General Specifications

Size: px
Start display at page:

Download "General Specifications"

Transcription

1 General Specifications GS 1C27H1-1EN EJX11B and EJX3B Diaphragm Sealed Differential Pressure and Gauge Pressure Transmitters Diaphragm seals are used to prevent process medium from entering directly into the -sensing assembly of the differential and transmitters, they are connected to the transmitter using capillaries filled with fill fluid. EJX11B Diaphragm Sealed Differential Pressure and EJX3B Diaphragm Sealed Gauge Pressure Transmitters can be used to measure liquid, gas, or steam flow, as well as liquid level, density and. EJX11B and EJX3B transmit not only process variables but also the setting parameters using wireless signal. The transmitters run on internal batteries, and the installation cost can be decreased since hard-wiring is not required. The communication protocol is compliant with ISA1.11a protocol specifications. FEATURES Long Life Battery Design Ultra low current consumption design using two high capacity lithium-thionyl chloride batteries provide wireless operation for years. Security Assured Wireless Network Joining Infrared communication between the devices for wireless network configuration and parameter setting. Quick Update Time Selectable from.5 second to 6 minutes for measured process value to publish wirelessly. STANDARD SPECIFICATIONS WIRELESS SPECIFICATIONS Wireless Communication Communication protocol: ISA1.11a protocol Data rate: 25 kbps Frequency: MHz license free ISM band Radio security: AES 12 bit codified RF Transmitter power: Max dbm (fixed) Antenna: +2 dbi Omni directional monopole type Separately sold remote antenna and antenna cables can be used. POWER SUPPLY SPECIFICATIONS Battery: Use the dedicated battery pack. Rated voltage: 7.2 V Rated capacity: 19 Ah SPAN AND RANGE LIMITS EJX11B Measurement Span/Range Span M Range Span H Range EJX3B kpa 2 to 1 1 to 1 1 to 5 5 to 5 inh 2 O(/D1) mbar(/d3) mmh 2 O(/D) to to to 2 2 to 2 2 to 1 1 to 1 1 to 5 5 to 5 Measurement Span and Range MPa psi (/D1) bar (/D2) A *1 Span.35 to to 5.35 to 35 Range.1 to to 5 1 to 35 Flush Span.16 to to to 16 B type *1 Range.1 to to 23 1 to 16 Extended Span.16 to 7 23 to to 7 type *1 Range.1 to to 1 1 to 7 *1: Measurement range is within the flange rating. 2 to 1 1 to 1.1 to 5 kgf/cm 2 5 to 5 kgf/cm 2 T1E.ai kgf/cm 2 (/D3).35 to 35 1 to to 16 1 to to 7 1 to 7 T2E.ai PERFORMANCE SPECIFICATIONS Zero-based calibrated span, linear output, wetted parts material code SW for 3-inch flange flush type, fill fluid code B, capillary length of 5 m, and in the continuous measurement mode. Specification Conformance EJX series ensures specification conformance to at least ±3σ. Reference Accuracy of Calibrated Span (includes terminal-based linearity, hysteresis, and repeatability) Yokogawa Electric Corporation , Nakacho, Musashino-shi, Tokyo, 1-75 Japan Tel.: Fax.: GS 1C27H1-1EN Copyright Feb th Edition June 217

2 EJX11B Measurement span Reference accuracy X X span X > span URL (upper range limit) Measurement span Reference accuracy X X span X > span URL (upper range limit) EJX3B Measurement span Reference accuracy X span X > span X URL (upper range limit) H ±.15% of Span ±( URL/span)% of Span 1 kpa ( inh 2 O) 5 kpa (2 inh 2 O) M ±.15% of Span ±( URL/span)% of Span 1 kpa ( inh 2 O) 1 kpa ( inh 2 O) A ±.15% of Span ±(.1+.5 URL/Span)% of Span.35 MPa (5 psi) 3.5 MPa (5 psi) B T3E.ai TE.ai 1.6 MPa (23 psi) 16 MPa (23 psi) T5E.ai Square Root Output Accuracy (EJX11B) The square root accuracy is a percent of flow span. Output Accuracy 5% or Greater Same as reference accuracy Reference accuracy 5 5% to Dropout point Square root output (%) Response Time EJX11B (Differential ) M and H capsule: 26 ms (approximate value at normal temperature) EJX3B 2 ms (approximate value at normal temperature) When software damping is set to zero and including dead time of 1 msec (nominal) Static Pressure Signal Range and Accuracy (EJX11B) (Includes terminal-based linearity, hysteresis, and repeatability) Range Upper Range Value and Lower Range Value of the statice can be set in the range between and Maximum Working Pressure (MWP*). The upper range value must be greater than the lower range value. Minimum setting span is.5 MPa (73 psi). *: Maximum Working Pressure (MWP) is within flange rating. Accuracy Absolute Pressure 1 MPa or higher : ±.2% of span Less than 1 MPa: ±.2% (1 MPa/span) of span Gauge Pressure Reference Gauge reference is 113 hpa (1 atm) Note : Gauge variable is based on the above fixed reference and thus subject to be affected by the change of atomospheric. 2 Ambient Temperature Effects per 2 C (5 F) Change EJX11B Capsule Effect M and H ±(.25% Span +.6% URL) EJX3B Capsule A and B Effect ±(.5% Span +.25% URL) Static Pressure Effects per.69 MPa (1 psi) Change (EJX11B) Span Effects : ±.2% of span Effect on Zero : ±.1% of URL Battery Characteristic Battery pack with long life lithium-thionyl chloride batteries. With the intrinsically safe type, the battery pack is replaceable in hazardous area. Typical battery life is 1 years at 6 seconds update time or years at 1 seconds update time in the following conditions.* Ambient temperature: 23±2 C Device role: IO mode LCD display: off * Environmental condition such as vibration may affect the battery life. All Rights Reserved. Copyright 29, Yokogawa Electric Corporation GS 1C27H1-1EN May 31, 213-

3 3 FUNCTIONAL SPECIFICATIONS Output Wireless (ISA1.11a protocol) 2. GHz signal. Output mode for EJX11B, linear or square root, is selectable. Update Time Measurement Differential Pressure mode Continuous 1 ms 1 ms.5 to 36 s.5 to 36 s Intermittent selectable selectable The transmitter shifts to the countinuous mode when the update time is set to.5 second. Zero Adjustment Limits Zero can be fully elevated or suppressed, within the lower and upper range limits of the capsule. External Zero Adjustment External zero is continuously adjustable with.1% incremental resolution of span. Integral Indicator (LCD display) 5-digit numerical display, 6-digit unit display and bar graph. The indicator is configurable to display one or up to three of the following variables periodically.; Differential, static, temperature. See also Factory Setting. Self Diagnostics Capsule failure, amplifier failure, configuration error, battery alarm, wireless communication alarm and over-range error for process variables. Software Download Function Software download function permits to update wireless field device software via ISA1.11a wireless communication. Battery Pack 2x primary lithium-thionyl chloride batteries With battery case (batteries sold separately) Capillary Fill Fluid Density Compensation Compensation of the zero shift by the ambient temperature effect on the capillary tube. NORMAL OPERATING CONDITION (Optional features or approval codes may affect limits.) Ambient Temperature Limits - to 6 C (- to 1 F) -3 to 6 C (-22 to 1 F) LCD visible range (Note: The ambient temperature limits must be within the fill fluid operating temperature range, see table 1.) Process Temperature Limits See table 1. Ambient Humidity Limits to 1% RH Working Pressure Limits See table 1. For atmospheric or below, see figure 1-1 and 1-2. All Rights Reserved. Copyright 29, Yokogawa Electric Corporation GS 1C27H1-1EN Feb. 1, 217-

4 Table 1. Process temperature, Ambient temperature, and Working Code Process temperature *1 Ambient temperature *2 Working Specific gravity *3 Silicone oil (general use) Silicone oil (general use) A B 1 to 25 C * (1 to 2 F) 3 to 1 C (22 to 356 F) 1 to 6 C (1 to 1 F) 15 to 6 C (5 to 1 F) 2.7 kpa abs (.3 psi abs) to flange rating Silicone oil (high temperature use) Fluorinated oil (oil-prohibited use) C D 1 to 31 C (5 to 59 F) 2 to 12 C ( to 2 F) 1 to 6 C (5 to 1 F) 1 to 6 C (1 to 1 F) 51 kpa abs (7. psi abs) to flange rating to 1.92 Ethylene glycol (low temperature use) E 5 to 1 C (5 to 212 F) to 6 C ( to 1 F) 1 kpa abs (atmospheric ) to flange rating 1.9 T6E.ai *1: See figure 1-1 and 1-2 Working Pressure and Process Temperature. *2: This ambient temperature is the transmitter ambient temperature. *3: Approximate values at a temperature of 25 C (77 F) *: In case of wetted parts material code TW (Tantalum), process temperature limit is up to 2 C (392 F). Note: The differential transmitter should be installed at least 6 mm below the high (HP) process connection. However, this value (6 mm) may be affected by ambient temperature, operating, fill fluid or material of the wetted diaphragm. Contact YOKOGAWA when the transmitter can not be installed at least 6 mm below the HP process connection. Transmitter ambient temperature range (for fill fluid code A, B) Process temperature for fill fluid code B Process temperature for fill fluid code A Process temperature for fill fluid code C Flange max. working Transmitter ambient temperature range (for fill fluid code D) Process temperature for fill fluid code E Process temperature for fill fluid code D Flange max. working Working kpa abs (psi abs) 1 (1.5) 1 (1.) Atmospheric 1 (1.5) 51 (7.) Working kpa abs (psi abs) 1(1.) Atmospheric 2.7 (.3) 2.7 (.3) 1(.1) 1 (.1).1(.1) Process Temperature ( C) F1E.ai Figure 1-1. Working Pressure and Process Temperature (Fill fluid : silicone oil for general and high temperature use).1(.1) Process Temperature ( C) F2E.ai Figure 1-2. Working Pressure and Process Temperature (Fill fluid : fluorinated oil for oil-prohibited use and ethylene glycol for low temperature use) All Rights Reserved. Copyright 29, Yokogawa Electric Corporation GS 1C27H1-1EN July 1, 212-

5 REGULATORY COMPLIANCE STATEMENTS This device contains the wireless module which satisfies the following standards. * Please confirm that an installation region fulfills an applicable standard. If additional regulatory information and approvals are required, contact a Yokogawa representative. EMC Conformity Standards EN Class A, Table 2 (For use in industrial locations), EN Radio Equipment Directive (RE) ETSI EN 3 32, ETSI EN , ETSI EN , EN611-1, EN , EN62311 Indoor/Outdoor use European Pressure Equipment Directive 21/6/EU Sound Engineering Practice EU RoHS Directive EN551 Safety Requirement Standards EN611-1, EN Installation category: I (Anticipated transient overvoltage 33 V) Pollution degree: 2 Indoor/Outdoor use Regulation Conformity of the Wireless Module FCC Approval IC Approval PHYSICAL SPECIFICATIONS Process connections See the following table. Table 2. Flange size and rating Process connection style Flush type Extended type Combination type (Extended and Flush)* 3 -inch 3-inch Size 3-inch 2-inch 1 1/2 -inch* 1 High side: -inch Low side: 3-inch Flange JIS 1K, 2K, K, 63K* 2 ANSI Class 15, 3, 6 JPI Class 15, 3, 6 DIN PN1/16, 25/, 6 JIS 1K, 2K, K* 2 ANSI Class 15, 3 JPI Class 15, 3 DIN PN1/16, 25/ JIS 1K, 2K ANSI Class 15, 3 JPI Class 15, 3 DIN PN1/16, 25/ *1: Flushing connection rings are always attached. *2: Applicable for EJX3B only. *3: Applicable for EJX11B only. Gasket Contact Surface See the following table. Table 3. Gasket contact surface Wetted parts material code Gasket contact Surface Flange JIS/JPI/DIN SW, SE, SY HW, TW, UW SW, SE, SY ANSI T7E.ai HW, TW, UW Serration *1 Flat (No serration) : Applicable, : Not applicable *1: ANSI B16.5 TE.ai 5 Electrical Connections See MODEL AND SPECIFICATIONS. Transmitter Mounting 2-inch pipe mounting Wetted Parts Material Diaphragm seal Diaphragm and other wetted parts; Refer to MODEL AND SUFFIX CODES. Flushing connection ring (optional) Ring and Vent / Drain plugs; Refer to MODEL AND SUFFIX CODES. (Spiral) gasket for transmitter side 316 SST (Hoop), PTFE Teflon (Filler) Non-wetted Parts Material Transmitter body section: Cover flange ASTM CF-M Cover flange bolting B7 carbon steel, 316L SST, or 66 SST Housing Low copper cast aluminum alloy Coating of housing [for aluminum housing] Urethane curing type polyester resin powder coating Mint-green paint (Munsell 5.6BG 3.3/2.9 or its equivalent) [for option code /P or /X2] Epoxy and polyurethane resin solvent coating Degrees of Protection IP66/IP67, NEMAX Name plate and tag 316 SST tag plate wired onto transmitter Diaphragm seal section: Process Flange JIS S25C, 3 SST, or 316 SST Capillary tube 316 SST Protection tube 3 SST PVC-sheathed (Max. operating temperature of PVC,1 C (212 F)) Fill fluid See table 1. Weight EJX11B Flush type: 1.2 kg (.1 lbs) (3-inch ANSI Class15 flange, capillary length 5 m; without integral indicator and mounting bracket.) Extended type: 23. kg (52.5 lbs) (-inch ANSI Class15 flange, extention length (X 2 )=1 mm, capillary length 5 m; without integral indicator and mounting bracket.) Combination type: 21. kg (6.3 lbs) (-inch and 3-inch ANSI Class15 flange, extention length (X 2 ) =1 mm, capillary length 5 m; without integral indicator and mounting bracket.) All Rights Reserved. Copyright 29, Yokogawa Electric Corporation GS 1C27H1-1EN June

6 EJX3B Flush type: 9.2 kg (2.3 lbs) (3-inch ANSI Class 15 flange, capillary length 5 m; without integral indicator and mounting bracket.) Extended type: 1.3 kg (31.5 lbs) (-inch ANSI Class 15 flange, extention length (X 2 )=1 mm, capillary length 5 m; without integral indicator and mounting bracket.) < Related Instruments> Field Wireless System: Refer to GS 1W1A1-1EN Field Wireless Management Station YFGW1: GS 1W2D1-1EN Field Wireless Access Point YFGW51: GS 1W2E1-1EN Field Wireless Media Converter YFGW61: GS 1W2D2-1EN 6 MODEL AND SUFFIX CODES Instruction The model and suffix codes for EJX11B and EJX3B consist of two parts; a transmitter body section (I) and a diaphragm seal section (II). This specification sheet introduces these two parts separately. The transmitter body section is shown in one table, and the diaphragm seal section specifications are listed according to the process connection style. First select the model and suffix codes of transmitter body section and then continue on one of the diaphragm seal section. EJX11B EJX3B I Transmitter body section II Diaphragm seal section F3E.ai I. Transmitter body section EJX11B EJX3B Model EJX11B EJX3B Output signal Measurement span (capsule) Suffix codes L Description Diaphragm sealed differential transmitter Diaphragm sealed Gauge Pressure transmitter Wireless communication (ISA1.11a protocol) M * to 1 kpa ( to inh 2 O) H * to 5 kpa ( to 2 inh 2 O) A * to 3.5 MPa (5 to 5 psi) B * to 16 MPa (23 to 23 psi) *1 S C Coverflange bolts and nuts material Installation Amplifier housing J G C Always S Always C B7 carbon steel 316L SST 66 SST Horizontal piping type and left side high Cast aluminum alloy with detachable antenna (2 dbi) * Cast aluminum alloy without antenna (N connector) **5 Electrical connection Integral Indicator Mounting braket Diaphragm seal section J No electrical connection, battery-powered type (battery case only; battery cells not included) D Digital indicator B N SST 2-inch pipe mounting, flat type (for horizontal piping) None Continued on diaphragm seal section (II) T9E.ai The marks indicate the most typical selection for each specification. *1: When specified process connection style code E, maximum range and span are 7 MPa (1 psi.) *2: Applicable for EJX11B *3: Applicable for EJX3B *: Order the antenna separately from accessary option. *5: Remote antenna cables can be attached. Order separately from accessary option. All Rights Reserved. Copyright 29, Yokogawa Electric Corporation GS 1C27H1-1EN Feb. 1, 217-

7 7 II. Diaphragm seal section (Flush type) Precess connection size: 3-inch ( mm) / 2-inch (5 mm) EJX11B EJX3B W 3 2 Model EJX11B EJX3B Process connection style Flange rating Process connection size (Process flange size) Flange material Gasket contact surface *1 Wetted parts material *1 Flushing connection ring *2 Extension Fill fluid Suffix codes Transmitter body section (I) Description -W Flush type J JIS 1K J JIS 2K J JIS K J JIS 63K A ANSI class 15 P JPI class 15 A ANSI class 3 P JPI class 3 A ANSI class 6 P JPI class 6 D DIN PN1/16 D DIN PN25/ D DIN PN A B C A B A B C D E inch ( mm) 2-inch (5 mm) JIS S25C 3 SST * SST *11 Serration (for ANSI flange with wetted parts material SW only) Flat (no serration) [Diaphragm] [Others] SW L SST 316L SST HW Hastelloy C-276 *9# Hastelloy C-276 *9# TW Tantalum *7 Tantalum *7 UW Titanium Titanium [Ring] [Vent/Drain plugs] [Material] None Straight type R 1/ connections * 316 SST # Straight type 1/ NPT connections 316 SST # Straight type R 1/ connections * 316 SST # Straight type 1/ NPT connections 316 SST # None [Process temp.] [Ambient temp.] For general use (silicone oil) *3 1 to 25 C 1 to 6 C For general use (silicone oil) 3 to 1 C 15 to 6 C For high temperature use (silicone oil) * *7 1 to 31 C 1 to 6 C For oil-prohibited use (fluorinated oil) *5 2 to 12 C 1 to 6 C For low temperature use (ethylene glycol) 5 to 1 C to 6 C EJX11B EJX3B Capillary connection Capillary length *6 A Side of diaphragm seal unit Always 2 1 m m 2 m m 3 m m m m 5 m A m Option codes / Optional specification T1E.ai The marks indicate the most typical selection for each specification. Example: EJX11B-LMSCG-9JDN-WA13B1SW-BA25/ EJX3B-LASCG-9JDN-WA13B1SW-BA25/ *1: See table 3 Gasket contact surface. *2: When specified flushing connection ring code 1, 2, A, or B, exclusive gasket is provided for transmitter side. *3: In case of wetted parts material code TW (Tantalum), the process temperature limit is 1 to 2 C. *: Wetted parts material code TW (Tantalum) cannot be applied. *5: Even in case where fill fluid code D (fluorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing and dehydrating treatment for the wetted parts is required, specify option code K1 or K5. *6: In case of wetted parts material code HW (Hastelloy C), TW (Tantalum), and UW (Titanuym) for 2-inch flange, specify capillary length from 1 to 5 m. *7: Not applicable for flashing connection ring code 1 and 2. *: Not applicable for gasket contact surface code 1. *9: Hastelloy C-276 or N1276. *1: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user s process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (15 C [32 F] or above). Contact Yokogawa for detailed information of the wetted parts material. *11: Forged version of the material may be used. The # marks indicate the construction materials conform to NACE material recommendations per MR175/ISO Please refer to the latest standards for details. Selected materials also conform to NACE MR13. All Rights Reserved. Copyright 29, Yokogawa Electric Corporation GS 1C27H1-1EN Feb. 1, 217-

8 II. Diaphragm seal section (Flush type) Precess connection size: 1 1/2-inch ( mm) EJX11B EJX3B W Model EJX11B EJX3B Process connection style Flange rating Process connection size (Process flange size) Flange material Gasket contact surface *1 Wetted parts material *5 Flushing connection ring *2 Extension Fill fluid Suffix codes W J J J A A A P P P A B C SW C D A B D E Transmitter body section (I) Flush type JIS 1K JIS 2K JIS K ANSI class 15 ANSI class 3 ANSI class 6 JPI class 15 JPI class 3 JPI class 6 1 1/2-inch ( mm) JIS S25C 3 SST *6 316 SST *6 Description Serration (for ANSI flange only) Flat (no serration) [Diaphragm] [Others] 316L SST 316L SST [Ring] [Vent/Drain plugs] [Material] Reducer type R 1/ connections * 316 SST # Reducer type 1/ NPT connections 316 SST # Reducer type R 1/ connections * 316 SST # Reducer type 1/ NPT connections 316 SST # None [Process temp.] [Ambient tempe.] For general use (silicone oil) 1 to 25 C 1 to 6 C For general use (silicone oil) 3 to 1 C 15 to 6 C For oil-prohibited use (fluorinated oil) *3 2 to 12 C 1 to 6 C For low temperature use (ethylene glycol) 5 to 1 C to 6 C EJX11B EJX3B Capillary connection Capillary length Option codes A Side of diaphragm seal unit Always 2 1 m m 2 m m 3 m m m m 5 m A m / Optional specification The marks indicate the most typical selection for each specification. Example: EJX11B-LMSCG-9JDN-WA1B1SW-BA25/o EJX3B-LASCG-9JDN-WA1B1SWD-BA25/o *1: See table 3 Gasket contact surface. *2: When specified flushing connection ring code 3,, C, or D, exclusive gasket is provided for transmitter side. *3: Even in case where fill fluid code D (fluorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing and dehydrating treatment for the wetted parts is required, specify option code K1 or K5. *: Not applicable for gasket contact surface code 1. *5: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user s process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (15 C [32 F] or above). Contact Yokogawa for detailed information of the wetted parts material. *6: Forged version of the material may be used. T11E.ai All Rights Reserved. Copyright 29, Yokogawa Electric Corporation GS 1C27H1-1EN Feb. 1, 217-

9 9 II. Diaphragm seal section (Extended type) Precess connection size: -inch (1 mm) / 3-inch ( mm) EJX11B EJX3B E 3 Model EJX11B EJX3B Process connection style Flange rating Process connection size (Process flange size) Flange material Flushing connection ring Extension Fill fluid Capillary connection Capillary length *3 Suffix codes E J J J A A P P D D A B C Gasket contact surface * Option codes A B C D E B Transmitter body section (I) Extended type JIS 1K JIS 2K JIS K ANSI class 15 ANSI class 3 JPI class 15 JPI class 3 DIN PN1/16 DIN PN25/ -inch (1 mm) 3-inch ( mm) JIS S25C 3 SST *5 316 SST *5 Serration (for ANSI flange only) Flat (no serration) Description Wetted parts material * [Diaphragm] [Pipe] [Others] SE L SST 316 SST 316 SST None Length (X2) = 5 mm Length (X2) = 5 mm Length (X2) = 1 mm Length (X2) = 1 mm Length (X2) = 15 mm Length (X2) = 15 mm [Process temp.] [Ambient temp.] For general use (silicone oil) 1 to 25 C 1 to 6 C For general use (silicone oil) 3 to 1 C 15 to 6 C For high temperature use (silicone oil) 1 to 31 C 1 to 6 C For oil-prohibited use (fluorinated oil) *2 2 to 12 C 1 to 6 C For low temperature use (ethylene glycol) 5 to 1 C to 6 C Back of diaphragm seal unit Always 2 1 m m 2 m m 3 m m m m 5 m A m / Optional specification The marks indicate the most typical selection for each specification. Example: EJX11B-LMSCG-9JDN-EA1B1SE2-BB25/o EJX3B-LASCG-9JDN-EA1B1SE1-BB25/o *1: See table 3 Gasket contact surface. *2: Even in case where fill fluid code D (fluorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing and dehydrating treatment for the wetted parts is required, specify option code K1 or K5. *3: The specified capillary length includes the extension length (X 2 ) and the flange thickness (t). *: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user s process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (15 C [32 F] or above). Contact Yokogawa for detailed information of the wetted parts material. *5: Forged version of the material may be used. EJX11B EJX3B T12E.ai All Rights Reserved. Copyright 29, Yokogawa Electric Corporation GS 1C27H1-1EN Feb. 1, 217-

10 1 II. Diaphragm seal section (Combination type) Precess connection size: High side; -inch (1 mm) Extended type Low side; 3-inch ( mm) Flush type EJX11B Y W Model Suffix codes Description EJX11B Process connection style Y Transmitter body section (I) Combination type (Extended and Flush) Flange rating J JIS 1K J JIS 2K A ANSI class 15 A ANSI class 3 P JPI class 15 P JPI class 3 D DIN PN1/16 D DIN PN25/ Process connection size (Process flange size) Flange material Gasket contact surface *1 W A B C High side -inch (1 mm) Low side 3-inch ( mm) JIS S25C 3 SST *5 316 SST *5 Serration (for ANSI flange only) Flat (no serration) Wetted parts material * [Diaphragm] [Pipe] [Others] SY High side: 316L SST 316 SST 316 SST Low side: 316L SST 316L SST Flushing connection ring Extension None Length (X2) = 5 mm Length (X2) = 1 mm Length (X2) = 15 mm Fill fluid [Process [Ambient temperature] temperature] Capillary connection Capillary length *3 Option codes -A B C D E C For general use (silicone oil) 1 to 25 C 1 to 6 C For general use (silicone oil) 3 to 1 C 15 to 6 C For high temperature use (silicone oil) 1 to 31 C 1 to 6 C For oil-prohibited use (fluorinated oil) *2 2 to 12 C 1 to 6 C For low temperature use (ethylene glycol) 5 to 1 C to 6 C High side: Back of diaphragm seal unit Low side: Side of diaphragm seal unit Always 2 1 m m 2 m m 3 m m m m 5 m A m / Optional specification The marks indicate the most typical selection for each specification. Example: EJX11B-LMSCG-9JDN-YA1WB1SY1-BC25/o *1: See table 3 Gasket contact surface. *2: Even in case where fill fluid code D (fluorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing and dehydrating treatment for the wetted parts is required, specify option code K1 or K5. *3: The specified capillary length of high side (extended side) includes the extension length (X 2 ) and the flange thickness (t). *: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user s process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (15 C [32 F] or above). Contact Yokogawa for detailed information of the wetted parts material. *5: Forged version of the material may be used. T13E.ai All Rights Reserved. Copyright 29, Yokogawa Electric Corporation GS 1C27H1-1EN Feb. 1, 217-

11 11 OPTIONAL SPECIFICATIONS (For Explosion Protected type) Item Description Code Factory Mutual (FM) ATEX Canadian Standards Association (CSA) IECEx FM Intrinsically safe Approval Applicable Standard: Class 36, Class 361, Class 3611, Class 31, NEMA 25, ANSI/ISA-679-, ANSI/ISA Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1, Groups E, F & G and Class III, Division 1, Class I, Zone, in Hazardous Locations, AEx ia IIC Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division 2, Groups F & G and Class III, Division 1, Class I, Zone 2, Group IIC, in Hazardous Locations Enclosure: NEMA X, Temp. Class: T, Amb. Temp.: 5 to 7 C (5 to 15 F) ATEX Intrinsically safe Approval Applicable Standard: EN679-, EN679-11, EN Certificate: KEMA 1ATEX16 X II 1 G Ex ia IIC T Ga Degree of protection: IP66/IP67 Maximum Process Temp.(Tp):12 C(2 F) Amb. Temp.(Tamb): 5 to 7 C (5 to 15 F) CSA Intrinsically safe Approval Certificate: Applicable standard: CAN/CSA-C22.2 No., CAN/CSA-C22.2 No.., C22.2 No.25, CAN/CSA-C22.2 No.9,CAN/CSA-C22.2 No.157, C22.2 No.213, CAN/CSA-C22.2 No.611-1, CAN/CSA-C22.2 No.679-, CAN/CSA-E679-11, IEC6529 Ex ia IIC T Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1, Groups E, F & G, Class III, Division 1. Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division 2, Groups F & G, Class III, Division 1 Enclosure: IP66/IP67 and Type X Temperature Code: T Maximum Process Temp.(Tp):12 C (2 F) Amb. Temp.(Tamb): 5 to 7 C (5 to 15 F) IECEx Intrinsically safe Approval Applicable Standard: IEC679-:211, IEC679-11:211, IEC679-26:26 Certificate: IECEx KEM 1.7 X Ex ia IIC T Ga Enclosure: IP66/IP67 Maximum Process Temp.(Tp) :12 C(2 F) Amb. Temp.(Tamb): 5 to 7 C (5 to 15 F) FS17 KS27 CS17 SS27 All Rights Reserved. Copyright 29, Yokogawa Electric Corporation GS 1C27H1-1EN Jan. 1, 21-

12 12 OPTIONAL SPECIFICATIONS Item Description Code Painting Color change Amplifier cover only P Coating change Anti-corrosion coating *1 X2 Oil-prohibited use Degrease cleansing treatment K1 Oil-prohibited use with dehydrating treatment Degrease cleansing treatment and dehydrating treatment K5 Calibration units *3 P calibration (psi unit) D1 (See table for Span and bar calibration (bar unit) D3 Range Limits.) M calibration (kgf/cm 2 unit) D Teflon film *2 *7 Diaphragm protection from sticky process fluid by FEP Teflon film attached with fluorinated oil. Operation range: 2 to 15 C, to 2 MPa (Not applicable for vacuum service). TF1 Operating temperature correction * Adjusting range: C to Maximum temperature of specified fill fluid R Capillary without PVC sheaths When ambient temperature exceeds 1 C, or use of PVC is prohibited V Gold-plated diaphragm *5 Inside of isolating diaphragms (fill fluid side) are gold plated, effective for hydrogen permeation. A1 Process flange, Block M2W For Flush type Process flange, Block, Ring *6 M5W Material certificate Process flange, Block, Pipe, Base For Extended type M2E High Pressure side: Process flange, Block, Pipe, Base *12 Low Pressure side: Process flange, Block For Combination type M2Y (Flange rating) (Test ) JIS 1K 2 MPa (29 psi) T51 JIS 2K 5 MPa (72 psi) T5 EJX11B JIS K * 1 MPa (15 psi) T57 ANSI/JPI Class 15 3 MPa (3 psi) T52 ANSI/JPI Class 3 * MPa (116 psi) T56 ANSI/JPI Class 3 *9 7 MPa (1 psi) T55 ANSI/JPI Class 6 * 16 MPa (23 psi) T5 JIS 1K 2 MPa (29 psi) T51 Pressure test/ JIS 2K, K, 63K 3.5 MPa (5 psi) T53 Leak test ANSI/JPI Class 15 3 MPa (3 psi) Nitrogen (N 2 ) Gas *1 T52 Certificate *11 Retention time: ANSI/JPI Class 3, MPa (5 psi) 1 minutes T53 JIS 1K 2 MPa (29 psi) T51 JIS 2K 5 MPa (72 psi) T5 EJX3B JIS K * 1 MPa (15 psi) T57 JIS K *9 7 MPa (1 psi) T55 JIS 63K * 16 MPa (23 psi) T5 ANSI/JPI Class 15 3 MPa (35 psi) T52 ANSI/JPI Class 3 * MPa (116 psi) T56 ANSI/JPI Class 3 *9 7 MPa (1 psi) T55 ANSI/JPI Class 6 * 16 MPa (23 psi) T5 *1: Not applicable with color change option. *2: Applicable for flush type (process connection style code W.) *3: The unit of MWP (Max. working ) on the name plate of a housing is the same unit as specified by option code D1, D3, and D. *: Specify the process operating temperature for zero correction. Example: Zero correction by process temperature 9 C. *5: Applicable for wetted parts material code SW, SE, SY, and HW. *6: Applicable for flushing connection ring code 1, 2, 3,, A, B, C, and D. *7: Applicable for flushing connection ring code. *: Applicable for flush type (process connection style code W.) *9: Applicable for extended type and Combination type (process connection style code E and Y.) *1: Pure nitrogen gas is used for oil-prohibited use (option code K1 and K5.) *11: The unit on the certificate is always MPa regardless of selection of option code D1, D3, or D. A flushing connection ring will not be applied when conducting the test or leak test. *12: Applicable for model EJX11B. For A-Capsule For B-Capsule All Rights Reserved. Copyright 29, Yokogawa Electric Corporation GS 1C27H1-1EN July 1, 212-

13 13 OPTIONAL ACCESSORIES Product Part number Specification Battery pack assembly F9915NQ* 1 Battery case, Lithium-thionyl chloride batteries 2 pieces Batteries* 2 F9915NR Lithium-thionyl chloride batteries, 2 pieces Battery case F9915NK* 3 Battery case only Remote antenna cable F9915KU 3 m with mounting bracket F9915KV 13 m (3 m+1 m), with arrester and mounting bracket Antenna F9915KW 2 dbi standard antenna F9915KY 6 dbi high gain antenna* *1: If you need F9915MA, please purchase F9915NQ. F9915NQ is a set of F9915MA and instruction manual. *2: Alternatively, Tadiran SL-27/S or TL-593/S batteries can be purchased from your local distributor. *3: If you need F9915NS, please purchase F9915NK. F9915NK is a set of F9915NS and instruction manual. *: Use of high gain antenna is limited by local regulation of radio and telecommunication law. Consult Yokogawa for details. All Rights Reserved. Copyright 29, Yokogawa Electric Corporation GS 1C27H1-1EN June 13, 217-

14 DIMENSIONS <Transmitter body section> (Amplifier housing code ) For EJX11B Unit: mm (approx. inch) For EJX3B 1 <Diaphragm seal section> (O. D. 6 mm) Flush type No ring (Flushing connection ring code ) With ring (EJX11B: Flushing connection ring code 1, 2, 3, and ) (EJX3B: Flushing connection ring code A, B, C, and D) n-øh f *3* t 25 *1 (.9) ød *2 ød øc øg ød øc * 122 (.) 191 (7.52) 2 (.9) 1 (1.61) Zero adjustment Integral indicator 39 (1.5) 6 (2.52) A* 7 * For electrical connection code 5, 9, A, and D 53* (2.7) 11 (7.13) 1 (5.51) 211 (.31) 39*7 (15.35) Ø11 (.33) Ground terminal 91 (3.5) Open to atmosphere Ø5 (.2) 6 (.2) 76 (2.99) 12 (.) 7 (1.5) Diaphragm seal Flushing *5 connection ring t j *1 f *3* k (.1) ød *2 øg 115 (.53) Mounting bracket (Flat-type, optional) 2-inch pipe High side Low side High side Low side Capillary length n-øh Vent/Drain plug Capillary length *1: When wetted parts material code UW (titanium), value is 3 (1.3). *2: Indicates inside diameter of gasket contact surface *3: In case where process flange material is JIS S25C, value of f is. *: In case where process flange material is JIS SUS3 in ANSI/JPI flange, value of f is included in t. *5: Flushing connection ring Straight type Reducer type Spiral gasket ød Spiral gasket ø For flange size 3 or 2 inch For flange size 1 1/2 inch *6: When option code K1 or K5 is selected, add 11 mm (.2 inch). *7: When amplifier housing code 9 is selected, the value is 27 mm (1.63 inch). In this case, the figure is shown as A. *: When amplifier housing code 9 is selected, the value is 1 mm (16.1 inch). In this case, the figure is shown as A. FE.ai All Rights Reserved. Copyright 29, Yokogawa Electric Corporation GS 1C27H1-1EN Feb. 1, 217-

15 * t *. <<Contents>> <<Index>> 15 Unit: mm (approx. inch) Extended type Extension length (X2) X ) 1 ( ød øc øg øa Extension code 2 6 X2 5(1.97) 1(3.9) 15(5.91) ( ). ø3 (ø1.1) f 3 n-øh Capillary length *1 Combination type for EJX11B n-øh ) 1 (. ød øc øg øa t X ) 1 (. n-øh f *3* t 25 (.9) ød *2 f*3* ø D ø C ø g ø3 (ø1.1) Capillary length *1 Capillary length High side Low side F5E.ai *1: The specified capillary length includes the extension length (X 2 ) and the flange thickness (t). *2: Indicates inside diameter of gasket contact surface. *3: In case where process flange material is JIS S25C, value of f is. *: In case where process flange material is 3 SST in ANSI/JPI flange, value of f is included in t. All Rights Reserved. Copyright 29, Yokogawa Electric Corporation GS 1C27H1-1EN July 1, 212-

16 16 Process flange size: inch (1 mm) Code Flange rating J1 J2 A1 A2 P1 P2 D2 D ød øc JIS 1K JIS 2K 21 (.27) 225 (.6) 175 (6.9) 15 (7.2) ANSI class (9.) 19.5 (7.5) ANSI class 3 25 (1.) 2.2 (7.) JPI class 15 JPI class (9.2) 19.5 (7.5) 25 (1.) 2.2 (7.) DIN PN1/16 DIN PN25/ 22 (.66) 235 (9.25) 1 (7.9) 19 (7.) øg 155 (6.1) 155 (6.1) 155 (6.1) 155 (6.1) 155 (6.1) 155 (6.1) 155 (6.1) 155 (6.1) ød t 1 (.71) 2 (.9) 23.9 (.9) 31. (1.25) 2 (.9) 32 (1.26) 2 (.79) 2 (.9) *3 * f 1.6 (.6) 1.6 (.6) 1.6 (.6) 1.6 (.6) No.(n) Bolt holes Dia.(øh) 19 (.75) 23 (.91) 19.1 (.75) 22. (.) 19 (.75) 22 (.7) 1 (.71) 22 (.7) j Unit: mm (Approx.: inch) k øa 96±.5 (3.7±.2) 96±.5 (3.7±.2) 96±.5 (3.7±.2) 96±.5 (3.7±.2) 96±.5 (3.7±.2) 96±.5 (3.7±.2) 96±.5 (3.7±.2) 96±.5 (3.7±.2) Process flange size: 3 inch ( mm) Code Flange rating J1 J2 J A1 A2 A P1 P2 P D2 D D5 JIS 1K JIS 2K JIS K ANSI class 15 ANSI class 3 ANSI class 6 JPI class 15 JPI class 3 JPI class 6 DIN PN1/16 DIN PN25/ DIN PN6 ød 15 (7.2) 2 (7.7) 21 (.27) øc 15 (5.91) 16 (6.3) 17 (6.69) 152. (6.) 19.5 (7.5) 29.6 (.25) 16.1 (6.62) 29.6 (.25) 16.1 (6.62) 19 (7.) 152. (6.) 21 (.27) 16.1 (6.61) 21 (.27) 16.1 (6.61) 2 (7.7) 16 (6.3) 2 (7.7) 16 (6.3) 215 (.6) 17 (6.69) Process flange size: 2 inch (5 mm) Code Flange rating J1 J2 J A1 A2 A P1 P2 P D2 D D5 JIS 1K JIS 2K JIS K ANSI class 15 ANSI class 3 ANSI class 6 JPI class 15 JPI class 3 JPI class 6 DIN PN1/16 DIN PN25/ DIN PN6 ød 155 (6.1) 155 (6.1) 165 (6.5) øc 12 (.72) 12 (.72) 13 (5.12) 12.7 (.75) 152. (6.) (6.5) 127. (5.) (6.5) 127. (5.) 152 (5.9) 12.6 (.75) 165 (6.5) 127. (5.) 165 (6.5) 127. (5.) 165 (6.5) 125 (.92) 165 (6.5) 125 (.92) 1 (7.9) 135 (5.31) øg 13 (5.12) 13 (5.12) 13 (5.12) 13 (5.12) 13 (5.12) 13 (5.12) 13 (5.12) 13 (5.12) 13 (5.12) 13 (5.12) 13 (5.12) 13 (5.12) øg 1 (3.9) 1 (3.9) 1 (3.9) 1 (3.9) 1 (3.9) 1 (3.9) 1 (3.9) 1 (3.9) 1 (3.9) 1 (3.9) 1 (3.9) 1 (3.9) ød *2 9 (3.5) 9 (3.5) 9 (3.5) 9 (3.5) 9 (3.5) 9 (3.5) 9 (3.5) 9 (3.5) 9 (3.5) 9 (3.5) 9 (3.5) 9 (3.5) ød *2 61 (2.) 61 (2.) 61 (2.) 61 (2.) 61 (2.) 61 (2.) 61 (2.) 61 (2.) 61 (2.) 61 (2.) 61 (2.) 61 (2.) t 1 (.71) 22 (.7) 32 (1.26) 23.9 (.9) 2.5 (1.12) 3.2 (1.5) 2 (.9) 2.5 (1.12) 3. (1.51) 2 (.79) 2 (.9) 2 (1.1) t 16 (.63) 1 (.71) 26 (1.2) 19.1 (.75) 22. (.) 31. (1.25) 19.5 (.77) 22. (.) 31.9 (1.26) 1 (.71) 2 (.79) 26 (1.2) *3 * f 1.6 (.6) 1.6 (.6) 6. (.25) 1.6 (.6) 1.6 (.6) 6. (.25) *3 * f 1.6 (.6) 1.6 (.6) 6. (.25) 1.6 (.6) 1.6 (.6) 6. (.25) No.(n) No.(n) Bolt holes Dia.(øh) 19 (.75) 23 (.91) 23 (.91) 19.1 (.75) 22. (.) 22. (.) 19 (.75) 22 (.7) 22 (.7) 1 (.71) 1 (.71) 22 (.7) Bolt holes Dia.(øh) 19 (.75) 19 (.75) 19 (.75) 19.1 (.75) 19.1 (.75) 19.1 (.75) 19 (.75) 19 (.75) 19 (.75) 1 (.71) 1 (.71) 22 (.7) j *1 25 (.9) 25 (.9) 25 (.9) 25 (.9) 25 (.9) 25 (.9) 25 (.9) 25 (.9) 25 (.9) 25 (.9) 25 (.9) 25 (.9) j 25 (.9) 25 (.9) 25 (.9) 25 (.9) 25 (.9) 25 (.9) 25 (.9) 25 (.9) 25 (.9) 25 (.9) 25 (.9) 25 (.9) k k øa 71±.5 (2.±.2) 71±.5 (2.±.2) 71±.5 (2.±.2) 71±.5 (2.±.2) 71±.5 (2.±.2) 71±.5 (2.±.2) 71±.5 (2.±.2) 71±.5 (2.±.2) Process flange size: 1 1/2 inch ( mm) Code Flange rating J1 J2 J A1 A2 A P1 P2 P JIS 1K JIS 2K JIS K ANSI class 15 ANSI class 3 ANSI class 6 JPI class 15 JPI class 3 JPI class 6 ød 1 (5.51) 1 (5.51) 16 (6.3) 127 (5.) øc 15 (.13) 15 (.13) 12 (.72) 9.6 (3.) 155. (6.12) 11.3 (.5) 155. (6.12) 11.3 (.5) 127 (5.) 9.6 (3.) 155 (6.1) 11.3 (.5) 155 (6.1) 11.3 (.5) øg 6 (3.39) 6 (3.39) 6 (3.39) 6 (3.39) 6 (3.39) 6 (3.39) 6 (3.39) 6 (3.39) 6 (3.39) ød *2 (1.73) (1.73) (1.73) (1.73) (1.73) (1.73) (1.73) (1.73) (1.73) t 16 (.63) 1 (.71) 2 (.9) 17.5 (.69) 2.6 (.1) 2. (1.13) 17.6 (.69) 2.6 (.1) 2.9 (1.1) *3 * f 1.6 (.6) 1.6 (.6) 6. (.25) 1.6 (.6) 1.6 (.6) 6. (.25) No.(n) Bolt holes Dia.(øh) 19 (.75) 19 (.75) 23 (.91) 15.9 (.63) 22. (.) 22. (.) 16 (.63) 22 (.7) 22 (.7) j k 3 (1.1) 3 (1.1) 3 (1.1) 3 (1.1) 3 (1.1) 3 (1.1) 3 (1.1) 3 (1.1) 3 (1.1) *1: When wetted parts material code UW (titanium) is selected, value is 3 (1.3). *2: Indicates inside diameter of gasket contact surface. *3: In case where process flange material is JIS S25C, value of f is. *: In case where process flange material is 3 SST in ANSI/JPI flange, value of f is included in t. T1E.ai All Rights Reserved. Copyright 29, Yokogawa Electric Corporation GS 1C27H1-1EN July 1, 212-

17 17 Antenna/Cable Non-directional antenna Gain: 2 dbi Gain: 6 dbi Part number: F9915KW Part number: F9915KY Antenna cable Sheath diameter: 11.2 mm < Without arrester > Part number: F9915KU Unit: mm (approx. inch) < With arrester > Part number: F9915KV 13 (5.12) Ø1 (Ø.55) Antenna 19 (.75) Ø21 (Ø.3) 5 (19.69) Ø22 (Ø.7) Antenna Cable 2 Length: 1 m Arrester Cable 1 Length: 3 m Cable 1 Length: 3 m 25 (.9) Ø26 (Ø1.2) Transmitter body Transmitter body Antenna mounting bracket 1 (.69) 17 (.67) 72 (2.3) 6 (2.6) 2 dbi antenna 272 (1.71) *1 135 (5.31) (3.6) 9 (3.6) 2-inch pipe (O.D. 6.5 mm) *1: When 6 dbi antenna is selected, the value is 62 mm (25.2 inch). F6E.ai All Rights Reserved. Copyright 29, Yokogawa Electric Corporation GS 1C27H1-1EN July 19, 216-

18 1 Infrared Configuration Infrared port F7E.ai <Ordering Information> Specify the following when ordering 1. Model, suffix codes, and option codes 2. Calibration range and unit 1) Range Calibration range can be specified with range value specifications up to 5 digits for low or high range limits within the range of -32 to 32. When reverse range is designated, specify Lower Range Value (LRV) as greater than Upper Range Value (URV). When Square root Output mode in EJX11B is specified, LRV must be (zero). 2) Unit Specify only one unit from Table A. Table A. Available Range Unit EJX11B, EJX3B mmh 2 O, mmh 2 O (6 F), mmhg, Pa, kpa, MPa, mbar, bar, gf/cm 2,kgf/cm 2, inh 2 O, inh 2 O (6 F), inhg, fth 2 O, fth 2 O (6 F) or psi. 3. Output mode For choices, refer to Table B. - For EJX11B, select Linear or Square root. Specify the same mode as that of Display mode. - For EJX3B, select Linear.. Display setting (SCALE) 1) Display scale and unit Specify either to 1 % or Desired Range and Unit for engineering unit scale: - When Desired Range and Unit is specified, scale range can be specified with range limit specifications up to 5 digits for low or high range limits within the range of -32 to 32. Unit display consists of 6-digit, therefore, if the specified scaling unit excluding / is longer than 6-characters, the first 6 characters will be displayed on the unit display. When Square root Output mode in EJX11B is specified, LRV must be (zero). 2) Display mode For choices, refer to Table B. - For EJX11B, select either Linear or Square root. Specify the same mode as that of Display mode. - For EJX3B, select Linear. Table B. Output mode and display mode Output mode LINEAR SQUARE ROOT Display mode LINEAR : EJX11B SQUARE ROOT : EJX3B : Applicable, : Not applicable 5. Tag Number (if required) Specify Tag number (up to 16 letters) to be engraved on the tag plate. The specified letters are written on TAG_Name (16 letters) in the amplifier memory. 6. Software tag (if required) Specify this software tag when tag number which is different from the tag number specified in the TAG NUMBER is required. The tag number specified in SOFTWARE TAG will be entered on TAG (up to 16 letters) in the amplifier memory. 7. Network ID (if required) Specify the number from 2 to When not specified, it will use 1 as the default.. Other Items related with options 1) When option code /R is selected; [COMPENSATION TEMPERATURE] Specify the process operating temperature for the compensation of zero shift by fill fluid density change. The specified value must be within the range from degc to a maximum temperature applicable for the fill fluid. When combined with option code TF1, the value is limited to 15 degc. Note that the unit for this value is degc. Specifying of unit is unnecessary. < Factory Setting > Tag No. Blank unless otherwise specified in order Software tag Blank unless otherwise specified in order Network ID 1 unless otherwise specified in order. Static display range (For EJX11B only) to 25 MPa for M and H capsule, absolute value. Measuring low side. < Reference > 1. is aregistered trademark of Yokogawa Electric Corporation. 2. Teflon; Trademark of E.I. DuPont de Nemours & Co. 3. Hastelloy; Trademark of Haynes International Inc. Other company names and product names used in this material are registered trademarks or trademarks of their respective owners. All Rights Reserved. Copyright 29, Yokogawa Electric Corporation Subject to change without notice. GS 1C27H1-1EN July 19, 216-

General Specifications

General Specifications General Specifications EJX510B and EJX530B Absolute and Gauge Pressure Transmitters The high performance absolute and gauge pressure transmitters EJX510B and EJX530B feature single crystal silicon resonant

More information

General Specifications

General Specifications General Specifications EJX510B and EJX530B Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitters EJX510B and EJX530B feature single crystal silicon resonant

More information

General Specifications

General Specifications General Specifications GS 1C25J3-1E EJX3A Diaphragm Sealed Gauge Pressure Transmitter Diaphragm seal is used to prevent process medium form entering directly into the pressure-sensing assembly of the pressure

More information

General Specifications

General Specifications General Specifications GS 01C25J03-01EN EJX438A Diaphragm Sealed Gauge Pressure Transmitter [Style: S2] Diaphragm seal is used to prevent process medium form entering directly into the -sensing assembly

More information

General Specifications

General Specifications General Specifications EJX118A Diaphragm Sealed Differential Pressure Transmitter [Style: S2] Diaphragm seals are used to prevent process medium form entering directly into the -sensing assembly of the

More information

General Specifications

General Specifications General Specifications GS 01C25J03-01EN EJX438A Diaphragm Sealed Gauge Pressure Transmitter [Style: S2] Diaphragm seal is used to prevent process medium form entering directly into the -sensing assembly

More information

General Specifications

General Specifications General Specifications GS 1C22H1-EN EJA11W, EJA11N and EJA11Y Diaphragm Sealed Differential Pressure Transmitters [Style: S2] Diaphragm seals are used to prevent process medium form entering directly into

More information

General Specifications

General Specifications General Specifications Model EJA3W and EJA3N Diaphragm Sealed Gauge Pressure Transmitters GS 1C22J3-E [Style: S2] Diaphragm seal is used to prevent process medium from entering directly into the pressure-sensing

More information

General Specifications

General Specifications General Specifications GS 01C25F01-01E EJX510A and EJX530A Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitter EJX510A and EJX530A feature single crystal

More information

General Specifications

General Specifications General Specifications YFGW510 Field Wireless Access Point GS 01W02E01-01EN GENERAL This General Specification(GS) describes the hardware specifications for Field Wireless Management Station and specifications

More information

General Specifications

General Specifications General Specifications YFGW520 Field Wireless Access Point GS 01W02E02-01EN GENERAL This General Specification(GS) describes the hardware specifications for Field Wireless Access Point and specifications

More information

General Specifications

General Specifications General Specifications Model EJA120A Differential Pressure Transmitter GS 01C21B03-00E The high performance draft range differential transmitter model EJA120A outputs a 4 to 20 ma DC signal corresponding

More information

General Specifications

General Specifications General Specifications YFGW510 Field Wireless Access Point GS 01W02E01-01EN GENERAL This General Specification(GS) describes the hardware specifications for Field Wireless Access Point and specifications

More information

General Specifications

General Specifications General Specifications EJX110A Differential Pressure Transmitter GS 01C25B01-01E The high performance differential transmitter EJX110A features single crystal silicon resonant sensor and is suitable to

More information

General Specifications

General Specifications General Specifications YFGW510 Field Wireless Access Point GS 01W02E01-01EN GENERAL This General Specification(GS) describes the hardware specifications for Field Wireless Access Point and specifications

More information

General Specifications

General Specifications General Specifications YFGW510 Field Wireless Access Point GS 01W02E01-01EN GENERAL This General Specification(GS) describes the hardware specifications for Field Wireless Access Point and specifications

More information

General Specifications

General Specifications General Specifications EJA120E Differential Pressure Transmitter The high performance draft range differential pressure transmitter EJA120E features single crystal silicon resonant sensor and is suitable

More information

General Specifications

General Specifications General Specifications EJA110E Differential Pressure Transmitter The high performance differential transmitter EJA110E features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications Model EJA440A Gauge Pressure Transmitter GS 01C21E02-00E The high performance gauge transmitter model EJA440A can be used to measure liquid, gas, or steam. It outputs a 4 to 20 ma

More information

General Specifications

General Specifications General Specifications EJA510E and EJA530E Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitter EJA510E and EJA530E feature single crystal silicon resonant

More information

General Specifications

General Specifications General Specifications EJX120A Differential Pressure Transmitter The high performance draft range differential pressure transmitter EJX120A features single crystal silicon resonant sensor and is suitable

More information

General Specifications

General Specifications General Specifications FN510 Field Wireless Multi-Function Module GENERAL This General Specification (GS) describes the specifications for Field Wireless Multi-Function Module. Combined with Field Wireless

More information

General Specifications

General Specifications General Specifications EJX430A Gauge Pressure Transmitter GS 01C25E01-01E [Style: S2] The high performance gauge transmitter EJX430A features single crystal silicon resonant sensor and is suitable to measure

More information

General Specifications

General Specifications General Specifications EJA530E S-Series Cherry Burrell I Line Sanitary Pressure Transmitter GS 530SCBS-01E The EJA530E S-Series sanitary pressure transmitters combine Yokogawa s EJA-E series in-line pressure

More information

General Specifications

General Specifications General Specifications GS 01C25F01-01E EJX510A and EJX530A Absolute and Gauge Pressure Transmitter [Style: S2] The high performance absolute and gauge pressure transmitter EJX510A and EJX530A feature single

More information

Wireless Pressure Transmitter Differential Pressure Models Series XYR 6000 Specifications

Wireless Pressure Transmitter Differential Pressure Models Series XYR 6000 Specifications Wireless Pressure Transmitter Differential Pressure Models Series XYR 6000 Specifications 34-XY-03-22 November 2010 Introduction Building upon the tremendously successful ST 3000 series transmitter line;

More information

General Specifications

General Specifications General Specifications EJX430A Gauge Pressure Transmitter [Style: S2] The high performance gauge transmitter EJX430A features single crystal silicon resonant sensor and is suitable to measure liquid, gas,

More information

General Specifications

General Specifications General Specifications FN310 Field Wireless Multi-Protocol Module GENERAL This General Specification (GS) describes the specifications for Field Wireless Multi-Protocol Module. Combined with Field Wireless

More information

General Specifications

General Specifications General Specifications EJA310E Absolute Pressure Transmitter The high performance absolute transmitter EJA310E features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or

More information

General Specifications

General Specifications General Specifications EJA130E Differential Pressure Transmitter The high performance differential transmitter EJA130E features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications EJX110A Differential Pressure Transmitter [Style: S3] The high performance differential transmitter EJX110A features single crystal silicon resonant sensor and is suitable to measure

More information

General Specifications

General Specifications General Specifications EJA130E Differential Pressure Transmitter [Style: S2] The high performance differential transmitter EJA130E features single crystal silicon resonant sensor and is suitable to measure

More information

General Specifications

General Specifications General Specifications YTMX580 Multi-Input Temperature Transmitter GS 04R01B01-01EN The model YTMX580 Multi-Input Temperature Transmitter can accept inputs from up to 8 points of measurement such as thermocouples

More information

General Specifications

General Specifications General Specifications EJX310A Absolute Pressure Transmitter [Style: S2] The high performance absolute transmitter EJX310A features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications EJA110E Differential Pressure Transmitter The high performance differential transmitter EJA110E features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications EJA440E Gauge Pressure Transmitter The high performance gauge transmitter EJA440E features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam.

More information

General Specifications

General Specifications General Specifications EJX510A and EJX530A Absolute and Gauge Pressure Transmitter [Style: S2] The high performance absolute and gauge pressure transmitter EJX510A and EJX530A feature single crystal silicon

More information

General Specifications

General Specifications General Specifications EJX Series FOUNDATION TM Fieldbus Communication FOUNDATION fieldbus is the digital communication line for the field instruments, whose signal is internationally standardized by Fieldbus

More information

General Specifications

General Specifications General Specifications EJA120E Differential Pressure Transmitter The high performance draft range differential pressure transmitter EJA120E features single crystal silicon resonant sensor and is suitable

More information

General Specifications

General Specifications General Specifications EJX430A Gauge Pressure Transmitter [Style: S2] The high performance gauge transmitter EJX430A features single crystal silicon resonant sensor and is suitable to measure liquid, gas,

More information

General Specifications

General Specifications General Specifications EJX130A Differential Pressure Transmitter [Style: S2] The high performance differential transmitter EJX130A features single crystal silicon resonant sensor and is suitable to measure

More information

General Specifications

General Specifications General Specifications EJA440E Gauge Pressure Transmitter The high performance gauge transmitter EJA440E features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam.

More information

General Specifications

General Specifications General Specifications EJX115A Low Flow Transmitter [Style: S1] The low flow transmitter EJX115A is a differential transmitter assembled with an integral orifice and excellent for very low flow measurement.

More information

General Specifications

General Specifications General Specifications YTA70 Temperature Transmitter The YTA70 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC

More information

General Specifications

General Specifications General Specifications EJX120A Differential Pressure Transmitter The high performance draft range differential pressure transmitter EJX120A features single crystal silicon resonant sensor and is suitable

More information

General Specifications

General Specifications General Specifications EJX310A Absolute Pressure Transmitter [Style: S2] The high performance absolute transmitter EJX310A features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications EJA310E Absolute Pressure Transmitter [Style: S2] The high performance absolute transmitter EJA310E features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications EJA510E and EJA530E Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitter EJA510E and EJA530E feature single crystal silicon resonant

More information

General Specifications

General Specifications General Specifications EJA510E and EJA530E Absolute and Gauge Pressure Transmitter [Style: S2] The high performance absolute and gauge pressure transmitter EJA510E and EJA530E feature single crystal silicon

More information

Field Wireless Access Point

Field Wireless Access Point Field Wireless Access Point R-Y510 Features Connects Cosasco Wireless devices and other ISA100 Wireless transmitters to a Field Wireless Management Station High-performance, compact industrial wireless

More information

General Specifications

General Specifications General Specifications EJA110E Differential Pressure Transmitter The high performance differential transmitter EJA110E features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

Wireless Transmitter Gauge Pressure Models Series XYR 6000 Specifications

Wireless Transmitter Gauge Pressure Models Series XYR 6000 Specifications Wireless Transmitter Gauge Pressure Models Series XYR 6000 Specifications 34-XY-03-24 November 2010 Introduction Building upon the tremendously successful ST 3000 series transmitter line; Honeywell brings

More information

General Specifications

General Specifications General Specifications EJX440A Gauge Pressure Transmitter [Style: S2] The high performance gauge transmitter EJX440A features single crystal silicon resonant sensor and is suitable to measure liquid, gas,

More information

General Specifications

General Specifications General Specifications EJX310A Absolute Pressure Transmitter [Style: S2] The high performance absolute transmitter EJX310A features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications EJA110E Differential Pressure Transmitter [Style: S2] The high performance differential transmitter EJA110E features single crystal silicon resonant sensor and is suitable to measure

More information

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS Rosemount 2051 Product Data Sheet PERFORMANCE SPECIFICATIONS Specifications For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange () or 1 /2 in. - 14 NPT () process

More information

General Specifications

General Specifications General Specifications EJA440E Gauge Pressure Transmitter [Style: S2] The high performance gauge transmitter EJA440E features single crystal silicon resonant sensor and is suitable to measure liquid, gas,

More information

General Specifications

General Specifications General Specifications EJX110A Differential Pressure Transmitter [Style: S3] The high performance differential transmitter EJX110A features single crystal silicon resonant sensor and is suitable to measure

More information

General Specifications

General Specifications General Specifications EJX430A Gauge Pressure Transmitter [Style: S2] The high performance gauge transmitter EJX430A features single crystal silicon resonant sensor and is suitable to measure liquid, gas,

More information

DRS390 High stability, flange mounting

DRS390 High stability, flange mounting DRS 390 1 Monocrystalline silicon smart differential pressure transmitter DRS390 High stability, flange mounting Detailed Information Application the flow of gas, vapor and liquid measurement with device

More information

General Specifications

General Specifications General Specifications EJA110A Differential Pressure Transmitter The high performance differential transmitter model EJA110A can be used to measure liquid, gas, or steam flow as well as liquid level, density

More information

11A Series Absolute Pressure Transmitters

11A Series Absolute Pressure Transmitters Product Specifications 11A Series Absolute Pressure Transmitters PSS 2B-1A1 A 11 SERIES TRANSMITTER 11 SERIES TRANSMITTER 11 SERIES TRANSMITTER In 11A Series Transmitters, the reliable force-balance d/p

More information

FIELD DEVICES PRESSURE

FIELD DEVICES PRESSURE FIELD DEVICES PRESSURE Product Specifications Models 11GM and 11GH Pneumatic Transmitters for Gauge Pressure Measurement 11GM TRANSMITTER 11GH TRANSMITTER The Foxboro brand Models 11GM and 11GH Transmitters

More information

Wireless Multi Discrete Input Transmitter Series XYR 6000, Model STXW500 Specifications

Wireless Multi Discrete Input Transmitter Series XYR 6000, Model STXW500 Specifications Wireless Multi Discrete Input Transmitter Series XYR 6000, Model STXW500 Specifications 34-XY-03-33 February 2010 Model STXW500 - Up to 3 discrete inputs) Introduction Building upon the tremendously successful

More information

General Specifications

General Specifications General Specifications Model EJ430 Gauge Pressure Transmitter GS 01C21E01-00E The high performance gauge transmitter model EJ430 can be used to measure liquid, gas, or steam. It outputs a 4 to 20 m DC

More information

General Specifications

General Specifications General Specifications odel EJA110A Differential Pressure Transmitter GS 01C21B01-00E The high performance differential transmitter model EJA110A can be used to measure liquid, gas, or steam flow as well

More information

Accutech DP20. Wireless differential pressure field unit

Accutech DP20. Wireless differential pressure field unit Accutech DP20 Wireless differential pressure field unit 1 The Accutech DP20 differential pressure field unit provides differential pressure data in a variety of ranges up to +/-300in H 2 0. Both traditional

More information

General Specifications

General Specifications General Specifications odel EJA130A Differential Pressure Transmitter GS 01C21B04-00E The high performance differential transmitter model EJA130A can be used to measure liquid, gas, or steam flow as well

More information

General Specifications

General Specifications General Specifications Model EJ430 Gauge Pressure Transmitter GS 01C21E01-00E The high performance gauge transmitter model EJ430 can be used to measure liquid, gas, or steam. It outputs a 4 to 20 m DC

More information

PTG series Smart Pressure Transmitter

PTG series Smart Pressure Transmitter No. SS2-PTG300-0100 PTG series Smart Pressure Transmitter Model PTG71 / PTG72 OVERVIEW The Smart Pressure Transmitter model PTG is a high- performance, highly reliable gauge pressure transmitter. Based

More information

General Specifications

General Specifications General Specifications YTMX580 Multi-Input Temperature Transmitter GS 04R01B01-01EN The model YTMX580 Multi-Input Temperature Transmitter can accept inputs from up to 8 points of measurement such as thermocouples

More information

General Specifications

General Specifications General Specifications odel EJ120 Differential Pressure Transmitter The high performance draft range differential transmitter model EJ120 outputs a 4 to 20 m DC signal corresponding to the measured differential.

More information

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS DRS 300 1 Monocrystalline silicon smart differential pressure transmitter DRS300 High stability Detailed Information application the flow of gas, vapor and liquid measurement with device (volume or mass

More information

AT9000 Advanced Transmitter Differential Pressure Transmitters

AT9000 Advanced Transmitter Differential Pressure Transmitters AT9000 Advanced Transmitter Differential Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability. Capable

More information

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL WITH DIAPHRAGM SEAL APT3200L Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate Fuel Autrol America

More information

General Specifications

General Specifications General Specifications EJ510 and EJ530 bsolute and Gauge Pressure Transmitters [Style: S2] The absolute and gauge pressure transmitter model EJ510 and EJ530 can be used to measure liquid, gas, or steam

More information

Differential Pressure Transmitters

Differential Pressure Transmitters AT9000 Advanced Transmitter Differential Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and ecellent stability. Capable

More information

PAD - Heavy Duty Differential Pressure Trasmitter

PAD - Heavy Duty Differential Pressure Trasmitter Benefits and Features Span: 0.3" W.C. 6" W.C. to 60 6000 PSIG Static Pressure: Max. 4500 PSIG t max : 248 F Process Connection: ½" NPT, ¼" NPT, or Various Diaphragm Seals Available upon Request Material:

More information

General Specifications

General Specifications General Specifications YTA110 Temperature Transmitter [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs and converts it to

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability.

More information

Wireless Transmitter Series XYR 6000 Absolute Pressure Model STAW94L 0 to 500 psia 0 to 35 bara Specifications

Wireless Transmitter Series XYR 6000 Absolute Pressure Model STAW94L 0 to 500 psia 0 to 35 bara Specifications Wireless Transmitter Series XYR 6000 Absolute Pressure Model STAW94L 0 to 500 psia 0 to 35 bara Specifications 34-XY-03-23 March 2012 Introduction Building upon the tremendously successful ST 3000 series

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters

AT9000 Advanced Transmitter Gauge Pressure Transmitters AT9000 Advanced Transmitter Gauge Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability. Capable

More information

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 DOC. NO. : C3200-E04A FM APPROVED Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 APT3200 Smart Pressure Transmitter Standard SST Housing Description of Product The

More information

General Specifications

General Specifications General Specifications odel EJ310 bsolute Pressure Transmitter GS 01C21D01-00E The high performance gauge transmitter model EJ310 can be used to measure liquid, gas, or steam. It outputs a 4 to 20 m DC

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters

AT9000 Advanced Transmitter Gauge Pressure Transmitters AT9000 Advanced Transmitter Gauge Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability. Capable

More information

Absolute Pressure Transmitters

Absolute Pressure Transmitters AT9000 Advanced Transmitter Absolute Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and ecellent stability. Capable

More information

FIELD DEVICES - PRESSURE

FIELD DEVICES - PRESSURE FIELD DEVICES - PRESSURE Product Specifications Logo Models 15A, 13A, and 13HA Pneumatic d/p Cell Transmitters PSS 2B-1C1 A The Foxboro brand Models 15A, 13A, and 13HA pneumatic d/p Cell transmitters measure

More information

FUNCTIONAL SPECIFICATIONS

FUNCTIONAL SPECIFICATIONS DATA SHEET The ProcessX differential pressure (flow) transmitter accurately measures differential pressure, liquid leel, gauge pressure or fl ow rate and transmits a proportional 4 to 20mA signal. The

More information

General Specifications

General Specifications General Specifications YTA60 Temperature Transmitter The YTA60 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC

More information

General Specifications

General Specifications General Specifications GS 01F06F01-01EN Model DY Vortex Flowmeter Model DYA Vortex Flow Converter FOUNDATION Fieldbus Communication Type General FOUNDATION Fieldbus is the digital communication line for

More information

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A Doc. No. : C3100-E05A Smart Pressure Transmitter for Differential / Gauge / Absolute Pressure Measurement MODEL APT3100 Duon System Co.,Ltd. www.autrol.com Smart Pressure Transmitter APT3100 Standard Description

More information

General Specifications

General Specifications General Specifications EJX910A Multivariable Transmitter [Style: S2] The high performance EJX910A multivariable transmitter features multi-sensing technology with a single-crystal silicon resonant sensor

More information

Field IT 2600T Series Pressure Transmitters

Field IT 2600T Series Pressure Transmitters Data Sheet Field IT 2600T Series Pressure Transmitters Model 364GS Gauge Model 364AS Absolute standard overload Best in class total performance long term stability of 0.25% for 10 years base accuracy of

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability.

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters

AT9000 Advanced Transmitter Gauge Pressure Transmitters AT9000 Advanced Transmitter Gauge Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and ecellent stability. Capable of

More information

XYR 6000 Wireless Temperature/Discrete Input Transmitter Series 400 Specifications

XYR 6000 Wireless Temperature/Discrete Input Transmitter Series 400 Specifications XYR 6000 Wireless Temperature/Discrete Input Transmitter Series 400 Specifications 34-XY-03-29 December 2010 Introduction Building upon the tremendously successful ST 3000 series transmitter line; Honeywell

More information

ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE)

ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE) ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE) DATA SHEET FKH...5 The FCX AIII absolute pressure transmitter (Direct mount type) accurately measures absolute pressure and transmits proportional 4 to

More information

Absolute Pressure Transmitters

Absolute Pressure Transmitters No. SS2-GTX00A-0100 AT9000 Advanced Transmitter Absolute Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information

General Specifications

General Specifications General Specifications GS 01C21F01-00E odel EJ510 and EJ530 bsolute and Gauge Pressure Transmitter [Style: S2] The absolute and gauge pressure transmitter model EJ510 and EJ530 can be used to measure liquid,

More information