60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay
|
|
- Adelia Sherman
- 6 years ago
- Views:
Transcription
1 Series - General purpose relays - 0 A Features Plug-in mount 0 A General purpose relay.. & pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listed (certain relay/socket combinations) Contact material options Lockable test button with mechanical flag indicator (preferred version) 90 series sockets, coil EMC suppression and timer accessories pole - 0 A power contacts pin plug-in pole - 0 A power contacts pin plug-in 9 A Contact specification Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load AC VA Rated load AC (0 V AC) VA Single phase motor rating (0 V AC) kw Breaking capacity DC: 0/0/0 V A Minimum switching load mw (V/mA) Standard contact material Coil specification Nominal voltage (U N ) V AC (0/ Hz) V DC Rated power AC/DC VA (0 Hz)/W Operating range AC DC Holding voltage AC/DC Must drop-out voltage AC/DC Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation between coil and contacts (./0 µs) kv between open contacts V AC Ambient temperature range C Environmental protection (according to type) CO (DPDT) CO (PDT) 0/0 0/0 0/00 0/00,00, /0./0. 0/0./0. 00 (0/) 00 (0/) AgNi AgNi /../. 0. U N /0. U N 0. U N /0. U N 0. U N /0. U N 0. U N /0. U N 0 0 / / /9 9/9..,000, RT I RT I
2 Series - General purpose relays - 0 A Features Plug-in mount - A Bifurcated contacts for low level switching & pole changeover contacts Cadmium Free contacts (Gold plated Silver Nickel) AC coils & DC coils Lockable test button with mechanical flag indicator (preferred version) 90 series sockets, coil EMC suppression and timer accessories pole - A bifurcated contacts pin plug-in pole - A bifurcated contacts pin plug-in 9 A Contact specification Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load AC VA Rated load AC (0 V AC) VA Single phase motor rating (0 V AC) kw Breaking capacity DC: 0/0/0 V A Minimum switching load mw (V/mA) Standard contact material Coil specification Nominal voltage (U N ) V AC (0/ Hz) V DC Rated power AC/DC VA (0 Hz)/W Operating range AC DC Holding voltage AC/DC Must drop-out voltage AC/DC Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation between coil and contacts (./0 µs) kv between open contacts V AC Ambient temperature range C Environmental protection (according to type) CO (DPDT) CO (PDT) /0 /0 0/00 0/00,00, /0./0. /0./0. 0 (/) 0 (/) AgNi + Au bifurcated contacts AgNi + Au bifurcated contacts /../. 0. U N /0. U N 0. U N /0. U N 0. U N /0. U N 0. U N /0. U N 0 0 / / /9 9/9..,000, RT I RT I
3 Series - General purpose relays - 0 A Features Flange mount 0 A General purpose relay Flange mount (Faston,.x0. mm termination) & pole changeover contacts AC coils & DC coils Cadmium Free contacts (preferred version) Contacts material options pole - 0 A power contacts Flange mount/faston.. pole - 0 A power contacts Flange mount/faston A 9 B A A 9 B A Contact specification Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load AC VA Rated load AC (0 V AC) VA Single phase motor rating (0 V AC) kw Breaking capacity DC: 0/0/0 V A Minimum switching load mw (V/mA) Standard contact material Coil specification Nominal voltage (U N ) V AC (0/ Hz) V DC Rated power AC/DC VA (0 Hz)/W Operating range AC DC Holding voltage AC/DC Must drop-out voltage AC/DC Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation between coil and contacts (./0 µs) kv between open contacts V AC Ambient temperature range C Environmental protection (according to type) CO (DPDT) CO (PDT) 0/0 0/0 0/00 0/00,00, /0./0. 0/0./0. 00 (0/) 00 (0/) AgNi AgNi /../. 0. U N /0. U N 0. U N /0. U N 0. U N /0. U N 0. U N /0. U N 0 0 / / /9 9/9..,000, RT I RT I
4 Series - General purpose relays - 0 A Ordering information Example: series plug-in relay, CO (PDT), V DC coil, test button and mechanical indicator. 0 A B C D Series Type = / pin plug-in = Faston (.x0. mm) with flange mount No. of poles = pole = pole Coil version = Current sensing = AC (0/ Hz) 9 = DC Coil voltage see coil specifications A: Contact material 0 = Standard = AgCdO = AgNi + Au ( µm) B: Contact circuit 0 = CO (npdt) = Bifurcated contacts./ - A only Selecting features and options: only combinations in the same row are possible. Preferred selections for best avaliability are shown in bold. Type Coil version A B C D./ AC AC 0-0 / AC AC 0 - / DC DC 0-0 / DC DC 0 - / current sensing / AC-DC D: Special versions 0 = Standard C: Options 0 = None = Mechanical indicator = LED (AC) = Lockable test button + mechanical indicator = Lockable test button + LED (AC) = Lockable test button + LED (AC) + mechanical indicator = LED + diode (DC, polarity positive to pin ) = Lockable test button + LED + diode (DC, polarity positive to pin ) = Lockable test button + LED + diode (DC, polarity positive to pin ) + mechanical indicator Descriptions: Options and Special versions /0 A /0 A C: Option,, LED (AC) C: Option,, LED + diode (DC, polarity positive to pin ) Lockable test button and mechanical flag indicator (000) The dual-purpose Finder test button can be used in two ways: Case ) The plastic pip (located directly above the test button) remains intact. In this case, when the test button is pushed, the contacts operate. When the test button is released the contacts return to their former state. Case ) The plastic pip is broken-off (using an appropriate cutting tool). In this case, (in addition to the above function), when the test button is pushed and rotated, the contacts are latched in the operating state, and remain so until the test button is rotated back to its former position. In both cases ensure that the test button actuation is swift and decisive.
5 Series - General purpose relays - 0 A Insulation Insulation according to EN 0- ed. insulation rated voltage V 0 00 rated impulse withstand voltage kv ( pole). ( pole) ( pole). ( pole) pollution degree overvoltage category III III Insulation between coil and contacts (./0 µs) kv. between open contacts V AC,000 between adjacent contacts V AC,000 Conducted disturbance immunity Burst (...0)ns, khz, on - A EN level ( kv) Surge (./0 µs) on - A (differential mode) EN level ( kv) Other data Bounce time: NO/NC ms / Vibration resistance ( )Hz, max. ± mm: NO/NC g/g / Shock resistance g 0 Power lost to the environment pole pole without contact current W.. with rated current W.. Contact specification F - Electrical life (AC) v contact current H - Maximum DC breaking capacity 0 0 Cycles 0 Resistive load - cosϕ = Inductive load - cosϕ = 0. DC breaking current (A) 0 0. contacts in series 0 0 (A) DC voltage (V) When switching a resistive load (DC) having voltage and current values under the curve, an electrical life of 00 0 can be expected. In the case of DC loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC load. Note: the release time for the load will be increased. Coil specifications DC coil data Nominal Coil Operating range Resistance Rated coil voltage code consumption U N U min U max R I at U N V V V Ω ma ,0. 9.0, , , ,00. AC coil data Nominal Coil Operating range Resistance Rated coil voltage code consumption U N U min U max R I at U N (0Hz) V V V Ω ma , , , , ,00
6 Series - General purpose relays - 0 A Coil specifications R - DC coil operating range v ambient temperature U U N.0 R - AC coil operating range v ambient temperature U U N ( C) ( C) - Max. permitted coil voltage. - Min. pick-up voltage with coil at ambient temperature. - Max. permitted coil voltage. - Min. pick-up voltage with coil at ambient temperature. Current sensing version L N C K L L S Typical application with current sensing relays. An open circuit filiment of lamp L is detected by the current sensing relay coil (K) which causes the back-up safety lamp L to be energised, and indication of failure at the control panel via lamp S. Example: navigation light. L = Light L = Safety light S = Control light K = Relay Current sensing DC coil data Coil code I min (A) I N (A) I max (A) R (Ω) Current sensing AC coil data Coil code I min (A) I N (A) I max (A) R (Ω) Other types of current sensing relays are available on request. Accessories Sheet of marker tags for relay types. and., plastic, tags, x mm 0. 0.
7 90 Series - Socket overview for series relays See page Screw terminal (Box clamp) socket Panel or mm rail - Coil indication and EMC Double terminal (EN 00) mount suppression modules - Jumper link - Timer modules - Metal retaining clip Screw terminal (Box clamp) socket Panel or mm rail - Coil indication and EMC 90.. (EN 00) mount suppression modules - Metal retaining clip See page Screw terminal (Box clamp) socket Panel or mm rail - Metal retaining clip (EN 00) mount See page Screw terminal (Box clamp) socket Panel or mm rail - Metal retaining clip 90.. (EN 00) mount See page Screw terminal (Plate clamp) socket Panel or mm rail - Metal retaining clip 90.. (EN 00) mount See page Flange mount solder socket M screw fixing 90.. See page PCB socket PCB See page 9 9
8 90 Series - Sockets and accessories for series relays 90.0 NO NC NC A 90.0 NO COIL COM COIL COM COIL.. Screw terminal (Box clamp) socket panel or mm rail (EN 00) mount Blue Black Blue Black For relay type.. Accessories Metal retaining clip way jumper link Identification tag Modules (see table below) 99.0 Timer modules (see table below).00,.0,.0 0 A - 0 V kv AC Protection category IP 0 Ambient temperature C Screw torque Nm 0. Wire strip length mm 0 Max. wire size for 90.0 and 90.0 sockets solid wire stranded wire mm x / x. x / x. AWG x0 / x x / x NO NC NO NC NO NC 9 A 0 COIL COM COM START 90.0 COM COIL way jumper link for 90.0 and 90.0 sockets A - 0 V *Modules in Black housing are available on request. 90 series timer modules (see technical data pages //) Multi-voltage: ( 0)V AC/DC; Multi-functions: AI, DI, SW, BE, CE, DE, EE, FE; (0.0 s 00 h) Mono-function: ( )V AC/DC; function AI; (. s min) Mono-function: ( )V AC/DC; function DI; (. s min) coil indication and EMC suppression modules (see technical data pages /) Blue* Diode (+, standard polarity) (...0)V DC Diode (+A, non-standard polarity) (...0)V DC LED (...)V DC/AC LED (...)V DC/AC LED (0...0)V DC/AC LED + Diode (+, standard polarity) (...)V DC LED + Diode (+, standard polarity) (...)V DC LED + Diode (+, standard polarity) (0...0)V DC LED + Diode (+A, non-standard polarity) (...)V DC LED + Diode (+A, non-standard polarity) (...)V DC LED + Diode (+A, non-standard polarity) (0...0)V DC LED + Varistor (...)V DC/AC LED + Varistor (...)V DC/AC LED + Varistor (0...0)V DC/AC RC circuit (...)V DC/AC RC circuit (...)V DC/AC RC circuit (0...0)V DC/AC Residual current by-pass ( kω/w) (0...0)V AC
9 90 Series - Sockets and accessories for series relays 90. Screw terminal (Box clamp) socket panel or mm rail (EN 00) mount Blue Black Blue Black For relay type.. Accessories Metal retaining clip (supplied with socket - packaging code SMA) 090. Modules (see table below) A - 0 V kv AC Protection category IP 0 Ambient temperature C 0 +0 Screw torque Nm 0. Wire strip length mm 0 Max. wire size for 90.0 and 90. sockets solid wire stranded wire mm x / x. x / x. AWG x0 / x x0 / x NO NC NC NO NO NC NO NC NO NC A COIL COM COM COIL 0 A 0 COIL COM COM COM COIL *Modules in Black housing are available on request. Green LED is standard. Red LED available on request coil indication and EMC suppression modules for 90.0 and 90. sockets See technical data pages / Blue* Diode (+, standard polarity) (...0)V DC Diode (+A, non-standard polarity) (...0)V DC LED (...)V DC/AC LED (...)V DC/AC LED (0...0)V DC/AC LED + Diode (+, standard polarity) (...)V DC LED + Diode (+, standard polarity) (...)V DC LED + Diode (+, standard polarity) (0...0)V DC LED + Diode (+A, non-standard polarity) (...)V DC LED + Diode (+A, non-standard polarity) (...)V DC LED + Diode (+A, non-standard polarity) (0...0)V DC LED + Varistor (...)V DC/AC LED + Varistor (...)V DC/AC LED + Varistor (0...0)V DC/AC RC circuit (...)V DC/AC RC circuit (...)V DC/AC RC circuit (0...0)V DC/AC Residual current by-pass ( kω/w) (0...0)V AC
10 90 Series - Sockets and accessories for series relays 90.. Screw terminal (Box clamp) socket panel or mm rail (EN 00) mount Blue Black Blue Black For relay type.. Accessories Metal retaining clip A - 0 V kv AC Protection category IP 0 Ambient temperature C 0 +0 Screw torque Nm 0. Max. wire size for 90.. and 90.. sockets solid wire stranded wire mm x / x x / x AWG x0 / x x0 / x NO NC NC NO NC NO com NC NC. Ø.. Ø. 9 NO NO A COIL COM COM COIL 9. A 0 COIL COM COM COIL Screw (Box clamp) terminal socket 90. (blue) 90. (blue) panel or mm rail (EN 00) mount For relay type.. Accessories Metal retaining clip (supplied with socket - packaging code SMA) A - 0 V kv AC Protection category IP 0 Ambient temperature C 0 +0 Screw torque Nm 0. Wire strip length mm Max wire size for 90. and 90. sockets solid wire stranded wire mm x / x. x / x. AWG x0 / x x0 / x 0 0 NO NC NC NO NC NO COM NC NC b a COIL COM COM COIL.9 b 9 0 a NO COIL COM COM COIL NO
11 90 Series - Sockets and accessories for series relays 90. Screw terminal (Plate clamp) socket panel or mm rail (EN 00) mount Blue Black Blue Black For relay type.. Accessories Metal retaining clip (supplied with socket - packaging code SMA) A - 0 V kv AC Protection category IP 0 Ambient temperature C 0 +0 Screw torque Nm 0. Wire strip length mm 0 Max. wire size for 90. and 90. sockets solid wire stranded wire mm x / x. x / x. AWG x / x x / x NO NC NC NO 0 NC NO com NC NC fl. = NO NO. = A COIL COM COM COIL A 0 COIL COM COM COIL Flange mount solder socket mount with M screw 90. (black) 90. (black) For relay type.. 0 A - 0 V kv AC 90. Ambient temperature C Ø PCB socket Blue Blue 90.. (Ø.mm) 90.. (Ø 9mm) For relay type.. 0 A - 0 V kv AC Ambient temperature C 0 +0 '"... '" A
12 90 Series - Sockets and accessories for series relays Packaging code How to code and identify retaining clip and packaging options for sockets. Code options according to the last three letters: 9 0. S M A A Standard packaging SM Metal retaining clip 9 0. Without retaining clip 9
13 Series General Purpose Relays 0 A ORDERING INFORMATION Example: a series P.C.B.relay, CO (PDT) with coil rated V DC Series No. of poles = CO (DPDT) = CO (PDT) Coil version = DC diode in parallel to coil (positive to pin ) = AC (0/ Hz) 9 = DC Contact material and contact circuit 00 = Standard 0 = AgCdO 0 = AgNi + µm Au Options 00 = Standard Type = P.C.B. Coil voltage 00 = V 0 = V 0 = V 0 = V 0 = V 0 = 0 V 0 = 0 V AC only 0 = 0 V AC only 0 = 0 V AC only OPTIONS Coil version = Option = 000 Option = Option =
62 Series - Power relays 16 A. Features / /
6 Series - Power relays 6 A Features 6. / 6.3 6.-0300 / 6.3-0300 Printed circuit mount 6 A Power relay & 3 Pole changeover contacts or NO ( 3 mm contact gap) AC coils & DC coils Reinforced insulation between
More information2 or 4 pole changeover contact Plug-in/Faston 187
56 Miniature power relays 56 Plug-in - Power relay, & 4 pole Flange mount option - (Faston 87, 4.8 x 0.5 mm termination) C coils & DC coils Lockable test button and mechanical flag indicator Cadmium Free
More information62 Series - Power relays 16 A. Features SERIES / / Printed circuit mount 16 A Power relay
62 Series - Power relays 16 62 SERIES Features 62.22 / 62.23 62.22-0300 / 62.23-0300 Printed circuit mount 16 Power relay 2 & 3 Pole changeover contacts or NO ( 3 mm contact gap) C coils & DC coils Reinforced
More information62.22 Copper side view
62 Power relays 16 62 Printed circuit mount 16 Power relay 2 & 3 Pole changeover contacts or NO ( 3 mm contact gap) C coils & DC coils Reinforced insulation between coil and contacts according to EN 60335-1,
More information2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)
46 Series - Relays for railway applications 8-16 A 46 SERIES Features Plug-in power relays: 8 A, 2 pole 16 A, 1 pole Complies with EN 45545-2:2013 (protection against fire of materials), EN 61373 (resistance
More information48 Series - Relay interface modules A. Features
Series - Relay interface modules 8-0 - 6 A Features & Pole relay interface modules, 5.8 mm wide. Ideal interface for PLC and electronic systems.3 - Pole 0 A.5 - Pole 8 A.6 - Pole 6 A coils or sensitive
More information48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12
48 Relay interface modules 8 A 48 2 CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12 2 CO 8 A s Relay with forcibly guided contacts according to EN 50205 Type 35 mm rail (EN
More information58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4
58 58 3 & 4 CO relay interface modules, 31 mm wide with Push-in terminals Ideal interface for PLC and electronic systems 58.P3 58.P4 Type 58.P3 3 CO 10 A Push-in terminals Type 58.P4 4 CO 7 A Push-in terminals
More information3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket
41 Series - Low profile PCB relays 8-12 - 16 A Features 41.31 41.52 41.61 1 & 2 Pole - Low profile (15.7 mm height) 41.31-1 Pole 12 A (3.5 mm pin pitch) 41.52-2 Pole 8 A (5 mm pin pitch) 41.61-1 Pole 16
More informationRelay interface modules A
4C SЕRIES Relay interface modules 8-10 - 16 A Escalators Road / tunnel lighting Hoists and cranes Carousel warehouses Control panels Panels for electrical distribution FINDER reserves the right to alter
More information38 Series - Relay interface modules A. Features /
Series - Relay interface modules 0.1-2 - 6-8 A Features 1 Pole - 6 A electromechanical relay interface modules, 6.2 mm wide. Ideal interface for PLC and electronic systems Sensitive DC coil or coil versions
More information30 A rated contacts Flange mount Faston 250 connections. 30 A rated contacts PCB mount - bifurcated terminals. Copper side view
66 Series - Power relays 30 A Features 66.22 66.82 2 Pole Changeover (DPDT) 30 A Power relay 66.22 PCB connections & mount 66.82 Faston 250 connections - Flange mount Reinforced insulation between coil
More information40 Series - Miniature P.C.B. Relays A
..4..4..4 40 Series - Miniature P.C.B. Relays 8-0 - 6 A - P.C.B. or plug-in mount - AC, DC, sensitive DC or single bistable coil versions available - 8 mm, 6 kv (./0 µs) between coil and contacts - Ambient
More information38 Series - Relay interface modules A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More information38 Series - Relay interface modules A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More informationmm wide Low coil power PCB or 93 series sockets. Copper side view. 1 CO (SPDT) 6/10 250/400 1, /0.2/ (12/10) AgNi
34 Series - Slim electromechanical PCB relays 6 A Features 34.51 Ultra-slim 1 Pole - 6 A relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw or screwless sockets 1 Pole
More information3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket
8-12 - 16 A Features 41.31 41.52 41.61 1 & 2 Pole - Low profile (15.7 mm height) 41.31-1 Pole 12 A (3.5 mm pin pitch) 41.52-2 Pole 8 A (5 mm pin pitch) 41.61-1 Pole 16 A (5 mm pin pitch) PCB mount - direct
More informationThe power in relays and timers since Catalogue
The power in relays and timers since 1954 2012 Catalogue PCB relays Industrial relays Relay interface modules Sockets and accessories Timers Monitoring relays Energy meters Surge protection devices Industrial
More information38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More informationA rated contacts Flange mount/faston 250 (6.3 x 0.8 mm) connection
65 Power relays 20-30 65 20 Power relays 1 NO + 1 NC (SPST-NO + SPST-NC) 65.31 Flange mount Faston 250 connections 65.61 PCB mount C coils & DC coils Cadmium Free option available 65.31 65.61 20 rated
More information38 Series - Relay Interface Modules A
Series - Relay Interface Modules 0.1-2 - 6 A - Relay interface modules for use with PLC systems, mm wide - Sensitive DC coil or AC/DC coil version - Supplied with integral coil - Instant removal of relay
More information3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket
41 Low profile PCB relays 8-12 - 16 41 1 & 2 Pole - Low profile (15.7 mm height) 41.31-1 Pole 12 (3.5 mm pin pitch) 41.52-2 Pole 8 (5 mm pin pitch) 41.61-1 Pole 16 (5 mm pin pitch) PCB mount - direct or
More informationMasterINTERFACE 39 Series - Relay interface modules
Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic clip Dual screw head (blade+cross)
More information2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1
Features 7S.12...5110 7S.14...0220/0310 7S.16..0420 Relay module with forcibly guided contacts 7S.12 with 2 pole (1NO + 1 NC) 7S.14 with 4 pole (2 NO + 2 NC and 3 NO + 1 NC) 7S.16 with 6 pole (4 NO + 2
More informationA rated contacts PCB mount - bifurcated terminals. Copper side view
66 Power relays 30 66 2 Pole Changeover (DPDT) 30 Power relay 66.22 PCB connections & mount 66.82 Faston 250 connections - Flange mount Reinforced insulation between coil and contacts according to EN 60335-1;
More informationMasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
More information83 Series - Modular timers 16 A. Features
Features 83 Series - Modular timers 16 A 83.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 83.11 - delay, multi-voltage 22.5 mm wide Six time scales from 0.1s to 20h High
More informationRelè di potenza 30 A SЕRIES. Power. generators. Industrial washing machines. Burners, boilers and furnaces. Industrial furnaces and ovens
66 SЕRIES Relè di potenza 30 Power generators Industrial washing machines Burners, boilers and furnaces Industrial furnaces and ovens ir conditioners Hoists and cranes Back-up generators Industrial motors
More informationMulti-voltage Multi-function. Wiring diagram (without control signal)
80 Modular timers 16 A 80 Multi-function and mono-function timer range 80.01T - Multi-function & multi-voltage 80.11T - On-delay, multi-voltage Complies with EN 45545-2:2013 (protection against fire of
More informationMulti-function 11 pin Plug-in for use with 90 series sockets
88 88 Multi-voltage and multi-function timer range Front panel or socket mount 8 and 11 pin plug-in versions available Time scales from 0.05 s to 100 h 1 delayed contact +1 instantaneous contact version
More informationRelays, Timers, Interface Modules, Sockets and Accessories Catalogue. The power in relays and timers since 1954
Relays, imers, Interface Modules, Sockets and Accessories. 003-004 Catalogue he power in relays and timers since 954 he power in relays ISO 900 ISO 400 Our four factories produce over 50,000 relays every
More information83 SERIES. 83 Series - Modular timers A. Features
Features 83 Series - Modular timers 12-16 A 83.01 83.02 83 Multi-function timer range 83.01 - Multi-function & multi-voltage, 1 Pole 83.02 - Multi-function & multi-voltage, 2 Pole (timed + instantaneous
More informationStep relays 10 A SЕRIES. Lighting control in corridors (for hotels, offices and hospitals) Bedroom light control. Living room light control
Lighting control in corridors (for hotels, offices and hospitals) Bedroom light control Living room light control SЕRIES FINDER reserves the right to alter characteristics at any time without notice. FINDER
More informationModular step relays 16 A
Automation for blinds, grilles and shutters Lighting control in corridors (for hotels, offices and hospitals) Bedroom light control Living room light control SЕRIES FINDER reserves the right to alter characteristics
More informationRelays, imers, Interface Modules, Sockets and Accessories. 003-004 Catalogue he power EL: in 0755-83376489 relays and timers since 954 E-MAIL: E-MAIL: he power in relays ISO 900 ISO 400 Our four factories
More informationModular timers A
Modular timers 1-6 - 8-16 A Building automation Elevators and lifts 80 SЕRIES Automation for blinds, grilles and shutters oists and cranes Panels for electrical distribution Door and gate openers FINDER
More informationMulti-function 11 pin Plug-in for use with 90 series sockets
88 eries - lug-in timers 5-8 A Features 88.02 88.12 Multi-voltage and multi-function timer range Front panel or socket mount 8-11 pin plug-in version available ime scales from 0.05s to 100h 1 delayed contact
More information46 SERIES. Fast, Reliable and Secure Connections. Miniature industrial relays. The power in relays and timers since 1954
SERIES Fast, Reliable and Secure Connections Miniature industrial relays The power in relays and timers since 9 Series - Miniature industrial relays, - A Features & Pole relay range. - Pole A. - Pole A
More informationMulti-voltage Multi-function. BE: Off-delay with control signal BE: Off-delay with control signal CE: On- and off-delay with control signal
83 Modular timers 12-16 A 83 Multi-function timer range 83.01 - Multi-function & multi-voltage, 1 Pole 83.02 - Multi-function & multi-voltage, 2 Pole (timed + instantaneous options), external time setting
More informationMulti-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi
Features Special relay for alternating loads, for applications with pumps, compressors, air conditioning or refrigeration units 2 independent NO output, 12 A 4 functions 2 independent control signals,
More informationRelays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:
RU Series Universal Relays Key features: Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator
More information87 Series - Modular timers 5-8 A. Features
87 eries - Modular timers 5-8 A Features 87.01 87.02 Mono-function and multi-function timer range mm wide 87.01-1 Pole - Multi-function and multi-voltage 87.02-2 Pole - Multi-function and multi-voltage,
More informationFixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits
Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay
More informationSMARTimer, digital timer 16 A
SMARTimer, digital timer 16 A Timers and lighting controls Automatic car-washes 84 SЕRIES Labelling machines Punches, cleaners, planers and sanders Industrial furnaces and ovens Discotheques, swimming
More informationFixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits
Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay
More information05/09/2014
48 x 48 Digital LCD Timer 814 Part number 88857005 Relay output digital timers LCD or LED (815E) Multi-range Multi-voltage 1 or 2 relay outputs Reset function on panel (Timers 815, 815E) Data saved in
More informationRelay systems. Interface Relay Compact IRC, Multifunction Timing Relay MFR IRC
Interface Relay Compact IRC, Multifunction Timing Relay MFR IRC IRC relay couplers and MFR-IRCP timing relays embody a new strategy for 6.2 mm coupling relays. Our five different relay versions provide
More information77 Series - Modular Solid State Relay 5 A. Features. Timers and Monitoring relays
Series - Modular Solid State Relay 5 A 77 Features 77.01.x.xxx.8050 77.01.x.xxx.8051 5 A modular SSR, 1 NO output 17.5 mm housing 60 to 240 V AC output (with back to back SCR) 5 kv (1.2/50 μs) insulation
More informationSensitivity range ( ) kω adjustable Delay time (0.5s or 7s) switch selectable Emptying or filling functions switch selectable
Features 72.01 72.11 Level control relays for conductive liquids 72.01 - Adjustable sensitivity 72.11 - Fixed sensitivity Emptying or filling functions LED indicator Reinforced insulation (6 kv - 1.2/50
More information13 Series - Electronic step/monostable & call/reset relays 8-16 A. Features
13 Series - Electronic step/monostable & call/reset relays 8-16 A Features 13.01 13.12 13.01 - Quiet operating electronic step/ monostable relay 1 Pole output contact 13.12 - Call & Reset Relay 2 Pole
More informationCARREL-ELECTRADE LTD not just products... solutions!
FINDER S RANGE OF DIN MOUNTED TIMERS 80 & 83 SERIES MULTI-VOLTAGE & MULTI-FUNCTION CARREL-ELECTRADE LTD not just products... solutions! Proudly 100% New Zealand owned and operated Auckland 661 Great South
More information13 SERIES. Electronic step relays A
13 Electronic step relays 10-16 A 13 13.81 - Electronic step relay - Rail mount - 1 Pole 13.91 - Electronic step relay and timing step relay Switch box mount - 1 Pole Fixed time (10 minutes) timing function
More informationElectronic step, call/reset and monostable relays
Electronic step, call/reset and monostable relays W/C Call and reset switches for bathrooms Bathrooms lighting control Bedroom light control Living room light control Office lighting control SЕRIES FINDER
More informationDPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR
General-purpose Relay MY New model Versatile and Function-filled Miniature Power Relay for Sequence Control and Power Switching Applications Models with lockable test buttons now available. Many variations
More information13 Series - Electronic step relays A. Features SERIES
Series - Electronic step relays 10-16 A SERIES Features.81.91.81 - Electronic step relay - Rail mount - 1 Pole.91 - Electronic step relay and timing step relay Switch box mount - 1 Pole Fixed time (10
More informationCONTA-ELECTRONICS. Relay systems
CONTA-ELECTRONICS Relay technology continues to play a large role in the reliability of industrial control and automation solutions. Because of their thin design, relay couplers are suitable for use in
More informationModel Number Structure
General-purpose Relay MK-I/-S Electromechanical Relays Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks relatively large load currents despite small size. Long
More informationRU Series Universal Relays
Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal
More informationGeneral-purpose Relay
General-purpose Relay Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks relatively large load currents despite small size. Long life (minimum 0,000 electrical
More informationSensitivity range ( ) kω adjustable Delay time (0.5s or 7s) switch selectable Emptying or filling functions switch selectable
72 Series - Monitoring relays 16 A Features 72.01 72.11 Level control relays for conductive liquids 72.01 - Adjustable sensitivity 72.11 - Fixed sensitivity Emptying or filling functions LED indicator
More informationSensitivity range ( ) kω adjustable Delay time (0.5s or 7s) switch selectable Emptying or filling functions switch selectable
Features Level control relays for conductive liquids 72.01 - Adjustable sensitivity 72.11 - Fixed sensitivity Emptying or filling functions LED indicator Reinforced insulation (6 kv - 1.2/50 µs) between:
More informationOMRON MK-I / -S RELAY
Issued April 0 0 DATA SHEET OMRON MK-I / -S RELAY Based on OMRON Datasheet General-purpose Relay MK-I/-S 0 Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks
More informationTwo-way Action Test Button (Models with Lockable Test Button) For Momentary Operation
General Purpose Relays MKS Exceptionally Reliable General Purpose Relay now available with Lockable Test Button IEC Rating of A 0 V AC 0/0 Hz, General use 100,000 cycles. Mechanical indicator standard
More informationRated power VA (50 Hz)/W 0.6/ / / /0.3 Operating range V AC (50/60 Hz)
77 Modular Solid State Relay 5 A 77 5 A modular SSR, 1 NO AC output 17.5 mm housing 60 to 240 V AC output (with back to back SCR) 5 kv (1.2/50 µs) insulation between and Output Zero-crossing and random
More information40.4. Control Relays and Timers. Contents. D3PR/D3PF Series. General Purpose Plug-In Relays. Features. Standards and Certifications
Control Relays and Timers. D Series Relay Contents Description Page DPR/DPF Series................................ DPR/DPF Series................................ DPR/DPF Series Catalog Number Selection........................
More informationMK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure
General-purpose Relays MK-S (New Models) CSM_MK-S_DS_E 1 New Super MK Relays. Latching Lever Added to the Series. Same mounting and internal wiring as the previous Super MK Relays Built-in mechanical indicator
More informationMeasuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC
2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from
More informationTime switches 16 A NEON SЕRIES. Heating and cooling. Shop displays. Lighting for parks. Streetlights and car park lighting.
Heating and cooling NEON Shop displays Lighting for parks SЕRES Streetlights and car park lighting School bells FNDER reserves the right to alter characteristics at any time without notice. FNDER assumes
More information13 Series - Electronic step relays A. Features Residential applications
13 13 Series - Electronic step relays 10-16 A Features 13.81 13.91 13.81 - Electronic step relay - Rail mount - 1 Pole 13.91 - Electronic step relay and timing step relay Switch box mount - 1 Pole Fixed
More informationMechanical daily time switch. 35 mm rail (EN 60715) mount
SERES SERES Mechanical time switches - Daily time setting* - Weekly time setting**.01.11.31 Type.01 --Daily --1 CO 16 A --35.8 mm wide --35 mm rail mount Type.11 --Daily --1 O 16 A --17.5 mm wide --35
More information02/11/2015
35 mm - 1 Relay 8A OUR3 Part number 88867103 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external
More information3.4. Control Relays and Timers. Contents Description D5RR/D5RF Series... D7PR/D7PF Series. General Purpose Plug-In Relays
.4 D7 Series Relay Contents Description D1RR/D1RF Series......................... D2RR/D2RF Series......................... DRR/DRF Series......................... D4 Series................................
More informationNo-wear isolation of potentials in terminal block design
TERMOPTO Overview No-wear isolation of potentials in terminal block design Space saving solid-state relay with PUSH IN connection technology The TERMOPTO opto modules are characterised by a particularly
More informationCurrent monitoring relays CM-SRS.2 for single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationPower PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).
Power PCB Relay Subminiature 20 L x 9.90 W x 9.90 H mm (0.79 L x 0.39 W x 0.39 H in) Low power consumption (200 mw) Sealed construction permits automatic soldering and cleaning of the PC board High-capacity
More informationCurrent monitoring relays CM-SRS.1 for single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.1 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationCurrent monitoring relays CM-SRS.1 For single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.1 For single-phase AC/DC currents The CM-SRS.1 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent
More information27/04/2015
Modular Carril DIN 35 mm HIL Part number 84871120 Control of AC and DC currents Automatic recognition of AC/DC Measurement ranges from 2 ma to 10 A Choice between over and undercurrent True RMS measurement
More informationVoltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More information3.4. Control Relays and Timers. Contents Description. D2RR/D2RF Series. General Purpose Plug-In Relays. Features
Control Relays and Timers. D Series Relay Contents Description DRR/DRF Series......................... DRR/DRF Series Catalog Number Selection................ Product Selection....................... Accessories............................
More information02/11/2015
35 mm - 2 Relays 8A PL2R1 Part number 88867455 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external
More information05/09/2012
17.5 mm EMER8 Part number 88829198 Multifunction or mono-function Multi-range (7 ranges) Multi-voltage or single voltage Screw terminals LED status indicator (1 voltage present LED, 1 timer ON LED) Option
More informationRXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB
Characteristics interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB Main Range of product Series name Product or component type Device short name Contacts type and composition
More information46.61 Series, SPDT 16A. Part Number Price Coil Voltage
www.factorymation.com/relays 85 Miniature Ice Cube Relays Mechanical flag indicator shows contact status Momentary / Lockable test button AgNi contacts (Cadmium free) Operating temperature: 40 to 58 F
More information316 PHOENIX CONTACT. RIF-1 for miniature and solid-state relays Page 334. RIF-2 for industrial relays Page 342. RIF-3 for octal relays Page 346
314 PHOENIX CONTACT PHOENIX CONTACT 315 RIF-0 for miniature and solid-state relays Page 328 RIF-1 for miniature and solid-state relays Page 334 RIF-2 for industrial relays Page 342 RIF-3 for octal relays
More informationMiniature Power Relay MSR
V23061 PCB relay for DC voltage, neutral, monostable Features Used as a switching element for electrical separation between low-power control circuits and power load circuits With 8 mm clearance and creepage
More information* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationGeneral-purpose Relay
General-purpose Relay Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks relatively large load currents despite small size. Long life (minimum 0,000 electrical
More informationRelays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection
RY/RM Series Miniature Relays Key features: RY (A), RY (A), RM (A) General purpose miniature relays A or A contact capacity Wide variety of terminal styles and coil voltages meet a wide range of applications
More informationControls Contactors and Contactor Assemblies Special Applications
Controls Contactors and Contactor Assemblies Special Applications Price groups 1B, 1H /2 Introduction More information can be found on the Internet: see the opening information, page 13 - Contactors for
More informationThermistor motor protection relays
Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /
More informationCurrent monitoring relays CM-SRS.2 For single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent
More informationRelays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.
RFV Key features: Compact and EN compliant RFV force guided relays Force guided contact mechanism (EN00 Type A TÜV approved) Contact configuration -pole (NO-NC, 3NO-NC) 6-pole (NO-NC, NO-NC, 3NO-3NC) Built-in
More informationElectronic timer CT-SDS.22
CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication
More informationCurrent monitoring relays CM-SRS.M1 For single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents The CM-SRS.M1 is an electronic current monitoring relay that monitors single-phase mains (DC or AC) for over- and undercurrent
More informationRJ Series Slim Power Relays
RJ Series RJ Series Slim Relays Circuit Breakers Terminal Blocks Timers Display Lights Switches & Pilot Lights Compact and rugged power relays. Large switching capacity. Compact housing only.7-mm wide.
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More informationV DC 4 POLE RELAY RC V DC 4 POLE RELAY (RC) V AC 4 POLE RELAY
DT SHEET Plug-in power relays Order code Manufacturer code Description -.. V DC POLE RELY RC -.. V DC POLE RELY (RC) -.. V C POLE RELY Plug-in power relays The enclosed information is believed to be correct,
More informationVoltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages The CM-EFS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationThree-phase monitoring relays CM-PFE and CM-PFE.2
Data sheet Three-phase monitoring relays CM-PFE and CM-PFE.2 The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251
More information