Agilent N7509A Waveform Generation Toolbox Application Program

Size: px
Start display at page:

Download "Agilent N7509A Waveform Generation Toolbox Application Program"

Transcription

1 Agilent N7509A Waveform Generation Toolbox Application Program User s Guide Second edition, April 2005 Agilent Technologies

2 Notices Agilent Technologies, Inc No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Agilent Technologies, Inc. as governed by United States and international copyright laws. Manual Part Number N Edition Second edition, April 2005 Printed in USA Agilent Technologies, Inc Fountaingrove Pkwy Santa Rosa, CA Warranty The material contained in this document is provided as is, and is subject to being changed, without notice, in future editions. Further, to the maximum extent permitted by applicable law, Agilent disclaims all warranties, either express or implied, with regard to this manual and any information contained herein, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Agilent shall not be liable for errors or for incidental or consequential damages in connection with the furnishing, use, or performance of this document or of any information contained herein. Should Agilent and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms, the warranty terms in the separate agreement shall control. Technology Licenses The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license. Restricted Rights Legend If software is for use in the performance of a U.S. Government prime contract or subcontract, Software is delivered and licensed as Commercial computer software as defined in DFAR (June 1995), or as a commercial item as defined in FAR 2.101(a) or as Restricted computer software as defined in FAR (June 1987) or any equivalent agency regulation or contract clause. Use, duplication or disclosure of Software is subject to Agilent Technologies standard commercial license terms, and non-dod Departments and Agencies of the U.S. Government will receive no greater than Restricted Rights as defined in FAR (c)(1-2) (June 1987). U.S. Government users will receive no greater than Limited Rights as defined in FAR (June 1987) or DFAR (b)(2) (November 1995), as applicable in any technical data. Safety Notices CAUTION A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. WARNING A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met.

3 Contents 1 INTRODUCTION 6 2 SYSTEM REQUIREMENTS 6 3 INSTALLATION 6 4 LICENSING 7 5 SYSTEM STATE FILES 7 6 STARTUP 8 7 MENU BAR File Menu Settings Menu Help Menu 10 8 BUTTON BAR 11 9 GENERAL CONTROLS BOX GRAPH CONTROLS WAVEFORM GENERATION CONTROLS AM Generator Form FM Generation Form PM Generator Form Multi-Tone Generator Form Pulse Generator Form Simple Pulse Linear Chirp Barker Code Frank Code Doppler Chirp Generator Form Custom Download IF Mode Creating and Playing a Sequence RF SOURCE CONTROL 28 N7509A User s Guide 3

4 4 N7509A User s Guide

5 Agilent N7509A Waveform Generation Tool Application Program User s Guide 1 General Information Agilent Technologies 5

6 1 General Information 1 INTRODUCTION The N7509A WGT Application program provides a user-friendly interface to the waveform generation toolbox library, and to the E8267C/D PSG Vector Signal Generator (VSG) and the N6030A Arbitrary Waveform Generator (AWG). The WGT library is a set of routines that use math techniques to generate waveforms as I/Q arrays for use in the AWG. The application allows a user to generate the following waveform types: AM FM PM Multi-tone Various types of Pulse waveforms Chirp Whenever a waveform types is generated, it is automatically downloaded to the AWG if one is connected and the application is not in simulation mode (more on simulation mode later). Users may download custom waveform data to the AWG. This may be either data that was generated by this or another application. Users may generate waveform sequences and have the AWG play them. The application provides a means to control the output of the VSG. 2 SYSTEM REQUIREMENTS 3 INSTALLATION This application must be installed on a PC running the Microsoft Windows XP Professional operating system, or Microsoft Windows 2000 with the.net Framework installed. The application requires that the MATLAB run-time libraries be installed (included). There should be at least 240 MB of disk space available to accommodate both the application and the MATLAB run-time libraries. This application is capable of generating large waveforms. For this reason it is recommended that the host computer have a 2.4 GHz (or higher) Pentium 4 processor, and at least 512 MB of RAM. Insert the installation CD into the CD-ROM drive. If the installation utility program does not start automatically, start it by running WgtInstall.exe. The installation window illustrated in Figure 1 will be displayed. To install the N7509A WGT application, click the button labeled "Install Agilent N7509A Waveform Generation Toolbox Application". If the MATLAB run-time libraries 6 N7509A User s Guide

7 General Information 1 are not already installed, do so by clicking the button labeled "Install MATLAB 7.0 Run-Time Libraries". Click the Exit button when done. Note that the installation window contains the host ID to be used when the Software Entitlement Certificate is redeemed in order to obtain a license. Figure 1 Installation Form 4 LICENSING This software must be licensed in order for it to be fully functional. To obtain a license, follow the instructions listed on the Software Entitlement Certificate that came with your software. The software may still be used without a license but it will be restricted to simulation mode. It will be able to generate waveforms and display them on the graph, but it will not be able to talk to instruments. It will also not be able to generate binary waveform files. 5 SYSTEM STATE FILES At any time, the system state can be saved to and restored from "system state" files. The system state is a snapshot of the values of all the variables in the application. These variables include the waveform generator parameters and application settings. The default extension for system state files is wgt. N7509A User s Guide 7

8 1 General Information There are three types of system state files as described in Table 1. Table 1 System State File Types System State File Type File Name File Location Description Default _DefaultState_.wgt Agilent\N7509A WGT in the user's Application Data folder. Current _CurrentState_.wgt Agilent\N7509A WGT in the user's Application Data folder. Custom < defined by user > Defined by the user. The default location is Agilent\N7509A WGT in the user's My Documents folder. Contains system defaults as defined by the user or organization. There is only one Default system state file per user. The Current system state file is automatically created/updated whenever the application is exited. When the application is restarted, the system state is initialized from the Current state file so that the user may continue from where s/he left off. There is only one Current system state file per user. Contains the user's custom system state. Whenever the user opens or saves to a custom system state file, that file becomes the "established" custom system state file. There may be many custom system state files. 6 STARTUP When the application is started, it reads the system state from a "current" system state file (see Table 1). The current system state file is created the first time the application is exited. After that it is updated each time the application is exited. This ensures that the user will be able to continue from where she or he left off the last time the application was used. If there is no current system state file, the application will initialize the system state using the default system state file (see Table 1). If there is no default system state file, the application creates one using the "default default" values, that is, the values encoded in the software itself. This happens the very first time a user runs the application. 8 N7509A User s Guide

9 General Information 1 7 MENU BAR An alternative way to start the application and to immediately load a custom system state file is to double-click the name of a custom system state file in Windows Explorer. Also, the full path to a custom system state file may be used as the only parameter (unquoted) in a command line that starts the application. The instruments are also initialized at startup if they are present. The menu bar at the top of the N7509A WGT application form contains three drop-down menus - File, Settings and Help. 7.1 File Menu The File menu contains eight items. They are described in Table 2. Table 2 File Menu Items File Menu Item Shortcut Key Description New Ctrl+N Initializes the system state from the defaults system state file. Save Ctrl+S Allows the user to save the current system state to a user's custom system state file. If the user has not yet established a custom system state file, Save will behave as Save As. Save As Ctrl+A Allows the user to save the current system state to a specific file. This will establish the file as the user's custom system state file. Open Ctrl+O Allows the user to open a system state file and thereby update the current system state to the values found in the file. This will establish the file as the user's custom system state file. Save As Default Restore Default Preset Exit Ctrl+X Closes the application. Allows the user to establish the current system state as the default. Sets the system state to the default. This is functionally equivalent to the New menu item. A sub-menu that provides various items for presetting hardware. 7.2 Settings Menu The Settings menu contains eight items They are described in Table 3. N7509A User s Guide 9

10 1 General Information Table 3 Settings Menu Items Settings Menu Item Description Default Setting Save I/Q Binary Data IF Mode Enable Arb Corrections RF Power Off on Exit External Reference Clock External Sample Clock RF Source Config Q Arb Config If checked, I and Q data for generated waveforms are stored to binary files in the user's current working directory. If checked, the application will operate in IF mode If checked, the application will apply correction to the I/Q or IF data before downloading the AWG. If checked and if the application is not in simulation mode, the instruments are reset when the application exits. When checked, the AWG is instructed to use the external reference clock. When checked, the AWG is instructed to use the external sample clock. Allows the user to edit the configuration string that is sent to the VSG when it is initialized. Allows the user to edit the configuration string that is sent to the AWG when it is initialized. Checked Unchecked Checked Checked Unchecked Unchecked "GPIB0::19::INSTR" "PXI4::12::0::INSTR" 7.3 Help Menu The Help menu contains one item. It is described in Table 4. Table 4 Help Menu Items Help Menu Item About Description When selected, a form window is displayed that provides information about the application. 10 N7509A User s Guide

11 General Information 1 When the About item is selected, the About window illustrated in Figure 2 is displayed. Note that it contains the host ID to be used when the Software Entitlement Certificate is redeemed in order to obtain a license. Figure 2 About Window 8 BUTTON BAR The button bar contains three buttons - New, Open and Save. They are described in Table 5. Table 5 Button Name New Button Bar Icon Description This button behaves exactly like the New item in the File menu. Open This button behaves exactly like the Open item in the File menu. Save This button behaves exactly like the Save item in the File menu. N7509A User s Guide 11

12 1 General Information 9 GENERAL CONTROLS BOX The General Controls group box is a rectangle near the top of the GUI that contains five controls. They are described in Table 6. Table 6 General Controls General Control Name Description Default Waveform Type Simulation Mode Generate Scenario Loop Count Calibrate This control allows the user to select the type of waveform to be generated. Custom downloading and RF source control are also selected here. When this is checked, the application doesn't attempt to talk to either the VSG or the AWG. Enables the Generate Scenario mode where users may create waveform sequences and have the AWG play them. This control is visible only when the Generate Scenario box is checked. It provides a way for the user to set the loop count for a waveform when sequencing. When pressed, this button causes a calibration of the VSG. AM Generator Unchecked Unchecked N7509A User s Guide

13 General Information 1 10 GRAPH CONTROLS There are four controls under the graph that control graph-related settings. They are described in Table 7. Table 7 Graph Controls Graph Control Name Description Default Log 10 Scale When checked, waveforms are graphed in base 10 logarithmic scaling. Checked Auto Scale When checked, the graph auto scales the full waveform. Unchecked Clear When pressed, this button clears the graph. 1 Expand/Contract If the graph is in its normal, contracted mode, this button is labeled "Expand". When the graph is in the expanded mode it is labeled "Contract". Pressing this button toggles the graph between the expanded and contracted mode WAVEFORM GENERATION CONTROLS The Waveform Type selector allows the user to select from the following list of waveform generators, custom download and the RF source controller: AM Generator FM Generator PM Generator Multi-Tone Generator Pulse Generator Chirp Generator Custom Download RF Source Control NOTE The default values listed in the generator forms tables below are "default default" values, that is, the values encoded in the program code. The user may redefine the default system state at any time by selecting Save As Default in the File menu AM Generator Form When the AM Generator is selected, the following parameter list is displayed: N7509A User s Guide 13

14 1 General Information Table 8 AM Generation Form Parameter List Parameter Name Description Units Default Value AM Rate The frequency of the modulation Hertz 10 MHz AM Depth The power of the sidebands Decibels 23 db Sample Clock The frequency of the sampling clock Hertz 1.25 Ghz Number of Points The number of points in each vector (read only) Figure 3 shows the AM Generator form. Figure 3 AM Waveform Generation Form When the Generate Signal button is pressed the application uses the parameter values to generate an AM waveform. The number of points in the waveform is displayed and the waveform is graphed. If the application is connected to an AWG, and if the application has the proper license, and if the Simulation Mode box is not checked, the waveform is downloaded to the AWG FM Generation Form When the FM Generator is selected, the following parameter list is displayed: 14 N7509A User s Guide

15 General Information 1 Table 9 FM Generation Form Parameter List Parameter Name Description Units Default Value FM Rate The frequency of the modulated signal Hertz 1 MHz FM Deviation The deviation of the modulated signal Hertz 2.4 MHz Sample Clock The frequency of the sampling clock Hertz 1.25 GHz Data Size The size of the waveform (read only) Figure 4 shows the FM Generator form. Figure 4 FM Waveform Generation Form When the Generate Signal button is pressed the application uses the parameter values to generate a FM waveform. The size of the waveform is displayed and the waveform is graphed. If the application is connected to an AWG, and if the application has the proper license, and if the Simulation Mode box is not checked, the waveform is downloaded to the AWG PM Generator Form When the PM Generator is selected, the following parameter list is displayed: N7509A User s Guide 15

16 1 General Information Table 10 PM Generator Form parameter list Parameter Name Description Units Default Value PM Rate PM Deviation Sample Size Data Size The frequency of the modulating signal The deviation of the modulating signal The frequency of the sampling clock The size of the waveform (read only) Hertz 1 MHz Radians Rad Hertz 1.25 GHz Figure 5 shows the PM Generator form. Figure 5 PM Waveform Generator Form When the Generate Signal button is pressed the application uses the parameter values to generate a PM waveform. The size of the waveform is displayed and the waveform is graphed. If the application is connected to an AWG, and if the application has the proper license, and if the Simulation Mode box is not checked, the waveform is downloaded to the AWG. 16 N7509A User s Guide

17 General Information Multi-Tone Generator Form When the Multi-Tone Generator is selected, the following parameter list is displayed: Table 11 Multi-Tone Generator Form Parameter List Parameter Name Description Units Default Value Start Frequency The frequency of the first tone Hertz -400 MHz Number of Tones The number of tones in the waveform Fbin The resolution frequency Hertz 10 KHz Tone Spacing The tone spacing Hertz 100 KHz Fs The frequency of the sampling clock Hertz 1.25 GHz Notch Width The width, if any, of the notch (for NPR) Hertz 50 MHz Notch Offset Random Seed IQ Backoff From Full Scale Power The frequency of the center of the notch, if any, relative to the carrier frequency The seed for the random number generator as a prime integer Hertz 100 MHz (Unavailable in this revision) Decibels 0 db Figure 6 shows the Multi-Tone Generator form. N7509A User s Guide 17

18 1 General Information Figure 6 Multi-Tone Waveform Generator form When the Generate Signal button is pressed the application uses the parameter values to generate a multi-tone waveform. The size of the waveform is displayed and the waveform is graphed. If the application is connected to an AWG, and if the application has the proper license, and if the Simulation Mode box is not checked, the waveform is downloaded to the AWG Pulse Generator Form When the Pulse Generator is selected, the following parameter list is displayed: Table 12 Pulse Generator Form Parameter List Parameter Name Description Units Default Value Pulse Width The pulse width Seconds 50 ns PRI The pulse repetition interval Seconds 0.5 µs Rise Time The pulse rise time interval, in multiples of 10 ns Seconds 10 ns Fall Time The pulse fall time interval, in multiples of 10 ns Seconds 10 ns Sample Clock The frequency of the sampling clock Hertz 1.25 Ghz Mod on Pulse The pulse type --- Barker Code Frequency Offset The frequency offset Hertz 0 18 N7509A User s Guide

19 General Information Simple Pulse Figure 7 shows the Pulse Generator form when the pulse type is simple pulse. Figure 7 Pulse Waveform Generator form - Simple Pulse When the Generate Signal button is pressed the application uses the parameter values to generate a simple pulse waveform. The waveform is graphed. If the application is connected to an AWG, and if the application has the proper license, and if the Simulation Mode box is not checked, the waveform is downloaded to the AWG Linear Chirp In the Pulse Generator form, when the selected pulse type is Linear Chirp the following additional parameter is displayed: Table 13 Linear Chirp additional parameter Parameter Name Description Units Default Value Linear Chirp Deviation Frequency range over which the chirp moves during the pulse width period. Hertz 60 MHz Figure 8 shows the Pulse Generator form when the pulse type is Linear Chirp. N7509A User s Guide 19

20 1 General Information Figure 8 Pulse Waveform Generator form - Linear Chirp When the Generate Signal button is pressed the application uses the parameter values to generate a linear chirp pulse waveform. The waveform is graphed. If the application is connected to an AWG, and if the application has the proper license, and if the Simulation Mode box is not checked, the waveform is downloaded to the AWG Barker Code In the Pulse Generator form, when the selected pulse type is Barker Code the following additional parameter is displayed: Table 14 Barker Code additional parameter Parameter Name Description Units Default Value Barker Code Length Number of phase sub-pulses in the pulse bit Barker Figure 9 shows the Pulse Generator form when the pulse type is Barker Code. 20 N7509A User s Guide

21 General Information 1 Figure 9 Pulse Waveform Generator form -Barker Code When the Generate Signal button is pressed the application uses the parameter values to generate a Barker code pulse waveform. The waveform is graphed. If the application is connected to an AWG, and if the application has the proper license, and if the Simulation Mode box is not checked, the waveform is downloaded to the AWG Frank Code In the Pulse Generator form, when the selected pulse type is Frank Code the following additional parameter is displayed: Table 15 Frank Code additional parameter Parameter Name Description Units Default Value Order for Polyphase Code Square root of the number of phase sub-pulses in the pulse Figure 10 shows the Pulse Generator form when the pulse type is Frank Code. N7509A User s Guide 21

22 1 General Information Figure 10 Pulse Generator Form When Pulse Type is Frank Code When the Generate Signal button is pressed the application uses the parameter values to generate a Frank code pulse waveform. The waveform is graphed. If the application is connected to an AWG, and if the application has the proper license, and if the Simulation Mode box is not checked, the waveform is downloaded to the AWG Doppler In the Pulse Generator form, when the selected pulse type is Doppler the following additional parameter is displayed: Table 16 Doppler additional parameter Parameter Name Description Units Default Value Doppler Frequency Value of the frequency shift of the pulse Hertz 100 Hz Figure 11 shows the Pulse Generator form when the pulse type is Doppler: 22 N7509A User s Guide

23 General Information 1 Figure 11 Pulse Waveform Generator Form - Doppler When the Generate Signal button is pressed the application uses the parameter values to generate a Doppler pulse waveform. The waveform is graphed. If the application is connected to an AWG, and if the application has the proper license, and if the Simulation Mode box is not checked, the waveform is downloaded to the AWG Chirp Generator Form When the Chirp Generator is selected, the following parameter list is displayed: Table 17 Chirp Generator parameter list Parameter Name Description Units Default Value Pulse Width The pulse width Seconds 1 µs Sample Clock The frequency of the sampling clock Hertz 1.25 GHz PRI The pulse repetition interval Seconds 10 µs Chirp Frequency Deviation Frequency range over which the chirp moves during the pulse width period Hertz 1 Ghz Rise Time The rise time interval, in multiples of 10 ns Seconds 40 ns N7509A User s Guide 23

24 1 General Information Table 17 Chirp Generator parameter list Parameter Name Description Units Default Value Fall Time The fall time interval, in multiples of 10 ns Seconds 40 ns Chirp Type The chirp type --- Inverted V-chirp Frequency Offset The frequency offset Hertz 0 Figure 12 shows the Chirp Generator form. Figure 12 Chirp Waveform Generator Form When the Generate Signal button is pressed the application uses the parameter values to generate a chirp waveform. The waveform is graphed. If the application is connected to an AWG, and if the application has the proper license, and if the Simulation Mode box is not checked, the waveform is downloaded to the AWG Custom Download When Custom Download is selected, the following parameter list is displayed: 24 N7509A User s Guide

25 General Information 1 Table 18 Custom Download parameter list Parameter Name Description Units Default Value Channel 1 Path and name of the file containing I data --- (blank) Channel 2 Path and name of the file containing Q data --- (blank) Figure 13 shows the Custom Download form. Figure 13 Custom Download Form Click in the Channel 1 box to open a file containing I data for channel 1. Click in the Channel 2 box to open a file containing Q data for channel 2. The boxes will then be populated with the full path and file name of the respective files. When both boxes are populated, the Play button will be enabled. When the Play button is pressed the application loads the I and Q data from the specified files. The waveform associated with the data is graphed. If the application is connected to an AWG, and if the application has the proper license, and if the Simulation Mode box is not checked, the waveform is downloaded to the AWG. N7509A User s Guide 25

26 1 General Information 11.8 IF Mode When the IF Mode item in the Settings menu is checked, the application operates in IF Mode. The following additional parameter is displayed for all waveform types. Table 19 IF Mode Additional Parameter Parameter Name Description Units Default Value IF Freq The intermediate frequency Hertz 300 MHz Figure 14 shows the GUI in IF mode with the AM Generator selected. Figure 14 AM Generator form in IF Mode 11.9 Creating and Playing a Sequence When the Generate Scenario box is checked, the application enters the Generate Scenario mode. In this mode the user can create and play a sequence of waveforms. Figure 15 shows the GUI in Generate Scenario mode with the AM Generator selected. Note that any waveform type may be used in the generation of sequences. 26 N7509A User s Guide

27 General Information 1 Figure 15 Generate Scenario Mode When the Load Waveform button is pressed, a waveform is generated for the selected waveform type and is downloaded to the AWG. The waveform's information is listed in the Sequence List box on the right side of the form. A user will typically generate multiple waveforms, each of which will appear in the list. Once the user has generated all the necessary waveforms, the Load Sequence and Play button is pressed to tell the AWG to load and play the sequence. N7509A User s Guide 27

28 1 General Information 12 RF SOURCE CONTROL When the RF Source Control is selected in the Waveform Type control, the following parameter list is displayed: Table 20 RF source control parameter list Parameter Name Description Units Default Value Frequency The frequency of the output signal Hertz 10 GHz Power The power of the output signal dbm -5 dbm RF Out On or Off --- Off WB IQ Modulator On or Off --- Off Figure 16 shows the RF Source Control form. Figure 16 RF Source Control Form When the GO button is pressed the application sends the parameter values to the VSG. If the application is not connected to a VSG, or if the Simulation Mode box is checked, the parameter controls and the GO button are disabled. 28 N7509A User s Guide

InfiniiMax Spice Models for the N5381A and N5382A Probe Heads

InfiniiMax Spice Models for the N5381A and N5382A Probe Heads InfiniiMax Spice Models for the N5381A and N5382A Probe Heads User s Guide Agilent Technologies Notices Agilent Technologies, Inc. 2005 No part of this manual may be reproduced in any form or by any means

More information

Pin Tool. Assembly Guide. For Research Use Only. Not for use in diagnostic procedures. Original Instructions

Pin Tool. Assembly Guide. For Research Use Only. Not for use in diagnostic procedures. Original Instructions Pin Tool Assembly Guide For Research Use Only. Not for use in diagnostic procedures. Original Instructions Notices Agilent Technologies, Inc. 2017 No part of this manual may be reproduced in any form or

More information

Agilent N2902A 9000 Series Oscilloscope Rack Mount Kit

Agilent N2902A 9000 Series Oscilloscope Rack Mount Kit Agilent N2902A 9000 Series Oscilloscope Rack Mount Kit Installation Guide Agilent Technologies Notices Agilent Technologies, Inc. 2009 No part of this manual may be reproduced in any form or by any means

More information

User Guide. Keysight N6850A Broadband Omnidirectional Antenna

User Guide. Keysight N6850A Broadband Omnidirectional Antenna User Guide Keysight N6850A Broadband Omnidirectional Antenna Notices Keysight Technologies, Inc. 2012-2015 No part of this manual may be reproduced in any form or by any means (including electronic storage

More information

Agilent ParBERT Measurement Software. Fast Eye Mask Measurement User Guide

Agilent ParBERT Measurement Software. Fast Eye Mask Measurement User Guide S Agilent ParBERT 81250 Measurement Software Fast Eye Mask Measurement User Guide S1 Important Notice Agilent Technologies, Inc. 2002 Revision June 2002 Printed in Germany Agilent Technologies Herrenberger

More information

Agilent Technologies. E8257D/67D, E8663D PSG Signal Generators. Key Reference. Agilent Technologies

Agilent Technologies. E8257D/67D, E8663D PSG Signal Generators. Key Reference. Agilent Technologies Agilent Technologies E8257D/67D, E8663D PSG Signal Generators Key Reference Agilent Technologies Notices Agilent Technologies, Inc. 2006-2010 No part of this manual may be reproduced in any form or by

More information

Agilent X-Series Signal Analyzer This manual provides documentation for the following X-Series Analyzer: CXA Signal Analyzer N9000A

Agilent X-Series Signal Analyzer This manual provides documentation for the following X-Series Analyzer: CXA Signal Analyzer N9000A Agilent X-Series Signal Analyzer This manual provides documentation for the following X-Series Analyzer: CXA Signal Analyzer N9000A N9000A CXA Functional Tests Notices Agilent Technologies, Inc. 2006-2008

More information

Keysight U7238C/U7238D MIPI D-PHY SM Test App. Methods of Implementation

Keysight U7238C/U7238D MIPI D-PHY SM Test App. Methods of Implementation Keysight U7238C/U7238D MIPI D-PHY SM Test App Methods of Implementation 2 MIPI D-PHY Conformance Testing Methods of Implementation Notices Keysight Technologies 2008-2010, 2014-2017 No part of this manual

More information

Key Reference. Agilent Technologies E8257D/67D PSG Signal Generators. Manufacturing Part Number: E Printed in USA July 2007

Key Reference. Agilent Technologies E8257D/67D PSG Signal Generators. Manufacturing Part Number: E Printed in USA July 2007 Agilent Technologies E8257D/67D PSG Signal Generators This guide applies to the following signal generator models: E8267D PSG Vector Signal Generator E8257D PSG Analog Signal Generator Due to our continuing

More information

Keysight 86205B RF Bridge

Keysight 86205B RF Bridge Keysight 86205B RF Bridge Operating and Service Manual Notices Keysight Technologies 2011, 2014 No part of this manual may be reproduced in any form or by any means (including electronic storage and

More information

Agilent E5505A Phase Noise Measurement System

Agilent E5505A Phase Noise Measurement System Agilent E5505A Phase Noise Measurement System Notice: This document contains references to Agilent. Please note that Agilent s Test and Measurement business has become Keysight Technologies. For more information,

More information

Agilent X-Series Signal Analyzer

Agilent X-Series Signal Analyzer Agilent X-Series Signal Analyzer This manual provides documentation for the following X-Series Analyzers: MXA Signal Analyzer N9020A EXA Signal Analyzer N9010A N9079A TD-SCDMA with HSPA/8PSK Measurement

More information

Keysight X-Series Signal Analyzers

Keysight X-Series Signal Analyzers Keysight X-Series Signal Analyzers This manual provides documentation for the following models: N9040B UXA N9030B PXA N9020B MXA N9010B EXA N9000B CXA N9068C Phase Noise Measurement Application Measurement

More information

Agilent 5DX Series 2L, 3, and 5000 X-ray Safety Test Report

Agilent 5DX Series 2L, 3, and 5000 X-ray Safety Test Report Agilent 5DX Series 2L, 3, and 5000 X-ray Safety Test Report To be completed by the EMG RADIATION SAFETY & REGULATORY ENGINEER: System SN: Test Date: Month Day Year Survey Report Type: Net X-ray emission:

More information

Keysight X-Series Signal Analyzers

Keysight X-Series Signal Analyzers Keysight X-Series Signal Analyzers This manual provides documentation for the following Analyzers: PXA Signal Analyzer N9030A EXA Signal Analyzer N9010A MXE EMI Receiver N9038A MXA Signal Analyzer N9020A

More information

Agilent N2740A Education Training Kit for 1000 Series Oscilloscopes

Agilent N2740A Education Training Kit for 1000 Series Oscilloscopes Agilent N2740A Education Training Kit for 1000 Series Oscilloscopes Lab Manual A Notices Agilent Technologies, Inc. 2008 No part of this manual may be reproduced in any form or by any means (including

More information

SPM-50 RF Spectrum Power Meter PC Software User Manual

SPM-50 RF Spectrum Power Meter PC Software User Manual SPM-50 RF Spectrum Power Meter PC Software User Manual Shineway Technologies, Inc. Notices Copyright 2014, ShinewayTech, All rights reserved. No part of this manual may be reproduced in any form or by

More information

Agilent 5DX System. X-ray Safety Test Procedure. for use with Software Release 8.20 and later

Agilent 5DX System. X-ray Safety Test Procedure. for use with Software Release 8.20 and later Agilent 5DX System for use with Software Release 8.20 and later Agilent Technologies, Inc. 1996-2008 Agilent Safety and Regulatory Information: Restricted Rights Notice If software is for use in the performance

More information

Keysight X-Series Signal Analyzer

Keysight X-Series Signal Analyzer Keysight X-Series Signal Analyzer This manual provides documentation for the following Analyzers: N9040B UXA N9030B PXA N9020B MXA N9010B EXA N9000B CXA N9063C Analog Demod Measurement Application Measurement

More information

N2790A Differential Voltage Probe

N2790A Differential Voltage Probe N2790A Differential Voltage Probe User s Guide For Safety, Regulatory, and publishing information, see the pages at the back of this book. Copyright Agilent Technologies 2009 All Rights Reserved. A Contents

More information

Option 10 Complex Modulation

Option 10 Complex Modulation User Guide Option 10 Complex Modulation Waveform Download Software for the MG3690A/B/C Series Synthesized Signal Generator Anritsu Company 490 Jarvis Drive Morgan Hill, CA 95037-2809 USA Part Number: 10370-10327

More information

Key Reference. Agilent Technologies E8663B Analog Signal Generator

Key Reference. Agilent Technologies E8663B Analog Signal Generator Agilent Technologies E8663B Analog Signal Generator For the latest revision of this guide, go to http://www.agilent.com/find/e8663b and click Product Library. Manufacturing Part Number: E8663-90004 Printed

More information

HP 86290B RF PLUG-IN GHz HEWLETT PACKARD

HP 86290B RF PLUG-IN GHz HEWLETT PACKARD OPERATING AND SERVICE MANUAL. HP 86290B RF PLUG-IN 2.0-18.6 GHz HEWLETT PACKARD COPYRIGHT AND DISCLAIMER NOTICE Copyright - Agilent Technologies, Inc. Reproduced with the permission of Agilent Technologies

More information

E2621A and E2622A Probe Adapters for Infiniium Oscilloscopes. User s Guide. Publication number E September 2002

E2621A and E2622A Probe Adapters for Infiniium Oscilloscopes. User s Guide. Publication number E September 2002 User s Guide sa Publication number E2621-92003 September 2002 For Safety, Regulatory, and publishing information, see the pages at the back of this book. Copyright Agilent Technologies 1999-2002 All Rights

More information

Large-Signal S-Parameter Simulation

Large-Signal S-Parameter Simulation Large-Signal S-Parameter Simulation May 2003 Notice The information contained in this document is subject to change without notice. Agilent Technologies makes no warranty of any kind with regard to this

More information

PXA Configuration. Frequency range

PXA Configuration. Frequency range Keysight Technologies Making Wideband Measurements Using the Keysight PXA Signal Analyzer as a Down Converter with Infiniium Oscilloscopes and 89600 VSA Software Application Note Introduction Many applications

More information

Large-Signal S-Parameter Simulation

Large-Signal S-Parameter Simulation Large-Signal S-Parameter Simulation September 2004 Notice The information contained in this document is subject to change without notice. Agilent Technologies makes no warranty of any kind with regard

More information

Agilent 2-Port and 4-Port PNA-X Network Analyzer

Agilent 2-Port and 4-Port PNA-X Network Analyzer Agilent 2-Port and 4-Port PNA-X Network Analyzer N5244A - MHz to 43.5 GHz N5245A - MHz to 5. GHz with Option H29 Data Sheet and Technical Specifications Documentation Warranty THE MATERIAL CONTAINED IN

More information

Keysight N9051A Pulse Measurement Software

Keysight N9051A Pulse Measurement Software Keysight N9051A Pulse Measurement Software Software Version 2.2 Notice: This document contains references to Agilent. Please note that Agilent s Test and Measurement business has become Keysight Technologies.

More information

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009 User s Guide Publication number 34134-90001 April 2009 For Safety information, Warranties, Regulatory information, and publishing information, see the pages at the back of this book. Copyright Agilent

More information

Keysight U9397A/C FET Solid State Switch (SPDT)

Keysight U9397A/C FET Solid State Switch (SPDT) Keysight U9397A/C FET Solid State Switch (SPDT) Operating and Service Manual Notices Copyright Notice Keysight Technologies 2007-2017 No part of this manual may be reproduced in any form or by any means

More information

Quick Start Guide for the PULSE PROFILING APPLICATION

Quick Start Guide for the PULSE PROFILING APPLICATION Quick Start Guide for the PULSE PROFILING APPLICATION MODEL LB480A Revision: Preliminary 02/05/09 1 1. Introduction This document provides information to install and quickly start using your PowerSensor+.

More information

Signal Analysis Measurement Guide

Signal Analysis Measurement Guide Signal Analysis Measurement Guide Agilent Technologies EMC Series Analyzers This guide documents firmware revision A.08.xx This manual provides documentation for the following instruments: E7401A (9 khz-

More information

Keysight N2771B 30 kv High Voltage Probe

Keysight N2771B 30 kv High Voltage Probe Keysight N2771B 30 kv High Voltage Probe User s Guide Notices Keysight Technologies, Inc. 2012-2015 No part of this manual may be reproduced in any form or by any means (including electronic storage and

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Agilent 2-Port and 4-Port PNA-X Network Analyzer N5249A - 10 MHz to 8.5 GHz N5241A - 10 MHz to 13.5 GHz N5242A - 10

More information

Y1160A EIA Rack Sliding Shelf Installation Note

Y1160A EIA Rack Sliding Shelf Installation Note Y1160A EIA Rack Sliding Shelf Installation Note Rack Mount Kit Contents Procedure This installation note contains procedures for mounting L4400 Series LXI instruments in EIA rack cabinets using the Y1160A

More information

Agilent Technologies 8494A/B, 8495A/B, and 8496A/B Attenuators. Operating and Service Manual

Agilent Technologies 8494A/B, 8495A/B, and 8496A/B Attenuators. Operating and Service Manual Agilent Technologies 8494A/B, 8495A/B, and 8496A/B Attenuators Operating and Service Manual Agilent Part Number: 08494-90008 Printed in USA Print Date: April 2002 Supersedes: October 2000 Notice The information

More information

Getting Started Guide

Getting Started Guide MaxEye Digital Audio and Video Signal Generation ISDB-T Signal Generation Toolkit Version 2.0.0 Getting Started Guide Contents 1 Introduction... 3 2 Installed File Location... 3 2.1 Soft Front Panel...

More information

Gain Compression Simulation

Gain Compression Simulation Gain Compression Simulation August 2005 Notice The information contained in this document is subject to change without notice. Agilent Technologies makes no warranty of any kind with regard to this material,

More information

Keysight Technologies Vector Network Analyzer Receiver Dynamic Accuracy

Keysight Technologies Vector Network Analyzer Receiver Dynamic Accuracy Specifications and Uncertainties Keysight Technologies Vector Network Analyzer Receiver Dynamic Accuracy (Linearity Over Its Specified Dynamic Range) Notices Keysight Technologies, Inc. 2011-2016 No part

More information

Signal Generators for Anritsu RF and Microwave Handheld Instruments

Signal Generators for Anritsu RF and Microwave Handheld Instruments Measurement Guide Signal Generators for Anritsu RF and Microwave Handheld Instruments BTS Master Spectrum Master Tracking Generator Option 20 Vector signal Generator Option 23 Anritsu Company 490 Jarvis

More information

E5382B Single-ended Flying Lead Probe Set (for analyzers with 90-pin pod connectors) User Guide

E5382B Single-ended Flying Lead Probe Set (for analyzers with 90-pin pod connectors) User Guide E5382B Single-ended Flying Lead Probe Set (for analyzers with 90-pin pod connectors) User Guide Notices Agilent Technologies, Inc. 2013 No part of this manual may be reproduced in any form or by any means

More information

5008 Dual Synthesizer Configuration Manager User s Guide (admin Version) Version valontechnology.com

5008 Dual Synthesizer Configuration Manager User s Guide (admin Version) Version valontechnology.com 5008 Dual Synthesizer Configuration Manager User s Guide (admin Version) Version 1.6.1 valontechnology.com 5008 Dual Synthesizer Module Configuration Manager Program Version 1.6.1 Page 2 Table of Contents

More information

Operating and Service Manual

Operating and Service Manual Operating and Service Manual Agilent 8490D/G, 8491A/B, 8493A/B/C Coaxial Fixed Attenuators Agilent 11581A, 11582A, 11583C Attenuator Sets Manufacturing Part Number: 08491-90077 Printed in Malaysia Print

More information

TD-SCDMA DesignGuide May 2003

TD-SCDMA DesignGuide May 2003 TD-SCDMA DesignGuide May 2003 Notice The information contained in this document is subject to change without notice. Agilent Technologies makes no warranty of any kind with regard to this material, including,

More information

N2792A and N2793A Differential Probes User s Guide

N2792A and N2793A Differential Probes User s Guide N2792A and N2793A Differential Probes User s Guide Copyright Agilent Technologies 2009 All Rights Reserved. Contents Inspecting the Probe 3 Cleaning the Probe 3 Handling the Probe 3 N2792A and N2793A Differential

More information

Keysight X-Series Signal Analyzers

Keysight X-Series Signal Analyzers Keysight X-Series Signal Analyzers This manual provides documentation for the following Analyzers: PXA Signal Analyzer N9030A EXA Signal Analyzer N9010A MXA Signal Analyzer N9020A Notice: This document

More information

MIDLAND PROGRAMING G14

MIDLAND PROGRAMING G14 MIDLAND PROGRAMING G14 1. PROGRAMMING CAPABILITY Welcome to the MIDLAND Programming software! It s a programming software specifically designed for G14 and must be used in conjunction with the dedicated

More information

Agilent X-Series Signal Analyzer

Agilent X-Series Signal Analyzer Agilent X-Series Signal Analyzer This manual provides documentation for the following X-Series Analyzer: MXA Signal Analyzer N9020A Specifications Guide Agilent Technologies Notices Agilent Technologies,

More information

Agilent X-Series Signal Analyzer

Agilent X-Series Signal Analyzer Agilent X-Series Signal Analyzer This manual provides documentation for the following X-Series Analyzer: EXA Signal Analyzer N9010A Specifications Guide Agilent Technologies Notices Agilent Technologies,

More information

GM8036 Laser Sweep Optical Spectrum Analyzer. Programming Guide

GM8036 Laser Sweep Optical Spectrum Analyzer. Programming Guide GM8036 Laser Sweep Optical Spectrum Analyzer Programming Guide Notices This document contains UC INSTRUMENTS CORP. proprietary information that is protected by copyright. All rights are reserved. This

More information

MBC DG GUI MBC INTERFACE

MBC DG GUI MBC INTERFACE MBC DG GUI MBC INTERFACE User Manual Version 2.6 Table des matières Interface - Introduction... 3 Interface - Setup... 3 Minimum Computer Requirements... 3 Software installation... 3 Hardware Setup...

More information

Measurement Guide and Programming Examples

Measurement Guide and Programming Examples Measurement Guide and Programming Examples N9073A-1FP W-CDMA Measurement Application N9073A-2FP HSDPA/HSUPA Measurement Application For use with the Agilent N9020A MXA and N9010A EXA Signal Analyzers Manufacturing

More information

Agilent G1585A Side Carrier for Manual Inlet Flow Module

Agilent G1585A Side Carrier for Manual Inlet Flow Module Agilent G1585A Side Carrier for Manual Inlet Flow Module 6890 Gas Chromatograph Installation Guide Agilent Technologies Notices Agilent Technologies, Inc. 2002 No part of this manual may be reproduced

More information

BVS RHINO PC INTERFACE SOFTWARE

BVS RHINO PC INTERFACE SOFTWARE BVS RHINO PC INTERFACE SOFTWARE INSTALLATION Copy the file "rhino.exe" from the supplied disk to a directory on the hard drive of the computer. PC SETTINGS PC COM Port 1 must be set as follows using the

More information

Agilent 1146A AC/DC Oscilloscope Current Probe

Agilent 1146A AC/DC Oscilloscope Current Probe A User s Guide Publication number 01146-92003 May 2005 Copyright Agilent Technologies 1996-2005 All Rights Reserved Contents Receiving Your Shipment -2 Packaging -2 Description -3 Compatibility -3 Control

More information

Agilent Technologies 355C, D, E, F VHF Attenuators. Operating and Service Manual

Agilent Technologies 355C, D, E, F VHF Attenuators. Operating and Service Manual Agilent Technologies 355C, D, E, F VHF Attenuators Operating and Service Manual Agilent Part Number: 00355-90051 Printed in USA April 2002 Supersedes: November 2001 Notice The information contained in

More information

Agilent 8494/95/96A/B Attenuators

Agilent 8494/95/96A/B Attenuators Agilent 8494/95/96A/B Attenuators Operating and Service Manual Agilent Technologies Notices Agilent Technologies, Inc. 2011 No part of this manual may be reproduced in any form or by any means (including

More information

Instrument Controllers

Instrument Controllers Instrument Controllers September 2002 Notice The information contained in this document is subject to change without notice. Agilent Technologies makes no warranty of any kind with regard to this material,

More information

Keysight 1147B 50 MHz Current Probe. User s Guide

Keysight 1147B 50 MHz Current Probe. User s Guide Keysight 1147B 50 MHz Current Probe User s Guide Notices Keysight Technologies, Inc. 2000-2016 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval

More information

Introduction to Simulation of Verilog Designs. 1 Introduction. For Quartus II 13.0

Introduction to Simulation of Verilog Designs. 1 Introduction. For Quartus II 13.0 Introduction to Simulation of Verilog Designs For Quartus II 13.0 1 Introduction An effective way of determining the correctness of a logic circuit is to simulate its behavior. This tutorial provides an

More information

TD-SCDMA DesignGuide May 2007

TD-SCDMA DesignGuide May 2007 TD-SCDMA DesignGuide May 2007 Notice The information contained in this document is subject to change without notice. Agilent Technologies makes no warranty of any kind with regard to this material, including,

More information

Getting Started Guide

Getting Started Guide MaxEye ZigBee (IEEE 802.15.4) Measurement Suite Version 1.0.5.3 Getting Started Guide Table of Contents 1. Introduction...3 2. Installed File Location...3 3. Soft Front Panel...5 3.1 MaxEye ZigBee Signal

More information

Ultra-Wideband DesignGuide

Ultra-Wideband DesignGuide Ultra-Wideband DesignGuide January 2007 Notice The information contained in this document is subject to change without notice. Agilent Technologies makes no warranty of any kind with regard to this material,

More information

User s Guide Series USB Power Sensor/Meter. Taking performance to a new peak

User s Guide Series USB Power Sensor/Meter. Taking performance to a new peak User s Guide 52000 Series USB Power Sensor/Meter Taking performance to a new peak Notices BOONTON (A WIRELESS TELECOM GROUP COMPANY) 2006 This document contains information which is protected by copyright.

More information

IQ2015 Connectivity Test System

IQ2015 Connectivity Test System BROCHURE IQ2015 Connectivity Test System TM 2014 LitePoint, A Teradyne Company. All rights reserved. Introduction LitePoint s IQ2015 Connectivity Test System is the first product to specifically address

More information

HP 33120A Function Generator / Arbitrary Waveform Generator

HP 33120A Function Generator / Arbitrary Waveform Generator Note: Unless otherwise indicated, this manual applies to all Serial Numbers. The HP 33120A is a high-performance 15 MHz synthesized function generator with built-in arbitrary waveform capability. Its combination

More information

Keysight 16440A SMU/Pulse Generator Selector

Keysight 16440A SMU/Pulse Generator Selector Keysight 16440A SMU/Pulse Generator Selector User s Guide Notices Keysight Technologies 1994-2014 No part of this manual may be reproduced in any form or by any means (including electronic storage and

More information

Getting Started Guide

Getting Started Guide MaxEye IEEE 0.15.4 UWB Measurement Suite Version 1.0.0 Getting Started Guide 1 Table of Contents 1. Introduction... 3. Installed File Location... 3 3. Programming Examples... 4 3.1. 0.15.4 UWB Signal Generation...

More information

User s Guide. P-Series Power Meters. Compatibility with the 8480 and E-series sensors will be available in a future Firmware release.

User s Guide. P-Series Power Meters. Compatibility with the 8480 and E-series sensors will be available in a future Firmware release. User s Guide P-Series Power Meters Compatibility with the 8480 and E-series sensors will be available in a future Firmware release. N1911A and N1912A Manufacturing Part Number: N1912-90002 Printed in UK

More information

Agilent N6700 Modular Power System Family

Agilent N6700 Modular Power System Family Agilent N67 Modular Power System Family N6731B-N6784A DC Power Modules Specifications Guide Legal Notices Agilent Technologies, Inc. 21-212 No part of this document may be photocopied, reproduced, or translated

More information

User manual Automatic Material Alignment Beta 2

User manual Automatic Material Alignment Beta 2 www.cnccamera.nl User manual Automatic Material Alignment For integration with USB-CNC Beta 2 Table of Contents 1 Introduction... 4 1.1 Purpose... 4 1.2 OPENCV... 5 1.3 Disclaimer... 5 2 Overview... 6

More information

User Manual Solenoid Controller BI-SC1001

User Manual Solenoid Controller BI-SC1001 User Manual Solenoid Controller BI-SC1001 NOTICE Brandstrom Instruments, 2017 85 Ethan Allen Highway Ridgefield, CT 06877 (203) 544-9341 www.brandstrominstruments.com No part of this document may be photocopied,

More information

8472B Crystal Detector. Operating and Service Manual

8472B Crystal Detector. Operating and Service Manual 8472B Crystal Detector Operating and Service Manual Part number: 08472-90022 Printed in USA Print Date: May 2001 Supersedes: April 1999 Notice The information contained in this document is subject to change

More information

MINIMUM SYSTEM REQUIREMENTS

MINIMUM SYSTEM REQUIREMENTS Quick Start Guide Copyright 2000-2012 Frontline Test Equipment, Inc. All rights reserved. You may not reproduce, transmit, or store on magnetic media any part of this publication in any way without prior

More information

Power Meter. Measurement Guide. for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master

Power Meter. Measurement Guide. for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master Measurement Guide Power Meter for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master Power Meter Option 29 High Accuracy Power Meter Option 19 Inline Peak

More information

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors Demo Guide Introduction This demonstration guide helps you to get familiar with the basic setup and configuration

More information

HILINK REAL-TIME HARDWARE-IN-THE-LOOP CONTROL PLATFORM FOR MATLAB/SIMULINK

HILINK REAL-TIME HARDWARE-IN-THE-LOOP CONTROL PLATFORM FOR MATLAB/SIMULINK REAL-TIME HARDWARE-IN-THE-LOOP CONTROL PLATFORM FOR MATLAB/SIMULINK Quick Reference release 1.7 May 1, 2016 Disclaimer The developers of the platform (hardware and software) have used their best efforts

More information

Agilent X-Series Signal Analyzer

Agilent X-Series Signal Analyzer Agilent X-Series Signal Analyzer This manual provides documentation for the following X-Series Instruments: PXA Signal Analyzer N9030A MXA Signal Analyzer N9020A EXA Signal Analyzer N9010A CXA Signal Analyzer

More information

Agilent 2-Port and 4-Port PNA-X Network Analyzer. N5241A - 10 MHz to 13.5 GHz N5242A - 10 MHz to 26.5 GHz Data Sheet and Technical Specifications

Agilent 2-Port and 4-Port PNA-X Network Analyzer. N5241A - 10 MHz to 13.5 GHz N5242A - 10 MHz to 26.5 GHz Data Sheet and Technical Specifications Agilent 2-Port and 4-Port PNA-X Network Analyzer N5241A - 10 MHz to 13.5 GHz N5242A - 10 MHz to 26.5 GHz Data Sheet and Technical Specifications Documentation Warranty THE MATERIAL CONTAINED IN THIS DOCUMENT

More information

Agilent N7620A Signal Studio for Pulse Building

Agilent N7620A Signal Studio for Pulse Building Agilent N7620A Signal Studio for Pulse Building Technical Overview Create a library of complex pulses and pulse patterns by selecting parameters in the software or by importing custom pulses Maximize your

More information

Agilent N2780A, N2781A, N2782A, and N2783A Current Probes

Agilent N2780A, N2781A, N2782A, and N2783A Current Probes Agilent N2780A, N2781A, N2782A, and N2783A Current Probes User s and Service Guide Agilent Technologies Notices Agilent Technologies, Inc. 2007 No part of this manual may be reproduced in any form or by

More information

Introduction to Simulation of Verilog Designs Using ModelSim Graphical Waveform Editor. 1 Introduction. For Quartus II 13.1

Introduction to Simulation of Verilog Designs Using ModelSim Graphical Waveform Editor. 1 Introduction. For Quartus II 13.1 Introduction to Simulation of Verilog Designs Using ModelSim Graphical Waveform Editor For Quartus II 13.1 1 Introduction This tutorial provides an introduction to simulation of logic circuits using the

More information

ArbStudio Arbitrary Waveform Generators

ArbStudio Arbitrary Waveform Generators ArbStudio Arbitrary Waveform Generators Key Features Outstanding performance with 16-bit, 1 GS/s sample rate and 2 Mpts/Ch 2 and 4 channel models Digital pattern generator PWM mode Sweep and burst modes

More information

Introduction to Simulation of Verilog Designs. 1 Introduction. For Quartus II 11.1

Introduction to Simulation of Verilog Designs. 1 Introduction. For Quartus II 11.1 Introduction to Simulation of Verilog Designs For Quartus II 11.1 1 Introduction An effective way of determining the correctness of a logic circuit is to simulate its behavior. This tutorial provides an

More information

ArbStudio Arbitrary Waveform Generators. Powerful, Versatile Waveform Creation

ArbStudio Arbitrary Waveform Generators. Powerful, Versatile Waveform Creation ArbStudio Arbitrary Waveform Generators Powerful, Versatile Waveform Creation UNMATCHED WAVEFORM UNMATCHED WAVEFORM GENERATION GENERATION Key Features 125 MHz bandwidth 1 GS/s maximum sample rate Long

More information

Keysight X-Series Signal Analyzers

Keysight X-Series Signal Analyzers Keysight X-Series Signal Analyzers This manual provides documentation for the following Analyzers: PXA Signal Analyzer N9030A MXA Signal Analyzer N9020A EXA Signal Analyzer N9010A CXA Signal Analyzer N9000A

More information

Keysight U7243B USB3.1 Electrical Compliance Test Application. Methods of Implementation

Keysight U7243B USB3.1 Electrical Compliance Test Application. Methods of Implementation Keysight U7243B USB3.1 Electrical Compliance Test Application Methods of Implementation Notices Keysight Technologies 2017 No part of this manual may be reproduced in any form or by any means (including

More information

LD2342 USWM V1.6. LD2342 V1.4 Page 1 of 18

LD2342 USWM V1.6. LD2342 V1.4 Page 1 of 18 LD2342 USWM V1.6 LD2342 V1.4 Page 1 of 18 GENERAL WARNINGS All Class A and Class B marine Automatic Identification System (AIS) units utilize a satellite based system such as the Global Positioning Satellite

More information

Agilent N2893A 100 MHz Current Probe

Agilent N2893A 100 MHz Current Probe Agilent N2893A 100 MHz Current Probe User s Guide Publication number N2893-97000 January 2011 For Safety information, Regulatory information, and publishing information, see the pages at the end of this

More information

RIGOL. Quick Guide. DG2000 Series Function/Arbitrary Waveform Generator. Sept RIGOL Technologies, Inc.

RIGOL. Quick Guide. DG2000 Series Function/Arbitrary Waveform Generator. Sept RIGOL Technologies, Inc. Quick Guide DG2000 Series Function/Arbitrary Waveform Generator Sept. 2010 RIGOL Technologies, Inc. Guaranty and Declaration Copyright 2010 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information

More information

PC Tune PC Tune Test Procedures for 5100 Series Portable Radios

PC Tune PC Tune Test Procedures for 5100 Series Portable Radios PC Tune PC Tune Test Procedures for 5100 Series Portable Radios Part Number 002-9998-6513014 August 2008 Copyright 2006, 2007, 2008 by EFJohnson Technologies The EFJohnson Technologies logo, PC Configure,

More information

Agilent W2100 Antenna Modeling Design System

Agilent W2100 Antenna Modeling Design System Agilent W2100 Antenna Modeling Design System User s Guide Agilent Technologies Notices Agilent Technologies, Inc. 2007-2008 No part of this manual may be reproduced in any form or by any means (including

More information

N9051A Pulse Measurement Software

N9051A Pulse Measurement Software N9051A Pulse Measurement Software X-Series Signal Analyzers and PSA Series Spectrum Analyzers Technical Overview Characterize pulse performance using a wide range of parameters including pulse width, rise/fall

More information

Agilent N6700 Modular Power System Family

Agilent N6700 Modular Power System Family Agilent N67 Modular Power System Family N6731B-N6784A DC Power Modules Specifications Guide Legal Notices Agilent Technologies, Inc. 21, 211 No part of this document may be photocopied, reproduced, or

More information

F-Intermod User Guide Telecom Engineering Inc r61

F-Intermod User Guide Telecom Engineering Inc r61 1 of 14 9-Sep-13 6:41 PM F-Intermod User Guide Telecom Engineering Inc. 2012 r61 Please visit our website at http://www.telecomengineering.com/software-download1.htm to check for any updates. Introduction

More information

Keysight U7250A MIPI C-PHY SM Compliance Test Application. Methods of Implementation

Keysight U7250A MIPI C-PHY SM Compliance Test Application. Methods of Implementation Keysight U7250A MIPI C-PHY SM Compliance Test Application Methods of Implementation Notices Keysight Technologies 2017 No part of this manual may be reproduced in any form or by any means (including electronic

More information

Introduction to Simulink Assignment Companion Document

Introduction to Simulink Assignment Companion Document Introduction to Simulink Assignment Companion Document Implementing a DSB-SC AM Modulator in Simulink The purpose of this exercise is to explore SIMULINK by implementing a DSB-SC AM modulator. DSB-SC AM

More information

RFDE Broadband SPICE Model Generator

RFDE Broadband SPICE Model Generator RFDE Broadband SPICE Model Generator Notices Agilent Technologies, Inc. 1983-2007 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation

More information

Agilent U7239A WiMedia Wrapper Automated Test Application. Online Help

Agilent U7239A WiMedia Wrapper Automated Test Application. Online Help Agilent U7239A WiMedia Wrapper Automated Test Application Online Help A Notices Agilent Technologies, Inc. 2006-2009 No part of this manual may be reproduced in any form or by any means (including electronic

More information