1 Module 7: IPSTAR Uplink Access Test (IUAT) Ground System Training Department Standard (iuat1.14)-uti-101 THAICOM Public Company Limited
2 Module Objectives At the end of the module the participant shall be able to: Describe the importance of IUAT process. Use IUAT program to run IUAT process. Explain the meaning of messages displayed in IUAT program while running IUAT process.
3 Topics Introduction to IUAT process IUAT program installation IUAT process Information required for IUAT process IUAT mode REF: 10 m length reference cable IUAT mode ACT: Actual length cable UAT QC Parameters
4 Introduction to IUAT process
5 What does IUAT process do? Help to align the antenna to achieve the best quality of received and transmitted signal of UT. Calibrate the most suitable transmission power of UT. Verify whether the received and transmitted signal quality met the calculated reference level at each installed location.
6 When we need to do IUAT? New UT installation UT component replacement which include feed assembly (BUC and LNB), cable, attenuator and IDU ODU relocation UT regular maintenance
7 IUAT program At the UT installation site, installer needs the iuat program to run IUAT process. IUAT program
8 IUAT program installation
9 Setup file Double click on setup file to install iuat program.
10 Microsoft.NET Framework If your computer didn't have.net framework, program will ask you to install.net framework. Click "Accept to automatically install to your computer. After installation finish, regular installation of iuat 1.16 program will start. If your computer already has Microsoft If your computer already has Microsoft.NET Framework, the installation of iuat 1.16 program will start right away.
11 Installation on progress
12 Open iuat program The shortcut of iuat program will automatically appear on the desktop. Double click on iuat1.16 to open iuat program.
13 Information required before running IUAT
14 Information required before running IUAT Installer ID and Password Installation Job order Frequency profile
15 1. Installer ID and Password IUAT process shall be performed by only authorized installer. Installer ID and password will be given to installer after passing UT installation training.
16 2. Installation job order Job ID Created from Webpro by Service provider and sent to installer Authorize key Parameters to input in IUAT program Job ID Authorize key Frequency profile Frequency profile
17 3. Frequency profile Frequency profile contains information of received frequency for each beam. Installer should check on the latest frequency profile with Service provider. Frequency Profile
18 Loading frequency profile 1. Click on Load Profile.
19 Loading frequency profile (Cont.) 2. Select frequency profile 3. Click Open
20 Loading frequency profile (Cont.) 4. Click Yes
21 Loading frequency profile (Cont.) 5. Click OK
22 IUAT process
23 Mode in IUAT IUAT program can run in 2 modes. REF mode : Reference 10 m length cable mode ACT mode : Actual length cable mode Purpose of REF mode To help installer to align antenna by using not too long cable. Installer can know the quality of received and transmitted signal when using the cable that he knows the cable loss. Purpose of ACT mode To calibrate the transmission power of UT when using the actual cable. For new installation, it is recommended to run IUAT process with both REF mode and ACT mode.
24 Work flow of IUAT process Start Insert Tx optimizer/attenuator IUAT process : REF mode Connect to IDU. FAIL Quality Control IUAT process : ACT mode ** No need to align antenna PASS Place IDU inside the building and wire actual cable inside the building. FAIL Quality Control PASS Finish
25 IUAT process consists of 8 steps as follows. Step 1 : Authentication Step 2 : ODU Information Step 3 : Terminal Connecting Step 4 : Antenna Alignment Step 5 : Searching for TOLL frequency Step 6 : Transmitted Power Calibration Step 7 : Polarization Alignment Step 8 : Quality Control
26 IUAT : mode REF (Reference 10 m length cable)
27 MODE : REF Step 1 : Authentication Fill in authorized information as follows: 1. Installer ID 2. Password 3. Job ID: (from job order) 4. Authorization Code: (from job order) Click Next
28 MODE : REF Step 1 : Authentication (Cont.) Installer can input more accurate location using latitude and longitude obtained from GPS by clicking on the Specify location check box and then enter latitude and longitude. Click Next
29 MODE : REF Step 1 : Authentication (Cont.) After clicking Next. Program will ask if the installer is using 10 m reference cables. Click yes to proceed to REF mode of IUAT process. Click Yes
30 Recover of Last Information Entered Click on Keys icon to recover the last information entered.
31 MODE : REF Step 2 : ODU information Fill in ODU information as the following: 1. Antenna and BUC size 2. BUC & LNB S/N (Serial Number) and Model are labeled on the equipments. 3. The recommended cable type is RG-6 or RG Cable MFG (Manufacturer) information 5. Uncheck Default checkbox and select new LNB local frequency required for that UT if the actual LNB LO frequency is different from the default value. 6. Enter value of Tx&Rx optimizer/attenuator if used. 7. Click Next to continue. Information will be recorded in the system and will be useful for problem investigation in case there is problem on that UT after installation. Click Next
32 MODE : REF Step 3 : Terminal connecting Enter Terminal IP address which is LAN IP address of IDU. Default logon power is set at -20 dbm. Click Next to continue to the next step. Click Next
33 MODE : REF Step 3 : Terminal connecting (Cont.) Waiting for profile setting : IDU is downloading information from frequency profile.
34 MODE : REF Step 4 : Antenna alignment Hardware Initializing : IDU is being initialized.
35 MODE : REF Step 4 : Antenna alignment (Cont.) Installer performs antenna alignment by adjusting Az, El, and Pol angles of antenna until maximum TOLL Es/No is found. Current Rx level Max Rx level TOLL Es/No Beam ID Freq ID
36 MODE : REF Step 4 : Antenna alignment (Cont.) Parameters in Step 4: Antenna alignment Parameter Current Rx level Max Rx level TOLL Es/No Beam ID Freq ID Description Level of received signal while adjusting AZ, EL and POL angle. Maximum level of received signal obtained during antenna alignment. Level of TOLL Es/No received in db ID number as in frequency profile to represent the actual beam number ID number as in frequency profile to represent the received frequency for TOLL of the related beam
37 Change Text Color For better readability, color of displayed text can be changed by clicking Color icon selecting the box that required changing choosing the color (recommend yellow color) clicking OK
38 Resizable Dialog box Program dialog box can be resized by placing the mouse cursor over the edge of the dialog box and move to adjust the size.
39 MODE : REF Step 4 : Antenna alignment (Cont.) 1 Before adjusting antenna in this step, the AZ, EL and POL angle should be preadjusted according to the job order Sweep antenna in Azimuth (AZ) direction until the received signal is found, and TOLL Es/No is detected. Continue to scan for the maximum TOLL Es/No in Azimuth direction. Note: If the desired signal is not found increase or decrease elevation setting by 1 degree and repeat azimuth sweep. 2. Slowly adjust Elevation (EL) angle to achieve higher TOLL Es/No. **Alternately adjust Elevation (EL) and Azimuth (AZ) until maximum TOLL Es/No is obtained.
40 MODE : REF Step 4 : Antenna alignment (Cont.) Adjust polarization angle to obtain the maximum TOLL Es/No. 1.2m For 1.2m antenna, polarization angle is adjusted by rotating feed assembly. For 84cm antenna, polarization angle is adjusted by rotating antenna reflector m
41 MODE : REF Step 4 : Antenna alignment (Cont.) After adjusting AZ, EL and POL angle, click next to proceed to the next step. Click Next
42 MODE : REF Step 5 : Searching for TOLL frequency TOLL Scanning : UT automatically scans TOLL carrier to get signal for synchronization.
43 MODE : REF Step 5 : Searching for TOLL frequency (Cont.) Waiting for Synchronization : UT is about to synchronize with the gateway.
44 MODE : REF Step 6 : Transmitted Power Calibration UT is automatically searching for UAT channel. When UAT channel is found, UT will obtain the necessary information e.g., frequency for sending logon request to the gateway.
45 MODE : REF Step 6 : Transmitted Power Calibration (Cont.) UT searches for logon frequency and sends logon request to the gateway. Logon Accepted means IPSTAR gateway already accepts logon request.
46 Re-login of Installer ID and/or Password If installer keys in wrong installer ID and/or Password, iuat1.16 allow re-login of installer ID and/or Password up to 3 trials without restart IUAT from Step 1. This feature will be active when use IUAT 1.16 with TIS version or higher.
47 MODE : REF Step 6 : Transmitted Power Calibration (Cont.) Tx Power Cal : Transmission power of UT is being calibrated.
48 MODE : REF Step 7 : Polarization alignment Polarization adjustment at transmission part in order to avoid making interference to other satellites.
49 MODE : REF Step 7 : Polarization alignment (Cont.) This step is to maximize the transmitted signal level at Co-polarization and minimize the interference from the Cross-polarization. Signal lev vel Cross-polarization Co-polarization Polarization angle
50 MODE : REF Step 7 : Polarization alignment (Cont.) 15.5 Signal level Step A) Find the maximum Aloha STAR EsNo. Polarization angle Ex. Maximum value of Aloha STAR EsNo = 15.5 **** This maximum value might not be at the minimum cross polarization.
51 MODE : REF Step 7 : Polarization alignment (Cont.) A A Step B) Rotate in CW direction until ALOHA STAR EsNo decreases from the maximum value by 1.5dB. Make a mark on the side of the feed horn. While you are making a mark, the timer will count 20sec. (Position A) After the countdown clock is done, iuat program will display message telling installer to rotate in the other direction.
52 MODE : REF Step 7 : Polarization alignment (Cont.) A A B B Step C) Rotate in CCW direction until ALOHA STAR EsNo pass the maximum value and reaches the value of "1.5dB" dropped from the maximum value again. Make another mark on the side of the feed horn. While you are making a mark, the timer will count 20sec (Position B). After the countdown clock is done, iuat program will display message telling installer to adjust copol to the center of green area.
53 MODE : REF Step 7 : Polarization alignment (Cont.) C A A B C B Step D) Rotate the feed assembly to the middle point (Position C) between position A and position B. Tighten the 2 bolts at the feed clamp.
54 MODE : REF Step 7 : Polarization alignment (Cont.) After POL angle adjustment, click Next to proceed to the next step. Click Next
55 MODE : REF Step 7 : Polarization alignment (Cont.) The program will ask to do IUAT QC. Click Yes to continue. Click Yes
56 MODE : REF Step 8 : Quality control Link information is sent to the gateway.
57 MODE : REF Step 8 : Quality control (Cont.) Parameters in IUAT result (REF mode) e.g., Tx gain, Max gain, TOLL Es/No, STAR Es/No and Delta will be displayed on the left side. It will show TOLL PASS, STAR PASS, and Delta PASS if TOLL Es/No, STAR Es/No and Delta Power to Max are higher than the reference values at that particular installation location. IUAT results (REF mode)
58 MODE : REF Step 8 : Quality control (Cont.) Close IUAT program after IUAT program shows IUAT successful. IUAT process (REF mode) is successfully completed. Click here to close IUAT program.
59 IUAT : mode ACT (Actual length cable)
60 IUAT : Mode ACT The main purpose of IUAT ACT mode is to calibrate transmission power of UT when using the actual cable. 8 steps of IUAT process will be repeated as in REF mode but there is no need to adjust look up angle again since it is already done in IUAT REF mode. Before proceeding to IUAT mode ACT Place IDU in the building at the actual using place. Wire the actual cable inside the building Insert Tx optimizer/attenuator Connect to IDU.
61 MODE : ACT : Step 0 Select the existing job Open IUAT program again and select Existing Job which is the same Job ID as REF mode. Click Next to proceed to the next step. Click Next
62 MODE : ACT : Step 2 : ODU information Fill in the information of the actual cable. 1. Cable type 2. Cable length 3. Cable MFG (Manufacturer) 4. Tx & Rx Optimizer/Attenuator if used Click Next to proceed to the next step. Click Next
63 MODE : ACT Step 3 : Terminal connecting Enter Terminal IP address which is LAN IP address of IDU. Select Logon power which can be adjusted to compensate the loss in actual cable. Click Next to proceed to the next step. Click Next
64 MODE : ACT Step 4 : Antenna alignment In step 4 of ACT mode, installer does not have to adjust AZ, EL and POL angle again. Click next to proceed to the next step. Click Next
65 Checking if Rx Attenuator is required In Step 4 of ACT mode, the program will automatically check the current Rx level. If the current Rx level is higher than 100 which is exceeding the saturation point of IDU, IUAT will not proceed to the next step. Rx signal strength saturated message will be displayed asking to install Rx optimizer/attenuator. Current Rx level > 100 Click OK Click OK to close IUAT program. Turn off IDU and insert Rx attenuator. Then, start running IUAT process: ACT mode again.
66 MODE : ACT Step 5 : Searching for TOLL frequency TOLL Scanning and Waiting for Synchronization will run automatically by IUAT program.
67 MODE : ACT Step 6 : Transmitted Power Calibration UT will automatically proceed to logon to the gateway.
68 MODE : ACT Step 6 : Transmitted Power Calibration (Cont.) Tx Power Cal: Transmission power of UT using actual cable is being calibrated.
69 Checking if Tx Attenuator is required In Step 6 of ACT mode, if the UT s transmission power is higher than the maximum value of the range required in IPSTAR system (-15 db) after Tx power calibration, IUAT will not proceed to the next step. Tx gain exceeded message will be displayed asking to remove Tx optimizer/ attenuator. Click OK Click OK to close IUAT program. Turn off IDU and remove Tx optimizer/attenuator. Then, start running IUAT process: ACT mode again.
70 MODE : ACT Step 7 : Polarization Adjustment In Step 7 of ACT mode, installer does not have to adjust POL angle again. Click next to proceed to the next step. Click Next
71 MODE : ACT Step 7 : Polarization Adjustment (Cont.) Program will ask to do IUAT QC. Click Yes to continue. Click Yes
72 MODE : ACT Step 8 : Quality control Link information is sent to the gateway.
73 MODE : ACT Step 8 : Quality control (Cont.) IUAT results in ACT mode (e.g., TX Gain, Max Gain, TOLL Es/No, STAR Es/No and Delta) will be displayed on the right side of the table. It will show TOLL PASS, STAR PASS, and Delta PASS if TOLL Es/No, STAR Es/No, and Delta Power to Max are higher than the reference values at that particular installation location. Click Confirm to confirm IUAT QC results within 60 seconds. IUAT result (ACT mode) Click Confirm
74 MODE : ACT Step 8 : Quality control (Cont.) IUAT program automatically updates IUAT results to the gateway.
75 MODE : ACT Step 8 : Quality control (Cont.) IUAT process (ACT mode) is successfully completed. Installer can close the iuat program.
76 UAT QC parameters
77 UAT QC parameters The quality of IUAT can be evaluated from 5 parameters. Max gain Tx gain Delta TOLL Es/No STAR Es/No
78 QC Delta Power to Max IUAT1.16 can support QC data for Delta Power to Max value. This option will be active when Terminal Installation Server (TIS) version or higher is used.
79 TOLL Es/No (db) TOLL Es/No indicates the quality of TOLL carrier received by UT. TOLL Es/No in UAT QC result should to be the same as the TOLL Es/No obtained from IUAT step 4: Antenna Alignment. To pass UAT QC, TOLL Es/No must be higher than the reference TOLL Es/No at the UT s location. TOLL: PASS must be shown in UAT QC result.
80 STAR Es/No (db) STAR Es/No indicates the quality of STAR carrier received by IPSTAR gateway. In UAT QC, STAR Es/No is the signal quality when UT transmits at the maximum transmission power. To pass UAT QC, STAR Es/No must be higher than the reference STAR Es/No at the UT s location. STAR: PASS must be shown in UAT QC result.
81 Tx Gain (db) and Max Gain (db) Tx Gain and Max Gain are the proper operating point of IDU s transmission power selected in step 6 of IUAT: Transmitted Power Calibration. Tx Gain is the IDU s transmission power when it logs-on to IPSTAR system. Max Gain is the maximum IDU s transmission power allowed for IDU to transmit. The operating point of Tx Gain required in IPSTAR system is in the range between -33 db and -15 db. -33 db < Tx Gain < -15 db The value of Tx Gain and Max Gain depends on the location of UT, antenna size, gain of BUC, cable length and Tx attenuator insertion.
82 Delta Power to Max (db) By definition, Delta Power to Max is the range between Tx Gain and Max Gain. Delta Power to Max (db) = Max Gain (db) Tx Gain (db) It indicates the amount of additional transmission power from Tx Gain that IDU can transmit. The proper Delta Power to Max value depends on the location of UT, antenna size (m) and BUC size (Watt).
83 Delta Power to Max (db) - Continue Proper value of Delta Power to Max at the center, 50% contour, and EOC of an IPSTAR spot beam (207) for antenna size 0.84m, 1.2m and 1.8m Contour 1W BUC Antenna 0.84m 1.2m 1.8m 2W BUC 1W BUC 2W BUC 1W BUC 2W BUC Center % Contour EOC
84 Delta Power to Max (db) Continue With the same antenna size (m) and BUC size (Watt): UT in the center of IPSTAR spot beam will have more Delta Power to Max than the UT in the edge of IPSTAR spot beam or shape beam. 1.2m Antenna: In the center of an IPSTAR spot beam, the UT with 1.2m antenna and 1 W BUC should have Delta Power to Max at least 17 db. In the edge of an IPSTAR spot beam, the UT with 1.2m antenna and 1 W BUC should have Delta Power to Max at least 9 db. 0.84m Antenna: In the center of an IPSTAR spot beam, the UT with 0.84m antenna and 1 W BUC should have Delta Power to Max at least 15 db. In the edge of an IPSTAR spot beam, the UT with 0.84m antenna and 1 W BUC should have Delta Power to Max at least 8 db.
85 Delta Power to Max (db) Continue With the same location and BUC size (Watt): UT with bigger antenna size will have more Delta Power to Max than UT with smaller antenna size. With the same location and antenna size (m): UT with higher BUC size will have more Delta Power to Max than UT with lower BUC size.
86 Special Options of IUAT
87 Special Options IUAT1.16 has 4 new options that can reduce time for IUAT process. If special criteria meet, installer can click Option and select the special option(s). Click Option
88 1. Check UT s Configuration This option will reduce the process of rebooting UT and waiting for profile setting around 70 seconds. With this option, IUAT will check two conditions. Is Rx Frequency (L-Band) in current IDU configuration same as current Frequency profile in IUAT? Is 10 MHz BUC Reference Disabled in Satellite tab in xwebgateway unchecked? If the answers for both questions are Yes, IUAT will skip Waiting for Profile Setting and proceed with Hardware initialization. If one of the answers or both answers are No, IUAT will take 70s for Waiting for Profile If one of the answers or both answers are No, IUAT will take 70s for Waiting for Profile Setting.
89 2. Skip TOLL Scanning Feature With this option, iuat program will save time in scanning TOLL frequency. This option can be used when No overlap beam Fix beam on Job Order iuat will use the default TOLL frequency for the beam specified in Job Order.
90 3. Rx Level Sensitivity With this option, IUAT will use Median filter algorithm to get rid of overshoot/undershoot signal. If Rx level sensitivity is set to be Fast, IUAT will collect less data causing overshoot of signal. If Rx level sensitivity is set to be Slow, IUAT will collect more data showing smoother and less fluctuation signal.
91 4. Expand TOLL Tracking Frequency Range This option will solve LNB LO frequency shifting problem. IUAT will expand TOLL tracking frequency range to 1MHz (500kHz on each side). The procedures for IUAT frequency shifting are: Start with F0 (center frequency). If F0 cannot synchronization, change to F kHz. If F K cannot synchronization, change to F0 500kHz.
92 Quiz 1. What is the importance of IUAT process? A. Help to align the antenna to achieve the best quality of received and transmitted signal of UT. B. Calibrate the most suitable transmission power of IDU. C. Verify whether the received and transmitted signal quality met the calculated reference level at each location. D. All of the above 2. Installer does not need to run IUAT in which case below? A. New UT installation B. Changing Tx or Rx cable C. Changing Tx Optimizer/attenuator D. Changing IP address of UT
93 Quiz (Continue) 3. What authorized information should be obtained before running IUAT? A. Installer ID and Password B. Job ID C. Authorization code D. All of the above 4. What does installer have to do in step 4 of IUAT program? A. Adjust AZ, EL and POL angle to achieve maximum STAR Es/No. B. Adjust AZ, EL and POL angle to achieve maximum TOLL Es/No. C. Calibrate transmission power of UT. D. Click confirm IUAT result.
94 Quiz (Continue) 5. Which statement is true regarding step 6 of IUAT program? A. In step 6, UT automatically scans TOLL carrier to get signal for synchronization. B. In step 6, transmission power of UT is being calibrated. C. In step 6, installer has to adjust AZ, EL and POL angle. D. In step 6, IDU is downloading information from frequency profile. 6. Which statement is incorrect? A. Tx Gain is the maximum IDU s transmission power allowed for IDU to transmit. B. The operating point of Tx Gain required in IPSTAR system is in the range between -33 db and -15 db. C. Delta Power to Max indicates the amount of additional transmission power from Tx Gain that IDU can transmit. D. In the center of an IPSTAR spot beam, UT with 1.2m antenna and 1 W BUC should have Delta Power to Max at least 16-17dB.
95 Quiz (Continue) 7. Assume that Reference TOLL Es/No = 12 db and Reference STAR Es/No = 20 db, which case the IUAT program will allow UT to pass QC if installer get below TOLL Es/No and STAR Es/No? A. TOLL Es/No = 12.1 db STAR Es/No = 19 db B. TOLL Es/No = 11 db STAR Es/No = 20.1 db C. TOLL Es/No = 12.1 db STAR Es/No = 20.1 db D. TOLL Es/No = 11 db STAR Es/No = 19 db
96 Quiz (Continue) 8. Comparing the IUAT result of 2 installers who install UT at the same location and use the same type of UT, which one perform better installation? Installer A Tx gain = db Max gain = -5.3 db Installer B Tx gain = db Max gain = db
Antenna Pointing Guide
Antenna Pointing Guide 1039429-0001 Revision B September 10, 2013 11717 Exploration Lane, Germantown, MD 20876 Phone (301) 428-5500 Fax (301) 428-1868/2830 Copyright 2013 Hughes Network Systems, LLC All
More informationQDV120 Operation and Pointing manual
QDV120 Operation and Pointing manual MPAD1 Plus OP-080316-E1 page 1 Contents Item Description Page 1.0 Health and Safety for Operators and Installation Staff 3 2.0 Transit case Reflector/Mount/BUC/LNB
More informationWEB I/O. Wireless On/Off Control USER MANUAL
Wireless On/Off Control Technical Support: Email: support@encomwireless.com Toll Free: 1 800 617 3487 Worldwide: (403) 230 1122 Fax: (403) 276 9575 Web: www.encomwireless.com Warnings and Precautions Warnings
More informationRADITEK INC. code -g11
code -g11 RM&C Software Remote Monitoring & Control for Desktop Installation and Operation Manual Rev. 17 Sep 2011 TABLE OF CONTENTS CHAPTER 1... 1 GENERAL INFORMATION... 1 1.1 INTRODUCTION... 1 1.2 SYSTEM
More informationWIRES-X Portable Digital Node Function. Instruction Manual
Wide-Coverage Internet Repeater Enhancement System WIRES-X Portable Digital Node Function Instruction Manual Please read this Instruction Manual carefully for appropriate procedure. Preparation Procedure
More informationVersion 9.1 SmartPTT Monitoring
Version 9.1 SmartPTT Monitoring December 2016 Table of Contents Table of Contents 1.1 Introduction 2 1.2 Installation of the SmartPTT software 2 1.3 General SmartPTT Radioserver Configuration 6 1.4 SmartPTT
More informationLinkAlign-60RPT Set-up and Operation Manual
LinkAlign-60RPT Set-up and Operation Manual LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 1 LinkAlign Setup and Operation Proprietary, Nextmove Technologies Page 2 Description of
More informationTX CONTROLLER Model EM-IP Quick Start Guide
TX CONTROLLER Model EM-IP Quick Start Guide 860 boul. de la Chaudière, suite 200 Québec (Qc), Canada, G1X 4B7 Tel.: +1 (418) 877-4249 Fax: +1 (418) 877-4054 E-Mail: gdd@gdd.ca Web site: www.gdd.ca Visit
More informationInstallation Guide. Hiltron Motorized Antenna Mount HMAM
HMAM_Install_A.doc Page 1 of 20 Installation Guide for Hiltron Motorized Antenna Mount HMAM HMAM_Install_A.doc Page 2 of 20 Table of Contents 1 Overview...3 2 Unpacking and Inspection...3 3 Contents of
More informationExternal Source Control
External Source Control X-Series Signal Analyzers Option ESC DEMO GUIDE Introduction External source control for X-Series signal analyzers (Option ESC) allows the Keysight PXA, MXA, EXA, and CXA to control
More informationMDX420 Input Level Field Calibration Procedure AN227 Rev. 1.0
MDX420 Input Level Field Calibration Procedure AN227 Rev. 1.0 Radyne Corporation 3138 E. Elwood St. Phoenix, AZ 85034 (602) 437-9620 Fax: (602) 437-4811 MDX420 Input Level Field Calibration Procedure AN227
More informationSutron SatLink2 Troubleshooting Instructions
Sutron SatLink2 Troubleshooting Instructions A. SatLink2 (SL2) symptoms: Missing or partial data on LRGS (check DIS-MSG for frequency and EIRP; use HDR DCP Message header list. B. Equipment and tools needed:
More informationSatellite Terminal. Installation Guide. Release 2.2 Ref. nr
Satellite Terminal Installation Guide Release 2.2 Ref. nr. 37628 Table of Contents Table of Contents Table of Contents... 2 1 Introduction... 3 1.1 About this Guide... 3 1.2 Material Provided in the Box...
More informationRC3000 Antenna Controller Appendix ASC Integrated ASC Beacon Receiver. Appendix ASC. Integrated ASC Beacon Receiver Option
Revision: 5 December 2012, software version 1.60 Appendix ASC Integrated ASC Beacon Receiver Option This appendix describes the additional functions provided by the RC3000's integrated Atlantic Satellite
More informationMarlink X7 modem tool v2.2 user manual
Marlink X7 modem tool v2.2 user manual Revision History Date: Changes: Changed by: 24.07.2013 Official release of version 2.0 JME 21.08.2013 Renaming to Marlink X5 Modem Tool, small changes to manual JME
More informationidirect infiniti series 3000/5000/7000 Satellite Router and idirect NetModem II Plus
idirect infiniti series 3000/5000/7000 Satellite Router and idirect NetModem II Plus Installation Quick Reference Guide August 12, 2005 Release 6.X CORPORATE HEADQUARTERS 13865 SUNRISE VALLEY DRIVE HERNDON,
More informationField Device Manager Express
Honeywell Process Solutions Field Device Manager Express Software Installation User's Guide EP-FDM-02430X R430 June 2012 Release 430 Honeywell Notices and Trademarks Copyright 2010 by Honeywell International
More informationAPX Mobile and Portable Automated Test and Alignment
APX Mobile and Portable Automated Test and Alignment Software Updates First things first! Be sure to check that you are running the latest software versions for the 8800SX and its applications. Visit the
More informationThese modem profiles has manual configuration of the satellite information and can therefore be altered using the UCLI.
TECHNICAL DOCUMENT Doc no.: 95-136158-G Introduction: This document describes the UCLI (User Command Line Interface) used to manually control the SAILOR 900 VSAT via telnet and get status information.
More informationAppendix BCN. Integrated Beacon Receiver Option
Revision: 1 October 2012, software version 1.00 Appendix BCN Integrated Beacon Receiver Option This appendix describes the additional functions provided by the RC4000's integrated Beacon receiver option.
More information3 GHz Carrier Backhaul Radio. Model: AF-3X. Tel: +44 (0) Fax: +44 (0) LINK GPS MGMT DATA DATA
LINK GPS MGMT DATA DATA MGMT GPS LINK 3 GHz Carrier Backhaul Radio Model: AF-3X LINK GPS MGMT DATA 3 GHz Carrier Backhaul Radio Model: AF-3X LINK GPS MGMT DATA DATA MGMT GPS LINK Introduction Thank you
More informationLinkAlign-360FER Set-up and Operation Manual
LinkAlign-360FER Set-up and Operation Manual Proprietary, Nextmove Technologies Page 1 Proprietary, Nextmove Technologies Page 2 Table of Contents General Notes:... 4 Description of items included with
More information2005 ODU Point & Peak Job Aid
Summary This Job Aid covers: Preparing the Antenna for Pointing and Peaking Point Elevation Set the Skew Point Azimuth Peak Azimuth Peak Elevation Push/Pull Test This Job Aid supports all Technician audiences.
More informationFaculty of Electrical & Electronics Engineering BEE4233 Antenna and Propagation. LAB 1: Introduction to Antenna Measurement
Faculty of Electrical & Electronics Engineering BEE4233 Antenna and Propagation LAB 1: Introduction to Antenna Measurement Mapping CO, PO, Domain, KI : CO2,PO3,P5,CTPS5 CO1: Characterize the fundamentals
More informationAPPENDIX B - MOUNT SPECIFIC DATA For. Patriot 3.8m Mobile Antenna
RC Antenna Controller Appendix B Mount Specific Data 1 APPENDIX B - MOUNT SPECIFIC DATA For Patriot.8m Mobile Antenna REVISION HISTORY 29 December 26, Software Version 1.58 27 October 29, Software Version
More information75cm ODU/SurfBeam 2 Point and Peak Job Aid
Summary This Job Aid covers: 75cm ODU/SurfBeam 2 Point and Peak Job Aid Preparing the Antenna for Pointing and Peaking Configure the SurfBeam 2 Modem and 75cm TRIA Point Elevation Set the Skew Point Azimuth
More informationKaseya 2. User Guide. Version 7.0
Kaseya 2 vpro User Guide Version 7.0 May 30, 2014 Agreement The purchase and use of all Software and Services is subject to the Agreement as defined in Kaseya s Click-Accept EULATOS as updated from time
More informationDataCAD 18 Softlock. Universal Installer. Installation. Evaluation
DataCAD 18 Softlock DataCAD 18 uses a software-based license management option, referred to as a softlock, in lieu of the hardware-based USB license key, or hardlock used by older versions. Each DataCAD
More informationRM600 Carrier Grade E1 Radios
Carrier Grade E1 Radios Quick Start Guide Package Contents ODU 1 IDU 1 Mast/Wall Mounting Kit 1 Outdoor Ethernet Cable (Optional) 1 External Antenna (Optional) 1 Power Supply Cable 1 Quick Start Guide
More informationEOS 80D (W) Wireless Function Instruction Manual ENGLISH INSTRUCTION MANUAL
EOS 80D (W) Wireless Function Instruction Manual ENGLISH INSTRUCTION MANUAL Introduction What You Can Do Using the Wireless Functions This camera s wireless functions let you perform a range of tasks wirelessly,
More informationParadigm. Connect100 Installation Guide
Paradigm GX Connect100 Installation Guide Paradigm GX Safe Use WARNING Radiation Hazard. Transmitter power levels are sufficient to cause blindness or other serious injury to body tissue. Do not power
More informationSETTOPSURVEY, S.L. Bofarull 14, Barcelona (Spain) Phone: (+34) Fax: (+34)
USER MANUAL v.5 Settop Repeater 2 Index SETTOP Repeater... 3 Control Software... 5 SETTINGS: Configuration... 7 RADIO... 8 INTERNET SETUP: Configuration of the internet protocols... 10 CELLULAR MODEM:
More information2009 ODU Point and Peak Job Aid
Summary This Job Aid covers: Preparing the Antenna for Pointing and Peaking Point Elevation Set the Skew Point Azimuth Peak Azimuth Peak Elevation Push/Pull Test This Job Aid supports all Technician audiences.
More informationAW2400iTR USER S MANUAL 2.4 GHz Indoor Wireless Ethernet Radio
USER S MANUAL 2.4 GHz Indoor Wireless Ethernet Radio Industrial-grade, long-range wireless Ethernet systems AvaLAN W I R E L E S S Thank you for your purchase of the AW2400iTR Indoor Wireless Ethernet
More informationetatronix PMA-3 Transmitter Tester Manual
etatronix PMA-3 Transmitter Tester Manual TxTester_Manual_rev1.02.docx 1 Version Version Status Changes Date Responsible 1 Release Initial release 01. Apr. 2015 CW 1.01 Release Updated Figure 4 for better
More informationELECRAFT KX3 EXTENDED VFO TEMPERATURE COMPENSATION PROCEDURE Copyright 2012 Elecraft LLC Rev. A9, November 14, 2012
ELECRAFT KX3 EXTENDED VFO TEMPERATURE COMPENSATION PROCEDURE Copyright 2012 Elecraft LLC Rev. A9, November 14, 2012 Introduction The KX3 standard VFO temperature compensation is entirely adequate for most
More informationHytera. PD41X Patrol Management System. Installation and Configuration Guide
Hytera PD41X Patrol Management System Installation and Configuration Guide Documentation Version: 01 Release Date: 03-2015 Copyright Information Hytera is the trademark or registered trademark of Hytera
More informationGain And Arbitrary Beamwidth Measurement For Identical Test Antennas
Simple Antenna Measurements Using DAMs5.0 Advanced Software DESKTOP ANTENNA TEST SYSTEM Gain And Arbitrary Beamwidth Measurement For Identical Test Antennas This note demonstrates the measurement proceeder
More informationUnit 2: Smiley Basics Student Guide. Derek Dennis
Unit 2: Smiley Basics Student Guide Derek Dennis KENAN FELLOWS PROJECT 2010 Smiley Basics Student Guide 2010 Edition Student: Teacher: Class Period: Unit 2: Smiley Basics Student Guide 1 Table of Contents
More informationKM-4800w. Copy/Scan Operation Manual
KM-4800w Copy/Scan Operation Manual NOTE: This Operation Manual contains information that corresponds to using both the metric and inch versions of these machines. The metric versions of these machines
More informationIG-2500 OPERATIONS GROUND CONTROL Updated Wednesday, October 02, 2002
IG-2500 OPERATIONS GROUND CONTROL Updated Wednesday, October 02, 2002 CONVENTIONS USED IN THIS GUIDE These safety alert symbols are used to alert about hazards or hazardous situations that can result in
More informationQuick Site Testing with the 8800SX
Quick Site Testing with the 8800SX Site Testing with the 8800SX Basic Tests 5 site testing involves several tests to verify site operation. NOTE: This is not intended to be a complete commissioning procedure.
More informationHiSeasNet 2015 Troubleshooting Session
HiSeasNet 2015 Troubleshooting Session November 4th, 2015 RVTEC in Miami Steve Foley Scripps Institution of Oceanography 1 The Big Picture! Note both directions, Tx and Rx, must be intact for the whole
More informationDRC 3500 Versatile Ka-Band Transceiver
DRC 3500 Key Features: Flexible Polarisation: RHCP/ LHCP and cross/co-polar 2 GHz operation by switchable sub-bands Optimised, integrated Feed-chain for highest EIRP and G/T True 5 Watt P1dB at the Feed
More informationWIRES-X Portable Digital Node Function. Instruction Manual
Wide-Coverage Internet Repeater Enhancement System WIRES-X Portable Digital Node Function Instruction Manual Please read this Instruction Manual carefully for appropriate procedure. Preparation Procedure
More informationGNSS Conductor GF. User s Guide. (Document No. SE )
GNSS Conductor GF User s Guide (Document No. ) www.furuno.com IMPORTANT NOTICE No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying
More informationRFID Antenna Measurement
Application Note #0 February 00 Revised: January 0 RFID Antenna Measurement This example demonstrates the basic measurement technique and utilizes most (but not all) of the DAMS Software capabilities.
More informationExercise 4. Angle Tracking Techniques EXERCISE OBJECTIVE
Exercise 4 Angle Tracking Techniques EXERCISE OBJECTIVE When you have completed this exercise, you will be familiar with the principles of the following angle tracking techniques: lobe switching, conical
More informationDataCAD Softlock License Activation and Management
DataCAD Softlock License Activation and Management DataCAD uses a software-based license management technology called a softlock, in lieu of the hardware-based USB key, or hardlock used by older versions.
More informationID Photo Processor. Batch photo processing. User Guide
ID Photo Processor Batch photo processing User Guide 2015 Akond company 197342, Russia, St.-Petersburg, Serdobolskaya, 65a Phone/fax: +7(812)384-6430 Cell: +7(921)757-8319 e-mail: info@akond.net http://www.akond.net
More informationCOMMPAK I/O8. Wireless On/Off Control USER MANUAL
Wireless On/Off control Manual (IO8) V5.0.0 for use with firmware V4.0.0 or higher Email: July 28, 2015 support@encomwireless.com Toll Free: 1-800-617-3487 Worldwide: (403) 230-1122 Fax: (403) 276-9575
More information"Terminal RG-1000" Customer Programming Software. User Guide. August 2016 R4.3
"Terminal RG-1000" Customer Programming Software User Guide August 2016 R4.3 Table of Contents Table of Contents Introduction 2 3 1.1 Software installation 3 1.2 Connecting the RG-1000 GATEWAYs to the
More informationPXIe Contents CALIBRATION PROCEDURE
CALIBRATION PROCEDURE PXIe-5632 This document contains the verification and adjustment procedures for the PXIe-5632 Vector Network Analyzer. Refer to ni.com/calibration for more information about calibration
More informationOmniverse Setup Instructions
Omniverse Setup Instructions Hello Omni customer, Please follow the steps outlined below to get your Omni ready for Omniverse! Let us know if you have questions or issues at any time at support@virtuix.com.
More informationVersion SmartPTT Enterprise. Web Client User Guide
Version 9.3.1 July 2018 Contents Contents 1 Introduction 3 2 SmartPTT Web Client Interface 4 3 Logging in and Changing User 6 4 7 4.1 Making and Receiving Voice Calls 8 4.2 Sending Messages 11 4.3 Finding
More informationISONIC PA AUT Spiral Scan Inspection of Tubular Parts Operating Manual and Inspection Procedure Rev 1.00 Sonotron NDT
ISONIC PA AUT Spiral Scan Inspection of Tubular Parts Operating Manual and Inspection Procedure Rev 1.00 Sonotron NDT General ISONIC PA AUT Spiral Scan Inspection Application was designed on the platform
More informationYCE13. Dealer PC Programming Software Reference Manual. Attention!
YCE13 Dealer PC Programming Software Reference Manual Attention! The YCE13 programing software can only be used with HX380/400 firmware version Ver. 2.00 or later. This software is used to program the
More informationAES 7705i MultiNet Receiver System Initial Installation and Setup Guide
AES 7705i MultiNet Receiver System Initial Installation and Setup Guide AES Corporation 285 Newbury Street. Peabody, Massachusetts 01960-1315 USA Tel: USA (978) 535-7310. Fax: USA (978) 535-7313 Copyright
More informationC-COM Satellite Systems Inc. Page 1 of 39
Page 1 of 39 inetvu Fly-75V & Fly-98G/H/V & Fly-981 User Manual The inetvu brand and logo are registered trademarks of C-COM Satellite Systems, Inc. Copyright 2006 C-COM Satellite Systems, Inc. 1-877-iNetVu6
More informationVersion SmartPTT Enterprise. Installation and Configuration Guide
Version 9.3.1 July 2018 Contents Contents 1 Introduction 4 2 Preliminary Actions 5 2.1 HDD Space Estimation 5 3 Installation of SmartPTT Software 7 4 General SmartPTT Radioserver Configuration 12 5 SmartPTT
More informationKeysight Technologies PNA Microwave Network Analyzers
Keysight Technologies PNA Microwave Network Analyzers Application Note Banded Millimeter-Wave Measurements with the PNA 02 Keysight PNA Microwave Network Analyzers Application Note Table of Contents Introduction...
More informationVerification Test Plan
(Note: the configuration data provided in this test plan is subject to change.) Antenna Verification Testing and scheduling Tel: +1 202 944 6796 Cell phone:+1 202 445 0730 Fax: +1 202 944 7000 Antenna
More informationADI-100 Interrupter. Operator s Manual. 526 S. Seminole Bartlesville, OK /
ADI-100 Interrupter Operator s Manual 526 S. Seminole Bartlesville, OK 74003 918/336-1221 www.sescocp.com ADI - 100 Interrupter FEATURES Clock Accuracy 100% during GPS lock Clock Drift 30 µsec per degree
More informationAntenna and Propagation
Antenna and Propagation This courseware product contains scholarly and technical information and is protected by copyright laws and international treaties. No part of this publication may be reproduced
More informationAirScope Spectrum Analyzer User s Manual
AirScope Spectrum Analyzer Manual Revision 1.0 October 2017 ESTeem Industrial Wireless Solutions Author: Date: Name: Eric P. Marske Title: Product Manager Approved by: Date: Name: Michael Eller Title:
More informationWPE 48N USER MANUAL Version1.1
Version1.1 Security instructions 1. Read this manual carefully. 2. Follow all instructions and warnings. 3. Only use accessories specified by WORK PRO. 4. Follow the safety instructions of your country.
More informationUCP-Config Program Version: 3.28 HG A
Program Description HG 76342-A UCP-Config Program Version: 3.28 HG 76342-A English, Revision 01 Dev. by: C.M. Date: 28.01.2014 Author(s): RAD Götting KG, Celler Str. 5, D-31275 Lehrte - Röddensen (Germany),
More informationUser Configurable POSITION 303 DATA OUTPUT 450 HEADING 910
WinFrog Device Group: Device Name/Model: Device Manufacturer: Device Data String(s) Output to WinFrog: WinFrog Data String(s) Output to Device: WinFrog Data Item(s) and their RAW record: GPS TRACS TDMA
More informationKeysight MOI for MIPI D-PHY Conformance Tests Revision Oct, 2014
Revision 1.10 10-Oct, 2014 Keysight Method of Implementation (MOI) for MIPI D-PHY Conformance Tests Using Keysight E5071C ENA Network Analyzer Option TDR 1 Table of Contents 1. Modification Record... 4
More informationNEXEDGE Type-D Trunking System
NEXEDGE Type-D Trunking System 2015.26.05 Copyright 2014 JVCKENWOOD Corporation. All rights reserved. 1. Type-D Trunking Overview 1. Type-D Trunking System Overview NEXEDGE Type-D Trunking System New affordable
More informationYou can easily print images using the Capture NX print function. Here we will explain the process for printing
Printing - Print Size Request How do you print images to fit on particular paper sizes. Response You can easily print images using the Capture NX print function. Here we will explain the process for printing
More informationUSER S MANUAL ADDENDUM Matched Pair Bridges
USER S MANUAL ADDENDUM Matched Pair Bridges Certain AvaLAN radios are sold as matched pairs, pre-configured as a wireless Ethernet bridge. The manual supplied with the pair does not include information
More informationSolinst Remote Radio Link (RRL Gold) User Guide
Solinst Remote Radio Link (RRL Gold) User Guide Version 1.4.0 March 21, 2016 2016 Solinst Canada Ltd. All rights reserved. Printed in Canada. Solinst and Levelogger are registered trademarks of Solinst
More informationVoIP Paging Amplifier and Elastix Server
VoIP Paging Amplifier and Elastix Server Setup Guide http://www.elastix.org 1.0 Setup Diagram Figure 1-1 is a setup diagram for a single VoIP Paging Amplifier configuration. In this configuration, the
More informationDPM Kit DK-1. Using the DPM Kit
DPM Kit DK-1 Using the DPM Kit To ensure safe usage with a full understanding of this product's performance, please be sure to read through this manual completely. Store this manual in a safe place where
More informationDXXX Series Servo Programming...9 Introduction...9 Connections HSB-9XXX Series Servo Programming...19 Introduction...19 Connections...
DPC-11 Operation Manual Table of Contents Section 1 Introduction...2 Section 2 Installation...4 Software Installation...4 Driver Installastion...7 Section 3 Operation...9 D Series Servo Programming...9
More informationFAQ and Solutions. 02 May TM and copyright Imagicle spa
FAQ and Solutions 02 May 2018 TM and copyright 2010-2018 Imagicle spa Table of Contents FAQ and Solutions...1/11 SkyStone and network security settings...1/11 Upgrade procedure to support Skype 7.32...2/11
More informationAgilent MOI for MIPI D-PHY Conformance Tests Revision 1.00 Dec-1, 2011
Revision 1.00 Dec-1, 2011 Agilent Method of Implementation (MOI) for MIPI D-PHY Conformance Tests Using Agilent E5071C ENA Network Analyzer Option TDR 1 Table of Contents 1. Modification Record... 4 2.
More informationMESA-HPX. Assembly and Installation Manual. w/appendix A for Prodelin Antenna. 901-Manual-MESA-HPX
MESA-HPX Assembly and Installation Manual w/appendix A for Prodelin Antenna 901-Manual-MESA-HPX Rev 30 March 2011 2 INDEX Installation Cautions 4 Installation Pole Height Orientation of the Mount on the
More informationBase Station Commissioning
CHAPTER 7 Base Station Commissioning In This Chapter: Commissioning Overview, page 78 Alarms, page 80 Receiver Sensitivity Test, page 81 Transmit Power Tests, page 87 Network Connection and Ping Test,
More informationORCA-50 Handheld Data Terminal UHF Demo Manual V1.0
ORCA-50 UHF Demo Manual V1.0 ORCA-50 Handheld Data Terminal UHF Demo Manual V1.0 Eximia Srl. www.eximia.it - www.rfidstore.it mario.difloriano@eximia.it 1 Eximia Srl www.eximia.it - www.rfidstore.it Catelogue
More informationINSTALLATION & OPERATION MANUAL
INSTALLATION & OPERATION MANUAL PREFACE This installation & operation manual is intended as an instruction manual for trained person who is in charge of installation, maintenance, repair, etc. Before installation
More informationLD2342 USWM V1.6. LD2342 V1.4 Page 1 of 18
LD2342 USWM V1.6 LD2342 V1.4 Page 1 of 18 GENERAL WARNINGS All Class A and Class B marine Automatic Identification System (AIS) units utilize a satellite based system such as the Global Positioning Satellite
More informationQuick Start Guide for the PULSE PROFILING APPLICATION
Quick Start Guide for the PULSE PROFILING APPLICATION MODEL LB480A Revision: Preliminary 02/05/09 1 1. Introduction This document provides information to install and quickly start using your PowerSensor+.
More informationINSTRUCTION MANUAL IP REMOTE CONTROL SOFTWARE RS-BA1
INSTRUCTION MANUAL IP REMOTE CONTROL SOFTWARE RS-BA FOREWORD Thank you for purchasing the RS-BA. The RS-BA is designed to remotely control an Icom radio through a network. This instruction manual contains
More informationOUTDOOR SOUND MODULE/TRANSMITTER MODEL: THE BANDIT
Page 1 of 16 FCC PART 15, SUBPART B and C TEST REPORT for OUTDOOR SOUND MODULE/TRANSMITTER MODEL: THE BANDIT Prepared for MINASKA OUTDOORS 6517 PLATTE AVENUE LINCOLN, NEBRASKA 68507 Prepared by: KYLE FUJIMOTO
More informationAbout the DSR Dropout, Surge, Ripple Simulator and AC/DC Voltage Source
About the DSR 100-15 Dropout, Surge, Ripple Simulator and AC/DC Voltage Source Congratulations on your purchase of a DSR 100-15 AE Techron dropout, surge, ripple simulator and AC/DC voltage source. The
More informationMultiSim and Analog Discovery 2 Manual
MultiSim and Analog Discovery 2 Manual 1 MultiSim 1.1 Running Windows Programs Using Mac Obtain free Microsoft Windows from: http://software.tamu.edu Set up a Windows partition on your Mac: https://support.apple.com/en-us/ht204009
More informationA Walk Through the MSA Software Vector Network Analyzer Transmission Mode 12/18/09
A Walk Through the MSA Software Vector Network Analyzer Transmission Mode 12/18/09 This document is intended to familiarize you with the basic features of the MSA and its software, operating as a Vector
More informationGuardian and DL3282 Modem Interface Technical Service Application Note
Guardian and DL3282 Modem Interface Technical Service Application Note OVERVIEW The following document is designed to provide information for the implementation of the Guardian Wireless Modem/Analog Radio
More informationFire CR Calibration Guide
1 Fire CR Calibration Guide This reference guide will guide you through the steps to complete the calibration for the Fire CR.. Getting Started: 1. Click on the Opal Icon on the Desktop. Figure 1 2. Once
More informationThe ideal K-12 science microscope solution. User Guide. for use with the Nova5000
The ideal K-12 science microscope solution User Guide for use with the Nova5000 NovaScope User Guide Information in this document is subject to change without notice. 2009 Fourier Systems Ltd. All rights
More informationVersion 9.1 SmartPTT Enterprise. Installation & Configuration Guide
Version 9.1 SmartPTT Enterprise December 2016 Table of Contents Table of Contents 1.1 Introduction 3 1.2 Installation of the SmartPTT software 3 1.3 General SmartPTT Radioserver Configuration 7 1.4 SmartPTT
More informationLINK GPS MGMT DATA. 4 GHz Licensed Backhaul Radio DATA MGMT GPS. Model: AF-4X LINK
LINK GPS MGMT DATA DATA MGMT GPS LINK 4 GHz Licensed Backhaul Radio Model: AF-4X 4 GHz Licensed Backhaul Radio Model: AF-4X LINK GPS MGMT DATA DATA MGMT GPS LINK Introduction Thank you for purchasing the
More information8800SX DMR Repeater Test Option 06
8800SX DMR Repeater Test Option 06 DMR Repeater Test Option The DMR Repeater test option allows testing of a DMR Repeater that is in conventional DMR Mode. Trunking or analog configurations are not supported.
More informationF8101ALE User s Guide
RadCommSoft, LLC F8101ALE User s Guide Aug 2017 1 F8101ALE User s Guide RadCommSoft, LLC presents F8101ALE F8101ALE is remote control software for the ICOM IC-F8101E, and includes a modem controller for
More informationFCC ID: A3LSLS-BD106Q. Report No.: HCT-RF-1801-FC003. Plot Data for Output Port 2_QPSK 9 khz ~ 150 khz Middle channel 150 khz ~ 30 MHz Low channel
Plot Data for Output Port 2_QPSK 9 khz ~ 150 khz Middle channel 150 khz ~ 30 MHz Low channel 30 MHz ~ 1 GHz Middle channel 1 GHz ~ 2.491 GHz Low channel 2.695 GHz ~ 12.75 GHz High channel 12.75 GHz ~ 26.5
More informationAgilent MOI for MIPI M-PHY Conformance Tests Revision Mar 2014
Revision 1.10 20 Mar 2014 Agilent Method of Implementation (MOI) for MIPI M-PHY Conformance Tests Using Agilent E5071C ENA Network Analyzer Option TDR 1 Table of Contents 1. Modification Record... 4 2.
More informationANTENNA SYSTEMS. 1.8m Offset Rx & TxRx Antenna INSTALLATION & ASSEMBLY INSTRUCTIONS
ANTENNA SYSTEMS.m Offset Rx & TxRx Antenna INSTALLATION & ASSEMBLY INSTRUCTIONS LIMITED TWELVE () MONTH WARRANTY This PATRIOT ANTENNA equipment is warranted to be free from defects in material and workmanship
More informationDAMs Universal Link Commander
Application Note #0428 May 2012 Revised: DAMs Universal Link Commander Application Note The Link Commander enables link analysis with or without DAMs measured data. It also enables range and Bit Error
More information