1 Your Simple, Accurate and Economical Temperature Controller Compact temperature controller (DIN 8 ) that can support pattern control Additions to KT series KT Temperature Controller Broad lineup of temperature controllers allow you to satisfy application and space requirements. KT Series [8 98.5mm] KT Series [8 8 95mm] KT7 Series [.5 75 mm] KTH KT8 Series [ mm] KT9 Series [ mm] KTH/B Series [8 8 5mm] KTB Compliance with RoHS Directive FEATURES. Multi-input Versatile thermocouple, RTD, DC voltage and DC current input for temperature detecting sensors. Simple operation enables highly accurate temperature control All required operations can be enabled by the front keys and highly accurate PID control mode ensures an input span of ±.%.. DIN Rail mounting types are aligned taking global market demand into consideration The KT7 series is equipped with DIN rail mounting complying to DIN standards. Furthermore, because its control panel is compact, the KT7 saves space.. Nine step pattern control possible. For KT series, despite DIN 8 size, selection is possible of control with fixed set point and nine step pattern control. 5. Meets market demands for costeffectiveness The KT series offers both economy and high performance.. The KT series complies with UL, CSA standards and CE marking. 7. Improved visibility and ease of operation More compact than before The KTH/KTB series features the largest PV digit size in the industry. Visibility is improved with an -segment display. Connectable to a PC, it offers a full range of control and communication functions. 8. Communication specification uses RS85 (Modbus protocol) (Sample System Configuration) FPΣ Programmable Controller (Panasonic Electric Works) RS-85 Up to units can be connected *In the configuration above, the FPΣ requires a communication cassette (FPG-COM). *Modbus is a communication protocol developed for PLCs by Modicon Inc. 9. panasonic-electric-works.net/ac Panasonic Electric Works Co., Ltd.

2 KT (AKT,,7,8,9,H,B) PRODUCT TYPES. KT Series Base model AKT Power supply Sensor input Control Alarm Heating/ cooling control Heater burnout alarm * When heating/cooling is selected, alarm cannot be used. When the communication function is selected, alarm cannot be used. Communication function mm Description to V AC Must be V AC/DC specified Multi-input (Thermocouple, RTD, DC current and DC voltage) Relay contact a A 5V AC Non-contact voltage (for SSR drive) Current Blank Blank Must be specified When both heating/cooling and communication functions are not added: Relay contact (alarm ): Can be used Open collector (alarm ): Can be used When only heating/cooling function is added: Relay contact (alarm ): Cannot be used Open collector (alarm ): Can be used When only communication function is added: Relay contact (alarm ): Can be used Open collector (alarm ): Cannot be used When both heating/cooling and communication functions are added: Relay contact (alarm ): Cannot be used Open collector (alarm ): Cannot be used Part No. (Ex) Part No. when the optional functions (of Heating/Cooling control: relay contact + Communications function) is added on to the basic model are as follows; Part No.: AKT Options Product name Part No. Shunt resistor (for Current input) AKT8 Terminal cover AKT8 Note: When Current input is specified, a shunt resistor (sold separately) is required.. KT Series AKT mm to V AC V AC/DC Multi-input (Thermocouple, RTD, DC Voltage and DC Current) Relay contact a A 5V AC Non-contact voltage (for SSR drive) Current Relay contact a (Alarm ) Relay contact a (Alarm ) Not available SSR.A 5V AC (Heating/Cooling control not supported when alarm points are selected) Not available 5A (Heater burn-out alarm not supported when control is current A (Heater burn-out alarm not supported when control is current A (Heater burn-out alarm not supported when control is current 5A (Heater burn-out alarm not supported when control is current Not available Available Notes:. CT or CT for current detection is provided as an accessory when heater burn-out alarm function is added.. Event will be shared if you choose alarm and the heater burnout alarm. Part No. (Ex) Part No. when the optional functions (of Heating/Cooling control: SSR + Communications function) is added on to the basic model are as follows; Part No.: AKT Options Product name Part No. Shunt resistor (for Current input) AKT8 Terminal cover AKT8 Note: When Current input is specified, a shunt resistor (sold separately) is required. Base model Power supply Sensor input Control Alarm Heating/ cooling control Heater burnout alarm Communications function Description

3 . KT8 Series Base Power model supply AKT8 Notes:. CT or CT for current detection is provided as an accessory when heater burn-out alarm function is added.. If a communication function is added, second main setup is not possible KT (AKT,,7,8,9,H,B) Part No. (Ex) Part No. when the optional functions (of Alarm ; Alarm + Heating/Cooling control: Current ) are added on to the basic model are as follows; Part No.: AKT8 Options Product name Part No. Shunt resistor (for Current input) AKT8 Terminal cover AKT88 Note: When Current input is specified, a shunt resistor (sold separately) is required.. KT9 Series Base Power model supply AKT9 Sensor input Control Alarm Heating/cooling control Heater burnout alarm Communications function Description mm to V AC V AC/DC Multi-input (Thermocouple, RTD, DC Voltage and DC Current) Relay contact ab A 5V AC Non-contact voltage (for SSR drive) Current Relay contact a (Alarm ) Relay contact a (Alarm ) Not available Relay contact a Non-contact voltage (for SSR drive) Current Not available Sensor input Control Alarm Heating/cooling control Heater burnout alarm 5A (Heater burn-out alarm not supported when control is current A (Heater burn-out alarm not supported when control is current A (Heater burn-out alarm not supported when control is current 5A (Heater burn-out alarm not supported when control is current Not available Available Communications function Description mm to V AC V AC/DC Multi-input (Thermocouple, RTD, DC Voltage and DC Current) Relay contact ab A 5V AC Non-contact voltage (for SSR drive) Current Relay contact a (Alarm ) Relay contact a (Alarm ) Not available Relay contact a Non-contact voltage (for SSR drive) Current Not available 5A (Heater burn-out alarm not supported when control is current A (Heater burn-out alarm not supported when control is current A (Heater burn-out alarm not supported when control is current 5A (Heater burn-out alarm not supported when control is current Not available Available Notes:. CT or CT for current detection is provided as an accessory when heater burn-out alarm function is added.. If a communication function is added, second main setup is not possible Part No. (Ex) Part No. when the optional functions (of Alarm ; Alarm + Heating/Cooling control: Non-contact voltage ) are added on to the basic model are as follows; Part No.: AKT9 Options Product name Part No. Shunt resistor (for Current input) AKT8 Terminal cover AKT98 Note: When Current input is specified, a shunt resistor (sold separately) is required.

4 KT (AKT,,7,8,9,H,B) 5. KT7 Series Base model AKT7 Power supply Sensor input Control Alarm Heating/ cooling control Heater burnout alarm Communications function Note: CT or CT for current detection is provided as an accessory when heater burn-out alarm function is added. Description.5 75 mm to V AC V AC/DC Multi-input (Thermocouple, RTD, DC Voltage and DC Current) Relay contact a A 5V AC Non-contact voltage (for SSR drive) Current Open collector (Alarm ) Not available (without Heating/Cooling function) Not available 5A (not available for the Current type) Open collector A (not available for the Current type) Open collector A (not available for the Current type) Open collector 5A (not available for the Current type) Open collector Not available Available Part No. (Ex) Part No. when the optional function (of Heater burnout alarm: A) is added on to the base model are as follows; Part No.: AKT7 Options Product name Part No. Shunt resistor (for Current input) AKT8 Note: When Current input is specified, a shunt resistor (sold separately) is required.. KTH Series Base model Power supply Sensor input Control Alarm Heating/ cooling control Heater burnout alarm Communications function Description AKTH to V AC V AC/DC Multi-input (Thermocouple, RTD, DC Voltage and DC Current) Relay contact Non-contact voltage (for SSR drive) DC current Heater burn-out alarm not possible. point (a) points (a + a) Heating/cooling control not possible. Not available Relay contact Heater burn-out alarm not possible. Non-contact voltage (for SSR drive) Heater burn-out alarm not possible. Not available or Single phase A (Heater burn-out alarm not supported when control is DC or Single phase 5A (Heater burn-out alarm not supported when control is DC or 5 Three phase A (Heater burn-out alarm not supported when control is DC or Three phase 5A (Heater burn-out alarm not supported when control is DC Blank Not available Serial communication RS-85 Contact input Notes:. CT or CT for current transformer is provided as an accessory when heater burn-out alarm function is added.. Under some conditions, option functions (shaded items) may not be available; please check the Descriptions of the above table for non-functioning circumstances. Part No. (Ex) Part No. when the optional functions (Heating/Cooling control + communication function) are added on to the basic model are as follows; Part No.: AKTH Options Product name Part No. Shunt resistor (for Current input) AKT8 Terminal cover AKTH8 Tool cable AKTH8 Setting software Product name Description Remark KT Monitor Editing of all types of data, File saving Monitoring of readings, Saving of log files Note: Please download user manual from the company website. Available for download at no charge from company website.

5 KT (AKT,,7,8,9,H,B) 7. KTB Series Base model Power supply Sensor input Control Alarm Heating/cooling control Heater burnout alarm Communications function Model No. (Relay contact) ( point) ( points) Blank (Not available) (Serial communication) Blank (Not available) (Serial communication) AKTB AKTB AKTB AKTB AKTB ( to V AC) (Multi-input) (Non-contact voltage) ( point) ( points) (Not available) (Not available) Blank (Not available) (Serial communication) Blank (Not available) (Serial communication) AKTB AKTB AKTB AKTB (DC current) ( point) ( points) Blank (Not available) (Serial communication) Blank (Not available) (Serial communication) AKTB AKTB AKTB AKTB *Please inquire if you need specifications not included in the model numbers above. *Use RS85 for serial communication. Example Model No.: AKTB Specifications: Power supply to V AC, Heating/cooling control: Not available, Sensor input: Multi-input, Heater burnout alarm: Not available, Control : Relay contact, Communications function: Not available, Alarm : point Options (Common for KTH and KTB) Product name Model No. Shunt resistor (for Current input) AKT8 Terminal cover AKTH8 Tool cable AKTH8 5

6 KT (AKT,,7,8,9,H,B) RATING & SPECIFICATIONS Display Specifications KT KT KT8 KT9 KT7 KTH/B Size (W H D) mm mm mm mm.5 75 mm 8 8 mm Supply voltage (Must be specified) to V AC V AC/DC Frequency 5/Hz Power consumption Approx. 5VA Approx. 8VA Approx. VA Approx. 8VA Input type Input range to 7 C ( to 5 F) K. to. C 99.9 to. C ( 99.9 to 75. F) ( to 75. F) J to C ( to 8 F) R to 7 C ( to F) S to 7 C ( to F) Thermocouple B to 8 C ( to F) E to 8 C ( to 5 F) T 99.9 to. C ( 99.9 to 75. F). to. C ( to 75. F) N to C ( to F) PL-II to 9 C ( to 5 F) C (W/Re5-) to 5 C ( to F) to 85 C ( to 5 F) Pt. to 85. C 99.9 to 85. C ( 99.9 to F) (. to 5. F) RTD to 5 C ( to 9 F) JPt. to 5. C 99.9 to 5. C ( 99.9 to 9. F) (. to 9. F) to ma DC Current to ma DC 999 to 9999, 99.9 to to V DC 9.99 to 99.99,.999 to DC to to V DC Voltage Scaling and change to the decimal point position is possible for DC current and DC voltage input. to 5V DC DC current input is supported with an externally mounted 5Ω shunt resistor (sold separately). to 5V DC Thermocouple K, J, R, S, B, E, T, N, PL-II, C (W/Re5-) External resistor: Max. Ω (max. Ω external resistor for B input) RTD Pt, JPtΩ -conductor system (Allowable input conductor resistance for each conductor: max. Ω) DC to ma DC Input impedance: 5Ω (Connect 5Ω shunt resistor between input terminals.) current to ma DC Allowable input current: max. 5 ma (when 5Ω shunt resistor is used) to V DC Input impedance: min. MΩ, Allowable input voltage: max 5 V, Allowable signal source resistance: max. kω Multi-input DC voltage Control (Must be specified) Alarm (EVT) Relay contact (Contact material: Ag alloy) Alarm (EVT) Control mode Target temperature setting Program control function to 5V DC to 5V DC Input impedance: min. kω, Allowable input voltage: max 5 V, Allowable signal source resistance: max. Ω to V DC Relay contact (contact a a ab a a material: silver alloy) A 5V AC (Resistive load), A 5V AC (Inductive load cosφ=.), Electric life:, times V DC ±5%, Non-contact DC voltage + V DC, Max. load current: ma (Short-circuit protected) Max. load current: ma (Shortcircuit protected) DC current to madc Load resistance: Max. 55Ω Relay contact a Relay contact a: A 5V AC Open collector, A 5VAC (Resistive load), Relay contact a A 5VAC (Resistive load) Control capacity: (Resistive load) a A 5V AC Electric life:, times V DC.A Electric life: (Inductive load (Max.), times cosφ=.) Thermocouple Accuracy RTD DC current and DC voltage Sampling period Open collector Same as The same as the one of Alarm None.A V DC Alarm Actions mentioned below can be selected by key operation. [Default PID] PID (with auto-tuning function), PI, PD (with manual reset function), P (with manual reset function), ON/OFF action Primary setting/ Primary setting/ secondary setting/ secondary setting Primary setting/secondary setting third setting/fourth (switched by (switched by external terminal) setting (switched external terminal) by external terminal) pattern, 9 step setting is possible (However, make function selection setting of either control with fixed set point or program control.) Within ±.% ± digit of each input span or within ± C ( F) whichever is greater However, R and S input; Within ± C ( F) in the range of to C ( to F) B input to C ( to F): Accuracy is not guaranteed. K, J, T, E, and N input less than C ( F): Within ±.% ± digit of input span Within ±.% ± digit of each input span or ± C ( F) whichever is greater Within ±.% ± digit of each input span 5ms

7 KT (AKT,,7,8,9,H,B) Display Hysteresis (ON/OFF) Proportional band Integral time Derivative time Proportional cycle Allowable voltage fluctuation Insulated resistance Breakdown voltage Specifications KT KT KT8 KT9 KT7 KTH/B Thermocouple & RTD:. to. C (.8 to F) DC current and DC voltage: to (The decimal point place follows the selection) For sensor input range and DC current, DC voltage. to.%.5kv AC for min between input terminal and power terminal, & between terminal and power terminal Thermocouple: to C ( to F) RTD:. to C (. to F) DC current and DC voltage:. to.% For sensor input range and DC current, DC voltage. to.% to seconds to seconds to seconds When to V AC; 85 to V AC When V AC/DC; to 8V AC/DC 5V DC MΩ or greater.5kv AC for min between input terminal and ground terminal, between input terminal and power terminal between power terminal and ground terminal between terminal and ground terminal, & between terminal and power terminal to C ( to 8 F) The decimal point input:. to C ( to 8 F) DC current and DC voltage:. to.%.5kv AC for min between input terminal and power terminal, & between terminal and power terminal Malfunction vibration to 55 Hz (.5 mm) to each direction (ms sweep) for min. to 55 Hz ( cycle/min.) single amplitude.5 mm ( min. on axes) Breakdown vibration to 55 Hz (.75 mm) to each direction (ms sweep) for min. to 55 Hz ( cycle/min.) single amplitude.75 mm ( hour on axes) Malfunction shock X, Y & Z each direction for 5 times 98m/s (G) Breakdown shock Same as above, but 9m/s (G) Ambient temperature to 5 C Ambient humidity 5 to 85%RH (No condensation) Mass Approx. g Approx. g Approx. g Approx. 7g Approx. 5g Approx. g IP (applicable only Waterproof IP (applicable only to the front panel subject to rubber gasket employed) None to the front panel subject to rubber gasket employed) Display character height PV: 8.7mm, PV:.mm PV:.mm PV: 8mm PV: 7.mm PV: mm SV: 8.7mm (PV/SV SV: 8.8mm SV:.mm SV:.mm SV: 7.mm SV: mm switching display) Options Heating/Cooling control (Relay contact material: silver alloy) Heater burn-out alarm (Relay contact material: silver alloy) Communication function Relay contact: a A 5V DC (Resistive load) Non contact relay.a 5V AC (Resistive load) Relay contact: a 5V AC A (Resistive load), 5V AC A (Inductive load cosø=.), Electric life:, times Non-contact voltage: + V DC Max. ma (Short-circuit protected) DC current: to ma DC Load resistance: Max. 55Ω Heater rated current must be selected from 5A, A, A and 5A. Setting accuracy: Within 5% of heater rated current Relay contact a 5V AC A (Resistive load), Electric life:, times RS-85/Modbus Protocol (Modbus is a communication protocol developed for PLCs by Modicon Inc.) Communication speed: /8/9/9bps None Open collector, Control capacity: V DC.A (Max.) Relay contact: Control capacity a: A 5V AC (Resistive load), Electric life:, times Non-contact voltage: V DC±5% Max. ma (Short-circuit protected) Specify either singlephase A, singlephase 5 A, -phase A, or -phase 5 A for rated heater current. Setting accuracy: within ±5% of rated heater current Relay contact a: A 5V AC (Resistive load), Electric life:, times Tool port Communication interface C-MOS level Cannot be used at the same time as serial communication (option). *This port can only be used with the tool cable (AKTH8). Mounting frame Included with unit Not available Included with unit Accessories Terminal cover Sold separately Not available Not available Rubber gasket Not available Included with unit 7

8 KT (AKT,,7,8,9,H,B) COMMUNICATION FUNCTION OVERVIEW Item Specification KT,, 8, 9, 7 KTH/B Communication type Half-duplex Communication speed Select, 8, 9, or 9 bps using key operation. Synchronization type Asynchronous Protocol Modbus Modbus RTU, Modbus ASCII, MEWTOCOL (Slave) Coding ASCII Binary/ASCII Error correcting Command re-send Error detection Parity check, check sum Data structure Start bit:, Data bit: 7, Parity: Even parity, Stop bit: Interface EIA RS85 compliant No. of nodes Maximum cable length, m (cable resistance must be within 5Ω) Note: That main setting No. will not be possible on the KT8 and KT9 when the communications functions is added. PARTS AND FUNCTIONS. KT series PV/SV display (red): Indicates the input value and setting value. During setting mode, characters and setting value of the setting item are indicated in turn. MEMO/STEP display (green): Indicates memory number during fixed value control. Indicates step number during program control. PV indicator (red): Lights up when the input value (PV) is indicated. SV indicator (green): Lights up when main setting value (SV) is indicated. 5 AT indicator (yellow): T/R indicator (yellow): Flashes during AT (auto-tuning). Flashes during serial communication (Lit while sending data, Unlit while receiving data) 7 OUT indicator (green): Lights up when control or OUT (Heating side, option Heating/Cooling control) is ON. (For DC current type, it flashes corresponding to the manipulated variable in a.5 second cycle) 8 EV indicator (red): Lights up when Event or OUT (Cooling side, option Heating/Cooling control) is ON. 9 EV indicator (red): Lights up when Event is ON. Increase key ( ): Increases the numeric value. Decrease key ( ): Decreases the numeric value. Mode key ( MODE ): Selects the setting mode or registers the setting value. (By pressing the Mode key, the setting value or selected value can be registered) OUT OUT/OFF key ( ): The control OUT/OFF or program control RUN/STOP can be switched. OFF 8

9 . KT series. KT8 series KT (AKT,,7,8,9,H,B) 5 PV display Indicates PV (process variable). SV display Indicates SV (setting value). Increase key Increases numerical value. Decrease key Decreases numerical value. 5 Mode key Switches the setting mode. OUT/OFF key Control is turned on or off when control is ON. 5. KT9 series 5. KT7 series 5 5 Note: Color selection is the same for each size.. KTH/B series (Bottom side) Action indicators (backlight: orange) F C... Lights respectively when temperature unit F/ C is selected. T/R... Lights during Serial communication (option) TX. AT... Flashes during auto-tuning or auto-reset OUT... Lights when control is ON or Heating (option) is ON. For DC current type, it flashes corresponding to the manipulated variable in.5 second cycles. OUT... Lights when Cooling (option) is ON. EVT... Lights when Alarm is ON. EVT... Lights when Alarm (option) is ON or Heater burnout alarm (option) is ON. LOCK... Lights when Lock, Lock or Lock is selected. MEMO display... Indicates the set value memory number (backlight: green). PV display... Indicates the PV (process variable) (backlight: red/orange/green). SV display... Indicates the SV (set value) (backlight: green). 5 Mode key... Selects the setting mode, and registers the set value. OUT/OFF key... The control ON/OFF or Auto/Manual control can be switched. 7 Increase key... Increases the numeric value. 8 Decrease key... Decreases the numeric value. 9 Tool connector... By connecting the tool cable, the following operations can be conducted from the external computer using the exclusive tool software. - Reading and setting of SV, PID and various set values from external computer - Reading of PV and action status - Function change 9

10 SV SV OUT OUT AT TX/RX OUT HB A A/LA SV SV MODE OUT OUT OFF HB AT A TX/RX A/LA OUT EV EV KT (AKT,,7,8,9,H,B) DIMENSIONS (unit: mm inch) Tolerance: ± ±.9. KT series External dimension M M.8 Panel cutout Rubber packing Mounting frame.5.7. MEMO/STEP PV SV AT T/R MODE OUT OFF KT Note: The communications terminal is the screw terminal on the back of the unit.. KT series External dimension Panel cutout Rubber gasket Screw type mounting M M PV OUT OUT SV A EVT SV SV TX/RX AT OUT MODE OFF KT n n Lateral close mounting n: Number of units mounted Note: The communications terminal is the screw terminal on the back of the unit.. KT8 series External dimension Panel cutout Rubber gasket Screw type mounting M M PV SV n n Lateral close mounting n: Number of units mounted KT Note: The communications terminal is the screw terminal on the back of the unit.. KT9 series External dimension Rubber gasket Screw type mounting M M.8 Panel cutout 5.8 PV SV n n Lateral close mounting n: Number of units mounted MODE OUT OFF KT Note: The communications terminal is the screw terminal on the back of the unit.

11 5. KT7 series External dimension KT (AKT,,7,8,9,H,B) M M.8 OUT EVT T/R AT PV SV MODE KT M M Note: The communications terminal is the modular jack on the bottom of the unit.. KTH/B series External dimensions Panel cutout Lateral close mounting.5.59 Rubber gasket Mounting frame Terminal cover (Sold separately) M screw n 8 n n: Number of units mounted Notes: If lateral close mounting is used for the controller, IP specification (Dust-proof/Drip-proof) may be compromised, and all warranties will be invalidated.

12 KT (AKT,,7,8,9,H,B) INSTALLATION. KT series Please install vertically in order to satisfy the IP specification for dust and splash proofing. The possible control panel plate thickness for installation is between to mm. () Insert the unit from the front of the control panel. () Insert the mounting frame until that the edges () make contact with the panel. () Tighten the clamp screw and then turn it / of a turn after the edge of the screw reaches the panel.. KT, 7, 8, 9 series Panel Mounting Mountable panel thickness: Within to 5mm.9 to.59inch Insert a controller from the front side of the panel. Attach the mounting brackets by the holes at the top and bottom of the case and secure the controller in place with the screws. DIN rail mounting (KT7) ) Hook of the KT7 on the upper side of the DIN rail. ) Making the part of the KT7 as a support, fit the lower part of the KT7 to the DIN rail. KT7 will be completely fixed to the DIN rail with a Click sound. Recommended DIN rail: Part No. ATA8 Recommended fastening plate: Part No. ATA8 DIN rail pv av G/T EVT T/B AT MODE G/T pv av KT7 EVT T/B AT Fastening plate Notice As the case is made of resin, do not use excessive force while screwing in the mounting bracket. The torque is approximately.n m MODE KTH/B series Please install vertically in order to satisfy the IP specification for dust and splash proofing. The possible control panel plate thickness for installation is between to 5 mm. ) Insert the unit from the front of the control panel. ) Push the installation frame fully into contact with the panel and tighten the screws (screw torque from.5 N m to.n m). Rubber gasket

13 OPTION. Shunt resistor AKT8 (for KT,, 8, 9, H and B) AKT8 (for KT7) KT (AKT,,7,8,9,H,B) ±. ±.9 7 ±.9 ±.. Terminal cover AKT8 (for KT) AKT8 (for KT) AKT88 (for KT8) AKT98 (for KT9) AKTH8 (for KTH/B) = = = = >PC< Note: pcs of terminal cover of AKT88 can be used as an AKT98 cover.. Current transformer (CT) External dimension ) CT (for 5, and A) ) CT (for 5A) 5.8 dia..8 dia. l 5.59 k l.8 k K L dia. -.8 dia. dia..7 dia M Note: CT or CT for current detection is provided as an accessory when heater burn-out alarm function is added.. Tool cable AKTH8 n.5 Plug -Pole type ± ± ± 78.7±.575 USB Plug

14 KT (AKT,,7,8,9,H,B) EXTERNAL CONNECTION DIAGRAM. KT series A B 7 8 A 5V AC TC DC EV/OUT NO B RTD 9 RS-85 YA ( ) YA (+) D EV A 5V AC NO RELAY V/A OUT to V AC POWER SUPPLY V AC/DC POWER SUPPLY TC: Input terminal for thermo couple. RTD: Input terminal for the resistance temperature sensor. DC: Input terminal for DC current or DC voltage. For DC current input, connect a separately sold receipt resistor (5Ω) between the input terminals. OUT: Output terminal for the control or heating [option: heating/cooling control]. POWER SUPPLY: Power supply terminal. EV/OUT: Output terminal for event or cooling [option: heating/cooling control]. EV: Output terminal for event. DI: Input terminal for DI input. (There are three types of D input, the SV/SV external switching function, the OUT/OFF (RUN/STOP) switching function, and timer function.) RS-85: Communication terminal for serial communication. (EV, is alarm ) 5 5 SG.A V DC KT. KT series POWER SUPPLY V AC/DC POWER SUPPLY to V AC CT NO OUT POWER SUPPLY: Power supply OUT: Control (heat ) OUT: Control (cooling ) RELAY: Relay contact V/A: DC voltage /direct current V: Contactless relay A: Alarm EVT: Event (A and heater cutoff alarm ) CT: CT input TC: Thermocouple RTD: Resistance temperature detection DC: Direct current or DC voltage RS-85: Serial communications S EVT.A 5V AC A A 5V AC YA ( ) A 5V AC OUT RELAY RS-85 9 NO YB (+) 5 5 NO SG KT TC 7 8 V/A A B B RTD DC. KT8 and KT9 series POWER SUPPLY V AC/DC GND Note: That main setting No. will not be possible on the KT8 and KT9 when the communications functions is added. YA( ) POWER SUPPLY to V AC NO A/(HB) RS-85 5V AC YB(+) OUT NC SV 5 5 RELAY V/A NO CT A 5V AC 7 7 SG A NO A 8 A 8 OUT/HB 5V AC 9 9 RELAY B NO TC DC V/A B A RTD 5V AC KT8/KT9 POWER SUPPLY: Power supply OUT: Control OUT: Control (cooling ) RELAY: Relay contact V/A: DC voltage /direct current A: Alarm A: Alarm HB: Heater cutoff alarm SV: Second main setup CT: CT input TC: Thermocouple RTD: Resistance temperature detection DC: Direct current or DC voltage RS-85: Serial communications. KT7 series POWER SUPPLY V AC/DC POWER SUPPLY to V AC OUT V/A RELAY A 5V AC KT7.A V DC TC RTD A B B EVT No. DC No. RS-85 No. SG No. No. NC No. No. YB(+) No. YA( ) CT No.5 NC No. SG POWER SUPPLY: Power supply OUT: Control RELAY: Relay contact V/A: DC voltage /direct current EVT: Event [Alarm, loop fault alarm or heater cutoff alarm (optional)] TC: Thermocouple RTD: Resistance temperature detection DC: Direct current or DC voltage RS-85: Serial communications CT: CT input 5. KTH/B series POWER SUPPLY... Power supply EVT... Alarm EVT... Alarm (option) or heater burn-out Alarm (option) OUT... Control or heating (option) OUT... Cooling (option) TC... Thermocouple input RTD... Resistance temperature detection input DC... Direct current input (DCA) or DC voltage input (DCV) (For DC voltage input, + side terminal number differs depending on the voltage. Also, DC current input, connect s shunt resistor between No. and terminal.) CT... Current transformer input (option: Single, three phase) CT... Current transformer input (option: Three-phase) DI... Contact input (option) RS Serial communication RS-85 (option)

15 KT (AKT,,7,8,9,H,B) Communication Function Connection Diagram (PLC Connection Diagram). KT,, 8 and 9 series. KT7 series PLC ( ) (+) RS-85 KT YA ( ) YB (+) COM KT YA ( ) YB (+) 5 COM KT8, 9 YA ( ) YB (+) 7 COM PLC ( ) (+) No. KT7 No. No. Shielded cable KT YA ( ) YB (+) COM KT YA ( ) YB (+) 5 COM KT8, 9 YA ( ) YB (+) 7 COM Communicatin cable Terminal to YB (+) Terminal to YA ( ) Notes:. Terminating Resistors (Terminators) The KT series has a built-in pull-up resistor or pull-down resistor, which serves as the terminating resistor. For this reason, do not connect the terminating resistor on the communication line.. Please use a RJ- polarized type modular connector. Please use a cable that is suitable for a modular connector.. KTH/B series PLC ( ) (+) Shielded cable RS-85 KTH YA ( ) 7 YB (+) 8 COM KTH YA ( ) 7 YB (+) 8 COM Notes:. To prevent current flow along shield sections, ground one end of the shield line. (If both ends of the shield section are grounded, a closed circuit with the earth will form and electricity flowing through the shield line will cause increased susceptibility to noise.). Terminating Resistors (Terminators) The KTH series has a built-in pull-up resistor or pull-down resistor. For this reason, do not connect the terminating resistor on the communication line. NOTICE ON OPERATION. NOTICE ON SITE SELECTION This instrument is intended to be used in the following environment (IEC-) Overvoltage category II, Pollution degree Mount the controller in a place with: ) A minimum of dust, and an absence of corrosive gases ) No flammable, explosive gases ) Few mechanical vibrations or shocks ) No exposure to direct sunlight, an ambient temperature of to 5 C ( to F) that does not change rapidly (When installing inside a panel, make particular allowance for heat dissipation. Avoid installation in situations such as above equipment that generates heat.) 5) Locations in which temperature rapidly changes may cause condensation. ) Locations or atmospheres in which gasoline, thinners, alcohol, or other organic solvents are present, or in which ammonia, sodium hydroxide, or other strong alkaline substances may adhere. 7) Locations susceptible to direct impact or the transmission of vibrations, or where splashing with water is possible. 8) In the proximity of equipment in which large switching surges occur or near high-voltage cables, high-voltage equipment, power lines, power equipment, ham radio transmitters, or equipment containing these or similar devices. 9) An ambient non-condensing humidity of 5 to 85%RH ) No large capacity electromagnetic switches or cables through which large current is flowing ) No water, oil or chemicals or where the vapors of these substances can come into direct contact with the controller. NOTICE ON THE WIRING ) The terminal block of KT, 8, 9, H, B series are designed to be wired from the left side (KT series are designed to be wired from the upper and lower direction). The lead wire must be inserted from the left side of the terminal, and fastened by the terminal screw. Use a solderless terminal with insulation sleeve that fits to the M screw. Wirepressed terminal Fork type Round type Max. 5.8mm.8inch Company name NICHIFU Co., Ltd. J.S.T. Mfg. Co., Ltd. NICHIFU Co., Ltd. J.S.T. Mfg. Co., Ltd. Part number.5y- VD.5-BA.5- V.5-.mm dia..inch dia. Max. 5.8mm.8inch Fastening torque. N m, Max.. N m..mm.inch ) Terminal fastening torque is approximately.n m to.n m (KT, 8, 9, H and B). For KT7 series by M. screw is less than.5n m and by M. screw.5n m respectively. ) Use a thermocouple and compensating lead wire according to the input specification of the controller. ) Use a -wire system of RTD according to the input specification of the controller. 5) This controller has no built-in power switch, circuit breaker or fuse. Therefore, it is necessary to install them in the circuit near the external controller. (Recommended fuse: Time-lag fuse, rated voltage 5V AC, rated current A) ) In the case of V AC/DC power supply, do not confuse the polarity when it is DC. 7) With the relay contact type, use an auxiliary electromagnetic switch externally according to the capacity of the load to protect the built-in relay contact. 8) When wiring, keep input wire (thermocouple, RTD, etc.) away from AC source and load wire to avoid external interference. 9) Turn the power supply to the instrument off before wiring or checking. Working or touching the terminal with the power switched on may result in Electric Shock which could cause severe injury or death. 5

16 KT (AKT,,7,8,9,H,B) ) Do not drop wire chips into the holes of vent when wiring, because they could cause fire, malfunction or trouble with the device. ) To prevent the unit from harmful effects of unexpected high level noise, it is recommended that a surge absorber be installed between the electromagnetic switch coils.. NOTICE ON THE MOUNTING ) Do not use excessive force while screwing in the mounting bracket of KT, 8, 9, H and B series. For KT, 8 and 9 series, recommended torque is approximately.n m. For KTH and B, recommended torque is approximately.5 to. N m. ) When mounting the KT7 series to the DIN rail, mount it in a lateral direction. Make sure a click is audible when fixed into place.. OPTIONAL HEATER BURN-OUT ALARM OUTPUT (KT, 7, 8, 9, H and B series) ) This alarm is not available for detecting current under phase control. ) Use the current transformer (CT) provided, and pass one lead wire of the heater circuit into the hole of CT. ) When wiring, keep CT wire away from AC source and load wire to avoid external interference. ) In three phase installations, ensure that R, S, and T are each connected to a -line CT that connects with CT (() ()) and CT (() (5)) terminals. CT Heater CT input terminal Power supply 5. Please use rod terminals for the terminal portion of the KT7 series. We recommend terminals made by Phoenix Contact. () to () are AI.5 8YE, AI. 8TQ, AI.5 8WH, AI.75 8GY, AI. 8RD, and AI.5 8BK. (5) to (9) are AI.5 8YE, AI. 8TQ, and AI.5 8WH. The screw tightening torque for () to () should be no more than.5 N m and for (5) to (9) it should be no more than.5 N m. Make sure no screw is loose. KT Monitor Available for download free of charge. Use it to acquire data from the KT series temperature controller. FEATURES. Parameters can be set from a computer.. Measurement data can be monitored from a computer.. Measurement data can be logged to a computer. Download from Applications Contributing to space savings of various heater control systems Injection molding machine Temperature controlled bath <Temperature Control System Configuration> Sensor Printing machine Heater Controller KTH Temperature Controller LCD curing oven Kitchen appliance Panasonic Electric Works Co., Ltd. Automation Controls Business Unit Head Office: 8, Kadoma, Kadoma-shi, Osaka 57-88, Japan All Rights Reserved 9 COPYRIGHT Panasonic Electric Works Telephone: Facsimile: Specifications are subject to change without notice. panasonic-electric-works.net/ac ARCTB7E 9-YT Printed in Japan.

1. Model number Page OUT2 (Heating/Cooling control) action [Reverse (Heating) action]

1. Model number Page OUT2 (Heating/Cooling control) action [Reverse (Heating) action] CONTENTS 1. Model number Page 1.1 Model number ----------------------------------------------------------------------------- 5 1.2 How to read the rated label ------------------------------------------------------------

More information

INSTRUCTION MANUAL FOR PROGRAMMABLE CONTROLLER PCD-33A

INSTRUCTION MANUAL FOR PROGRAMMABLE CONTROLLER PCD-33A INSTRUCTION MANUAL FOR PROGRAMMABLE CONTROLLER PCD-33A Preface Thank you for purchasing our Programmable Controller PCD-33A. This manual contains instructions for the mounting, functions, operations and

More information

1. Model number 1.1 Explanation of model number A K T 4 1. Phone: Fax: Web:

1. Model number 1.1 Explanation of model number A K T 4 1. Phone: Fax: Web: Instruction manual Temperature Controller KT4 No.KT41E9 200.08 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. SAFETY PRECAUTIS Be sure

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16A & SHIMADEN DIGITAL INDICATORS approved,ul applied BASIC FEATURES compliance DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large

More information

General Specifications

General Specifications General Specifications Model UT, UT Temperature Controller GS CE-E GENERAL UT series temperature controllers provide only the functions and size you require for your application. /6 DIN sizes is available.

More information

RT-3 UNIT RELAY 4-POINT TERMINAL

RT-3 UNIT RELAY 4-POINT TERMINAL Slim, Space-saving, -point Unit Relay RT-3 UNIT RELAY -POINT TERMINAL [PA Relay type, PhotoMOS Power (Voltage sensitive type)] RT-3 Unit relay -point Terminal [PA relay, PhotoMOS Power (Voltage sensitive

More information

RT-3 UNIT RELAY 4-POINT TERMINAL

RT-3 UNIT RELAY 4-POINT TERMINAL Slim, Space-saving, -point Unit Relay RT-3 UNIT RELAY -POINT TERMINAL [PA-N Relay type, PhotoMOS Power (Voltage sensitive type)] -point Terminal [PA-N relay, PhotoMOS Power (Voltage sensitive type)] Mountable

More information

PROGRAMMABLE CONTROLLER PCA1 INSTRUCTION MANUAL

PROGRAMMABLE CONTROLLER PCA1 INSTRUCTION MANUAL PROGRAMMABLE CONTROLLER PCA1 INSTRUCTION MANUAL Preface Thank you for purchasing our programmable controller PCA1. This manual contains instructions for the mounting, functions, operations and notes when

More information

Temperature Controllers E5 J

Temperature Controllers E5 J Temperature Controllers Advanced PID Controller with Fuzzy Logic-Based Adaptive Tuning Provides Optimum Performance Available in 3 standard DIN sizes: Choose 1/4, 1/8 and 1/16 DIN Fuzzy adaptive tuning

More information

Digital Controller Intelligent, User-friendly Digital Controller and Programmer Controlled with ease with a support software which is input via the communication jack on the front panel. Minute adjustment

More information

SHIMADEN PROGRAM CONTROLLER

SHIMADEN PROGRAM CONTROLLER Shimaden, Temperature and Humidity Control Specialists C %RH SHIMADEN PROGRAM CONTROLLER approved BASIC FEATURES Full multi-input and multi-range performance User selectable Thermocouple, RTD, V, mv and

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16 & SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large 2 mm bright

More information

General Specifications

General Specifications General Specifications GS 77J01Q08-01E Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dual-output Types) General This plug-in type pulse to analog converter

More information

MICRO-CONTROLLER X (48 48 mm)

MICRO-CONTROLLER X (48 48 mm) PX series digital temperature controller MICRO-CONTROLLER X ( mm) DATA SHEET PXG PXG is a compact size temperature controller of front panel size mm. To cope with any of versatile uses as a temperature

More information

Palm-sized, 16-channel Relay Terminals

Palm-sized, 16-channel Relay Terminals Palm-sized, -channel Relay Terminals RELAY TERMINAL FEATURES. Possible to select relay for use in the relay terminal in accordance with load. [Mountable relay: PA relay and Power PhotoMOS (voltage sensitive

More information

Multi-point Temperature Controller

Multi-point Temperature Controller Multi-point Temperature Controller Controls Up to Eight Zones, Built-in DeviceNet Communications Applications include plastic injection and extrusion machines, and continuous temperature control processes

More information

General Specifications

General Specifications General Specifications Model UM330 Digital Indicator with Alarms GS 05F0D00E General Model UM330 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent

More information

Fuzzy Temperature Controllers E5AF

Fuzzy Temperature Controllers E5AF Fuzzy Temperature Controllers 1/4 DIN Controller Combines Fuzzy and PID Control For Fast Response to Process Disturbances Advanced PID control provides optimal response during start-up and steadystate

More information

General Specifications

General Specifications General Specifications GS 05F01D01E MODEL UM351 Digital Indicator with Alarms with Active Color PV Display General Model UM351 Digital Indicator with Alarms is a precision alarm instrument provided with

More information

MICRO-CONTROLLER X (96 96 mm)

MICRO-CONTROLLER X (96 96 mm) PX series digital temperature controller MICRO-CONTROLLER X ( mm) DATA SHEET PXG PXG is a compact size temperature controller of front panel size mm. To cope with any of versatile uses as a temperature

More information

General Specifications

General Specifications General Specifications MODEL UM0 Digital Indicator with Alarms GS 0F0D00E General Model UM0 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent monitoring

More information

CompoBus/D-type Digital Controller

CompoBus/D-type Digital Controller CompoBus/D-type Digital Controller Digital Controller for the CompoBus/D and Conforming the DeviceNet Conforms the DeviceNet and connects a Programmable Controller without any programming. High performance

More information

High capacity SSR, both tab and screw terminals available

High capacity SSR, both tab and screw terminals available (A, 15A, A type) (3A, A type) High capacity SSR, both tab and screw terminals available RELAYS FEATURES 1. Two types of terminal shape: Plug-in terminal and Screw terminal (3 A, A is screw terminal types

More information

SHIMADEN DIGITAL INDICATOR

SHIMADEN DIGITAL INDICATOR Shimaden, Temperature and Humidity Control Specialists C %RH Series SD24 & KR16A SHIMADEN DIGITAL INDICATOR BASIC FEATURES ohigh Accuracy ±0.1% FS+1 digit o1/1000ºc Resolution Indication Possible (Pt input

More information

SHIMADEN DIGITAL CONTROLLER

SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists C %RH Series SR9 SHIMADEN DIGITAL CONTROLLER ASIC FEATURES Multi-input and multi-range performance Large mm bright display (SR9) Readable from a distance

More information

General Specifications

General Specifications General Specifications Model UM350 Digital Indicator with Alarms GS 05F0D00E General Model UM350 Digital Indicator with Alarms is a precision alarm instrument with universal input. For excellent monitoring

More information

General Specifications

General Specifications General Specifications GS 0F01D0E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision 1/8 DIN alarm instrument provided with

More information

General Specifications

General Specifications General Specifications GS 0F01D01E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision alarm instrument provided with universal

More information

General Specifications

General Specifications General Specifications MODEL UT50L Limit Controller GS 5DD-0E Overview The UT50L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user.

More information

MICRO-CONTROLLER X (48 96 mm)

MICRO-CONTROLLER X (48 96 mm) PX series digital temperature controller MICRO-CONTROLLER X ( mm) DATA SHEET PXG PXG is a compact size temperature controller of front panel size mm. To cope with any of versatile uses as a temperature

More information

PARM-SIZED, 16-CHANNEL RELAY TERMINALS

PARM-SIZED, 16-CHANNEL RELAY TERMINALS Pressure connector connect type Wire-direct connect type PARM-SIZED, -CHANNEL RELAY TERMINALS FEATURES Compact, space-saving design: The Relay Terminal with I/O channels measures only (W) (D) (H) mm (W).

More information

DIGITAL PROGRAM CONTROLLER

DIGITAL PROGRAM CONTROLLER KP1000 SERIES DIGITAL PROGRAM CONTROLLER The KP1000 series is a 96x96mm digital program controller with the indicating accuracy of ±0.1%, the control cycle of approximately 0.1 seconds and maximum 19 program

More information

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists SERIES SR25 MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER High Accuracy ±0.1% High Sampling Cycle 0.1 sec. Auto-Tuning

More information

General Specifications

General Specifications General Specifications GS 77J0A070E Model VJA7 Distributor (Multifunction) (Isolated Singleoutput and Isolated Dualoutput Types) Overview This plugin type distributor is used in combination with wire type

More information

TTM-339 TTM-339 PROGRAM CONTROLLER

TTM-339 TTM-339 PROGRAM CONTROLLER TTM-339 TTM-339 PROGRAM CONTROLLER TTM-339 PROGRAM CONTROLLER TTM-339 COMPACT SIZE PROGRAM CONTROLLER WITH HIGH FUNCTIONALITY AND HIGH PERFORMANCE Features Program Controller Specifications A liquid crystal

More information

Models UT350/UT320 Digital Indicating Controllers

Models UT350/UT320 Digital Indicating Controllers User s Manual Models UT350/UT320 Digital Indicating Controllers User s Manual IM 05D01D02-41E IM 05D01D02-41E 4th Edition Blank Page Introduction i Thank you for purchasing the UT350/UT320

More information

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure New Product News Measuring & Monitoring Relays K8AK/K8DS Series DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays Compact 22.5 mm and 17.5 mm housings Resistant to high-frequency

More information

DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification

DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification 01 May 20 30-10-10--EN Page 1 of DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification Overview The DC1000 Series are microprocessorbased controllers designed with a high degree of

More information

PROCESS & TEMPERATURE CONTROLLERS

PROCESS & TEMPERATURE CONTROLLERS PROCESS & TEMPERATURE CONTROLLERS NOVA PD54 Series Thermocouple, RTD, & Process Inputs High Accuracy Auto-Tuning PID Heating & Cooling Models Universal Power Supply 1-24 VAC Up to 3 Relays & 2 Analog Outputs

More information

MODEL: TC10EM. Temperature Controller TC10 Series

MODEL: TC10EM. Temperature Controller TC10 Series Temperature Controller TC0 Series TEMPERTURE CONTROLLER (Modbus, 5 digit, LED display type, size 9 x 9 mm) Functions & Features Two PID controllers* Universal input x points, control output x points, discrete

More information

Temperature Controller SA100 Instruction Manual ! WARNING SYMBOLS NOTICE CAUTION

Temperature Controller SA100 Instruction Manual ! WARNING SYMBOLS NOTICE CAUTION Temperature Controller SA00 Instruction Manual IMR0J0-E6 Thank you for purchasing this RKC product. In order to achieve maximum performance and ensure proper operation of the instrument, carefully read

More information

Series Valve Temperature Controller. Instruction Sheet

Series Valve Temperature Controller. Instruction Sheet 2013/10/03 Series Valve Temperature Controller Instruction Sheet Thank you very much for choosing Delta DTV series valve temperature controller. Please read this instruction sheet before using your DTV

More information

UNICONT. PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1. pmg4111a0600p_01 1 / 24. ST edition

UNICONT. PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1. pmg4111a0600p_01 1 / 24. ST edition UNICONT PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1 ST edition pmg4111a0600p_01 1 / 24 TABLE OF CONTENTS 1. GENERAL DESCRIPTION... 3 2. ORDER CODE... 3 3. TECHNICAL DATA...

More information

DIGITAL INDICATING CONTROLLER

DIGITAL INDICATING CONTROLLER DB00 SERIES DIGITAL INDICATING CONTROLLER The DB00 series is a digital indicating controller with the indicating accuracy of ±0.% and the control cycle of approximately 0. seconds. Various functions including

More information

High Performance Process & Temperature Controllers

High Performance Process & Temperature Controllers C22 C62 C82 C83 High Performance Process & Temperature Controllers C72 C42 R22 01. Multi Color LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. 200 msec Sampling Rate 04. True Universal

More information

DC1010/DC1020/DC1030/DC1040

DC1010/DC1020/DC1030/DC1040 05/0 0-10-10-0-EN Page 1 of DC1010/DC1020/DC100/DC1040 DIGITAL CONTROLLERS Specification Overview The DC1000 Series are microprocessorbased controllers designed with a high degree of functionality and

More information

Analogue temperature controllers

Analogue temperature controllers Analogue temperature controllers CT8A Input by J-K thermo-couple or by thermo-resistance Pt 00 (-wire) regulation modes : ON/OFF or proportional derivative selected by wiring Relay output Specifications

More information

LT23A SERIES. Digital Indicating Controller PSE x48mm compact body Easy to use small size controller at reasonable price CE RoHS compliance

LT23A SERIES. Digital Indicating Controller PSE x48mm compact body Easy to use small size controller at reasonable price CE RoHS compliance Digital Indicating Controller LTA SERIES 48x48mm compact body Easy to use small size controller at reasonable price CE RoHS compliance LT A series is a 4848mm digital indicating controller with indicating

More information

Models UT550/UT520 Digital Indicating Controllers User s Manual for Loop Control for Backup

Models UT550/UT520 Digital Indicating Controllers User s Manual for Loop Control for Backup Instruction Manual Models UT550/UT520 Digital Indicating Controllers User s Manual for Loop Control for Backup IM 05D01C02-45E IM 05D01C02-45E 1st Edition Blank Page Introduction Thank you

More information

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485)

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485) Module type High-speed Digital ler SRX SRX General Description The SRX is a module type digital controller with a super high speed sampling of control updating cycle time of ms (0.0 sec). Dual loop control

More information

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional) Temperature Controller with Built-in SSR SB SB General Description SB is a channel temperature controller with Built-in SSR (Solid state relay) designed for flexible heating solutions such as heat trace

More information

PROGRAMMABLE CONTROLLER

PROGRAMMABLE CONTROLLER SERIES FP21 High Accuracy ±0.1% Programmable 9 Patterns and 9 Steps (81 Steps Max.) Auto-Tuning PID RA / DA Selectable User-Selectable Inputs (Thermocouple) User-Selectable Ranges Programmable Scaling

More information

PROGRAMMABLE CONTROLLER

PROGRAMMABLE CONTROLLER Shimaden, Temperature and Humidity Control Specialists C %RH Series FP2 PROGRAMMABLE CONTROLLER approved UL applied BASIC FEATURES 2-channel controller (Basic type: 1-channel controller) Independent 2-loop

More information

MODEL: R30US4. Remote I/O R30 Series

MODEL: R30US4. Remote I/O R30 Series Remote I/O R30 Series UNIVERSAL INPUT MODULE (4 points, isolated) Functions & Features 4 points universal input I/O module Isolation between the channels Input range of each channel is individually adjustable

More information

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model

More information

TV-15, 30 AMP (1 Form A) Power Relay

TV-15, 30 AMP (1 Form A) Power Relay VDE TV-, 3 AMP ( Form A) Power Relay RELAYS Form A Plug-in type Form A type also available with 48A contact capacity FEATURES. Excellent resistance to contact welding Owing to the pre-tension and kick-off

More information

Digital Temperature Controller

Digital Temperature Controller New Product Digital Temperature Controller E5CC/E5EC/E5AC The new standard in temperature control is higher in every respect E5CC (48 48 mm) / E5EC (48 96 mm) / E5AC (96 96 mm) Large White Display That's

More information

DIN48 SIZE ANALOG MULTI-RANGE CYCLIC TWIN TIMERS

DIN48 SIZE ANALOG MULTI-RANGE CYCLIC TWIN TIMERS DIN SIZE ANALOG MULI-ANGE CYCLIC WIN IMES UL File No.: E122222 CSA File No.: L39291 FEAUES A single twin timer unit that repeats (variable) ON/OFF. Multiple ranges with a.1 s to 5 h time specification

More information

Excellent low-cost Process & Temperature Controllers

Excellent low-cost Process & Temperature Controllers C22 C62 C82 C83 Excellent low-cost Process & Temperature Controllers C72 C42 R22 01. High Quality LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. The Fast Sampling Rate in 200

More information

Module Type Controller SRZ. Instruction Manual IMS01T04-E6 RKC INSTRUMENT INC.

Module Type Controller SRZ. Instruction Manual IMS01T04-E6 RKC INSTRUMENT INC. Module Type Controller SRZ Instruction Manual RKC INSTRUMENT INC. IMS01T04-E6 is a registered trademark of Schneider Electric. Company names and product names used in this manual are the trademarks or

More information

ADAM 4000/4100 Series

ADAM 4000/4100 Series ADAM 4000/4100 Series Common Dimensions Communication RS-485 (2-wire) to host Speeds: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps (ADAM-4080, ADAM-4080D only support up to 38400 bps) Max. communication

More information

Models UT550/UT520 Digital Indicating Controllers User s Manual for Single-loop Control

Models UT550/UT520 Digital Indicating Controllers User s Manual for Single-loop Control User s Manual Models UT550/UT520 Digital Indicating Controllers User s Manual for Single-loop Control IM 05D01C02-41E IM 05D01C02-41E 3rd Edition Blank Page Introduction i Thank you for purchasing

More information

General Specifications

General Specifications General Specifications GS 05P01F31-01EN UT32A Digital Indicating Controller (Entry model) Functional Enhancement Overview The UT32A entry model digital indicating controller is an easily configurable single-loop

More information

Z4D-F. LED-type Micro Displacement Sensor with Many Features in a Compact Body. Micro Displacement Sensor. Ordering Information.

Z4D-F. LED-type Micro Displacement Sensor with Many Features in a Compact Body. Micro Displacement Sensor. Ordering Information. / Length Micro Sensor LED-type Micro Sensor with Many Features in a Compact Body Compact body only /4th the volume of our previous product. % cost reduction over our previous product. High performance

More information

Slim type SSR for 1 A and 2 A control AQ-G RELAYS

Slim type SSR for 1 A and 2 A control AQ-G RELAYS VDE Slim type SSR for 1 A and A control AQ-G RELAYS ORDERING INFORMATION current 1: 1 A : A RoHS compliant voltage : 75 to 6 Vrms 1: Zero-cross (3, V) : Random (3, V) Control voltage 5: to 6 V DC 1: 9.6

More information

Digital Temperature Controller

Digital Temperature Controller www.hynux.com Digital Temperature Controller Economical price Convenient functions High speed sampling High accuracy temperature controlling AX2 AX3 AX4 AX7 AX9 Actualized the highly accurate temperature

More information

Model Number Structure

Model Number Structure Digital Controller CSM DS_E_3_1 Advanced Digital Controllers Ideal for Worldwide Use Modular structure High-accuracy: 100 ms sampling (for analog input) Auto-tuning and fuzzy self-tuning Conforms to international

More information

High Capacity of Max. 1,000 V DC Cut-off Possible

High Capacity of Max. 1,000 V DC Cut-off Possible EP (A (AEP) and 80A types) High Capacity of Max.,000 V DC Cut-off Possible EP RELAYS (AEP) A PC board type A TM type New A TM type 80A type 300A type Compliance with RoHS Directive FEATURES. High-, high-current

More information

DIN rail mounting temperature controller with current transformer input deltadue series D1 line

DIN rail mounting temperature controller with current transformer input deltadue series D1 line BT.. D/E S E R I E S DIN rail mounting temperature controller with current transformer input deltadue series D line The controller with load control The deltadue series includes a powerful DIN rail mounting

More information

Phase-sequence Phase-loss Relay

Phase-sequence Phase-loss Relay Phase-sequence Phase-loss Relay K8AB-PH Three-phase Phase-sequence Phase-loss Relay Using Voltage Detection Method Prevents reverse motor rotation due to incorrect wiring. Distinguishes between positive

More information

Capacitive Proximity Sensor

Capacitive Proximity Sensor Capacitive Proximity Sensor Compact and Ideal for Robot Hands and Various Built-in Applications for LCD, Wafer, and PDP (Plasma Display Panel) Detection Flat head is only 5.5-mm thick. Robot Cable ensures

More information

Model Number Structure

Model Number Structure Single-phase Voltage Relay CSM DS_E_3_1 Ideal for voltage monitoring for industrial facilities and equipment. Monitor for overvoltages or undervoltages. Manual resetting and automatically resetting supported

More information

PROGRAMMABLE SIGNAL CONDITIONER SA SERIES SAW SERIES INSTRUCTION MANUAL

PROGRAMMABLE SIGNAL CONDITIONER SA SERIES SAW SERIES INSTRUCTION MANUAL PROGRAMMABLE SIGNAL CONDITIONER SA SERIES SAW SERIES STRUCTION MANUAL Preface Thank you for purchasing the Programmable Signal Conditioner SA series and SWA series. This manual contains instructions for

More information

General Specifications

General Specifications General Specifications UM33A Digital Indicator with Alarms [Style: S9] Overview The UM33A digital indicator with Alarms employ an easy-to-read, 14-segment large color LCD display, along with navigation

More information

Single Loop Controller SDC35/36

Single Loop Controller SDC35/36 No. CP SS 180E Single Loop Controller SDC35/36 Features The DigitroniK SDC35/36 is a digital indicating controller featuring multi-range inputs and PID control system using new algorithms "RationaLOOP"

More information

INSTRUCTION MANUAL HAND-HELD DIGITAL THERMO-HYGROMETER DFT-700-M

INSTRUCTION MANUAL HAND-HELD DIGITAL THERMO-HYGROMETER DFT-700-M INSTRUCTION MANUAL HAND-HELD DIGITAL THERMO-HYGROMETER DFT-700-M No.DFT71E4 2008.11 To prevent accidents arising from the misuse of this product, please ensure the operator receives this manual. Notes

More information

SHIMADEN PROGRAMMABLE CONTROLLER

SHIMADEN PROGRAMMABLE CONTROLLER SHIMADEN PROGRAMMABLE CONTROLLER Shimaden, Temperature and Humidity Control Specialists SERIES FP21 High Accuracy ±0.1% Programmable 9 Patterns and 9 Steps (81 Steps Max.) Auto-Tuning PID RA / DA Selectable

More information

Process Controller. PX series INSTRUCTION MANUAL. Thank you for the purchase of HANYOUNG product. Please read this manual carefully.

Process Controller. PX series INSTRUCTION MANUAL. Thank you for the purchase of HANYOUNG product. Please read this manual carefully. Process Controller PX series INSTRUCTION MANUAL Thank you for the purchase of HANYOUNG product. Please read this manual carefully. Contents. SAFETY INFORMATION. INSTRUCTION 3. ORDERING INFORMATION 4. SPECIFICATION

More information

PROGRAM CONTROLLER OUTLINE

PROGRAM CONTROLLER OUTLINE Specifications Sheet No.SPEC-1232E (1st Edition) EC1200A PROGRAM CONTROLLER OUTLINE The EC1200 can, totally and with high precision, control and monitor such factors as temperature, temperature balance

More information

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS 20 AMP POWER RELAY RELAYS a 3 1.4 5 a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A V AC resistive and 1.5 kw 3 phase 220 V AC motor loads High contact reliability after long use Usable with direct soldering,

More information

Panel Mount PLC. NEW standard: Timer + Counter + Temperature Controller + PLC. The FP-e PLC comes in the following three types

Panel Mount PLC. NEW standard: Timer + Counter + Temperature Controller + PLC. The FP-e PLC comes in the following three types Panel Mount PC NEW standard: Timer Counter Temperature Controller PC From the makers of the first SIM FP0 PC, Panasonic Electric Works is proud to introduce the industry's first panel mount PC, the FP-e.

More information

Process and Temperature Controllers

Process and Temperature Controllers Process and Temperature Controllers www.durexindustries.com Input Input Input break action Input short action Sampling time Influence of external resistance Influence of lead resistance PV bias Input

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Linear Proximity Sensor with High-accuracy Resolution Resolution is 0.05% of the maximum sensing distance. The model with a sensing distance of 1.2 mm ensures a resolution of

More information

Model UP350 Program Controller

Model UP350 Program Controller User s Manual Model UP350 Program Controller User s Manual IM 05E01D02-41E IM 05E01D02-41E 2nd Edition Blank Page Introduction i Thank you for purchasing the UP350 program controller. How to

More information

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions ELECTRONIC SPEED CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 WIRING

More information

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4] Tension-Clamp Ultra-Slim Signal Conditioners M6S Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection Universal input (mv, V, ma, T/C, RTD and potentiometer)

More information

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

MODEL: M2XU MODEL: M2XU [1][2] [3][4] Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and

More information

Fuzzy Temperature Controllers E5EF

Fuzzy Temperature Controllers E5EF Fuzzy Temperature lers EEF / DIN lers Combine Fuzzy and PID For Fast Response to Process Disturbances dvanced PID control for optimal response during startup and steadystate operation Fuzzy and PID control

More information

Digital indicator for panel mounting With multi-function input Model DI25

Digital indicator for panel mounting With multi-function input Model DI25 Accessories Digital indicator for panel mounting With multi-function input Model DI25 WIKA data sheet AC 80.02 Applications Plant construction Machine tools Plastics technology and processing Ventilation

More information

APPENDIX APPENDIX A 1

APPENDIX APPENDIX A 1 A 1 SPECIFICATIONS Ratings Supply voltage 100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz/24 VDC Operating voltage range 85 to 110% of rated supply voltage Power consumption 7VA 4VA/2.5W Sensor input Thermocouple

More information

PID CONTROLLERS LT SERIES

PID CONTROLLERS LT SERIES PID CONTROLLERS LT SERIES The Axis family of microprocessor based controllerscombine a high degree of functionality and reliability at a very low price, in 4 different formats : 1/16 DIN, 1/8 DIN, 1/ 4

More information

MODEL: M1EXT. with Display M1E Series

MODEL: M1EXT. with Display M1E Series 2 Channel Super-mini Signal Conditioners with Display M1E Series THERMOCOUPLE TRANSMITTER (2 channels, PC programmable) Functions & Features Accepts direct input from a thermocouple and provides a linearized

More information

SR90 Series. (SR91, SR92, SR93, SR94) Digital Controller. Instruction Manual

SR90 Series. (SR91, SR92, SR93, SR94) Digital Controller. Instruction Manual SR90 Series (SR9, SR9, SR9, SR94) Digital Controller Instruction Manual Thank you for purchasing a Shimaden product. Please check that the delivered product is the correct item you ordered. Please do not

More information

SHIMADEN DIGITAL CONTROLLER

SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists C %RH SHIMADEN DIGITAL CONTROLLER & C US approved BASIC FEATURES High accuracy: ± (.% FS + 1 digit) Only SR ( x ) Large mm bright display Make reading

More information

Module Type Controller SRX. Communication Instruction Manual IMS01N01-E6 RKC INSTRUMENT INC.

Module Type Controller SRX. Communication Instruction Manual IMS01N01-E6 RKC INSTRUMENT INC. Module Type Controller SRX Communication Instruction Manual RKC INSTRUMENT INC. IMS01N01-E6 is a registered trademark of Schneider Electric. Company names and product names used in this manual are the

More information

Distributed by: www.jameco.com -8-83-22 The content and copyrights of the attached material are the property of its owner. VDE TV-, AMP ( Form A) Power Relay HE RELAYS.299 3.8.9 RoHS Directive compatibility

More information

30 AMP POWER RELAY WITH SPACE SAVING DESIGN

30 AMP POWER RELAY WITH SPACE SAVING DESIGN VDE 3 AMP POWER RELAY WITH SPACE SAVING DESIGN JH-RELAYS 2..2 3.. FEATURES Many safety-oriented characteristics incorporated Contact gap: more than 3 mm. inch for Form A and 2 Form A Breakdown voltage

More information

AQ-R SOLID STATE RELAY FEATURES

AQ-R SOLID STATE RELAY FEATURES (A 5A A type) SOLID STATE RELAY FEATURES. Two types of terminal shape: Plug-in terminal and Screw terminal ( A A is screw terminal types only). Flat type of SSR possible by aluminium printed circuit board.

More information

Process displays For standard signals, temperature, resistance measurement

Process displays For standard signals, temperature, resistance measurement Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions

More information

Solid-state Twin Timer

Solid-state Twin Timer Solid-state Twin Timer -F Operates in flicker- or flicker- start mode with one Unit. Independent - and -time settings. Combinations of long - or -time and short - or -time setting are possible. Long time

More information