Real time spectrum analyser sound level meters

Size: px
Start display at page:

Download "Real time spectrum analyser sound level meters"

Transcription

1

2 Real time spectrum analyser sound level meters SC310 Class 1 analyser (1/1 + 1/3 + FFT) The SC310 analyser is the definitive solution for professionals in acoustics who need a precision, high performance, user-friendly instrument: One instrument, many solutions. Measurement of sound insulation in one-third octave bands (ISO 140). Measurement of environmental parameters: tonal, impulsive and low frequency components (ISO 1996). Evaluation of industrial noise: functions every 125 ms and FFT analysis. Real time reverberation time measurements in octave and one-third octave bands (ISO 3382). Analysis of vibration in buildings (ISO ) and FFT analysis. Class 1 integrating SLM in accordance with IEC and ANSI. Real time spectrum analyser, one-third octave bands 10 Hz to 20 khz (EF Module) and octave bands 31.5 Hz to 16 khz. Simultaneous measurement of 84 parameters with a single measurement range: 23 to 140 db peak and with frequency weightings A, C and Z. Incorporates a circular memory (64 MB): data download while measuring. Multi-connectivity with PC: USB, Bluetooth, modem and serial. Removable preamplifier for use with extension cables and outdoor kit. Capture Studio Software included: data download, real time communication, graphic and numerical display of registers and report generation. Extension modules for the SC310 RT Module: Module for real time reverberation time measurements in octave and one-third octave bands (ISO 3382). EF Module: Module for extended frequency analysis: Simultaneous measurement of one-third octave bands from 10 to 20 khz, overall values (A, C and Z) and advanced parameters: tonality, impulsivity and low frequency. Includes FFT analysis of 430 lines from 0 to 20 khz for sound. VM Module: Module for measurements of human exposure to whole body vibration in buildings (ISO ). Includes FFT analysis of 430 lines from 0 to 1 khz for vibrations. DS Module: Dosimeter module for evaluation of the exposure of workers to noise at work, and simultaneous testing of the efficiency of hearing protectors (PPE) using the SNR, HML and Octave methods.

3 SC-30 Class 1 Analyser (1/1) High precision analyser, indispensable in any engineering office, for carrying out quick and easy acoustic measurements. Building acoustics: Measurement of sound insulation in octave bands (quality control), acoustic comfort and evaluation of rooms (NC/NR curves). Simultaneous evaluation of the exposure of workers to noise at work and testing of personal protective equipment: minimum metrological uncertainty (Directive 2003/10/CE). Class 1 integrating sound level meter in accordance with IEC and ANSI. Real time spectrum analyser in octave bands 31,5 Hz to 16 khz. Simultaneous measurement of 54 parameters with a single measurement range: 23 to 140 db peak, and with A, C and Z frequency weightings. Capture Studio Software included: data download, real time communication, graphic and numerical display of registers and generation of reports. SC160 Class 2 Analyser (1/1) Low cost, user-friendly analyser with frequency analysis in octave bands. Sound insulation testing in octave bands. Simultaneous evaluation of workers exposure to noise at work and testing of personal protective equipment (Directive 2003/10/CE). Testing of noise levels of industrial machinery and air conditioning systems (HVAC). Room acoustics: real time evaluation of NC and NR curves, sound reinforcement of halls and equalization of professional audio equipment. Class 2 integrating sound level meter in accordance with IEC and ANSI. Real time spectrum analyser in octave bands 31.5 Hz to 16 khz. Simultaneous measurement of 54 parameters with single measurement range: 30 to 140 db peak and with A, C and Z frequency weightings. Capture Studio Software included: data download, real time communication, graphic and numerical display of registers. Extension modules for SC-30 y SC160 RT Module: Module for real time reverberation time measurements in octave bands. DS Module: Dosimeter module for the evaluation of workers exposure to noise at work and the simultaneous testing of the efficiency of hearing protectors (PPE) using the SNR, HML and Octave methods.

4 Sound level meters and integrating sound level meters SC-20e Class 1 Integrating SLM SC-20c Class 1 Integrating SLM SC-15c Class 2 Integrating SLM High performance sound level meter for precision measurements: environmental noise, vehicle noise and sound power. Technical Inspection of vehicles: measurement of vehicle noise. Environmental acoustics: acoustic maps and outdoor measurements. Measurement of sound power of machinery (CE mark approval). Class 1 integrating sound level meter in accordance with IEC and ANSI. Simultaneous measurement with a single measurement range: 23 to 140 db peak and with A or C frequency weighting. Removable preamplifier for use with extension cables and outdoor kit. Memory for registering the time history of the measurement. Programmable Leq acquisition time. Real time PC communication software, data download, reports, data display and calculations of Leq and measurement interval percentiles. The perfect instrument for precision measurements and subsequent report generation (local bylaws). Testing according to local bylaws. Measurement of noisy activities: neighbourhood and traffic. Class 1 integrating sound level meter in accordance with IEC and ANSI. Simultaneous measurement with a single measurement range: 23 to 140 db peak and with A or C frequency weighting. Memory to register the time history of the measurement. Real time communication software with PC, data download, reports, data display and calculation of Leq and percentiles of measurement intervals. Economical, user-friendly sound level meter with memory and PC communication. Inspection of noisy activities: neighbourhood and vehicles. Hearing protection for workers without PPE. Class 2 integrating SLM in accordance with IEC and ANSI. Simultaneous measurement with single measurement range: 30 to 140 db peak and with A or C frequency weighting. Memory to register the time history of the measurement. Extension cable. Real time communication software with PC, data download, reports and data display.

5 SC-3 Class 1 SLM Ideal instrument for carrying out measurements, quickly and easily, with engineering precision. Evaluation of machine, activity and neighbourhood noise. Vehicle and traffic noise. Class 1 sound level meter in accordance with IEC and ANSI. Simultaneous measurement of L AS and L AF functions and their maximum values. Single measurement range: dba with A frequency weighting. Removable preamplifier for use with extension cables. SC-2c Class 2 SLM Its low cost and user-friendliness make it the optimum instrument for tasks of vehicle and neighbourhood noise inspection. Professional audiovisual system installations. Evaluation of activity and vehicle noise. Class 2 sound level meter in accordance with IEC and ANSI. Measures all parameters at the same time: L AS,L AF and maximums. Has a single scale: dba with A frequency weighting. Real time dosimeter spectrum analyser DC112 Dosimeter Analyser (1/1) The DC112 is a high performance dosimeter analyser in octave bands, ideal for the measurement of noise in accordance with Directive 2003/10/CE on the protection of workers from exposure to noise. Simultaneous evaluation of workers exposure to noise at work and testing of PPE (Personal Protective Equipment). Dosimeter compliant with norm EN 61252, and DIRECTIVE 2003/10/CE. Real time frequency analysis in octave bands for the evaluation of PPE (Personal Protective Equipment). Saves the time history of the measurement in the memory (64 MB). Projection of parameters: evaluation of exposure to noise for measurement times shorter than the exposure time. Powered by batteries (16 h) and through the USB. Capture Studio Software included: data download (USB port), real time communication, graphic and numerical display.

6 Sound calibrators CB-5 Sound calibrator Portable instrument, for easy handling and maximum precision in the testing of sound level meters and dosimeters on the measuring site. Class 1L sound calibrator in accordance with IEC and EN for the testing of class 1 and class 2 instruments. Testing frequency: 1 khz. Two sound pressure levels: 94 db and 104 db. Vibration measuring equipment CV111 Vibration calibrator Quick and easy testing of vibrometers and accelerometers. Testing on the measuring site (rechargeable internal battery). Precision, user-friendly instrument. Testing in units of acceleration (La = 140 db or a = 10 m/s 2 ), speed (10 mm/s) or displacement (10 µm). Testing frequency: ω = 1000 rad/s (f = Hz). Accepts accelerometers up to 520 g. AC001 and AC006 Accelerometers AC001 Measurement of human exposure to whole body vibrations in buildings (ISO ). Testing, analysis and measurement of vibration produced by machinery in general. DA050 AC001: ICP compatible accelerometer. Sensitivity: 100 mv/g. Frequency margin (± 10%): 0.3 Hz to 14 khz. Accelerometer for generic applications: testing, analysis and measurement of machine vibration in industrial environments. AC006: ICP compatible accelerometer. Sensitivity: 1000 mv/g. Frequency margin (± 10%): 0.2 Hz to 2600 Hz. Accelerometer for the measurement of human exposure to whole body vibrations in buildings (ISO ). DA050: Bag of 40 pure wax discs to affix accelerometers. AC006

7 Equipment for environmental measurements TK-1000 Outdoor Kit The TK-1000 outdoor kit is the perfect solution for measurements from a few days to several months in outdoor environments. It includes protection from meteorological inclemency: dehumidifier, rain, wind and bird protector for preamplifier and microphone. The use of the TK-1000 does not modify the typology of CESVA sound level meters. Extension cables CN: Extension cables of various lengths (3, 10 and 30 m) for sound level meters SC310, SC-30, SC-20e and SC-3. CNR-ITV: 10 m Extension cable for sound level meters SC160, SC-15c and SC-2c. Power sources Power feeders for all types of network: 230 V / 50 Hz or 110 V / 60 Hz. Battery converters adaptable to each sound level meter: from 12 V to 5 V or from 12 V to 9 V. GSM / GPRS Communications System The mobile communications system for CESVA equipment is based on the GSM / GPRS standard and facilitates communication between various CESVA instruments (sound level meters and limiters) and a personal computer. Remote downloading of data from devices to PC and real time communication. Comfortable capture of data from monitoring stations (dynamic acoustic maps) or from sound control systems of musical and leisure activities (acoustic limiters). CSE Software for editing and recalculating measurements CSE (Capture Studio Editor) is a software application which makes it possible to edit the data acquired by CESVA dosimeters and spectrum analysers SC310, SC-30, SC160 and DC112. It is an intuitive, user-friendly tool with which any section of the measurement can be extracted or eliminated, and overall and spectral values of the chosen section can be recalculated, as well as statistical information, (maximums, minimums and percentiles).

8 Equipment for the measurement of sound insulation GIP Solution for the measurement of insulation GIP (Global Insulation Package) is the definitive solution for quick, reliable and economical measurement (ISO 140), calculation and creation of sound insulation reports (ISO 717). The GIP solution consists of centralising the measurement in a laptop computer (using CMA software) which, using wireless (Bluetooth ) technology controls, in real time, both the sound source (FP120 and MI005) and the analysers (SC310). All the elements of GIP are independent and integral to the solution. The solution is extendable in number of analysers and sound sources to form a synchronised multi-channel system. Once the measurement process is finished, all the data is included in the insulation project. This project is opened by CIS, which instantaneously creates the normalised insulation report. MI005 Tapping machine Tapping machine for measuring the sound insulation of floors for impact noise (standardised for ISO and ISO 140-7). Robust, light and user-friendly, remotely (by cable or Bluetooth wireless) or manually controlled. Consists of 5 hammers with electronic impact control. Transport box included. Complies with annex A of ISO and FP120 Sound pressure source The FP120 sound pressure source is a set which comprises the AP600 noise generator and the BP012 omnidirectional dodecahedral loudspeaker. *Does not include tripod ISO 140: Measurement of sound insulation in buildings and of building elements. ISO 3382: Measurement of the reverberation time of rooms. ISO 354: Measurement of sound absorption in a reverberant room. Omnidirectional radiation diagram. Complies with ISO db Sound power. Unbeatable response at low frequency. Generation of white, pink and filtered pink (one-third octave bands from 50 to 5 khz) noise. Wireless control.

9 CMA Software for carrying out insulation measurements CMA (CESVA Measuring Assistant) is the latest generation of software for managing all the resources which take place in insulation measurements of airborne and impact noise and of façades. The programme guides, step by step, and gives the user complete support in real time, before, during and after the measurement, optimising speed and ease of use: BEFORE: Import of plans, selection of measurement points and checking the positioning of devices. DURING: Automatic management of devices using Bluetooth, step by step guide to the measurement, indicating the position of the devices, starting and stopping the sound sources and receiving and checking the results in real time. AFTER: Interacts directly with CIS to receive the final report on the measurement site. With this software application a number of CESVA analysers can be converted into a multi-channel wireless measuring system. The system is completely extendible simply by adding more devices (analysers or sound sources). CIS Software for the calculation and generation of insulation reports CIS (CESVA Insulation Studio) is powerful software for carrying out calculations and generating sound insulation reports: airborne noise insulation between rooms and of façades, impact noise insulation and reverberation time (ISO 140, ISO 717 and ISO 3382). The application is also designed for laboratory and field trials (ISO to ISO140-8) and national and international norms. CIS can be updated for any modification of these norms. The programme automatically creates the report quickly and easily from data downloaded from the CESVA analysers SC160, SC-30 and SC310 and also accepts manual data input. It allows the editing of decay curves for the calculation of reverberation time by various methods. The data from the analysers can be represented and edited in graph and numerical format. These representations can be exported to other applications via the clipboard. CIS will print the report directly, and save it as a PDF file or as an image. Bluetooth wireless communication system Combination of Bluetooth wireless, multi-channel and bidirectional communication comprising a number of devices: one connected to the PC and others connected to the instruments which form the system. Wireless system for measuring insulation of airborne noise, façades or impact noise. Signal transmission through concrete walls. Multi-point environmental measurements, multi-channel measurements and dynamic acoustic maps. Simultaneous bidirectional communication between PC and analysers, sound pressure sources and tapping machines.

10 Laboratory instruments FC-822 Front-end The FC-822 is an eight-channel front-end with independent inputs. It is indispensable for multi-channel, precision acoustic measurements, both in the laboratory and in the field. It has an internal battery to enable it to work without connection to an electricity supply. Each of its 8 channels powers and conditions the signal from a microphone (polarised to 200 V) or an ICP accelerometer, regulates the gain in 10 db steps and inserts high pass and low pass filters. Each channel has an independent overload indicator. C-130 and C-250 Microphones C-130: Condenser microphone polarised to 200 V C-250: Prepolarised microphone. PA-13, PA-14, PA-25 and PA-05 Preamplifiers PA-25 PA-05 PA-13: Preamplifier for 200 V polarised microphone (C-130). PA-14: Preamplifier for prepolarised microphone (C-250). PA-25: ICP preamplifier for prepolarised microphone (C-250). PA-05: ICP preamplifier for microphone P-05. PA-13 and PA-14 Accessories CAPTURE STUDIO Software for download and display of measurements Powerful free software for CESVA analysers and dosimeters (SC310, SC-30, SC160 and DC112) which: Configures the analyser and the dosimeter. Downloads data from the memory of the devices. Communicates in real time. Displays data graphically and numerically. Converts data to different formats. Copies graphs and tables to the clipboard for the generation of reports.

11 Accessories ML-50 and ML-10 Carrying cases Carrying cases for sound level meter sets: ML-50: 49 x 36 x 14 cm ML-10: 38 x 30 x 8 cm ML-50 ML-10 Tripods and Rods PR003 Tripod for SLMs, dosimeters and microphones (for use with TR001): TR-40: from 20 cm to 1,2 m TR050: from 20 cm to 1,5 m Tripod for BP012 omnidirectional sound source. TR012:Tripod up to 2 m TR014:Tripod with wheels, up to 2 m Rod for façade measurements. PR003: 3 m rod TR050 TR014 Data transmission cables Cables for the transmission of data to PC (USB, serial and serial-usb) and cables for audio output (AC output) for different SLM models. IM003 Printer Serial printer of 40 columns RS-serial input battery and feeder.

12 Company founded in 1969 in Barcelona, specialising in research, development, manufacture and marketing of instruments for measuring and controlling noise and vibrations. All our products are designed and manufactured in our factory with our own patents. Agile and efficient distribution network which enables CESVA products to be present around the world. After sales service. Prompt repair service. Customer care, by telephone or , attending to any questions about the handling or usage of our instruments within 24 hours. Training in the use and operational set up of our equipment; a service which we at CESVA consider indispensable for our customers to be able to get the most from our equipment. Training for groups, professional associations, official state bodies, etc. Website where you will find all the information you need: Technical specifications and software downloads. Quotes without any obligation. Contact us, and stay up to date with all the training activities and exhibitions which we have regularly. ISO 9001:2000 certified for activities of design, manufacture, distribution and sale of equipment for the measurement and control of noise. Villar, 20, bajos BARCELONA (SPAIN) Tel. (+34) Fax (+34) info@cesva.com For further information CESVA INSTRUMENTS, S. L. reserves the right to alter the characteristics of these technical specifications and accessories without prior notice. CI200706ENG

Progress driven by research

Progress driven by research 2 CESVA Serving acoustics for over 40 years The company was founded in 1969 in Barcelona. It specialises in the research, development, manufacture and sale of instruments for the measurement and control

More information

SC310. Integrating sound level meter real time spectrum analyser* in one third octave and octave bands

SC310. Integrating sound level meter real time spectrum analyser* in one third octave and octave bands Integrating sound level meter real time spectrum analyser* in one third octave and octave bands D_SC310_v0034_20111212_ENG Applications Acoustic insulation in one third octave bands* Environmental noise

More information

SC160. Integrating Sound Level Meter Real time frequency Analyser* in Octave Band

SC160. Integrating Sound Level Meter Real time frequency Analyser* in Octave Band D_SC160_v0041_20111212_ENG Applications Evaluation of the noise exposure of workers at workplace simultaneously to the verification of PPE (Personal Protective Equipment) Room acoustics: NC and NR evaluation,

More information

SC260. Integrating sound level meter real time spectrum analyser* in one third octave and octave bands

SC260. Integrating sound level meter real time spectrum analyser* in one third octave and octave bands Integrating sound level meter real time spectrum analyser* in one third octave and octave bands D_SC260_v0003_20111212_ENG Applications Acoustic insulation in one third octave bands* Environmental noise

More information

SC101. Class 1 integrating sound level meter with measurement. Applications Includes measurement protocols for: Noise generated by motor vehicles

SC101. Class 1 integrating sound level meter with measurement. Applications Includes measurement protocols for: Noise generated by motor vehicles Class 1 integrating sound level meter with measurement protocols Applications Includes measurement protocols for: MEASURING NOISE HAS NEVER BEEN SO EASY Noise generated by motor vehicles D_SC101_v0015_20120703_ENG

More information

SC420. Class 1 sound level meter and spectrum analyser * by third octave bands DATASHEET

SC420. Class 1 sound level meter and spectrum analyser * by third octave bands DATASHEET DATASHEET D_SC420_v0006_20140219_ENG Class 1 sound level meter and spectrum analyser * by third octave bands PRESENTATION the SC420 is an instrument distinguished for its power, versatility, ergonomics

More information

NoiseMeters. The Practical & Easy To Use Solution for Industrial & Environmental Noise Measurements.

NoiseMeters. The Practical & Easy To Use Solution for Industrial & Environmental Noise Measurements. NoiseMeters The Practical & Easy To Use Solution for Industrial & Environmental Noise Measurements. Simple to use solutions for occupational, general & environmental noise measurements Meets the latest

More information

SC420. Sound Level Meter Spectrum Analyser USER MANUAL. M_SC420_v0014_ _ENG

SC420. Sound Level Meter Spectrum Analyser USER MANUAL. M_SC420_v0014_ _ENG SC420 Sound Level Meter Spectrum Analyser USER MANUAL M_SC420_v0014_20150522_ENG Since its beginnings in Barcelona in 1969, has been devoted to manufacturing sound equipment and instrumentation through

More information

Airborne Sound Insulation

Airborne Sound Insulation Airborne Sound Insulation with XL2-TA Sound Level Meter This application note describes the verification of the airborne sound insulation in buildings with the XL2-TA Sound Level Meter. All measurements

More information

NoiseMeters. Integrating Sound Level Meters Effective Solutions For Industrial Noise Management

NoiseMeters. Integrating Sound Level Meters Effective Solutions For Industrial Noise Management Integrating Sound Level Meters Effective Solutions For Industrial Noise Management The most simple to use, cost effective, compliant instruments of their kind Ideal for quick, accurate measurements to

More information

Measuring Instrument Combinations

Measuring Instrument Combinations PISTONPHONE START/STOP GRP NUM SLM RTA CAL LIGHT STORE MENU 1 FREQ WEIGHT TIME PUSH ON OFF ENT MODE 2 PAUSE/CONT 4 LEVEL 3 POWER PISTONPHONE Measuring Instrument Combinations 1 2 Acoustic Measurement Calibration

More information

THE ANV MEASUREMENT SYSTEMS SOUND INSULATION TESTING SYSTEM INSTRUCTION MANUAL FOR FIELD TESTING OF WALLS, FLOORS & STAIRS

THE ANV MEASUREMENT SYSTEMS SOUND INSULATION TESTING SYSTEM INSTRUCTION MANUAL FOR FIELD TESTING OF WALLS, FLOORS & STAIRS THE ANV MEASUREMENT SYSTEMS SOUND INSULATION TESTING SYSTEM INSTRUCTION MANUAL FOR FIELD TESTING OF WALLS, FLOORS & STAIRS HASTINGS HOUSE, AUCKLAND PARK, MILTON KEYNES, MK1 1BU 01908 642846 01908 642814

More information

CEL63x Sound Level Meter CEL630, CEL631, CEL632, CEL633 Class 1 or Class 2. Integrating. Advanced Logging. Audio Recording

CEL63x Sound Level Meter CEL630, CEL631, CEL632, CEL633 Class 1 or Class 2. Integrating. Advanced Logging. Audio Recording CEL63x Sound Level Meter CEL630, CEL631, CEL632, CEL633 Class 1 or Class 2. Integrating. Advanced Logging. Audio Recording Environmental Noise Boundary noise assessments Noise nuisance complaints Measurements

More information

Product and Measurement Solutions for the Automotive Industry

Product and Measurement Solutions for the Automotive Industry Product and Measurement Solutions for the Automotive Industry Car body and vehicle related measurement solutions P.4-5 Acceleration noise measurement Acceleration Noise Measurement System Measurement of

More information

Acoustic Calibration Service in Automobile Field at NIM, China

Acoustic Calibration Service in Automobile Field at NIM, China Acoustic Calibration Service in Automobile Field at NIM, China ZHONG Bo National Institute of Metrology, China zhongbo@nim.ac.cn Contents 1 Overview of Calibration Services 2 Anechoic Room Calibration

More information

CR:800C Sound Level Meters

CR:800C Sound Level Meters Cirrus Research plc dedicated to noise measurement CR:800C Sound Level Meters CR:800C Key Features Ideal for both Occupational and Environmental noise measurements Complies with the latest IEC 61672 standard

More information

Environmental Sound Monitor NA-37 E n v i r o n m e n t a l S o u n d M o n i t o r (For Environmental Measurement) NA-37

Environmental Sound Monitor NA-37 E n v i r o n m e n t a l S o u n d M o n i t o r (For Environmental Measurement) NA-37 Easily Monitor Road Traffic Noise, Factory Noise, Construction Noise It complies with the manual of the Evaluation of Environmental Quality Standards for Noise. Environmental Sound Monitor The is capable

More information

NA-28. Top of the Rion Range of Sound Level Meters. Sound level meter and 1/3 octave band real-time analyzer

NA-28. Top of the Rion Range of Sound Level Meters. Sound level meter and 1/3 octave band real-time analyzer NA-28 Top of the Rion Range of Sound Level Meters Sound level meter and 1/3 octave band real-time analyzer Easy to use compact design with comprehensive features Rion s priorities for on-site measurements

More information

REPORT ON THE ON-SITE ACOUSTIC MEASUREMENTS CARRIED OUT TO CALCULATE THE ACOUSTIC INSULATION OF THE WEWORK+ CABIN

REPORT ON THE ON-SITE ACOUSTIC MEASUREMENTS CARRIED OUT TO CALCULATE THE ACOUSTIC INSULATION OF THE WEWORK+ CABIN REPORT ON THE ON-SITE ACOUSTIC MEASUREMENTS CARRIED OUT TO APLING, SLU - Comm. Reg. of Barcelona: Tome 32162. Sheet 0188. General Sect. Entry. 1ª Page 209026 C.I.F. B-60413499 CALCULATE THE ACOUSTIC INSULATION

More information

Measuring procedures for the environmental parameters: Acoustic comfort

Measuring procedures for the environmental parameters: Acoustic comfort Measuring procedures for the environmental parameters: Acoustic comfort Abstract Measuring procedures for selected environmental parameters related to acoustic comfort are shown here. All protocols are

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Electric and Magnetic Field Measurement For Isotropic Measurement of Magnetic and Electric Fields Evaluation of Field

More information

2260 INVESTIGATOR MODULAR PRECISION SOUND ANALYZER WITH APPLICATION SOFTWARE BZ 7210, BZ 7203, BZ 7204, BZ 7205, BZ 7206, BZ 7207, BZ 7208

2260 INVESTIGATOR MODULAR PRECISION SOUND ANALYZER WITH APPLICATION SOFTWARE BZ 7210, BZ 7203, BZ 7204, BZ 7205, BZ 7206, BZ 7207, BZ 7208 BF0213-11_Original_26-35.qxd 16-12-2003 08:52 Page 30 2260 INVESTIGATOR MODULAR PRECISION SOUND ANALYZER WITH APPLICATION SOFTWARE BZ 7210, BZ 7203, BZ 7204, BZ 7205, BZ 7206, BZ 7207, BZ 7208 Where Do

More information

Selective and broadband low frequency field analysis

Selective and broadband low frequency field analysis ELECTRIC AND MAGNETIC FIELD ANALYZER EHP-50C Selective and broadband low frequency field analysis Electric and magnetic low frequency field analysis up to 100 khz Isotropic measurement with a dynamic range

More information

For Isotropic Measurement of Magnetic and Electric Fields

For Isotropic Measurement of Magnetic and Electric Fields Field Analyzers EFA-300 For Isotropic Measurement of Magnetic and Electric Fields Evaluation of Field Exposure compared to Major Standards and Guidance (selectable) Shaped Time Domain (STD) an innovative

More information

CR:247 Invictus. Portable Noise Monitor. Features. Features. Applications

CR:247 Invictus. Portable Noise Monitor. Features. Features. Applications Key Features High performance portable noise monitor Purpose designed for outdoor noise measurement applications Simultaneous measurement of all parameters 120dB measurement range in a single span Colour

More information

CHAPTER 3 THE DESIGN OF TRANSMISSION LOSS SUITE AND EXPERIMENTAL DETAILS

CHAPTER 3 THE DESIGN OF TRANSMISSION LOSS SUITE AND EXPERIMENTAL DETAILS 35 CHAPTER 3 THE DESIGN OF TRANSMISSION LOSS SUITE AND EXPERIMENTAL DETAILS 3.1 INTRODUCTION This chapter deals with the details of the design and construction of transmission loss suite, measurement details

More information

WinMLS I very much like the convenience of the tool and how quickly measurements can be made - Christopher Pye, Integral Acoustics, Canada

WinMLS I very much like the convenience of the tool and how quickly measurements can be made - Christopher Pye, Integral Acoustics, Canada WinMLS 2004 What is WinMLS? WinMLS is a sound card based software for high quality audio, acoustics and vibrational measurements using your PC/laptop. The fact that it is sound card based, makes it possible

More information

English. Operating manual. Integrating Sound Level Meter Spectrum Analyzer HD2010UC/A. Keep for future reference.

English. Operating manual. Integrating Sound Level Meter Spectrum Analyzer HD2010UC/A.  Keep for future reference. English Operating manual Integrating Sound Level Meter Spectrum Analyzer HD2010UC/A Companies / Brands of GHM www.deltaohm.com Keep for future reference. 1 2 3 27 4 26 5 6 7 25 24 23 8 9 10 11 12 13 22

More information

Noise Excitation Equipment for Building Acoustics Measurements Loudspeaker Systems Nor275 and Nor276 Power Amplifier Nor280 Tapping Machine Nor277

Noise Excitation Equipment for Building Acoustics Measurements Loudspeaker Systems Nor275 and Nor276 Power Amplifier Nor280 Tapping Machine Nor277 Product Data Noise Excitation Equipment for Building Acoustics Measurements Loudspeaker Systems Nor275 and Nor276 Power Amplifier Nor280 Tapping Machine Nor277 Norsonic is a leading supplier of noise excitation

More information

NEW! XL2 EXELLINE HANDHELD AUDIO AND ACOUSTIC ANALYZER LESS NOISE. MORE SOUND. Sound Level Meter. Real Time Analyzer. FFT Analyzer.

NEW! XL2 EXELLINE HANDHELD AUDIO AND ACOUSTIC ANALYZER LESS NOISE. MORE SOUND. Sound Level Meter. Real Time Analyzer. FFT Analyzer. LESS NOISE. MORE SOUND NEW! Sound Level Meter Real Time Analyzer FFT Analyzer STI-PA Analyzer XL2 HANDHELD AUDIO AND ACOUSTIC ANALYZER Audio Analyzer EXELLINE Made in Switzerland www.nti-audio.com Introduction

More information

ODEON APPLICATION NOTE ISO Open plan offices Part 2 Measurements

ODEON APPLICATION NOTE ISO Open plan offices Part 2 Measurements ODEON APPLICATION NOTE ISO 3382-3 Open plan offices Part 2 Measurements JHR, May 2014 Scope This is a guide how to measure the room acoustical parameters specially developed for open plan offices according

More information

SW Series Impedance Tube Solutions

SW Series Impedance Tube Solutions SW Series Impedance Tube Solutions BSWA SW series Impedance Tubes can accurately measure sound absorption coefficients and impedance according to ISO or ASTM standards. They also support the sound transmission

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 1996-2 Second edition 2007-03-15 Acoustics Description, measurement and assessment of environmental noise Part 2: Determination of environmental noise levels Acoustique Description,

More information

C1.1 Specification of the SVAN 971 as SLM in the standard configuration

C1.1 Specification of the SVAN 971 as SLM in the standard configuration SVAN 971 USER MANUAL. C TECHNICAL SPECIFICATIONS C.1 Specification of SVAN 971 as sound level meter The following appendix effects for firmware version 1.11.1 or greater. C1.1 Specification of the SVAN

More information

CLIO Pocket is Audiomatica's new Electro-Acoustical Multi-Platform Personal measurement system.

CLIO Pocket is Audiomatica's new Electro-Acoustical Multi-Platform Personal measurement system. Release 1.5! CLIO Pocket is Audiomatica's new Electro-Acoustical Multi-Platform Personal measurement system. The system comes complete of the CLIO Pocket software (Windows and OSX native), the CLIO CP-01

More information

Nor150 Sound Intensity Option Sound intensity probe Nor1290

Nor150 Sound Intensity Option Sound intensity probe Nor1290 Product Data Nor150 Sound Intensity Option Sound intensity probe Nor1290 Sound Power measurements in accordance with - ISO 9614 - ANSI S12.12 - ECMA 160 Noise Mapping Noise Source locations Innovative

More information

PD002. Product Data ZIRCON. Loudspeaker-Microphone Probe

PD002. Product Data ZIRCON. Loudspeaker-Microphone Probe PD002 Product Data ZIRCON Loudspeaker-Microphone Probe Copyright 2003-2006 Acoustics Engineering January 2006 This page intentionally left blank. Description The Zircon is a loudspeaker-microphone probe

More information

NEW! XL2 EXELLINE HANDHELD AUDIO AND ACOUSTIC ANALYZER LESS NOISE. MORE SOUND. Sound Level Meter. Real Time Analyzer. FFT Analyzer.

NEW! XL2 EXELLINE HANDHELD AUDIO AND ACOUSTIC ANALYZER LESS NOISE. MORE SOUND. Sound Level Meter. Real Time Analyzer. FFT Analyzer. LESS NOISE. MORE SOUND NEW! Sound Level Meter Real Time Analyzer FFT Analyzer STI-PA Analyzer XL2 HANDHELD AUDIO AND ACOUSTIC ANALYZER Audio Analyzer EXELLINE Made in Switzerland www.nti-audio.com Introduction

More information

Impulse response. Frequency response

Impulse response. Frequency response CLIOwin 7, by Audiomatica, is the new measurement software for the CLIO System. The CLIO System is the easiest and less expensive way to measure: - electrical networks - electronic equipment - loudspeaker

More information

BSWA Impedance Tube Solutions

BSWA Impedance Tube Solutions BSWA Impedance Tube Solutions Version: 20008 BSWA Company Introduction Established in 998, BSWA Technology Co., Ltd. is becoming the preferred supplier for acoustical measurements. With headquarter located

More information

A Guide to Environmental Noise Measurement Terminology

A Guide to Environmental Noise Measurement Terminology A Guide to Environmental Noise Measurement inology A summary of parameters and functions shown by the Optimus Sound Level Meters and Trojan Noise Nuisance Recorder A FREE ebook from The Noise Experts Environmental

More information

Organisation Internationale de Métrologie Légale

Organisation Internationale de Métrologie Légale Organisation Internationale de Métrologie Légale INTERNATIONAL RECOMMENDATION Sound level meters Sonomètres OIML R 58 Edition 1998 (E) CONTENTS Foreword... 3 1 Scope... 4 2 Construction and maximum permissible

More information

CONTRIBUTION REGARDING NOISE MEASUREMENT ACOUSTIC PROCEDURES ON BOARD

CONTRIBUTION REGARDING NOISE MEASUREMENT ACOUSTIC PROCEDURES ON BOARD SISOM 2013, Acoustics and Robotics, Bucharest 21-22 May CONTRIBUTION REGARDING NOISE MEASUREMENT ACOUSTIC PROCEDURES ON BOARD Victor POPOVICI 1, Claudia BORDA 1, Delicia ARSENE 1, Larisa BUTU 1, Marinela

More information

PRODUCT DATA. DIRAC Room Acoustics Software Type Photo courtesy of Muziekcentrum Frits Philips, Eindhoven, The Netherlands

PRODUCT DATA. DIRAC Room Acoustics Software Type Photo courtesy of Muziekcentrum Frits Philips, Eindhoven, The Netherlands PRODUCT DATA DIRAC Room Acoustics Software Type 7841 MEASURING ROOM ACOUSTICS Brüel & Kjær is the sole worldwide distributor of DIRAC, an acoustics measurement software tool developed by Acoustics Engineering.

More information

PRODUCT DATA. Noise Monitoring Terminals Types 3597 C, 3637 A/B and 3631

PRODUCT DATA. Noise Monitoring Terminals Types 3597 C, 3637 A/B and 3631 PRODUCT DATA Noise Monitoring Terminals Types 3597 C, 3637 A/B and 3631 Brüel & Kjær Noise Monitoring Terminal (NMT) Type 3597 is for external use, in all climatic environments, and is a component of an

More information

Universal multi-channel acoustic measuring system

Universal multi-channel acoustic measuring system TM Universal multi-channel acoustic measuring system Sound level measurement Frequency analysis Sound recording Human vibration measurement Pass-by noise measurement Building acoustics Machine vibration

More information

Think environment Think Casella

Think environment Think Casella NOISE NOTES SECTION PAGE CONTENTS 01. Background and history 02 02. Our commitment 03 03. Applications satisfied by the Casella CEL products 04 04. Products by family grouping Simple sound level meters

More information

Fundamentals of Environmental Noise Monitoring CENAC

Fundamentals of Environmental Noise Monitoring CENAC Fundamentals of Environmental Noise Monitoring CENAC Dr. Colin Novak Akoustik Engineering Limited April 03, 2013 Akoustik Engineering Limited Akoustik Engineering Limited is the sales and technical representative

More information

TECHNICAL NOTES. Sound Level Meter NA Higashimotomachi, Kokubunji, Tokyo , Japan

TECHNICAL NOTES. Sound Level Meter NA Higashimotomachi, Kokubunji, Tokyo , Japan TECHNICAL NOTES Sound Level Meter NA-28 3-20-41 Higashimotomachi, Kokubunji, Tokyo 185-8533, Japan http://www.rion.co.jp/english/ Organization of the NA-28 Documentation The documentation for the Sound

More information

Errata to Procedural Standard for Sound & Vibration Measurement 2015 Third Edition

Errata to Procedural Standard for Sound & Vibration Measurement 2015 Third Edition Errata to Procedural Standard for Sound & Vibration Measurement 2015 Third Edition Correction Sheet #1 Issued 01 July 2018 Copyright 2018 by NEBB All rights reserved. Published 2018. Printed in the United

More information

CORRECTION NOTICE SOUTH AFRICAN CIVIL AVIATION AUTHORITY CIVIL AVIATION ACT, 2009 (ACT NO. 13 OF 2009)

CORRECTION NOTICE SOUTH AFRICAN CIVIL AVIATION AUTHORITY CIVIL AVIATION ACT, 2009 (ACT NO. 13 OF 2009) CORRECTION NOTICE SOUTH AFRICAN CIVIL AVIATION AUTHORITY CIVIL AVIATION ACT, 2009 (ACT NO. 13 OF 2009) The Director of Civil Aviation has, in terms of section 163(1) of the Civil Aviation Act, 2009 (Act

More information

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011 EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011 All-in-one Digital EMI Analyzer 10 Hz - 3 GHz PMM 9010/30P EMI Analyzer 10 Hz - 3 GHz Our trek started in a small laboratory over 25

More information

PRODUCT DATA. Noise Monitoring Terminal Plus Type 3639-E Noise Monitoring Terminal Advanced Type 3639-G. Uses and Features

PRODUCT DATA. Noise Monitoring Terminal Plus Type 3639-E Noise Monitoring Terminal Advanced Type 3639-G. Uses and Features PRODUCT DATA Noise Monitoring Terminal Plus Type 3639-E Type 3639-G Noise Monitoring Terminals Type 3639 are a range of powerful, modular, noise monitoring terminals, optimised for outdoor use. With a

More information

Transfer Function (TRF)

Transfer Function (TRF) (TRF) Module of the KLIPPEL R&D SYSTEM S7 FEATURES Combines linear and nonlinear measurements Provides impulse response and energy-time curve (ETC) Measures linear transfer function and harmonic distortions

More information

Microphone Cartridge Model: MP201

Microphone Cartridge Model: MP201 BSWA MICROPHONES Established in 1998, BSWA Technology Co., Ltd is becoming a preferred microphone supplier in China and the world. With the high quality and low price strategy, many OEMs and system integrators

More information

The Nor121 Analyser. - for any Environmental or Building Acoustic measurement

The Nor121 Analyser. - for any Environmental or Building Acoustic measurement Product Data The Nor121 Analyser - for any Environmental or Building Acoustic measurement Alightweight, rugged and hand-held analyser with 80 or 120dB dynamic range, single or dual channel capability,

More information

HEAD. Advanced Filters Module (Code 5019) Overview. Features. Module with various filter tools for sound design

HEAD. Advanced Filters Module (Code 5019) Overview. Features. Module with various filter tools for sound design HEAD Ebertstraße 30a 52134 Herzogenrath Tel.: +49 2407 577-0 Fax: +49 2407 577-99 email: info@head-acoustics.de Web: www.head-acoustics.de ASM 19 Data Datenblatt Sheet Advanced Filters Module (Code 5019)

More information

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009 EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009 Our trek started in a small laboratory over 25 years ago. Since then, we ve been focused on making EMC measurements easier and the measuring

More information

Nor150 Sound Intensity Option Sound intensity probe Nor1290

Nor150 Sound Intensity Option Sound intensity probe Nor1290 Product Data Nor150 Sound Intensity Option Sound intensity probe Nor1290 Sound Power measurements in accordance with - ISO 9614 - ANSI S12.12 - ECMA 160 Noise Mapping Noise Source locations Innovative

More information

Condition-based maintenance of power transformers Complete three-phase system Turns Ratio: Recovery Voltage: Winding Resistance:

Condition-based maintenance of power transformers Complete three-phase system Turns Ratio: Recovery Voltage: Winding Resistance: ETP SYSTEM Condition-based maintenance of power transformers The predictive and condition based maintenance is nowadays accepted as the most efficient solution to guarantee the proper operation of critical

More information

USER MANUAL SVAN 971 POCKET-SIZE SOUND LEVEL METER & ANALYSER. Copyright 2018 SVANTEK. All rights reserved.

USER MANUAL SVAN 971 POCKET-SIZE SOUND LEVEL METER & ANALYSER. Copyright 2018 SVANTEK. All rights reserved. USER MANUAL SVAN 971 POCKET-SIZE SOUND LEVEL METER & ANALYSER Warsaw, 28-03-2018 Copyright 2018 SVANTEK. All rights reserved. SVAN 971 User 2 Note: On account of continuous product improvement SVANTEK

More information

Main Features. Highlights

Main Features. Highlights Highlights For portable use or continuos system; Multi-position measuring system using wireless communication from MASTER to SLAVE units; N.4 analog inputs, n.1 digital inputs; Inputs extension using MASTER/SLAVE

More information

Analysis of static and time-variable magnetic fields

Analysis of static and time-variable magnetic fields Magnetometer HP-01 Analysis of static and time-variable magnetic fields Field exposure evaluation according to current standards and regulations such as Directive 2013/35/EU for workplaces Frequency-selective

More information

Testing to IEC

Testing to IEC APPENDIX B Testing to IEC61672-1 This appendix presents information for measuring the sound level meter functionality of the LxT according to IEC61672-1. Sections 5, 6, 7 and 9 (except 9.3) The following

More information

nor140 SOUND ANALYSER

nor140 SOUND ANALYSER nor140 SOUND ANALYSER Applications: Environmental noise Sound recording Building acoustics Noise source identification Industrial hygiene Product development Quality control Sound power Speech intelligibility

More information

The ArtemiS multi-channel analysis software

The ArtemiS multi-channel analysis software DATA SHEET ArtemiS basic software (Code 5000_5001) Multi-channel analysis software for acoustic and vibration analysis The ArtemiS basic software is included in the purchased parts package of ASM 00 (Code

More information

PRODUCT DATA. Uses and Features

PRODUCT DATA. Uses and Features PRODUCT DATA Sound Sources for Building Acoustics: OmniPower Sound Source Type 4292, OmniSource Sound Source Type 4295, Tapping Machine Type 3207, and Power Amplifiers Type 2734-A and 2734-B For proper

More information

R-Log Radio data logger

R-Log Radio data logger > data loggers R-Log Radio data logger Highlights For portable use or continuos system; Multi-position measuring system using wireless communication from MASTER to SLAVE units; N.4 analog inputs, n.1 digital

More information

CEL 200 Series Simple Sound Level Meters

CEL 200 Series Simple Sound Level Meters CEL 200 Series Simple Sound Level Meters Casella USA is proud to announce the CEL-200 Series of sound level meters. These FAQ s help to give an overview of the current models, answer some of the more typical

More information

Revision of ISO Standards on field sound insulation testing. Carl Hopkins

Revision of ISO Standards on field sound insulation testing. Carl Hopkins Revision of ISO Standards on field sound insulation testing Carl Hopkins COST FP0702 & TU0901 meeting, EMPA, November 2011 Why revise the field testing Standards? Editorial reasons Introduction of the

More information

A Guide to Noise Measurement Terminology

A Guide to Noise Measurement Terminology A Guide to Noise Measurement inology A summary of parameters and functions shown by the Optimus Sound Level Meters, Trojan Noise Nuisance Recorder and dosebadge Noise Dosimeter A FREE ebook from The Noise

More information

BSWA SW420R Impedance Tube System

BSWA SW420R Impedance Tube System BSWA SW420R Impedance Tube System - For Pavements Absorption Testing - ISO3472-2 Version: 20406 BSWA Company Introduction Established in 998, BSWA Technology Co., Ltd. is becoming the preferred supplier

More information

Where Safety Matters, Use The Latest Technology

Where Safety Matters, Use The Latest Technology Electromagnetic Safety Equipment Where Safety Matters, Use The Latest Technology 146 Electromagnetic radiation is becoming more of a safety concern to individuals as well as workers. Dedicated RF safety

More information

Safety Evaluation Within a Magnetic Field Environment

Safety Evaluation Within a Magnetic Field Environment EXPOSURE LEVEL TESTER ELT-400 Safety Evaluation Within a Magnetic Field Environment Direct evaluation of field exposure in comparison with major standards Automatic exposure evaluation for various waveforms

More information

PRODUCT DATA USES. BENEFITS Normal incidence parameters are determined Fast and accurate measurements. Type 4206A. Type Type 4206T 50 Hz 1.

PRODUCT DATA USES. BENEFITS Normal incidence parameters are determined Fast and accurate measurements. Type 4206A. Type Type 4206T 50 Hz 1. PRODUCT DATA Impedance Tube Kit (50 Hz 6.4 khz) Type 4206 Impedance Tube Kit (100 Hz 3.2 khz) Type 4206 A Transmission Loss Tube Kit (50 Hz 6.4 khz) Type 4206 T Brüel & Kjær offers a complete range of

More information

MAGNETIC FIELD METER Operator s Manual

MAGNETIC FIELD METER Operator s Manual Edition 3.1 2009-09-03 MAGNETIC FIELD METER 2000 Operator s Manual The MFM 2000 is a professional magnetic field instrument To make the best use of the instrument we recommend that you read this manual

More information

Measurement of Airborne Sound Insulation (Separating Walls) At Gwynne Gardens, East Grinstead

Measurement of Airborne Sound Insulation (Separating Walls) At Gwynne Gardens, East Grinstead H+H UK Limited Technical Services Department Celcon House Ightham, Sevenoaks Kent, TN15 9HZ +44 (0)1732 880580 Telephone +44 (0)1732 880581 Fax Measurement of Airborne Sound Insulation (Separating Walls)

More information

CEL 630 Series Full Color Real Time Analyzers

CEL 630 Series Full Color Real Time Analyzers CEL 630 Series Full Color Real Time Analyzers Frequently Asked Questions Casella USA announces the introduction of four new models to the CEL range of noise measurement equipment. The multi-function CEL-630,

More information

Reverberation time and structure loss factor

Reverberation time and structure loss factor Reverberation time and structure loss factor CHRISTER HEED SD2165 Stockholm October 2008 Marcus Wallenberg Laboratoriet för Ljud- och Vibrationsforskning Reverberation time and structure loss factor Christer

More information

Continuous, remote monitoring and logging of electromagnetic fields

Continuous, remote monitoring and logging of electromagnetic fields NARDA EMF MONITORS AMB-8059 Continuous, remote monitoring and logging of electromagnetic fields Interchangeable probes from 10 Hz to 40 GHz for low frequency & high frequency applications Multi-band probes

More information

Fractional Octave Analysis and Acoustic Applications

Fractional Octave Analysis and Acoustic Applications www.mpihome.com m+p Analyzer Fractional Octave Analysis and Acoustic Applications Noise is increasingly the subject of new regulations for the protection of human health and safety as well as for improving

More information

VIBRATION ANALYZER. Vibration Analyzer VA-12

VIBRATION ANALYZER. Vibration Analyzer VA-12 VIBRATION ANALYZER Vibration Analyzer VA-12 Portable vibration analyzer for Equipment Diagnosis and On-site Measurements Vibration Meter VA-12 With FFT analysis function Piezoelectric Accelerometer PV-57with

More information

YRS01 York Reference Source

YRS01 York Reference Source York Reference Source York Reference Source The YRS01 is a multi-mode reference source capable of producing a broadband noise or comb output up to 1GHz. Selectable noise or comb output - Flexibility across

More information

Tap Changer Analyzer & Winding Ohmmeter RMO-TT

Tap Changer Analyzer & Winding Ohmmeter RMO-TT Tap Changer Analyzer & Winding Ohmmeter RMO-TT On-load tap changer dynamic resistance measurement Three resistance measurement channels Four temperature measurement channels Vibration measurement Automatic

More information

CLIO 10, by Audiomatica, is the new measurement software for the CLIO System. The CLIO System is the easiest and less expensive way to measure:

CLIO 10, by Audiomatica, is the new measurement software for the CLIO System. The CLIO System is the easiest and less expensive way to measure: CLIO 10, by Audiomatica, is the new measurement software for the CLIO System. The CLIO System is the easiest and less expensive way to measure: electrical networks electronic equipment loudspeaker systems

More information

Precision Integrating Sound Level Meter

Precision Integrating Sound Level Meter Precision Integrating Sound Level Meter Type 2236 A 009 Type 2236 B 009 Type 2236 C 009 Type 2236 D 009 With software version 2.1 or higher Revision November 1996 Brüel & Kjær BB0909 13 Trademarks IBM

More information

VIBRATION ANALYZER. Vibration Analyzer VA-12

VIBRATION ANALYZER. Vibration Analyzer VA-12 VIBRATION ANALYZER Vibration Analyzer VA-12 Portable vibration analyzer for Equipment Diagnosis and On-site Measurements Vibration Meter VA-12 With FFT analysis function Piezoelectric Accelerometer PV-57with

More information

Technical Documentation

Technical Documentation Technical Documentation Microphone Type 4964 for Hand-held Analyzer Types 2250, 2250-L and 2270 Supplement to Instruction Manual BE 1712 English BE 1864 11 Microphone Type 4964 for Hand-held Analyzer

More information

Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3

Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3 Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3 GHz Magnetic fields monitoring from 10 Hz to 5 khz Automatic

More information

TPS 49 EDITION 2 JUNE 2009

TPS 49 EDITION 2 JUNE 2009 TPS 49 EDITION 2 JUNE 2009 Interim arrangements & guidance on the interpretation of IEC 61672 Sound Level Meters - Periodic Tests CONTENTS SECTION PAGE 1 Purpose and duration 2 2 Statement 2 3 Specific

More information

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease Fluke 1740 Series Three-Phase Power Quality Loggers Memobox Technical Data Assess power quality and conduct long-term studies with ease Compact and rugged, the Fluke 1740 Series three-phase power quality

More information

PIPELINE DEFECT MAPPER

PIPELINE DEFECT MAPPER PIPELINE DEFECT MAPPER Receiver Colour Display C.A.T. Survey Graph ACVG Survey Graph GIS View General: The Pipeline Defect Mapper Kit designed and developed in such a way; to precisely locate and assist

More information

PRODUCT DATA. Sound Intensity Probe Kit Type 3599 including Sound Intensity Microphone Pair Type 4197 and Dual Preamplifier Type 2683

PRODUCT DATA. Sound Intensity Probe Kit Type 3599 including Sound Intensity Microphone Pair Type 4197 and Dual Preamplifier Type 2683 PRODUCT DATA Sound Intensity Probe Kit Type 3599 including Sound Intensity Microphone Pair Type 4197 and Dual Preamplifier Type 2683 Type 3599 is a two-microphone probe kit for measuring sound intensity.

More information

Exposure Level Tester ELT-400

Exposure Level Tester ELT-400 Safety Evaluation within a Magnetic Field Environment Exposure Level Tester ELT-400 Direct Evaluation of Field Exposure Compared to Major Standards (IEEE C95.6) Automatic Exposure Evaluation for Various

More information

PRODUCT DATA. Sound Intensity Probe Kit Type 3599 Sound Intensity Microphone Pair Type 4197 Dual Preamplifier Type 2683

PRODUCT DATA. Sound Intensity Probe Kit Type 3599 Sound Intensity Microphone Pair Type 4197 Dual Preamplifier Type 2683 PRODUCT DATA Probe Kit Type 3599 Microphone Pair Type 4197 Dual Preamplifier Type 2683 Type 3599 is a two-microphone probe kit for measuring sound intensity. Specially designed for use with Brüel & Kjær

More information

Dodecahedron Speaker Set

Dodecahedron Speaker Set Dodecahedron Speaker Set Omnidirectional Sound Source Comprised of the DS3 Dodecahedron Loudspeaker and the PA3 Power Amplifier, the set generates a Pink noise signal with an acoustically-flat frequency

More information

PRODUCT DATA. Noise Monitoring Terminal Plus Type 3639-E Noise Monitoring Terminal Advanced Type 3639-G

PRODUCT DATA. Noise Monitoring Terminal Plus Type 3639-E Noise Monitoring Terminal Advanced Type 3639-G PRODUCT DATA Noise Monitoring Terminal Plus Type 3639-E Type 3639-G Noise Monitoring Terminals Type 3639 are a range of powerful, modular, noise monitoring terminals, optimised for outdoor use. With a

More information

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease Fluke 1740 Series Three-Phase Power Quality Loggers Memobox Technical Data Assess power quality and conduct long-term studies with ease Compact and rugged, the Fluke 1740 Series three-phase power quality

More information

Selective and broadband high frequency field analysis

Selective and broadband high frequency field analysis ELECTRIC AND MAGNETIC FIELD ANALYZER EHP-200A Selective and broadband high frequency field analysis New solution for isotropic measurements in the 9 khz 30 MHz range Electric Fields from 0.02 to 1000 V/m

More information

PRODUCT DATA. Sound Intensity Calibrator Type Uses and Features

PRODUCT DATA. Sound Intensity Calibrator Type Uses and Features PRODUCT DATA Sound Intensity Calibrator Type 4297 Sound Intensity Calibrator Type 4297 is used for on site sound pressure calibration and pressure residual intensity index verification. Its most important

More information