DIGITAL MIXER D-901. (Version 3) INSTRUCTION MANUAL

Size: px
Start display at page:

Download "DIGITAL MIXER D-901. (Version 3) INSTRUCTION MANUAL"

Transcription

1 INSTRUTI MANUAL DIGITAL MIXER D-90 (Version 3) Thank you for purchasing TOA's Digital Mixer. Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment. Traceability Information for Europe (EM directive 004/08/E) Manufacturer: TOA orporation 7--, Minatojima Nakamachi, huo-ku, Kobe, Hyogo, Japan Authorized representative: TOA Electronics Europe GmbH Suederstrasse 8, 0537 Hamburg, Germany

2 TABLE OF TENTS. SAFETY PREAUTIS GENERAL DESRIPTI FEATURES HANDLING PREAUTIS NOMENLATURE AND FUNTIS 5.. D-90 Digital Mixer Front... 8 Rear Optional Modules 5... D-9F Microphone/Line Input Module D-9E Microphone/Line Input Module D-9F Microphone/Line Input Module D-9E Microphone/Line Input Module D-936R Stereo Input Module D-93AE Digital Input Module D-937SP Digital Input Module D-97M Line Output Module D-97E Line Output Module D-97R Line Output Module D-97AE Digital Output Module D-96SP Digital Output Module D-98 Remote ontrol Module D-983 Remote ontrol Module D-984V VA ontrol Module SETTING BASIS 6.. Setting Procedures Setting Flowcharts 6... Input and output settings Microphone bus settings Preset memory settings Utility settings Setting Keys and Knob Setting Screen Displays INPUT/OUTPUT GAIN SETTINGS 7.. Input and Output hannel ontrol Section Settings Input/Output Gain Setting Screen Operation Input/Output hannel Gain Setting Screen Operation INPUT-RELATED SETTINGS 8.. Phantom Power /OFF Settings (Only with D-9E or D-9F module) PAD (Input Sensitivity) Settings (Only with D-9E or D-9F module) Line Input Mode Selection (Only with D-936R module) hannel Status Verification (Only with D-93AE or D-937SP module) Input signal status verification Sampling frequency verification Pre-emphasis verification Line (Stereo) Input Selection (Only with D-936R or D-937SP module) Input Trim Settings Input trim gain settings... 8

3 8.6.. Input trim polarity settings High-Pass Filter Settings utoff frequency settings Q settings Equalizer Settings Gain settings enter frequency settings Q settings ompressor/auto-leveler Mode Selection ompressor Settings (only when the compressor mode is selected in Section 8.9.) Threshold level settings Ratio settings Attack time settings Release time settings Makeup gain settings Auto-Leveler Settings (only when the auto-leveler mode is selected in Section 8.9.) 8... Target level settings Maximum gain settings Attack time settings Release time settings Level Sense Settings 8... Attack time settings Release time settings Gate Settings Threshold level settings Hysteresis settings Depth settings Hold time settings Attack time settings Release time settings Auto-Mixing Group Settings Ducker Settings Priority settings Attenuation settings Attack time settings Release time settings NOM Attenuation /OFF Settings Input hannel Gain Settings Input hannel Group Trim Gain Settings (Only when Group is set) Bus Assignment and rosspoint Gain Settings Bus assignment settings rosspoint gain settings OUTPUT SETTINGS 9.. Output hannel Gain Settings Output hannel Group Trim Gain Settings (Only when Group is set) rossover Settings (Only when rossover function is enabled) Slope settings utoff frequency settings Q settings Q settings rossover gain settings rossover filter polarity settings Filter Settings

4 9.4.. Parametric equalizer High-pass filter Low-pass filter High shelving filter Low shelving filter Horn equalizer Notch filter All-pass filter ompressor Settings Threshold level settings Ratio settings Attack time settings Release time settings Makeup gain settings Delay Time Settings MIROPHE BUS SETTINGS 0.. Feedback Suppression Settings 0... Dynamic mode settings Auto mode activation Filter number settings Dynamic mode filter initialization Auto mode filter initialization Feedback Suppression Filter Setting onfirmation 0... Mode confirmation Frequency confirmation Filter gain confirmation Q confirmation Effect (Echo) Settings Echo gain settings Feedback ratio settings Feedback delay settings Initial echo (pre-) delay settings Low-pass filter frequency settings Low-pass filter Q settings Bus Assignment and rosspoint Gain Settings (Microphone Bus Output hannel) Bus assignment settings rosspoint gain settings PRESET MEMORY SETTINGS.. Preset Memory Save Preset Memory Recall Preset Memory Delete Preset Memory rossfade Time Settings Initial Preset Memory Selection onfiguration Save UTILITY SETTINGS.. Stereo Link Settings Group Settings rossover onfiguration Settings NOM Attenuation Settings ontact Input/Output Settings (Available only when D-98, D-983 or D-984V is used).5.. Function assignment to the input contact... 65

5 .5.. Function assignment to the output contact Protect Settings RS-3 Port Settings.7.. ontrol mode selection RS-3 transmission rate settings All Input/Output hannel Gain onfirmation All Input/Output VA Status onfirmation (Only when the D-984V is used) Module Type onfirmation.0.. Individual slots confirmation All slots confirmation ooling Fan Operating Status onfirmation Firmware Version onfirmation RESTORING FATORY DEFAULT SETTINGS FIRMWARE UPDATE RAK MOUNTING NETIS 6.. onnection Example onnection Example (Broadcasting to two separate zones) Removable Terminal Plug onnection Ferrite able lamp Attachment (For D-97AE only) onnections of the D-984V onnecting to the D-984V Input and output channel VA controls ontact controls BLOK DIAGRAM LEVEL DIAGRAMS 8.. Analog Input/Output Digital Input/Output SETTING ITEMS AND SETTING RANGES SPEIFIATIS 0.. D-90 Digital Mixer D-9F Microphone/Line Input Module (Optional) D-9E Microphone/Line Input Module (Optional) D-9F Microphone/Line Input Module (Optional) D-9E Microphone/Line Input Module (Optional) D-936R Stereo Input Module (Optional) D-93AE Digital Input Module (Optional) D-937SP Digital Input Module (Optional) D-97M Line Output Module (Optional) D-97E Line Output Module (Optional) D-97R Line Output Module (Optional) D-97AE Digital Output Module (Optional) D-96SP Digital Output Module (Optional) D-98 Remote ontrol Module (Optional) D-983 Remote ontrol Module (Optional) D-984V VA ontrol Module (Optional)

6 . SAFETY PREAUTIS Be sure to read the instructions in this section carefully before use. Make sure to observe the instructions in this manual as the conventions of safety symbols and messages regarded as very important precautions are included. We also recommend you keep this instruction manual handy for future reference. Safety Symbol and Message onventions Safety symbols and messages described below are used in this manual to prevent bodily injury and property damage which could result from mishandling. Before operating your product, read this manual first and understand the safety symbols and messages so you are thoroughly aware of the potential safety hazards. WARNING AUTI Indicates a potentially hazardous situation which, if mishandled, could result in death or serious personal injury. Indicates a potentially hazardous situation which, if mishandled, could result in moderate or minor personal injury, and/or property damage. 6 When Installing the Unit Do not expose the unit to rain or an environment where it may be splashed by water or other liquids, as doing so may result in fire or electric shock. Use the unit only with the voltage specified on the unit. Using a voltage higher than that which is specified may result in fire or electric shock. Do not cut, kink, otherwise damage nor modify the power supply cord. In addition, avoid using the power cord in close proximity to heaters, and never place heavy objects -- including the unit itself -- on the power cord, as doing so may result in fire or electric shock. When the Unit is in Use WARNING Should the following irregularity be found during use, immediately switch off the power, disconnect the power supply plug from the A outlet and contact your nearest TOA dealer. Make no further attempt to operate the unit in this condition as this may cause fire or electric shock. If you detect smoke or a strange smell coming from the unit. If water or any metallic object gets into the unit If the unit falls, or the unit case breaks If the power supply cord is damaged (exposure of the core, disconnection, etc.) If it is malfunctioning (no tone sounds.) To prevent a fire or electric shock, never open nor remove the unit case as there are high voltage components inside the unit. Refer all servicing to your nearest TOA dealer. Do not place cups, bowls, or other containers of liquid or metallic objects on top of the unit. If they accidentally spill into the unit, this may cause a fire or electric shock. When Installing the Unit Never plug in nor remove the power supply plug with wet hands, as doing so may cause electric shock. When unplugging the power supply cord, be sure to grasp the power supply plug; never pull on the cord itself. Operating the unit with a damaged power supply cord may cause a fire or electric shock. Do not block the fan exhaust vent on the unit's rear and the ventilation slots on the bottom. Doing so may cause heat to build up inside the unit and result in fire. Avoid installing the unit in humid or dusty locations, in locations exposed to the direct sunlight, near the heaters, or in locations generating sooty smoke or steam as doing otherwise may result in fire or electric shock. When installing the unit in an equipment rack, observe the following instructions. Failure to do so may result in fire or personal injury. Install the rack on a solid and stable surface. Then, secure it with anchor bolts or make other appropriate arrangements to prevent it from falling down or moving. Use the screws supplied with the unit to mount on TOA's rack. The A outlet to which the unit's A power cable is connected must have allowable current capacity over the unit's current consumption. When the Unit is in Use AUTI Switch off the power, and unplug the power supply plug from the A outlet for safety purposes when cleaning or leaving the unit unused for 0 days or more. Doing otherwise may cause a fire or electric shock.

7 . GENERAL DESRIPTI TOA's D-90 is a 9-inch rack-mounted (3U high) digital mixer configured with inputs, 8 buses, and 8 outputs. It features signal processing functions necessary for sound systems such as feedback suppression and auto-mixing. All functional parameters can be set at the unit*. Settings can be stored in the unit's internal memory as "preset memory" and can be recalled using the front panel-mounted operation keys. * an also be set at a P using the setting software, which can be downloaded from our website " 3. FEATURES Acoustic feedback can be suppressed through simple operation. Auto-Mixing functions (Ducker* and NOM Attenuation* ) automatically adjust the input signal volume. Signals are digitally processed, ensuring high-accuracy sound parameter settings. All settings can be performed at the unit using the LD screen and setting keys and knobs located on the front panel. The settings can also be made at a P using the dedicated software. Modular construction permits flexible configuration of inputs and outputs, from -IN/4-OUT to -IN/8-OUT systems. Up to 6 preset patterns can be stored in memory, which can be easily recalled from either the unit or connected external equipment. An RS-3 port permits remote control of the unit using an AMX or restron controller, or similar external equipment. The control protocol is available for download at our website A protect function prevents accidental changes of front panel key settings. The use of an optional D-98 or D-983 Remote ontrol Module, or an optional D-984V VA ontrol Module permits easy remote operation of volume control and preset memory recall. The use of an optional D-984V VA ontrol Module permits the sound volume to be adjusted from remote locations using the faders or volume controls. * Automatically adjusts all channel gains in response to input signal level. (Refer to p. 38.) * Automatically adjusts the input gain of open microphones corresponding to the number of open microphones in the system. (Refer to p. 39.) Notes AMX is a trademark of AMX orporation. restron is a trademark of restron Electronics, Inc. 4. HANDLING PREAUTIS Warning: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Note: This equipment has been tested and found to comply with the limits for a lass A digital device, pursuant to part 5 of the F Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Use the unit in locations where the temperature is between +5 to +40 (no condensation) and the humidity is less than 90%. The D-90 is a precision audio component. To prevent failure, avoid locations where the unit may be exposed to strong shocks or vibrations. Do not place combustible material under the unit. To clean, be sure to first switch off the power, then wipe with a dry cloth. When extremely dirty, use a soft cloth dampened in neutral detergent. Never use benzene, thinner or chemically-treated towels, which may damage the unit's finish. 7

8 5. NOMENLATURE AND FUNTIS 5.. D-90 Digital Mixer [Front] Parameter input section Input channel control section (described below) (Refer to p. 9.) Output channel control section (Refer to p. 0.) DIGITAL MIXER model D-90 7 PEAK 8 +db +6dB UTILITY dB -6dB 3 4 PRESET LOK 5 6 SEL SIG 0N 0N SIG SEL SEL -db -0dB -40dB POWER OFF ENTRY SETI 5 FBS 0N SIG SEL 8 6 EFFET PRESET INPUT MI BUS OUTPUT Preset memory selection section Microphone bus control section (Refer to p. 9.) (Refer to p. 0.). Power switch [POWER, / OFF] The unit's power switches when this switch is pressed, and switches OFF when pressed again.. Power Indicator Lights when the power is switched. Parameter Input Section p. 68.) Flashes when the D-90 is communicating with a P. UTILITY PRESET LOK 7. Setting Knob [, PUSH- ENTER] This knob can be rotated to change parameters or select setting contents, and also operates as a push switch. Pressing the knob when the [OK?] indication is displayed on the LD screen (5) enables the corresponding function Utility Indicator Remains lit during selection of the utility function. 4. Utility Key [UTILITY] Selects the utility function. Pressing this key displays the utility function setting screen on the LD screen (5). (Refer to p. 6.) 5. LD Screen When the function key is pressed, its corresponding setting screen is displayed on this screen. If the unit's internal cooling fan malfunctions, the "ERROR indication appears on the screen even during setting operation. In this case, contact your TOA dealer. 6. System Lock Indicator [LOK] Lights when the protect function is enabled. (For more information on the protect function, refer to 8. Preset Indicator Remains lit during preset memory selection. 9. Preset Key [PRESET] Recalls the settings stored in preset memory or saves the current parameters. The preset memory setting screen appears on the LD (5) when this key is pressed. (Refer to p. 59.) 0. Screen Shift Keys [ ] Pressing these keys change the setting items on the LD (5).. Function /OFF Indicator Lights when the parameter shown on the LD (5) is enabled ().. Function /OFF Key [] Parameters displayed on the LD (5) are enabled () when this key is pressed, and disabled (OFF) when pressed again.

9 Preset Memory Selection Section Preset Memory Selector Keys [ 8] Recall preset memory patterns 8. To recall, press the desired Preset Memory Selector key, then press the Setting knob (7). 4. Preset Memory Indicators The LED corresponding to the currently selected Preset Memory Selection key is illuminated. 4 8 PRESET 4 Input hannel ontrol Section 5 7 Green: Signal level is between 40 db and +7 db on the basis of the rated input signal level. OFF: Signal level is lower than 40 db below the rated input signal level SEL SIG 0N 0N SIG SEL LED Red Green Input signal level +7 db Rated input signal level 40 db OFF INPUT Input hannel Selector Keys [ ] Used to select the input channel for sound volume adjustment or parameter setting. The Input channel indicator [SEL] (6) lights when a key is pressed, causing the corresponding channel number to be displayed on the setting screen. 6. Input hannel Indicators [SEL, SIG, ] SEL: Lights when the input channel is selected. SIG Indicates the input signal level in two colors (red and green). The status of indicator shows as follows depending on the input signal levels. Red: Signal level is 7 db or more above the rated input signal level. Notes The indicator lights red when the signal level is set too high. In such cases, decrease the output level of connected equipment so that the indicator lights green. Only when the D-93AE or the D-937SP Digital input module is used, the input channel indicator flashes red if a status error occurs. : Lights when the channel is selected and active. 7. Input Volume ontrol [INPUT] Adjusts the gain of the input channel selected with the Input hannel Selector keys (5). 8. Input hannel /OFF Key [] Enables or disables the channel selected with the Input hannel Selector keys (5). 9. Input hannel /OFF Indicator Lights continuously to indicate that the input channel selected with the Input hannel Selector keys (5) is enabled (). 9

10 Microphone Bus ontrol Section Microphone bus indicator () to light, and allows feedback suppression (p. 54), effect (echo) (p. 55), and bus assignment (p. 56) to be set on the LD screen.. Microphone Bus Indicator Remains lit while the microphone bus is selected. 0 Output hannel ontrol Section Output Signal Level Meter Indicates the signal level of the channel selected with the Output hannel Selector keys (8). 6. Output hannel Indicators [, SIG, SEL] : Lights when the channel is active. SIG Indicates the output signal level in two colors (red and green). The status of indicator shows as follows depending on the output signal levels. Red: Signal level is 7 db or more above the rated output signal level. Green: Signal level is between 40 db and +7 db on the basis of the rated output signal level. OFF: PEAK +db +6dB 0dB -6dB -db -0dB -40dB OUTPUT SEL FBS EFFET MI BUS 0. Microphone Bus Selector Key [SEL] Used to set the microphone bus parameters or adjust the volume. Pressing this key causes the 0N SIG SEL Signal level is lower than 40 db below the rated output signal level.. Feedback Suppression Indicator [FBS] Remains lit while the feedback suppression function is enabled. 3. Effect Key [EFFET] The effect (echo) function is enabled when this key is pressed, and the effect (echo) parameters are displayed on the LD screen, allowing settings to be changed. Pressing the key again disables the effect (echo) function. (Refer to p. 55.) 4. Effect Indicator Remains lit while the effect (echo) function is enabled. LED Red Green OFF Output signal level +7 db 40 db Rated output signal level Note The indicator lights red when the signal level is set too high. In such cases, attenuate the unit's output level so that the indicator lights green. SEL: Lights when the output channel is selected. 7. Output Volume ontrol [OUTPUT] Adjusts the gain of the output channel selected with the Output hannel Selector keys (8). 8. Output hannel Selector Keys [ 8] Used to select the output channel for sound volume adjustment, parameter setting or Level meter indication (5). The Output hannel indicator [SEL] (6) lights when the key is pressed, permitting parameter setting, volume adjustment with the Output volume control (7) or Level meter (5) signal level indication. 9. Output hannel /OFF Key [] Enables or disables the channel selected with the Output hannel Selector keys (8). 30. Output hannel /OFF Indicator Lights continuously to indicate that the output channel selected with the Output hannel Selector keys (8) is enabled ().

11 [Rear] RS-3 DIGITAL MIXER model D-90 TOA orporation MADE IN JAPAN SIGNAL GND 4 ontrol module slot Slot 9 Slot 8 Slot 7 Slot 6 Slot 5 Slot 4 Slot 3 Slot Slot Outputs 5 8 Outputs 4 Output module slot Inputs & or Outputs 5 8 Inputs 9 & 0 or Outputs 4 Inputs 7 & 8 Inputs 5 & 6 Inputs 3 & 4 Input module slot Inputs & Input & output module slot 3. ooling Fan AUTI Do not block the fan exhaust vent. Doing so may cause heat to build up inside the unit and result in fire. 3. RS-3 ommunication Port A communications connector for a personal computer (P) or other control equipment. 33. ontrol Module Slot The control module's dedicated slot. 34. Output Module Slot Slot for output channels Output Module Slot Slot for output channels Input/Output Module Slot Slot for input channels and. Inserting an output module here provides output signals for channels Input/Output Module Slot Slot for input channels 9 and 0. Inserting an output module here provides output signals for channels Input Module Slot Slot for input channels 7 and Input Module Slot Slot for input channels 5 and Input Module Slot Slot for input channels 3 and Input Module Slot Slot for input channels and. 4. A Inlet onnect this inlet to the wall A outlet using the supplied power cord. Note Slots 5 8 accommodate only two D-97M and/or D- 97E Line Output Modules together or independently in total.

12 5.. Optional Modules Notes Make sure that the power is switched OFF before attaching or detaching modules. To avoid failures due to static electricity, do not touch the parts or terminals on the circuit board of both the unit and module. Ensure that the module is installed and secured with screws in the correct position. over idle slots with the blank panels attached to the unit as shipped by the factory. Two silver slotted screws at the top and bottom of the front panel are handles used for module detachment. Never rotate them because they do not function as screws. MI/LINE INPUT MODULE GND LIFT Handle 5... D-9F Microphone/Line Input Module MI/LINE INPUT MODULE [ 50 / 36 / 0 / +4 db] model D-9F GND LIFT NORMAL GND LIFT NORMAL : E : H 3 : Monaural Input Terminal [, ] (XLR-3-3 equivalent) Electronically-balanced input terminal. (Pin : Ground; Pin : Hot; Pin 3: old) Use XLR-3- or equivalent for connection. : Hot Input sensitivity ( 50/ 36/ 0/+4 db) and phantom power (+5 V) /OFF can be set by 3: old way of the front panel setting screen. : Ground 44. Ground Lift Switch [GND LIFT/NORMAL] Hum noise may be generated due to ground loops created when the unit is connected to other equipment. Setting the switch to the GND LIFT position cuts the ground loop. AESSORY I.T.E 78K 5... D-9E Microphone/Line Input Module MI/LINE INPUT MODULE [ 50 / 36 / 0 / +4 db] model D-9E E H GND LIFT NORMAL E H GND LIFT NORMAL Monaural Input Terminal [, ] Electronically-balanced, removable terminal block. (H: Hot; : old; E: Ground) Input sensitivity ( 50/ 36/ 0/+4 db) and phantom power (+5 V) /OFF can be set by way the front panel setting screen. 46. Ground Lift Switch [GND LIFT/NORMAL] Hum noise may be generated due to ground loops created when the unit is connected to other equipment. Setting the switch to the GND LIFT position cuts the ground loop. Note Be sure to use the supplied removable terminal plugs (3P) for connection. AESSORY I.T.E 78K

13 5..3. D-9F Microphone/Line Input Module MI/LINE INPUT MODULE model D-9F NORMAL MI NORMAL MI OFF : PHANTOM LIFT : GND LINE +4dB(LINE) -36dB(MI) -0dB(LINE) -50dB(MI) OFF : PHANTOM LIFT : GND LINE +4dB(LINE) -36dB(MI) -0dB(LINE) : E -50dB(MI) : H 3 : AESSORY I.T.E 78K Monaural Input Terminal [, ] (XLR-3-3 equivalent) Electronically-balanced input terminal. (Pin : Ground; Pin : Hot; Pin 3: old) Use XLR-3- or equivalent for connection. 3: old 48. Input Sensitivity Switch [PHANTOM, GND LIFT, MI/LINE] 4-pole switch. Enables phantom power (+5 V; /OFF, enabled only when set to the MI position), ground lift and input sensitivity. Input sensitivity: 36 or 50 db (MI mode) / 0 or +4 db (LINE mode) NORMAL MI -0dB(LINE) -50dB(MI) OFF : PHANTOM LIFT : GND LINE +4dB(LINE) -36dB(MI) : Hot : Ground D-9E Microphone/Line Input Module MI/LINE INPUT MODULE model D-9E NORMAL MI NORMAL MI E H OFF : PHANTOM LIFT : GND LINE +4dB(LINE) -36dB(MI) -0dB(LINE) -50dB(MI) E H OFF : PHANTOM LIFT : GND LINE +4dB(LINE) -36dB(MI) -0dB(LINE) -50dB(MI) AESSORY I.T.E 78K Monaural Input Terminal [, ] Electronically-balanced, removable terminal block. (H: Hot; : old; E: Ground) Note Be sure to use the supplied removable terminal plugs (3P) for connection. 50. Input Sensitivity Switch [PHANTOM, GND LIFT, MI/LINE] 4-pole switch. Enables phantom power (+5V; /OFF, enabled only when set to the MI position), ground lift and input sensitivity. Input sensitivity: 36 or 50 db (MI mode) / 0 or +4 db (LINE mode) NORMAL MI -0dB(LINE) -50dB(MI) OFF : PHANTOM LIFT : GND LINE +4dB(LINE) -36dB(MI) D-936R Stereo Input Module STEREO SELET INPUT MODULE [ 0 db] R R 3R L L 3L 5 5. Stereo Input Terminal [L/R, L/R, 3L/3R, 4L/4R] Unbalanced, RA pin jack stereo input terminals. Either a single stereo input can be selected from the 4 available stereo inputs or all 4 stereo channels can be mixed. Mode setting and stereo selection are performed at the front panel setting screen. They can also be remotely selected by way of connected external equipment through the use of the control module. Input signal level: 0 db 4R 4L model D-936R AESSORY I.T.E 78K 3

14 5..6. D-93AE Digital Input Module D-97M Line Output Module DIGITAL INPUT MODULE model D-93AE DIGITAL IN AES/EBU / 5 LINE OUTPUT MODULE [+4 db] model D-97M 3 4 : E : H 3 : 55 AESSORY I.T.E 78K 5. AES/EBU Digital Input Terminal [AES/EBU, /] (XLR-3-3 equivalent) Digital input terminal of AES/EBU format. (Pin : Ground; Pin : Signal; Pin 3: Signal) 3: Signal : Signal : Ground Use the XLR-3- or its equivalent for connection. Note Use a digital audio cable with characteristic impedance of 0 Ω for connection. 55. Monaural Output Terminal [,, 3, 4] (XLR-3-3 equivalent) Electronically-balanced output terminal. (Pin : Ground; Pin : Hot; Pin 3: old) 3: old : Hot : Ground Output signal level: +4dB Use XLR-3- or equivalent for connection D-97E Line Output Module D-937SP Digital Input Module DIGITAL INPUT MODULE OPTIAL DIGITAL IN 53 LINE OUTPUT MODULE [+4 db] E H E H 56 E 3 H 4 model D-937SP OAXIAL Optical Input Terminal [OPTIAL,,] Optical input terminal of S/PDIF format oaxial Input Terminal [OAXIAL 3, 4] oaxial input terminal of S/PDIF format. Notes Use a coaxial cable with characteristic impedance of 75 Ω for connection. One of four line inputs (stereo) is selected. Input selection is performed at the front panelmounted setting screen. model D-97E E H 4 AESSORY I.T.E 78K 56. Monaural Output Terminal [,, 3, 4] Electronically-balanced, removable terminal block. (H: Hot; : old; E: Ground.) Output signal level: +4 db Note Be sure to use the supplied removable terminal plugs (3P) for connection.

15 5..0. D-97R Line Output Module 5... D-96SP Digital Output Module LINE OUTPUT MODULE [ 0 db] (R) (L) 57 DIGITAL OUTPUT MODULE DIGITAL OUT OPTIAL OAXIAL OPTIAL 4(R) 3(L) OAXIAL model D-96SP model D-97R AESSORY I.T.E 78K 57. Monaural Output Terminals [(L), (R), 3(L), 4(R)] Unbalanced, RA pin jack output terminals. Each output is equipped with a -channel splitter. Output signal level: 0 db 5... D-97AE Digital Output Module DIGITAL OUTPUT MODULE model D-97AE DIGITAL OUT AES/EBU AES/EBU / 3/ AES/EBU Digital Output Terminal [AES/EBU, /] (XLR-3-3 or its equivalent) Digital output terminal of AES/EBU format. (Pin : Ground; Pin : Signal; Pin 3: Signal) 59. Optical Output Terminal [OPTIAL, ] Optical output terminal of S/PDIF format. 60. oaxial Output Terminal [OAXIAL, ] oaxial input/output terminal of S/PDIF format. Note Use a coaxial cable with characteristic impedance of 75 Ω for connection. Each pair of the S/PDIF optical output and the coaxial RA pin jack output delivers output in parallel D-98 Remote ontrol Module REMOTE TROL MODULE model D INPUT OUTPUT 6 6 AESSORY I.T.E 78K 3: Signal : Ground : Signal Use the XLR-3- or its equivalent for connection. Note Use the digital audio cable with characteristic impedance of 0 Ω for connection. 6. ontact Input Terminal [INPUT,,,, 3, 4, 5, 6, 7, 8, ] Removable terminal block, 8-circuit contact input terminal. Individual contact functions are assigned on the front panel setting screen. Note Be sure to use the supplied removable terminal plugs (0P) for connection. 6. ontact Output Terminal [OUTPUT,,,, 3, 4, 5, 6, 7, 8, ] Removable terminal block, 8-circuit contact output terminal. Individual contact functions are assigned on the front panel setting screen. 5

16 5..4. D-983 Remote ontrol Module REMOTE TROL MODULE model D-983 TRL OUT TRL IN TROL UNITS FOR D-90 LY ontact Input Terminal [TRL IN, -6, 7-, 3-8, 9-4] Six-circuit RJ45 contact input Pin No. terminals. Assign functions to each contact on the front panel-mounted setting screen. 64. ontact Output Terminal [TRL OUT,-4, 5-8, 9-, 3-6] Four-circuit RJ45 contact output terminals. Assign functions to each Pin No. contact on the front panel-mounted setting screen IN IN IN 3 IN 6 IN 5 IN 4-4 OUT OUT 3 OUT 3 OUT 4 4 TRL IN 7- IN 7 IN 8 IN 9 IN IN IN IN 3 IN 4 IN 5 IN 8 IN 7 IN 6 TRL OUT 5-8 OUT 5 5 OUT 6 7 OUT 7 6 OUT OUT 9 9 OUT 0 OUT 0 OUT 9-4 IN 9 IN 0 IN IN 4 IN 3 IN 3-6 OUT 3 3 OUT 4 5 OUT 5 4 OUT D-984V VA ontrol Module VA TROL MODULE model D-984V TRL IN TRL OUT VA IN H OUT H TROL UNITS FOR D-90 LY Input channel VA Terminal [IN H, -6, 7-] RJ45 VA terminals. Pin No. These RJ45 VA terminals correspond to input channels. 66. Output hannel VA Terminal [OUT H, -4, 5-8] RJ45 VA terminals. These RJ45 VA terminals Pin No. correspond to 8 output channels IN H IN H IN H 3 IN H 6 IN H 5 IN H 4 V -4 OUT H OUT H OUT H 3 V OUT H 4 V IN H 7- IN H 7 IN H 8 IN H 9 IN H IN H IN H 0 V OUT H 5-8 OUT H 5 OUT H 6 OUT H 7 V OUT H 8 V 67. ontrol Input Terminal [TRL IN, -4, 5-8] RJ45 ontrol Input terminals. These RJ45 ontrol Input terminals correspond to 8 control inputs. Pin No TRL IN TRL IN TRL IN 5 TRL IN TRL IN 6 TRL IN 3 TRL IN 7 TRL IN 4 TRL IN 8 V V ontrol Output Terminal [TRL OUT, -4, 5-8] RJ45 ontrol output terminals. Pin No. These RJ45 ontrol output terminals correspond to 8 control outputs TRL OUT TRL OUT 3 TRL OUT 3 TRL OUT 4 4 TRL OUT 5-8 TRL OUT 5 5 TRL OUT 6 7 TRL OUT 7 6 TRL OUT 8 8

17 6. SETTING BASIS 6.. Setting Procedures The D-90's functions need to be set using the front-mounted keys and knob according to scenes of use. After connecting all external equipment, check the following, then follow the procedures below to set each of the unit's functions. heck to be sure that The required modules are correctly inserted. The power supply is correctly connected. The power indicator lights when the power switch is turned on. Step. Set which input channel signal is transmitted to which output channel. Because the factory default setting is made so that each input ( ) is assigned to all outputs ( 8) via the Microphone Bus*, when a microphone, or D player or other music player is connected to an input, its signals are output from all output terminals by simply increasing the corresponding input channel gain. Make input-to-output re-assignment according to scenes of use. * Refer to p. 8, Block Diagram. (Refer to p. 4, Bus assignment settings.) This setting can be performed in either of two ways: On the setting screen display or by way of the front-mounted keys. Step. Set the input sensitivity. When the D-9E or D-9F is installed, perform this setting by displaying the setting screen. (Refer to p. 6, PAD Settings.) When the D-9E or D-9F is installed, perform this setting using its DIP switch. (Refer to p. 3.) Set the sensitivity so that the front-mounted Input channel indicator [SIG] does not light red. Step 3. Set the input channel gain. (Refer to p. 5, Input/Output Gain Settings.) This setting can be performed in any of three ways: On the setting screen display (two methods) or by way of the front-mounted keys. Note: When using the D-984V VA ontrol Module, perform gain settings as well for the input channel to be remotely controlled. Step 4. Set the output channel gain. (Refer to p. 5, Input/Output Gain Settings.) This setting can be performed in any of three ways: On the setting screen display (two methods) or by way of the front-mounted keys. Note: When using the D-984V VA ontrol Module, perform gain settings as well for the output channel to be remotely controlled. Step 5. Set individual functions as required. (Refer to p. 8, Setting Flowcharts.) Refer to the setting flowcharts for the appropriate setting method for the function to be used. When using Stereo Link, Grouping and rossover functions, first perform the required settings on the Utility setting screen. 7

18 Note It is highly recommended that any changed parameters be immediately saved as preset memory on the Preset Memory setting screen. (Refer to p. 57, Preset Memory Save.) This permits the parameters of each function to be saved and protected, even if the power is switched off. All currently saved parameters can be recalled and reproduced when the power is switch on again. (Refer to p. 60, Initial Preset Memory Selection.) Settings need not be saved when temporarily setting or changing parameters. 6.. Setting Flowcharts All the functions described hereinafter can also be set at a P using the dedicated software. Please access our website " for its download. In the following charts, the Screen shift keys [ ] are used to move vertically (next screen display) and the shift keys [ ] to move horizontally between the solid line setting screen boxes ( ). For movements within the dotted line setting screen boxes ( ) and parameter settings for each setting screen, refer to the corresponding pages Input and output settings (Only when using the D-9E or D-9F Microphone/Line Input Module) (Only when using the D-93AE Digital Input Module) hannel Status Verification (p. 7) Phantom power /OFF Settings (Only when the PAD is set to "MI.") (p. 6) Input signal status verification Sampling frequency verification Pre-emphasis verification PAD (Input Sensitivity) Settings (p. 6) (Only when using the D-937SP Digital Input Module) hannel Status Verification (p. 7) (Only when using the D-936R Stereo Input Module) Line Input Mode Selection (p. 6) Line (Stereo) Input Selection (p. 8) Input signal status verification Line (Stereo) Input Selection (p. 8) Input trim settings (p. 8) Sampling frequency verification Pre-emphasis verification Input Gain Settings Input Trim Gain Settings Input trim polarity settings High-pass filter settings (p. 9) utoff Frequency Settings Q settings Equalizer settings (p. 30) Gain Settings (low frequency) Gain Settings (high frequency) enter frequency settings Q settings enter frequency settings Q settings 8 (To next page) (To next page)

19 (From the previous page) (From the previous page) ompressor/auto-leveler Mode Selection (p. 3) (ompressor mode) (Auto-leveler mode) ompressor settings (p. 3) Threshold Level Settings Ratio settings Attack time settings Release time settings Makeup gain settings Auto-leveler settings (p. 33) Target Level Settings Maximum gain settings Attack time settings Release time settings Level sense settings (p. 34) Attack Time Settings Release time settings Gate settings (p. 35) Threshold Level Settings Hysteresis settings Depth settings Hold time settings Attack time settings Release time settings Auto-Mixing Group Settings (p. 37) Ducker settings (p. 38) Priority Settings Attenuation settings Attack time settings Release time settings NOM Attenuation /OFF Settings (p. 39) Input hannel Gain Settings (p. 40) Input hannel Group Trim Gain Settings (p. 40) (Only when Group is set) Bus assignment and crosspoint gain settings (p. 4) Bus Assignment Settings rosspoint gain settings 3 (To next page) 9

20 3 (From the previous page) Input Gain Settings Same items as for Input Output Gain Settings Output hannel Gain Settings (p. 4) Output hannel Group Trim Gain Settings (p. 4) (Only when Group is set) rossover settings (Only when rossover function is enabled) (p. 43) Slope Settings (High Frequency) Slope Settings (Low Frequency) utoff frequency settings Q settings Q settings rossover gain settings rossover filter polarity settings Same items as for high frequency Filter settings (p. 45) Filter Settings (Type Selection) Parametric equalizer High-pass filter (6 db/ db) Low-pass filter (6 db/ db) High shelving filter Low shelving filter Horn equalizer Notch filter All-pass filter Filter 6* Settings (Type Selection) Same items as for Filter ompressor settings (p. 50) Threshold Level Settings Ratio settings Attack time settings Release time settings Makeup gain settings Delay Time Settings (p. 5) Output 8 Gain Settings Same items as for Output * The number of filters to be displayed differs depending on crossover configuration settings. (Refer to p. 6.) 0

21 6... Microphone bus settings Microphone bus selector key SEL Feedback suppression settings (p. 5) Dynamic Mode Settings Auto mode activation Filter number settings Dynamic mode filter initialization Auto mode filter initialization Feedback suppression filter setting confirmation (p. 54) Mode onfirmation (Filter settings) Frequency confirmation Filter gain confirmation Q confirmation Mode onfirmation (Filter settings) Same items as for Filter Effect key EFFET Effect (echo) settings (p. 55) Echo Gain Settings Feedback ratio settings Feedback delay settings Initial echo (pre-) delay settings Low-pass filter frequency settings Low-pass filter Q settings Bus assignment and crosspoint gain settings (p. 56) Bus Assignment Settings rosspoint gain settings Preset memory settings Preset key PRESET Preset Memory Save (p. 57) Preset Memory Recall (p. 58) Preset Memory Delete (p. 58) Preset Memory rossfade Time Settings (p. 59) Initial Preset Memory Selection (p. 60) onfiguration Save (p. 60)

22 6..4. Utility settings Utility key UTILITY Stereo Link Settings (p. 6) Group Settings (p. 6) rossover onfiguration Settings (p. 6) NOM Attenuation Settings (p. 64) ontact input/output settings (p. 65) (Only when using the D-98 or D-983 Remote ontrol Module, or D-984V VA ontrol Module) Input ontact Number Selection Output ontact Number Selection Preset memory recall Volume UP Volume DOWN hannel /OFF Line (stereo) input selection Normal make/break Preset memory recall tally hannel /OFF tally ontact input status tally Line (stereo) input selection tally Protect Settings (p. 68) Operation key protection /OFF RS-3 port settings (p. 70) ontrol Mode Selection RS-3 transmission rate settings All Input/Output hannel Gain onfirmation (p. 7) Gain confirmation for all input channels Gain confirmation for all 8 output channels (Only when using the D-984V VA ontrol Module) All Input/Output VA Status onfirmation (p. 7) VA status confirmation for all input channels VA status confirmation for all 8 output channels Module type confirmation (p. 7) Individual Slots onfirmation All slots confirmation ooling Fan Operating Status onfirmation (p. 73) Firmware Version onfirmation (p. 73)

23 6.3. Setting Keys and Knob Parameter input section DIGITAL MIXER model D-90 Screen shift keys Utility key Preset key UTILITY PRESET LOK Setting knob ENTRY SETI 5 6 Function /OFF key PRESET Preset memory selection section Preset memory selector keys Input channel control section Microphone bus control section Output channel control section 7 PEAK 8 +db +6dB 3 9 0dB dB SEL SIG 0N 0N SIG SEL SEL -db -0dB -40dB FBS 0N SIG SEL 8 EFFET INPUT MI BUS OUTPUT Input channel selector keys Input volume control Microphone bus selector key Effect key Output volume control Output channel selector keys Input channel /OFF key Output channel /OFF key 3

24 6.4. Setting Screen Displays [Input/Output Gain Setting Screen Example] Indicates the object currently being set. In this example, IN (Input ) is the object being set. Pressing the shift key here switches the display to the input trim gain setting screen. The [IN ] TRIM indication is displayed on the first line, and the IN (Input ) trim gain becomes the setting object. The channel selected with the Input channel selector key is displayed. The channel selected with the Output channel selector key is displayed. IN ] [OUT] I N F d B 0. 0 d B The gain of the input channel is displayed. In this example, the gain of Input channel is displayed. Setting values can be changed using the Input volume control. The gain of the output channel is displayed. In this example, the gain of Output channel is displayed. Setting values can be changed using the Output volume control. [Equalizer Setting Screen Example] The channel number for which settings are to be changed is displayed. The object currently being set is displayed. [ I N ] P EQ - H GA I N d B Displayed when the previous screen exists. In this case, the PEQ-L (low frequency equalizer) setting screen appears when the shift key is pressed. Displayed when the next screen exists. In this case, the OMPMODE (compressor/auto-leveler) setting screen appears when the shift key is pressed. Setting items are displayed. In this example, the PEQ-H (high frequency equalizer) gain is being set. To change the frequency or Q of PEQ-H, press the shift key. The setting item display changes to FREQ and Q each time the shift key is pressed. Parameters and selection contents can be changed with the Setting knob. In this example, the equalizer gain can be changed. 4

25 7. INPUT/OUTPUT GAIN SETTINGS There are 3 possible setting methods. 7.. Input and Output hannel ontrol Section Settings Step. Press the desired Input (or Output) channel selector key. The selected channel's SEL indicator lights. Note When Group setting is performed, selecting a channel in the group allows all SEL indicators of the input channels grouped together to light all at once. Step. Rotate the Input (or Output) volume control to set the gain. (Example: Input channel gain setting) SEL SIG 0N 0N SIG SEL SEL FBS EFFET PEAK +db +6dB 0dB -6dB -db -0dB -40dB 0N SIG SEL Input/output gain setting range: INF ( ) to +0 db INPUT MI BUS OUTPUT 7.. Input/Output Gain Setting Screen Operation Step. Press the desired Input (or Output) channel selector key. Step. Using the Screen shift key, display the input (or output) gain setting screen. Step 3. Rotate the Setting knob to set the gain. I N ] [ OU T ] INFdB 0.0dB Input channel gain setting IN] [OUT] INFdB 0.0dB Input channel gain setting [ I N ] OU T ] I N F d B 0. 0 d B Output channel gain setting [ I N ] OU T 8 ] I N F d B 0. 0 d B Output channel 8 gain setting 7.3. Input/Output hannel Gain Setting Screen Operation Perform the "Input hannel Gain Settings" (p. 40) and "Output hannel Gain Settings" (p. 4). 5

26 8. INPUT-RELATED SETTINGS The channel selected with the Input channel selector keys can be enabled or disabled using the Input channel /OFF key. To enable or disable individual functions, use the function /OFF key when each function is displayed. 8.. Phantom Power /OFF Settings (Only with D-9E or D-9F module) [ IN ] PHANTOM OFF (Only when the PAD is set to "MI.") an be displayed and set only when MI is selected on the PAD setting screen (explained in the next section). Enable or disable phantom power using the function /OFF key. Note Signals are muted for a specified period of time while changing settings. Pressing the Input channel selector key for the channel in which the D-9E or D-9F module is installed permits phantom power setting for that channel. The [IN ] indication changes to the selected channel number indication. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed. 8.. PAD (Input Sensitivity) Settings (Only with D-9E or D-9F module) [ I N ] P AD L I N E + 4 d B Input trim gain settings (p. 8) Rotate the Setting knob to set the PAD (input sensitivity). Parameter setting range: MI: 50 or 36 db LINE: 0 or +4dB Note Signals are muted for a specified period of time while changing settings. Pressing the Input channel selector key for the channel in which the D-9E or D-9F module is installed permits PAD selection for that channel. The [IN ] indication changes to the selected channel number indication. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed Line Input Mode Selection (Only with D-936R module) [ I N ] L I N E I N MIX ALL Line (stereo) input selection (p. 8) Rotate the Setting knob to select the D-936R Stereo Input Module operation mode. Either a single stereo input can be selected from among the 4 available stereo inputs (SELET mode) or all 4 stereo channels can be mixed (MIX ALL mode). Also, in MIX ALL mode, stereo sources can be selected with the input selection screen. (Refer to p. 8.) Note Signals are muted for a specified period of time while changing settings. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed. 6

27 8.4. hannel Status Verification (Only with D-93AE or D-937SP module) Input signal status verification [ I N ] S T A T U S L O K Sampling frequency verification [ I N ] S T A T U S Fs 48kHz Pre-emphasis verification [ I N ] S T A T U S EMPHAS I S NE Using D-93AE: Input trim settings (next page) Using D-937SP: Line (stereo) input selection (next page) Input signal status verification [ I N ] STATUS LOK Input signal status of each channel can be verified. Display Input signal status LOK Normal UNLOK No cable connected or equipment power not turned on Non AUDIO Not an audio signal Non PM Not PM data DTS D DTS D Sampling frequency verification [ I N ] STATUS Fs 48kHz Sampling frequencies can be verified. Display example: 3 khz, 44. khz, 48 khz, 88. khz, 96 khz The indication of [ ] is displayed when it is impossible to recognize. Sampling rate converter (SR) is always Pre-emphasis verification [ I N ] STATUS EMPHAS I S NE The "DETET" indication is displayed when pre-emphasis is detected, automatically turning on the de-emphasis. [ I N ] STATUS EMPHAS I S DETET The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed. 7

28 8.5. Line (Stereo) Input Selection (Only with D-936R or D-937SP module) Using D-936R: Line input mode selection (p. 6) Using D-937SP: hannel status verification (previous page) [ I N ] L I N E S E L [ ] 3 4 Rotate the Setting knob to select the line (stereo) number and press the function /OFF key to enable or disable the input. For example, when the [IN ] indication is displayed, settings are performed for the stereo module inserted into the unit's rearmounted IN and slot. The " " indication is displayed when disabled. There are two operation modes for the module: MIX ALL and SELET modes. (MIX ALL mode is provided with the D-936R only.) MIX ALL mode: Mixes 4 (stereo) line inputs. Any individual stereo input can also be disabled. SELET mode: Selects a single (stereo) line input. Trim settings can be performed for individual line inputs. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed Input Trim Settings Using D-9F or D-9E: PAD (Input sensitivity) settings (p. 6) Using D-936R or D-937SP: Line (stereo) input selection (previous section) Using D-93AE: hannel status verification (previous page) Gain [ I N ] T R I M d B Polarity [ I N ] T R I M POL NORMAL High-pass filter settings (next page) Input trim gain settings [ I N ] T R I M d B Rotate the Setting knob to set the input trim gain. Parameter setting range: 5 to +5 db in 0. db steps Pressing an Input channel selector key allows the trim to be adjusted for that channel. The [IN ] indication changes to the selected channel number indication. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed Input trim polarity settings [ I N ] T R I M POL NORMAL Rotate the Setting knob to set the input trim polarity. Parameter setting range: NORMAL, INVERSE Pressing an Input channel selector key allows the trim to be adjusted for that channel. The [IN ] indication changes to the selected channel number indication. 8

29 8.7. High-Pass Filter Settings The high-pass filter function can be enabled or disabled for the displayed channel by using the function /OFF key even when any of the following screens is displayed. The function /OFF Indicator lights when enabled (). [Screen display operations] Input trim settings (previous page) utoff frequency [ I N ] H P F FREQ 60Hz Q [ I N ] H P F Q Equalizer settings (next page) utoff frequency settings [ I N ] H P F FREQ 60Hz Rotate the Setting knob to set the high-pass filter cutoff frequency. Parameter setting range: 0 Hz 0 khz in /4 octave steps Note: Slope is fixed at db/oct. Pressing an Input channel selector key permits the high-pass filter to be set for that channel. The [IN ] indication changes to the selected channel number indication. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed Q settings [ I N ] H P F Q Rotate the Setting knob to set the high-pass filter Q. Parameter setting range: (5 points) Pressing an Input channel selector key permits the high-pass filter to be set for that channel. The [IN ] indication changes to the selected channel number indication. 9

30 8.8. Equalizer Settings When the (low or high frequency) Equalizer setting screen is displayed, equalization for the displayed channel can be enabled or disabled by pressing the function /OFF key. When enabled (), the function /OFF indicator lights. [Screen display operations] High-pass filter settings (previous page) (Low frequency) Gain enter frequency Q [ I N ] P EQ - L GAIN +0.0dB [ I N ] P EQ - L FREQ Hz [ I N ] P EQ - L Q (High frequency) [ I N ] P EQ - H GAIN +0.0dB [ I N ] P EQ - H FREQ. 5kHz [ I N ] P EQ - H Q ompressor/auto-leveler mode selection (next page) Gain settings (Low frequency) [ I N ] P EQ - L GAIN +0.0dB (High frequency) [ I N ] P EQ - H GAIN +0.0dB Rotate the Setting knob to set the gain. Parameter setting range: 5 to +5 db in 0. db steps Pressing an Input channel selector key permits the equalizer gain to be set for that channel. The [IN ] indication changes to the selected channel number indication. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed enter frequency settings (Low frequency) [ I N ] P EQ - L F R EQ H z (High frequency) [ I N ] P EQ - H F R EQ. 5 k H z Rotate the Setting knob to set the center frequency. Parameter setting range: 0 Hz 0 khz in /4 octave steps Pressing an Input channel selector key permits the equalizer center frequencies to be set for that channel. The [IN ] indication changes to the selected channel number indication Q settings (Low frequency) [ I N ] P EQ - L Q (High frequency) [ I N ] P EQ - H Q Rotate the Setting knob to set the Q. Parameter setting range: (96 points) Pressing an Input channel selector key permits the equalizer Q to be set for that channel. The [IN ] indication changes to the selected channel number indication. 30

31 8.9. ompressor/auto-leveler Mode Selection Select which function to use, compressor (next section) or auto-leveler (p. 33). Equalizer Settings (previous page) [ I N ] OMPMODE O M P ompressor settings (next section) or auto-leveler settings (p. 33) Rotate the Setting knob to select compressor mode (OMP) or auto-leveler mode (LEVELER). Selecting the mode enables its corresponding function. Refer to the next section for the compressor settings, and p. 33 for the auto-leveler settings. hanging the mode cancels the parameters for the newly selected mode even they have been preset, returning them to the default settings. Pressing an Input channel selector key permits the compressor mode or the auto-leveler mode to be set for that channel. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed ompressor Settings (only when the compressor mode is selected in Section 8.9.) Note No following displays appear when the auto-leveler mode is selected. When any of the following screens is displayed, the compression function for the displayed channel can be enabled or disabled with the function /OFF key. When enabled (), the function /OFF Indicator lights. [Screen display operations] ompressor/auto-leveler mode selection (previous section) Threshold level Ratio Attack time Release time Makeup gain [ I N ] OMP T H R E S H + 0 d B [ I N ] OMP RATIO : [ I N ] OMP ATTAK 0. 0 m s [ I N ] OMP R E L E A S E m s [ I N ] OMP GA I N + 0d B Level sense settings (p. 34) Threshold level settings [ I N ] OMP THRESH +0dB Rotate the Setting knob to set the threshold level. Parameter setting range: 0 to +0 db in db steps Pressing an Input channel selector key permits the compression threshold level to be set for that channel. The [IN ] indication changes to the selected channel number indication. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed. 3

32 8.0.. Ratio settings [ I N ] OMP RATIO : Rotate the Setting knob to set the ratio. Parameter setting range: :, :, 3:, 4:, 8:, :, 0:, INF ( ): Pressing an Input channel selector key permits the compression ratio to be set for that channel. The [IN ] indication changes to the selected channel number indication Attack time settings [ I N ] OMP ATTAK 0. 0 m s Rotate the Setting knob to set the attack time. Parameter setting range: 0. ms 5 s (Refer to p. 85 for more information.) Pressing an Input channel selector key permits the compression attack time to be set for that channel. The [IN ] indication changes to the selected channel number indication Release time settings [ I N ] OMP R E L E A S E m s Rotate the Setting knob to set the release time. Parameter setting range: 0 ms 5 s (Refer to p. 85 for more information.) Pressing an Input channel selector key permits the compression release time to be set for that channel. The [IN ] indication changes to the selected channel number indication Makeup gain settings [ I N ] OMP GA I N + 0d B Rotate the Setting knob to set the makeup gain. Parameter setting range: INF ( ) to +0 db, in db steps Pressing an Input channel selector key permits the compression makeup gain to be set for that channel. The [IN ] indication changes to the selected channel number indication. 3

33 8.. Auto-Leveler Settings (only when the auto-leveler mode is selected in Section 8.9.) The auto-leveler function performs to keep the output level constant by suppressing the change of sound volume. Setting the target level (the constant level to be automatically adjusted to) and the maximum gain (the amount of gain to bring the lower level to the target level) automatically compensates for the input level. Note that setting an excessive amount of gain increases the input sensitivity, easily causing feedback. Note: No following displays appear when the compressor mode is selected. When any of the following screens is displayed, the auto-leveler function for the displayed channel can be enabled or disabled with the function /OFF key. When enabled (), the function /OFF Indicator lights. [Screen display operations] ompressor/auto-leveler mode selection (p. 3) Target level Maximum gain Attack time Release time [ I N ] LEVELER T A R G E T + 0 d B [ I N ] L E V E L E R MAX GA I N + 0 db [ I N ] L E V E L E R ATTAK 500ms [ I N ] L E V E L E R R E L E A S E. 0 0 s Level sense settings (next page) 8... Target level settings [ I N ] LEVELER TARGET +0dB Rotate the Setting knob to set the target level. Parameter setting range: 0 to +0 db in db steps Pressing an Input channel selector key set for the auto-leveler mode permits the auto-leveler target level to be set for that channel. The [IN ] indication changes to the selected channel number indication. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed Maximum gain settings [ I N ] L E V E L E R MAX GAIN +0dB Rotate the Setting knob to set the maximum gain. Parameter setting range: 0 to +0 db in db steps Pressing an Input channel selector key set for the auto-leveler mode permits the auto-leveler maximum gain to be set for that channel. The [IN ] indication changes to the selected channel number indication Attack time settings [ I N ] L E V E L E R ATTAK 500m s Rotate the Setting knob to set the attack time. Parameter setting range: 0 ms 0 s (Refer to p. 86 for more information.) Pressing an Input channel selector key set for the auto-leveler mode permits the auto-leveler attack time to be set for that channel. The [IN ] indication changes to the selected channel number indication. 33

34 8..4. Release time settings [ I N ] L E V E L E R R E L E A S E. 0 0 s Rotate the Setting knob to set the release time. Parameter setting range: 00 ms 0 s (Refer to p. 86 for more information.) Pressing an Input channel selector key set for the auto-leveler mode permits the auto-leveler release time to be set for that channel. The [IN ] indication changes to the selected channel number indication. 8.. Level Sense Settings The level sense refers to a parameter used to adjust the sensitivity by which the gate detects an input signal level. Proper attack time settings prevent the gate function from being accidentally triggered by pulse noise. (Refer to the next page.) [Screen display operations] ompressor settings (p. 3) or Auto-leveler settings (previous page) Attack time [ I N ] L e v e l ATTAK 0. m s Release time [ IN ] Leve l RELEASE 0 0m s Gate settings (next page) 8... Attack time settings [ I N ] L e v e l ATTAK 0. m s Rotate the Setting knob to set the attack time. Parameter setting range: 0. ms 5 s (Refer to p. 86 for more information.) Pressing an Input channel selector key permits the level sense attack time to be set for that channel. The [IN ] indication changes to the selected channel number indication. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed Release time settings [ I N ] L e v e l R E L E A S E 0 0 m s Rotate the Setting knob to set the release time. Parameter setting range: 0 ms 5 s (Refer to p. 86 for more information.) Pressing an Input channel selector key permits the level sense release time to be set for that channel. The [IN ] indication changes to the selected channel number indication. 34

35 8.3. Gate Settings The gate function allows the input signal to be passed, attenuated or cut depending on its signal level. The gate allows the signal to pass when open, and attenuates or cuts the signal when closed. The gate opens when the input signal reaches a level above the Threshold plus Hysteresis parameter (half the Hysteresis) as shown in the figure at right. Once open, the input signal must reach a level below the Threshold minus Hysteresis parameter to close.the Ducker function (p. 38) and the NOM attenuation function (p. 39) are controlled by the gate's open/close operations. [Example: Hysteresis parameter is set to +0 db.] Input level Open +0 db Hysteresis Threshold level -0 db losed When any of the following screens is displayed, the gate function for the displayed channel can be enabled or disabled with the function /OFF key. When enabled (), the function /OFF Indicator lights. Note: When an input channel is set to OFF, the gate function on that channel does not operate. [Screen display operations] Level sense settings (previous page) Threshold level Hysteresis Depth Hold time [ I N ] GA T E THRESH 40dB [ I N ] GA T E HYST +0dB [ I N ] GA T E DEPTH 0dB [ I N ] GA T E HOLD 0. 0m s To A Attack time Release time Auto-mixing group settings (p. 37) A [ I N ] GA T E ATTAK 0. 0m s [ I N ] GA T E RELEASE 0. 0m s Threshold level settings [ I N ] GA T E THRESH 40dB Rotate the Setting knob to set the threshold level. Parameter setting range: 50 to +0 db in db steps Pressing an Input channel selector key permits the gate threshold level to be set for that channel. The [IN ] indication changes to the selected channel number indication. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed Hysteresis settings [ I N ] GA T E HYST +0dB Rotate the Setting knob to set the hysteresis (the difference between the input signal levels used to open and close the gate). Parameter setting range: 0 to +0 db in db steps Pressing an Input channel selector key permits the gate hysteresis to be set for that channel. The [IN ] indication changes to the selected channel number indication. 35

36 Depth settings [ I N ] GA T E DEPTH 0dB Rotate the Setting knob to set the depth (signal attenuation when the gate is closed). Parameter setting range: INF ( ) to 0 db in db steps Pressing an Input channel selector key permits the gate depth to be set for that channel. The [IN ] indication changes to the selected channel number indication Hold time settings [ I N ] GA T E HOLD 0. 0 m s Rotate the Setting knob to set the hold time (the interval the gate is kept open when an input signal level drops below the closing threshold level). Parameter setting range: 0 ms 0 s (Refer to p. 86 for more information.) Pressing an Input channel selector key permits the gate hold time to be set for that channel. The [IN ] indication changes to the selected channel number indication Attack time settings [ I N ] GA T E ATTAK 0. 0 m s Rotate the Setting knob to set the attack time (the time required for the gate to open). Parameter setting range: 0 ms 0 s (Refer to p. 86 for more information.) Pressing an Input channel selector key permits the gate attack time to be set for that channel. The [IN ] indication changes to the selected channel number indication Release time settings [ I N ] GA T E RELEASE 0. 0 m s Rotate the Setting knob to set the release time (the time required for attenuation to reach the gain set in the depth setting when the gate is closed). Parameter setting range: 0 ms 0 s (Refer to p. 86 for more information.) Pressing an Input channel selector key permits the gate release time to be set for that channel. The [IN ] indication changes to the selected channel number indication. 36

37 8.4. Auto-Mixing Group Settings Both the Ducker function (next page) and the NOM Attenuation function (p. 39) are Auto-Mixing Functions that automatically adjust individual input channel gains in response to input signal level. The auto-mixing functions can operate in each of the 4 groups, GROUP A through D. Although all the input channels are grouped into GROUP A by default, they can be individually assigned to the desired groups. The figure below shows the block diagram of the Auto-Mixing (Auto MIX) section. [Auto-mixing block diagram] The diagram below shows an example where the input channels and are assigned to GROUP A, and the input channels 3 and 4 to GROUP B. [GROUP A] SIG LED Ducker ontrol NOM ontrol Microphone Trim HPF PEQ() OMP/ Auto-leveler Level Sense Gate Fader GR Trim Auto MIX SIG LED Microphone Trim HPF PEQ() OMP/ Auto-leveler Level Sense Gate Fader GR Trim Auto MIX [GROUP B] SIG LED Ducker ontrol NOM ontrol Microphone 3 Trim HPF PEQ() OMP/ Auto-leveler Level Sense Gate Fader GR Trim Auto MIX SIG LED Microphone 4 Trim HPF PEQ() OMP/ Auto-leveler Level Sense Gate Fader GR Trim Auto MIX 37

38 Gate settings (p. 35) [ I N ] AU T OM I X GROU P A Rotate the Setting knob to select a group from GROUP A to D. Pressing an Input channel selector key permits the auto-mixing group to be set for that channel. The [IN ] indication changes to the selected channel number indication. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed Ducker Settings The ducker function is one of the D-90's auto-mixing functions, and automatically adjusts individual input channel gains in response to input signal level. Refer to the previous page for the block diagram of the Auto- Mixing section. When a received signal exceeds the gate threshold level, the ducker function automatically attenuates all other input signals which are lower than that input channel in priority. This function operates in individual auto-mixing groups (previous page). When any of the following screens is displayed, the ducker function for the displayed channel can be enabled or disabled by means of the function /OFF key. When enabled (), the function /OFF Indicator lights. Note: When an input channel is set to OFF, the ducker function on that channel does not operate. [Screen display operations] Auto-mixing group settings (previous page) Priority order Attenuation Attack time Release time [ I N ] DUK E R PR I OR I TY 8 [ I N ] DUKER DEPTH 0dB [ I N ] DUKER ATTAK 0. 0 m s [ I N ] DUK E R RELEA SE 0. 0m s NOM attenuation /OFF settings (next page) Priority settings [ I N ] DUK E R PR I OR I TY 8 Rotate the Setting knob to set priorities. Parameter setting range: 8 (: Highest priority; 8: Lowest priority) Pressing an Input channel selector key permits ducker priorities to be set for that channel. The [IN ] indication changes to the selected channel number indication. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed Attenuation settings [ I N ] DUK E R DEPTH 0dB Rotate the Setting knob to set an attenuation. Parameter setting range: INF ( ) to 0 db in db steps Pressing an Input channel selector key permits the ducker attenuation to be set for that channel. The [IN ] indication changes to the selected channel number indication.

39 Attack time settings [ I N ] DUK E R A T T A K 0. 0 m s Rotate the Setting knob to set the attack time (the time required for the attenuation to be a set value). Parameter setting range: 0 ms 0 s (Refer to p. 86 for more information.) Pressing an Input channel selector key permits the ducker attack time to be set for that channel. The [IN ] indication changes to the selected channel number indication Release time settings [ I N ] DUK E R RELEASE 0. 0 m s Rotate the Setting knob to set the release time (the time required for the attenuation to reach the original gain of 0 db). Parameter setting range: 0 ms 0 s (Refer to p. 86 for more information.) Pressing an Input channel selector key permits the ducker release time to be set for that channel. The [IN ] indication changes to the selected channel number indication NOM Attenuation /OFF Settings The NOM Attenuation function is one of the D-90's auto-mixing functions, and automatically adjusts individual input channel gains in response to input signal level. Refer to p. 37 for the block diagram of the Auto-Mixing section. NOM is an acronym of Number of Open Microphones, and represents the number of microphones in open status (the number of input channels with open gates). The NOM attenuation function automatically adjusts the open microphone's input channel gain depending on the number of open microphones. The open microphone channel gain is attenuated by the gain set on the Utility setting screen (p. 6) each time the number of open microphones doubles. The use of this function allows an output level to be kept constant, thus helping to prevent feedback. This function operates in individual auto-mixing groups (p. 37). Note: When an input channel is set to OFF, the NOM function on that channel does not operate. Ducker settings (previous page) [ I N ] NOM OFF Press the function /OFF key to enable or disable the NOM attenuation function for individual input channels. Pressing an Input channel selector key enables or disables the NOM attenuation function for that channel. The [IN ] indication changes to the selected channel number indication. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed. Input channel gain settings (next page) 39

40 8.7. Input hannel Gain Settings NOM attenuation /OFF settings (previous page) [ I N ] F AD E R IN FdB Rotate the Setting knob to set the input channel gain. Parameter setting range: INF ( ) to +0 db Press the function /OFF key to enable or disable the channel. Pressing an Input channel selector key permits the gain to be set for that channel. The [IN ] indication changes to the selected channel number indication. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed. Bus assignment settings (next page) or Input channel group trim gain settings (next section) 8.8. Input hannel Group Trim Gain Settings (Only when Group is set) [ I N ] GR - T R I M d B Bus assignment and crosspoint gain settings (next page) The indication at left is displayed only when Group setting is performed. Perform the Group settings on the Utility setting screen (p. 6). Rotate the Setting knob to set the group trim gain (offset gain). Parameter setting range: INF ( ) to +0 db in 0. db steps Pressing an Input channel selector key permits the group trim gain to be set for that channel. The [IN ] indication changes to the selected channel number indication. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed. 40

41 8.9. Bus Assignment and rosspoint Gain Settings [Screen display operations] Input channel gain settings (previous page) or Input channel group trim gain settings (previous page) Bass assignment [ I N ] A S S I GN [OUT] M rosspoint gain [ IN ] GAIN OUT 0 db Bus assignment settings Set input-to-output signal paths. [ I N ] A S S I GN [OUT] M Rotate the Setting knob to select the output channel bus ( 8 or MicB*), then press the function /OFF key to enable or disable the assignment. * Microphone bus : The "M" indication is displayed when enabled. [Setting example] [ I N ] A S S I GN [OUT]3 M Pressing an Input channel selector key permits the bus assignment to be set for that channel. The [IN ] indication changes to the selected channel number indication. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed. Note The bus assignment settings can also be performed using only the input/output channel controls on the front panel. (Example: Input channel Output channels 5 and 8) 7 PEAK +db 8 +6dB dB -6dB db 5 5-0dB SEL 6-40dB 6 SEL SIG 0N 0N SIG SEL 7 FBS 8 0N SIG SEL EFFET Press the desired Output channel selector key(s) while holding down the Input channel selector key. The set output channel's indicator [SEL] lights. Pressing the microphone bus selector key sends the signal from the selected input channel to the microphone bus. INPUT MI BUS OUTPUT Tip The channel is simultaneously assigned to both L and R channels when assigned from "stereo-linked" input channels to "stereo-linked" output channels. (Refer to p. 56 Stereo Link Settings.) [Example] When Inputs and and outputs and are both "stereo-linked," pressing the Input hannel selector key and Output hannel selector key sets the assignment of Input Output and Input Output, causing the Output hannels and indicators [SEL] to light rosspoint gain settings [ I N ] GA I N OUT ] 0 db Rotate the Setting knob to set the crosspoint gain. Parameter setting range: INF ( ) to 0 db in db steps Pressing an Input channel selector key permits the input channel selection. Pressing an Output channel selector key permits the output channel selection. Pressing the function /OFF key enables or disables the selected assignment. 4

42 9. OUTPUT SETTINGS Output channels selected with the Output channel selector keys can be enabled or disabled using the output channel /OFF key. Use the function /OFF key to enable or disable each function displayed on the LD screen. 9.. Output hannel Gain Settings [OUT ] FADER O N 0. 0 d B Filter settings (p. 45), Output channel group trim gain settings (next section), or rossover settings (next page) Rotate the Setting knob to set the output channel gain. Parameter setting range: INF ( ) to +0 db Press the function /OFF key to enable or disable the displayed channel. Pressing an Output channel selector key permits the gain to be set for that channel. The [OUT ] indication changes to the selected channel number indication. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed. 9.. Output hannel Group Trim Gain Settings (Only when Group is set) [OUT] GR-TRIM d B rossover settings (next page) or Filter settings (p. 45) The indication at left is displayed only when Group setting is performed. Perform the Group settings on the Utility setting screen (p. 56). Rotate the Setting knob to set the group trim gain (offset gain). Parameter setting range: INF ( ) to +0 db in 0. db steps Pressing an Output channel selector key permits the group trim gain to be set for that channel. The [OUT ] indication changes to the selected channel number indication. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed. 4

43 9.3. rossover Settings (Only when rossover function is enabled) The following screens are displayed only when the crossover function is enabled on the Utility setting screen. (Refer to p. 6 for more information.) [Screen display operations] Output channel gain settings (previous page) or Output channel group trim gain settings (previous page) (Displayed when parameters other than THRU are selected) (High frequency) (Displayed depending on the type of slope) Slope utoff frequency Q Q [OUT ] XOVER - HF TYPE THRU [OUT ] XOVER - HF FREQ. 00kHz [OUT ] XOVER - HF Q [OUT ] XOVER - HF Q To A A rossover gain [OUT ] XOVER - HF GA I N db rossover filter polarity [OUT ] XOVER - HF POL NORMAL (Displayed when parameters other than THRU are selected) (Displayed depending on the type of slope) (Low frequency) [OUT] XOVER-LF TYPE THRU [OUT] XOVER-LF FREQ. 00kHz [OUT] XOVER-LF Q [OUT] XOVER-LF Q To B B [OUT] XOVER-LF GA I N db [OUT] XOVER-LF POL NORMAL Filter settings (p. 45) Slope settings (High frequency) [ OUT ] XOVER - HF TYPE THRU (Low frequency) [ OUT ] XOVER - LF TYPE THRU Rotate the Setting knob to select the type of slope. Parameter setting range: THRU (through), 6 db (6 db/oct), BS ( db/oct BS), etc. (Refer to p. 87 for more information.) Notes () Slope type: BS (Bessel), BW (Butterworth), LR (Linkwitz- Riley), VQ (Variable Q) () Displayed slope type differs depending on the rossover configuration setting. (Refer to p. 6.) Using the shift key, the display is moved to the rossover Gain setting screen if THRU is selected, and to the utoff Frequency setting screen if parameters other than THRU are set. Pressing an Output channel selector key permits the crossover filter to be set for that channel. The [OUT ] indication changes to the selected channel number indication. 43

44 9.3.. utoff frequency settings (High frequency) [ OUT ] XOVER - HF F R EQ. 0 0 k H z (Low frequency) [ OUT ] XOVER - LF F R EQ. 0 0 k H z Rotate the Setting knob to set the cutoff frequency. Parameter setting range: 0 Hz 0 khz in /4 octave steps Pressing an Output channel selector key permits the crossover filter to be set for that channel. The [OUT ] indication changes to the selected channel number indication Q settings (High frequency) [ OUT ] XOVER - HF Q (Low frequency) [ OUT ] XOVER - LF Q The Q setting can be performed only when the type of slope is VQ. Rotate the Setting knob to set the Q. Parameter setting range: (5 points) Pressing an Output channel selector key permits the crossover filter to be set for that channel. The [OUT ] indication changes to the selected channel number indication Q settings (High frequency) [ OUT ] XOVER - HF Q (Low frequency) [ OUT ] XOVER - LF Q The Q setting can be performed only when the type of slope is 4VQ. Rotate the Setting knob to set the Q. Parameter setting range: (5 points) Pressing an Output channel selector key permits the crossover filter to be set for that channel. The [OUT ] indication changes to the selected channel number indication rossover gain settings (High frequency) [ OUT ] XOVER - HF GAIN +0.0dB (Low frequency) [ OUT ] XOVER - LF GAIN +0.0dB Rotate the Setting knob to set the crossover gain. Parameter setting range: 5 to +5 db in 0. db steps Pressing an Output channel selector key permits the crossover filter to be set for that channel. The [OUT ] indication changes to the selected channel number indication rossover filter polarity settings (High frequency) [ OUT ] XOVER - HF POL NORMAL (Low frequency) [ OUT ] XOVER - LF POL NORMAL Rotate the Setting knob to set the crossover filter polarity. Parameter setting range: NORMAL and INVERSE Pressing an Output channel selector key permits the crossover filter to be set for that channel. The [OUT ] indication changes to the selected channel number indication. 44

45 9.4. Filter Settings When any of the following screens is displayed, the filter function for the displayed channel can be enabled or disabled by pressing the function /OFF key. When enabled (), the function /OFF Indicator lights. [Screen display operations] Output channel gain settings (p. 4), Output channel group trim gain settings (p. 4), or rossover settings (p. 43) Filter settings (Type selection) [ OU T ] F I L T E R TYPE THRU Parametric equalizer [OUT] TYPE FILTER PEQ Gain [ OU T ] F I L T E R GAIN +0.0dB enter frequency [ OU T ] F I L T E R FREQ. 00kHz Q [ OU T ] F I L T E R Q High-pass filter (6 db) [ OU T ] F I L T E R TYPE HPF - 6dB utoff frequency [OUT] FILTER FREQ. 00kHz High-pass filter ( db) [ OU T ] F I L T E R TYPE HPF - db utoff frequency [OUT] FILTER FREQ. 00kHz Q [ OU T ] F I L T E R Q Low-pass filter (6 db) [ OU T ] F I L T E R TYPE LPF - 6dB utoff frequency [OUT] FILTER FREQ. 00kHz Low-pass filter ( db) [ OU T ] F I L T E R TYPE LPF - db utoff frequency [OUT] FILTER FREQ. 00kHz Q [ OU T ] F I L T E R Q High shelving filter [ OU T ] F I L T E R TYPE H - She l v Gain [ OU T ] F I L T E R GAIN +0.0dB Roll-off frequency [ OU T ] F I L T E R FREQ 6. 00kHz Low shelving filter [ OU T ] F I L T E R TYPE L - She l v Gain [ OU T ] F I L T E R GAIN +0.0dB Roll-off frequency [ OU T ] F I L T E R FREQ 6. 00kHz Horn equalizer [ OU T ] F I L T E R TYPE HORN EQ Gain [ OU T ] F I L T E R GAIN +0.0dB Notch filter [ OU T ] F I L T E R TYPE NOTH enter frequency [OUT] FILTER FREQ. 00kHz Q [ OU T ] F I L T E R Q All-pass filter [ OU T ] F I L T E R TYPE ALL PASS enter frequency [OUT] FILTER FREQ. 00kHz Q [ OU T ] F I L T E R Q * The number of displayed filters differs Filter 6* settings (Type selection) depending on the crossover configuration settings on the Utility setting screen. (Refer to p. 6.) Tip ompressor settings (p. 50) Filters range from to 6 in number, and the setting items for each filter are the same. Press the and shift keys to change the filter number. 45

46 [Setting procedures (Example of setting output filter as a horn equalizer)] [ OU T ] F I L T E R TYPE THRU [ OU T ] F I L T E R TYPE THRU 3 [ OU T ] F I L T E R TYPE HORN EQ [OUT] GA I N FILTER db 4 [OUT] GA I N FILTER db Step. Press the shift key to display a filter. Step. Rotate the Setting knob to select the type of filter. Step 3. Press the shift key to display the setting items for the selected filter. Step 4. Rotate the Setting knob to set the parameters for each item. Step 5. Repeat Steps 3 and 4 when there are two or more setting items. 46

47 9.4.. Parametric equalizer [ OU T ] F I L T E R TYPE PEQ Rotate the Setting knob to select PEQ and enter the Parametric Equalizer setting screen. Pressing an Output channel selector key permits the filter to be set for that channel. The [OUT ] indication changes to the selected channel number indication. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed. [Gain settings] [ OU T ] F I L T E R GAIN +0.0dB Rotate the Setting knob to set the gain. Parameter setting range: 5 to +5 db in 0. db steps Pressing an Output channel selector key permits the filter to be set for that channel. The [OUT ] indication changes to the selected channel number indication. [enter frequency settings] [ OU T ] F I L T E R FREQ. 00kHz Rotate the Setting knob to set the center frequency. Parameter setting range: 0 Hz 0 khz in /4 octave steps Pressing an Output channel selector key permits the filter to be set for that channel. The [OUT ] indication changes to the selected channel number indication. [Q settings] [ OU T ] F I L T E R Q Rotate the Setting knob to set the Q. Parameter setting range: (96 points) Pressing an Output channel selector key permits the filter to be set for that channel. The [OUT ] indication changes to the selected channel number indication High-pass filter [ OU T ] F I L T E R TYPE HPF - 6dB Rotate the Setting knob to select either HPF-6 db or HPF- db and enter the High-Pass Filter setting screen. The indications of 6 db and db represent the slope: 6 db/oct and db/oct, respectively. Pressing an Output channel selector key permits the filter to be set for that channel. The [OUT ] indication changes to the selected channel number indication. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed. [utoff frequency settings] [ OU T ] F I L T E R FREQ. 00kHz Rotate the Setting knob to set the cutoff frequency. Parameter setting range: 0 Hz 0 khz in /4 octave steps Pressing an Output channel selector key permits the filter to be set for that channel. The [OUT ] indication changes to the selected channel number indication. 47

48 [Q settings] [ OU T ] F I L T E R Q The Q setting can only be performed when HPF- db is selected. Rotate the Setting knob to set the Q. Parameter setting range: (5 points) Pressing an Output channel selector key permits the filter to be set for that channel. The [OUT ] indication changes to the selected channel number indication Low-pass filter [ OU T ] F I L T E R TYPE LPF - 6dB Rotate the Setting knob to select either LPF-6 db or LPF- db, and enter the Low-Pass Filter setting screen. The indications of 6 db and db represent the slope: 6 db/oct and db/oct, respectively. Setting items, parameter setting ranges and operations are the same as those for the high-pass filter High shelving filter [ OU T ] F I L T E R TYPE H - She l v Rotate the Setting knob to select H-Shelv and enter the High Shelving Filter setting screen. Pressing an Output channel selector key permits the filter to be set for that channel. The [OUT ] indication changes to the selected channel number indication. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed. [Gain settings] [ OU T ] F I L T E R GAIN +0.0dB Rotate the Setting knob to set the gain. Parameter setting range: 5 to +5 db in 0. db steps Pressing an Output channel selector key permits the filter to be set for that channel. The [OUT ] indication changes to the selected channel number indication. [Roll-off frequency settings] [ OU T ] F I L T E R FREQ 6. 00kHz Rotate the Setting knob to set the roll-off frequency. Parameter setting range: 6 0 khz in /4 octave steps Pressing an Output channel selector key permits the filter to be set for that channel. The [OUT ] indication changes to the selected channel number indication Low shelving filter [ OU T ] F I L T E R TYPE L - She l v Rotate the Setting knob to select L-Shelv and enter the Low Shelving Filter setting screen. Setting items and operations are the same as those for the high shelving filter. Parameter setting range Gain: 5 to +5 db in 0. db steps Roll-off frequency: Hz in /4 octave steps

49 Horn equalizer [ OU T ] F I L T E R TYPE HORN EQ Rotate the Setting knob to select HORN EQ and enter the Horn Equalizer setting screen. Pressing an Output channel selector key permits the filter to be set for that channel. The [OUT ] indication changes to the selected channel number indication. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed. [Gain settings] [ OU T ] F I L T E R GAIN +0.0dB Rotate the Setting knob to set the gain. Parameter setting range: 0 to +8 db in 0.5 db steps Pressing an Output channel selector key permits the filter to be set for that channel. The [OUT ] indication changes to the selected channel number indication Notch filter [ OU T ] F I L T E R TYPE NOTH Rotate the Setting knob to select NOTH and enter the Notch Filter setting screen. Pressing an Output channel selector key permits the filter to be set for that channel. The [OUT ] indication changes to the selected channel number indication. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed. [enter frequency settings] [ OU T ] F I L T E R FREQ. 00kHz Rotate the Setting knob to set the center frequency. Parameter setting range: 0 Hz 0 khz in /4 octave steps Pressing an Output channel selector key permits the filter to be set for that channel. The [OUT ] indication changes to the selected channel number indication. [Q settings] [ OU T ] F I L T E R Q Rotate the Setting knob to set the Q. Parameter setting range: (Refer to p. 87 for more information.) Pressing an Output channel selector key permits the filter to be set for that channel. The [OUT ] indication changes to the selected channel number indication All-pass filter [ OU T ] F I L T E R TYPE ALL PASS Rotate the Setting knob to select ALL PASS and enter the All- Pass Filter setting screen. Pressing an Output channel selector key permits the filter to be set for that channel. The [OUT ] indication changes to the selected channel number indication. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed. 49

50 [enter frequency settings] [ OU T ] F I L T E R FREQ. 00kHz Rotate the Setting knob to set the center frequency. Parameter setting range: 0 Hz 0 khz in /4 octave steps Pressing an Output channel selector key permits the filter to be set for that channel. The [OUT ] indication changes to the selected channel number indication. [Q settings] [ OU T ] F I L T E R Q Rotate the Setting knob to set the Q. Parameter setting range: (96 points) Pressing an Output channel selector key permits the filter to be set for that channel. The [OUT ] indication changes to the selected channel number indication ompressor Settings When any of the following screens is displayed, the compression function for the displayed channel can be enabled or disabled with the function /OFF key. When enabled (), the function /OFF Indicator lights. [Screen display operations] Filter settings (P. 45) Threshold level Ratio Attack time Release time Makeup gain [ OUT ] OMP THRESH +0dB [OUT] OMP RATIO : [OUT] OMP ATTAK 0. 0m s [OUT] OMP RELEAS E 5 0 0m s [OUT] OMP GA I N + 0 db Delay time settings (next page) Threshold level settings [ OUT ] OMP THRESH +0dB Rotate the Setting knob to set the threshold level. Parameter setting range: 0 to +0 db in db steps Pressing an Output channel selector key permits the compressor threshold level to be set for that channel. The [OUT ] indication changes to the selected channel number indication. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed Ratio settings [ OUT ] OMP RATIO : Rotate the Setting knob to set the ratio. Parameter setting range: :, :, 3:, 4:, 8:, :, 0:, INF ( ): Pressing an Output channel selector key permits the compression ratio to be set for that channel. The [OUT ] indication changes to the selected channel number indication. 50

51 Attack time settings [OUT] OMP ATTAK 0. 0m s Rotate the Setting knob to set the attack time. Parameter setting range: 0. ms 5 s (Refer to p. 85 for more information.) Pressing an Output channel selector key permits the compressor attack time to be set for that channel. The [OUT ] indication changes to the selected channel number indication Release time settings [ OUT ] OMP RELEAS E 500m s Rotate the Setting knob to set the release time. Parameter setting range: 0 ms 5 s (Refer to p. 85 for more information.) Pressing an Output channel selector key permits the compressor release time to be set for that channel. The [OUT ] indication changes to the selected channel number indication Makeup gain settings [ OUT ] OMP GAIN +0dB Rotate the Setting knob to set the makeup gain. Parameter setting range: INF ( ) to +0 db in db steps. Pressing an Output channel selector key permits the compression makeup gain to be set for that channel. The [OUT ] indication changes to the selected channel number indication Delay Time Settings ompressor settings (previous page) [OUT ] DELAY OFF m s Rotate the Setting knob to set the delay time. Parameter setting range: ms in 0.0 ms steps Press the function /OFF key to enable or disable the delay function. Pressing an Output channel selector key permits the delay time to be set for that channel. The [OUT ] indication changes to the selected channel number indication. The setting screen reverts to the Input/Output Gain Setting screen when the shift key is pressed. 5

52 0. MIROPHE BUS SETTINGS SEL The Microphone Bus setting screen is displayed when the Microphone Bus selector key is pressed. 0.. Feedback Suppression Settings [Suppressing acoustic feedback with a simple operation] Step. Set the volume controls of connected external equipment to the state in which they will actually be used. Step. Activate the Auto mode on the Feedback Suppression setting screen. (Refer to the next page.) All filters ( bands) that suppress feedback are set after they are initialized. Notes Auto mode cannot be initiated if the number of Auto mode filters is set to 0. (Refer to the next page.) Large sounds are produced during Auto mode operation. Setting takes about.5 minutes. (This may differ depending on the unit installation circumstances.) No keys can be used during Auto mode operation. Press the Setting knob to interrupt setup operations. [Settings to be performed as required] Step 3. Set the Dynamic mode or the number of filters on the Feedback Suppression setting screen, or perform individual settings on the Feedback Suppression Filter setting screen as required. Notes When the number of filters to be used for the Auto and Dynamic modes have been changed, reactivate the Auto mode. Take care when executing filter initialization, as feedback may occur. It is recommended that the Auto mode be reset when the equalizer setting value has been changed, because the feedback points may change. [Screen display operations] Dynamic mode [Mi cb] FBS DYNAM I OFF Auto mode activation Filters number Dynamic mode filter initialization Auto mode filter initialization [Mi cb] FBS AUTO START OK? [Mi cb] FBS AUTO : DYN 7 : 5 [Mi cb] FBS LEAR DYN OK? [Mi cb] FBS LEAR AUTO OK? Feedback suppression filter setting confirmation (p. 54) 0... Dynamic mode settings [Mi cb] FBS DYNAM I OFF Press the function /OFF key to enable or disable the feedback suppression function. Enabling the function permits feedback to be suppressed in real time as it occurs. (Dynamic mode) 5

53 0... Auto mode activation [Mi cb] FBS AUTO START OK? Press the Setting knob to automatically search for the feedback points and set the filters for feedback suppression. (Auto mode) Both the FBS (Feedback suppression) and the LOK (System lock) indicators flash during Auto mode operation. To interrupt the Auto mode operation, press the Setting knob. When the number of filters is set to "0" for Auto mode, the indication "an't use Auto" is displayed on the LD screen, disabling the Auto mode activation. To cancel the function, press the or shift key, and the screen changes to display the previous or next setting item Filter number settings [Mi cb] FBS AUTO : DYN 7 : 5 Rotate the Setting knob to set the number of filters to be used for Auto and Dynamic modes. Filters are assigned to both modes from filters in total. Filters used for Auto and Dynamic modes are assigned to Auto mode followed by Dynamic mode in order of filter number as shown below. [Example for "AUTO : DYN 7 : 5" (default setting)] Filter No Mode Auto mode Dynamic mode [Example for "AUTO : DYN 8 : 4"] Filter No Mode Auto mode Dynamic mode Even when the number of filters is changed, filters are not initialized. For example, when filter assignment is changed from "AUTO : DYN 7 : 5" to "AUTO : DYN 8 : 4" (refer to the above setting examples), Filter 8 operation mode is switched to Auto mode, however, keeping the filter parameters once set by Dynamic mode operation. The Filter parameters and Mode confirmation display (next page) remain unchanged as those for Dynamic mode till Auto mode is activated Dynamic mode filter initialization [Mi cb] FBS LEAR DYN OK? All filters set for the Dynamic mode are initialized when the Setting knob is pressed. To cancel the function, press the or shift key, and the screen changes to display the previous or next setting item Auto mode filter initialization [Mi cb] FBS LEAR AUTO OK? All filters set for the Auto mode are initialized when the Setting knob is pressed. To cancel the function, press the shift key, and the screen returns to display the previous setting item. 53

54 0.. Feedback Suppression Filter Setting onfirmation The settings of all Dynamic and Auto mode feedback suppression filters can be quickly confirmed. [Screen display operations] Feedback suppression settings (p. 5) Filter mode confirmation [ M i c B ] F I L T E R TYPE AUTO Frequency confirmation [Mi cb] F I LTER FREQ 0. 0kHz Filter gain confirmation [Mi cb] F I LTER GA I N db Q confirmation [Mi cb] F I LTER Q Tip Filter mode confirmation Feedback suppression filters range from to in number, and the setting items for each filter are the same. Press the and shift keys to change the filter number. Effect (echo) settings (next page) 0... Mode confirmation [ M i c B ] F I L T E R TYPE AUTO The DYN indication is displayed for filters set by the Dynamic mode operation, while the AUTO indication is displayed for filters set by the Auto mode operation, and the "----" indication for filters that are not set Frequency confirmation [ M i c B ] F I L T E R F R EQ 0. 0 k H z Set filter frequencies can be confirmed Filter gain confirmation [ M i c B ] F I L T E R GAIN +0.0dB Set filter gains can be confirmed Q confirmation [ M i c B ] F I L T E R Q Set filter Q can be confirmed. 54

55 0.3. Effect (Echo) Settings The D-90 has an echo function, a part of an effect function. EFFET The Effect (echo) setting screen can be displayed by pressing the Effect key, or by using the Screen shift keys on the Microphone Bus setting screen. The effect (echo) function can be enabled or disabled with the function /OFF key or Effect key when any of the following screens is displayed. The function /OFF and Effect indicators light when enabled (). [Screen display operations] Feedback suppression filter setting confirmation (previous page) Echo gain Feedback ratio Feedback delay Initial echo delay Low-pass filter frequency Low-pass filter Q [Mi cb] EHO OUTGAIN 0dB [Mi cb] EHO FB RAT I O 30% [Mi cb] EHO FB DLY 0m s [Mi cb] EHO Pr edly 80m s [Mi cb] EHO LPF - F 3. 75kH z [Mi cb] EHO LPF -Q Bus assignment and crosspoint gain settings (next page) [Effect (echo) function block diagram] To feedback suppression Pre-delay LPF Echo gain Feedback delay Feedback ratio Echo gain settings [Mi cb] EHO OUTGAIN 0dB Rotate the Setting knob to set the echo gain. Parameter setting range: INF ( ) to 0.0 db in db steps Feedback ratio settings [Mi cb] EHO FB RAT I O 30% Rotate the Setting knob to set the feedback ratio. Parameter setting range: 0 99% in % steps Feedback delay settings [Mi cb] EHO FB DLY 0m s Rotate the Setting knob to set the feedback delay time. Parameter setting range: 0 68 ms 55

56 Initial echo (pre-) delay settings [Mi cb] EHO Pr edly 80m s Rotate the Setting knob to set the initial echo delay time. Parameter setting range: 0 68 ms Low-pass filter frequency settings [Mi cb] EHO LPF-F 3.75k H z Rotate the Setting knob to set the low-pass filter frequency. Parameter setting range: 0 Hz 0 khz Low-pass filter Q settings [Mi cb] EHO L P F - Q Rotate the Setting knob to set the low-pass filter Q. Parameter setting range: (5 points) 0.4. Bus Assignment and rosspoint Gain Settings (Microphone Bus Output hannel) [Screen display operations] Effect (echo) settings (previous page) Bus assignment [Mi cb] ASSIGN [OUT] rosspoint gain [Mi cb] GAIN OUT 0 db Bus assignment settings [Mi cb] ASSIGN [OUT] Rotate the Setting knob to select the output channel bus ( 8), then press the function /OFF key to enable or disable the assignment. When disabled (OFF), the " " indication is displayed. All buses 8 are enabled by default rosspoint gain settings [ I N ] GA I N OUT ] 0 db Rotate the Setting knob to set the crosspoint gain. Parameter setting range: INF ( ) to 0 db in db steps Pressing an Input channel selector key permits the input channel selection. Pressing an Output channel selector key permits the Output channel selection. Pressing the function /OFF key enables or disables the selected assignment. 56

57 . PRESET MEMORY SETTINGS PRESET The preset setting screen is displayed when the Preset key is pressed. Pressing the key again exits the preset setting screen in any of the following settings, displaying the Input/Output Gain Setting screen... Preset Memory Save Set parameters can be stored in memory (number of memories: 6). [Parameters that can be stored in memory] Input channel parameters: PAD, Phantom power, Line input mode selection, Line input selection, Input trim gain, Input trim polarity, High-pass filter, Equalizer (low and high frequencies), ompressor/auto-leveler mode selection, ompressor/auto-leveler, Level sense, Gate, Auto-mixing group, Ducker, NOM attenuation /OFF, Input channel gain, hannel /OFF, Group trim gain, and Bus assignment Output channel parameters: Output channel gain, Group trim gain, hannel /OFF, Filters 6 (including crossover), ompressor, and Delay Microphone bus parameters: Feedback suppression (Dynamic mode /OFF, Filter number, and Filter parameters set in Auto and Dynamic modes), Echo, and Bus assignment Others: Stereo link, Group, rossover configuration, NOM attenuation, and hannel selection status [ PRESET ] SAVE No. OK? Step. Press the and shift keys to select the desired preset memory number. Preset memory number selection [ PRESET ] SAVE No. OK? Preset memory number selection [ PRESET ] SAVE No. OK? Preset memory number 6 selection [PRESET] SAVE No. 6 OK? Step. Press the Setting knob to execute the function. The indication "Now Saving..." is displayed and saving begins. Saving is completed when the indication turns off. Preset memory recall (next page) [ PRESET ] Now Sa vi ng... Note: To cancel the function, press the Preset key. 57

58 .. Preset Memory Recall Recall the stored preset memory. Preset memory save (previous page) [ PRESET ] LOAD No. OK? Step. Press the and shift keys to select the desired preset memory number. Preset memory number selection [ PRESET ] LOAD No. OK? Preset memory number selection [ PRESET ] LOAD No. OK? Preset memory number 6 selection [ PRESET ] LOAD No. 6 OK? Tip The screen at left can be recalled for preset memory numbers 8 by simply pressing the desired Preset Memory selector key, regardless of the currently displayed setting screen. However, the display cannot be switched to another screen by way of the and keys. Step. Press the Setting knob to execute the function. The indication "Now Loading..." is displayed and loading begins. Recall is completed when the indication turns off. [ PRESET ] N o w L o ad i n g... Note: To cancel the function, press the Preset key..3. Preset Memory Delete Delete the stored preset memory. [ PRESET ] DELETE No. OK? Preset memory crossfade time settings (next page) Step. Press the and shift keys to select the preset memory number to be deleted. Preset memory number selection [ PRESET ] DELETE N 0. OK? Preset memory number selection [ PRESET ] DELETE No. OK? Preset memory number 6 selection [ PRESET ] DELETE No. 6 OK? Step. Press the Setting knob to execute the function. The indication "Now Deleting..." is displayed and deletion begins. Deletion is completed when the indication turns off. [ PRESET ] Now De let ing... Note: To cancel the function, press the Preset key. 58

59 .4. Preset Memory rossfade Time Settings Set the crossfade time when the currently selected preset memory is switched over to a newly recalled one by pressing the preset memory number. [Parameters to be cross-faded] Input/output channel gains, channel /OFF, bus assignment, cross-point gains. Parameters other than those above instantaneously switch when the preset memory is recalled. Note When the currently selected preset memory is switched over to a newly recalled one, the channels of which phantom power /OFF, PAD, line input mode, and line input selection have been changed are muted for a specified period of time. Preset memory delete (previous page) [Setting example] [ PRESET ] FADE [ PRESET ] FADE [ PRESET ] FADE ALL No. 0. 0sec No. 0. 0sec N o s e c Initial preset memory selection (next page) [ PRESET ] FADE No. 3. 5sec 3 Step. Press the and shift keys to select the desired preset memory number. Note On the [All No.] screen, crossfade time of all memories can be set at a time. The following screen appears when each memory setting is different. [ PRESET ] FADE ALL No. ----sec Step. Rotate the Setting knob to change the crossfade time. Parameter setting range: s, 0.5 s steps Tips Saving the configuration (see the next page) causes the parameters to be cross-faded to change at the set crossfade time. onfiguration can also be saved by pressing the Setting knob on this screen. To cancel the function, press the Preset key. 59

60 .5. Initial Preset Memory Selection Select the preset memory number ( 6) or LAST MEMORY to be automatically recalled when the power is switched on. Preset memory crossfade time settings (previous page) LAST MEMORY selection [ PRESET ] START LAST MEMORY Preset memory number selection [PRESET] START No. Preset memory number 6 selection [PRESET] START No. 6 onfiguration Save (next section) [ PRESET ] START LAST MEMORY Press the and shift keys to select the desired preset memory number to be automatically recalled when the power is switched on. Setting the LAST MEMORY permits the preset memory number recalled last before the unit's power-off to be automatically recalled at the power-on. Note The preset memory is set to LAST MEMORY by default, and the preset memory No. is recalled. Performing the onfiguration Save (next item) allows the selected memory number to be saved as a preset memory number recalled at unit's power-on operation. Be sure to perform the onfiguration Save after changing the preset number selection. The onfiguration save can also be executed by pressing the Setting knob at this screen. To cancel the function, press the Preset key..6. onfiguration Save Preset memory crossfade time setteings (previous section) [ F I G ] SAVE OK? Pressing the Setting knob saves the settings for the Preset Memory rossfade Time, the ontact Input/Output functions, Protect function, and Initial preset memory. To cancel the function, press the Preset key. 60

61 . UTILITY SETTINGS UTILITY The utility setting screen is displayed when the Utility key is pressed... Stereo Link Settings [UTY] STR LINK [ I N ] [ I N ] Rotate the Setting knob to select the channels to be "Stereo- Linked." Press the function /OFF key to enable or disable the Stereo- Link setting. [Setting example] [UTY] STR LINK [ I N ] = [ I N ] Note The output channel that is enabled for crossover function - a parameter except "NE" is set - in the rossover onfiguration Settings (p. 6) is displayed on the screen as follows, not being set as a "Stereo-Linked" channel. [UTY] STR LINK [OUT ]x [OUT ].. Group Settings Stereo Link setting (above item) By grouping multiple channels together, the gains of these channels can be simultaneously adjusted using the Input or Output volume control. [ UTY ] GROUP I NG The following "Stereo-Linked" channel parameter settings are synchronized: Input channel: [ I N ] PAD, Phantom power, Input trim gain, High-pass filter, Parametric equalizer, ompressor/autoleveler*, Gate*, Auto-mixing group, Ducker, NOM attenuation /OFF, Input channel gain, hannel /OFF, and Group settings Output channel: Output channel gain, Filters 6 (including crossover), ompressor*, Delay, and Group settings * Operations are also synchronized. Tip When the input channel and the output channel are both set for Stereo Link, the bus assignment setting is also synchronized. (Refer to p. 4.) Step. Rotate the Setting knob to display the channels to be grouped in the [ ] area on the lower row. Step. Press the shift key. [ UTY ] GROUP I NG [ I N 3 ] [ I N 3 ] 3 IN ] 4 3 [ UTY ] GROUP I NG [ I N 3 ] 34 [ I N 3 ] 3 4 IN 4] rossover configuration (high frequency) settings (next page) 6

62 Step 3. Rotate the Setting knob to select the channels to be grouped together with the channels displayed in the [ ] area on the upper row. (The selected channels are displayed in the " ]" area on the lower row. Step 4. Press the function /OFF key to confirm the selected channels. All of the channels set for grouping are displayed on the upper row at the right. Note When group settings are performed, the offset gain between the channels in the [ ] area on the upper row and the selected channels are set as the selected channels' group trim value. Therefore, after grouping, the fader gain is the same if the channels grouped together are within the same group. Tip The channels set for grouping are displayed on the lower row at the right when the shift key is pressed to revert to the initial Group setting screen..3. rossover onfiguration Settings Enable or disable the rossover function. When enabling, set the crossover filter's maximum slope as well. When enabled, the rossover setting screen is displayed on the Output setting screen, depending on setting contents. (Refer to p. 43.) Also, the number of filters to be displayed on the Filter setting screen (p. 45) used in the output settings changes depending on the setting contents. Note The "Stereo-Linked" (p. 6) output channel will not use the crossover function. That output channel is displayed on the screen as shown at right, being made invalid for the crossover configuration setting. Group settings (previous page) (High frequency) [ UTY ] XOVER HF [OUT] NE [ UTY ] XOVER HF [OUT8] NE [UTY] XOVER HF [OUT] NE 3 [UTY] XOVER HF [OUT] HPF 3 (High frequency) [ UTY ] XOVER HF [OUT] (Low frequency) [ UTY ] XOVER LF [OUT] The crossover function (high frequency) is disabled. The rossover setting screen is not displayed. The crossover function (high frequency) is used as a high-pass filter. A slope of up to db/oct can be set. The rossover setting screen is displayed. (A slope of up to db/oct is displayed.) rossover configuration (low frequency) settings (next page) [UTY] XOVER HF [OUT] HPF4 Step. Rotate the Setting knob to display the channel to be set in the [ ] area on the lower row. Step. Press the shift key. The crossover function (high frequency) is used as a high-pass filter. A slope of up to 4 db/oct can be set. The rossover setting screen is displayed. (A slope of up to 4 db/oct is displayed.) 6 Step 3. Rotate the Setting knob to enable or disable the crossover function.

63 rossover configuration (high frequency) settings (previous page) (Low frequency) [ UTY ] XOVER LF [OUT] NE [UTY] [OUT] XOVER LF NE The crossover function (low frequency) is disabled. The rossover setting screen is not displayed. [ UTY ] XOVER LF [OUT8] NE [UTY] [OUT] XOVER LF LPF The crossover function (low frequency) is used as a low-pass filter. A slope of up to db/oct can be set. The rossover setting screen is displayed. (A slope of up to db/oct is displayed.) NOM attenuation settings (next page) [UTY] XOVER LF [OUT] LPF4 Note The setting method is the same as that used for the crossover configuration (high frequency). The crossover function (low frequency) is used as a low-pass filter. A slope of up to 4 db/oct can be set. The rossover setting screen is displayed. (A slope of up to 4 db/oct is displayed.) Number of filters usable for the Filter settings The settings above determine the number of filters to be displayed on the Filter setting screen (p. 45) as follows: XOVER-L Setting XOVER-H Setting NE HPF HPF4 NE LPF LPF

64 .4. NOM Attenuation Settings NOM is an acronym of Number of Open Microphones, and represents the number of microphones in open status (the number of input channels with open gates). The NOM attenuation function automatically adjusts the open microphone's input channel gain depending on the number of open microphones. The open microphone channel gain is attenuated by the gain set on the following setting screen each time the number of open microphones doubles. The use of this function allows an output level to be kept constant, thus helping to prevent feedback. Set each input channel to enable or disable this function. (Refer to p. 39.) This function operates in each of the auto-mixing groups, GROUP A through D (p. 37). [Screen display operations] rossover configuration (low frequency) settings (previous page) GROUP A attenuation gain GROUP B attenuation gain GROUP attenuation gain GROUP D attenuation gain [UTY ] NOM ATTEN [GROUP A] 0 [UTY] NOM ATTEN [ GROUP B ] 0 [UTY] NOM ATTEN [ GROUP ] 0 [UTY ] NOM ATTEN [GROUP D] 0 When using the D-98, D-983, or D-984V: ontact input/output settings (next page) When not using the D-98, D-983, or D-984V: Protect settings (p. 68) [UTY ] NOM ATTEN [ GROUP A ] 0 Rotate the Setting knob to set the attenuation gain for each group. Parameter setting range: 0 0 (0 log0nom 0 log0nom) 64

65 .5. ontact Input/Output Settings (Available only when D-98, D-983, or D-984V is used) Many different functions assigned to the input and output contacts of the D-98 or D-983 Remote ontrol Module, or the D-984V VA ontrol Module can be remotely controlled by connected external equipment. Use the Setting knob to select the functions to be assigned. Notes To make subsequent settings valid when the power is after the initial ontact input/output settings, save the configuration (p. 60). Settings are saved as system data, and setting status is maintained even if the preset memory is recalled. onfiguration can also be saved by pressing the Setting knob at this screen..5.. Function assignment to the input contact Each of the following functions can be assigned to input contacts ( 8 when the D-98 or D-984V is used, and 4 when the D-983 is used). Preset memory recall, Input and output channel volume adjustment, hannel /OFF setting, and Line (stereo) input selection [Screen display operations] NOM attenuation settings (previous page) Input contact number selection [UTY] RM IN : N E [UTY] RM IN : N E No function is assigned. Preset memory recall [UTY] RM IN P R E S E T Preset number [UTY] RM IN : P R E S E T Select the preset memory number. Volume UP [UTY] RM IN VO L U P I N hannel number [UTY] RM IN : VO L U P I N Select the channel number. Volume DOWN [UTY] RM IN VO L DOW N I N hannel number [UTY] RM IN : VO L DOW N I N Select the channel number. [UTY] RM IN : N E [UTY] RM IN 8 : N E hannel /OFF (ontact) hannel /OFF (Pulse) Line (stereo) input selection [UTY] RM IN H MAK E I N [UTY] RM IN H P L S I N [UTY] RM IN L i n e S e l S hannel number [UTY] RM IN : H MAK E I N hannel number [UTY] RM IN : H P L S I N Slot number/line (stereo) input number [UTY] RM IN : L i nese l S Setting items are the same as above. Setting items are the same as above. hannels are enabled when the contact closes, and disabled when the contact opens. Enables and disables channels each time a pulse signal is received. Select the slot number and Line (stereo) input number for the D- 936R or the D-937SP (only when the D-936R or the D-937SP is used). (Example. S-: First line (stereo) input for the stereo module inserted into Slot ) Output contact number selection (p. 67) 65

66 [Setting Procedures (Example. Assigning Preset Memory 3 recall to ontact Input )] [UTY] RM IN : NE [UTY] RM IN : NE [UTY] RM IN N E [UTY] RM IN PRESET 3 4 [UTY] RM IN : PRESET 5 [UTY] RM IN : P R E S E T 3 Step. Rotate the Setting knob to select the input contact number. Step. Press the shift key. Step 3. Rotate the Setting knob to select the function to be assigned to the contact input. Step 4. Press the shift key. Step 5. Rotate the Setting knob to select the setting contents for each function. Tip Pressing the Setting knob executes the onfiguration save and allows the display to revert to the Input contact number selection screen. 66

67 .5.. Function assignment to the output contact The following functions can be assigned to output contacts ( 8 when the D-98 or D984-V is used, and 6 when the D-983 is used). Preset memory recall tally, hannel /OFF tally, ontact input status tally, and Line (stereo) input selection tally The procedures for assigning functions are the same as those used when assigning functions to the input contacts. [Screen display operations] Input contact number selection (p. 65) Output contact number selection [UTY] RM OUT : BR E AK Normally break [UTY] RM OUT BR E AK Set to [Normally break]*. Normally make [UTY] RM OUT MAK E Set to [Normally make]*. Preset memory recall tally [UTY] RM OUT PRESET Preset memory number [UTY] RM OUT : PRESET Select the preset memory number. hannel /OFF tally [UTY] RM OUT H I N hannel number [UTY] RM OUT : H I N Select the channel number. [UTY] RM IN : N E ontact input status tally Line (stereo) input selection tally [UTY] RM OUT RM I N [UTY] RM OUT L i n e S e l S ontact input number [UTY] RM OUT : RM I N [UTY] RM OUT : L i n e S e l S Setting items are the same as above. Slot number/line (stereo) input number Select the contact input number. Select the slot number and line (stereo) input number for the D- 936R or the D-937SP (only when the D-936R or the D-937SP is used). (Example. S-: First line (stereo) input for the stereo module inserted into Slot ) [UTY] RM IN 8 : N E Setting items are the same as above. Protect settings (next page) * Normally break: Turning on the power sets the contact output to "break." Normally make: Turning on the power sets the contact output to "make." Note: All contact outputs are at break while the power is off. 67

68 .6. Protect Settings Operation misses can be avoided by protecting front panel-mounted key operations. Tips To make subsequent protections valid when the power is after the initial Protect function settings, save the configuration (p. 60). (However, if the Protection function is enabled in the way described below, the configuration save needs not be performed because the latest configuration including the Protection function settings are automatically saved at the moment of the key operation.) Settings are saved as system data, and setting status is maintained even if the preset memory is recalled. ontrol operations can be performed either by way of the RS-3 port or the remote control module even when in protection mode. onfiguration can also be saved by pressing the Setting knob at this screen. When using the D-98, D-983, or D-984V: ontact input/output settings (p. 65) When not using the D-98, D-983, or D-984V: NOM attenuation settings (p. 64) [UTY ] PROTET UNLOK Individual Function Key Protect setting screen RS-3 port settings (p. 70) (Refer to the next page.) onfirm protect status. UNLOK: Disables the Protect function. The Protect function can be set while unlocked. LOK: Enables the Protect function, and validates the Protect function settings. [Enabling and disabling the Protect function] Press the Setting knob while holding down the Utility key to enable the Protect function and lock the system. (The System Lock indicator lights.) To release the lock and disable the Protect function, press the Setting knob again while holding down the Utility key. (The System lock indicator extinguishes.) Note Both the system lock and unlock operations automatically save the configuration. [Keys that can be protected] UTILITY PRESET System lock indicator DIGITAL MIXER model D-90 LOK ENTRY SETI PRESET ALL UTILITY URSOR HG PARAM * SELET DIGITAL MIXER model D-90 7 PEAK 8 +db +6dB UTILITY dB -6dB 3 4 PRESET LOK 5 6 SEL SIG 0N 0N SIG SEL SEL -db -0dB -40dB POWER OFF ENTRY SETI 5 FBS 0N SIG SEL 8 6 EFFET PRESET INPUT MI BUS OUTPUT PRESET LOAD INPUT EFFET OUTPUT 68 * Bus assignment operations by way of the Input and Output channel selector keys are also locked and disabled.

69 Rotate the Setting knob to select the key(s) to be protected. The Protect function can be enabled or disabled for the selected key(s) by pressing the function /OFF key. [UTY ] PROTET ALL : Enables or disables the Protect function for all keys. : Simultaneously enables the Protect function for all keys. ---: Enables the Protect function for a part of keys. OFF: Simultaneously disables the Protect function for all keys. [UTY ] PROTET U T I L I T Y : Enables or disables the Protect function for the Utility key. When enabled (), the Utility function cannot be set. [UTY ] PROTET PRESET : Enables or disables the Protect function for the Preset key. When enabled (), the Preset Memory function cannot be set using the Preset key. (Preset memory can be recalled using the Preset memory selector keys.) [UTY ] PROTET HG P ARAM : Enables or disables the Protect function for the Setting knob, the Function /OFF key, and bus assignment operation by way of the Input and Output channel selector keys. When enabled (), parameters cannot be set. [UTY ] PROTET URSOR : Enables or disables the Protect function for the Screen shift keys. When enabled (), screen displays cannot be changed with the shift keys. [UTY ] LOAD PROTET : Enables or disables the Protect function for the Preset memory selector keys ( 8). When enabled (), preset memory cannot be recalled using the Preset memory selector keys. (Preset function can be set using the Preset keys.) [UTY ] PROTET I NPUT : Enables or disables the Protect function for the Input volume control and the Input channel /OFF key. When enabled (), the input volume cannot be adjusted with the Input volume control, and the input channels cannot be enabled or disabled. [UTY ] PROTET OUTPUT : Enables or disables the Protect function for the Output volume control and the Output channel /OFF key. When enabled (), the output volume cannot be adjusted with the Output volume control, and the output channels cannot be enabled or disabled. [UTY ] PROTET SELET : Enables or disables the Protect function for the Input channel selector keys, the Output channel selector keys, and the Microphone bus selector key. When enabled (), the selector keys cannot be used. [UTY ] PROTET EFFET KEY : Enables or disables the Protect function for the Effect key. When enabled (), the Effect key cannot be used. 69

70 .7. RS-3 Port Settings [Screen display operations] Protect settings (p. 68) ontrol mode selection [UTY] RS-3 MODE NE RS-3 transmission rate [UTY] RS-3 500bps Tip Settings are automatically saved as system data, and setting status is maintained even if the power is turned off. All input/output channel gain confirmation (next page).7.. ontrol mode selection [UTY] RS-3 MODE P TRL Rotate the Setting knob to select the mode that matches the type of equipment connected to the unit's RS-3 port. UPDATE: A P is connected to update the unit's firmware using the utility program. (Refer to p. 74.) REMOTE: A conventional remote controller (AMX, restron, etc.) is connected. P TRL: A P is connected to control the unit using the dedicated setting software program (to be downloaded from our International site, see below). Tips While the D-90 is communicating with a P, the front-mounted system lock indicator flashes. In the above status, attempting to change settings with the front-mounted knobs or keys notifies the operator of prohibited operation by way of the indication shown below. P on t r o l Mode Key Locked To enforce the termination of communications with the P, press the Setting knob holding down the Function /OFF key. The control protocol and setting software program are available for download at our website: RS-3 transmission rate settings [UTY] RS-3 Rotate the Setting knob to set the RS-3 transmission rate. Parameter setting range: 500, 38400, 900, 9600 bps 500bps 70

71 .8. All Input/Output hannel Gain onfirmation RS-3 port settings (previous page) [ UTY ] ALL FADER POS I T I I N OU T Gains of all input channels can be simultaneously confirmed. hannels are Input Nos. through from left to right. Gains of all output channels can be simultaneously confirmed. hannels are Output Nos. through 8 from left to right..9. All Input/Output VA Status onfirmation (Only when the D-984V is used) All input/output channel gain confirmation (previous section) [UTY] ALL VA POS I T I V I N VA OUT Module type confirmation (next page) VA status of all Input channels can be simultaneously confirmed. hannels are Input Nos. through from left to right. Maximum value: 0 V, Minimum value: 5 V VA status of all output channels can be simultaneously confirmed. hannels are Input Nos. through 8 from left to right. Maximum value: 0 V, Minimum value: 5 V Note The above screens show the statuses of VA input and output terminals. When channels are set for the stereo link or group, all their gains change synchronizing with the lowest numbered channel's gain. Irrespective of these settings for channels, the VA statuses are displayed for individual channels as shown above. 7

72 .0. Module Type onfirmation Types of modules installed in the unit's rear slots can be confirmed. [Screen display operations] All input/output channel gain confirmation (previous section) Individual slots confirmation [UTY] SLOT :D-9F/E(A) All slots confirmation SLOT: TYPE : AABB DEF [UTY] SLOT :D-9F/E(A) [UTY] SLOT 9 : D ( F ) ooling fan operation status confirmation (next page).0.. Individual slots confirmation [ UTY ] SLOT :D-9F/E(A) Rotate the Setting knob to confirm the type of module installed in each slot. The slot number and installed module type are displayed on the lower row. The module types are as follows: D-9F or D-9E: D-9F/E (A) D-9F or D-9E: D-9F/E (B) D-936R: D-936R () D-97M or D-97E: D-97M/E (D) D-97R: D-97R (E) D-98: D-98 (F) No module installed: BLANK ( ) D-93AE: D-93AE (I) D-937SP: D-937SP (J) D-96SP: D-96SP (K) D-97AE: D-97AE (L) D-983: D-983 (M) D-984V: D-984V (N) For the slot where a wrong module is inserted (for example, an output module is inserted into an input slot), "( )" is displayed. 7

73 .0.. All slots confirmation SLOT: TYPE : AABB DEF Slot numbers are displayed on the upper row, and the inserted module types on the lower row. A: D-9E or D-9F Microphone/line input module B: D-9E or D-9F Microphone/line input module : D-936R Stereo input module D: D-97E or D-97M Line output module E: D-97R Line output module (RA connector) F: D-98 Remote control module I: D-93AE Digital input module J: D-937SP Digital input module K: D-96SP Digital output module L: D-97AE Digital output module M: D-983 Remote control module N: D-984V VA control module : Blank : A wrong module installed When a wrong module is inserted into a slot, the initial screen that indicates the relevant slot with " " mark appears after the unit's power is switched as shown below. ERROR HEK SLOT.. ooling Fan Operating Status onfirmation Module type confirmation (previous page) [UTY] FAN RUNN I NG The operating status of the rear-mounted cooling fan can be confirmed on the screen. Normal operation: [UTY] FAN RUNN I NG Operation failure: [UTY] FAN W ARN I NG When "ERROR" is displayed, check to be sure that the fan exhaust vent is not blocked or that a foreign object has not jammed the vent. The fan is detected as having failed when it stops or if its rotation speed is extremely slow. In such cases contact your TOA dealer. If the fan rotation speed decreases dramatically, the display switches over to the cooling fan failure screen even when another screen is displayed. Pressing the Setting knob turns off the failure indication... Firmware Version onfirmation [ UTY ] VERS I The firmware version number can be confirmed. 73

74 OFF 3. RESTORING FATORY DEFAULT SETTINGS Perform the following procedure to reset all parameters to the factory default settings. Step. Turn the power switch OFF. Step. Turn the power switch while holding down both the and shift keys. Keep pressing both keys until "[SYSTEM] Initialize OK?" is displayed on the LD screen. UTILITY PRESET DIGITAL MIXER model D-90 LOK POWER ENTRY SETI PRESET Step 3. Press the Setting knob. The LD screen display changes to "[SYSTEM] Initializing..." Then, all parameters are reset to the factory default settings, and the Input/Output Gain Setting screen is displayed. Note The factory default Bus Assignment setting is made so that each input ( ) is assigned to all outputs ( 8) via the Microphone Bus. Other default parameters are shown on p [ SYSTEM] I n i t i a l i z e OK? [ SYSTEM] I n i t i a l i z i n g... I N ] [ OU T ] INFdB 0.0dB 4. FIRMWARE UPDATE The D-90's firmware can be updated using the software program (D90Pvxxxe_fxxx.exe)* made available on the TOA internet site [ To update the firmware, download the software program to install it into your P. (For the installation procedure, refer to the "D90 P Software Instruction Manual" also available on the same site.) The firmware update is performed by using the D-90 Firmware Update Utility program simultaneously installed with the D-90 P Software. Follow the procedure for the firmware update below. After updating the firmware, use the latest D-90 instruction manual that can also be downloaded from the website above. * The software version number can be confirmed at the xxx indication. For example when the P Software version is 3.00 and Firmware version is 3.0, it is indicated as "D90Pv300e_f30.exe. Step. onnect both RS-3 ports of the D-90 and the P using a 9-pin straight cable (male-to-female cord). Step. Make RS-3 port settings at the D-90. Set the control mode to "UPDATE* " and the transmission rate to "500 bps" (recommended). (Refer to p. 70.) * Set "NE" for the version.xx firmware. 74

75 Step 3. Select the menu items [Start Program TOA Digital Audio ontrol Update D-90 Firmware]. The D-90 Firmware Update screen appears The default communication settings are as follows: ommunication port: OM Baud rate: 500 bps Unless otherwise necessary to change, follow Step 6. To change the settings, follow Step 4. Step 4. lick the omm Settings button. The omm Settings screen appears. Step 5. Set the P's om port the D-90 is connected to, and the Speed (baud rate*) equal to the D-90's RS-3 transmission rate. lick OK, then the omm Settings screen closes. * Set the same value as that set in Step. Step 6. lick the Update button of the D-90 Firmware Update screen. The firmware update starts being transferred from the P to the D-90. The following screen appears after the update ends. 75

INFRARED WIRELESS DISTRIBUTOR

INFRARED WIRELESS DISTRIBUTOR OPERATING INSTRUCTIONS INFRARED WIRELESS DISTRIBUTOR IR-700D Thank you for purchasing TOA's Infrared Wireless Distributor. Please carefully follow the instructions in this manual to ensure long, trouble-free

More information

AM/FM SYNTHESIZER TUNER

AM/FM SYNTHESIZER TUNER OPERATING INSTRUCTIONS AM/FM SYNTHESIZER TUNER DT-930 UL TABLE OF CONTENTS 1. IMPORTANT SAFETY INSTRUCTIONS... 2 2. SAFETY PRECAUTIONS... 2 3. INFORMATION TO THE USER... 3 4. GENERAL DESCRIPTION... 3 5.

More information

S5-ADU. Front... 4 Rear... 4

S5-ADU. Front... 4 Rear... 4 Trantec ANTENNA DISTRIBUTOR INSTRUCTION MANUAL S5-ADU Thank you for purchasing TRANTEC Antenna Distributor. Please carefully follow the instructions in this manual to ensure long, trouble-free use of your

More information

IP Series DUAL POWER AMPLIFIERS

IP Series DUAL POWER AMPLIFIERS OPERATING INSTRUCTIONS IP Series DUAL POWER AMPLIFIERS IP-600D IP-450D IP-300D TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 2 2. GENERAL DESCRIPTION... 4 3. FEATURES... 4 4. HANDLING PRECAUTIONS... 4 5.

More information

INSTRUCTION MANUAL POWERED MIXER MX-628

INSTRUCTION MANUAL POWERED MIXER MX-628 INSTRUCTION MANUAL POWERED MIXER MX-628 Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for future reference.

More information

FS-7006PA FS-7012PA YA-7000 POWER AMPLIFIERS. AMPLIFIER AUTO SWITCHING MODULE (Optional) OPERATING INSTRUCTIONS

FS-7006PA FS-7012PA YA-7000 POWER AMPLIFIERS. AMPLIFIER AUTO SWITCHING MODULE (Optional) OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS POWER AMPLIFIERS AMPLIFIER AUTO SWITCHING MODULE (Optional) FS-7006PA FS-7012PA YA-7000 Thank you for purchasing TOA's Power Amplifiers. Please carefully follow the instructions

More information

USER MANUAL VIVALDI MZ550A. Distribution Mixer Amplifier

USER MANUAL VIVALDI MZ550A. Distribution Mixer Amplifier USER MANUAL VIVALDI MZ550A Distribution Mixer Amplifier 1. Security Precautions Carefully READ the instruction in this manual before use. Be sure to OBSERVE the INSTRUCTION in this manual regard convention

More information

MIXER POWER AMPLIFIER BG-130

MIXER POWER AMPLIFIER BG-130 OPERATING INSTRUCTIONS MIXER POWER AMPLIFIER BG-115 BG-130 TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL

More information

UHF WIRELESS TUNER CHANNEL TUNER 2 DIVERSITY WIRELESS TUNER WT-4820 O O

UHF WIRELESS TUNER CHANNEL TUNER 2 DIVERSITY WIRELESS TUNER WT-4820 O O PERATG STRUCTIS UHF WIRELESS TUNER WT-480 10 10 TABLE F CTENTS 1. SAFETY PRECAUTIS.... GENERAL DESCRIPTI.... FEATURES... 4. HANDLG PRECAUTIS... 5. NMENCLATURE AND FUNCTIS Front... 4 Rear... 4 6. STALLG

More information

DIGITAL AMBIENT NOISE CONTROLLER

DIGITAL AMBIENT NOISE CONTROLLER OPERATING INSTRUCTIONS DIGITAL AMBIENT NOISE CONTROLLER DP-L Thank you for purchasing TOA's Digital Ambient Noise Controller. Please carefully follow the instructions in this manual to ensure long, trouble-free

More information

T-60 T-120 T-240 T-350 PUBLIC ADDRESS SYSTEM MIXER AMPLIFIER

T-60 T-120 T-240 T-350 PUBLIC ADDRESS SYSTEM MIXER AMPLIFIER - - - + - + + + - - - + - + + + 4 6 AUDIO OPERATION MANUAL ON OFF POWER T- MIXER AMPLIFIER BASS TREBLE MIC MIC MIC AUX T-6 T- T T- MIXER AMPLIFIER Please follow the instructions in this manual to obtain

More information

DUAL POWER AMPLIFIERS DA-250D CU DA-250DH CU OPERATING INSTRUCTIONS

DUAL POWER AMPLIFIERS DA-250D CU DA-250DH CU OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS DUAL POWER AMPLIFIERS DA-250D CU DA-250DH CU Note: The figure shows the DA-250D. Thank you for purchasing TOA's Dual Power Amplifier. Please carefully follow the instructions in

More information

INFRARED WIRELESS TUNER

INFRARED WIRELESS TUNER ON OFF OPERATING INSTRUCTIONS INFRARED WIRELESS TUNER IR-702T CH A VOLUME IR CH B VOLUME IR POWER This manual describes the installation and usage of the entire system* using the IR-702T Infrared Wireless

More information

INSTALLATION MANUAL VOICE EVACUATION SYSTEM FS-7000 SERIES

INSTALLATION MANUAL VOICE EVACUATION SYSTEM FS-7000 SERIES INSTALLATION MANUAL VOICE EVACUATION SYSTEM FS-7000 SERIES Thank you for purchasing TOA's Voice Evacuation System. Please carefully follow the instructions in this manual to ensure long, trouble-free use

More information

MIXING CONSOLE CX-124 CX-164. TOA Corporation. Operating Instructions

MIXING CONSOLE CX-124 CX-164. TOA Corporation. Operating Instructions MIXING CONSOLE Operating Instructions CX-124 CX-164 Please follow the instructions in this manual to obtain the optimum results from these units. We also recommend you to keep this manual handy for future

More information

UHF WIRELESS MICROPHONE WM-5320A WM-5320H

UHF WIRELESS MICROPHONE WM-5320A WM-5320H OPERATING INSTRUCTIONS UHF WIRELESS MICROPHONE WM-5320 WM-5320A WM-5320H Thank you for purchasing TOA's UHF Wireless Microphone. Please carefully follow the instructions in this manual to ensure long,

More information

SA 125 mixer amplifier. user manual

SA 125 mixer amplifier. user manual SA 125 mixer amplifier user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 27.10.2016,

More information

UHF WIRELESS SET WS-200/300

UHF WIRELESS SET WS-200/300 OPERATING INSTRUCTIONS UHF WIRELESS SET WS-200/300 Thank you for purchasing TOA s UHF Wireless Set. Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment/

More information

9000M2 SERIES PRE-AMPLIFIER M-9000M2

9000M2 SERIES PRE-AMPLIFIER M-9000M2 INSTALLATION AND OERATING INSTRUCTIONS (Applicable to the M-9000M2 firmware Ver. 2.00 or later) 9000M2 SERIES RE-AMLIFIER M-9000M2 lease also read the separate instruction manual for the programming software

More information

SUB-WOOFER SYSTEM OPERATING INSTRUCTIONS TABLE OF CONTENTS 1. SAFETY PRECAUTIONS GENERAL DESCRIPTION FEATURES... 3

SUB-WOOFER SYSTEM OPERATING INSTRUCTIONS TABLE OF CONTENTS 1. SAFETY PRECAUTIONS GENERAL DESCRIPTION FEATURES... 3 OPERATING INSTRUCTIONS SUB-WOOFER SYSTEM FB-100 Please follow the instructions in this manual to obtain optimum results from this unit. We also recommend that you keep this manual handy for future reference.

More information

SYSTEM MANAGEMENT AMPLIFIER VM-2120 (120 W) VM-2240 (240 W) RM-200M RM-210 EV-200 SV-200M

SYSTEM MANAGEMENT AMPLIFIER VM-2120 (120 W) VM-2240 (240 W) RM-200M RM-210 EV-200 SV-200M INSTRUCTION MANUAL SYSTEM MANAGEMENT AMPLIFIER REMOTE MICROPHONE REMOTE MICROPHONE EXTENSION VOICE ANNOUNCEMENT BOARD SURVEILLANCE BOARD VM-2120 (120 W) VM-2240 (240 W) RM-200M RM-210 EV-200 SV-200M RM-200M

More information

mix 502, mix 802, mix 1202FX mixer user manual

mix 502, mix 802, mix 1202FX mixer user manual mix 502, mix 802, mix 1202FX mixer user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de

More information

INTEGRATED VOICE EVACUATION SYSTEM VM-3000 Series

INTEGRATED VOICE EVACUATION SYSTEM VM-3000 Series OPERATION MANUAL INTEGRATED VOICE EVACUATION SYSTEM VM-3000 Series VOICE ALARM SYSTEM AMPLIFIER VM-3240VA VOICE ALARM SYSTEM AMPLIFIER VM-3360VA VM EXTENSION AMPLIFIER VM-3240E VM EXTENSION AMPLIFIER VM-3360E

More information

M-300 Mono power amplifier User s guide

M-300 Mono power amplifier User s guide M-300 Mono power amplifier User s guide M-300 Mono power amplifier User s guide Specifications: Contents: Power output: 8Ω: 290W, 0.01% THD SPECIFICATIONS Page 2 Input impedance: Gain: 4Ω: 580W, 0.01%

More information

ZM-6. Professional 19 Rack Mixer USER MANUAL. Content

ZM-6. Professional 19 Rack Mixer USER MANUAL. Content Professional 19 Rack Mixer ZM-6 USER MANUAL Thank you for buying an LD Systems audio product. Please read these operating instructions carefully before you use the product for the first time and keep them

More information

9000M2 SERIES AMPLIFIERS A-9060DHM2 A-9120DHM2 A-9060SM2 A-9120SM2 A-9240SHM2

9000M2 SERIES AMPLIFIERS A-9060DHM2 A-9120DHM2 A-9060SM2 A-9120SM2 A-9240SHM2 INSTALLATION AND OERATING INSTRUCTIONS (Applicable to the 9000M2 firmware Ver. 2.00 or later) 9000M2 SERIES AMLIFIERS M-9000M2 A-9060DHM2 A-9120DHM2 A-9060SM2 A-9120SM2 A-9240SHM2 lease also read the separate

More information

PM7400MKII. Instruction manual

PM7400MKII. Instruction manual PM7400MKII Instruction manual PM7400MKII Instruction manual 3 PM7400MKII Manual 4 Pre-amplifier Safety first! Caution: hot and sharp surfaces! This professional device needs to be installed by qualified

More information

INFRARED CONFERENCE SYSTEM TS-900 series

INFRARED CONFERENCE SYSTEM TS-900 series OPERATING INSTRUCTIONS INFRARED CONFERENCE SYSTEM TS-900 series TS-905/-907 TS-902/-903 TS-900 TS-901/-903 Thank you for purchasing TOA's Infrared Conference System. Please carefully follow the instructions

More information

a u d i o p h i l e d i g i t a l - t o - a n a l o g u e c o n v e r t e r user guide

a u d i o p h i l e d i g i t a l - t o - a n a l o g u e c o n v e r t e r user guide DAC30 a u d i o p h i l e d i g i t a l - t o - a n a l o g u e c o n v e r t e r user guide Welcome! Welcome to the Primare DAC30! Your DAC30 is a fully balanced audiophile digitalto-analogue converter,

More information

User Manual. MA 21 Two zone mixing amplifier

User Manual. MA 21 Two zone mixing amplifier User Manual MA 21 Two zone mixing amplifier Safety instructions When using this electronic device, basic precautions should always be taken, including the following: 1 Read all instructions before using

More information

E-800 power amplifier. user manual

E-800 power amplifier. user manual E-800 power amplifier user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 20.05.2016,

More information

ECA COMMERCIAL AMPLIFIER OWNER S MANUAL ECA-70MIXAMP V / 70V / 4Ω Amplifier ECA-70MIXAMP-1-60 OUTPUT LEVEL POWER MASTER MIC 1

ECA COMMERCIAL AMPLIFIER OWNER S MANUAL ECA-70MIXAMP V / 70V / 4Ω Amplifier ECA-70MIXAMP-1-60 OUTPUT LEVEL POWER MASTER MIC 1 OWNER S MANUAL ECA COMMERCIAL AMPLIFIER ECA-MIXAMP--6 V / V / Ω Amplifier TEMP PROT OUTPUT LEVEL ECA-MIXAMP--6 6 POWER MIC MIC MIC MIC AUX AUX BASS TREBLE 5 5 5 5 5 6 6 6 6 6 MASTER 5 6 ON OFF + - + -

More information

Single Channel Radio Mic System USER MANUAL. WMU-116-H (Hand Held) WMU-116-B (Belt Pack) Single Channel Radio Mic System

Single Channel Radio Mic System USER MANUAL. WMU-116-H (Hand Held) WMU-116-B (Belt Pack) Single Channel Radio Mic System Single Channel Radio Mic System USER MANUAL WMU-116-H (Hand Held) WMU-116-B (Belt Pack) Single Channel Radio Mic System Welcome Thank you for choosing Hill Audio for your sound system. To make sure that

More information

SAGA PRO SERIES STEREO POWER AMPLIFIER OPERATION MANUAL

SAGA PRO SERIES STEREO POWER AMPLIFIER OPERATION MANUAL SAGA PRO SERIES STEREO POWER AMPLIFIER OPERATION MANUAL INSTALLATION Use care in unpacking the amplifier, and be sure to save the carton and packing materials so that you can use them for moving, storing,

More information

E-800 power amplifier. user manual

E-800 power amplifier. user manual E-800 power amplifier user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 03.06.2013 Table of contents

More information

DPAfour125, DPAfour250 AMPLIFIERS. Operating Manual

DPAfour125, DPAfour250 AMPLIFIERS. Operating Manual DPAfour125, DPAfour250 AMPLIFIERS Operating Manual Operating manual, DPA Series DPA-10UMS01-V01R04 version revision date 01 02 24-02-2012 www.ateis-europe.com ATEÏS Europe BV - Sydneystraat 42-3047BP ROTTERDAM

More information

E-400 power amplifier. user manual

E-400 power amplifier. user manual E-400 power amplifier user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: (09546) 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 07.03.2014, ID: 173888 Table

More information

Operating Instruction Manual ELECTRONIC MUSIC AMPLIFICATION SYSTEM. Model KD-1. Toa Electric Co., Ltd. KOBE, JAPAN

Operating Instruction Manual ELECTRONIC MUSIC AMPLIFICATION SYSTEM. Model KD-1. Toa Electric Co., Ltd. KOBE, JAPAN Operating Instruction Manual ELECTRONIC MUSIC AMPLIFICATION SYSTEM Model KD-1 Toa Electric Co., Ltd. KOBE, JAPAN Contents Precautions... 1 General Description... 2 Features... 2 Front Panel: Names of components

More information

Block-800B bass head. user manual

Block-800B bass head. user manual Block-800B bass head user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Deutschland Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 08.03.2018,

More information

PROLUDE AMPLIFICATION D750. User s manual for the tube preamplifier version

PROLUDE AMPLIFICATION D750. User s manual for the tube preamplifier version PROLUDE AMPLIFICATION D750 User s manual for the tube preamplifier version 1 2 Table of contents 1 INTRODUCTION...1 4 1.1 SOME WORDS TO THE CUSTOMER...1 4 1.2 SOME WORDS ABOUT ME...1 4 2 SAFETY INSTRUCTIONS,

More information

OPERATING INSTRUCTIONS NETWORK INTERCOM SYSTEM AN-8000 SERIES

OPERATING INSTRUCTIONS NETWORK INTERCOM SYSTEM AN-8000 SERIES OPERATING INSTRUCTIONS NETWORK INTERCOM SYSTEM AN-8000 SERIES Thank you for purchasing AIPHONE's Network Intercom system. Please carefully follow the instructions in this manual to ensure long, trouble-free

More information

Q-Tech. Q-Tech Commercial Series QTA 6060M/6130M Mixer Amplifiers. User Manual

Q-Tech. Q-Tech Commercial Series QTA 6060M/6130M Mixer Amplifiers. User Manual Q-Tech QTA 6060M/6130M Mixer Amplifiers Contents Safety Precautions... 1 General Description.... 4 Features.... 4 Front Panel Layout............................. 5 Rear Panel Layout... 6 Connections..................................

More information

Z44R. Multi-purpose Rack Mixer. Item ref: User Manual

Z44R. Multi-purpose Rack Mixer. Item ref: User Manual Z44R Multi-purpose Rack Mixer Item ref: 953.020 User Manual 2 balanced microphone inputs Lo-cut rumble filters 3-band EQ per Mic channel Switchable 48V phantom power 2 x A/B selectable stereo line inputs

More information

User Manual. MA 240 Mixing amplifier

User Manual. MA 240 Mixing amplifier User Manual MA 240 Mixing amplifier Safety instructions When using this electronic device, basic precautions should always be taken, including the following: 1 Read all instructions before using the product.

More information

LA-SERIES LOOP AMPLIFIERS. Item ref: UK, UK User Manual

LA-SERIES LOOP AMPLIFIERS. Item ref: UK, UK User Manual LA-SERIES LOOP AMPLIFIERS Item ref: 952.864UK, 952.867UK User Manual Caution: Please read this manual carefully before operating Damage caused by misuse is not covered by the warranty SAFETY SYMBOL AND

More information

POWERED MONITOR SPEAKER MSP10STUDIO

POWERED MONITOR SPEAKER MSP10STUDIO POWERED MONITOR SPEAKER MSP10STUDIO Owner s manual Mode d emploi Bedienungsanleitung Manual de instrucciones M Thank you for purchasing the Yamaha MSP10STUDIO powered monitor speaker system. The MSP10STUDIO

More information

3.Avoid spilling liquids or allowing materials to enter the cabinet

3.Avoid spilling liquids or allowing materials to enter the cabinet PUBLIC ADDRESS MIXER POWER AMPLIFIER INSTRUCTION MANUAL PL-260A 260 WATT RMS RISK OF ELECTRIC SHOCK, DO NOT OPEN! CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT OPEN COVER. NO USER SERVICEABLE PARTS

More information

Mixer Amplifier series

Mixer Amplifier series Mixer Amplifier series with MP & FM Tuner User Manual MA MP MIXER AMPLIFIER MIC MIC AUX US B/S D/F M BASS - - + - + + - + - - + - TREBLE + - AUX MIC/LINE + + - MIXER + MA MP + - AMPLIFIER MIC MIC AUX MIC/LINE

More information

TFX256 PRO. Digital Effect Processor

TFX256 PRO. Digital Effect Processor TFX PRO Digital Effect Processor SAFTY PRECAUTIONS SAFETY PRECAUTIONS! WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE. Do not allow water or liquids

More information

Power Amplifier D2 D3 D4 D5 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Dual Channel Power Amplifier D2 D3 D4 D5. User Manual & Installation Guide

Power Amplifier D2 D3 D4 D5 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Dual Channel Power Amplifier D2 D3 D4 D5. User Manual & Installation Guide Power Amplifier D2 D3 D4 D5 AUDAC PROFESSIONAL AUDIO EQUIPMENT Dual Channel Power Amplifier D2 D3 D4 D5 User Manual & Installation Guide AUDAC PROFESSIONAL AUDIO EQUIPMENT User Manual & Installation Guide

More information

E4-130, E4-250 power amplifier. user manual

E4-130, E4-250 power amplifier. user manual E4-130, E4-250 power amplifier user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 30.10.2014, ID:

More information

10/12/15 inches 2-way amplified speakers with bass reflex

10/12/15 inches 2-way amplified speakers with bass reflex 10/12/15 inches 2-way amplified speakers with bass reflex USER GUIDE 10157 / 10158 / 10159 - January 2014 Version 1.0 English SR10A / SR12A / SR15A - 10/12/15 inches 2-way amplified speakers with bass

More information

INSTRUCTION MANUAL FUNCTION GENERATOR FG-274 B

INSTRUCTION MANUAL FUNCTION GENERATOR FG-274 B INSTRUCTION MANUAL FUNCTION GENERATOR FG-274 B71-0173-11 CONTENTS USING THE PRODUCT SAFELY Ⅰ-Ⅳ 1. FEATURES... 1 2. SPECIFICATIONS... 2 3. FRONT AND REAR PANELS... 5 3.1. Front Panel... 5 3.2. Rear Panel...

More information

TOA NEW 900 SERIES MIXER PREAMPLIFIER M-900A

TOA NEW 900 SERIES MIXER PREAMPLIFIER M-900A Operation Instruction Manual TOA NEW 900 SERIES MIXER PREAMPLIFIER M-900A Features General Description 1 6-channel mixer preamplifier 2 Wide frequency response; 20 20,000Hz, ±1dB 3 Low distortion and noise

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS When using this electronic device, basic precautions should always be taken, including the following: 1. Read all instructions before using the product. 2. Do not use this

More information

POWER AMPLIFIER. Owner s Manual Mode d emploi Bedienungsanleitung Manual de instrucciónes CLIP SIGNAL TEMP PROTECTION POWER

POWER AMPLIFIER. Owner s Manual Mode d emploi Bedienungsanleitung Manual de instrucciónes CLIP SIGNAL TEMP PROTECTION POWER POWER AMPLIFIER Owner s Manual Mode d emploi Bedienungsanleitung Manual de instrucciónes TEMP PROTECTION POWER A CLIP SIGNAL B ON OFF M Introduction Thank you for purchasing a Yamaha C450/320/160 series

More information

PROFESSIONAL STEREO AMPLIFIERS USER GUIDE

PROFESSIONAL STEREO AMPLIFIERS USER GUIDE PROFESSIONAL STEREO AMPLIFIERS USER GUIDE 967/9673 - September 00 - Version.0 ENGLISH Ti SERIES - Professional stereo amplifiers Page Ti SERIES - Professional stereo amplifiers ENGLISH - Safety information

More information

A32. f u l l y b a l a n c e d p o w e r a m p l i f i e r. user guide

A32. f u l l y b a l a n c e d p o w e r a m p l i f i e r. user guide A32 f u l l y b a l a n c e d p o w e r a m p l i f i e r user guide Welcome! Welcome to the Primare A32 Amplifier! The A32 is a modular power amplifier designed as the ideal output stage in a home theatre

More information

TMP40. User Manual.

TMP40. User Manual. TMP40 User Manual www.audac.eu ADDITIONAL INFORMATION This manual is put together with much care, and is as complete as could be on the publication date. However, updates on the specifications, functionality

More information

PREMIUMAUDIOVIDEOLIGHTINGANDPOWERPRODUCTS

PREMIUMAUDIOVIDEOLIGHTINGANDPOWERPRODUCTS FACTOR ELECTRONICS PREMIUMAUDIOVIDEOLIGHTINGANDPOWERPRODUCTS VT-1 / VT-4 Professional Tuners With RBDS Owners Manual Owners Manual IMPORTANT NOTE: THIS OWNER'S MANUAL IS PROVIDED AS AN INSTALLATION AND

More information

Primare A33.2 Amplifier User Guide

Primare A33.2 Amplifier User Guide > Primare A33.2 Amplifier User Guide > Preface CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electrical shock do not remove cover (or back). No user serviceable parts inside.

More information

TOA 900 SERIES POWER AMPLIFIER P-924A

TOA 900 SERIES POWER AMPLIFIER P-924A Operation Instruction Manual TOA 900 SERIES POWER AMPLIFIER P-924A Features General Descriptions 1 Wide frequency response; 20 20,000 Hz, ±1dB 2 Low distortion and noise level 3 Excellent output regulation

More information

E-400 endstufe. user manual

E-400 endstufe. user manual E-400 endstufe user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0)9546 9223-66 email: info@thomann.de Internet: www.thomann.de 02.12.2011 Table of contents Table

More information

MULTIPLE OUTPUT DIGITAL DELAY

MULTIPLE OUTPUT DIGITAL DELAY Operating Instruction Manual MULTIPLE OUTPUT DIGITAL DELAY Model 310D Toa Electric Co., Ltd. KOBE, JAPAN Contents Precautions...1 General Description...2 Features...2 Front Panel...3 Rear Panel...4 Sample

More information

User Manual. imix 63 Stereo mixing preamplifier

User Manual. imix 63 Stereo mixing preamplifier User Manual imix 63 Stereo mixing preamplifier Safety instructions When using this electronic device, basic precautions should always be taken, including the following: 1 Read all instructions before using

More information

DA216S DISTRIBUTION AMPLIFIER

DA216S DISTRIBUTION AMPLIFIER DISTRIBUTION AMPLIFIER IMPORTANT SAFETY INSTRUCTIONS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6.

More information

TOA 500 SERIES MIXER POWER AMPLIFIER

TOA 500 SERIES MIXER POWER AMPLIFIER TOA 500 SERIES MIXER POWER AMPLIFIER Operation Instruction Manual A-503A A-506A A-512A Features General Description 1. High quality design and construction. 2. Full frequency response: 50-15,000Hz, ±3dB.

More information

OPERATING INSTRUCTIONS PACKET INTERCOM SYSTEM N-8000 SERIES

OPERATING INSTRUCTIONS PACKET INTERCOM SYSTEM N-8000 SERIES OPERATING INSTRUCTIONS PACKET INTERCOM SYSTEM N-8000 SERIES Thank you for purchasing TOA's Packet Intercom system. Please carefully follow the instructions in this manual to ensure long, trouble-free use

More information

KTC-HR300 INSTRUCTION MANUAL

KTC-HR300 INSTRUCTION MANUAL HD Radio TUNER UNIT KTC-HR300 INSTRUCTION MANUAL Take the time to read through this instruction manual. Familiarity with installation and operation procedures will help you obtain the best performance

More information

MLM82S MIC / LINE MIXER

MLM82S MIC / LINE MIXER MLMS MIC / LINE MIXER IMPORTNT SFETY INSTRUCTIONS. Read these instructions.. Keep these instructions. 3. Heed all warnings.. Follow all instructions. 5. Do not use this apparatus near water.. Clean only

More information

PROFESSIONAL FOUR-CHANNEL AUDIO MIXER WITH DSP PROCESSOR

PROFESSIONAL FOUR-CHANNEL AUDIO MIXER WITH DSP PROCESSOR PROFESSIONAL FOUR-CHANNEL AUDIO MIXER WITH DSP PROCESSOR Thank you for purchasing the professional four-channel audio mixer with DSP processor! For the best results and the utmost satisfaction from your

More information

Warning: Electrical Hazard... 3 Safety Instruction Sheet for STG Product Overview What s in the box?... 4

Warning: Electrical Hazard... 3 Safety Instruction Sheet for STG Product Overview What s in the box?... 4 STG-2412 User Guide Warning: Electrical Hazard... 3 Safety Instruction Sheet for STG-2412... 3 Product Overview... 4 What s in the box?... 4 Using STG-2412 for Mixing, Processing, and Recording... 5 Software

More information

T L Audio. User Manual EQ1 VALVE EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

T L Audio. User Manual EQ1 VALVE EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England. T L Audio User Manual EQ1 VALVE EQUALISER Tony Larking Professional Sales Limited, Letchworth, England. Tel: 01462 490600, International +44 1462 490600. Fax: 01462 490700, International +44 1462 490700.

More information

WPE 48N USER MANUAL Version1.1

WPE 48N USER MANUAL Version1.1 Version1.1 Security instructions 1. Read this manual carefully. 2. Follow all instructions and warnings. 3. Only use accessories specified by WORK PRO. 4. Follow the safety instructions of your country.

More information

Owner s Manual. Keep This Manual For Future Reference. 2 HIGH 1 HIGH 3 HIGH EFFECT DIGITAL EFFECT MONITOR INST 1. Hi-Z. Hi-Z. Hi-Z EFFECT OUT.

Owner s Manual. Keep This Manual For Future Reference. 2 HIGH 1 HIGH 3 HIGH EFFECT DIGITAL EFFECT MONITOR INST 1. Hi-Z. Hi-Z. Hi-Z EFFECT OUT. Owner s Manual HIGH HIGH HIGH 3 HIGH 4 HIGH 5 HIGH SEE REAR PANEL CAUTI POWER VOCAL 5 +5 LOW 5 +5 LOW 5 +5 LOW 5 +5 LOW 5 +5 LOW 5 +5 LOW L HALL PHANTOM 5 +5 5 +5 5 +5 5 +5 5 +5 5 +5 S HALL OFF MI MI MI

More information

KMA-1080/KMA-980 Digital Karaoke Mixing Amplifier

KMA-1080/KMA-980 Digital Karaoke Mixing Amplifier L KMA-1080/KMA-980 Digital Karaoke Mixing Amplifier OWNER S MANUAL MANUAL DE INSTRUCCIONES Caution: Read this before operating your unit 1 To assure the finest performance, please read this manual carefully.

More information

DSR-3. Bedienungsanleitung User Guide

DSR-3. Bedienungsanleitung User Guide DSR-3 Bedienungsanleitung User Guide EN Introduction The invention of the Hammond organ in the last century's mid 30s resulted in a need for artificial reverb. This led to the development of spring reverberation

More information

System Integration 2CH Amplifier

System Integration 2CH Amplifier 2-514-603-12(1) System Integration 2CH Amplifier Installation Manual Owner s ecord The model and serial numbers are located on the rear panel. ecord the model and serial numbers in the spaces provided

More information

PM-16 Personal Monitoring System. User Guide South D Street Fort Smith, AR

PM-16 Personal Monitoring System. User Guide South D Street Fort Smith, AR PM-16 Personal Monitoring System User Guide www.elitecoreaudio.com info@elitecoreaudio.com 920 South D Street Fort Smith, AR 72901 855-276-2673 i Important Safety Instructions WARNING: To ensure a long

More information

PREMIUMAUDIOVIDEOLIGHTINGANDPOWERPRODUCTS

PREMIUMAUDIOVIDEOLIGHTINGANDPOWERPRODUCTS FACTOR ELECTRONICS PREMIUMAUDIOVIDEOLIGHTINGANDPOWERPRODUCTS V-430 V-460 V-4120 V-4240 Commercial Mixer Amplifiers Owners Manual IMPORTANT NOTE: THIS OWNER'S MANUAL IS PROVIDED AS AN INSTALLATION AND OPERATING

More information

INFORMATION FOR YOUR SAFETY!

INFORMATION FOR YOUR SAFETY! INFORMATION FOR YOUR SAFETY! THE FCC REGULATION WARNING (for USA) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.

More information

i3speakers LX503 MK2 User Manual

i3speakers LX503 MK2 User Manual i3speakers LX503 MK2 User Manual Index Introduction 5 Precautions 6 Safety requirements 6 Caution servicing 7 EC Declaration of Conformity 7 Waste of Electrical and Electronic Equipment (WEEE) 7 Chapter

More information

4 Channel Frequency Conscious Noise Gate. Operation Manual

4 Channel Frequency Conscious Noise Gate. Operation Manual 4 Channel Frequency Conscious Noise Gate Operation Manual June 2005 This page has been left intentionally blank for your notes Page 2 CONTENTS 1.0 OVERVIEW 4 2.0 DESCRIPTION OF CONTROLS 5-7 2.1 Bypass

More information

Important Safety Information

Important Safety Information Owner's Manual Important Safety Information FCC Notice This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits

More information

A-16D A-Net Distributor

A-16D A-Net Distributor A-16D A-Net Distributor For use with the Personal Monitor Mixing System Information in this document is subject to change. All rights reserved. Copyright 2003 Aviom, Inc. Printed in USA Document Rev. 1.03

More information

CABINET POWERED MIXING CONSOLE

CABINET POWERED MIXING CONSOLE R SHS AUDIO SPMU- 00 CABINET POWERED MIXING CONSOLE USER'S MANUAL SAFETY INSTRUCTIONS SPECIFICATIONS Inputs Input modes Input Impedance Rated Input level Connector WARNING - TO REDUCE THE RISK OF FIRE

More information

AV30MX-2 Operation Manual

AV30MX-2 Operation Manual AV30MX-2 Operation Manual 1 Important safety instructions 1. Please read carefully prior to product installation or operation. 2. Read these instructions. 3. Keep these instructions. 4. Heed all warnings.

More information

PRE16/26 AUDAC PROFESSIONAL AUDIO EQUIPMENT. PRE16/26 6 Channel Pre-Amplifier Single/Double Output Zone. User Manual & Installation Guide

PRE16/26 AUDAC PROFESSIONAL AUDIO EQUIPMENT. PRE16/26 6 Channel Pre-Amplifier Single/Double Output Zone. User Manual & Installation Guide PRE16/26 AUDAC PROFESSIONAL AUDIO EQUIPMENT PRE16/26 6 Channel Pre-Amplifier Single/Double Output Zone User Manual & Installation Guide AUDAC PROFESSIONAL AUDIO EQUIPMENT User Manual & Installation Guide

More information

ZM 84 Audio Mixer. User Manual. Order code: CRAM41. Audio Mixer ZM 84 AUX 3 AUX 1 AUX 2 AUX 4 MASTER 1 MASTER 2 OFF BASS BASS TREBLE TREBLE BASS BASS

ZM 84 Audio Mixer. User Manual. Order code: CRAM41. Audio Mixer ZM 84 AUX 3 AUX 1 AUX 2 AUX 4 MASTER 1 MASTER 2 OFF BASS BASS TREBLE TREBLE BASS BASS ZM 84 Audio Mixer User Manual -20-10 0 +10 +20-20 -10 0 +10 +20 POWER L R 0 0 ON ZM 84 Audio Mixer AUX 4 MIC/LINE 1 MIC/LINE 1 MIC/LINE 2 MIC/LINE 3 MIC/LINE 4 THR THR +6 +10 +6 AUX 3 AUX 1 AUX 2 AUX 4

More information

a u d i o p h i l e p r e a m p l i f i e r user guide

a u d i o p h i l e p r e a m p l i f i e r user guide PRE32 a u d i o p h i l e p r e a m p l i f i e r user guide Welcome! Welcome to the Primare PRE32! Your PRE32 is a high-quality audiophile preamplifier, designed as the ideal centrepiece of a home hi-fi

More information

SR Series Crossovers. Owner s Manual SR 823 SR 834. A Harman International Company

SR Series Crossovers. Owner s Manual SR 823 SR 834. A Harman International Company SR Series Crossovers Owner s Manual SR 823 SR 834 A Harman International Company Warning For your protection, please read the following: These symbols are internationally accepted symbols that warn of

More information

a u d i o p h i l e i n t e g r a t e d a m p l i f i e r user guide

a u d i o p h i l e i n t e g r a t e d a m p l i f i e r user guide I22 a u d i o p h i l e i n t e g r a t e d a m p l i f i e r user guide Welcome! Welcome to the Primare I22! Your I22 is a high-quality integrated amplifier, designed as the ideal centrepiece of a home

More information

User Manual. ilive 2 Wireless microphone system

User Manual. ilive 2 Wireless microphone system User Manual ilive 2 Wireless microphone system Safety instructions When using this electronic device, basic precautions should always be taken, including the following: 1 Read all instructions before using

More information

RU210. Dual Multi-UHF Wireless System. Item ref: UK, UK User Manual. Version 1.0

RU210. Dual Multi-UHF Wireless System. Item ref: UK, UK User Manual. Version 1.0 RU210 Dual Multi-UHF Wireless System Item ref: 171.970UK, 171.971UK User Manual Version 1.0 Caution: Please read this manual carefully before operating Damage caused by misuse is not covered by the warranty

More information

NU2. Dual UHF Wireless System. Item ref: UK, UK, UK, UK User Manual. Version 1.0

NU2. Dual UHF Wireless System. Item ref: UK, UK, UK, UK User Manual. Version 1.0 NU2 Dual UHF Wireless System Item ref: 171.974UK, 171.975UK, 171.976UK, 171.977UK User Manual Version 1.0 Caution: Please read this manual carefully before operating Damage caused by misuse is not covered

More information

DMP40. User Manual.

DMP40. User Manual. DMP40 User Manual www.audac.eu ADDITIONAL INFORMATION This manual is put together with much care, and is as complete as could be on the publication date. However, updates on the specifications, functionality

More information

MIC MECHANIC 2. Ultra-Simple Battery-Powered Vocal Effects Stompbox with Echo, Reverb and Pitch Correction. User Manual

MIC MECHANIC 2. Ultra-Simple Battery-Powered Vocal Effects Stompbox with Echo, Reverb and Pitch Correction. User Manual MIC MECHANIC 2 Ultra-Simple Battery-Powered Vocal Effects Stompbox with Echo, Reverb and Pitch Correction User Manual 2 MIC MECHANIC 2 User Manual Important Safety Instructions Terminals marked with this

More information

MUSE : IP+POWER+RS-232 Transmitter

MUSE : IP+POWER+RS-232 Transmitter MUSE : IP+POWER+RS-232 Transmitter Welcome! Everyone at Altinex greatly appreciates your purchase of the MUSE Transmitter. We are confident that you will find it both reliable and simple to use. If you

More information

plifier D-501 otion Am Tactile M

plifier D-501 otion Am Tactile M Tactile Motion Amplifier D-501 IMPORTANT SAFETY INSTRUCTIONS WARNING: 1. Read and keep these instructions for future reference. 2. Do not use this apparatus near water. 3. Clean only with a dry cloth.

More information

RM4 MODULAR TUBE PREAMP OWNERS MANUAL

RM4 MODULAR TUBE PREAMP OWNERS MANUAL A M P L I F I E R S RM4 MODULAR TUBE PREAMP OWNERS MANUAL Dear Randall Owner, Congratulations on the purchase of your new Randall Amplifier, and thank you for the support of our product line. Randall amps

More information