J IPC IGBT power converter
|
|
- Harold Boone
- 5 years ago
- Views:
Transcription
1 M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, Fulda, Germany Postal address: Fulda, Germany Phone: Fax: Internet: JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2TT, UK Phone: Fax: JUMO PROCESS CONTROL INC. 885 Fox Chase, Suite 103 Coatesville PA 19320, USA Phone: JUMO Fax: Internet: Data Sheet Page 1/6 J IPC IGBT power converter with amplitude control Brief description The J IPC is a power converter for controlling heater loads that previously required a transformer (either a variable transformer or a combination of transformer and thyristor power unit). It functions in such a way that it can effectively be thought of as an electronic transformer with a pulsed DC output voltage. It combines the advantages of conventional variable transformers, such as amplitude control and sinusoidal supply loading, with the advantages of thyristor power switches, such as current limiting, load monitoring, underlying control loops and so on. There is no electrical isolation between the supply voltage and the load voltage. The converter is suitable for all those applications where substantial resistive loads have to be switched. Thanks to the amplitude control (i.e. the current drawn from the supply is always sinusoidal), synchronous clock controls (as for burst-firing operation) or powerfactor compensation networks (to compensate for phase-control reactive power) are not required. Overview of function Front-panel settings LED display Type Load fault threshold (load fail adjust) Full-wave output (max. Power adjust) Current limiting (current limit) Power output adjustment 2 2 (output adjust V,P,I ) Base load setting (min. Power adjust) Inputs Control inputs for: - current - voltage - potentiometer 5 k Firing pulse inhibit floating contact Supply for control and power section u i supply voltage supply current IGBT power converter Overtemperature (overheating) Current limiting (current limit) Load/partial load failure (load fail) Standby (power) Outputs Power level output V (V,P, I ) Resistance output 0 5 V ( R ) Load fault output via relay or optocoupler Load current i Features k low interference (flicker) on the supply when operating substantial resistive loads k can operate low-voltage heater elements directly from the supply, without a step-down transformer k minimum harmonic generation in the supply to the equipment and light weight (no power transformer needed) k short-circuit proof during power-on k supply current drawn is proportional to the power required (amplitude control) k control is independent of the resistance characteristic of the heater elements k compensation of the ageing process in SIC heater elements k minimum control reactive power k compact size k free selection of the underlying control loop V 2, P, I 2
2 Page 2/6 Technical data Supply Supply for power section 115V AC +15%/ -20%, 48 63Hz 230V AC +15%/ -20%, 48 63Hz 400V AC +15%/ -20%, 48 63Hz 115V AC +15%/ -20%, 48 63Hz, 50 VA (only if also 115V AC for power section) 230V AC +15%/ -20%, 48 63Hz, 50 VA Supply for control section Load voltage V L eff 20V, 60V, 90V, 120V, 150V DC (other voltages on request) Load current I L eff 70A DC Load type resistive loads Phase effect The limits as per EN can be met through additional interference suppression measures. Control Control signal 0(4) 20mA R i = 50Ω 0(2) 10V R i = 25kΩ 0(1) 5V R i = 12kΩ manual control through external 5 kω potentiometer Input signal attenuation setting range % Fault signal output Relay (changeover contact), no contact protection circuit Optocoupler output 150,000 operations at a contact rating of 3A 230V 50Hz resistive load I Cmax = 2mA, V CEOmax = 32V General data Circuit type Single-phase operation Operating mode Amplitude control Underlying control Standard is free choice between V 2, P, I 2 control via internal switches Current limiting During operation, the load current can be adjusted from the front within the range % I N using a trimmer. The r.m.s. value of the load current is limited. Base load setting 0 100% Partial load break % of the nominal current Power level output Standard is free choice between V 2, P, or I 2 signal via internal switches, adjustable 0 5V to 0 10V, I max 2mA, offset deviation ± 5% Power loss 5 x I L (A) Control accuracy Supply voltage fluctuations within the tolerance band (+15%/ -20%) are compensated with an accuracy of ± 0.5% Electrical connection Control cables via screw terminals for conductor cross-sections mm 2. Load connections via cable lugs to DIN Enclosure protection IP00 to EN , heat sink is earthed Protection class Protection class I, with separation of the control circuits, for connecting to SELV circuits Permissible ambient 5 to 40 C (3K3 to EN ) temperature range Permissible -10 to +70 C (1K3 to EN ) storage temperature range Cooling forced ventilation, maximum inlet-air temperature 35 C Climatic conditions rel. humidity 5 85 % annual mean, no condensation 3K3 to EN Operating position vertical Operating conditions The power unit is designed as panel-mounting instrument according to: EN , pollution degree 2, overvoltage category Ü III Test voltage to EN Creepage distances Control section load circuit 5.5 mm, control section housing 5.5 mm instrument can be connected to SELV circuits. SELV = Separate Extra Low Voltage Housing Metal housing Weight approx. 9 kg Standard accessories 1 Operating Instructions B
3 Page 3/6 Data for inductor Inductor Dimensions Connection Weight Sales No. L = 0.5 mh / I N = 75A Inductor diameter : 155 mm by cable lugs with approx. 5kg 70/ Protection IP00 to EN height: 140 mm 8 mm bore diameter diameter of mounting hole: 10 mm EMC filter For the electrical supply to the power section Rated voltage and current Dimensions Weight Permissible ambient temperature Sales No. (L x W x H) 115/250 /440V AC, I n = 16A 255 x 50 x 130 mm approx. 4kg 40 C 70/ /250 /440V AC, I n = 32A 319 x 90 x 160 mm approx. 9 kg 40 C 70/ /250 /440V AC, I n = 63A 350 x 100 x 195 mm approx kg 40 C 70/ For the electrical supply to the control section (only requried if power section supplied from 400V AC) 115/250V AC, I n = 1A 80 x 45 x 30 mm approx. 120 g 40 C 70/ Dimensions Type ,2-0,2 8, ,2-0, ,1-0,1 8,6 Note: screws in power section (10mm a/f) may be tightened with max. 15 Nm!
4 Page 4/6 Connection diagram Relay Extra code optocoupler or Control section Power section Connection for Screw terminal X109 Detail Supply for control section L1 N (L2) Connection for Screw connections in power section Detail Protective earth PE Supply for power section U N(V) Inductor connection Load connection 1C C 1D D Connection for Screw terminal X102 Detail Current input (differential input) 1-2+ Voltage input (to ground) 3 ground 4+ External manual adjustment potentiometer 5 k 3 start (ground) 4 slider 5 end (+10V) Firing-pulse inhibit (inhibit input) I K approx. 1mA (break or make) 6 ground 7+ or Power level output 0 10V (V 2, P, I 2 ) I max approx. 2mA ground Resistance output 0 5V (R) I max approx. 2mA ground + 8 6
5 Page 5/6 Connection for Screw terminal X103 Detail Load fault output with relay contact rating 3A 230V AC resistive load relay de-energized on fault 1 n.o. (make) 2 n.c. (break) 3 common Load fault output with optocoupler Ic max 2mA V CEO max = 32 V 3 collector 1 emitter Single-phase operation Phase/N for Type / XXX-070-XXX and Type / XXX-070-XXX Single-phase operation Phase/Phase for Type / XXX-070-XXX Sales No
6 Page 6/6 Order details: Standard accessory 1 Operating Instructions Accessories (1) Basic type IGBT power converter (2) Basic type extension X 01 Basic version (3) Supply for control section V AC +15/-20%, 48 63Hz (only if power section also supplied from 115V AC) X V AC +15/-20 %, 48 63Hz (4) Supply for power section V AC +15/-20%, 48 63Hz X V AC +15/-20%, 48 63Hz X V AC +15/-20/%, 48 63Hz (5) Load voltage X VDC X VDC X VDC X V DC X V DC X V DC on request V DC on request (6) Load current X A DC (7) Extra code: fault signal output X 252 relay (changeover contact) 3A X 257 optocoupler (1) (2) (3) (4) (5) (6) (7) Order code / Order example / Storage inductor L = 0.5 mh / I N = 75 A, EMC filter: 115/250/400 V AC 16A, 32A or 63A, EMC filter: 115/250 V AC, I N = 1A Table for comparison Thyristor unit _A IPC unit 70A Quantity Weight Cost Quantity Weight Cost Power unit Transformer n/a n/a n/a Power inductor n/a n/a n/a Reactive-power compensation for phase-angle not required none control Filter to comply with EN and EN Synchronization for burst-firing operation n/a n/a n/a Total Fixed costs for reactive power per year none
Electronic Thermostat TE-1 Version according to EN
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 3639 Fulda, Germany Postal address: 3635 Fulda, Germany Phone: +49 661 63- Fax: +49 661 63-67 e-mail: mail@jumo.net Internet: www.jumo.net JUMO
More informationJUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationJUMO di 32 / di 08. Brief description. Block structure
M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 (0) 661 60 037 25 Fax: +49 (0) 661 60 036 81 EMail: mail@jumo.net Internet:
More informationJUMO dtrans T03 J, B, T Analog 2-wire transmitter with digital adjustment. JUMO dtrans T03 BU, TU Analog 3-wire transmitter with digital adjustment
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 3039 Fulda, Germany Postal address: 303 Fulda, Germany Phone: 49 1 0030 Fax: 49 1 00307 email: mail@jumo.net Internet: www.jumo.net JUMO Instrument
More informationJUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationJUMO dtrans T03 J, B, T Analog 2-wire transmitter with digital adjustment. JUMO dtrans T03 BU, TU Analog 3-wire transmitter with digital adjustment
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 3039 Fulda, Germany Postal address: 303 Fulda, Germany Phone: 49 1 0030 Fax: 49 1 00307 email: mail@jumo.net Internet: www.jumo.net JUMO Instrument
More informationdtrans Lf 01 µp transmitter / controller for electrolytic conductivity
M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 4, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: 49 66 6003-0 Fax: 49 66 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
More informationJUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)
JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
More informationInductive conductivity transmitter JUMO CTI-Junior
M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 (0) 661 60 03-7 25 Fax: +49 (0) 661 60 03-6 81 E-Mail: mail@jumo.net
More informationJUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter
JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: 49 661 60030 Fax: 49 661 6003607 Email: mail@jumo.net Internet: www.jumo.net JUMO
More informationJUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter
JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: 49 661 60030 Fax: 49 661 6003607 Email: mail@jumo.net Internet: www.jumo.net JUMO
More informationdtrans Az 01 µp Indicator/Controller for analytical measurement
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: 49 661 6003-0 Fax: 49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationJUMO dtrans T02 LCD programmable transmitter. B Operating Instructions 10.00/
JUMO dtrans T02 LCD programmable transmitter B 95.6522 Operating Instructions 10.00/00384955 Overview of operation JUMO dtrans T02 LCD Standard accessory 1 Type designation (1) Basic version 956522 programmable
More informationdtrans Rw 01 µp transmitter / controller for high-purity water
M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: 49 661 6003-0 Fax: 49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
More informationdtrans ph 01 µp transmitter / controller for ph value or redox voltage
M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: 49 661 6003-0 Fax: 49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
More informationdtrans Rd 01 µp Transmitter / Controller for redox potential (ORP)
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: 49 661 6003-0 Fax: 49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
More informationecotrans Lf 01/02 Transmitter / Switching Device for Conductivity Type B Operating Instructions 02.07/
ecotrans Lf 01/02 Transmitter / Switching Device for Conductivity Type 202731 B 20.2731.0 Operating Instructions 02.07/00435548 1 Notes 4 2 Identifying the device version 5 2.1 Type designation 5 3 Mounting
More informationJUMO ecotrans Lf 03 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature
Data Sheet 20272 Page /7 JUMO ecotrans Lf 0 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature Type 20272 Housing for DIN rail mounting (5 x 7.5 mm to DIN EN
More informationADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W
ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000
More informationSwitching power supplies CP range, Linear power supplies CP-L range. Content
CP range, Linear power supplies CP-L range Content Switching power supplies, primary switch mode, CP range Benefits and advantages... 136 Approvals... 137 Ordering details... 138 Technical data... 11 Dimensional
More informationdtrans ph 01 µp Transmitter / Controller for ph or redox potential (ORP)
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: 49 661 6003-0 Fax: 49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
More informationType: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description
Type: EASY719 AC RC Article No.: 274115 Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC Description 12 digital inputs 6 relay outputs LCD display Operating buttons Screw terminals
More informationTemperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
More informationEC centrifugal fan. backward curved, single inlet
RG56-AG7- ebm-papst Mulfingen GmbH & Co. KG Bachmühle 746 Mulfingen Phone: +49 798 - Fax: +49 798 - www.ebmpapst.com info@de.ebmpapst.com Nominal data Type Motor RG56-AG7- MG-FF Phase ~ Nominal voltage
More informationEN 50178, IEC
Type: DF51 322 1K5 Article No.: 289107 Sales text """Frequency inverter DF51(1,5 kw; 230V) Ordering information Rated voltage U e V Max. rated operational current I e A 7.1 Rated power for motors at 230
More informationIndoor, outdoor and duct resistance thermometers
Phone: 49 661 60030 Fax: 49 661 6003607 email: mail@jumo.net Phone: 44 1279 635533 Fax: 44 1279 635262 email: sales@jumo.co.uk 1800554JUMO Data Sheet 90.2523 Page 1/6 Indoor, outdoor and duct resistance
More informationMeasuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC
2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from
More information10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units
BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells
More informationData Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2
Data Sheet 066.8e Transducers for Active and Reactive Power EW 2.2 DGW 2.2 VGW 2.2 DUW 2.2 VUW 2.2 Application The E/DG/VG/DU/VU W 2.2 power transducers convert all forms of active and reactive power polarity
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More informationType: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description
Type: EASY719 DA RC Article.: 274117 Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationLINAX 4000L Continuous-line recorder
-48-852-0 4/2.99 1 to 4 line channels Format 144 mm x 144 mm, mounting depth 250 mm Combined recording table for roll chart (2 m) or fanfold chart (16 m) Measuring channels electrically isolated Rugged
More informationEC centrifugal fan. backward curved, single inlet
RG6-AB6- ebm-papst Mulfingen GmbH & Co. KG Bachmühle 6 Mulfingen Phone: + 798 8- Fax: + 798 8- www.ebmpapst.com info@de.ebmpapst.com Nominal data Type Motor RG6-AB6- MG-IF Phase ~ Nominal voltage [VAC]
More informationVoltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationDATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection
DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer
More informationPower supply CP-E 24/2.5
2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment
More informationPower supply CP-T 24/20.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationPower supply CP-E 24/20.0
2CDC 271 027 F0008 a OUTPUT L+, L+, L, L-: terminals output b INPUT L, N, PE: terminals input c 13-14: terminals - signalling contact d OUTPUT OK: green LED output voltage OK e OUTPUT LOW: red LED output
More informationCurrent monitoring relays CM-SRS.2 for single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationCurrent monitoring relays CM-SRS.1 for single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.1 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationEMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.
Electronic monitoring relay for voltage monitoring in three-phase networks INTERFACE Data sheet 102110_en_03 1 Description PHOENIX CONTACT - 09/2009 Features Increasingly higher demands are being placed
More informationMINI-PS AC/24DC/1.3
Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics
More informationElectronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact The CT-TGD.12 is an electronic time relay with the function pulse generator. It is from the CT-D range. With their MDRC profile
More informationTZIF 4. Current-to-Pulse Converter 10/ EN
TZIF 4 Current-to-Pulse Converter Conversion of direct current or voltage signals into a proportional pulse frequency Integration and average value formation of analog signals for quantity counting/remote
More informationEC centrifugal fan - RadiCal
R3G3-RO36-8 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 7938 8- Fax +49 7938 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court
More informationisolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems
T M 1 isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems Technical Bulletin NAE1012110 / 12.2011 isolr275 / AGH-LR Ground Fault Monitor
More informationProcess displays For standard signals, temperature, resistance measurement
Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions
More informationXR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)
XR1 Rotor Earth Fault Relay (May 2007) Manual XR1 (Revision New) Woodward Manual XR1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided
More informationValve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces:
Valve amplifier for proportional valves Type VT-MSPA2-1 RE 30228 Edition: 2014-01 Replaces: 2011-04 Component series 1X Suitable for controlling direct operated proportional directional valves without
More informationPower supply CP-T 24/10.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/10.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationThree-phase monitoring relays
2CDC 251 046 F0t08 Features Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance Threshold value for phase unbalance adjustable as absolute value Tripping delay can be adjusted
More informationT22. Torque transducer. Special features. Data sheet
T22 Torque transducer Special features - Nominal (rated) torques 0.5 Nm, 1 Nm, 2 Nm, 5 Nm, Nm, Nm, 50 Nm, 0 Nm, 0 Nm, 500 Nm and 1 knm - Nominal (rated) rotational speed up to 000 rpm (depending on measuring
More informationABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 042 F0t08 CM-PVS.31 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage Threshold values for over- and undervoltage are adjustable
More informationCM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC
2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance
More informationEMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004
Current Monitoring Relay Data Sheet 08/2004 Functions Structure Current monitoring of direct and alternating current in 1-phase networks with settable threshold values, starting override and response delay
More informationEC centrifugal fan - RadiCal
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 7938 8- Fax +49 7938 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA
More informationMeasuring current transformers of the W, W series
Measuring current transformers of the W, W -8000 series W(-8000)_D00078_01_D_XXEN/09.2015 Measuring current transformers of the W, W -8000 series Product description The highly sensitive W and W -8000
More informationQUINT-PS-24DC/24DC/10
QUINT-PS-24/24/10 QUINT - converter, primary switched mode, input: 24 V, output: 24 V /10 A INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description The QUINT - converter 24 V/10 A converts the voltage
More informationTransmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3.
TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex Transmitter for temperature and direct current variables in four-wire circuit Transmitters TEU 315 and TEU 325 are designed for direct and alternating voltage measurement
More informationEC centrifugal fan - RadiCal
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 798 8- Fax +49 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA
More informationPower supply CP-T 24/40.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/40.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More information02/11/2015
"Compact" range with display CD12 Part number 88970041 Green LCD with 4 lines of 18 characters and configurable backlighting More cost effective solution Industrial temperature range (-20 C +55 C) Analogue
More informationXR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)
XR1 Rotor Earth Fault Relay Manual XR1 (Revision C) Woodward Manual XR1 (EN) Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided by
More information"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting
Smart "Compact" range with display CD12 Smart Part number 88974043 "Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Type Input
More informationDIGEM f 96 x 48 EK. Applications. Description
3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel
More informationEC centrifugal fan. backward curved, single inlet
RG4-AM56- ebm-papst Mulfingen GmbH & Co. KG Bachmühle 746 Mulfingen Phone: +49 8 8- Fax: +49 8 8- www.ebmpapst.com info@de.ebmpapst.com Nominal data Type Motor RG4-AM56- MG-EA Phase ~ Nominal voltage [VAC]
More informationABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.
2CDC 251 052 F0t08 CM-MPS.23 2CDC 251 053 F0t08 CM-MPS.43 - relay status, timing - fault message - fault message Adjustment of the tripping delay t V Adjustment of the threshold value for overvoltage 6
More informationCoupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC
Data sheet Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC The CM-IVN serves to extend the measuring range of the insulation
More informationJUMO TYA 201 Single-Phase Thyristor Power Controller
JUMO TYA 201 Single-Phase Thyristor Power Controller 709061/8-01-032 709061/8-01-050 709061/8-01-100 709061/8-01-150 709061/8-01-200 709061/8-01-250 709061/8-01-020 Operating Manual 70906100T90Z001K000
More informationCoupling Relays and Converters
Overview Area of application In automation and control engineering it will always be necessary to work with analog signals. The interfaces for analog signals that have established themselves as the standard
More informationPower supply CP-E 12/10.0 Primary switch mode power supply Data sheet
2CDC 271 024 F0008 OUTPUT L+, L+, L-, L-: terminals - output INPUT L, N, PE: terminals - input OUTPUT OK: green LED - output voltage OK OUTPUT LOW: red LED - output voltage too low OUTPUT Adjust: potentiometer
More informationPower supply CP-T 48/20.0 Primary switch mode power supply
Data sheet Power supply CP-T 48/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More information27/04/2015
Modular Carril DIN 35 mm HIL Part number 84871120 Control of AC and DC currents Automatic recognition of AC/DC Measurement ranges from 2 ma to 10 A Choice between over and undercurrent True RMS measurement
More informationDATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC
DATASHEET - ETR4-51-A Timing relay, star-delta, 50 ms, 1W, 3-60s, 24-240VAC/DC Part no. ETR4-51-A Catalog No. 031884 Eaton Catalog No. XTTR6A60S51B EL-Nummer 0004133308 (Norway) Delivery program Product
More informationCP-T range Product group picture
Product group picture /1 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09 Table of contents CP-T range Product group picture /1 Table of contents /2 Benefits and advantages / Ordering details
More informationElectronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03
Electronic AC Load Series 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A Rev. 3.03 Electronic AC Loads, Series Interface overview RS-232 USB GPIB LAN System bus Analog / Analog isolated X X Standard
More informationPower supply CP-T 48/5.0 Primary switch mode power supply
Data sheet Power supply CP-T 48/5.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationMETRAClip87 and 88 Clamp Multimeters
3-349-795-03 1/7.14 Current and frequency measurement via clamp meter: METRAClip87: 1500 A AC TRMS and 1500 A DC METRAClip88: 2000 A AC TRMS and 3000 A DC Multimeter functions via connector sockets: V
More information02/11/2015
Smart "Compact" range with display CD20 Smart Part number 88974053 Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting Allow the use of the entire library of specific functions
More informationElectronic timer CT-TGD.22
2CDC 251 097 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection
More informationCustom "Compact" range with display CD20 Custom Part number
Custom "Compact" range with display CD20 Custom Part number 88974051 "Modular" versions designed for Custom application-specific functions (Custom functions) LCD with 4 lines of 18 characters and configurable
More informationEMD-FL-3V Phase Voltage Monitoring Relay INTERFACE. Data Sheet. Description
3-Phase Voltage Monitoring Relay INTERFACE Data Sheet PHOENIX CONTACT - 03/2006 Description Voltage monitoring in 3-phase networks with settable threshold values, settable response delay, monitoring of
More informationThree-phase monitoring relays CM-PFE and CM-PFE.2
Data sheet Three-phase monitoring relays CM-PFE and CM-PFE.2 The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251
More informationValve amplifier for proportional pressure valves
Valve amplifier for proportional pressure valves Type VT-MRMA1-1 RE 30214 Edition: 2017-03 Replaces: 04.13 Component series 1X Analog, modular design Suitable for controlling a direct current motor-operated
More informationMCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description
Voltage transducer for AC voltages TERFACE Data sheet 006_en_0 PHOENIX CONTACT 00-0- Description The MCR voltage transducer measures AC voltages in several signal ranges from 0... ±4 V AC to 0... ±30 V
More informationTRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:
Extract from the online catalog TRIO-PS/1AC/24DC/ 5 Order No.: 2866310 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 5 A Commercial data EAN 4046356046640 Pack 1 pcs. Customs
More informationAC/DC Power Supply Series APPLICATION NOTE
-350 + -700 AC/DC Power Supply Series APPLICATION NOTE NV350_NV700 App notes 69498 12.doc Document Number 69498 Page 1 of 17 1. INPUT... 3 AC INPUT LINE REQUIREMENTS... 3 2. DC OUTPUT... 3 OUTPUT VOLTAGES...
More informationPower supply CP-E 48/5.0 Primary switch mode power supply Data sheet
2CDC 271 028 F0008 OUTPUT L+, L+, L-, L-: terminals - output Features Rated output voltage 48 V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output current 5 A Rated
More informationT22. Data Sheet. Torque transducer. Special features. Installation example with two bellows couplings. B en
T22 Torque transducer Data Sheet Special features - Nominal (rated) torques N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m, 00 N m and 1 kn m - Nominal (rated) rotational speeds of 9000 rpm to 16 000 rpm
More informationABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.
2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault
More informationAnalog outputs (option) Outputs 1 + 2: 0(4) - 20 ma or 0-10 V
sales@jumo.co.uk info@jumo.us Page 1/12 JUMO AQUIS 500 Ci Transmitter/controller for inductive conductivity, concentration and temperature Brief description The instrument is used for the inductive measurement
More informationCoupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC
Data sheet Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC The CM-IVN serves to extend the measuring range of the insulation
More informationPower supply CP-E 24/0.75
2CDC 271 016 F0t06 a OUTPUT L+, L : terminals output b INPUT L, N, PE: terminals input c LOW: red LED output voltage too low d OK: green LED output voltage OK e OUTPUT Adjust: rotary potentiometer output
More informationInductive Conductivity/Concentration and Temperature Transmitter with switch contacts
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationOvercurrent Protection / 7SJ45
Overcurrent Protection / SJ SIPROTEC easy SJ numerical overcurrent protection relay powered by CTs Fig. / Description SIPROTEC easy SJ numerical overcurrent protection relay powered by current transformers
More informationElectronic timer CT-SDS.22
CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication
More informationPower supply CP-E 24/2.5
2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment
More informationCurrent monitor Type C 551
Current monitor Type C 551 Relay for current monitoring, single-phase Monitoring AC and DC for overcurrent or undercurrent 1 yellow LED for indication of the relay state 1 green LED for indication of the
More informationISOMETER iso685- -B. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Preliminary data sheet
Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Preliminary data sheet iso685-x-b_d00177_04_d_xxen/04.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems
More informationCP-T range Benefits and advantages
Benefits and advantages Characteristics Rated output voltages V, V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output currents 5 A, 10 A, A, A Rated output powers
More information