Parameter Value Unit Notes
|
|
- Jason Adams
- 5 years ago
- Views:
Transcription
1 Features Single axis measurement from ±5 to ±60 High resolution and accuracy. Low temperature drift, with optional temperature compensation to further improve temperature performance. RS232 and RS485 output versions. RS485 version with multi-drop networked ModBus protocol High precision robust corrosion resistant 316 Stainless Steel housing with IP67 sealing, and precision ground base CE and FCC certified and RoHS compliant. IP67 Sealed locking M8 connector Small size, 70 x 49 x 18mm Description The HPS series inclinometers are high performance inclination sensors designed for use in the toughest environments. There are a wide range of options to cover a measurement range from ±5 to ±60. The robust stainless steel housing is sealed to IP67 and utilises high performance sealed locking industry standard M8 connectors. The digital output can be selected as either RS232, RS485 or RS485 ModBus (for networked device connections). The device has inherently good temperature stability, but this can be improved further with optional temperature compensation over a range of different temperatures. The devices are CE and FCC certified and RoHS compliant. These devices are manufactured and calibrated in our UK factory to guarantee performance to the stated specification, and are built and configured to order on short lead times. General Specifications Parameter Value Unit Notes Supply Voltage RS232 Version RS485 Version V dc V dc Supply is filtered, suppressed and regulated internally, however we recommend the use of a low noise supply to prevent noise coupling to the sensor. Minimum supply of 12V is needed for RS485 version where terminating resistors are used. Operating Current 20 ma Maximum value at any operating voltage in range without RS485 terminating resistors. Operating Current 80 ma Maximum value when driving RS485 with 2 x 120Ω termination resistors Operating Temperature -40 to 85 C Maximum operating temperature range. Units can be calibrated between -20 and 70 C on request. RS232/485 Output Rate bps Bit rate is adjustable between 115.2k, 57.6k, 38.4k, 19.2k, 9.6k, 4.8k and 2.4k via the digital interface RS232 Data Format 38.4, 8,1,N 1 start bit, 8 data bits, 1 stop bit, no parity R485 ModBus Format 38.4, 8,1,N 1 start bit, 8 data bits, 1 stop bit, no parity Frequency 1 Hz This is the frequency at which the output is 3dB less than the input value. This is adjustable between 8Hz and 0.125Hz via the RS232/485 control commands Mechanical shock 5000 G Shock survival limit for internal sensor 5000G for 0.5ms Weight 350 g Not including cable Sealing IP67 - Seal rating applies to housing and cable gland. Gland is not designed for flexible cable installation, as this may compromise seal rating Page 1 of 14
2 Performance Specifications Parameter HPS-05 HPS-10 HPS-15 HPS-30 HPS-45 HPS-60 Unit Measuring range ±5 ±10 ±15 ±30 ±45 ±60 Zero Bias Error ±0.008 ±0.01 ±0.015 ±0.02 ±0.025 ±0.04 Accuracy C) ±0.01 ±0.015 ±0.02 ±0.025 ±0.04 ±0.05 Temperature Errors (without compensation) Zero Drift Sensitivity Drift ±0.003 ±0.013 ±0.003 ±0.013 ±0.003 ±0.013 ±0.003 ±0.013 ±0.008 ±0.014 ±0.008 ±0.014 / C %/ C Temperature Errors (with compensation) Zero Drift Sensitivity Drift ±0.001 ±0.005 ±0.001 ±0.005 ±0.001 ±0.005 ±0.001 ±0.005 ±0.003 ±0.007 ±0.003 ±0.007 / C %/ C Accuracy -10 to 60 C (without compensation) ±0.13 ±0.15 ±0.17 ±0.24 ±0.5 ±0.57 Accuracy -10 to 60 C (with compensation) ±0.04 ±0.05 ±0.06 ±0.09 ±0.22 ±0.25 Long Term Stability ±0.01 ±0.01 ±0.01 ±0.01 ±0.02 ±0.02 Resolution (@1Hz BW) Parameter Measuring range Zero Bias Error Accuracy (@20 C) Temperature Errors Zero Drift Sensitivity Drift Accuracy -10 to 60 C (without compensation) Accuracy -10 to 60 C (with compensation) Long Term Stability Resolution (@1Hz bandwidth) Notes Defines the calibrated measurement range. Direction of measurement can be reversed and zero position can be reset anywhere in range. Settings are stored in non volatile memory so are remembered after power down. This is the maximum angle from the device when it is placed on a perfectly level surface. The zero bias error can be removed from measurement errors either by mechanical adjustment, or as a fixed offset value after installation, or by using the setzcur command to zero the device (see page 8) This is the maximum error between the measured and displayed value at any point in the measurement range when the device is at room temperature (20 C). This value includes cross axis errors. These figures are for devices without additional temperature compensation. See part numbering options on page 7 for further details. If the device is mounted to a level surface in the zero position, this value is the maximum drift of the output angle per C change in temperature. When the temperature changes there is a change in sensitivity of the sensor s output. The error this causes in the measurement is calculated from the formula: E sd = SD x T x Where: E sd is the change in output (in degrees) due to sensitivity temperature change SD is the sensitivity drift specification from the above table (0.014%) T is the change is temperature in C is the current angle of the inclinometer axis in question in degrees. This is the maximum error between the measured and displayed value at any point in the measurement range at any temperature over the specified temperature range without individual temperature compensation. This is the maximum error between the measured and displayed value at any point in the measurement range at any temperature over the calibrated temperature range with individual temperature compensation. Stability depends on environment (temperature, shock, vibration and power supply). This figure is based on being powered continuously in an ideal environment. Resolution is the smallest measurable change in output. Page 2 of 14
3 Housing Drawing (single connector version) X 4.20 THRU ALL Axis Direction and Mounting Orientation Mounted on Horizontal Surface +ve -ve Page 3 of 14
4 Housing Drawing (dual connector version for ModBus) X 4.20 THRU ALL Page 4 of 14
5 Connector and Connection Details The connection socket is a 4 pin Binder 768 series M8 panel plug. It mates with straight cable socket part number or right angle cable socket There are also a range of pre-moulded leads available. Mating cables and connectors can be purchased from us separately. The connections are shown in the table below. Pin No. RS232 Pin Function RS485 Pin Function 1 +ve Supply +ve Supply 2 Ground Ground 3 RS232 Txd RS RS232 Rxd RS485 - Cable And Connector Accessories Right Angle Connector Part # EL-CON Right Angle Cable, 2m, PUR Part # EL-CAB Right Angle Cable, 5m, PUR Part # EL-CAB Straight Connector Part # EL-CON Straight Cable, 2m, PUR Part # EL-CAB Straight Cable, 5m, PUR Part # EL-CAB As well as these standard cables, custom cables can be supplied in any length up to 100m. All cables are shielded with a PUR black jacket. Certification The products are type approved to in accordance with the following directive(s): EMC Directive 2004/108/EC And it has been designed, manufactured and tested to the following specifications: BS EN :2006 BS EN55011:2007, Group 1 Class B Electrical equipment for measurement, control and laboratory use EMC Requirements Page 5 of 14
6 Frequency Filter Indexes The frequency response of the sensor can be changed to any of the response times shown in the table by sending the appropriate RS232 command (see page 6) or RS485 ModBus command (see page 8). The digital filter is a 2nd order Bessel low pass filter algorithm. The sensor has a built in mechanical damping at 18Hz and 2nd order analogue filter with a 8Hz cutoff frequency, so specifying a filter frequency above this value will not increase the response beyond this amount. Filter Index Freq. (Hz) Damping Time (ms) Part Numbering Series Prefix HPS - XX - X - XXX 05 - ±5 Full Scale Measurement Range 10 - ±10 Full Scale Measurement Range 15 - ±15 Full Scale Measurement Range 30 - ±30 Full Scale Measurement Range 45 - ±45 Full Scale Measurement Range 60 - ±60 Full Scale Measurement Range 1 - No additional temperature compensation 2 - Temperature compensation over -10 to 60 C RS232 Interface with LD standard communication protocol RS485 interface with LD standard communication protocol MOD - RS485 interface with ModBus protocol Example: HPS HPS Series Inclinometer ±15 Full Scale Measurement Range Temperature compensated over the range -10 to 60 C RS232 Output with LD standard communication protocol Page 6 of 14
7 Control Set Data is transmitted and received over RS232 in full duplex mode and for RS485 versions in half duplex mode. The default configuration is with the baud rate set to 38.4kbps, with 8 data bits, 1 stop bit and no parity. All commands are lower case and 7 bytes long. The time between each character of the command must be less than 100ms otherwise the device will discard the command. The settings are all stored in non volatile memory. Description Length get --x Returns the X axis angle as either: - An INT32 value equal to the angle x A fixed length ASCII string terminated with a carriage return depending on the setting of commands setoasc or setoint Shipping default is INT32. 4 bytes 9 bytes 0x XX XX XX XX <CR> gettemp Returns the temperature of the sensor as either: - An INT16 value equal to the temperature x A fixed length ASCII string terminated with a carriage return depending on the setting of commands setoasc or setoint Shipping default is INT32. 2 bytes 6 bytes 0x XX XX ±tt.t<cr> str9999 setcasc Set continuous output transmission rate in milliseconds ( ms) -str ms (0.1s) between transmissions -str ms (8.5s) between transmissions Sets the output to transmit the angle continuously in ASCII format at the rate defined bystrxxxx. 2 bytes OK 9 bytes ±xxx.xxx<cr> stpcasc Stops the continuous transmission of ASCII data (default mode) 2 bytes OK get-flt Returns the value of the current filter time constant in ms as an INT16 2 bytes 0x XX XX setdir1 setdir2 Sets the measurement direction to positive clockwise Sets the measurement direction to negative clockwise 2 bytes OK setzcur Tare function to set the current position to zero 2 bytes OK setzfac Cancels tare function and resets zero to factory setting 2 bytes OK setoasc Sets the output to ASCII format 2 bytes OK setoint Sets the output to Integer format 2 bytes OK setflt1 setflt2 setflt3 setflt4 setflt5 setflt6 setflt7 Sets the digital filter frequency response to 0.125Hz Sets the digital filter frequency response to 0.25Hz Sets the digital filter frequency response to 0.5Hz Sets the digital filter frequency response to 1Hz Sets the digital filter frequency response to 2Hz Sets the digital filter frequency response to 4Hz Sets the digital filter frequency response to 8Hz 2 bytes OK set-br1 set-br2 set-br3 set-br4 set-br5 set-br6 set-br7 Sets the BAUD rate to 2400bps Sets the BAUD rate to 4800bps Sets the BAUD rate to 9600bps Sets the BAUD rate to 19200bps Sets the BAUD rate to 38400bps Sets the BAUD rate to 57600bps Sets the BAUD rate to bps 2 bytes OK setter0 setter1 Disable 120Ω RS485 terminating resistor (default) Enable 120Ω RS485 terminating resistor 2 bytes OK Page 7 of 14
8 Software A free Windows based application for reading angle, logging and device configuration is available from our web site. It requires Windows XP SP3, Windows 7 or Windows 8, and works with 32 and 64 bit systems. It also requires the.net framework V3.5 or higher, and will prompt you to download and install this from Microsoft if it is not already installed on your system. A COM port is also required, and can either be a built in COM port, or a USB to Serial COM port. It is compatible with devices using the LD communication protocol as defined on page 6, it cannot be used with ModBus devices. Automatic or manual configuration of COM port parameters Compatible with single or dual axis sensors Adjustable number of decimal places on displays Logging of data at specified intervals into CSV file Setting device to absolute or relative measurement mode Switching the data transfer protocol between Integer and ASCII Changing the frequency response of the sensor Changing the Baud rate of the sensor We can also offer custom software development services, please contact us for further information. This software is provided 'as-is', without any express or implied warranty. In no event will the authors be held liable for any damages arising from the use of this software. Page 8 of 14
9 ModBus Control Set Data is transmitted and received over RS485 in half duplex mode using the ModBus RTU protocol. The following section provides some basic information about the serial communication between the host PC or PLC and the HPS. The full ModBus specification can be obtained from ModBus is a command/response protocol over a serial bus. The default ModBus serial parameters are: baud, 1 start bit, 8 data bits, no parity and 1 stop bit. The 8 data bits are sent LSB first. The baud rate can be changed to , 57600, 38400, 19200, 9600, 4800 or 2400 by sending the appropriate command. The byte order for all 16-bit values is Big Endian (most significant byte first). Read and write access to the HPS is done using ModBus Function Code 3 (read holding registers) and ModBus Function Code 6 (write single register) commands. These two function codes provide the basic functionality needed by most users of the HPS sensor. A user defined ModBus function code 110 is provided for less commonly used, off-line functions such as setting serial port parameters and changing the device address. ModBus device address must be in the range 1 to 247. All devices are shipped with a default address of 100 (decimal). Address 0 is the ModBus broadcast address. With this address all devices will perform the action of the function code. The maximum number of these devices that can be connected on a single network is 128. All ModBus commands and responses have a 16-bit CRC for error detection. ModBus RTU data is in binary format rather than ASCII, so it cannot be viewed properly on a text terminal. Below is a list of the register locations for reading and writing: ModBus Registers Parameter Address ModBus Register Address Description Read/Write X Axis Angle 0x00 40,001 0x01 40,002 Address 0x00 returns the lower 16 bits of the sensor X axis angle. This combines with address 0x01 to form a 32 bit signed integer value equal to the measured angle x Read Only Sensor Temperature 0x06 40,007 Returns a 16 bit signed integer value equal to the temperature of the sensor in degrees Celcius x 100 Read Only Sensor Filter Index 0x09 40,010 Returns a 16 bit integer value between 1 and 7 which relates to a table of filter responses from to 8Hz Read / Write Tare Function 0x14 40,021 When set to 1 the device is zeroed at the current position (relative mode). When set to 0 the device is returned to absolute measurement mode (tare cancelled) Read / Write RS485 Termination Resistor 0x15 40,022 When set to 0 the termination resistors are disabled (default mode). When set to 1 the termination resistors are enabled across the RS485 A and B data-lines. Read / Write Page 9 of 14
10 Frequency Filter Indexes The frequency response of the sensor can be changed to any of the response times shown in the table. The digital filter is a 2nd order Besel low pass filter implemented in a FIR algorithm. The sensor has a built in mechanical filter at 18Hz and an electronic filter with a 8Hz cutoff frequency, so specifying a filter frequency above this value will not increase the response beyond this amount. Filter Index Freq. (Hz) Damping Time (ms) Reading a Holding Register The data from the device is stored in holding registers as detailed on page 4. Function code 0x03 is used to read these registers. Below is the command and response message format, including the error response in the even there is an error. Byte Data No Of Bytes Description 0x03 1 Function code for read register 0x Starting register (0x0000 is X axis angle) 0x Number of registers to read 0xCDFE 2 CRC-16 of all bytes 0x03 1 Function code for read register 0x04 1 Byte count (2 x number of regsiters) 0x First and second register data : 0xA69C 2 0x0000A69C = (decimal) 0xB4FC 2 CRC-16 of all bytes Error 0x83 1 ModBus error function code 0x01 1 Exception Code (0x01 invalid function code, 0x02 invalid register address) 0x90EF 2 CRC-16 of all bytes Page 10 of 14
11 Writing to a Holding Register Data can be written to some registers, such as the registers that store the filter indexes for each axis frequency response. Function code 0x06 is used to write these registers as detailed below. Byte Data No Of Bytes Description (same as command) Error 0x06 1 Function code for write register 0x Register to write (0x0009 is axis filter) 0x Data to write (16 bit). 0x0003 = 0.5Hz 0x103C 2 CRC-16 of all bytes 0x06 1 Function code for write register 0x Register to write (0x0009 is axis filter) 0x Data to write (16 bit). 0x0003 = 0.5Hz 0x103C 2 CRC-16 of all bytes 0x83 1 ModBus error function code 0x01 1 Exception Code (0x01 invalid function code, 0x02 invalid register address) 0x90EF 2 CRC-16 of all bytes Changing the BAUD Rate The BAUD rate of the device can be changed using the special function code 0x6E and special command code 0x8F. The reply is sent at the original BAUD rate, the device BAUD rate is only updated to the new setting after a 250ms delay: Byte Data No Of Bytes Description 0x6E 1 Function code - 0x6E 0x8F 1 LD command - 0x8F = set baud 0x = = = = = = = x5AF8 2 CRC-16 of all bytes 0x6E 1 Function code - 0x6e 0x8F 1 LD command - 0x8F = set baud 0x = success, 1 = failed 0x1AF9 2 CRC-16 of all bytes Page 11 of 14
12 Changing the Device Address The Address of the device can be changed using the special function code 0x6E and special command code 0x91. The details are shown in the table below: Byte Data No Of Bytes Description 0x6E 1 Function code - 0x6e 0x91 1 LD command - 0x91 = change address 0x01 1 New Address = 1 0xD299 2 CRC-16 of all bytes 0x6E 1 Function code - 0x6e 0x91 1 LD command - 0x91 = change address 0x = success 1 = failed 0x CRC-16 of all bytes Examples of ModBus Example 1: Read the angle from the sensor X axis with address 100 (0x64) function code starting reg. to read (0x0000) number of reg. to read (0x0002) cd fe (positive angle) function code byte count angle (0x0000a69c = decimal ( degrees) a6 9c b4 fc (negative angle) function code byte count angle (0xfffda7d7 = decimal ( degrees) ff fd a7 d7 54 bf Page 12 of 14
13 Example 2: Change the device address from 100 to 1: special function code LD command for change address new address (0x01) 64 6e d2 99 special function code LD command for change address Success/Fail (0x00 = success) 64 6e Example 3: Change the frequency response to 1Hz: function code register to write to (0x0009) data to write (0x0003 = 0.5Hz) c function code register written to (0x0009) data written (0x0003 = 0.5Hz) c Page 13 of 14
14 Example 4: Setting the tare function (current position to zero): function code register to write to (0x0014) data to write (0x0001 = set tare on) fb function code register written to (0x0014) data written (0x0001 = set tare on) fb Page 14 of 14
SOLAR-360 : 360 Inclinometer, RS232 or RS485 Output
Features Single axis measurement, range ±180 High resolution and accuracy Low temperature drift, with optional temperature compensation to further improve temperature performance. RS232 or multi-drop RS485
More informationSOLAR-2 : Dual Axis Inclinometer, RS232 or RS485 Output
Features Dual axis measurement, range from ±5 to ±45 High resolution and accuracy Low temperature drift, with optional temperature compensation to further improve temperature performance. RS232 or multi-drop
More informationFeatures. Description. General Specifications. VS Series Inclinometer : Dual Axis, RS232 and Analogue Output
Features Dual axis measurement from ±5 to ±60 High resolution and accuracy Low temperature drift, with optional temperature compensation to further improve temperature performance. RS232 output interface
More informationBW-IMU200 Serials. Low-cost Inertial Measurement Unit. Technical Manual
Serials Low-cost Inertial Measurement Unit Technical Manual Introduction As a low-cost inertial measurement sensor, the BW-IMU200 measures the attitude parameters of the motion carrier (roll angle, pitch
More information2F. No.25, Industry E. 9 th Rd., Science-Based Industrial Park, Hsinchu, Taiwan Application Note of OGM220, AN001 V1.8
Application Note of OGM220, AN001 V1.8 1.0 Introduction OGM220 series is a dual channels NDIR module having a digital output directly proportional to CO2 concentration. OGM220 is designed for multi-dropped
More informationUser manual. Inclinometer with Analog-RS232-Interface IK360
User manual Inclinometer with Analog-RS232-Interface IK360 Table of content 1 GENERAL SAFETY ADVICE... 3 2 INTRODUCTION... 4 2.1 IK360... 4 2.2 ANALOG INTERFACE... 4 2.3 IK360 ANALOG... 4 3 INSTALLATION...
More informationisma-b-w0202 Modbus User Manual GC5 Sp. z o.o. Poland, Warsaw
isma-b-w0202 isma-b-w0202 Modbus User Manual GC5 Sp. z o.o. Poland, Warsaw www.gc5.com 1. Introduction... 4 2. Safety rules... 4 3. Technical specifications... 5 4. Dimension... 6 5. LED Indication...
More informationHURRICANE Radio Modem. FULL DUPLEX Radio MODEM
FULL DUPLEX Radio MODEM Direct Cable Replacement Range 2KM RS232 / RS485 / USB Host Data Rates up to 38,400 Baud RF Data Rates to 115200Kbps Waterproof IP68 Enclosure 8 User Selectable Channels CE Compliant
More informationCMPS09 - Tilt Compensated Compass Module
Introduction The CMPS09 module is a tilt compensated compass. Employing a 3-axis magnetometer and a 3-axis accelerometer and a powerful 16-bit processor, the CMPS09 has been designed to remove the errors
More informationT5340, T5341, T5440, T5441 T6340, T6341, T6440, T6441
Programmable transmitter of CO2 concentration T5340, T5341, T5440, T5441 Programmable transmitter of temperature, relative humidity, CO2 and other derived humidity values T6340, T6341, T6440, T6441 with
More informationExtremely robust Inclination Sensor with Analog Output U8 I1. Measurement range ±180 for 1 axis or ±60 for 2 axes
PTAM5 Extremely robust Inclination Sensor with Analog Output Analog Inclination Sensor with 1 or 2 axes in MEMS technology Measurement range ±180 for 1 axis or ±60 for 2 axes class IP67 / IP69K, optional
More informationINCLINOMETER RS232 SWITCH
Main Features - Two axis digital inclinometer - Angle measurement range of +/-5, +/-15 and +/-30, Resolution up to 0.001 - Interface: RS232, Code: ASCII, Switch Open Collector - Housing: 70 mm Programmable
More informationModbus communication module for TCX2: AEX-MOD
Modbus communication module for TCX2: Communication Specification TCX2 is factory installed in TCX2 series controllers with -MOD suffix, and is also available separately upon request for customer installation
More information13. OP-03 RS-232C SERIAL INTERFACE
This document hosted by: www.oldwillknottscales.com 13. OP-03 RS-232C SERIAL INTERFACE This interface allows the HC-i series to be connected with a multifunction printer or a personal computer. The OP-03
More informationArduino Arduino RF Shield. Zulu 2km Radio Link.
Arduino Arduino RF Shield RF Zulu 2km Radio Link Features RF serial Data upto 2KM Range Serial Data Interface with Handshake Host Data Rates up to 38,400 Baud RF Data Rates to 56Kbps 5 User Selectable
More informationCMPS11 - Tilt Compensated Compass Module
CMPS11 - Tilt Compensated Compass Module Introduction The CMPS11 is our 3rd generation tilt compensated compass. Employing a 3-axis magnetometer, a 3-axis gyro and a 3-axis accelerometer. A Kalman filter
More informationBW-VG525 Serials. High Precision CAN bus Dynamic Inclination Sensor. Technical Manual
Serials High Precision CAN bus Dynamic Inclination Sensor Technical Manual Introduction The Dynamic Inclination Sensor is a high precision inertial measurement device that measures the attitude parameters
More informationHarris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR
Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model 6012-06XR Specifications & Dimensions 2 Theory of Operation 3 System Block Diagram 4 Operator Controls & Connectors 5 Test Connections
More informationCharacteristics and functioning
Characteristics and functioning /25 ENOD4 PRODUCT RANGE:... 4. General presentation:... 4.2 enodview software tool... 4.3 Versions and options:... 4.3. Versions:...4.3.2 Options :...4.4 Dimensions:...
More informationX3M. Multi-Axis Absolute MEMS Inclinometer Page 1 of 13. Description. Software. Mechanical Drawing. Features
Page 1 of 13 Description The X3M is no longer available for purchase. The X3M is an absolute inclinometer utilizing MEMS (micro electro-mechanical systems) technology to sense tilt angles over a full 360
More informationCarbon Dioxide (Tiny CO2) Gas Sensor. Rev TG400 User Manual
Carbon Dioxide (Tiny CO2) Gas Sensor Rev. 1.2 TG400 User Manual The TG400 measuring carbon dioxide (chemical formula CO2) is a NDIR (Non-Dispersive Infrared) gas sensor. As it is contactless, it has high
More informationDevice manual Inclination sensor 2 axes JN /00 04/2015
Device manual Inclination sensor 2 axes JN2300 80228165/00 04/2015 Contents 1 Preliminary note................................................. 4 1.1 Symbols used...............................................
More informationPyroMiniUSB Series Operators Guide
PyroMiniUSB Series Operators Guide The PyroMiniUSB is a simple, compact infrared temperature sensor with USB communications. It measures the surface temperature of a variety of materials without contact.
More informationMV110-8AS. Analog input module 8 channel. User guide
MV110-8AS Analog input module 8 channel User guide MV110-8AS_2016.12_0226_EN All rights reserved Subject to technical changes and misprints Contents 1 Description... 2 1.1 Function... 2 1.2 RS485 network...
More informationX20(c)AI General information. 2 Coated modules. 3 Order data. X20(c)AI4622
X20(c)AI4622 1 General information The module is equipped with 4 inputs with 13-bit (including sign) digital converter resolution. It is possible to select between the current and voltage signal using
More informationP/N: AX06080X. TECHNICAL DATASHEET #TDAX06080X Triaxial Inclinometer SAE J1939 or CANopen 2 M12 Connector(s), IP67 with Electronic Assistant
TECHNICAL DATASHEET #TDAX06080X Triaxial Inclinometer SAE J1939 or CANopen 2 M12 Connector(s), IP67 with Electronic Assistant P/N: AX06080X Features: Reliable, real-time, accurate and stable slope angle
More informationKnow your energy. Modbus Register Map EB etactica Power Bar
Know your energy Modbus Register Map EB etactica Power Bar Revision history Version Action Author Date 1.0 Initial document KP 25.08.2013 1.1 Document review, description and register update GP 26.08.2013
More informationDatalogger DL.OCS/N/RS485
Datalogger DL.OCS/N/RS485 Customer benefits Multi-parameter probe: pressure, temperature and conductivity High-precision digital data logger with user-friendly software Thanks to the huge memory (1.5 Mio.
More informationCommunications message formats
Communications message formats The SP-1 or SP-2 unit communicates via the airtalk compatible communications port. This port consists of a shared, single wire asynchronous link. The link operates with one
More informationDatalogger DL.OCS/N/RS485
Datalogger DL.OCS/N/RS485 Version: 18.02.2014 Technical Specifications Pressure measuring range (mh2o) 2... 5 > 5... 20 > 20... 250 Overpressure 3 bar 3 x FS ( 3 bar) 3 x FS Burst pressure, (1) > 200 bar
More informationAbsolute Encoders Multiturn
The Sendix F36 multiturn with the patented Intelligent Scan Technology is an optical multiturn encoder in miniature format, without gears and with 00% insensitivity to magnetic fields. With a size of just
More informationI-7088, I-7088D, M-7088 and M-7088D User Manual
I-7088, I-7088D, M-7088 and M-7088D User Manual I-7000 New Features 1. Internal Self Tuner 2. Multiple Baud Rates 3. Multiple Data Formats 4. Internal Dual WatchDog 5. True Distributed Control 6. High
More informationUniversal MEMS Inclination Sensor with Analog Output. Output /Excitation U6 U8 I1
PTAM27 Universal MEMS Inclination Sensor with Analog Output Analog Inclination Sensor with 1 axis or 2 axes in MEMS technology Measurement range ±180 with 1 axis or 2 axes class IP67 Linear analog ouput
More informationPROCESS & TEMPERATURE CONTROLLERS
PROCESS & TEMPERATURE CONTROLLERS NOVA PD54 Series Thermocouple, RTD, & Process Inputs High Accuracy Auto-Tuning PID Heating & Cooling Models Universal Power Supply 1-24 VAC Up to 3 Relays & 2 Analog Outputs
More informationSerial Communications RS232, RS485, RS422
Technical Brief AN236 Technical Brief AN236Rev A Serial Communications RS232, RS485, RS422 By John Sonnenberg S u m m a r y Electronic communications is all about interlinking circuits (processors or other
More informationUser s instructions. Page 1 sur 20 AXD-C / AAD-C / DVX-C / DVS-C : User s instructions B
User s instructions Page 1 sur 20 : User s instructions 195752-B Document revisions version date description A 13/01 - Creation B 04/17 - Add DVX-C and DVS-C Page 2 sur 20 : User s instructions 195752-B
More informationC Mono Camera Module with UART Interface. User Manual
C328-7221 Mono Camera Module with UART Interface User Manual Release Note: 1. 16 Mar, 2009 official released v1.0 C328-7221 Mono Camera Module 1 V1.0 General Description The C328-7221 is VGA camera module
More informationInfraStruXure Manager v4.x Addendum: Building Management System Integration
InfraStruXure Manager v4.x Addendum: Building Management System Integration Introduction This addendum explains the integration of the APC InfraStruXure Manager Appliance with a Building Management System
More informationInstruction Manual Single and Dual Axis Inclinometer P-Series
Instruction Manual Single and Dual Axis Inclinometer P-Series Version 1.2 Hauert 13, D-44227 Dortmund, Germany 1 of 16 fax: +49-(0)231-9740-200 Table of Contents 1 Introduction... 3 2 Notice... 3 3 History...
More informationCooLink Programmers Reference Manual (PRM)
CooLink Programmers Reference Manual (PRM) CooLink RS232/RS485 Interface Adapter for Residential Air Conditioners CooLink D CooLink S CooLink T Document Revision 0.8 7/15/2012 CooLink PRM Contents 2 Table
More informationWIRELESS MODBUS GATEWAY WGW410
WIRELESS MODBUS GATEWAY WGW410 The Tekon Wireless Modbus Gateway WGW410 is specifically designed to meet the most rigorous requirements of operation in the industrial process environments. Due to their
More informationAbsolute Encoders Singleturn
The absolute singleturn encoders Sendix 5853 SIL and 5873 SIL are perfectly suited for use in safety-related applications up to SIL3 according to DIN EN ISO 6800-5- or PLe to DIN EN ISO 3849. The extra
More informationHG G B. Gyroscope. Gyro for AGV. Device Description HG G B. Innovation through Guidance. Autonomous Vehicles
Device Description HG G-84300-B Autonomous Vehicles Gyroscope HG G-84300-B Gyro for AGV English, Revision 06 Date: 24.05.2017 Dev. by: MG/WM/Bo Author(s): RAD Innovation through Guidance www.goetting-agv.com
More informationHome Automation, Inc. Omnistat2. RC-1000 and RC-2000 Communicating Thermostat. Serial Protocol Description
Home Automation, Inc. Omnistat2 RC-1000 and RC-2000 Communicating Thermostat Serial Protocol Description This document contains the intellectual property of Home Automation, Inc. (HAI). HAI authorizes
More informationKAPPA M. Radio Modem Module. Features. Applications
KAPPA M Radio Modem Module Features Intelligent RF modem module Serial data interface with handshake Host data rates up to 57,600 baud RF Data Rates to 115Kbps Range up to 500m Minimal external components
More informationST600 TRANSMITTER OPERATING INSTRUCTIONS
ST600 TRANSMITTER OPERATING INSTRUCTIONS 1892 1273 These operating instructions are intended to provide the user with sufficient information to install and operate the unit correctly. The Wood and Douglas
More informationMADEinUSA OPERATOR S MANUAL. RS232 Interface Rev. A
MADEinUSA OPERATOR S MANUAL RS232 Interface 92-3006 Rev. A www.iradion.com Iradion Laser, Inc. 51 Industrial Dr. N. Smithfield, RI 02896 (410) 762-5100 Table of Contents 1. Overview... 2 2. Equipment Required...
More informationBusWorks 900EN Series Modbus TCP/IP 10/100M Industrial Ethernet I/O Modules
BusWorks 900EN Series Modbus TCP/IP 10/100M Industrial Ethernet I/O Modules Six Differential Current Inputs Six Differential Voltage Inputs USER S MANUAL ACROMAG INCORPORATED Tel: (248) 295-0880 30765
More informationOperation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.
Electronics & Software Type 5080A... Multichannel Laboratory This universal laboratory charge amplifier can be used for force and torque measurements with piezoelectric dynamometers or force plates. Piezoelectric
More informationAn internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.
TECHNICAL DATASHEET #TDAX06070X Triaxial Inclinometer with Gyro ±180⁰ Pitch/Roll Angle Pitch Angle Rate Acceleration SAE J1939, Analog Output or RS-232 Options 2 M12 Connectors, IP67 with Electronic Assistant
More informationIP1 Datasheet PWM OUTPUT WITH SINGLE CHANNEL ADC MODULE FEATURES DESCRIPTION CONNECTOR DETAILS
PWM OUTPUT WITH SINGLE CHANNEL ADC MODULE FEATURES 1 PWM Output (3.3V) 0 Hz 1 khz Single Channel 3.3V 12-bit ADC input for voltage sensing Optional automated PWM adjustment based on input voltage for standalone
More informationAbsolute Encoders Multiturn
Absolute Encoders Multiturn Functional Safety, optical The absolute multiturn encoders Sendix 5863 SIL and 5883 SIL are perfectly suited for use in safety-related applications up to SIL3 according to DIN
More informationTAS APFC Controller / Load Managers with MOD-BUS Interface
TAS APFC Controller / Load Managers with MOD-BUS Interface Designed & Prepared by TAS PowerTek Pvt. Ltd., W-61, MIDC Ambad, Nasik-422010, India. Updated on: 4th June 2017, Sunday. Data Parameter Field
More informationIntegrity Instruments
Integrity Instruments P.O. Box 451 Order Phone 800-450-2001 Pine River Minnesota Fax Phone 218-587-3414 56474 USA Tech Phone 218-587-3120 http://www.integrityusa.com 485M300 Series I/O Modules Digital
More informationData Sheet THE SCA121T DUAL AXIS INCLINOMETER MODULES. Features. Applications
Data Sheet THE SCA121T DUAL AXIS INCLINOMETER MODULES The SCA121T Series contain 3D-MEMS-based dual axis inclinometer modules that provide instrumentation grade performance for leveling applications in
More informationPicture 1 PC & USB Connection
USB Ethernet HART Profi-bus DeviceNet EtherCAT CANopen CAN RS Zigbee Analog Switch Vibration-wire PWM SSI CDMA GPRS Wi-Fi USB Inclinometer Features - Reference with USB2.0 protocol - P2P and compatible
More informationPOSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire
POSICHRON Position Sensor Stick Design with Analog Specifications POSICHRON position sensor in stick design Protection class IP67 Measurement range 0... 100 up to 0... 5750 mm Absolute position measurement
More informationGPRS Inclinometer. Zigbee. CDMA Vibration-wire. SSI PWM Switch Analog. Features. Descriptions
GPRS Inclinometer Features - Industry GPRS interface - Quad-Band 850/ 900/ 1800/ 1900 MHz Transmission - worldwide - Support PBCCH, CSD up to 14.4 kbps - Support single/multi-center modes - Support domain
More informationMGA103 Single Axis MEMS Gyro with Triaxial Accelerometer
Cost Effective Z Axis MEMS Gyro with 3 Accelerometers Heading: diverging 0.1 /hour Range: acc ±2g, gyro ±300 /s, (ODM supported) Wide Input Power Range: 6~14VDC Compact and Lightweight - 50 x 45 x 21 (mm),
More informationDTM.OCS.S/N - Modbus Level Transmitter
Digital Submersible Level Transmitter with Modbus Interface DTM.OCS.S/N - Modbus Level Transmitter CUSTOMER BENEFITS High precision digital level transmitter with standard Modbus interface Fast customization
More informationApplications. Operating Modes. Description. Part Number Description Package. Many to one. One to one Broadcast One to many
RXQ2 - XXX GFSK MULTICHANNEL RADIO TRANSCEIVER Intelligent modem Transceiver Data Rates to 100 kbps Selectable Narrowband Channels Crystal controlled design Supply Voltage 3.3V Serial Data Interface with
More informationLine-to-line RMS Volts, 3 phases 4 digits (XXX.X) Volts
digital ac POWER MONITOR DESCRIPTION The DSP is a three-phase, three-element multifunction digital transducer with outputs for voltage, current, and power via serial communication. Applications include
More informationICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...
Electronics & Software ICAM Type 5073A... Industrial Charge Amplifier for Applications in Manufacturing The ICAM charge amplifier (Industrial Charge Amplifier Manufacturing) converts the piezoelectric
More informationVoltage regulator TAPCON 240
Voltage regulator TAPCON 240 Supplement 2398402/00 Protocol description for IEC 60870-5-103 All rights reserved by Maschinenfabrik Reinhausen Copying and distribution of this document and utilization and
More informationCharacteristics and functioning
Characteristics and functioning 1/36 enod4-d Characteristics and functioning NU-eNod4D-ETH-E-1014_216710-A 1 ENOD4 PRODUCT RANGE... 5 1.1 General presentation... 5 1.2 Versions and options... 5 1.2.1 Versions...
More informationSPECIFICATIONS. ACA2000 -High Accuracy Digital Type Dual-Axis Inclinometer with Full Temperature Compensation. Item No.:ACA2000
SPECIFICATIONS Item No.:ACA2000 Description: High Accuracy Digital Type Dual-Axis Inclinometer Version:Ver.08 Production implementation standard reference Enterprise quality system standards: ISO9001:
More informationModel: ADC-x/DIG-x. RS-232 / RS-485 Data Acquisition Digital I/O v2.2 Firmware. SuperLogics. Integrity Instruments. SuperLogics
Model: ADC-x/DIG-x RS-232 / RS-485 Data Acquisition Digital I/O v2.2 Firmware SuperLogics SuperLogics 94 Falmouth Road Newton, MA 02465 USA Phone: (617) 332-3627 Fax: (617) 332-4687 Web: www.superlogics.com
More informationABSOLUTE ROTARY ENCODER SSI PROGRAMMABLE
Main Features - Compact and heavy-duty industrial model - Interface: Synchronous-serial (RS422/485) - Housing: 58 mm - Shaft: 6 or 10 mm - Resolution: Max. 25 Bit =,554,42 steps over 4,096 revolutions
More informationThe "FISH" Quad Hand Sensor
The "FISH" Quad Hand Sensor Physics and Media Group MIT Media Laboratory 20 Ames Street E15-022 Cambridge, Mass 02139-4307 (617) 253-2383 phm@media.mit.edu ** U S E R S G U I D E ********* TABLE OF CONTENTS
More informationPOSICHRON position sensor in a stainless steel pressure case. Voltage: V, 3 wire Current: ma, 3 wire
Rod Profile with Analog Specifications POSICHRON position sensor in a stainless steel pressure case Protection class IP68 Compression-proof up to 15 bar Measurement range 0... 100 to 0... 5750 mm Absolute
More informationKnow your energy. Modbus Register Map EM etactica Power Meter
Know your energy Modbus Register Map EM etactica Power Meter Revision history Version Action Author Date 1.0 Initial document KP 25.08.2013 1.1 Document review, description and register update GP 26.08.2013
More informationSMARTALPHA RF TRANSCEIVER
SMARTALPHA RF TRANSCEIVER Intelligent RF Modem Module RF Data Rates to 19200bps Up to 300 metres Range Programmable to 433, 868, or 915MHz Selectable Narrowband RF Channels Crystal Controlled RF Design
More informationA6500-UM Universal Measurement Card
Specifications Sheet A6500-UM Universal Measurement Card The A6500-UM Universal Measurement Card is a component of the CSI 6500 ATG machinery protection system. The card is equipped with 2 sensor input
More informationMETEOROLOGICAL INSTRUMENTS
METEOROLOGICAL INSTRUMENTS INSTRUCTIONS ULTRASONIC ANEMOMETER MODEL 86106 R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com
More informationMETERSUK. SmartLink D Y N A M i T E. EM415 MOD Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION. Single Phase Metering
METERSUK LTD s a l e s @ m e t e r s. c o. u k 0 1 5 2 4 5 5 5 9 2 9 Series Smart Energy Meter KEY FEATURES Single Phase Metering Single phase metering 4 din modules, Standard DIN rail Format (DIN43880)
More informationCost efficient design Operates in full sunlight Low power consumption Wide field of view Small footprint Simple serial connectivity Long Range
Cost efficient design Operates in full sunlight Low power consumption Wide field of view Small footprint Simple serial connectivity Long Range sweep v1.0 CAUTION This device contains a component which
More informationMV110-8A. Analog input module 8 channel. User guide
MV110-8A Analog input module 8 channel User guide MV110-8A_2016.12_0225_EN All rights reserved Subject to technical changes and misprints Contents 1 Description... 2 1.1 Function... 2 1.2 RS485 network...
More informationPicture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW
Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Four wire system Piezoresistive measuring element Pressure measurement relative or absolute Output signal 4-20 ma and RS-485
More informationMG100 Single Axis MEMS Gyro
Cost Effective Z Axis MEMS Gyro Heading: diverging 0.1 /hour Range: gyro ±300 /s, (ODM supported) Wide Input Power Range: 6~14VDC Compact and Lightweight - 50 x 45 x 21 (mm), 70g Wide Working Temperature:
More informationVoltage regulator TAPCON 260
Voltage regulator TAPCON 260 Supplement 2531975/00 Protocol description for IEC 60870-5-103 All rights reserved by Maschinenfabrik Reinhausen Copying and distribution of this document and utilization and
More information9320 Manual Portable Battery Powered Indicator
9320 Manual Portable Battery Powered Indicator Interface, Inc. 7401 E. Butherus Dr. Scottsdale, AZ 85260 800-947-5598 480-948-1924 (fax) www.interfaceforce.com CONTENTS INTRODUCTION...2 USER OPERATION...2
More informationDigital Fluid Damped Single Point Load Cell
Model 240D Digital Fluid Damped Single Point Load Cell FEATURES Fully calibrated and filtered digital output High update rate, up to 1200 updates per second Checkweigher function - reading acquired over
More informationUSER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter
USER MANUAL MODEL 2029 Parallel to Serial/ Serial to Parallel Interface Converter C E R T I F I E D An ISO-9001 Certified Company Part #07M2029-B, Rev. C Doc. #102011UB Revised 6/16/09 SALES OFFICE (301)
More informationSilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors.
SilverMax Datasheet NEMA 23 Servomotors QuickSilver Controls, Inc. www.quicksilvercontrols.com SilverMax Datasheet - NEMA 23 Servomotors 23 Frame Sizes: 23-3, 23-5, 23H-1, 23H-3, 23H-5 / Series: E, E3,
More informationRF1276 Long Distance Transceiver module V2.0
1. General RF1276 series is a low cost, ultra-low power, high performance transparent two way semi-duplex LoRa modulation transceiver with operation at 169/433/868/915 Mhz. It integrates with high speed
More informationDVC700 Series Programmable System Controller
Programmed with HCT s Intella Software Suite 23 I/O (14 inputs & 9 outputs), 2 CAN interfaces Supply voltage 9-30Vdc The is a robust programmable controller for solenoid-operated proportional valves. It
More informationTechnical Note #15. Radio Frequency Modems. GE ED&C Home Search ED&C GE ED&C Power Management Home GE ED&C PMCS Home
1 of 5 GE ED&C Home Search ED&C GE ED&C Power Management Home GE ED&C PMCS Home GE Power Management Control System Description Software Hardware Operation Product Support Operator Interfaces F A Q s App
More informationInterfacing To Climatronics Tacmet II Sonic Weather Station
H NS AN_CLI Interfacing To Climatronics Tacmet II Sonic Weather Station 1/10/01 1.0 General The CPP-3794 provides an interface with the Climatronics Tacmet II Sonic Weather Station. The basic unit provides
More informationDevice manual Inclination sensor 2 axes. JN2300 from firmware /00 05/2016
Device manual Inclination sensor axes JN300 from firmware.3.0 805450/00 05/06 Contents Preliminary note................................................. 4. Symbols used...............................................
More informationData Acquisition Modules/ Distributed IO Modules
User Manual Data Acquisition Modules/ Distributed IO Modules Future Design Controls, Inc. 7524 West 98 th Place / P.O. Box 1196 Bridgeview, IL 60455 888.751.5444 - Office: 888.307.8014 - Fax 866.342.5332
More informationTP4-WT4 Serial Communications Output Addendum
TP4-WT4 Serial Communications Output Addendum AMALGAMATED INSTRUMENT CO PTY LTD ACN: 001 589 439 Unit 5, 28 Leighton Place Hornsby Telephone: +61 2 9476 2244 e-mail: sales@aicpl.com.au NSW 2077 Australia
More informationCost efficient design Operates in full sunlight Low power consumption Wide field of view Small footprint Simple serial connectivity Long Range
Cost efficient design Operates in full sunlight Low power consumption Wide field of view Small footprint Simple serial connectivity Long Range sweep v1.0 CAUTION This device contains a component which
More informationRF7129 Ultra-low power Tranceiver module V2.0
1. General RF7129 series is a low cost, ultra-low power, high performance transparent two way semi-duplex GFSK transceiver with operation at 433/470/868/915 Mhz. It integrates with high speed MCU from
More informationINTRODUCTION. T hank you for your HB8215/HB8216 loadcell indicator purchase. The HB8215 and HB8216 are the best choice for industrial weighing
INTRODUCTION T hank you for your HB8215/HB8216 loadcell indicator purchase. The HB8215 and HB8216 are the best choice for industrial weighing application requiring quality, performance and economy. Please
More informationPressure transmitter for mobile hydraulic applications With output signals CANopen and J1939
Electronic pressure measurement Pressure transmitter for mobile hydraulic applications With output signals CNopen and J1939 Model MHC-1 WIK data sheet PE 81.49 pplications Construction machinery gricultural
More informationMS2711B Hand-Held Spectrum Analyzer
MS2711B Hand-Held Spectrum Analyzer Programming Manual Hand-Held Spectrum Analyzer, for Measuring, Monitoring and Analyzing Signal Environments WARRANTY The Anritsu product(s) listed on the title page
More informationModel D875 Mini Tuff Tilt Digital Tiltmeter
The model 875 Mini Tuff Tilt Tiltmeter combines high precision and durability in a miniaturized and economical instrument package. Using MEMS technology, the 875 delivers superior measurement accuracy
More informationPOSIWIRE. WS85 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet
Cable Extension Position Sensors with internal magnetic encoder Position Sensor Datasheet Copyright ASM GmbH Am Bleichbach 18-24 85452 Moosinning Germany The information presented in this data sheet does
More informationAT-XTR-7020A-4. Multi-Channel Micro Embedded Transceiver Module. Features. Typical Applications
AT-XTR-7020A-4 Multi-Channel Micro Embedded Transceiver Module The AT-XTR-7020A-4 radio data transceiver represents a simple and economical solution to wireless data communications. The employment of an
More informationAbsolute Encoders - Singleturn
The Sendix 5853 and Sendix 5873 singleturn encoders with SSI or BiSS interface and optical sensor technology can achieve a resolution of max. 7 bits. These encoders are also available with an optional
More information