Modelling III ABSTRACT
|
|
- Cuthbert Marshall
- 5 years ago
- Views:
Transcription
1 Modelling III Hybrid FE-VIM Model of Eddy Current Inspection of Steam Generator Tubes in the Vicinity of Tube Support Plates S. Paillard, A. Skarlatos, G. Pichenot, CEA LIST, France G. Cattiaux, T. Sollier, IRSN, France ABSTRACT Modelling of eddy current inspection of Steam Generator (SG) tubes near tube support plate () is beneficial for the validation of existing industrial Non Destructive Testing (NDT). Eddy current inspection of Steam Generator tubes in the vicinity of tube support plates is an important aspect of the safety of the nuclear plants. The appearance of material defects like corrosion or cracking is frequent for alloy 600 MA in this particular region of the SG installations. The detection of defects in the proximity of support plate presents increased difficulties due to the perturbation signals arising from the presence of the plate. Additional effects like gradual deposit of conducting or/and ferromagnetic material in the gap between the plate hole and the tube external wall may create additional perturbations which have to be identified and distinguished from the flaw signature as well. The aim of this collaborative work between CEA and IRSN is to extend the capabilities of the CIVA software by developing a simulation tool for the evaluation of industrial non-destructive testing method used for the tube inspection in the support plate region. For the numerical modelling of this problem, a combination of the Finite Elements Method (FEM) with the Volume Integral Method (VIM) is used in order to combine the advantages of the two techniques. According to this approach, the primary field is calculated using the FEM for the tubeplate ensemble whereas the flaw response is calculated via the VIM. First, we will introduce the principle of the hybrid method, we will describe the Finite Element model (FLUX) and the Volume Integral Method (CIVA) used in this hybrid model. Then, we will summarize the most important validation results of our previous communication (inspection of Steam Generator tubes in the vicinity of quatrefoil-shaped holes tube support plates with a bobbin coil). These results show that the proposed hybrid method is able to handle such configurations. Finally, we will present a simulation taking into account quatrefoil-shaped holes support plates and magnetic material deposit support plates with a bobbin coil. All these results are validated by experimental data. Application cases concerning support plates with magnetic quatrefoil-shaped holes with or without magnetic material deposit are given in this article to illustrate the good agreement between simulation and experimental data. INTRODUCTION The aim of this collaborative work between CEA and IRSN is to extend the capabilities of the CIVA software by developing a simulation tool for the evaluation of industrial non-destructive testing method used for the tube inspection in the support plate region. For the numerical modeling of this problem, a combination of the Finite Elements Method with the Volume Integral Method is used in order to combine the advantages of the two techniques. According to this approach, the primary field is calculated using the FEM for the tube-plate ensemble whereas the flaw response is calculated via the VIM. In a previous communication [7], we presented application and simulation cases concerning support plates with circular and quatrefoil-shaped holes. The results show that the proposed method is enabling to handle such configurations. Since, we worked on taking into account quatrefoil-shaped holes support plates and magnetic material deposit in the same configuration. Application cases concerning support plates with magnetic quatrefoil-shaped holes with or without magnetic material in the same configuration will be given in this article to illustrate the good agreement between simulation and experimental data.
2 HYBRID FE-VIM MODEL inc The coupling approach adopted in this work is described in [3]. The primary field E 2, i.e. the electric field induced inside the tube wall in the absence of the flaw, is calculated using the FEM. Since the defect is usually of small volume in respect to the rest of the structure, one can consider that the perturbation to the eddy current flow is of local character and thus neglect its interaction with the. Hence, the flaw response can be calculated with good accuracy by solving the volume integral equation approach applied for the free span area [1, 2] E2 = 2 0, δσ ee ( r ) E ( r ) + jωµ G22 ( r r ) ( r ) E ( r ) dv inc 2 ee V f where the Green dyad G22 corresponds to the dyad of a cylindrical multilayered medium. In the above equation, the tube is described in terms of a cylindrical multilayered structure the second layered being assigned to the tube wall, the first and the third ones being referred to the interior and the exterior of the tube respectively. Once the total field E 2 has been evaluated, the mutual impedance between the driving coil and each of the receiving coils of the probe can be calculated using the reciprocity theorem [5]: Z ji 1 = I I j i V f (1) inc δσ ( r ) E ( r ) E ( ) d 2, j 2, i r V. (2) inc where E 2, j denotes the primary field that would be induced by the considered receiving coil j if it was excited with a current I j, and I i is the excitation current of the driving coil. E 2, i is the total field in the flaw region and is obtained by the solution of Eq. (1). The unperturbed values of the impedance matrix at the different scanning positions Z ji depend on the tube- configuration and are obtained by the post-processing of the FEM solution. The final probe response is then calculated using the above values of Z ji and Z ji taking into account the operational mode of the probe (function in absolute or differential mode). As in the case of the with circular and quatrefoil-holes, an optimization algorithm has been developed in order to estimate the most pertinent positions of the probe and hence to minimize the number of FEM simulations. APPLICATIONS PARAMETERS The presented model as been applied for the simula tion of eddy current inspection of a SG tube in
3 The EC signals are computed at three frequencies: 100 khz, 240 khz and 500 khz but illustrated in this article only for the most significant frequency for the signal, 100 khz. Both simulation and experimental results are calibrated in respect to the signals of a reference flaw. The reference flaw consists of a set of 4 through-holes of 1 mm diameter, circumferentially distributed every identical coils operating at differential mode Inner radius: 7.83 mm Outer radius: 8.5 mm Height: 2 mm Coils distance: 0.5mm Number of turns: 70 Figure 2 - Problem configuration: bobbin coil in a SG tube with a quatrefoil FEM calculation parameters The quatrefoil tube support plate () properties of the experimental mock-up (depicted in Figure 3) are representative of those met in a typical pressurized water reactor. The conductivity of the was measured at 1.4 MS/m and the relative permeability estimated at 30. Side Face Cross-Section Figure 3 - Problem configuration: SG tube with a quatrefoil The FEM calculations are carried our using the Flux-3D package. An important feature of the hybrid approach is that the primary field has to be calculated only once for a given tube, and probe configuration which makes the approach significantly faster than treating the entire problem (primary field and flaw interaction) using the FEM only. The FEM calculation needs to be done cautiously because of the high sensibility of the result to the mesh chosen. On the Figure 4 an FEM mesh is illustrated for the treatment of the tube-bobbin coil configuration described above. In order to reduce the time of FEM calculation, only a quadrant is really treated.
4 Figure 4 - Problem configuration: bobbin coil (blue) in a SG tube (yellow) with a quatrefoil (green). FEM mesh used for the calculation of the primary field and the self and mutual impedances of the two coils Semi-analytical calculation parameters Once the surrounding environment (influence on the probe of the ) calculated with FEM, the semi-analytical model takes this result in account in the calculation of flaw effect. The defects considered for the validation are representative of the typical tube degradations in the area of the, which are principally the Intergranular Stress Corrosion Cracking (IGSCC). More over another type of configuration is also considered: a magnetic deposit. The geometry and the dimensions of the considered flaws and deposit illustrated in this article are given in Table 1. Table 1 - Examined flaws for the validation of the developed combined formulation. The flaw radial dimensions are given as percentages of the tube thicknesse Flaws and deposit Dimensions / e Angular Extension Longitudinal Extension External Groove EG40 40 % 360º 1 mm External Longitudinal Notch ELN10 54 % 0.6º 10 mm Magnetic deposit 300 µm mm APPLICATION TO A QUATREFOIL TUBE SUPPORT PLATE In a previous communication, we presented application and simulations cases concerning support plates with circular and quatrefoil-shaped holes. In order to introduce the latest results (magnetic deposit), we will summarize in this paragraph, the two most important validation results which are applications to SG tube with grooves and notches in the vicinity of tube support plate (). The model has been applied for the simulation of eddy current inspection of a SG tube with an external groove (EG40) and with an external notch (ELN10) in the vicinity of a quatrefoil. These results have been validated using experimental measurements.
5 Validation on an external groove For this application (Figure 5), we consider a centred on an external groove (EG40). The calculation of the is carried out by the FEM model and this result is taking into account in the semi-analytical calculation of the probe response to the groove. Figure 5 - Problem configuration: external groove in a SG tube with a quatrefoil External groove Experiment Experiment (without SP) Simulation External groove Figure 6 - Simulated vs. measured signals for EG40 at 100 khz: (blue) experimental signal with, (black) simulated signal with and (red) experimental signal without. The above plots give the signals on the complex plane (left side) and their real and imaginary parts as function of the probe scanning position. The above plots (Figure 6) give the signals on the complex plane (left side) and their real and imaginary parts as function of the probe scanning position. The simulated signal (Figure 6, black) is in good agreement with the experimental signal with (blue). For a better understanding of the effect, the experimental signal without (red) is also presented. Both and EG40 signatures appear clearly in the probe response because of the distance between the edges and the groove.
6 Validation on an external longitudinal notch This validation (Figure 7) considers an external longitudinal notch (ELN10) with a height of 10 mm (the height of the groove is 1 mm) centred on the quatrefoil (with a thickness of 30 mm). On Figure 8, we can notice that the both signatures appear closely and are well-combined by the hybrid model and these results are in good agreement with experimental data in the case of an ELN10 in a SG tube with a quatrefoil. Figure 7 - Problem configuration: longitudinal notch in a SG tube with a quatrefoil External longitudinal notch Experiment Experiment (without SP) Simulation longitudinal notch Figure 8 - Simulated vs. measured signals for ELN10 at 100 khz: (blue) experimental signal with, (black) simulated signal with and (red) experimental signal without. The above plots give the signals on the complex plane (left side) and their real and imaginary parts as function of the probe scanning position.
7 APPLICATION TO A QUATREFOIL TUBE SUPPORT PLATE WITH DEPOSIT The presented model has been validated on flaws such as grooves and notches. Now, the model has to be validated on more complex configurations: magnetic deposit. The model has been applied for the simulation of eddy current inspection of a SG tube in the vicinity of a quatrefoil. The results of the hybrid approach have been validated using experimental measurements. Validation with the centred on the deposit For this application, we consider a centred on a magnetic deposit (Figure 9). The calculation of the is carried out by the FEM model and this result is taking into account in the semi-analytical calculation of the probe response to the deposit with. Figure 9 - Problem configuration: SG tube with a quatrefoil centred on the deposit Deposit Experiment Experiment (without SP) Simulation Deposit Deposit Figure 10 - Simulated vs. measured signals for deposit centred on the at 100 khz: (blue) experimental signal with, (black) simulated signal with and (red) experimental signal without. The above plots give the signals on the complex plane (left side) and their real and imaginary parts as function of the probe scanning position.
8 These results are in good agreement with experimental data in the case of a deposit on a SG tube with a quatrefoil centred on the deposit presented above in Figure 10. Both and deposit signatures appear in the probe response (Figure 10) because of the distance between the edges and the deposit. Two magnetic elements are taking into account in this validation: the deposit, which is handling by the semi-analytical model and the, which is handling by the FEM model. The two signatures are well-combined by the hybrid model. Validation with the centred on an edge of the deposit For this application, we consider a centred on an edge of the magnetic deposit (Figure 10). The calculation of the is carried out by the FEM model and this result is taking into account in the semi-analytical calculation of the probe response to the deposit with. Figure 11 - Problem configuration: SG tube with a quatrefoil centred on an edge of a deposit Deposit Experiment Experiment (without SP) Simulation + Deposit Deposit Figure 12 - Simulated vs. measured signals for deposit centred on an edge of the at 100 khz: (blue) experimental signal with, (black) simulated signal with and (red) experimental signal without. The above plots give the signals on the complex plane (left side) and their real and imaginary parts as function of the probe scanning position.
9 These results are in good agreement with experimental data in the case of deposit on a SG tube with a quatrefoil centred on an edge of the deposit presented above in Figures 11 and 12. Even more than in the last validation ( centred on the deposit), this application show that the hybrid method is not a simple addition of signatures but a well-combination of surrounding effect on the probe and degradation interaction. CONCLUSION The hybrid FEM-VIM approach used for the simulation of eddy-current inspection of tubes near support plates with cylindrical openings presented
Eddy Current Modelling for Fasteners Inspection in Aeronautic
ECNDT 2006 - Tu.4.4.5 Eddy Current Modelling for Fasteners Inspection in Aeronautic Séverine PAILLARD, Grégoire PICHENOT, CEA Saclay, Gif-sur-Yvette, France Marc LAMBERT, L2S (CNRS-Supélec-UPS), Gif-sur-Yvette
More informationEDDY CURRENT INSPECTION MODELLING OF THE ELBOW OF A STEAM GENERATOR TUBE WITH THE FINITE ELEMENT SOFTWARE «FLUX»
EDDY CURRENT INSPECTION MODELLING OF THE ELBOW OF A STEAM GENERATOR TUBE WITH THE FINITE ELEMENT SOFTWARE «FLUX» Fabrice FOUCHER*, Bastien LAVIE**, Erwan TOUDIC** * EXTENDE, 86 rue de Paris, 91400 ORSAY,
More informationEDDY-CURRENT MODELING OF FERRITE-CORED PROBES
EDDY-CURRENT MODELING OF FERRITE-CORED PROBES F. Buvat, G. Pichenot, D. Prémel 1 D. Lesselier, M. Lambert 2 H. Voillaume, J-P. Choffy 3 1 SYSSC/LCME, CEA Saclay, Bât 611, 91191 Gif-sur-Yvette, France 2
More informationIMPROVEMENT OF DETECTION OF SMALL DEFECTS LOCATED NEAR OR FAR FROM WELDS OF MAGNETIC STEAM GENERATOR TUBES USING REMOTE FIELD EDDY CURRENT
12 th A-PCNDT 2006 Asia-Pacific Conference on NDT, 5 th 10 th Nov 2006, Auckland, New Zealand IMPROVEMENT OF DETECTION OF SMALL DEFECTS LOCATED NEAR OR FAR FROM WELDS OF MAGNETIC STEAM GENERATOR TUBES
More informationMaximizing the Fatigue Crack Response in Surface Eddy Current Inspections of Aircraft Structures
Maximizing the Fatigue Crack Response in Surface Eddy Current Inspections of Aircraft Structures Catalin Mandache *1, Theodoros Theodoulidis 2 1 Structures, Materials and Manufacturing Laboratory, National
More informationADVANCED COMBINATION PROBE FOR TESTING FERRITIC SEA-CURE CONDENSER TUBING
ADVANCED COMBINATION PROBE FOR TESTING FERRITIC SEA-CURE CONDENSER TUBING Kenji Krzywosz, Electric Power Research Institute (EPRI), Daniel Folsom, Tennessee Valley Authority (TVA), USA ABSTRACT As more
More informationEDDY CURRENT EXAM SIMULATION USING COUPLED FINITE ELEMENT/ VOLUME INTEGRAL OR FINITE ELEMENT/BOUNDARY ELEMENT METHOD
DDY CURRNT XAM SIMULATION USING COUPLD FINIT LMNT/ VOLUM INTGRAL OR FINIT LMNT/BOUNDARY LMNT MTHOD INTRODUCTION dith A. Creek and Robert. Beissner Southwest Research Institute San Antonio, TX 788 The ability
More information2.5D Finite Element Simulation Eddy Current Heat Exchanger Tube Inspection using FEMM
Vol.20 No.7 (July 2015) - The e-journal of Nondestructive Testing - ISSN 1435-4934 www.ndt.net/?id=18011 2.5D Finite Element Simulation Eddy Current Heat Exchanger Tube Inspection using FEMM Ashley L.
More informationR&D of Multi-Frequency ECT Algorithms for FBR SG Tubes
E-Journal of Advanced Maintenance Vol.9- (7) - Japan Society of Maintenology R&D of Multi-Frequency ECT Algorithms for FBR SG Tubes Ovidiu MIHALACHE, Toshihiko YAMAGUCHI, Takuma SHIRAHAMA and Masashi UEDA
More informationDepth of Penetration Effects in Eddy Current Testing
Depth of Penetration Effects in Eddy Current Testing Shiva Majidnia 1, John Rudlin 2 and Ragogapol Nilavalan 3 Brunel University Cambridge CB1 6AL, UK Telephone 01223 899000 Fax 01223 890689 E-mail shiva.majidnia@twi.co.uk
More informationEffect of fatigue crack orientation on the sensitivity of eddy current inspection in martensitic stainless steels
Effect of fatigue crack orientation on the sensitivity of eddy current inspection in martensitic stainless steels Hamid Habibzadeh Boukani, Ehsan Mohseni, Martin Viens Département de Génie Mécanique, École
More informationSteam Generator Tubing Inspection
6th International Conference on NDE in Relation to Structural Integrity for Nuclear and Pressurized Components October 27, Budapest, Hungary For more papers of this publication click: www.ndt.net/search/docs.php3?mainsource=7
More informationDevelopments in Electromagnetic Inspection Methods I
6th International Conference on NDE in Relation to Structural Integrity for Nuclear and Pressurized Components October 2007, Budapest, Hungary For more papers of this publication click: www.ndt.net/search/docs.php3?mainsource=70
More informationSimulation Model for SG Eddy Current SG Inspection
Simulation Model for SG Eddy Current SG Inspection Saptarshi Mukherji, Anton Efremov, Pavel Roy, Portia Banerjee, Anders Rosell, L.Udpa Michigan State University & Rick Williams, Nathan Driessen, James
More informationSteam Generator Tube Inspection I
Steam Generator Tube Inspection I 3D emote Field-Eddy Current Simulation of the Support Plates of the Magnetic Steam Generator Tubes in FB O. Mihalache, T. Yamaguchi, M. Ueda, S. Miyahara, Japan Atomic
More informationDEVELOPMENT OF EDDY CURRENT PROBES BASED ON MAGNETORESISTIVE ARRAY SENSORS
DEVELOPMENT OF EDDY CURRENT PROBES BASED ON MAGNETORESISTIVE ARRAY SENSORS N. Sergeeva-Chollet, C.Fermon, J.-M. Decitre, M. Pelkner, V.Reimund, M. Kreutzbruck QNDE, July, 25, 2013 CEA 10 AVRIL 2012 OUTLINE
More informationMultiple Frequency Eddy Current Technique
Multiple Frequency Eddy Current Technique Signal Amplitude Signal Amplitude Multiple Frequency Eddy Current Technique Multiple Frequency Eddy Current technique is one of the non destruction inspection
More informationFlexible PCB-Based Eddy Current Array Probes for the Inspection of Turbine Components
Flexible PCB-Based Eddy Current Array Probes for the Inspection of Turbine Components Andre Lamarre - OlympusNDT-Quebec City Canada Benoit Lepage - OlympusNDT-Quebec City-Canada Tommy Bourgelas - OlympusNDT-Quebec
More informationHybrid of Eddy Current Probe Based on Permanent Magnet and GMR Sensor
Hybrid of Eddy Current Probe Based on Permanent Magnet and GMR Sensor Moneer A Faraj 1, Fahmi Samsuri 1, Ahmed N AbdAlla 2 1 Faculty of Electrical and Electronics, University Malaysia Pahang, Malaysia
More informationMultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound
MultiScan MS 5800 Tube Inspection System Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound 920-107 MultiScan MS 5800 E Tube Inspection with Eddy Current Condensers
More informationMultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound
MultiScan MS 5800 Tube Inspection System 920-107 Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound MultiScan MS 5800 E Tube Inspection with Eddy Current Condensers
More informationEddy Current Testing (ET) Technique
Research Group Eddy Current Testing (ET) Technique Professor Pedro Vilaça * * Contacts: Address: Puumiehenkuja 3 (room 202), 02150 Espoo, Finland pedro.vilaca@aalto.fi October 2017 Contents Historical
More informationElectromagnetic Eddy Current Sensors for Evaluation of Sea-Cure and 2205 Duplex Condenser Tubing
6th European Workshop on Structural Health Monitoring - We.3.B.2 More info about this article: http://www.ndt.net/?id=14151 Electromagnetic Eddy Current Sensors for Evaluation of Sea-Cure and 2205 Duplex
More informationSkin Effect in Eddy Current Testing with Bobbin Coil and Encircling Coil
Progress In Electromagnetics Research M, Vol. 65, 137 150, 2018 Skin Effect in Eddy Current Testing with Bobbin and Encircling Jianwei Yang 1, Shaoni Jiao 1,ZhiweiZeng 1, *, Junming Lin 2, and Jincheng
More information2014 EDDY CURRENT BENCHMARK
World Federation of N D 2014 EDDY CURRENT BENCHMARK E Centers The World Federation of NDE Centers pleased to announce a new Eddy Current Benchmark Problem for the 2014 Review of Progress in Quantitative
More informationA Numerical Study of Depth of Penetration of Eddy Currents
A Numerical Study of Depth of Penetration of Eddy Currents S.Majidnia* a,b, R.Nilavalan b, J. Rudlin a a. TWI Ltd, Cambridge,United Kingdom b Brunel University, London,United Kingdom shiva.majidnia@twi.co.uk
More informationEDDY CURRENT INSPECTION FOR DEEP CRACK DETECTION AROUND FASTENER HOLES IN AIRPLANE MULTI-LAYERED STRUCTURES
EDDY CURRENT INSPECTION FOR DEEP CRACK DETECTION AROUND FASTENER HOLES IN AIRPLANE MULTI-LAYERED STRUCTURES Teodor Dogaru Albany Instruments Inc., Charlotte, NC tdogaru@hotmail.com Stuart T. Smith Center
More informationCOMPUTER MODELING OF EDDY CURRENT TRANSMIT-RECEIVE PROBES FOR. S.P. Sullivan, V.S. Cecco, L.S. Obrutsky, D. Humphrey, S.P. Smith and K.A.
COMPUTER MODELING OF EDDY CURRENT TRANSMIT-RECEIVE PROBES FOR TUBE INSPECTION INTRODUCTION S.P. Sullivan, V.S. Cecco, L.S. Obrutsky, D. Humphrey, S.P. Smith and K.A. Emde Nondestructive Testing Development
More informationModelling of Pulsed Eddy Current Testing of wall thinning of carbon steel pipes through insulation and cladding
Modelling of Pulsed Eddy Current Testing of wall thinning of carbon steel pipes through insulation and cladding S Majidnia a,b, J Rudlin a, R. Nilavalan b a TWI Ltd, Granta Park Cambridge, b Brunel University
More informationEDDY CURRENT TECHNOLOGY FOR HEAT EXCHANGER AND STEAM GENERATOR TUBE INSPECTION
EDDY CUENT TECHNOLOGY FO HEAT EXCHANGE AND STEAM GENEATO TUBE INSPECTION L. Obrutsky, B. Lepine, J. Lu,. Cassidy and J. Carter Atomic Energy of Canada Limited, Chalk iver Laboratories, Chalk iver, Ontario,
More informationMagnetic Eddy Current (MEC) Inspection Technique
Introduction Eddy Current Testing (ECT) is a well established technology for the inspection of metallic components for surface breaking flaws. It is used for component testing in the aviation and automotive
More informationDEEP FLAW DETECTION WITH GIANT MAGNETORESISTIVE (GMR) BASED SELF-NULLING PROBE
DEEP FLAW DETECTION WITH GIANT MAGNETORESISTIVE (GMR) BASED SELF-NULLING PROBE Buzz Wincheski and Min Namkung NASA Langley Research Center Hampton, VA 23681 INTRODUCTION The use of giant magnetoresistive
More informationVD3-71 universal eddy current flaw detector application for field inspection of aeronautical engineering
VD3-71 universal eddy current flaw detector application for field inspection of aeronautical engineering Introduction. The Document reviewed by http://engineermind.com/ By ahmed@engineermind.com The need
More informationApplication of Ultrasonic Guided Wave to Heat Exchanger Tubes Inspection
17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Application of Ultrasonic Guided Wave to Heat Exchanger Tubes Inspection Ik-Keun PARK 1,a, Yong-Kwon KIM 2,b, Sae-Jun PARK
More informationD DAVID PUBLISHING. Eddy Current Test for Detection of Foreign Material using Rotating Probe. 2. Theory. 1. Introduction
Journal of Mechanics Engineering and Automation 6 (2016) 379-383 doi: 10.17265/2159-5275/2016.07.009 D DAVID PUBLISHING Eddy Current Test for Detection of Foreign Material using Rotating Probe Houng Kun
More informationResearch on High Resolution Stress Corrosion Crack Detection Based on Remote Field Eddy Current Non-Destructive Testing
Send Orders for Reprints to reprints@benthamscience.ae The Open Mechanical Engineering Journal, 2015, 9, 339-345 339 Open Access Research on High Resolution Stress Corrosion Crack Detection Based on Remote
More informationA Finite Element Simulation of Nanocrystalline Tape Wound Cores
A Finite Element Simulation of Nanocrystalline Tape Wound Cores Dr. Christian Scharwitz, Dr. Holger Schwenk, Dr. Johannes Beichler, Werner Loges VACUUMSCHMELZE GmbH & Co. KG, Germany christian.scharwitz@vacuumschmelze.com
More informationDetection of Internal OR External Pits from Inside OR Outside a tube with New Technology (EMIT)
Detection of Internal OR External Pits from Inside OR Outside a tube with New Technology (EMIT) Author: Ankit Vajpayee Russell NDE Systems Inc. 4909 75Ave Edmonton, Alberta, Canada T6B 2S3 Phone 780-468-6800
More informationEddy Current Signal Analysis Techniques for Assessing Degradation of Support Plate Structures in Nuclear Steam Generators
ECNDT 2006 - Th.3.1.2 Eddy Current Signal Analysis Techniques for Assessing Degradation of Support Plate Structures in Nuclear Steam Generators Laura OBRUTSKY, Robert CASSIDY, Miguel CAZAL, Ken SEDMAN,
More informationNew inspection approaches for railway based on Eddy Current
New inspection approaches for railway based on Eddy Current More info about this article: http://www.ndt.net/?id=22713 J.L. Lanzagorta 1, J.-M. Decitre 2, F. Nozais 2, I. Aizpurua 1, R. Hidalgo-Gato 1,
More informationEDDY CURRENT MEASUREMENT OF REMOTE TUBE POSITIONS IN CANDU REACTORS S.T. Craig, T.W. Krause, B.V. Luloff and J.J. Schankula Atomic Energy of Canada
EDDY CURRENT MEASUREMENT OF REMOTE TUBE POSITIONS IN CANDU REACTORS S.T. Craig, T.W. Krause, B.V. Luloff and J.J. Schankula Atomic Energy of Canada Limited, Chalk River, Ontario, Canada Abstract: Regular
More informationDEVELOPMENT OF VERY LOW FREQUENCY SELF-NULLING PROBE FOR INSPECTION OF THICK LAYERED ALUMINUM STRUCTURES
DEVELOPMENT OF VERY LOW FREQUENCY SELF-NULLING PROBE FOR INSPECTION OF THICK LAYERED ALUMINUM STRUCTURES Buzz Wincheski and Min Namkung NASA Langley Research Center Hampton, VA 23681 INTRODUCTION Nondestructive
More informationNON-DESTRUCTIVE TESTING OF ARTIFICIAL JOINTS WITH DEFECTS BY EDDY CURRENT METHOD
NON-DESTRUCTIVE TESTING OF ARTIFICIAL JOINTS WITH DEFECTS BY EDDY CURRENT METHOD Andrea Stubendekova 1, Ladislav Janousek 1 1 Department of Electromagnetic and Biomedical Engineering, Faculty of Electrical
More informationDETECTION OF THE SUBSURFACE CRACKS PROPAGATED FROM RIVET HOLES IN THE MULTILAYER AIRCRAFT STRUCTURES
XXIV Seminarium NIENISZCZĄCE BADANIA MATERIAŁÓW Zakopane, 14-16 marca 2018 DETECTION OF THE SUBSURFACE CRACKS PROPAGATED FROM RIVET HOLES IN THE MULTILAYER AIRCRAFT STRUCTURES Valentyn UCHANIN Karpenko
More informationSingle-turn and multi-turn coil domains in 3D COMSOL. All rights reserved.
Single-turn and multi-turn coil domains in 3D 2012 COMSOL. All rights reserved. Introduction This tutorial shows how to use the Single-Turn Coil Domain and Multi-Turn Coil Domain features in COMSOL s Magnetic
More informationNew portable eddy current flaw detector and application examples
11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic New portable eddy current flaw detector and application examples More Info at Open Access Database
More informationAFRL-RX-WP-TP
AFRL-RX-WP-TP-2008-4046 DEEP DEFECT DETECTION WITHIN THICK MULTILAYER AIRCRAFT STRUCTURES CONTAINING STEEL FASTENERS USING A GIANT-MAGNETO RESISTIVE (GMR) SENSOR (PREPRINT) Ray T. Ko and Gary J. Steffes
More informationApplication of Guided Wave Technology to Tube Inspection
ECNDT 2006 - Th.3.1.5 Application of Guided Wave Technology to Tube Inspection T. VOGT, D. ALLEYNE, B. PAVLAKOVIC, Guided Ultrasonics Limited, Nottingham, United Kingdom 1. Introduction Abstract. The inspection
More informationMultivariate Regression Algorithm for ID Pit Sizing
IV Conferencia Panamericana de END Buenos Aires Octubre 2007 Abstract Multivariate Regression Algorithm for ID Pit Sizing Kenji Krzywosz EPRI NDE Center 1300 West WT Harris Blvd. Charlotte, NC 28262 USA
More informationINFLUENCE OF SIGNAL-TO-NOISE RATIO ON EDDY CURRENT SIGNALS OF CRACKS IN STEAM GENERATOR TUBES
http://dx.doi.org/10.5516/net.09.2014.055 INFLUENCE OF SIGNAL-TO-NOISE RATIO ON EDDY CURRENT SIGNALS OF CRACKS IN STEAM GENERATOR TUBES DO HAENG HUR 1*, MYUNG SIK CHOI 1, HEE-SANG SHIM 1, DEOK HYUN LEE
More informationFEM SIMULATION FOR DESIGN AND EVALUATION OF AN EDDY CURRENT MICROSENSOR
FEM SIMULATION FOR DESIGN AND EVALUATION OF AN EDDY CURRENT MICROSENSOR Heri Iswahjudi and Hans H. Gatzen Institute for Microtechnology Hanover University Callinstrasse 30A, 30167 Hanover Germany E-mail:
More informationFirst Validation of CIVA RT Module with a Linear Accelerator in a Nuclear Context
19 th World Conference on Non-Destructive Testing 2016 First Validation of CIVA RT Module with a Linear Accelerator in a Nuclear Context D. TISSEUR 1, Bernard RATTONI 1, Caroline VIENNE 1, Ronan GUILLAMET
More informationBE. Electronic and Computer Engineering Final Year Project Report
BE. Electronic and Computer Engineering Final Year Project Report Title: Development of electrical models for inductive coils used in wireless power systems Paul Burke 09453806 3 rd April 2013 Supervisor:
More informationINVESTIGATION OF IMPACT DAMAGE OF CARBON FIBER- RAINFORCED PLASTIC (CFRP) BY EDDY CURRENT NON- DESTRUCTIVE TESTING
International Workshop SMART MATERIALS, STRUCTURES & NDT in AEROSPACE Conference NDT in Canada 2011 2-4 November 2011, Montreal, Quebec, Canada INVESTIGATION OF IMPACT DAMAGE OF CARBON FIBER- RAINFORCED
More informationDetecting 1 st and 2 nd Layer Simulated Cracks in Aircraft Wing Spanwise Splice Standards Using Remote-Field Eddy Current Technique
Detecting 1 st and Layer imulated Cracks in Aircraft Wing panwise plice tandards Using Remote-Field Eddy Current Technique Yushi un, Tianhe Ouyang Innovative Materials Testing Technologies, Inc. 251 N.
More informationArray Eddy Current for Fatigue Crack Detection of Aircraft Skin Structures
Array Eddy Current for Fatigue Crack Detection of Aircraft Skin Structures Eric Pelletier, Marc Grenier, Ahmad Chahbaz and Tommy Bourgelas Olympus NDT Canada, NDT Technology Development, 505, boul. du
More informationHeat Exchanger & Boiler Tube Inspection Techniques
Overview For the in-service inspection of ferromagnetic, non-ferromagnetic and fin-fan tubes, the following advanced techniques offer high defect detection capabilities and accurate defect analysis: Multiple
More informationEDDY CURRENT TESTING
NEW SOUTH WALES TECHNICAL AND FURTHER EDUCATION COMMISSION EDDY CURRENT TESTING NSW Module Number: Implementation Date: 6161C 01-Jan-1998 National Module Code: EA605 MANUFACTURING AND ENGINEERING MECHANICAL
More informationEMAT Application on Incoloy furnace Tubing Ramamohan Reddy M (ASNT Level III UT, PCN Level III UT,PAUT&TOFD)
EMAT Application on Incoloy furnace Tubing By Ramamohan Reddy M (ASNT Level III UT, PCN Level III UT,PAUT&TOFD) Outlines 1. Introduction EMAT 2. EMAT- Ultrasound waves 3. EMAT-Surface waves 4. EMAT-Guided
More informationDETECTION OF SUB LAYER FATIGUE CRACKS UNDER AIRFRAME RIVETS
DETECTION OF SUB LAYER FATIGUE CRACKS UNDER AIRFRAME RIVETS Buzz Wincheski and Min Namkung NASA Langley Research Center Hampton, VA 23681 INTRODUCTION The Rotating Self-Nulling Probe System developed as
More informationCorrosion Steel Inspection under Steel Plate Using Pulsed Eddy Current Testing
4th International Symposium on NDT in Aerospace 2012 - Poster 4 Corrosion Steel Inspection under Steel Plate Using Pulsed Eddy Current Testing D.M. SUH *, K.S. JANG **, J.E. JANG **, D.H. LEE ** * Raynar
More informationComparison of Leakage Impedances of Two Single-phase Transformers
Aim Comparison of Leakage Impedances of Two Single-phase Transformers To understand the effect of core construction on leakage impedance in a single-phase transformers To understand factors affecting leakage
More informationCIRCULAR PHASED ARRAY PROBES FOR INSPECTION OF SUPERPHOENIX STEAM GENERATOR TUBES
CIRCULAR PHASED ARRAY PROBES FOR INSPECTION OF SUPERPHOENIX STEAM GENERATOR TUBES G. Fleury, J. Poguet Imasonic S.A. France O. Burat, G Moreau Framatome France Abstract An ultrasonic Phased Array system
More informationDual Core Differential Pulsed Eddy Current Probe to Detect the Wall Thickness Variation in an Insulated Stainless Steel Pipe
Journal of Magnetics 15(4), 204-208 (2010) DOI: 10.4283/JMAG.2010.15.4.204 Dual Core Differential Pulsed Eddy Current Probe to Detect the Wall Thickness Variation in an Insulated Stainless Steel Pipe C.
More informationNumerical Simulation of PCB-Coil-Layouts for Inductive Energy Transfer
Numerical Simulation of PCB-Coil-Layouts for Inductive Energy Transfer Systems David Maier *, Normen Lucht, Alexander Enssle, Anna Lusiewicz, Julian Fischer, Urs Pecha, Prof. Dr.-Ing. Nejila Parspour University
More informationThe Battle of Carbon Steel
More info ab The Battle of Carbon Steel Advantages of Eddy Current Array over Magnetic Particle and Penetrant Testing for Inspecting the Surface of Carbon Steel Welds Terence Burke Product Application
More informationAFRL-RX-WP-TP
AFRL-RX-WP-TP-2011-4404 MODEL BASED STUDIES OF THE SPLIT D DIFFERENTIAL EDDY CURRENT PROBE (PREPRINT) Jeremy Knopp and Mark Blodgett Metals, Ceramics & Nondestructive Evaluation Division (AFRL/RXLP) R.D.
More informationFERROUS TUBING PROBES
2018 PRODUCT CATALOG FERROUS TUBING PROBES Ferrous Tubing Probe Selector Matrix Material Non- ferromagnetic Low Ferromagnetic Ferromagnetic Type Aluminum finned tube ECT ECA IRIS RFT NFT MFL Selection
More informationSimulation of ultrasonic guided wave inspection in CIVA software platform
18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa Simulation of ultrasonic guided wave inspection in CIVA software platform Bastien CHAPUIS 1, Karim JEZZINE 1, Vahan
More informationLASER-BASED NDT OF TITANIUM AIRCRAFT ENGINE COMPONENTS J. Doyle Jr and M. J. Brinkman Laser Techniques Company, LLC, Bellevue, USA
LASER-BASED NDT OF TITANIUM AIRCRAFT ENGINE COMPONENTS J. Doyle Jr and M. J. Brinkman Laser Techniques Company, LLC, Bellevue, USA Abstract: Assuring the integrity of high-energy rotating parts in aircraft
More informationEddy Current Array for Aerospace
NANDT Conference 2017 Eddy Current Array for Aerospace Presented by Richard Nowak Olympus Product Manager NDT Material provided by Ghislain Morais, OSSA Eddy Current Array ECA Instrument OmniScan ECA:
More informationAdhesive Thickness Measurement on Composite Aerospace Structures using Guided Waves
19 th World Conference on Non-Destructive Testing 2016 Adhesive Thickness Measurement on Composite Aerospace Structures using Guided Waves Laura TAUPIN 1, Bastien CHAPUIS 1, Mathieu DUCOUSSO 2, Frédéric
More informationFLAW DETECTION USING ENCIRCLING COIL EDDY CURRENT SYSTEMS
DATA SHEET NO GI-2 Magnetic Analysis Corporation FLAW DETECTION USING ENCIRCLING COIL EDDY CURRENT SYSTEMS PRINCIPLES OF OPERATION The detection of flaws such as seams, cracks, pits, slivers, weld-line
More informationDETECTION OF CORROSION IN BOTTOM PLATES OF GAS AND OIL TANKS USING GUIDED ULTRASONIC WAVES AND ELECTROMAGNETIC ULTRASONIC (EMAT) TRANSDUCERS
DETECTION OF CORROSION IN BOTTOM PLATES OF GAS AND OIL TANKS USING GUIDED ULTRASONIC WAVES AND ELECTROMAGNETIC ULTRASONIC (EMAT) TRANSDUCERS A Presentation prepared for the Jahrestagung der Deutsche Gesellschaft
More informationTesting Critical Medical Tubing Using High Frequency Eddy Current Coils
Testing Critical Medical Tubing Using High Frequency Eddy Current Coils Troy M Libby Magnetic Analysis Corporation, Mt. Vernon, NY, USA Phone: (914) 699-9450, Fax: (914) 699-9837; e-mail: info@mac-ndt.com
More informationAA&S Conference 2018 Eddy Current Array for Aircraft
AA&S Conference 2018 Eddy Current Array for Aircraft Presented by Graham Maxwell Olympus Australia NDT Key Account Manager Material provided by Ghislain Morais Olympus NDT Canada Eddy Current Array ECA
More informationElectromagnetic Wave Analysis of Waveguide and Shielded Microstripline 1 Srishti Singh 2 Anupma Marwaha
Electromagnetic Wave Analysis of Waveguide and Shielded Microstripline 1 Srishti Singh 2 Anupma Marwaha M.Tech Research Scholar 1, Associate Professor 2 ECE Deptt. SLIET Longowal, Punjab-148106, India
More informationDEEP PENETRATING EDDY CURRENT for DETECTING VOIDS in COPPER
DEEP PENETRATING EDDY CURRENT for DETECTING VOIDS in COPPER Tadeusz Stepinski (Uppsala University, Signals and System, P.O.Box 528, SE-75 2 Uppsala, Sweden, ts@signal.uu.se) Abstract Assessment of copper
More informationDetecting Compressive Residual Stress in Carbon Steel Specimens of Flat Geometries Using the Remote-Field Eddy Current Technique
Detecting Compressive Residual Stress in Carbon Steel Specimens of Flat Geometries Using the Remote-Field Eddy Current Technique Y. Sun and T. Ouyang Innovative Materials Testing Technologies, Inc. 2501
More informationNovel Demagnetization Method after Magnetic Particle Testing
Novel Demagnetization Method after Magnetic Particle Testing Takuhiko Ito, Arihito Kasahara and Michitaka Hori More info about this article: http://www.ndt.net/?id=22254 Nihon Denji Sokki Co., LTD, 8-59-2
More informationA Method for Quantitative Analysis of Transient Eddy Current Testing
NDT in Canada 2016 & 6th International CANDU In-Service Inspection Workshop, Nov 15-17, 2016, Burlington, ON (Canada) www.ndt.net/app.ndtcanada2016 A Method for Quantitative Analysis of Transient Eddy
More informationEXTREME LOW FREQUENCY MAGNETIC IMAGING METHOD FOR DETECTION OF. Katsumi INOUE 2)
EXTREME LOW FREQUENCY MAGNETIC IMAGING METHOD FOR DETECTION OF DEFECT INSIDE WELDING PARTS OF IRON PLATE Keiji TSUKADA 1), Teruki HASEGAWA 1), Mituteru YOSHIOKA 1), Toshihiko KIWA 1), Katsumi INOUE 2)
More informationA Portable Magnetic Flux Leakage Testing System for Industrial Pipelines Based on Circumferential Magnetization
19 th World Conference on Non-Destructive Testing 2016 A Portable Magnetic Flux Leakage Testing System for Industrial Pipelines Based on Circumferential Magnetization Kunming ZHAO 1, Xinjun WU 1, Gongtian
More informationPORTABLE EDDY CURRENT FLAW DETECTOR VD3-71 NK-IVU.
PORTABLE EDDY CURRENT FLAW DETECTOR VD3-71 NK-IVU www.ndt.com.ua PURPOSE FLAW DETECTOR ADVANTAGES VD3-71 eddy current flaw detector is rated among the means of flaw detectors testing and evaluation and
More informationEquivalent current models and the analysis of directional ECT signals
E-Journal of Advanced Maintenance Vol.7-2 (2015) 179-188 Japan Society of Maintenology Equivalent current models and Weiying CHENG 1,* 1 NDE Center, Japan Power Engineering and Inspection Corporation,
More informationDESIGN AND VALIDATION OF NOVEL ELECTRICALLY ROTATING EDDY CURRENT PROBES
DESIGN AND VALIDATION OF NOVEL ELECTRICALLY ROTATING EDDY CURRENT PROBES By Chaofeng Ye A DISSERTATION Submitted to Michigan State University in partial fulfillment of the requirements for the degree of
More informationNew Multi-Technology In-Line Inspection Tool For The Quantitative Wall Thickness Measurement Of Gas Pipelines
New Multi-Technology In-Line Inspection Tool For The Quantitative Wall Thickness Measurement Of Gas Pipelines A. Barbian 1, M. Beller 1, F. Niese 2, N. Thielager 1, H. Willems 1 1 NDT Systems & Services
More informationCHAPTER 2 ELECTROMAGNETIC FORCE AND DEFORMATION
18 CHAPTER 2 ELECTROMAGNETIC FORCE AND DEFORMATION 2.1 INTRODUCTION Transformers are subjected to a variety of electrical, mechanical and thermal stresses during normal life time and they fail when these
More informationPerformance of UT Creeping Waves in Crack Sizing
17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Performance of UT Creeping Waves in Crack Sizing Michele Carboni, Michele Sangirardi Department of Mechanical Engineering,
More informationRFC EDDY CURRENT PROBE TESTS. Wally C. Hoppe and David A. Stubbs
RFC EDDY CURRENT PROBE TESTS INTRODUCTION Wally C. Hoppe and David A. Stubbs NDE Systems Division SYSTEMS RESEARCH LABORATORIES, INC. 2800 Indian Ripple Road Dayton, Ohio 45440 An automated, computer controlled
More informationMODELLING AND EXPERIMENTS FOR THE DEVELOPMENT OF A GUIDED WAVE LIQUID LEVEL SENSOR
Proceedings of the National Seminar & Exhibition on Non-Destructive Evaluation NDE 2011, December 8-10, 2011 MODELLING AND EXPERIMENTS FOR THE DEVELOPMENT OF A GUIDED WAVE LIQUID LEVEL SENSOR Subhash N.N
More informationEvaluation of Crack Depth Using Eddy Current Techniques with GMR-based Probes
Evaluation of Crack Depth Using Eddy Current Techniques with GMR-based Probes Ruben Menezes, Artur L. Ribeiro, Helena G. Ramos Instituto de Telecomunicações, Instituto Superior Técnico Universidade de
More informationULTRASONIC GUIDED WAVE FOCUSING BEYOND WELDS IN A PIPELINE
ULTRASONI GUIDED WAVE FOUSING BEYOND WELDS IN A PIPELINE Li Zhang, Wei Luo, Joseph L. Rose Department of Engineering Science & Mechanics, The Pennsylvania State University, University Park, PA 1682 ABSTRAT.
More informationSignal Processing in an Eddy Current Non-Destructive Testing System
Signal Processing in an Eddy Current Non-Destructive Testing System H. Geirinhas Ramos 1, A. Lopes Ribeiro 1, T. Radil 1, M. Kubínyi 2, M. Paval 3 1 Instituto de Telecomunicações, Instituto Superior Técnico
More informationInduction heating of internal
OPTIMAL DESIGN OF INTERNAL INDUCTION COILS The induction heating of internal surfaces is more complicated than heating external ones. The three main types of internal induction coils each has its advantages
More informationDIAGNOSTIC OF CORROSION DEFECTS IN STEAM GENERATOR TUBES USING ADVANCED SIGNAL PROCESSING FROM EDDY CURRENT TESTING
2009 International Nuclear Atlantic Conference - INAC 2009 Rio de Janeiro,RJ, Brazil, September27 to October 2, 2009 ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR - ABEN ISBN: 978-85-99141-03-8 DIAGNOSTIC OF
More informationNDT-PRO Services expands service offering
NDT-PRO Services expands service offering NDT-PRO Services announced the formal release of two advanced NDT methods, Phased Array (including TOFD) and Eddy Current. What are they and where are the used?
More informationwarwick.ac.uk/lib-publications
Original citation: Hughes, F., Day, R., Tung, N. and Dixon, Steve. (2016) High-frequency eddy current measurements using sensor-mounted electronics. Insight- Non-Destructive Testing & Condition Monitoring,
More informationHigh-Precision Internal Diameter Measurements Using Eddy Current Arrays
17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China High-Precision Internal Diameter Measurements Using Eddy Current Arrays Benoit LEPAGE 1, Dave KATZ 2,Simon LABBE 1, 1 Olympus
More informationPRACTICAL ENHANCEMENTS ACHIEVABLE IN LONG RANGE ULTRASONIC TESTING BY EXPLOITING THE PROPERTIES OF GUIDED WAVES
PRACTICAL ENHANCEMENTS ACHIEVABLE IN LONG RANGE ULTRASONIC TESTING BY EXPLOITING THE PROPERTIES OF GUIDED WAVES PJ Mudge Plant Integrity Limited, Cambridge, United Kingdom Abstract: Initial implementations
More information