION On the back of the device a 16 contact interface to connect the totalizer, an earth and a mains connection is fitted (see Fig. 1c) Fig. 1c: Interfaces of tester G and G Mains connection 2 Earth connection 3 Totalizer connection (16 contacts) 7

8 STARTING UP 3 Starting up The testers can only be used to test G-13 totalizers. Do not connect any other coin validators or totalizers to the tester. Only use the connecting cables included in delivery. Non-compliance with these instructions can cause the failure of the system and damage the equipment. To connect the totalizer to the tester: Ensure that the mains switch on the tester has been switched off. Connect the G-13 totalizer with the tester using the interfaces shown in Fig. 2, the enclosed band cable and if necessary the distributor Fig. 2: Interfaces of tester G and G Mains connection 2 Earth connection 3 Totalizer connection (16 contacts) Connect the tester to earth using the earth connection and the earthing cable (see Fig. 2). Connect the tester to the electricity supply using the mains connection and the mains cable (see Fig. 2). Switch the tester on using the mains switch. 8

9 FUNCTION TEST 2 PRICE TOTALIZER 4 Function test As the different models of the G-13 totalizer (2 price totalizer/timer/tv totalizer) have different functions and these are checked in different ways, the chapter Function test has been sub-divided into three sections. Function test of the 2 price totalizer The following paragraphs describe how to test the functions of the G-13 2 price totalizer. For details on how to operate the 2 price totalizer, please refer to the separate operating instructions for the coin validator. Check price signal lines and blocking signal/reset signal line In the case of the G-13 2 price totalizer, the price is totalled until the set price has been reached or exceeded. The respective price signal line is activated. If the sales process has been completed, the credit must be deleted using the blocking signal or the reset signal line. Using the tester you can check whether the price signal line is activated once the price has been reached. Reset using the blocking signal line SP. If the totalizer deletes the credit via the blocking signal line (standard), please ensure that toggle switch SP. is in the lower switch position. insert as many coins into the coin validator until the 1 st or 2 nd selling price set has been reached or exceeded. The credit is totalled and displayed. If the credit reaches the price and if the price signal line is activated, pilot lamp 1 (1 st price) or 2 (2 nd price) must light up. When the greater of the two set prices has been reached, both pilot lamps light up (1 and 2). SP. put toggle switch SP. into the upper position. The blocking signal line is activated. Pilot lamp 1 or 2 and the credit displayed must be deleted. 9

10 FUNCTION TEST 2 PRICE TOTALIZER Reset via the reset signal line SP. If the totalizer deletes the credit via the reset signal line, please ensure that toggle switch SP. is in the lower switch position. insert as many coins into the coin validator until the 1 st or 2 nd selling price set has been reached or exceeded. The credit is totalled and displayed. If the credit reaches the price and if the price signal line is activated, pilot lamp 1 (1 st price) or 2 (2 nd price) must light up. When the greater of the two set prices has been reached, both pilot lamps light up (1 and 2). LÖ. Push toggle switch LÖ. up or down briefly. If the reset signal line is activated, pilot lamp 1 or 2 and the credit displayed must be deleted. Check coin return To check whether inserted coins are directed into the return area and not into the cash-box when the return lever is activated, simply operate the return lever on the totalizer. Pilot lamp RÜ. should light up. The coins inserted are directed into the return area. 10

11 FUNCTION TEST TIMER Function test of the timer The following paragraphs describe how to test the functions of the G-13 timer. For details on how to operate the timer, please refer to the separate operating instructions for the coin validator. Check price signal lines and reset signal lines The G-13 timer totals the credit and displays it on the display until the set start price has been reached or exceeded. The required function is triggered by the respective signal line. From now on the time equivalent to the credit is displayed and no longer the amount of credit even if additional coins are inserted. Once the last time unit has started, the second price signal line must be activated e.g. to emit an acoustic signal. Once the time unit has expired, the function is stopped and the credit is deleted. The vending machine can stop the current time using the reset signal line. Using the tester you can check whether the price signal lines are activated when the start price has been reached or when the last time unit has been activated and whether the time running is interrupted by operating the reset signal line. SP. Check price signal lines Please ensure that toggle switch SP. is in the lower switch position. Insert as many coins into the coin validator until the start price set has been reached or exceeded. The credit inserted is totalled and displayed initially. Once the credit reaches the start price and if the price signal line is activated, the time must be displayed and pilot lamp 1 must light up. Additional coins can be inserted into the coin validator. The displayed time changes accordingly. Once the last time unit is activated, the 2 nd price signal line must be activated independently and pilot lamp 2 must light up. If time has run out completely, the time display and both pilot lamps (1 and 2) must switch off. If inventory impulses have been programmed on the 2 nd signal line, they are shown by pilot lamp 2 flashing (for the function of the inventory impulses please refer to the separate operating instructions for the coin validator). 11

12 FUNCTION TEST TIMER SP. LÖ. Check reset signal line Please ensure that toggle switch SP. is in the lower switch position. Insert as many coins into the coin validator until the start price set has been reached or exceeded. The credit inserted is totalled and displayed initially. Once the credit reaches the start price and if the price signal line is activated, the time must be displayed, a dot behind the last digit of the display must flash and pilot lamp 1 must light up. Additional coins can be inserted into the coin validator. The displayed time changes accordingly. If the current function is to be interrupted now, push toggle switch LÖ. up or down briefly. If the reset signal line is activated, the time remaining must be interrupted. The dot behind the last digit on the display does not flash any more. Check blocking signal line To ensure that the coin validator does not accept any coins when common blocking has been activated, simply move toggle switch SP. into the upper switch position. Now the function common blocking has been activated. All coins inserted are directed into the return area. Check coin return To check whether inserted coins are directed into the return area and not into the cash-box when the return lever is activated, simply operate the return lever on the totalizer. Pilot lamp RÜ. should light up. The coins inserted are directed into the return area. 12

13 FUNCTION TEST TV TOTALIZER Function test of the TV totalizer The following paragraphs describe how to test the functions of the G-13 TV totalizer. For details on how to operate the TV totalizer, please refer to the separate operating instructions for the coin validator. Check price signal lines In the case of the G-13 TV totalizer, the credit is totalled and displayed until the set game price has been reached or exceeded and at least one output impulse has been transmitted to the tester (vending machine). The 1 st price signal line is activated and the credit reset automatically. A higher number of output signals can be assigned to two possible discount coins. Inventory impulses can have been programmed by the factory onto the 2 nd price signal line. SP. Using the tester you can check whether the price signal lines transmit output and inventory impulses: Please ensure that toggle switch SP. is in the lower switch position. Insert as many coins into the coin validator until the game price set has been reached or exceeded. The inserted credit is totalled and displayed by the tester. If the credit reaches the price and if at least one output impulse is transmitted by the price signal line, pilot lamp 1 must flash according to the impulse number. Pilot lamp 2 flashes if inventory impulses have been programmed on the 2 nd signal line. The number of inventory impulses transmitted depends on the value of the inserted coin type. The pilot lamp flashes according to this number. Check coin return To check whether inserted coins are directed into the return area and not into the cash-box when the return lever is activated, simply operate the return lever on the totalizer. Pilot lamp RÜ. should light up. The coins inserted are directed into the return area. 13

14 TECHNICAL DATA 5 Technical data Supply voltage 220 V CE Certification The CE certificate (CE = Communautés Européennes) confirms that our products comply with specified basic requirements of the applicable directive. The CE certificate is not a quality assurance certificate in terms of the quality expected by the manufacturer but only in terms of the quality demanded legally. It is a pure administrative certificate and is intended only as proof of compliance with the directives for the monitoring authorities and not directed at clients or final customers. Which directives were applied can be seen in the declaration of conformity. The manufacturer must keep this declaration available for the monitoring authorities only (for a minimum period of 10 years after the last product has been introduced to the market). However, upon request we can provide copies of this declaration for our customers. The following directives and their subsequent changes can be applied to our devices: 1. The EMV Directive (89/336/EEC) for devices which cause electromagnetic interference or are interfered with by such. 2. The Low Voltage Directive (73/23/EEC) for electrical operating means which are used with a nominal voltage of between 50 and 1000 V AC and V DC. 3. The CE Certificate Labelling Directive (93/68/EEC) Modification directive regarding the application and use of CE labels. 14

15 INDEX Index B Blocking signal line 9, 12, 16 C CE Certification 14 Coin properties 16 Coin return 10, 12, 13 Coin type 16 Common blocking 12 Construction, tester 5 D Discount coin 13, 16 Display 4 digit 3, 6 5 digit 3, 6 Distributor 4 E Earthing cable 4 Extension cable 4 F Function test 9 2 price totalizer 9 timer 11 TV totalizer 13 Function, tester 5 G General information 3 Glossary 16 I Interface 7 Introduction 3 Inventory impulses 11, 13, 16 M Mains cable 4 Mains switch 6 N Notes 3 O Operating elements 6 P Pilot lamp 6 Price signal line 9, 11, 13, 16 R Reset signal line 9, 10, 11, 12, 16 Return lever 10, 12, 13 Return line 16 S Safety instructions 3 Stand 5 Start price 11, 17 Starting up 8 T Technical data 14 Time unit 11, 17 Toggle switch 6 15

16 GLOSSARY Glossary Blocking signal line Coin properties Coin type Discount coin Inventory impulses Price signal line Reset signal line Return line Blocking signal line between the totalizer and the tester (vending machine), which is used to block coin acceptance. The blocking signal line can also take over the function of the reset signal line. Coin properties which are measured by the totalizer when a coin is inserted. These are material, thickness, volume, minting, diameter etc. One coin type includes all coins for which the coin properties agree. The TV totalizer can grant the customer a discount using two programmable coin types. To do this, the coin type is allocated an impulse number which is higher than that allocated to its value. If the coin amount is to be totalled for every coin inserted until the cash-box is emptied, so-called inventory impulses can be programmed on the 2 nd price signal line of the timer and TV totalizer. If the inventory function has been activated, the timer/tv totalizer transmits a certain number of inventory impulses which are totalled for every coin inserted of a certain coin type. The totalizer transmits a signal to the tester (vending machine) via the price signal line if a set selling price is reached or exceeded. This causes the vending machine to perform a certain function or deliver the merchandise. A reset signal is transmitted from the tester (vending machine) to the 2 price totalizer via the reset signal line. The totalizer interprets this as the vending operation having been completed and the credit is deleted. The function of the reset signal line can also be taken over by the blocking signal line. When the return lever on the totalizer is operated, a return signal is transmitted to the tester (vending machine) via the return line. 16

17 GLOSSARY Start price Time unit The price which must be achieved on the timer by inserting coins so that a specific function is triggered. For this the start price must be divisible by the programmable price for one time unit. A specific function which lasts for at least one time unit (programmable) can be bought at the timer for a programmable price. The entire duration is made up of a number of time units. 17

G-18.mft with vending machine control system for 1-5-chute machines

G-18.mft with vending machine control system for 1-5-chute machines Technical Documentation Electronic coin validator G-18.mft with vending machine control system for 1-5-chute machines Operating instructions 01.06 GS/Bur/WMe/ds Edition 1.1 BA.G18MFTAS-GB CRANE National

More information

G-13.mft MDB/S1 (from model /4 on) Electronic coin validator. Technical Documentation. Operating instructions CRANE

G-13.mft MDB/S1 (from model /4 on) Electronic coin validator. Technical Documentation. Operating instructions CRANE Technical Documentation Electronic coin validator G-13.mft MDB/S1 (from model /4 on) Operating instructions 12.05 Hns/ds Edition 1.2 BA.G13MFTMDBS1-GB CRANE National Rejectors, Inc. GmbH Zum Fruchthof

More information

Installation Guide. Coin changer Goe/Schn/KQu KA_c²_US_1-0

Installation Guide. Coin changer Goe/Schn/KQu KA_c²_US_1-0 Installation Guide Coin changer 02.12 Goe/Schn/KQu KA_c²_US_1-0 Crane Payment Solutions GmbH Zum Fruchthof 6 21614 Buxtehude Germany Web: info@craneps.com www.craneps.com Phone: +49 (0) 41 61-729-0 Fax:

More information

blue Coin changer Filling the change tubes What must be pointed out? Two pathes to full tubes Which one to take for my c 2?

blue Coin changer Filling the change tubes What must be pointed out? Two pathes to full tubes Which one to take for my c 2? blue Coin changer Filling the change tubes What must be pointed out? Two pathes to full tubes Which one to take for my c 2? The coin changer can be provided with change either by inserting the tube coins

More information

Coin changer. Technical Documentation. Short reference guide for starting up the spider system Schn/DVs/Roe Version 1.0 KA.

Coin changer. Technical Documentation. Short reference guide for starting up the spider system Schn/DVs/Roe Version 1.0 KA. Technical Documentation Coin changer Short reference guide for starting up the spider system 01.10 Schn/DVs/Roe Version 1.0 KA.CS-EN National Rejectors, Inc. GmbH Zum Fruchthof 6 D-1614 Buxtehude Phone:

More information

Manual Coin-Changer Series G-46

Manual Coin-Changer Series G-46 Technical Documentation Manual Coin-Changer Series G-46 01.02 ds/ Edition 4.4 HBG46GB CRANE National Rejectors, Inc. GmbH Zum Fruchthof 6 D-21614 Buxtehude Telefon: +49 (0)4161-729-0 Telefax: +49 (0)4161-729-115

More information

Digital Electronic Thermostat With RF

Digital Electronic Thermostat With RF RT300RF Manual Altech 005_89 06/05/2014 08:56 Page 1 Digital Electronic Thermostat With RF Instruction Manual Model No ALTHC015 RT300RF Manual Altech 005_89 06/05/2014 08:56 Page 2 2 ALTHC015 INSTRUCTION

More information

Optipay CC A-66 Coin Changer. Operation and Maintenance Manual (Revision 2) Includes configuration setup using a Palm Pilot Setting Module

Optipay CC A-66 Coin Changer. Operation and Maintenance Manual (Revision 2) Includes configuration setup using a Palm Pilot Setting Module Office: (800) 683-7248 Technical Support: (702) 651-3444 FAX: (702) 651-0214 E-Mail: optipaysupport@jcm-american.com Web-Site: www.jcm-american.com Optipay CC A-66 Coin Changer Operation and Maintenance

More information

UR3 Coin Validator rel. 1.3 UR3 MDB-Executive Coin Validator rel. 1.2 UR3 T Coin Validator rel User and Maintenance Manual

UR3 Coin Validator rel. 1.3 UR3 MDB-Executive Coin Validator rel. 1.2 UR3 T Coin Validator rel User and Maintenance Manual UR3 Coin Validator rel. 1.3 UR3 MDB-Executive Coin Validator rel. 1.2 UR3 T Coin Validator rel. 1.1 User and Maintenance Manual The information included in this manual may be modified without any prior

More information

WinEMP. Technical Documentation. Operating instructions for the G-40. The configuration and diagnostics program for NRI coin validators

WinEMP. Technical Documentation. Operating instructions for the G-40. The configuration and diagnostics program for NRI coin validators Technical Documentation The configuration and diagnostics program for NRI coin validators WinEMP Operating instructions for the G-40 12.08 GS/Eck/Roe Edition 3.3 BA.WINEMPG40-GB National Rejectors, Inc.

More information

DRAFT. Electronic coin validator. Technical Documentation. Operating instructions Hns/WP/Roe Version 0.2 BA.F2-EN

DRAFT. Electronic coin validator. Technical Documentation. Operating instructions Hns/WP/Roe Version 0.2 BA.F2-EN Technical Documentation 11.08 Hns/WP/Roe Version 0.2 BA.F2-EN Electronic coin validator Operating instructions DRAFT National Rejectors, Inc. GmbH Zum Fruchthof 6 D-21614 Buxtehude Phone: +49 (0)4161-729-0

More information

Digital Function Generator

Digital Function Generator Digital Function Generator 13654-99 PHYWE Systeme GmbH & Co. KG Robert-Bosch-Breite 10 37079 Göttingen Germany Tel. +49 (0) 551 604-0 Fax +49 (0) 551 604-107 E-mail info@phywe.de Operating Instructions

More information

MC108A-2 RF MULTI-COUPLER USER S GUIDE

MC108A-2 RF MULTI-COUPLER USER S GUIDE MC108A-2 RF MULTI-COUPLER USER S GUIDE Systems Engineering & Management Company 1430 Vantage Court Vista, California 92081 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS DOCUMENT CONSTITUTES

More information

Quick Start Instructions EMV-INspektor V2

Quick Start Instructions EMV-INspektor V2 Connecting the : The illustration below shows the connection diagram for the. Step 1: Before connecting the to the voltage supply, first establish the connection of the to the measuring clamp adapters.

More information

TPS 49 EDITION 2 JUNE 2009

TPS 49 EDITION 2 JUNE 2009 TPS 49 EDITION 2 JUNE 2009 Interim arrangements & guidance on the interpretation of IEC 61672 Sound Level Meters - Periodic Tests CONTENTS SECTION PAGE 1 Purpose and duration 2 2 Statement 2 3 Specific

More information

Wireless wall transmitter, 1-gang with inscription space, Wireless wall transmitter, 3-gang with inscription space

Wireless wall transmitter, 1-gang with inscription space, Wireless wall transmitter, 3-gang with inscription space Wireless wall transmitter, 1-gang with inscription space Order No. : 5331.. Wireless wall Order No. : 5333.. Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected

More information

Mounting instruction and operating manual. Access Point (UK) HmIP-HAP-UK

Mounting instruction and operating manual. Access Point (UK) HmIP-HAP-UK Mounting instruction and operating manual Access Point (UK) HmIP-HAP-UK Package contents Quantity Description 1 Homematic IP Access Point (UK) 1 Plug-in mains adapter 1 Network cable 2 Screws 2 Plugs 1

More information

A RANGE-STANDARD MODULAR VALIDATOR

A RANGE-STANDARD MODULAR VALIDATOR A RANGE-STANDARD MODULAR VALIDATOR Azkoyen 10042 UK 06-2004 1. INTRODUCTION AND DESCRIPTION OF COMPONENTS This Technical Manual contains the technical information related to the coin validators in the

More information

Seite 2 Standard-Empfänger. EN Operation Instructions

Seite 2 Standard-Empfänger. EN Operation Instructions sign lux DE Bedienungsanleitung Seite 2 Standard-Empfänger EN Operation Instructions Page 10 Standard receiver FR Mode d emploi Page 18 Récepteur standard NL Gebruiksaanwijzing Pagina 26 Standaard ontvanger

More information

Bosch Smart Home. Door/Window Contact Instruction Manual

Bosch Smart Home. Door/Window Contact Instruction Manual Bosch Smart Home Door/Window Contact Instruction Manual Start making your home smart! Please be sure to install the Bosch Smart Home Controller first. Please ensure that you have a Bosch Smart Home Controller

More information

DT-400W GB Rersion 1

DT-400W GB Rersion 1 DT-400W GB Rersion 1 Limited Warranty Sangean America, Inc. warrants this product to be free from defects in material and workmanship under normal use and conditions for a period of 90 (Ninety) days from

More information

CAMD Transition Sub Group FAQ IVDR Transitional provisions

CAMD Transition Sub Group FAQ IVDR Transitional provisions Disclaimer: CAMD Transition Sub Group FAQ IVDR Transitional provisions The information presented in this document is for the purpose of general information only and is not intended to represent legal advice

More information

Tokenote Training Guide For use with Hamilton Changers

Tokenote Training Guide For use with Hamilton Changers Hamilton Manufacturing Corp. 1026 Hamilton Dr. Holland, OH 43528 Phone: 419-867-4858/800-837-5561 Fax: 419-867-4857 www.hamiltonmfg.com Tokenote Training Guide For use with Hamilton Changers Document #101-0074

More information

INSTRUCTION MANUAL. IBRit - rf1 - usb PC - Station for wireless Data transmission. M e s s t e c h n i k. Messtechnik GmbH & Co.

INSTRUCTION MANUAL. IBRit - rf1 - usb PC - Station for wireless Data transmission. M e s s t e c h n i k. Messtechnik GmbH & Co. M e s s t e c h n i k INSTRUCTION MANUAL PC - Station for wireless Data transmission Document No. : D1F604 001 Version : April 2006 Copyright : IBR Messtechnik GmbH & Co. KG Contents 1. Introduction 1.1

More information

B-Tronic EasyControl EC5401B

B-Tronic EasyControl EC5401B B-Tronic EasyControl EC5401B en Assembly and Operating Instructions Wall/hand-held transmitter, 1-channel, bidirectional Important information for: Fitters / Electricians / Users Please forward accordingly!

More information

Heiland electronic GmbH TD / TD1 / TD2. B&W-Densitometers. USERS MANUAL Version 5

Heiland electronic GmbH TD / TD1 / TD2. B&W-Densitometers. USERS MANUAL Version 5 Heiland electronic GmbH TD / TD1 / TD2 B&W-Densitometers USERS MANUAL Version 5 2 Table of Contents 1. GENERAL INFORMATION...4 2. SAFETY REGULATIONS...5 3. AREA OF APPLICATIONS...5 4. INSTRUMENT DESCRIPTION...6

More information

Awning control system GFM001. Installation and Operating Instructions

Awning control system GFM001. Installation and Operating Instructions Geiger-Funk Sunshade controls Awning control system for 230V drives GFM001 Installation and Operating Instructions for pre-coded systems Table of Contents 1 Introduction...3 2 Safety instructions...3 3

More information

Radio System Strobe Wizard Plus Freemask

Radio System Strobe Wizard Plus Freemask Radio System Strobe Wizard Plus Freemask User manual Translation of the original German user manual Doc. No.: 900.0509.00 Version: 09/2017 Contents Information about this manual and about the manufacturer...

More information

Industriefunkuhren. Additional Technical Manual. for Board 7271 with Option FG7271/PPM (Output of Minute Pulses) ENGLISH. Version:

Industriefunkuhren. Additional Technical Manual. for Board 7271 with Option FG7271/PPM (Output of Minute Pulses) ENGLISH. Version: Industriefunkuhren Additional Technical Manual for Board 7271 with Option FG7271/PPM (Output of Minute Pulses) ENGLISH Version: 01.00-13.01.2009 Base Description NTP/SINEC H1 LAN Board Model 7271 Version:

More information

Installation And Programming Instructions For Profile Series With RF Technology

Installation And Programming Instructions For Profile Series With RF Technology Installation And Programming Instructions For Profile Series With RF Technology A7691A www.sargentlock.com 1 Table of Contents General Description Page 2 3 4 5 6 7 Installation of RF Technology Lock...1

More information

With Audible Detect Signal

With Audible Detect Signal T-100 SERIES SINGLE CHANNEL SHELF MOUNT DETECTOR Meets and exceeds NEMA TS 1 specification. Six front panel DIP switches provide: Seven levels of sensitivity plus off. Presence or Pulse mode. Four loop

More information

KNX radio wall-transmitter 1gang/2gang flat quicklink Order no.: 8565 x2 xx

KNX radio wall-transmitter 1gang/2gang flat quicklink Order no.: 8565 x2 xx KNX radio wall-transmitter 1gang/2gang flat quicklink KNX radio wall-transmitter 1gang/2gang flat quicklink Order no.: 8565 x2 xx KNX radio wall-transmitter 1gang/2gang flat solar quicklink Order no.:

More information

We at DigiTech are very proud of our products and back up each one we sell with the following warranty:

We at DigiTech are very proud of our products and back up each one we sell with the following warranty: Warranty We at DigiTech are very proud of our products and back up each one we sell with the following warranty: The warranty registration card must be mailed within ten days after purchase date to validate

More information

EC5401B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 1-channel, bidirectional

EC5401B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 1-channel, bidirectional B-Tronic EasyControl EC5401B en Assembly and Operating Instructions Wall/hand-held transmitter, 1-channel, bidirectional Important information for: Fitters / Electricians / Users Please forward accordingly!

More information

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W L L N N on error RUN 1 2 3 4 KNX EIB 1 1 1 1 Chapter 9: Dimming actuators/control units Chapter 9:Dimming actuators/control unitsart. no.6493xxas of 10/079.2Universal dimming actuators Universal dimming

More information

Radio Touch Order no.: 2880 xx. Operation and installation instructions. 1 Safety instructions. 2 Structure of the device (Figure 1) Radio Touch

Radio Touch Order no.: 2880 xx. Operation and installation instructions. 1 Safety instructions. 2 Structure of the device (Figure 1) Radio Touch Radio Touch Order no.: 2880 xx Operation and installation instructions 1 Safety instructions Electrical equipment must only be installed and assembled by a qualified electrician in accordance with the

More information

Multi Drop Bus 5-Tube Coin Changer. Series. Service Manual B D A C E SAT

Multi Drop Bus 5-Tube Coin Changer. Series. Service Manual B D A C E SAT Multi Drop Bus 5-Tube Coin Changer Series Service Manual DIS C/C A C E MOD B D SAT AUT 2 TABLE OF CONTENTS Page 1 Outline... 3 2 Product Model Names... 4 3 General Specifications... 5 4 Detailed Specifications...

More information

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) OWNER S MANUAL Model 5100F RF POWER AMPLIFIER 0.8 2.5 GHz, 25 Watts Ophir RF 5300 Beethoven Street Los Angeles, CA 90066

More information

Cable Identifying Generator LCI TX / LCI TX-440

Cable Identifying Generator LCI TX / LCI TX-440 Operation manual Cable Identifying Generator LCI TX / LCI TX-440 Mess- und Ortungstechnik Measuring and Locating Technologies Elektrizitätsnetze Power Networks Kommunikationsnetze Communication Networks

More information

Operation. 1 of 14. Serial number label

Operation. 1 of 14. Serial number label Telecody Keypad Transmitter (US) WARNING There is a possible risk of injury or death if safety instructions will not be observed. Please read and follow all instructions in this manual as well as the information

More information

HAWK5000 Operators Manual

HAWK5000 Operators Manual HAWK5000 Operators Manual Keison Products P.O. Box 2124, Chelmsford CM1 3UP, England Tel: +44 (0) 1245 600560 Fax: +44 (0) 1245 600030 Email: sales@keison.co.uk www.keison.co.uk KANE INTERNATIONAL LIMITED

More information

User Manual March 2008

User Manual March 2008 User Manual March 008 Motor Silent Gliss 900, 90, 90, 903 Motor Silent Gliss 9030, 903, 903, 9033 Usermanual Motors 90x_903x Page Copyright April 007 by Silent Gliss International Ltd., 3073 Gümligen/Berne

More information

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at Connevans.info Solutions to improve the quality of life Offering you choice Helping you choose This product may be purchased from Connevans Limited secure online store at www.deafequipment.co.uk DeafEquipment.co.uk

More information

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 UK-QB101575 / 29.05.2012 Brunata a/s is a Danish owned company. We have more than 90 years of experience within developing and producing

More information

Multifunction Devices CIM1, CIM12, CIM13, CIM14

Multifunction Devices CIM1, CIM12, CIM13, CIM14 Multifunction Devices CIM1, CIM12, CIM13, CIM14 1 Features Power supply AC and DC 24... 240 V, 16... 63 Hz 1 Change-over contact 16 A or emiconductor output 1.2 A AC or 4 A DC 8 timer functions: E, A,

More information

EPM 300(C) Installation Test Tool User Manual Template for OEM Manufacturers/First Marketer

EPM 300(C) Installation Test Tool User Manual Template for OEM Manufacturers/First Marketer Installation Test Tool User Manual Template for OEM Manufacturers/First Marketer EnOcean GmbH Kolpingring 18a 82041 Oberhaching Germany Phone +49.89.67 34 689-0 Fax +49.89.67 34 689-50 info@enocean.com

More information

Level Switch NRS 2-50 NRS Original Installation Instructions English

Level Switch NRS 2-50 NRS Original Installation Instructions English Level Switch NRS 2-50 NRS 2-51 EN English Original Installation Instructions 819179-03 1 Contents Important Notes Page Usage for the intended purpose...4 Function...4 Safety note...4 Directives and Standards

More information

Heat meter Q heat 5 US

Heat meter Q heat 5 US Heat meter Q heat 5 US Ultrasonic heat meter with ultrasonic measurement technology (runtime difference method) with IrDA interface and an interface for retrofitting external modules. Exact measurement

More information

Wireless Receiver E28Q Mounting and Operating Instructions (Original operating instructions)

Wireless Receiver E28Q Mounting and Operating Instructions (Original operating instructions) EN Wireless Receiver E28Q Wireless Receiver E28Q Mounting and Operating Instructions (Original operating instructions) Always read before initial operation! 28509900_E28Q_EN_2012-05-08.doc 1 / 12 1 Data

More information

WIRELESS Energy Monitor - Smart Meter

WIRELESS Energy Monitor - Smart Meter Energy saving made simple MONITOR CONTROL SAVE WIRELESS Energy Monitor - Smart Meter Monitors your electricity use and cost in real time Instruction Manual EW4500 IMPORTANT Please retain your Instruction

More information

Берг АБ Тел. (495) , факс (495) Initial operation and diagnosis

Берг АБ Тел. (495) , факс (495) Initial operation and diagnosis Axial/radial bearings with integral measuring system Initial operation and diagnosis Fitting and maintenance instructions MON 18 This technical publication has been produced with a great deal of care and

More information

RMO500 M I C R O O H M M E T E R

RMO500 M I C R O O H M M E T E R M I C R O O H M M E T E R Reference Manual IBEKO POWER AB Sweden 2 IBEKO POWER AB Manual Version:. MV.01 IBEKO POWER AB 2003 This Reference Manual is a publication of IBEKO POWER AB, 18 125 Lidingö, Sweden.

More information

Voltage Transient Emission Test

Voltage Transient Emission Test Manual For Operation AN 200 Series Voltage Transient Emission Test AN 200 AN 200B The AN 200 is used to evaluate automotive electrical and electronic components for conducted emissions of transients along

More information

Strain Gauge Measuring Amplifier BA 662

Strain Gauge Measuring Amplifier BA 662 Strain Gauge Measuring Amplifier BA 662 Original of the Manual Table of Contents 1. Safety precautions... 2 1.1. Field of application... 2 1.2. Installation... 2 1.3. Maintenance... 2 2. Function... 2

More information

Operating Instructions K-POWERgrip EWL Always on the safe site.

Operating Instructions K-POWERgrip EWL Always on the safe site. Operating Instructions K-POWERgrip EWL 4941. Always on the safe site. KaVo Elektrotechnisches Werk GmbH Wangener Straße 78 D-88299 Leutkirch A 1 User information...2 A 1.1 Meaning of the pictograms...2

More information

Merloni Elettrodomestici. Technical Fitting Manual FRIDGE. Language Issue/Edition Page GB /

Merloni Elettrodomestici. Technical Fitting Manual FRIDGE. Language Issue/Edition Page GB / GB 99-11-03/01 1-38 Index 1 CONFORMITY OF APPLIANCE 3 2 MAIN ASSEMBLY TYPES 3 2.1 Under worktop 3 2.2 Double door 10 2.3 Combined 14 2.4 Single door Fridge or single door Freezer 19 2.5 Combined free-standing

More information

Precipitation Monitor ,

Precipitation Monitor , THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for use 021197/11/09 Precipitation Monitor 5.4103.10.000, 5.4103.10.700 ADOLF THIES GmbH & Co. KG Hauptstraße

More information

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual INTRODUCTION: Congratulations on purchasing this temperature station with wireless 868 MHz transmission of outdoor temperature and display of indoor

More information

PWM LED strip dimmer module for the Velbus system

PWM LED strip dimmer module for the Velbus system VMB1LED PWM LED strip dimmer module for the Velbus system CONTENTS CONTENTS... 2 DESCRIPTION... 3 CHARACTERISTICS... 3 VELBUS CHARACTERISTICS... 5 OVERVIEW... 6 LED INDICATION... 7 USE WITHOUT VELBUS...

More information

GESTRA Steam Systems LRS English. Installation & Operating Instructions Conductivity Switch LRS 1-50

GESTRA Steam Systems LRS English. Installation & Operating Instructions Conductivity Switch LRS 1-50 GESTRA Steam Systems LRS 1-50 EN English Installation & Operating Instructions 819223-02 Conductivity Switch LRS 1-50 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety

More information

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual INTRODUCTION: Congratulations on purchasing this temperature station with wireless 868MHz transmission. It not only displays the indoor temperature

More information

RFTX-1 Installation Manual

RFTX-1 Installation Manual RFTX-1 Installation Manual complete control Universal Remote Control RFTX-1 Installation Manual 2009-2014 Universal Remote Control, Inc. The information in this Owner s Manual is copyright protected. No

More information

LITECOM. Special luminaires SEQUENCE infinity

LITECOM. Special luminaires SEQUENCE infinity LITECOM Special luminaires SEQUENCE infinity Legal information Copyright Copyright Zumtobel Lighting GmbH All rights reserved. Manufacturer Zumtobel Lighting GmbH Schweizerstrasse 30 6850 Dornbirn AUSTRIA

More information

Electrical devices may only be mounted and connected by electrically skilled persons.

Electrical devices may only be mounted and connected by electrically skilled persons. Order No. : 5490.. Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property damage possible.

More information

COFFEE LABORATORY WHITE STONE VA TEL

COFFEE LABORATORY WHITE STONE VA TEL 1. Technical specifications 4. Operating instructions: Octagon 200 Copyright 2015 by Endecotts Ltd. 21 1. Setting up Technical specifications SIEVE SHAKER MODEL: Octagon 200 General Information The sieve

More information

Operating Instructions PROFITEST H+E TECH. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) /3.

Operating Instructions PROFITEST H+E TECH. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) /3. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) 3-349-878-03 1/3.16 Opening the Instrument / Repairs The instrument may only be opened by authorized, trained personnel

More information

Economic and Social Council

Economic and Social Council United Nations Economic and Social Council ECE/TRANS/WP.29/GRE/2017/17 Distr.: General 7 August 2017 Original: English Economic Commission for Europe Inland Transport Committee World Forum for Harmonization

More information

DE EN FR IT ES RU PL DA NL NO SV

DE EN FR IT ES RU PL DA NL NO SV DE FR IT ES RU PL DA NL NO SV Table of Contents Instrument Set-up - - - - - - - - - - - - - - - - - - - - - - - Introduction- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Overview - - -

More information

MODEL AERONAUTICAL ASSOCIATION OF AUSTRALIA

MODEL AERONAUTICAL ASSOCIATION OF AUSTRALIA ASSOCIATION OF AUSTRALIA ISSUE 5-2002 APPROVED M.A.A.A. PRESIDENT Date: 12/08/2002 Table of Contents 1. Introduction 1 2. General 2 3. Frequency Control and Management 3 3.1 For 40kHz operation 3 3.2 For

More information

V21 Parts & Service Manual All V21 Identified Equipment REV A 10/2013 P/N: HV3 / CHAMELEON. V Programming HV3 / CHAMELEON P1-1

V21 Parts & Service Manual All V21 Identified Equipment REV A 10/2013 P/N: HV3 / CHAMELEON. V Programming HV3 / CHAMELEON P1-1 PROGRAMMING 12.4 PROGRAMMING SECTION HV3 / CHAMELEON V21 12.4 Programming HV3 / CHAMELEON P1-1 VEC 12.4 PROGRAMMING OPERATIONS NOTE: Some units may contain a European font display, in which case the symbol

More information

1 Safety instructions. 2 Device components. 3 Function. Radio Management Repeater. Operationsmanual

1 Safety instructions. 2 Device components. 3 Function. Radio Management Repeater. Operationsmanual Art.-No.: 100 FR Operationsmanual 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause damage to the

More information

Instruction manual. ZCO 2410 Conical mandrel tester

Instruction manual. ZCO 2410 Conical mandrel tester Zehntner GmbH Testing Instruments Gewerbestrasse 4 CH-4450 Sissach Switzerland Tel +41 (0)61 953 05 50 Fax +41 (0)61 953 05 51 zehntner@zehntner.com www.zehntner.com Instruction manual version 2.6 from

More information

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual INTRODUCTION: Congratulations on purchasing this fancy 868MHz Temperature Station which displays the time, indoor temperature and indoor humidity,

More information

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Giga-tronics GT-1050A Microwave Power Amplifier GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier Operation Manual

More information

EMC Test Report. Report Number: M030826

EMC Test Report. Report Number: M030826 Page 1 of 36 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EMC Test Report Report

More information

How to Operate the Testo 870 thermal imager

How to Operate the Testo 870 thermal imager How to Operate the Testo 870 thermal imager Content 1. Technical data testo 870-1 & 870-2 2. Technical overview (Fixed focus) 3. Interface/internal memory 4. Inserting the battery 5. Operation of the testo

More information

Robot e.do. Certifications, Service, Warranty. Rel Versions: 4 axes and 6 axes

Robot e.do. Certifications, Service, Warranty. Rel Versions: 4 axes and 6 axes Robot e.do Rel. 00 - Versions: 4 axes and 6 axes Certifications, Service, Warranty Directives and reference standards according to which the Robot has been certified. Terms, conditions to be fulfilled

More information

Series 3000 Model R-107A

Series 3000 Model R-107A Series 3000 Model R-107A DUAL TONE SENDER INSTRUCTION MANUAL Monroe Electronics 100 Housel Ave Lyndonville NY 14098 800-821-6001 585-765-2254 fax 585-765-9330 monroe-electronics.com Printed in USA Copyright

More information

Table of Contents. Makita LD050P 1

Table of Contents. Makita LD050P 1 Table of Contents EN Instrument Set-up - - - - - - - - - - - - - - - - - - - - - - - Introduction- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Overview - - - - - - - - - - - - - - - - -

More information

autotronic multitronic Radio transponder reader NB693N Installation and operation instructions

autotronic multitronic Radio transponder reader NB693N Installation and operation instructions WWW.FUHR.DE autotronic Radio transponder reader NB693N Installation and operation instructions These instructions are to be passed on by the fitter to the user. MBW23-GB/04.16-4 Inhalt 1 Applications...3

More information

f i r e - p a r t s. c o m

f i r e - p a r t s. c o m Model: CON 1001-1 INSTALLATION AND OPERATING INSTRUCTIONS SINGLE-FUNCTION WIRELESS REMOTE CONTROL SYSTEM FOR OPERATING VALVES WITH ON/OFF LATCHING SOLENOIDS IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION

More information

Motor 1- GENERAL DESCRIPTION

Motor 1- GENERAL DESCRIPTION 1- GENERAL DESCRIPTI TELECO AUTOMATI SRL - Via dell Artigianato, 16-31014 Colle Umberto (TV) ITALY TELEPHE: ++39.0438.388511 FAX: ++39.0438.388536 This document is the property of Teleco Automation Srl

More information

THE KENYA POWER AND LIGHTING CO. LTD. SPECIFICATIONS for IMPULSE VOLTAGE TEST EQUIPMENT

THE KENYA POWER AND LIGHTING CO. LTD. SPECIFICATIONS for IMPULSE VOLTAGE TEST EQUIPMENT THE KENYA POWER AND LIGHTING CO. LTD SPECIFICATIONS for IMPULSE VOLTAGE TEST EQUIPMENT NAME DESIGNATION SIGNATURE DATE Compiled by Ephantus Nyagah Ag. Senior Engineer Checked by Eng. Thagichu Kiiru Deputy

More information

1 Safety instructions. 2 Device components. Radio bus system. Radio socket outlet adapter for dimming Order No. : Operating instructions

1 Safety instructions. 2 Device components. Radio bus system. Radio socket outlet adapter for dimming Order No. : Operating instructions Order No. : 1185.. Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property damage possible.

More information

Operating instructions Fail-safe delay timer AZS About this document. Content

Operating instructions Fail-safe delay timer AZS About this document. Content 8 Appendix 8.1 Wiring example...4 8.2 Integral System Diagnostics (ISD)....5 9 EU Declaration of conformity Operating instructions.............pages 1 to 6 Original x.000 / 11.2017 / v.a. - 101126753-

More information

Operating Instructions

Operating Instructions Operating Instructions 5 Coin Validator with BDTA/BACTA Interface 08.15 Hns/GS/Roe BA_v2_eagle_parallel_EN_1-1 CPI Crane Payment Innovations GmbH Zum Fruchthof 6 21614 Buxtehude Germany Web: info@cranepi.com

More information

CBCT TM CIRCUIT BREAKER COIL TESTER

CBCT TM CIRCUIT BREAKER COIL TESTER CBCT TM CIRCUIT BREAKER COIL TESTER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 August 2010 Revision 1 SAFETY

More information

Model (1x12) Coax Multiplexers

Model (1x12) Coax Multiplexers Model 3000-524 4(1x12) Coax Multiplexers 904001110 Page 1 All technical data and specifications in this publication are subject to change without prior notice and do not represent a commitment on the part

More information

Contents. English 1. French 29. Spanish. FEATURES: The Temperature Station

Contents. English 1. French 29. Spanish. FEATURES: The Temperature Station Contents Language Page English 1 French 29 Spanish Topic Page Inventory of Contents 2 Features 3 Setting Up Battery Installation 7 Function keys 9 LCD Screen and Settings 11 Manual Settings 13 Viewing

More information

Nikon D7100 Camera Kit. -Checklist and Operations Manual-

Nikon D7100 Camera Kit. -Checklist and Operations Manual- Airborne Digital Reconnaissance System (ADRS) Nikon D7100 Camera Kit -Checklist and Operations Manual- V4.2 October 21, 2014 National Headquarters, Civil Air Patrol 2 1.0 Equipment Pre-Mission Check 1.1

More information

icash 15E, Version 2 Operating Manual

icash 15E, Version 2 Operating Manual icash 15E, Version 2 Operating Manual Questions and suggestions Do you have...... any questions or suggestions regarding this manual? Please contact the following address giving the order number of this

More information

Electrical devices may only be mounted and connected by electrically skilled persons.

Electrical devices may only be mounted and connected by electrically skilled persons. Art. No. : FM..1561.07.. Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property damage possible.

More information

ECM3 EARTH CONTINUITY RELAY

ECM3 EARTH CONTINUITY RELAY TECHNICAL DATASHEET ECM3 EARTH CONTINUITY RELAY Electrical Protection for Hard Rock Mines Application The ECM3 has been designed to provide earth continuity protection for cables containing pilot cores.

More information

Quick Start Guide. ELPRO 905U-L-T Wireless I/O Transmitter Unit. man_905u-l-t_quickstart_v1.9.doc

Quick Start Guide. ELPRO 905U-L-T Wireless I/O Transmitter Unit. man_905u-l-t_quickstart_v1.9.doc Quick Start Guide ELPRO 905U-L-T Wireless I/O Transmitter Unit man_905u-l-t_quickstart_v1.9.doc About this document This document is the and contains the following sections: Section Basic steps for using

More information

METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14

METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14 3-349-813-3 1/9.14 Insulation measurement per EN 61557-2/VDE 413, part 2 Test voltages: 5 V, 1 V, 25 V, 5 V and 1 V Analog display of measured values and limit values Intelligent filter precise and measurement-dependent

More information

Checklist for electromechanical and electronic active energy meters in accordance with the MID Directive (2004/22/EC)

Checklist for electromechanical and electronic active energy meters in accordance with the MID Directive (2004/22/EC) Checklist for electromechanical and electronic active energy meters in accordance with the MID Directive (2004/22/EC) Applicant: Instrument type: 1. General requirements NOTE: Definitions are based on

More information

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New) XR1 Rotor Earth Fault Relay (May 2007) Manual XR1 (Revision New) Woodward Manual XR1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided

More information

INSTRUCTIONS MODELS AVX-TFR-MELF TEST JIG FOR USE WITH AVTECH AVR-EBF6-B FORWARD RECOVERY TEST SYSTEMS SERIAL NUMBER:

INSTRUCTIONS MODELS AVX-TFR-MELF TEST JIG FOR USE WITH AVTECH AVR-EBF6-B FORWARD RECOVERY TEST SYSTEMS SERIAL NUMBER: A V T E C H E L E C T R O S Y S T E M S L T D. N A N O S E C O N D W A V E F O R M E L E C T R O N I C S S I N C E 1 9 7 5 P.O. BOX 265 OGDENSBURG, NY U.S.A. 13669-0265 TEL: 888-670-8729 (USA & Canada)

More information

Limit switch attachments DAPZ

Limit switch attachments DAPZ Type codes DAPZ SB M 250AC DR AR Type DAPZ Limit switch attachment Specification SB Sensor box Measuring principle I M Inductive Electrical, micro switch Operating voltage 25DC 30DC 250AC 8 V DC 30 V DC

More information

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Furnish and install automatic transfer switches (ATS) with number of poles, amperage, voltage, and withstand

More information