CONTENTS. For Smart Industry. Measuring Principles. Applications. Closed-Loop Current Sensor * JP-50/100 * JP-200 * JPC-2000X * JPC-300X * JPC-500X

Size: px
Start display at page:

Download "CONTENTS. For Smart Industry. Measuring Principles. Applications. Closed-Loop Current Sensor * JP-50/100 * JP-200 * JPC-2000X * JPC-300X * JPC-500X"

Transcription

1

2 J&D is a market leader in current and voltage sensors. Built with its advanced I and IoT technology, J&D is launching products such as the Outdoor Waterproof Rogowski Coil CT, the SplitCore Power etering CT, an dvanced Power Quality eter, a Branch Circuit Power eter and a Wireless Distribution Transformer onitoring System. The brand new PQCT Series, which consists of the JPS Series SplitCore CT and the JRFSR Series Rogowski coil CT, can be used for power quality monitoring and highly accurate revenue grade metering for both C and DC current. J&D's new products are the best solution for smart grid applications such as V / LV substations, power quality meters, energy meters, branch circuit meters, PV monitoring, motor quality diagnostics, Traction and data center,etc

3 CONTENTS For Smart Industry easuring Principles pplications ClosedLoop Current Sensor * JP50/00 * JP00 * JPC00X * JPC00X * JPC500X * JPC000X * JPC000X OpenLoop Current Sensor /Technology PQCT * * * * * * * JHOXXXG(/B) Series JHOXXXC(/B) Series JHOXXXXD Series JXHXXXXXX Series JSXXXHXXX Series JPSXXH Series JHOXXXXSD(/B) Series ClosedLoop Voltage Sensor * JHVC5 9 Digital Voltage Sensor * EVS0XXXXX Series * EVS0XXXX Series Checklist for Customers 0

4 for Smart Industry The importance of Smart Industrial applications is increasing in order to save energy and cost. Smart Industrial applications are controlled by power loss and accurate regulation of electronic parameters such as current, voltage and power. J&D uses innovative technologies to ensure the high degree of reliability and safety that our customers require. J&D offers a comprehensive range of accurate, reliable and galvanically isolated devices to measure C/DC current from to 6000 and C/DC voltage from 0V to 000V by acrossing wide range of technologies. J&D CT are UL/CE marked in recognition of their electromagnetic compatibility and compliance to Safety standards. Typical applications include Power supplies for welding, medical, Elevators Servo motor drives & Inverters Uninterruptible power supplies (UPS) PV monitoring Pumps & fans control/monitoring Traction & Trackside Converters, Rectifiers Solar / Photovoltaics New Precision Hall effect Technology

5 easuring Principles J&D C/DC CTs provide noncontact detection of C/DC current. The C/DC CTs have two types of splitcore & solidcore design with various utility, high reliability & Costeffective solution for precise current measurements. The rated current range is 5 to 6000 C/DC and secondary output value is /5/0 V/mV DC & 0 m, Instantaneous C/DC current. I N +V 0V V easuring Principle of OpenLoop Current Technology Openloop Hall effect technology creates magnetic flux from the input primary current and its magnetic flux couples a proportional low voltage, which amplify before being output. I N RL V +V 0V V easuring Principle of ClosedLoop Current Technology The secondary current is generated by transferring the proportional voltage of the hall sensor originated by the magnetic flux from the primary current. The feedback of the compensating current via the secondary winding closes the loop, where by this current is an exact representation of the primary current. J&D C/DC VT offers a comprehensive range of accurate, reliable and galvanically isolated devices to measure C/DC voltage from 0V to 000V across a range of technologies. V Ri NP IP W W W RL V +V 0V V easuring Principle of ClosedLoop Voltage Technology When a primary Voltage is applied to the input resistor R i, the current I p flows through the wire of the input W coil and generates a magnetic flux passing the Hall Sensor. The closedloop feedback amplifier used the Hall Voltage to generate a compensating current which is applied to the secondary winding W thereby creating the compensating magnetizing flux. This current is exactly proportional to primary current I p through R i and the input Voltage V m and as it flows through the output metering resistor R L it creates a voltage drop V m which is proportional to the Primary Voltage Vm. Dependent on the ratio Ri/Rl you can get a wished voltage transfer ratio. + HT HT IS + R V +V 0V V easuring Principle of Isolation mplifier Technology Our Isolation mplifier Technology Voltage Sensors isst EVS series begins with an internal resistor network. This network measures DC Voltage by directly contacting both the Positive High Voltage (+HT) and the Negative High Voltage (HT). This Voltage signal is transmitted to the secondary side of the sensor through an insulated transformer that isolates the Primary High Voltage from the Secondary Low Voltage. The resulting signal is then converted through an amplifier into either a current or a Voltage signal. Therefore the circuit converts a primary Voltage into a secondary current or Voltage that is proportional to the input. 5

6 pplications C Variable Speed Drives and Servo otor Drives ~ ~ ~ ~ ~ IL ~ ~ G ~ ~ IG Rectifier or Inverter Rectifier or Inverter DCLink ~ DCLink VDC IDC VDC IDC ~ PW Inverter PW Inverter I IL Static Converters for DC otor Drives ~ ~ ~ ~ Converter ~ Field Rectifier Ip I ~ Battery Supplied pplications ~ ~ ~ Charger Battery Ip ~ ~ ~ Inverter I Uninterruptible Power Supplies (UPS) ~ ~ ~ ~ VDC Charger DCLink Battery Inverter IDC I Switched ode Power Supplies (SPS) ~ ~ ~ Input Rectifier DCLink VDC IDC PW Inverter Output Rectifier I I C Power Supplies for Welding pplications ~ ~ ~ Input Rectifier DCLink VDC IDC PW Inverter Output Rectifier DC I 6

7 7

8 PCB ClosedLoop Current Sensor JP50/00 Features Closed loop (compensated) current transducer using the Hall effect Printed circuit board mounting Insulated plastic case recognized according to UL 9V0. Electrical Properties odel Primary nominal current easuring resistance Rated output current Output current accuracy Offset current Output linearity Power supply voltage Response time Frequency characteristics Thermal drift of gain Thermal drift of offset Hysteresis error Insulation voltage Insulation resistance mbient Operating temperature mbient storage temperature Secondary coil resistance Dimension If R L I O V I of ε L V CC tr f TCI O TCI Of I oh V D R IS T T S R S JP50 50 ±50 : 60Ω ~ ±60 : 60Ω ±50 : 5Ω ~ ±55 : 5Ω 50m ( Turn ratio 000) ±0.5 (±5V, +5 C ) ±0.65 (±5V, +5 C ) ±0.m (at If=0) ±0.m (at If=0) ±0.5%(at If) ±V ±5% ~ ±5V ±5% (output current is restricted by Vcc) μs(at di/dt=if/μs) DC 00kHz ( db) ± 0.0%/ C(Without TcIof) ± 0.5m 0.m (at If=0 If If=0) C000V for minute (Sensing current 0.5m) inside of through hole terminal Connection JP00 00 ±00 : 0Ω ~ ±0 : 0Ω ~ Ω ±00 : 0Ω ~ ±50 : 0Ω ~ 5Ω 50m ( Turn ratio 000) 500Ω (at DC500V) inside of through hole terminal 0 C ~ +85 C 0 C ~ +90 C 80Ω(@Ta=70 C) 0Ω(@Ta=70 C) 85Ω(@Ta=85 C) 8Ω(@Ta=85 C) Unit : mm [inch] IP Unless otherwise specified, tolerances shall be ±0.5mm + IS Rm +Vc 0V Vc 8

9 ClosedLoop Current Sensor JP00 PCB Features Closed loop (compensated) current transducer using the Hall effect Printed circuit board mounting Insulated plastic case recognized according to UL 9V0. Electrical Properties odel Primary nominal current easuring resistance Rated output current Output current accuracy Offset current Output linearity Power supply voltage Response time Frequency characteristics Thermal drift of gain Thermal drift of offset Hysteresis error Insulation voltage Insulation resistance mbient Operating temperature mbient storage temperature Secondary coil resistance Dimension If R L I O V I of ε L V CC tr f TCI O TCI Of I oh V D R IS T T S R S JP00 00 ±00 : 0Ω ~ 6Ω ±50 : 0Ω ~ Ω ±00 : 0Ω ~ 56Ω ±00 : 0Ω ~ 8Ω 00m ( Turn ratio 000) ±0. (±5V, +5 C ) ±0.m (at If=0) ±0.5%(at If) ±V ±5% ~ ±5V ±5% (Rated output current is restricted by Vcc) μs(at di/dt=if/μs) DC 00kHz ( db) ± 0.0%/ C(Without TcIof) ± 0.5m 0.m (at If=0 If If=0) C000V for minute (Sensing current 0.5m) inside of through hole terminal 500Ω (at DC500V) inside of through hole terminal 0 C ~ +85 C 0 C ~ +90 C 76Ω(@Ta=70 C) 80Ω(@Ta=85 C) Connection Ø Unit : mm [inch] IP IS Rm + Unless otherwise specified, tolerances shall be ±0.5mm 0V +Vc Vc NC 9

10 Panel ClosedLoop Current Sensor JPC00X For the electronic measurement of currents : C/DC current sensor, JPC series has good stability in high currents and a highly insulated primary and secondary. dvantages Low temperature drift Excellent accuracy Optimized response time Very good linearity Wide frequency bandwidth No insertion losses High immunity to external interference Current overload capability. pplications C variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched ode Power Supplies (SPS) Power supplies for welding applications. Features Closed loop (compensated) current transducer using the Hall effect Insulated plastic case recognized according to UL 9V0 Panel mounting Specification ODEL SPEC Primary nominal current rms Primary current, measuring range easuring resistance Ω Secondary nominal current rms Conversion ratio Supply voltage (+/5%) Current ± 5 V Overall accuracy Linearity error m V m % % m m JPC00F 98800[556600] olex 80069[600C(0)] olex ± 0 ± ± 00 Ta=70 C : 0 ~ 7 Ta=85 C : 0 ~ ± 0 Ta=70 C : 0 ~ Ta=85 C : 0 ~ ± ± 00 Ta=70 C : 0 ~ 00 Ta=85 C : ~ ± 0 Ta=70 C : 0 ~ 8 Ta=85 C : ~ 6 00 : 000 ± I S ± 0.5 < 0. ax. ± 0. ax. ± 0.(@ I P, after an overload of x I PN ) C 500V / min. Typ. ± 0., ax. ± 0. (5 C C) < 500 < (With a di/dt of 00 /µs.) > 00 DC (@Ta=70 C) / 5 (@Ta=85 C) Insulation voltage V D Temperature variation m Reaction time to 0 % of I PN step ns Reaction time to 90 % of I PN step di/dt accurately followed Frequency bandwidth ( db) khz mbient Operating temperature C mbient storage temperature C Secondary coil resistance Ω ass g 78 Standards EN 5078: 997 / IEC 600 JPC00T 0

11 ClosedLoop Current Sensor JPC00X Panel Dimensions(mm) JPC00F IP + IS Rm 0V +Vc Vc NC..5.. R anufacturer Part Number Old Part Number olex Primary throughhole Ø 5.5 mm Detail JPC00T. IS Rm I P + 0V +Vc Vc..5.. R B anufacturer Part Number Old Part Number olex C (0) Primary throughhole Ø 5.5 mm Terminal No. Detail B

12 Panel ClosedLoop Current Sensor JPC00X For the electronic measurement of currents : C/DC current sensor, JPC series has good stability in high currents and a highly insulated primary and secondary. dvantages Low temperature drift Excellent accuracy Optimized response time Very good linearity Wide frequency bandwidth No insertion losses High immunity to external interference Current overload capability. pplications C variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched ode Power Supplies (SPS) Power supplies for welding applications. Features Closed loop (compensated) current transducer using Insulated plastic case recognized according to UL 9V0 Panel mounting Specification ODEL SPEC Primary nominal current rms Primary current, measuring range easuring Ω Secondary nominal current rms Conversion ratio Supply voltage (+ 5 %) Current ± 5 V Overall accuracy Linearity error m V m % % m m JPC00F 98800[556600] olex 0.. ± 500 ± ± 00 Ta=70 C : 0 ~ ± 500 Ta=70 C : 0 ~ 0 ± ± 00 Ta=70 C : 0 ~ ± 500 Ta=70 C : 0 ~ ± ± 00 Ta=70 C : 0 ~ ± 500 Ta=70 C : 0 ~ 0 Insulation voltage V D C 800V / min. Temperature variation Reaction time to 0 % of I PN step Reaction time to 90 % of I PN step di/dt accurately followed Frequency bandwidth ( db) mbient Operating temperature mbient storage temperature Secondary coil resistance m ns khz C C Ω Typ. ± 0., ax. ± 0.7 ( 0 C C) / Typ. ± 0., ax. ± 0. ( 0 C C) < 500 < (With a di/dt of 00 /µs.) > 00 DC (@Ta=70 C) / (@Ta=85 C) ass g 95 Standards EN 5078: 997 / IEC : 000 ±.. 0 6(@ ±0V) + I S ± 0.5 < 0. ax. ± 0. JPC00T 80069[600C(0)] olex Ta=85 C : 0 ~ 5 Ta=85 C : 0 ~ 8 Ta=85 C : 0 ~ 5 Ta=85 C : 0 ~ 9 Ta=85 C : 0 ~ 86 Ta=85 C : 0 ~ 8 ax. ± 0. (@ I P, after an overload of x I PN )

13 ClosedLoop Current Sensor JPC00X Panel Dimensions(mm) JPC00F IP + IS Rm 0V +Vc Vc NC R Current Direction anufacturer Part Number Old Part Number olex Primary throughhole Ø 0. mm Detail JPC00T IS Rm I P + 0V +Vc Vc R B 56.5 anufacturer Part Number Old Part Number olex C (0) Primary throughhole Ø 0. mm Detail B

14 Panel ClosedLoop Current Sensor JPC500X For the electronic measurement of currents : C/DC current sensor, JPC series has good stability in high currents and a highly insulated primary and secondary. dvantages Excellent accuracy Very good linearity Low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference Current overload capability. pplications C variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched ode Power Supplies (SPS) Power supplies for welding applications. Features Closed loop (compensated) current transducer using the Hall effect Insulated plastic case recognized according to UL 9V0 Panel mounting Specification ODEL SPEC JPC500F JPC500T 98800[556600] olex 80069[600C(0)] olex Primary nominal current rms Primary current, measuring range easuring Ω ± ± ± ~ ± ~ ± ± ~ ± ~ 0 ± ± ~ ± ~ 65 Secondary nominal current rms Conversion ratio Supply voltage (+ 5 %) Current ± 5 V Overall accuracy Linearity error Offset current m V m % % m 00 : 5000 ± 5.. (@ ±8V) + I S ± 0.6 < 0. ax. ± 0. agnetic offset current m ax. ± 0. (@ I P = 0 and specified R, after an overload of x I PN ) Insulation voltage V D C 800V / min. Temperature variation Reaction time to 90 % of I PN step di/dt accurately followed Frequency bandwidth ( db) mbient Operating temperature mbient storage temperature Secondary coil resistance m μs /μs khz C C Ω Typ. ± 0., ax. ± 0. ( 0 C C) < (With a di/dt of 00 /µs.) > 00 DC (@Ta=70 C) ass g 0 Standards EN 5078: 997 / IEC 600

15 ClosedLoop Current Sensor JPC500X Panel Dimensions(mm) JPC500F IP + IS Rm 0V +Vc Vc NC R anufacturer Part Number Old Part Number olex Primary throughhole Ø 0. mm Detail JPC500T IP + IS Rm 0V +Vc Vc R B anufacturer Part Number Old Part Number olex C (0) Primary throughhole Ø 0. mm Terminal No. Detail B 5

16 Panel ClosedLoop Current Sensor JPC000X For the electronic measurement of currents : C/DC current sensor, JPC series has good stability in high currents and a highly insulated primary and secondary. dvantages Excellent accuracy Very good linearity Low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference Current overload capability. pplications C variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched ode Power Supplies (SPS) Power supplies for welding applications. Features Closed Loop (compensated) current transducer using the Hall effect Insulated plastic case recognized according to UL 9V0 Panel mounting Specification ODEL SPEC JPC000F JPC000T 98800[55660a0] olex 80069[600c(0)] olex Primary nominal current rms 000 Primary current, measuring range 0.. ± 500 easuring resistance Ω ± ± 000 Ta=70 C : 0 ~ 8 Ta=85 C : 0 ~ ± 00 Ta=70 C : 0 ~ 7 Ta=85 C : 0 ~ ± ± 000 Ta=70 C : 5 ~ 60.5 Ta=85 C : 0 ~ ± 500 Ta=70 C : 5 ~ Ta=85 C : 0 ~ Secondary nominal current rms m 00 Conversion ratio Supply voltage (+ 5 %) Current consumption ( ± mv ) Overall accuracy Linearity error Offset current V m % % m : 5000 ± 5.. 8(@ ±V) + I S ± 0. < 0. ax. ± 0. agnetic offset current m ax. ± 0.(@ I P = 0 and specified R, after an overload of x I PN ) Insulation voltage V D C 800V / min. Temperature variation Reaction time to 90 % of I PN step di/dt accurately followed Frequency bandwidth ( db) mbient Operating temperature mbient storage temperature Secondary coil resistance m μs /μs khz C C Ω Typ. ± 0., ax. ± 0.5 ( 0 C C) / ax. ± 0.8 ( 0 C.. 0 C) < (With a di/dt of 00 /µs.) > 00 DC (@Ta=70 C) / 5 (@Ta=85 C) ass g 550 Standards EN 5078: 997 / IEC 600 6

17 ClosedLoop Current Sensor JPC000X Panel Dimensions(mm) 0 00 JPC000F IP + IS Rm 0V +Vc Vc NC R anufacturer Part Number Old Part Number olex Primary throughhole 0.5 x mm or Ø 8 mm Detail JPC000T IP + IS Rm 0V +Vc Vc R B anufacturer Part Number Old Part Number olex C (0) Primary throughhole 0.5 x mm or Ø 8 mm Detail B Terminal No. 7

18 Panel ClosedLoop Current Sensor JPC000X For the electronic measurement of currents : C/DC current sensor, JPC series has good stability in high currents and a highly insulated primary and secondary. dvantages Excellent accuracy Very good linearity Low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference Current overload capability. pplications C variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched ode Power Supplies (SPS) Power supplies for welding applications. Features Closed loop (compensated) current transducer using the Hall effect Insulated plastic case recognized according to UL 9V0 Panel mounting Specification ODEL SPEC JPC000F JPC000T 98800[55660a0] olex 80069[600c(0)] olex Primary nominal current rms 000 Primary current, measuring range 0.. ± 000 easuring resistance Ω ± ± 000 Ta=70 C : 0 ~ 8 Ta=85 C : 0 ~ ± 00 Ta=70 C : 0 ~ 5 Ta=85 C : 0 ~ ± ± 000 Ta=70 C : 5 ~ 9 Ta=85 C : ~ ± 800 Ta=70 C : Ta=85 C : ± 000 Ta=70 C : 5 ~ Ta=85 C : Secondary nominal current rms m 00 Conversion ratio Supply voltage (+ 5 %) Current consumption ( ± mv ) Overall accuracy Linearity error Offset current V m % % m : 5000 ± 5.. (@ ±V) + I S ± 0. < 0. ax. ± 0.5 agnetic offset current m ax. ± 0.(@ I P = 0 and specified R, after an overload of x I PN ) Insulation voltage V D C 6000V / min. Temperature variation Reaction time to 90 % of I PN step di/dt accurately followed Frequency bandwidth ( db) mbient Operating temperature mbient storage temperature Secondary coil resistance m μs /μs khz C C Ω Typ. ± 0., ax. ± 0.5 ( 5 C C) / ax. ±.5 ( 0 C.. 5 C) < (With a di/dt of 00 /µs.) > 50 DC (@Ta=70 C) / 6 (@Ta=85 C) ass kg.5 Standards EN 5078: 997 / IEC 600 8

19 ClosedLoop Current Sensor JPC000X Panel Dimensions(mm) 70 5 JPC000F IP + IS Rm 0V +Vc Vc NC.5 R anufacturer Part Number Old Part Number olex Primary throughhole 60.5 x 0.5 mm or Ø max 57 mm Detail JPC000T IP + IS Rm 0V +Vc Vc.5 R B anufacturer Part Number Old Part Number olex C (0) Primary throughhole 60.5 x 0.5 mm or Ø max 57 mm Detail B Terminal No. 9

20 Panel OpenLoop Current Sensors JHOXXXG(/B) Series Features Panel mounting Industrial temperature range UL9V0 compliance CE and RoHS available Specification * Suffix(X)=/B ODEL Rating current Saturation current Output voltage Offset voltage JHO 050G(X) 50 50T ±0 mv max Less than JHO 075G(X) 75 5T JHO 00G(X) 00 00T JHO 50G(X) JHO 00G(X) JHO 00G(X) T 600T ± V, % at rated current RL=0KΩ ±5 mv max JHO 00G(X) T JHO 500G(X) 500 ±50 mv max JHO 600G(X) 600 Output linearity Power supply Di/dt response time Output temperature character Offset voltage temperature character Hysteresis error Insulation withstand voltage Insulation resistance Frequency bandwidth Operating Condition Storage Condition ± mv/ C 0mV Less than 0mV ±% rated current ±5 V (±5%) 0m μ sec (Typ.) at di/dt = F.S/μ Sec. ± 0.% / C (Typ.) ± mv / C (Typ.) 5mV(IF=F.S) Less than 5mV C 500V / min. DC 500V / 500Ω max 0kHz 5 C~+80 C 5 C~+85 C Dimension Connection JHOXXXG JHOXXXGB OLEX 5050G or GEOYOUNG LPH Ø If OLEX 5050G or GEOYOUNG LPH Ø If GND +V CC V CC R L =0kΩ V OUT Ø Ø Terminal Pin Function + 5V 5V Output 0 V Unit : mm [inch] Core=Silicon steel plate 0

21 OpenLoop Current Sensors JHOXXXC(/B) Series Panel Specification Features Panel mounting Industrial temperature range Designed for roundwire, output connector type UL9V0 compliance CE and RoHS available Two different size ( : Ø / B : 0Ø) * Suffix(X)=/B ODEL Rating current Saturation current Output voltage Offset voltage JHO 050C(X) 50 50T ±0 mv max Less than JHO 075C(X) 75 5T JHO 00C(X) 00 00T JHO 50C(X) JHO 00C(X) T 600T ± V, % at rated current RL=0KΩ ±5 mv max JHO 00C(X) JHO 00C(X) T JHO 500C(X) 500 ±50 mv max JHO 600C(X) 600 Output linearity Power supply Di/dt response time Output temperature character Offset voltage temperature character Hysteresis error Insulation withstand voltage Insulation resistance Operating Condition Storage Condition ± mv/ C 0mV Less than 0mV ±% rated current ±5 V (±5%) 0m μ sec (Typ.) at di/dt = F.S/μ Sec. ± 0.% / C (Typ.) ± mv / C (Typ.) 5mV(IF=F.S) Less than 5mV C 500V / min. DC 500V / 500Ω max 5 C~+80 C 5 C~+85 C Dimension Connection JHOXXXC JHOXXXCB Ø OLEX 5050G or GEOYOUNG LPH00 If Ø0 OLEX 5050G or GEOYOUNG LPH00 If +V CC R L =0kΩ V CC GND V OUT Ø.5 Ø Unit : mm [inch] Terminal Pin Function Core=Silicon steel plate + 5V 5V Output 0 V

22 Panel OpenLoop Current Sensors JHOXXXXD Series Features Panel mounting Industrial temperature range UL9V0 compliance CE and RoHS available Specification * Suffix(X)=/B ODEL Rating current Saturation current Output voltage JHO 00D(X) ±00 ±600 JHO 00D(X) ±00 ±00 JHO 500D(X) ±500 ±500 JHO 600D(X) JHO 750D(X) JHO 800D(X) JHO 000D(X) JHO 00D(X) ±600 ±750 ±800 ±000 ±00 ±800 ±50 ±00 ±000 ± V, % at rated current RL=0KΩ JHO 500D(X) ±500 Offset voltage ±0 mv Output linearity Power supply Di/dt response time Output temperature character Offset voltage temperature character Hysteresis error Insulation withstand voltage Insulation resistance Operating Condition Storage Condition ±% rated current ±5 V (±5%) 7 μ sec (Typ.) at di/dt = F.S/μ Sec. ± 0.% / C (Typ.) ± mv / C (Typ.) 5mV(IF=F.S) Less than 5mV C 500V / min. DC 500V / 500Ω max 0 C ~ +05 C 0 C ~ +5 C Dimensions(unit : mm) 89 Connection R. Ø Ø V CC R L =0kΩ V CC OFS GND V OUT Terminal Pin Function Core=Silicon steel plate + 5V 5V Output 0 V

23 OpenLoop Current Sensors JXHXXXXXX Series Split Core Panel Din Rail Splitcore current transducer for the electronic measurement of DC or C waveform currents, with galvanic isolation between the primary circuit and the secondary circuit (measurement). TrueRS outputs proportional to the primary current: Either 05V DC or ctive Current Source 0m DC. ain characteristics pplications Features dvantages Current transformer and RS circuit in a single case Choice of primary current ranges: 5 to 50 RS Choice of standard output types: 0m, 05V ccuracy: <% of nominal primary current Bandwidth: khz utomation and Supervision Safety and Condition onitoring HVC & Pumps Refrigeration Small Industrial otors Fans Lighting TrueRS (Bipolar DC in => Unipolar DC out) ctive 05V DC output or ctive 0m output Single power supply (V) Operating range: 0 C to +60 C Isolation test voltage :.5kV RS / 50Hz / min Sensing aperture : mm UL9V0 recognized materials High isolation between primary and secondary circuits Compact case Easy installation Specification Rated Current () 5, 0, 0, 5, 50, 75, 00, 50, 00, 50 odel Output Electrical Data JXHXXXV 05V DC JXHXXXRS 0m DC Linear DC voltage output (TrueRS) ctive Current Source output (TrueRS) cc essory O ption DIN RIL OUNTING ount the bracket on the rail and install current transformer Dimensions (unit : mm) Dimensions (unit : mm) PNEL OUNTING Tighten screws on the hole to mount bracket and install current transformer O G Relay cable(common) (attached with CT) PartNO. : 5600(red) Dimensions (unit : mm) Power supply : VDC O : Output G : GND ± 50 WG #8 C/DC (INPUT) DC(OUTPUT)

24 OpenLoop Current Sensors JSXXXHXXX Series Split Core On Primary Fastening How to use P P JS0 / 6 / / 6 XH Hall Sensor series, applying with accurate laminating core split technology and Open Loop technology isst OPEN HCS, JSXXXH Series designed for strong durability and improves both existed error in low current and error occurred by external vibration and shock to minimize tolerance on cutting cross section of core. s compact onetouch split structure, it offers best solution for security and fast installation on high frequency monitoring device instead of cutting power line. Rated current is DC5500, it satisfies with accuracy.0 and it certifies with security accreditation IEC600, UL600 and EN600 as offcial document. Features Caution Core s hysteresis occurs O point variation in proportion to its volume after over current. Output value includes each variation points so we recommend that actual range as over 5% space than rating, not over max current consecutively. One touch clamp structure Isolation measurement ± 5V(5m) power supply Specification ODEL Rating current Saturation current Output voltage Noise level Output linearity Power supply di/dt response time Output temperature character Insulation withstand voltage Insulation resistance Operating Condition Storage Condition JS0NH JS0NH JS0NH JS0NH JS0NH JS0NH JS6NH JS6NH JSNH JSNH JSSH JSSH JS6SH JS6SH JS6NH JS6NH JS6NH JS6NH JS6NH JS6NH T 0 5T 5.5T 0 0T 5 7.5T T.5T 50T 5T 50T ± V, % at rated current RL=0KΩ ±0 mv max Less than < 0mVpp ±% rated current ±5 V (±5%) 5m μ sec (Typ.) at di/dt = F.S/μ Sec. ± 0.% / C (Typ.) 50 65T ±0 mv max < 0mVpp ± 0.% / C (Typ.) C 500V / min. DC 500V / 500Ω max 5 C~+75 C, 85 % RH noncondensing 5 C~+90 C, 85 % RH noncondensing 00 65T 00 65T T

25 OpenLoop Current Sensors JSXXXHXXX Series Split Core On Primary Fastening Dimension D E C Unit : mm Ød odel B C D E Ød J S 0 X H XXX J S 6 X H XXX B J S X H XXX J S 6 X H XXX Graph 8 Output Voltage Characteristic Frequency Characteristic (lo=5) (V) (mv) lo () Output Wave [Hz] Output Wave 0/div 0/div V/div V/div Connection Diagram OV 5V (CO) +5V Red Green White Black CO INPUT Prɪˈsɪʒən Lachesis 5

26 Split Core On Primary Fastening Open Loop technology PQCT JPSXXH Series How to use JPSH00 00:±VDC JPSH00 00:±VDC P P JPS0 / 0 / / 5H Hall Sensor series, applying with accurate laminating core split technology and Open Loop technology PQCT OPEN JPSXXH Series designed for strong durability and improves both existed error in low current and error occurred by external vibration and shock to minimize tolerance on cutting cross section of core. s compact onetouch split structure, it offers best solution for security and fast installation on high frequency monitoring device instead of cutting power line. Rated current is DC500, it satisfies with accuracy.0 and it certifies with security accreditation IEC600, UL600 and EN600 as official document. pplications Power etering. Submetering for Building; Energy efficiency monitoring, consumption analysis, and cost allocation. Power Quality onitoring for Distribution System Equipment. Condition onitoring for Conveyers, Pumps, etc. Hybrid Inverter for Home Energy Storage. Distributed easurement Systems. Specification Features PC spring, secure locking hinge, onetouch structure make easy to install to the existent equipments such as a power distribution boards. Isolated plastic case recognized according to UL9V0 Benefits Smallsize, lightweight Simple Installation OverVoltage protection circuit is installed. ODEL Rating current Saturation current Output voltage JPS0H T JPS0H T JPS0H T JPS0H T JPS0H T JPS0H 050 JPS0H T JPS0H JPS0H JPSH JPSH JPSH JPS0H JPS0H JPS0H 50 JPS0H JPS0H JPS5H T 50T 5T 50T 65T 65T ± V, % at rated current RL=0KΩ ±0 mv max Less than (JPS0H) ±0 mv max ( JPS0H, JPSH, JPS5H ) JPSH 00 JPS5H T JPSH 500 JPS5H JPS5H 600 JPS5H 800 JPS5H 000 JPS5H T 900T 00T 00T 00T Noise level Output linearity Power supply di/dt response time Output temperature character Insulation withstand voltage Insulation resistance Operating Condition Storage Condition < 0mVpp (JPS0H) < 0mVpp ( JPS0H, JPSH, JPS5H ) ±% rated current ±5 V (±5%) 5m μ sec (Typ.) at di/dt = F.S/μ Sec. ± 0.% / C (Typ.) ± 0.% / C (Typ.) C 000V / min. DC 500V / 500Ω max 5 C~+75 C, 85 % RH noncondensing 5 C~+90 C, 85 % RH noncondensing 6

27 OpenLoop technology PQCT JPSXXH Series Split Core On Primary Fastening Dimension D Unit : mm odel B C D E J P S 0 H X X X C E J P S 0 H X X X J P S H X X X B J P S 5 H X X X Graph 8 Output Voltage Characteristic Frequency Characteristic (lo=5) (V) (mv) lo () Output Wave [Hz] Output Wave 0/div 0/div V/div V/div Connection Diagram OV 5V (CO) +5V Red Green White Black CO INPUT 7

28 Split Core Panel OpenLoop Current Sensors JHOXXXXSD(/B) Series Features Panel mounting Industrial temperature range UL9V0 compliance CE and RoHS available Specifi cation ODEL Rating current Saturation current Output voltage JHO 000SD(X) JHO 500SD(X) JHO 000SD(X) JHO 500SD(X) JHO 000SD(X) ± V, 0.5% at rated current RL=0KΩ JHO 000SD(X) JHO 5000SD(X) ±000 ±500 ±000 ±500 ±000 ±000 ±5000 ±000 ±000 ±000 ±5000 ±6000 ±8000 ±8000 ±0 mv Output linearity Power supply Di/dt response time Output temperature character ±0.5% rated current ±5 V (±5%) ± 0.% / C (Typ.) temperature character ± mv / C (Typ.) Hysteresis error 5mV(IF=F.S) Less than 5mV Insulation withstand voltage Insulation resistance Operating Condition Storage Condition C 000V / min. DC 500V / 500Ω max 0 C ~ +70 C 5 C ~ +85 C Dimensions(unit : mm) Connection 0 5 Ø Ø V CC R L =0kΩ V CC Detail 06 Detail B GND Terminal Pin Function + 5V V OUT 5V Output 0 V Terminal No. Core=Silicon steel plate

29 ClosedLoop Voltage Sensor JHVC5 PCB HT +HT JHVC5 + Features Excellent accuracy and linearity Low response time thermal drift High tolerance to external interference High bandwidth Specification odel Nominal input easuring range easuring resistor (Vs = ±...5V) Output current(im) ccuracy (Ta=+5 C) Turns ratio Supply voltages(vs) Current consumption Isolation voltage Offset current (Ta=+5 C) Temperature drift Linearity Response time Operating Frequency range Operating temperature Storage temperature Secondary resistor Primary resistance Weight JHVC5 0mrms (0V...500V) 0~±m ±0m : 0Ω ~ ±m : 0Ω ~ 00Ω ±5m IN±.0% 500:000 ±V~±5V (±5%) 0m+Im.5kV RS/ 50Hz/min. ±0.m ax for primary current IN=0 ±0.m Typical; ±0.m ax (0 C~+70 C) < 0.% < 0μs 0~0kHz 0 C~+70 C 0 C~+85 C 0Ω (Ta=+70 C) 50Ω (Ta=+70 C) g ±0m : 00Ω ~ ±m : 00Ω ~ 90Ω Dimensions(unit : mm) Connection Ø0. +V N X HT HT I N Primary current R HT +HT +HT HT JHVC5 JD R N + 0V V N 9

30 Panel Digital Voltage Sensor EVS0XXXXX Series Voltage transducer uses special Isolation Barrier technology to measure C and DC or Pulsed voltages. The primary input voltage and the output signal is highly electric isolated. It can be used in Power Utility, Converters, Traction, Telecom, Oil & Gas, and New energy fields. Features C, DC, Pulsed voltage measurement Included primary resistor Good linearity Galvanic isolation between primary and secondary circuit Low power consumption High immunity to external interference Low thermal drift Higher voltage can measure than EVS0 Electrical characteristics Primary nominal voltage (Vrms) Primary voltage, measuring range (Vrms) Secondary Current output Secondary Voltage output ccuracy (Ta=+5 C) Linearity error Power supply voltage (± 5V) Offset current (T = +5 C) Response time Frequency bandwidth V PN V P I SN V SN X G ε L V C I 0 T R 50, 5, 50, 50, 500, 750, 000, 500, 000, 500, 000 V 50% x VPN 50 m (EVS0XXXX) 0 ± 5V (EVS0XXXXV) 0.5% 0.% PN (± 5%) ± 0.5 m 0 μs DCKHZ(dB) f Current consumption I C 50m (for current output: + IS ) Load resistance R L 50Ω(for current output) or >5KΩ(for voltage output) Primary input resistance R P 60Ω Isolation test (50Hz,min) 6.0 kv V D General data mbient operating temperature mbient storage temperature ass Standards mbient operating humidity Case material T T S W S T H 0 C C 50 C C * 50g EN % RH ccording to UL9V0 0

31 Digital Voltage Sensor EVS0XXXXX Series Panel Dimensions (mm) Ø H+ H + E General tolerance ± mm Terminals Input : x 5 Output : x 5 Fastening Bottom: x Ø 6.5(mm) Side : x Ø.8(mm) 5. Connection diagram Output figure 0 ± 5V (EVS0XXXXV) 50 m (EVS0XXXX) Output in V Output in m HV + Is Rm +Vc 0 V HV Vc V PN 0 + V PN V PN 0 + V PN Isolation barrier 5 0±5V output 50 0±50m output

32 Panel Digital Voltage Sensor EVS0XXXX series Voltage transducer uses special Isolation Barrier technology to measure C and DC or Pulsed voltages and True RS treatment, the output signal can be standard RS voltage or current. The primary input voltage and the output signal is highly electric isolated. It can be used in Power Utility, Converters, Traction, Telecom, Oil & Gas, and New energy fields. Features C, DC, Pulsed voltage measurement Included primary resistor Good linearity Galvanic isolation between primary and secondary circuit Low power consumption High immunity to external interference Low thermal drift Higher voltage can measure than EVS0 Electrical characteristics Primary nominal voltage (Vrms) Primary voltage, measuring range (Vrms) Secondary Current output Secondary Voltage output ccuracy (Ta=+5 C) Linearity error Power supply voltage (± 5%) current (T = +5 C) Response time Frequency bandwidth Current consumption Load resistance Isolation test (50Hz,min) VPN VP ISN VSN XG εl VC I0 TR f IC RL VD 50, 50, 50, 500, 000, 500, 000, 500, 000 V 50% x VPN DC00m, DC0m DC05V, DC00V 0.5% 0.% Vdc 50mV / ±0.08m 50mS DC,0HZKHZ(dB) 50m (for current output + Is) 50Ω(for current output) or >5KΩ(for voltage output) 6.0 kv General data mbient operating temperature mbient storage temperature ass Standards mbient operating humidity Case material T TS W ST H 0 C C 50 C C 50g EN % RH ccording to UL9V0

33 Digital Voltage Sensor EVS0XXXX series Panel Dimensions (mm) Ø H+ H + E General tolerance ± mm Terminals Input : x 5 Output : x 5 Fastening Bottom: x Ø 6.5(mm) Side : x Ø.8(mm) 5. Connection diagram Output figure +HV + Is Rm +Vc 0 V DC0m output HV Vc Isolation barrier DC05V output DC00Voutput

34 Checklist for Customers Date Project name Company name pplication Demander (name/dept./position) nnual estimated Q'ty K pcs Location in. lot Q'ty K pcs Tel. Target price ( USC/ EUR/ JPY) Fax. Q'ty of samples required for pcs Q Requirement Contents pplication Nominal value Power supply di/dt to be followed Energy onitoring ( )rms ± ( )/ Current onitoring Other( ) + Preferred output Turns ratio ccuracy class Overload requirement m/ mv/ m/ mv/ Primary : Second ( : ( )% ( )% of ax. Primary Current Operating Temperature range in. ( ) ax. ( ) Operating Frequency ( )Hz Dielectric withstand 'ndearth C( )kv / min. Dimensions Primary Connection Terminal Structure Inner Dia. ( )mm, Width x Length x Height ( x x )mm Through hole Busbar Other PCB olex Cable Other requirements (if any, Diagram required for)

35 EO 5

36

DC CURRENT SENSOR DC VOLTAGE SENSOR

DC CURRENT SENSOR DC VOLTAGE SENSOR VC T JH H 0 5 tn o L /S P 0 0 5 5m 0 C 0 DC P : 5 V J 0 o : ±5 5 H T DC CURRENT SENSOR DC VOLTGE SENSOR J&D C/DC CTs provide noncontact detection of C/DC current. The C/DC CTs have two types of splitcore

More information

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L High Performance Current Transducer IT 200-S ULTRASTAB For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit and the secondary circuit. I PM

More information

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit. Voltage transducer V PN = 4 V Ref: DV 4/SP4 For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit. Features Bipolar and isolated

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer IT 200-S ULTRASTAB I PM = 200 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Closed loop (compensated)

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer IT 700-S ULTRASTAB I PM = 700 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Closed loop (compensated)

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NP series I PN = 4, 6, 12, 15 Ref: HO 4-NP, HO 6-NP, HO 12-NP, HO 15-NP For the electronic measurement of current: DC, C, pulsed..., with galvanic separation between the primary and

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer IN 1000-S I P N = 1000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed loop (compensated)

More information

AUTOMOTIVE CURRENT TRANSDUCER HC6F600-S

AUTOMOTIVE CURRENT TRANSDUCER HC6F600-S AUTOMOTIVE CURRENT TRANSDUCER HC6F600-S 18198102215 Page 1/5 Introduction Principle of HC6F Family The HC6F Family is for use on the electronic measurement of DC, AC or pulsed currents in high power and

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer IT 205-S ULTRASTAB I PN = 200 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Wide operating temperature

More information

= 1000 V. Voltage transducer DVC 1000-P V P N

= 1000 V. Voltage transducer DVC 1000-P V P N Voltage transducer DVC 1-P V P N = 1 V For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer IN 1000-S N = 1000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed loop (compensated)

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer IT 605-S ULTRASTAB I PN = 600 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Wide operating temperature

More information

AUTOMOTIVE CURRENT TRANSDUCER HAH1DR 300-S

AUTOMOTIVE CURRENT TRANSDUCER HAH1DR 300-S AUTOMOTIVE CURRENT TRANSDUCER Introduction The HAH1DR family is for the electronic measurement of DC, AC or pulsed currents in high power automotive applications with galvanic isolation between the primary

More information

AUTOMOTIVE CURRENT TRANSDUCER HC6H1000-S

AUTOMOTIVE CURRENT TRANSDUCER HC6H1000-S AUTOMOTIVE CURRENT TRANSDUCER HC6H1000-S 18198151434 Page 1/ 5 HC6H1000-S Introduction Principle of HC6H Family The HC6H Family is for use on the electronic measurement of DC, AC or pulsed currents in

More information

High Performance Current Transducer ITL 900-T = A

High Performance Current Transducer ITL 900-T = A High Performance Current Transducer ITL 900-T For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. I PM = 0... 900 A Electrical

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer ITN 1000-S ULTRASTAB I PM = 1000 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Closed loop (compensated)

More information

AUTOMOTIVE CURRENT TRANSDUCER HC6F700-S

AUTOMOTIVE CURRENT TRANSDUCER HC6F700-S AUTOMOTIVE CURRENT TRANSDUCER HC6F700-S 18198102215 Page 1/5 Introduction Principle of HC6F Family The HC6F Family is for use on the electronic measurement of DC, AC or pulsed currents in high power and

More information

AUTOMOTIVE CURRENT SENSOR HC6H300-S

AUTOMOTIVE CURRENT SENSOR HC6H300-S AUTOMOTIVE CURRENT SENSOR HC6H300-S Page 1/ 5 Introduction Principle of HC6H Family The HC6H Family is for use on the electronic measurement of DC, AC or pulsed currents in high power and low voltage automotive

More information

AUTOMOTIVE CURRENT SENSOR HC6H500-S. Datasheet

AUTOMOTIVE CURRENT SENSOR HC6H500-S. Datasheet AUTOMOTIVE CURRENT SENSOR HC6H500-S Datasheet Page 1/ 5 Introduction Principle of HC6H Family The HC6H Family is for use on the electronic measurement of DC, AC or pulsed currents in high power and low

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current transducer LF 210-S/SP3 I PN = 100 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated

More information

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Voltage transducer DV V PN = V For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Applications Bipolar and insulated

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer IT 700-SB ULTRASTAB I PM = 700 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features ± 10 V voltage output

More information

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit. Voltage transducer V PN = 1 V Ref: DV 1/SP For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit. Features Bipolar and isolated

More information

Current Transducer CTSR 1-P = 1A

Current Transducer CTSR 1-P = 1A Current Transducer CTSR 1-P I PRN = 1A For the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation between the primary (high power) and the secondary circuit (electronic circuit).

More information

V P N. Voltage transducer DVM 2000-B = 2000 V

V P N. Voltage transducer DVM 2000-B = 2000 V Voltage transducer DVM 2-B V P N = 2 V For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current transducer LF 510-S/SP13 I PN = 500 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current transducer LF 510-S I PN = 500 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated

More information

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit. Voltage transducer DVL 15 V PN = 15 V For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit. Features Bipolar and isolated

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current transducer LF 2010-S I PN = 2000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NSM- SERIES I PN = 8, 15, 25 A Ref: HO 8-NSM-, HO 15-NSM-, HO 25-NSM- For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and

More information

= 600 V. Voltage transducer DVM 600 V PN

= 600 V. Voltage transducer DVM 600 V PN Voltage transducer DVM 6 V PN = 6 V For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NSM/SP33 series N = 8, 15, 25 A Ref: HO 8-NSM/SP33, HO 15-NSM/SP33, HO 25-NSM/SP33 For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the

More information

Technical catalogue. Current sensors Voltage sensors

Technical catalogue. Current sensors Voltage sensors Technical catalogue Current sensors Voltage sensors Current sensors Voltage sensors Contents Technologies Current measuring technology... 4 Voltage measuring technology... 8 Voltage detection technology...

More information

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S00

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S00 AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S00 Introduction The HAH3DR family, a tri-phase tranducer is for the electronic measurement of DC, AC or pulsed s in high power automotive applications with galvanic

More information

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Voltage transducer DV 42/SP3 V P N = 42 V For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current transducer ITC 2000-S/SP2 N = 2000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated

More information

Ref: HO 50-S/SP33, HO 100-S/SP33, HO 150-S/SP33, HO 200-S/SP33, HO 250-S/SP33

Ref: HO 50-S/SP33, HO 100-S/SP33, HO 150-S/SP33, HO 200-S/SP33, HO 250-S/SP33 Current Transducer HO-S/SP33 series I PN = 50, 100, 150, 200, 250 A Ref: HO 50-S/SP33, HO 100-S/SP33, HO 150-S/SP33, HO 200-S/SP33, HO 250-S/SP33 For the electronic measurement of current: DC, AC, pulsed...,

More information

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Voltage transducer DV 64 V P N = 64 V For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit. Current Transducer CASR series I PN = 6, 5, 25, 5 A Ref: CASR 6-NP, CASR 5-NP, CASR 25-NP, CASR 5-NP For the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation between the primary

More information

Voltage transducer DVL 50

Voltage transducer DVL 50 Voltage transducer DVL 5 V PN = 5 V For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit. Features Bipolar and isolated measurement

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer LF 2010-S/SPA7 I P N = 2000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and

More information

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 1100-S07

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 1100-S07 AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY Introduction The HAH3DR-S07 family is a tri-phase transducer for DC, AC, or pulsed currents measurement in automotive applications. It offers a galvanic

More information

V P N. Voltage transducer DVM 4200 = 4200 V

V P N. Voltage transducer DVM 4200 = 4200 V Voltage transducer DVM 42 N = 42 V For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated measurement

More information

Data Sheet. Hall effect transducers, current and voltage

Data Sheet. Hall effect transducers, current and voltage Data Pack E Issued March 200 232-20 Data Sheet Hall effect transducers, current and voltage This data sheet covers the following products: RS stock no. Type of transducer 28-3 Multi-range current, PCB

More information

Unipolar voltage - Current output 4-20 ma Ref: DVL 50-UI, DVL 150-UI, DVL 250-UI, DVL 500-UI, DVL 750-UI, DVL 1000-UI, DVL 1500-UI

Unipolar voltage - Current output 4-20 ma Ref: DVL 50-UI, DVL 150-UI, DVL 250-UI, DVL 500-UI, DVL 750-UI, DVL 1000-UI, DVL 1500-UI Current Transducer DVL-UI series V PN = 50... 1500 V Unipolar voltage - Current output 4-0 ma Ref: DVL 50-UI, DVL 150-UI, DVL 50-UI, DVL 500-UI, DVL 750-UI, DVL 1000-UI, DVL 1500-UI For the electronic

More information

I P I OUT R L. Applications. Standards. N 52.D ; Page 1/8

I P I OUT R L. Applications. Standards. N 52.D ; Page 1/8 Ref: ATO-10-B225-D10/SP3 r = 10 A ATO series is a split core current transformer for the electronic measurement of AC waveform current with galvanic separation between the primary circuit (power) and the

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and secondary circuit. Current Transducer LF 510-S I P N = 500 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and secondary circuit. Features Bipolar and insulated

More information

Technical catalog. Current sensors Voltage sensors. Contact John G Peck Ltd - jgpl.com

Technical catalog. Current sensors Voltage sensors. Contact John G Peck Ltd - jgpl.com Technical catalog Current sensors Voltage sensors Current sensors Voltage sensors Technologies Current measuring technology 4 Voltage measuring technology 8 Voltage detection technology 10 Glossary 12

More information

CYHCS-RC2S Split Core Hall Effect DC Current Sensor

CYHCS-RC2S Split Core Hall Effect DC Current Sensor Current Sensors CYHCS-RC2S Split Core Hall Effect DC Current Sensor This Hall Effect current sensor can be used for measurement of DC and AC current, pulsed currents etc. The output of the transducer reflects

More information

AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS

AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS AUTOMOTIVE CURRENT TRANSDUCER HCF-SN CLIPS Introduction The HCF CLIPS Family is for the electronic measurement of DC, AC or pulsed currents in high power and low voltage automotive applications with galvanic

More information

Mors Smitt Industrial Technology. Industrial current & voltage sensors. Hall effect current & voltage sensors

Mors Smitt Industrial Technology. Industrial current & voltage sensors. Hall effect current & voltage sensors Mors Smitt Industrial Technology Industrial current & voltage sensors Hall effect current & voltage sensors Mors Smitt Industrial Technology Industrial sensors Industrial current & voltage sensors Closed

More information

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DR 200-S

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DR 200-S AUTOMOTIE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAHDR 2-S Introduction The HAHDR family is for the electronic measurement of DC, AC or pulsed currents in high power automotive applications with galvanic

More information

HC2F100-SN CLIPS AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS. Datasheet

HC2F100-SN CLIPS AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS. Datasheet AUTOMOTIVE CURRENT TRANSDUCER Datasheet 071113/1 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. Page 1/ 6 www.lem.com Introduction

More information

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DRW 300-S

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DRW 300-S AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY Introduction The HAH1DRW family is for the electronic measurement of DC, AC or pulsed currents in high power and low voltage automotive applications with

More information

HO 50-S/SP30, HO 100-S/SP30, HO 150-S/SP30, HO 200-S/SP30, HO 250-S/SP30 and HO 200-S/SP31

HO 50-S/SP30, HO 100-S/SP30, HO 150-S/SP30, HO 200-S/SP30, HO 250-S/SP30 and HO 200-S/SP31 Current Transducer HO-S/SP3 series Ref: I PN = 5,, 15, 2, 25 A HO 5-S/SP3, HO -S/SP3, HO 15-S/SP3, HO 2-S/SP3, HO 25-S/SP3 For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current transducer CKSR series N = 6, 5, 25, 5 A Ref: CKSR 6-NP, CKSR 5-NP, CKSR 25-NP, CKSR 5-NP For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer LF 2010-S/SPA0 I P N = 2000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and

More information

V P N. Voltage transducer DVL 1000 = 1000 V

V P N. Voltage transducer DVL 1000 = 1000 V Voltage transducer DVL 1 V P N = 1 V For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current transducer LF 1010-S/SPA2 I PN = 1000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and

More information

Technical Catalogue. Current Sensors Voltage Sensors

Technical Catalogue. Current Sensors Voltage Sensors Technical Catalogue Current Sensors Voltage Sensors Current Sensors Voltage Sensors Table of contents Technologies Current measuring technology... 4 Voltage measuring technology... 8 Voltage detection

More information

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S02

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S02 AUTOMOTIVE CURRENT TRANSDUCER Introduction The HAH3DR family, a tri-phase tranducer is for the electronic measurement of DC, AC or pulsed s in high power automotive applications with galvanic isolation

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. Current Transducer CTSR 0.6-TP/SP2 I PRN = 600 ma For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. Features

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer ITL 4000-S I PN = 4000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. I > 0 P Features Closed

More information

SPECIFICATION Item no.: T60404-N4646-X400

SPECIFICATION Item no.: T60404-N4646-X400 Customer: Standard type Customers Part no.: Page 1 of 5 Description Closed loop (compensation) Current Sensor with magnetic field probe Printed circuit board mounting Casing and materials UL-listed Electrical

More information

Ref: HLSR 10-P/SP3, HLSR 20-P/SP3, HLSR 40-P/SP3, HLSR 50-P/SP3

Ref: HLSR 10-P/SP3, HLSR 20-P/SP3, HLSR 40-P/SP3, HLSR 50-P/SP3 Current Transducer HLSR-P/SP3 series N = 10... 50 A Ref: HLSR 10-P/SP3, HLSR 20-P/SP3, HLSR 40-P/SP3, HLSR 50-P/SP3 For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation

More information

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017 Ref: ART-B22-D70, ART-B22-D125, ART-B22-D175, ART-B22-D300 Flexible clip-around Rogowski coil for the electronic measurement of AC current with galvanic separation between the primary circuit (power) and

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer N = 6, 15, 25, 5 A Ref: LESR 6-NP, LESR 15-NP, LESR 25-NP, LESR 5-NP For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the

More information

I PN. Ref: HO 50-S, HO 100-S, HO 150-S, HO 200-S, HO 240-S, HO 250-S

I PN. Ref: HO 50-S, HO 100-S, HO 150-S, HO 200-S, HO 240-S, HO 250-S Current Transducer HO-S series I PN = 50, 100, 150, 200, 240, 250 A Ref: HO 50-S, HO 100-S, HO 150-S, HO 200-S, HO 240-S, HO 250-S For the electronic measurement of current: DC, AC, pulsed..., with galvanic

More information

Ref: HLSR 10-SM, HLSR 16-SM, HLSR 20-SM, HLSR 32-SM, HLSR 40-SM, HLSR 50-SM

Ref: HLSR 10-SM, HLSR 16-SM, HLSR 20-SM, HLSR 32-SM, HLSR 40-SM, HLSR 50-SM Current Transducer HLSR-SM series N = 1... 5 A Ref: HLSR 1-SM, HLSR 16-SM, HLSR 2-SM, HLSR 32-SM, HLSR 4-SM, HLSR 5-SM For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation

More information

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012 Ref: ART-B22-D70, ART-B22-D125, ART-B22-D175 Flexible clip-around Rogowski coil for the electronic measurement of AC current with galvanic separation between the primary circuit (power) and the secondary

More information

Ref: HLSR 10-SM/SP33, HLSR 20-SM/SP33, HLSR 32-SM/SP33, HLSR 40-P/SP33, HLSR 50-SM/SP33

Ref: HLSR 10-SM/SP33, HLSR 20-SM/SP33, HLSR 32-SM/SP33, HLSR 40-P/SP33, HLSR 50-SM/SP33 Current Transducer HLSR-SM/SP33 series I PN = 10... 50 A Ref: HLSR 10-SM/SP33, HLSR 20-SM/SP33, HLSR 32-SM/SP33, HLSR 40-P/SP33, HLSR 50-SM/SP33 For the electronic measurement of current: DC, AC, pulsed...,

More information

AUTOMOTIVE CURRENT SENSOR DHAB S/18. Datasheet

AUTOMOTIVE CURRENT SENSOR DHAB S/18. Datasheet AUTOMOTIVE CURRENT SENSOR DHAB S/18 Datasheet 070720/1 Page 1/6 Introduction The DHAB family is best suited for DC, AC or pulse current measurement in high power and low voltage automotive applications.

More information

AUTOMOTIVE CURRENT SENSOR DHAB S/25. Datasheet

AUTOMOTIVE CURRENT SENSOR DHAB S/25. Datasheet AUTOMOTIVE CURRENT SENSOR DHAB S/25 Datasheet Page 1/6 Introduction The DHAB family is best suited for DC, AC or pulse current measurement in high power and low voltage automotive applications. It s contains

More information

AUTOMOTIVE CURRENT TRANSDUCER DHAB S/15

AUTOMOTIVE CURRENT TRANSDUCER DHAB S/15 AUTOMOTIVE CURRENT TRANSDUCER Introduction The DHAB family is best suited for DC, AC, or pulsed currents measurement in high power and low voltage automotive applications. Its contains galvanic isolation

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer LESR series N = 6, 15, 25, 5 A Ref: LESR 6-NP, LESR 15-NP, LESR 25-NP, LESR 5-NP For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary

More information

I Pr I P I OUT R L. Applications. Standards

I Pr I P I OUT R L. Applications. Standards Ref: ATO-XXX-B225-D10 I Pr = 10, 15, 16, 20, 30, 32, 50, 60, 63, 75 A ATO series is a split core current transformer for the electronic measurement of AC waveform current with galvanic separation between

More information

ULTRASTAB I U Precision

ULTRASTAB I U Precision ULTRASTAB 867-700I 867-700U Precision Current Transducer The Ultrastab 867-700I and 867-700U Current Transducers, are the latest models of the Ultrastab Current Transducers. They are the third generation

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer LF 1010-S/SPA5 I P N = 1000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer CAS 25-NP/SP2 N = 25 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed loop (compensated)

More information

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 800-S03/SP2

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 800-S03/SP2 AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY Introduction The HAH3DR-S03 family is a tri-phase transducer for DC, AC, or pulsed currents measurement in high power and low voltage automotive applications.

More information

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/157

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/157 AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/157 Introduction The DHAB family is best suited for DC, AC, or pulsed currents measurement in high power and low voltage automotive applications.

More information

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/124

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/124 AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/124 Picture of product with pencil Introduction The DHAB family is best suited for DC, AC, or pulsed currents measurement in high power and low

More information

SPECIFICATION Item no.: T60404-N4646-X764

SPECIFICATION Item no.: T60404-N4646-X764 Customer: Standard type Customers Part no: Page 1 of 4 Description Closed loop (compensation) Current Sensor with magnetic field probe Printed circuit board mounting Casing and materials UL-listed Electrical

More information

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators. Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 3000A Features ppm linearity 0 ppm offset Current

More information

Current Sensor : F02P***S05L

Current Sensor : F02P***S05L Features: Backward compatible to F02PS***05 series Anti-Surge current (4kAT, 8/20uS, single) Mounting area reduced ; pin compatible. Longitudinal dimension reduced Super precision & High Stability (low

More information

I PM. Current Transducer ITZ 5000-SB FLEX ULTRASTAB = 5000 A

I PM. Current Transducer ITZ 5000-SB FLEX ULTRASTAB = 5000 A urrent Transducer ITZ 5000-SB FLEX ULTRASTAB I PM = 5000 A For ultra-high precision measurement of current: D, A, pulsed..., with galvanic separation between primary and secondary. Separate magnetic head

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer ITL 4000-S I P N = 4000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. I > 0 P Features Closed

More information

PRECISION CLAMP ON FLEXIBLE ROGOWSKI COIL CURRENT TRANSFORMER

PRECISION CLAMP ON FLEXIBLE ROGOWSKI COIL CURRENT TRANSFORMER JRF333M-X 333mVAC 24VDC, 2VA S1 S2 Vin + Vin - PRECISION CLAMP ON FLEXIBLE ROGOWSKI COIL CURRENT TRANSFORMER LED SINGLE PHASE output 333mV AC THREE PHASE output 333mV AC Power isast OPEN RCT is made with

More information

DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators. DL000ID Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 3000A Features ppm linearity 6 ppm offset

More information

DS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators

DS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 370A Features Linearity error maximum 2 ppm 100

More information

AUTOMOTIVE CURRENT TRANSDUCER HAB 60-S/SP5

AUTOMOTIVE CURRENT TRANSDUCER HAB 60-S/SP5 AUOMOIVE CURREN RANSDUCER HAB 60-S/SP5 Introduction he HAB Family is best suited for DC, AC or pulsed currents measurement in high power and low voltage automotive applications. It s contains galvanic

More information

L08P IPV/W/IPVW SERIES

L08P IPV/W/IPVW SERIES Magnetic Proportion System / Through Type L08P IPV/W/IPVW 1/3 2 1807 L08P IPV/W/IPVW SERIES ABSOLUTE MAXIMUM RATINGS Parameters Symbol Unit Supply voltage Vcc V 8V ISOLATION CHARACTERISTICS Symbol Unit

More information

DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators

DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 600A Features Linearity error maximum 1.5 ppm Fluxgate,

More information

RISH Ducer E13 3 channel transducer for AC current and voltage

RISH Ducer E13 3 channel transducer for AC current and voltage RISH Ducer E13 3 channel transducer for C current and voltage The RISH Ducer E13 ( Fig. 1) converts 3 sine wave C current or C voltage into 3 output signals that can serve several receiving instruments

More information

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HSW S01

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HSW S01 AUTOMOTIE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HSW S01 Introduction The HSW family is best suited for DC and AC currents measurement in high power and high voltage automotive applications. It features

More information

MSV200 - Hall effect transducer

MSV200 - Hall effect transducer - Hall effect transducer Datasheet Features Specially designed for railway applications Closed loop (compensated) High dielectric strength Precise linearity Precise accuracy High dynamic response No foucault

More information

ULTRASTAB IHF Precision Current Transducer

ULTRASTAB IHF Precision Current Transducer ULTRASTAB 867-200IHF Precision Current Transducer The Ultrastab 867-200IHF Current Transducer is a model in the Ultrastab Current Transducer program. It is the second generation of current transducers

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer LF 21-S/SPA2 I P N = 2 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated

More information

RISH Ducer E13 Transducer For Ac Current Or Ac Voltage With Different Characteristics

RISH Ducer E13 Transducer For Ac Current Or Ac Voltage With Different Characteristics RISH Ducer E13 Transducer For c Current Or c Voltage With Different Characteristics Data Sheet For Measurement of C Current or C Voltage Fig. 1. RISH Ducer E13 clipped onto a top - hat rail. Fig. 2. RISH

More information

Feed back element in high performance gradient amplifiers Feed back element in precision current regulated power supplies

Feed back element in high performance gradient amplifiers Feed back element in precision current regulated power supplies ULTRASTAB 866 Precision Current Transducer The Ultrastab 866 Current Transducer is the most proven fluxgate transducer with onboar electronics in the Danfysik Current Transducer program. It is the first