1 Page of 5 MODEL 5854 VXIbus UNIVERSAL POWER METER UNIVERSAL POWER MEASUREMENT Introducing the 5854 Universal Power Meter. The lastest member of the Giga-tronics family of innovative VXIbus microwave test and measurement solutions. Now, for the very first time, you can get NIST traceable, lab grade CW and peak power measurements quickly and accurately from a singleslot VXIbus module. POWER MEASUREMENTS INSTANTLY The Giga-tronics 5854 is te fastest VXI power meter available. Measurement speeds exceed 5 readings per second, and our exclusive Burst Mode captures more than 5, readings in the same tick of a clock. In fact, the 5854 is so fast you can measure the power level of many swept signals, giving you the capability of a scalar analyzer without the addtional cost. Because the 5854 supports the scpi command language the standard for VXI computer controlled testing. Think about what all this will do for your ATE productivity as well as for your company s bottom line. FAST, EASY PEAK POWER MEASUREMENT The 5854 is the only VXI meter that lets you measure peak power directly. And it s as simple as attaching a peak power sensor. There are no time-consuming, unreliable duty cycle corrections.view the pulsed signal s amplitude profile on a scope and see the exact power measurement point on the pulse. THE SECRET IS THE SENSORS The Giga-tronics 5854 Universal Power Meter delivers incredible performance by taking full advantage of the speed and dynamic range of diode sensors. Giga-tronics has solved the challenge that previously limited diode sensors to the square law region below - dbm by utilizing a builtin power sweep calibration system. The power sweep calibrator uses a 5 MHz amplitude controlled oscillator to step from -3 to + dbm in db increments. Each step is set using an internal thermistor the standard for linearity. You get thermistor linearity, plus diode speed and dynamic range, for measuring signals
2 Giga-tronics Model 5854 VXIbus Uniersal Power Meter Page of 5 accurately over a full 9 db power range. And for incredible versatility, we offer a full range of CW and Peak sensor tailored to your spsecific needs. Our sensors cover frequency ranges from MHz to 4 GHz with up to 9 db dynamic range.there are to 5 Watt high power sensors, too. Use our diode-based True RMS sensors to accurately measure quadrature modulated signals, intermodulation distortion power and db gain compression. Use our Low VSWR sensor for unequalled CW measurement accuracy. Or connect a Precision Return Loss Bridge and measure Return Loss or VSWR using only a single channel. TWO CHANNEL OPERATION The 5854 provides two channel operation, so you can see readings from both channels simultaneously. Use one channel for CW and the other for peak measurements, and see both readings at the same time. Or read one channel in db and the other in mw for measuring gain and output power simultaneously. With all you ve got to do, imagine the ti you ll save. Accuracy Audit Assume the power meter is being used to measure the output power at GHz from a source with a VSWR=.5:. Displayed power level is -5 dbm. Noise and mismatch calculations assume Standard CW Power Sensors. Worst RSS Case System Linearity at 5 MHz.5%.5% Power Linearity at -5 dbm and GHz.%.% Calibrator Uncertainty at 5 MHz.%.% Calibrator/Sensor Mismatch at 5 MHz.3%.3% Calibration Factor Uncertainty at GHz.9% 3.6% Zero Error.6%.6% Noise.6%.6% Mismatch (Sensor/Source) 4.% 4.% Total 4.6% 9.6%
3 Giga-tronics Model 5854 VXIbus Uniersal Power Meter Page 3 of 5 Giga-tronics CW Power Sensor Selection Guide mw CW Power Sensors 83A MHz to 8 GHz +3 dbm ( mw) 7 to dbm: ±. db Type N(m) 4.5 mm 3 mm.8 kg.:. - GHz 7 to + dbm to + dbm: ±.5 db/ db 5Ω (4.5 in) (.5 in) (.4 lb).: -.4 GHz 83A MHz to 8 GHz +3 dbm ( mw) 7 to dbm: ±. db APC mm 3 mm.8 kg.9:.4-8 GHz 7 to + dbm to + dbm: ±.5 db/ db 5Ω (4.5 in) (.5 in) (.4 lb) 833A MHz to 6.5 GHz +3 dbm ( mw) 7 to dbm: ±. db Type K(m) 4.5 mm 3 mm.8 kg.:. - GHz 7 to + dbm to + dbm: ±. db/ db 5Ω (4.5 in) (.5 in) (.4 lb).: -.4 GHz 834A MHz to 4 GHz +3 dbm ( mw) 7 to dbm: ±. db Type K(m) 4.5 mm 3 mm.8 kg.38:.4-8 GHz 7 to dbm to dbm: ±. db/ db 5Ω (4.5 in) (.5 in) (.4 lb).43: GHz.9: GHz Low VSWR CW Power Sensors 83A MHz to 8 GHz +9 dbm (8 mw) 64 to 4 dbm: ±. db Type K(m) 7 mm 3 mm.3 kg.3:. - GHz 64 to +6 dbm 4 to +6 dbm: ±.5 db/ db 5Ω (5. in) (.5 in) (.5 lb).6: - GHz 833A MHz to 6.5 GHz +9 dbm (8 mw) 64 to 4 dbm: ±. db.3: - 8 GHz 64 to +6 dbm 4 to +6 dbm: ±. db/ db.9: GHz 834A MHz to 4 GHz +9 dbm (8 mw) 64 to 4 dbm: ±. db.5: GHz 64 to +6 dbm 4 to +6dBm: ±. db/ db W CW Power Sensors 83A MHz to 8 GHz +3 dbm ( W) 6 to dbm:±. db Type K(m) 7 mm 3 mm.3 kg.:. - GHz 6 to +3 dbm to +3 dbm: ±.5 db/ db 5Ω (5. in) (.5 in) (.5 lb).: - GHz 833A MHz to 6.5 GHz +3 dbm ( W) 6 to dbm: ±. db.8: - 8 GHz 6 to +3 dbm to +3 dbm: ±. db/ db.: GHz 834A MHz to 4 GHz +3 dbm ( W) 6 to dbm: ±. db.36: GHz 6 to + dbm to + dbm: ±. db/ db 5 W CW Power Sensor 83A MHz to 8 GHz +37 dbm (5 W) 5 to dbm: ±. db Type N(m) 5 mm 3 mm.3 kg.:. - 6 GHz 5 to +37 dbm to +37 dbm: ±.5 db/ db 5Ω (5.9 in) (.5 in) (.5 lb).5: GHz.35:.4-8 GHz 5 W CW Power Sensor 3 83A MHz to 8 GHz +44 dbm (5 W) 4 to + dbm: ±. db Type N(m) 3 mm 4 mm.3 kg.:. - 6 GHz 4 to +44 dbm + to +44 dbm: ±.5 db/ db 5Ω (9. in) (4. in) (.6 lb).3: GHz.4:.4-8 GHz 5 W CW Power Sensor 3 835A MHz to 8 GHz +47 dbm (5 W) 4 to + dbm: ±. db Type N(m) 3 mm 4 mm.3 kg.5:. - 6 GHz 4 to +47 dbm + to +47 dbm: ±.5 db/ db 5Ω (9. in) (4. in) (.6 lb).35: GHz.45:.4-8 GHz Giga-tronics True RMS Sensors Selection Guide (f m >.5 MHz) True RMS Sensors (-3 dbm to + dbm) 833A MHz to 8 GHz +33 dbm ( W) 3 to + dbm: ±. db Type K(m) 5 mm 3 mm.7 kg.:. - GHz 8333A MHz to 6.5 GHz 5Ω (6. in) (.5 in) (.6 lb).5: - 8 GHz 8334A MHz to 4 GHz.8: GHz.9: GHz Giga-tronics Bridge Selection Guide Power Range Power (Frequency > 8 GHz) Input Test Port Directivity Weight VSWR Precision CW Return Loss Bridges 85 MHz to 8 GHz +7 dbm (.5 W) 35 to + dbm: ±. db Type N(f) Type N(f) 38 db.34 kg <.7:. - 8 GHz 35 to + dbm + to + dbm: ±. db 5Ω 5Ω <.7: 8-8 GHz ±.5 db/db 854 MHz to 4 GHz +7 dbm (.5 W) 35 to + dbm: ±. db Type K(f) Type K(f) 3 db.98 kg <.35: GHz 35 to + dbm + to + dbm: ±. db 5Ω 5Ω <.44: GHz ±.5 db/db The K connector is electrically and mechanically compatible with the APC-3.5 and SMA connectors. Note: Use a Type N(m) to SMA(f) adapter (part no. 9835) for calibration of power sensors with Type K(m) connectors. Power coefficient equals <. db/watt. 3 Power coefficient equals <.5 db/watt. 4 For frequencies above 8 GHz, add power linearity to system linearity. 5 Power coefficient equals <. db/watt (Average). 6 Power coefficient equals <.5 db/watt (Average). 7 Peak operating range above CW maximum range is limited to <% duty cycle. 8 Square root of the sum of the individual uncertainties squared (RSS). 9 Cal Factor numbers allow for 3% repeatability when reconnecting attenuator to sensor and 3% for attenuator measurement uncertainty and mismatch of sensor/pad combination.
4 Giga-tronics Model 5854 VXIbus Uniersal Power Meter Page 4 of 5 Giga-tronics Peak Power Sensor Selection Guide mw Peak Power Sensors 835A 45 MHz to 8 GHz +3 dbm ( mw) 3 to dbm: ±. db Type N(m) 65 mm 37 mm.3 kg.:.45 - GHz to + dbm, Peak CW or Peak to + dbm: ±.5 db / db 5Ω (6.5 in) (.5 in) (.7 lb).: -.4 GHz 3 to + dbm, CW.37:.4-8 GHz 8353A 45 MHz to 6.5 GHz +3 dbm ( mw) 3 to dbm: ±. db Type K(m) 65 mm 37 mm.3 kg.5: GHz to + dbm, Peak CW or Peak to + dbm: ±. db / db 5Ω (6.5 in) (.5 in) (.7 lb).9: GHz 3 to + dbm, CW 8354A 45 MHz to 4 GHz +3 dbm ( mw) 3 to dbm: ±. db Type K(m) 65 mm 37 mm.3 kg to +. dbm, Peak CW or Peak to. dbm: ±. db / db 5Ω (6.5 in) (.5 in) (.7 lb) 3 to +. dbm, CW 5 W Peak Power Sensor 5, 7 835A 45 MHz to 8 GHz CW: +37 dbm to + dbm: ±. db Type N(m) mm 37 mm.3 kg.5:.45-4 GHz to +4 dbm, Peak (5 W Average) + to +4 dbm: ±.5 db / db 5Ω (7.9 in) (.5 in) (.7 lb).5: GHz to +37 dbm, CW Peak: +43 dbm.35:.4-8 GHz 5 W Peak Power Sensor 6, 7 835A 45 MHz to 8 GHz CW: +44 dbm. to + dbm: ±. db Type N(m) 8 mm 4 mm.3 kg.:.45-6 GHz + to +5 dbm, Peak (5 W Average) + to +5 dbm: ±.5 db / db 5Ω (. in) (4. in) (.7 lb).3: GHz. to +44 dbm, CW Peak: +53 dbm.4:.4-8 GHz 5 W Peak Power Sensor 6, A 45 MHz to 8 GHz CW: +47 dbm. to + dbm: ±. db Type N(m) 8 mm 4 mm.3 kg.5:.45-6 GHz + to +5 dbm, Peak (5 W Average) + to +5 dbm: ±.5 db / db 5Ω (. in) (4. in) (.7 lb).35: GHz. to +47 dbm, CW Peak: +53 dbm.45:.4-8 GHz Sensor Calibration Factor Uncertainties Frequency (GHz) Root Sum of Squares (RSS) Uncertainties(%) 8 833A 83A 834A 83A 83A 83A 9 833A 83A 8353A 833A 833A 83A A Lower Upper 835A 8354A 834A 834A 835A A The K connector is electrically and mechanically compatible with the APC-3.5 and SMA connectors. Note: Use a Type N(m) to SMA(f) adapter (part no. 9835) for calibration of power sensors with Type K(m) connectors. Power coefficient equals <. db/watt. 3 Power coefficient equals <.5 db/watt. 4 For frequencies above 8 GHz, add power linearity to system linearity. 5 Power coefficient equals <. db/watt (Average). 6 Power coefficient equals <.5 db/watt (Average). 7 Peak operating range above CW maximum range is limited to <% duty cycle. 8 Square root of the sum of the individual uncertainties squared (RSS). 9 Cal Factor numbers allow for 3% repeatability when reconnecting attenuator to sensor and 3% for attenuator measurement uncertainty and mismatch of sensor/pad combination.
5 Giga-tronics Model 5854 VXIbus Uniersal Power Meter Specifications Page 5 of 5 Specifications describe the instrument s warranted performance, and apply when using 83A Series Power Sensors. Typical performance, (shown in italics), is non-warranted. METER Frequency Range: MHz to 4 GHz Power Range: -7 dbm to +47 dbm ( pw to 5 Watt) Single Sensor Dynamic Range: CW Power Sensors: 9 db Peak Power Sensors: 4 db, Peak 5 db, CW ACCURACY Calibrator:Power Sweep calibration signal to dynamically linearize the sensors. Frequency: 5 MHz, nominal. Settability: The mw (. dbm) level in the Power Sweep Calibrator is factory set to ±.7% traceable to the NIST.. dbm Accuracy: ±.% worst case for one year, over temperature range of 5 to 35 C. Connector: Type N(f) connector, 5 Ω. VSWR: <.5 (Return Loss >33 db). System Linearity at 5 MHz for Standard CW Sensors: ±. db over any db range from -7 to +6 dbm. ±. db + (+, -.5 db/db) from +6 to + dbm. ±.4 db from -7 to +6 dbm. 83A A A A A A A -3-84A, 86A (CW) SENSORS TYPICAL ERROR (db) Input, (dbm) Graph shows linearity plus zero set and noise vs. input power Zeroing Accuracy: (Standard CW Sensors) Zero Set: <±5 pw Zero Drift: <± pw during hour Noise Uncertainty: <±5 pw measured over a minute interval. MEASUREMENT SPEED Measurement speed increases significantly using data storage capabilities. Storing data in the power meter s memory for later down loading to your controller reduces word serial protocol and protocol conversion overhead. Up to 8, readings can be buffered. The table below illustrates typical maximum measurement rates for 83 Series Peak Power Sensors. Measurement rate depends on several factors including controller speed and number of averages. Burst Mode speed shown does not include bus communication time. Normal Mode Swift Mode Burst Mode Non-Buffered Buffered Data Buffered Data 55 rdgs/s 5 rdgs/s 5 rdgs/s Data is read immediately after measurement in Normal Mode. Swift Mode allows triggering of individual data points, and stores the data in the 5854 s memory. Burst Mode also buffers measurement data. Triggering is controlled by setting the time interval between measurements. FRONT PANEL CONNECTIONS Analog Output: Provides an output voltage con figurable in either Lin or Log units. Normal Mode. Trigger Input: Used to connect EXT trigger. Swift and Burst Modes Voltage proportional to Frequency: Allows automated Cal Factor correction. Input the analog VpropF signal level from the microwave source. Normal Mode. RETURN LOSS BRIDGES Return Loss Bridge Frequency Response: Use the standard Open/Short supplied with the bridge to frequency compensate 5854 return loss and VSWR measurements. Bridge Insertion Loss: 6.5 db, nominal, from input port to test port. Measurement Error (db) Graph shows Bridge Linearity of the GENERAL SPECIFICATIONS Temperature Range: Operating: to 5 C (+3 to + F) Storage: -4 to 7 C (-4 to +58 F) Power Requirements: +5 8 ma +4 5 ma -4 5 ma Physical Characteristics: Dimensions: C-size, single slot VXI standard 3 mm (. in) wide, 34 mm (9. in) high, 34 mm (3.4 in) deep. Weight:.5 kg (5.5 lbs) ORDERING INFORMATION ACCESSORIES One Operation and Maintenance Manual and two detachable sensor cables are included. OPTIONS Add 8K buffer for fast measurements. Stores 8K single channel readings or 64K each dual channel. Depending on sensor used. MAP (Modulated Average Power), PAP (Pulse Average Power), BAP (Burst Average Power). Specifications subject to change without notice. 996 Giga-tronics Incorporated GT-79-B Giga-tronics Incorporated 465 Norris Canyon Road San Ramon, California Telephone: or Telefax: Web Site:
Technical Datasheet GT-8550B Series USB Power Sensor 10 MHz to 26.5 GHz
Technical Datasheet GT-8550B Series USB Power Sensor 10 MHz to 26.5 GHz PC-based Power Meter 35424-Rev.A/ US122112 GT-8550B Series USB Power Sensors GT-8550B Series USB Peak Power Sensors Advanced Power
More information8480 Series Power Sensor Specifications
8480 Series Sensor Specifications NOTE These specifications are valid with EPM and EPM-P Series of power meters. The 8480 series thermocouple and diode power sensors provide accuracy, stability, and SWR
More informationGT-1050A 2 GHz to 50 GHz Microwave Power Amplifier
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Giga-tronics GT-1050A Microwave Power Amplifier GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier Operation Manual
More informationGT 9000 GT 9000S MICROWAVE
Page 1 of 6 GT 9000 GT 9000S MICROWAVE Now you can get the performance you need and the capability you want, at a price you can afford. Both the Giga-tronics GT9000 Microwave Synthe- techniques.together,
More informationLB480A Pulse Profiling USB PowerSensor+ Data Sheet
Key PowerSensor+ Specifications 100 MHz to 8 GHz (functional to 10 GHz) -60 dbm to +20 dbm 1.95% Total Error* 1.09:1 VSWR (-27 db Return Loss) * Measuring a well matched DUT (-20 dbm @ 1 GHz) Measurement
More informationLB480A Pulse Profiling USB PowerSensor+ Data Sheet
Key PowerSensor+ Specifications 50 MHz to 8 GHz (functional to 10 GHz) - 60 dbm to +20 dbm 1.95% Total Error* 1.09:1 VSWR (-27 db Return Loss) * Measuring a well matched DUT (-20 dbm @ 1 GHz) No Zero No
More informationLB679A CW and Pulse (Modulation) USB PowerSensor+ Data Sheet
Key PowerSensor+ Specifications 50 MHz to 20 GHz - 40 dbm to +20 dbm 2.8% Total Error* 1.20:1 VSWR (-21 db Return Loss) * Measuring a well matched DUT (-20 dbm @ 2 GHz) Key PowerSensor+ Capability Test
More informationLB680A Pulse Profiling USB PowerSensor+ Data Sheet
Key PowerSensor+ Specifications 50 MHz to 20 GHz - 40 dbm to +20 dbm 2.8% Total Error* 1.20:1 VSWR (-21 db Return Loss) * Measuring a well matched DUT (-20 dbm @ 2 GHz) Measurement Capability Time Gated
More informationN432A Thermistor Power Meter DATA SHEET
N432A Thermistor Power Meter DATA SHEET Why Keysight s Power Meters and Sensors? Keysight s only power meter that supports thermistor mount with useful enhancements for metrology and calibration lab environments.
More informationHP 8901B Modulation Analyzer. HP 11722A Sensor Module. 150 khz MHz. 100 khz MHz. Technical Specifications. Four Instruments In One
HP 8901B Modulation Analyzer 150 khz - 1300 MHz HP 11722A Sensor Module 100 khz - 2600 MHz Technical Specifications Four Instruments In One RF Power: ±0.02 db instrumentation accuracy RF Frequency: 10
More informationESM Calibration and Testing Using the Giga-tronics 2500B Series Microwave Signal Generators
ESM Calibration and Testing Using the Giga-tronics 2500B Series Microwave Signal Generators Product Note Frequency switching speed as fast as 350 µs per point. The Giga-tronics 2500B Series Microwave Signal
More informationR&S NRP USB and LAN Power Sensors Specifications
R&S NRP USB and LAN Power Sensors Specifications year Test & Measurement Data Sheet 04.00 CONTENTS Definitions... 3 Overview of the R&S NRP power sensors... 4 Specifications in brief of the R&S NRP power
More informationData Sheet. Peak, CW & Average. Power Sensors. Taking performance to a new peak
Data Sheet Peak, CW & Average Power Sensors Taking performance to a new peak Peak, CW & Average Power Sensors The overall performance of a power meter dependents on the power sensor employed. Boonton has
More informationLadyBug Technologies, LLC LB5918L True-RMS Power Sensor
LadyBug Technologies, LLC LB5918L True-RMS Power Sensor LB5918L-Rev-9 LadyBug Technologies www.ladybug-tech.com Telephone: 707-546-1050 Page 1 LB5918L Data Sheet Key PowerSensor+ TM Specifications Frequency
More informationLadyBug Technologies, LLC LB5926A True-RMS Power Sensor
LadyBug Technologies, LLC LB5926A True-RMS Power Sensor LB5926A-Rev-7 LadyBug Technologies www.ladybug-tech.com Telephone: 707-546-1050 Page 1 LB5926A Data Sheet Key PowerSensor+ TM Specifications Frequency
More information772D coaxial dual-directional coupler 773D coaxial directional coupler. 775D coaxial dual-directional coupler 776D coaxial dual-directional coupler
72 772D coaxial dual-directional coupler 773D coaxial directional coupler 775D coaxial dual-directional coupler 776D coaxial dual-directional coupler 777D coaxial dual-directional coupler 778D coaxial
More informationTechnical Datasheet GT-1050B Microwave Power Amplifier. 2 GHz to 50 GHz. Broadband High-Power Instrumentation Amplifier Rev.
Technical Datasheet GT-1050B Microwave Power Amplifier 2 GHz to 50 GHz Broadband High-Power Instrumentation Amplifier 35527 -Rev.A / US130711 Advanced Amplifier Technology 2 GHz to 50 GHz eliminates band
More informationAgilent 8902A Measuring Receiver
Agilent 8902A Measuring Receiver Technical Specifications Agilent 11722A Sensor Module Agilent 11792A Sensor Module Agilent 11793A Microwave Converter Agilent 11812A Verification Kit The Agilent Technologies
More informationPM Series Microwave Power Calibration System
PM Series Microwave Power Calibration System Supports Sensors from most major manufacturers from 6 khz to 50 GHz Faster than direct compare method Lowest total uncertainty National Metrology Institute
More informationR&S NRP Power Meter Family Specifications
R&S NRP Power Meter Family Specifications year Data Sheet Version 06.00 CONTENTS Definitions... 3 Overview of the R&S NRP power sensors... 4 Specifications in brief of the R&S NRP power sensors... 5 Multipath
More informationSWR/Return Loss Measurements Using System IIA
THE GLOBAL SOURCE FOR PROVEN TEST SWR/Return Loss Measurements Using System IIA SWR/Return Loss Defined Both SWR and Return Loss are a measure of the divergence of a microwave device from a perfect impedance
More informationAgilent EPM Series Power Meters
Agilent EPM Series Power Meters The standard just got better! What s new? Fast measurement speeds (up to 200 readings per second) Wide dynamic range sensors (-70 dbm to +44 dbm), sensor dependent Calibration
More informationContents. CALIBRATION PROCEDURE NI PXIe-5668R 14 GHz and 26.5 GHz Signal Analyzer
CALIBRATION PROCEDURE NI PXIe-5668R 14 GHz and 26.5 GHz Signal Analyzer This document contains the verification procedures for the National Instruments PXIe-5668R (NI 5668R) vector signal analyzer (VSA)
More informationHP 8901B Modulation Analyzer. HP 11722A Sensor Module. 150 khz MHz. 100 khz MHz. Technical Specifications. Four Instruments In One
HP 8901B Modulation Analyzer 150 khz - 1300 MHz HP 11722A Sensor Module 100 khz - 2600 MHz Technical Specifications Four Instruments In One RF Power: ±0.02 db instrumentation accuracy RF Frequency: 10
More informationMicrowave. Accessories for Microwave Scalar and System Analyzers
Microwave Accessories for Microwave Scalar and System Analyzers The following optional accessories are designed for use with the 6200B series of Microwave Test Sets, the 6820 series Scalar Analyzers and
More informationAgilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet
Agilent N1911A/N191A P-Series Power Meters and N191A/N19A Wideband Power Sensors Data sheet Specification Definitions There are two types of product specifications: Warranted specifications are specifications
More informationAgilent Technologies PSA Series Spectrum Analyzers Test and Adjustment Software
Test System Overview Agilent Technologies PSA Series Spectrum Analyzers Test and Adjustment Software Test System Overview The Agilent Technologies test system is designed to verify the performance of the
More informationDSA700 Series Spectrum Analyzer
DSA700 Series Spectrum Analyzer Product Features: All-Digital IF Technology Frequency Range from 100 khz up to 1 GHz Min. -155 dbm Displayed Average Noise Level (Typ.) Min.
More informationTechnical Information
Technical Information Power Sensor R&S NRP-Z91 Universal power measurement from 9 khz to 6 GHz The Power Sensor R&S NRP-Z91 is designed for measuring average power in a very wide frequency range. In particular,
More informationAgilent 8560 EC Series Spectrum Analyzers Data Sheet
Agilent 8560 EC Series Spectrum Analyzers Data Sheet Agilent 8560EC 30 Hz to 2.9 GHz Agilent 8561EC 30 Hz to 6.5 GHz 1 Agilent 8562EC 30 Hz to 13.2 GHz Agilent 8563EC 30 Hz to 26.5 GHz Agilent 8564EC 30
More informationPower Measurement Basics
Back to Basics - 2006 Objectives On completion of this module, you will be able to: Explain the importance of power measurements Define the three basic types of power measurements Describe the power meter/sensor
More informationAgilent U2000 Series USB Power Sensors. Data Sheet
Agilent U2000 Series USB Power Sensors Data Sheet Features Perform power measurement without a power meter Frequency range from 9 khz to 24 GHz (sensor dependent) Dynamic range from 60 dbm to +20 dbm Internal
More informationMA24104A. Inline High Power Sensor. True-RMS, 600 MHz to 4 GHz
Product Brochure MA24104A Inline High Power Sensor True-RMS, 600 MHz to 4 GHz A Standalone, Compact, and Highly Accurate Inline High Power Sensor for your RF Power Measurement Needs MA24104A at a Glance
More informationAgilent 8901B Modulation Analyzer (150 khz 1300 MHz) and Agilent 11722A Sensor Module (100 khz 2600 MHz) Four Instruments In One
Agilent 8901B Modulation Analyzer (150 khz 1300 MHz) and Agilent 11722A Sensor Module (100 khz 2600 MHz) Four Instruments In One Data Sheet RF Power: ±0.02 db instrumentation accuracy RF Frequency: 10
More informationKeysight Technologies E8257D PSG Microwave Analog Signal Generator. Data Sheet
Keysight Technologies E8257D PSG Microwave Analog Signal Generator Data Sheet 02 Keysight E8257D Microwave Analog Signal Generator - Data Sheet Table of Contents Specifications... 4 Frequency... 4 Step
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationAgilent ESA-L Series Spectrum Analyzers
Agilent ESA-L Series Spectrum Analyzers Data Sheet Available frequency ranges E4403B E4408B 9 khz to 1.5 GHz 9 khz to 3.0 GHz 9 khz to 26.5 GHz As the lowest cost ESA option, these basic analyzers are
More informationTechnical Information
Technical Information Power Sensors R&S NRP-Z51, -Z55 Thermoelectric accuracy at its best The new power sensors for the frequency ranges DC to 18 GHz (R&S NRP-Z51) and DC to 40 GHz (R&S NRP-Z55) for the
More information2400C Series Microwave Signal Generators 10 MHz to 40 GHz. Preliminary Technical Datasheet. Low Phase Noise and Fast-Switching Speed in a Single Unit
Preliminary Technical Datasheet 2400C Series Microwave Signal Generators 10 MHz to 40 GHz Low Phase Noise and Fast-Switching Speed in a Single Unit 2400C Series Microwave Signal Generator Signal Generator
More informationModel 865 RF / Ultra Low Noise Microwave Signal Generator
Model 865 RF / Ultra Low Noise Microwave Signal Generator Features Excellent signal purity: ultra-low phase noise and low spurious Combination of highest output power and fastest switching Powerful touch-display
More informationKeysight Technologies E8257D PSG Microwave Analog Signal Generator
Ihr Spezialist für Mess- und Prüfgeräte Keysight Technologies E8257D PSG Microwave Analog Signal Generator Data Sheet datatec Ferdinand-Lassalle-Str. 52 72770 Reutlingen Tel. 07121 / 51 50 50 Fax 07121
More informationAgilent EPM-P Series Single- and Dual-Channel Power Meters Agilent E9320 Family of Peak and Average Power Sensors
Agilent EPM-P Series Single- and Dual-Channel Power Meters Agilent E9320 Family of Peak and Average Power Sensors Product Overview The power measurement solution you ve been looking for Ideal for today
More informationAgilent 8560 E-Series Spectrum Analyzers
Agilent 8560 E-Series Spectrum Analyzers Data Sheet 8560E 30 Hz to 2.9 GHz 8561E 30 Hz to 6.5 GHz 8562E 30 Hz to 13.2 GHz 8563E 30 Hz to 26.5 GHz 8564E 30 Hz to 40 GHz 8565E 30 Hz to 50 GHz 8565E SPECTRUM
More informationSIGNAL GENERATORS. MG3633A 10 khz to 2700 MHz SYNTHESIZED SIGNAL GENERATOR GPIB
SYNTHESIZED SIGNAL GENERATOR MG3633A GPIB For Evaluating of Quasi-Microwaves and Measuring High-Performance Receivers The MG3633A has excellent resolution, switching speed, signal purity, and a high output
More informationAgilent EPM Series Power Meters E-Series and 8480 Series Power Sensors. Data Sheet. Product specifications and characteristics
Agilent EPM Series Power Meters E-Series and 8480 Series Power Sensors Data Sheet Product specifications and characteristics EPM series E4418B and E4419B power meters Specifications Specifications describe
More informationRF and Microwave Power Sensors/Meters Tektronix PSM3000, PSM4000, and PSM5000 Series Data Sheet
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com RF and Microwave Sensors/Meters Tektronix PSM3000, PSM4000, and PSM5000 Series
More informationAttenuators 39. Attenuators. Accuracy. Applications. Key specifications SWR
Attenuators Attenuators 39 Applications Agilent fixed and step attenuators 1 find use in a wide variety of applications for signal conditioning and level control. Reducing signal levels Matching impedances
More informationR&S NRP USB and LAN Power Sensors Specifications
R&S NRP USB and LAN Power Sensors Specifications year warranty Test & Measurement Data Sheet 03.00 CONTENTS Definitions... 3 Overview of the R&S NRP power sensors... 4 Specifications in brief of the R&S
More informationSeries 8540C Universal Power Meters
Manual Part Number: Revision: Print Date: 30280 J September 2000 Series 8540C Universal Power Meters Operation & Maintenance Manual... Certified Product ISO 9001...Certified Process Registrar: BSI, Certification
More informationCost-Effective Traceability for Oscilloscope Calibration. Author: Peter B. Crisp Head of Metrology Fluke Precision Instruments, Norwich, UK
Cost-Effective Traceability for Oscilloscope Calibration Author: Peter B. Crisp Head of Metrology Fluke Precision Instruments, Norwich, UK Abstract The widespread adoption of ISO 9000 has brought an increased
More informationE-series E9300 Average Power Sensor Specifications
E-series E9300 Average Power Sensor Specifications The E-series E9300 wide dynamic range, average power sensors are designed for use with the EPM family of power meters. These specifications are valid
More informationHP 8560 E-Series Spectrum Analyzers Technical Specifications
HP 8560 E-Series Spectrum Analyzers Technical Specifications HP 8560E 30 Hz to 2.9 GHz HP 8561E 30 Hz to 6.5 GHz HP 8562E 30 Hz to 13.2 GHz HP 8563E 30 Hz to 26.5 GHz HP 8564E 30 Hz to 40 GHz HP 8565E
More informationMeasurements 2: Network Analysis
Measurements 2: Network Analysis Fritz Caspers CAS, Aarhus, June 2010 Contents Scalar network analysis Vector network analysis Early concepts Modern instrumentation Calibration methods Time domain (synthetic
More informationModel 845-M Low Noise Synthesizer
Model 845-M Low Noise Synthesizer Features Low phase noise Fast switching down to 20 µs FM, Chirps, Pulse Internal OCXO, external variable reference Single DC supply Applications ATE LO for frequency converters
More informationPower Meter. Measurement Guide. for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master
Measurement Guide Power Meter for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master Power Meter Option 29 High Accuracy Power Meter Option 19 Inline Peak
More informationRESISTIVE POWER SPLITTERS AND DIVIDERS
RESISTIVE POWER SPLITTERS AND DIVIDERS DC 40.0 GHz S Resistive Power Splitters Usage: : Use in RF and wireless applications where one of the two outputs are included in a leveling loop or used as a reference
More information87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.
20 Amplifiers 83020A microwave 875A microwave 8308A microwave 8307A microwave 83006A microwave 8705C preamplifier 8705B preamplifier 83050/5A microwave The Agilent 83006/07/08/020/050/05A test s offer
More informationMG3740A Analog Signal Generator. 100 khz to 2.7 GHz 100 khz to 4.0 GHz 100 khz to 6.0 GHz
Data Sheet MG3740A Analog Signal Generator 100 khz to 2.7 GHz 100 khz to 4.0 GHz 100 khz to 6.0 GHz Contents Definitions, Conditions of Specifications... 3 Frequency... 4 Output Level... 5 ATT Hold...
More informationModel 745 Series. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since Model 845-HP Datasheet BNC
Model 845-HP Datasheet Model 745 Series Portable 20+ GHz Microwave Signal Generator High Power +23dBM Power Output 250 fs Digital Delay Generator BNC Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation
More informationKeysight Technologies N9320B RF Spectrum Analyzer
Keysight Technologies N9320B RF Spectrum Analyzer 9 khz to 3.0 GHz Data Sheet Definitions and Conditions The spectrum analyzer will meet its specifications when: It is within its calibration cycle It has
More informationChapter 6 Specifications
RIGOL This chapter lists the technical specifications and general specifications of the RF signal generator. The technical specifications are valid when the instrument is within the calibration period,
More informationAgilent N9320B RF Spectrum Analyzer
Agilent N9320B RF Spectrum Analyzer 9 khz to 3.0 GHz Data Sheet Definitions and Conditions The spectrum analyzer will meet its specifications when: It is within its calibration cycle It has been turned
More informationDATA SHEET. N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors
DATA SHEET N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors LXI Class-C-Compliant Power Meter A P-Series power meter is a LXI Class-C-compliant instrument, developed using LXI
More informationAgilent N9923A FieldFox RF Vector Network Analyzer 2 MHz to 4/6 GHz. Data Sheet
Agilent N9923A FieldFox RF Vector Network Analyzer 2 MHz to 4/6 GHz Data Sheet Table of Contents Definitions... 2 FieldFox RF Vector Network Analyzer... 3 Cable and Antenna Analyzer (Option 305)... External
More informationChapter 5 Specifications
RIGOL Specifications are valid under the following conditions: the instrument is within the calibration period, is stored for at least two hours at 0 to 50 temperature and is warmed up for 40 minutes.
More informationR&S FSWP Phase Noise Analyzer Specifications
R&S FSWP Phase Noise Analyzer Specifications Data Sheet Version 06.00 CONTENTS Definitions... 4 Specifications... 5 Frequency... 5 Phase noise measurements... 5 Phase noise sensitivity with R&S FSWP-B61
More informationFrequency range 100 khz to 3 GHz 100 khz to 6 GHz 10 MHz to 18 GHz Reference frequency. 2 ppm in addition 2 ppm/10 C. 0 Hz, 100 Hz to 3 GHz
Specifications Specifications apply under the following conditions: 15 minutes warm-up time at ambient temperature, specified environmental conditions met, and calibration cycle adhered to. Data without
More informationPXIe Contents. Required Software CALIBRATION PROCEDURE
CALIBRATION PROCEDURE PXIe-5160 This document contains the verification and adjustment procedures for the PXIe-5160. Refer to ni.com/calibration for more information about calibration solutions. Contents
More informationDigital Step Attenuator
Surface Mount Digital Step Attenuator 50Ω 0 to 31.5, 0.5 Step DC to 4.0 GHz ZX76-31R5A+ Series The Big Deal Wideband, operates up to 4 GHz Immune to latchup High IP3, 52 m Control inputs buffered by Schmitt
More information100 Hz to 22. HP 8566B Spectrum Analyzer. Discontinued Product Support Information Only. Outstanding Precision and Capability
Discontinued Product Support Information Only This literature was published years prior to the establishment of Agilent Technologies as a company independent from Hewlett-Packard and describes products
More informationAgilent 86030A 50 GHz Lightwave Component Analyzer Product Overview
Agilent 86030A 50 GHz Lightwave Component Analyzer Product Overview 2 Characterize 40 Gb/s optical components Modern lightwave transmission systems require accurate and repeatable characterization of their
More informationR&S NRP-Zxx Power Sensors Specifications
R&S NRP-Zxx Power Sensors Specifications year Data Sheet Version 11.00 CONTENTS Definitions... 3 Overview of the R&S NRP-Zxx power sensors... 4 Specifications in brief of the R&S NRP-Zxx power sensors...
More informationCAA-100A Cable & Antenna Analyzer + Spectrum Analyzer
CAA-100A Cable & Antenna Analyzer + Spectrum Analyzer ShinewayTech CAA-100A cable & antenna analyzer with spectrum analyzer can test DTF/Frequency Return Loss, VSWR, Cable Loss, RF Power and Spectrum.
More informationMicrowave Power Amplifiers for Broadband Applications
Microwave Power Amplifiers for Broadband Applications White Paper by Leonard Dickstein, Marketing Manager A mplifiers are one of the most basic electrical elements in any electronic system. Broadband microwave
More informationContents. CALIBRATION PROCEDURE NI PXIe-5698
CALIBRATION PROCEDURE NI PXIe-5698 This document contains the verification and adjustment procedures for the National Instruments PXIe-5698 (NI 5698). See ni.com/calibration for more information about
More informationPhase Matrix, Inc. 545B 548B. Phase Matrix, Inc. EIP 545B and 548B CW Frequency Counters. Instruments You Can Count On
Phase Matrix, Inc. Instruments You Can Count On 545B 548B Phase Matrix, Inc. EIP 545B and 548B CW Frequency Counters Full Function CW Microwave Frequency Counters with Selective Power Measurement Keyboard
More informationINSTRUCTION SHEET WIDEBAND POWER SENSOR MODEL Copyright 2008 by Bird Electronic Corporation Instruction Book P/N Rev.
INSTRUCTION SHEET WIDEBAND POWER SENSOR MODEL 5012 Copyright 2008 by Bird Electronic Corporation Instruction Book P/N 920-5012 Rev. C Description The Bird 5012 Wideband Power Sensor (WPS) is a Thruline
More information2026Q CDMA/GSM Interferer MultiSource Generator
Signal Sources 2026Q CDMA/GSM Interferer MultiSource Generator The 2026Q is designed to work with a radio test set to provide a fully integrated radio receiver test solution for cellular and PCS systems
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationRadio Frequency Power Meter Design Project
Radio Frequency Power Meter Design Project Timothy Holt and Andrew Milks University of Akron, Akron Ohio Abstract This student paper discusses a radio frequency power meter developed and prototyped as
More informationTest & Calibration Benefits from a New Precision RF/Microwave Calibrator
Test & Calibration Benefits from a New Precision RF/Microwave Calibrator Topics: RF & Microwave calibration signal requirements Design philosophy and architecture of the new RF Calibrator. Spectrum analyzer
More informationDSA800. No.1 RIGOL TECHNOLOGIES, INC.
No.1 DSA800 9 khz to 1.5 GHz Frequency Range Typical -135 dbm Displayed Average Noise Level (DANL) -80 dbc/hz @10 khz offset Phase Noise Total Amplitude Uncertainty
More informationAgilent CSA Spectrum Analyzer
Agilent CSA Spectrum Analyzer N1996A Exceptional performance... anytime, anywhere Frequency coverage Frequency range: 100 khz to 3 or 6 GHz Signal source: 10 MHz to 3 or 6 GHz Preamplifier to 3 or 6 GHz
More informationData Sheet SC5317 & SC5318A. 6 GHz to 26.5 GHz RF Downconverter SignalCore, Inc. All Rights Reserved
Data Sheet SC5317 & SC5318A 6 GHz to 26.5 GHz RF Downconverter www.signalcore.com 2018 SignalCore, Inc. All Rights Reserved Definition of Terms 1 Table of Contents 1. Definition of Terms... 2 2. Description...
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) INSTRUCTION MANUAL MODEL 960 SERIES MICRO SWEEP 1 TO 18.0 GHz MICROWAVE GENERATORS 1985 Wavetek THIS DOCUMENT CONTAINS
More informationTraceability for Oscilloscopes and Oscilloscope Calibrators
Traceability for Oscilloscopes and Oscilloscope Calibrators in relation to RF Voltage measurements Paul C. A. Roberts Fluke Precision Measurement PCAR Traceability for Scope Cal Mar 2006 1 Introduction
More informationDecember 2012 Number Linearity Testing in the SureCAL Power Sensor Package FLEXIBLE STANDARDS ASSIGNMENT
Overview: December 2012 Number 201202 Linearity Testing in the SureCAL Power Sensor Package This Technical Note describes linearity testing utilized in the SureCAL Power Sensor Package for power sensors
More informationTechnical Datasheet GT-1000B Microwave Power Amplifier. 100 MHz to 20 GHz. Broadband High-Power Instrumentation Amplifier Rev.
Technical Datasheet GT-1000B Microwave Power Amplifier 100 MHz to 20 GHz Broadband High-Power Instrumentation Amplifier 35113-Rev.A / US050113 Advanced Amplifier Technology 100 MHz to 20 GHz eliminates
More informationRF Signal Generator RIGOL TECHNOLOGIES, INC.
DSG800 Series RF Signal Generator Highly cost-effective economical RF signal generator Up to -105 dbc/hz (typical) phase noise Up to +20 dbm (typical) maximum output power Higher level of amplitude accuracy,
More informationN8480 Series Thermocouple Power Sensors DATA SHEET
N8480 Series Thermocouple Power Sensors DATA SHEET Introduction The Keysight Technologies, Inc. N8480 Series thermocouple power sensors are amongst the most accurate and reliable sensors, plus they include
More informationObtaining Flat Test Port Power with the Agilent 8360 s User Flatness Correction Feature. Product Note
Obtaining Flat Test Port Power with the Agilent 8360 s User Flatness Correction Feature Product Note 8360-2 Introduction The 8360 series synthesized sweepers provide extremely flat power at your test port,
More informationKeysight Technologies 1 mw 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter. Application Note
Keysight Technologies 1 mw 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter Application Note Introduction This application note explains the application procedure for using the
More informationThermal Power Sensor
Test and Measurement Division Manual Thermal Power Sensor R&S NRP-Z51 DC to 18 GHz / 1 µw to 100 mw 1138.0005.02 R&S NRP-Z55 DC to 40 GHz / 1 µw to 100 mw 1138.2008.02 Printed in the Federal Republic of
More informationAgilent 8560 EC Series Spectrum Analyzers Data Sheet
Agilent 8560 EC Series Spectrum Analyzers Data Sheet Agilent 8560EC 30 Hz to 2.9 GHz 1 Agilent 8561EC 30 Hz to 6.5 GHz 1 Agilent 8562EC 30 Hz to 13.2 GHz 1 Agilent 8563EC 30 Hz to 26.5 GHz 1 Agilent 8564EC
More informationPXIe Contents CALIBRATION PROCEDURE
CALIBRATION PROCEDURE PXIe-5632 This document contains the verification and adjustment procedures for the PXIe-5632 Vector Network Analyzer. Refer to ni.com/calibration for more information about calibration
More informationContents. CALIBRATION PROCEDURE NI PXIe GHz and 14 GHz RF Vector Signal Analyzer
CALIBRATION PROCEDURE NI PXIe-5665 3.6 GHz and 14 GHz RF Vector Signal Analyzer This document contains the verification procedures for the National Instruments PXIe-5665 (NI 5665) RF vector signal analyzer
More informationAgilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise
More informationNI PXIe-5601 Specifications
NI PXIe-5601 Specifications RF Downconverter This document lists specifications for the NI PXIe-5601 RF downconverter (NI 5601). Use the NI 5601 with the NI PXIe-5622 IF digitizer and the NI PXI-5652 RF
More informationR&S SMB100N SIGNAL GENERATOR
R&S SMB100N SIGNAL GENERATOR PERFORMANCE SPECIFICATIONS VERSION 02.00, SEPTEMBER 2009 CONTENTS Specifications...3 Definitions... 3 RF performance... 4 Frequency... 4 Frequency sweep... 4 Reference frequency...
More informationSpecification RIGOL. 6 Specification
Specification RIGOL 6 Specification This chapter lists the specifications and general specifications of the analyzer. All the specifications are guaranteed when the following conditions are met unless
More information