1 MITEQ TECHNICAL NOTE 25T022 MARCH 2000 REV H LOCAL/REMOTE CONTROL and FUNCTIONAL DESCRIPTION UNIVERSAL Ku-BAND TEST TRANSLATOR UNIVERSAL DBS BAND TEST TRANSLATOR GENERAL DESCRIPTION The Universal Band Test Loop Translator (TLT) is a wideband single conversion translator. It is designed for applications where various transmit-to-receive translations are required. The translator is microprocessor controlled and soft-key menu driven for rapid set up and easy operation. Translator parameters are selected by choosing a satellite name or a combination of uplink, downlink and translation frequencies. The translator features a large back lit display, function keys and a scroll knob to provide instant access to operating parameters. All operating parameters are accessible locally or via the remote interface bus. Software upgrades and revisions to a library of satellites can be achieved through the use of PCMCIA memory card. FEATURES OPTIONS Local or remote control Minimum amplitude and delay distortion High frequency stability Low intermodulation distortion 30 db input level control Low phase noise contribution Summary alarm Complete control and monitoring capability over a remote bus (RS232, RS422, or IEEE-488). RS485 is standard. 60 db total input level control Higher frequency stability External 5 MHz reference 1

2 FRONT PANEL OPERATIONS The front panel display and indicators have been organized so that important information is available at a glance. The keyboard is divided into functional groups which allow an operator to easily change any parameter from the front panel. See Figure 1 for the physical layout of the front panel. KEYPAD OPERATION Figure 1. Front Panel, Universal Band Translator The keypad is divided into five functional groups (Power, Screen Select keys, Soft-keys, Data Entry and Local/Remote Select). The error tone will sound when an illegal key is pressed and in some cases, a warning message will be displayed. POWER The AC Power switch is located on the lower right of the front panel. To cycle power simply push this button. The push-button LED is lit when power is on. SCREEN SELECT KEYS The Screen Select keys are located to the right of the display area. They allow the operator to switch between the five screens with ease. By pressing one of the five screen select keys instant access to pertinent data is granted. The CNTRL key is operative in both Local and Remote modes. SOFT-KEYS The five Soft-keys, adjacent to the display, are labeled A through E. The context of these keys is screen dependent. A brief definition is presented, on the active screen, adjacent to the soft-keys. Pressing undefined soft-keys will cause an error tone to sound. DATA ENTRY The Data Entry keys, along with the scroll knob, allow the operator to enter specific data into an active field. Data is entered using the numbered keys or scroll knob then pressing the ENT key. Invalid entries will be ignored and cause an error tone to sound. While in Remote mode, local data entry is prohibited, however, all system parameters can be examined. 2

3 LOCAL/REMOTE SELECT The front panel REMOTE key selects either Local (LED off) or Remote mode (LED on). The mode alternates with each key press. On units equipped with the IEEE-488 remote option this key puts the unit into Local mode only as dictated by that standard. While in Local mode, translator settings can be changed using the front panel. All of the status information can be monitored over the remote bus. Remote attempts to alter the translator settings will be ignored. With translator settings under remote control, the system parameters can be observed locally. Efforts to alter the translator settings from the front panel, while in Remote mode, will be ignored and cause an error tone to sound. LCD DISPLAY The LCD display is TNT type with a cold cathode fluorescent tube backlight. The display automatically shuts off the back-light after 5 minutes of continuous operation without front panel input. ALARM STATUS If any alarms exist, a three second tone will sound every thirty seconds until the alarm is cleared. The LCD back-light will not automatically shut off after 5 minutes of non use while an alarm is present. The system power supply voltages out of range and the LO out-of-lock can cause an alarm. Alarm status can be examined in both Local and Remote modes on the System Monitor screen. SUMMARY ALARM A summary alarm condition exists while any alarm is present and will automatically be cleared when all components return to the normal condition. LOCAL OPERATION In Local mode, the translator is controlled from the front panel. System parameters can still be monitored over the remote bus, however, attempts to change settings remotely, while in Local mode, will be ignored. The five front panel Screen Select Keys are located to the right of the LCD display. These keys control the display and allow data entry into the various functional areas of the translator. The five soft-keys, labeled A through E, are context sensitive with respect to the current screen. There are five different screens, one for each Screen Select Key plus the default system monitor screen. The screens available are: System Monitor (default) Satellite Name Uplink Band Downlink Band Translation Frequency Control 3

4 SETTING THE TRANSLATOR CONFIGURATION FROM THE FRONT PANEL A TLT configuration is composed of three parameters. They are: input band, output band, and translation frequencies. The translator is equipped with a library of satellites which reside in nonvolatile memory. A specific configuration is associated with each satellite name in that library. The translator can be configured by simply selecting a satellite name from the library. Pressing a screen select key activates the appropriate screen. Once selected, a list of choices is displayed on the lower portion of the screen. The appropriate parameter for that screen is highlighted by reversed video on both the upper and lower portions of the screen and the title for that parameter on the upper portion of the screen starts flashing. Use the scroll knob to scroll through the list on the lower portion of the screen then press the ENT key to make the selection. The ENT key must be pressed within 60 seconds to select the highlighted entry and stop the flashing. Otherwise an error tone will sound and the screen will return to the current settings and default System Monitor Screen. The translator can also be configured be selecting each of the three individual elements; input band, output band, and translation frequency. The first parameter to be selected, will cause the satellite name and the remaining two parameters to clear. The uplink band, downlink band and translation frequency titles will all start flashing, indicating that all three parameters must be set before the translator can be set. As each parameter is set, its title stops flashing. When the last parameter is set, the translator will be set to the selected settings. If the unit is left idle for 60 seconds and at least one title is flashing, a time-out condition will arise causing the error tone to sound and the screen to return to the current settings and default System Monitor Screen. CUSTOM SATELLITE CONFIGURATIONS Up to eight (optionally more) custom configurations can be added to the library, each with a preassigned name CUSTOM0 through CUSTOM7. An alias name can also be assigned to each custom configuration by a remote command. The custom configurations can be recalled from memory using either its preassigned satellite name or its alias name. To add a custom satellite configuration to the list, select ADD A CUSTOM CONFIGURATION from the satellite name screen. A list of custom satellite names will be displayed on the bottom portion of the screen. Using the scroll knob, choose a name from the list and press the ENT key. Now set the uplink band, downlink band and translation frequency. When all four entries are complete; the satellite name, uplink band, downlink band and translation frequency, the custom configuration will be added to the top of the current satellite list and the translator will be configured to these settings. To edit a custom configuration in the list, select EDIT A CUSTOM CONFIGURATION from the satellite name screen. A list of custom satellite names will be displayed on the bottom portion of the screen. Using the scroll knob, choose a name from the list and press the ENT key. Now set the uplink band, downlink band and translation frequency. When all four entries are complete; the satellite name, uplink band, downlink band and translation frequency, the custom satellite configuration will be changed and the translator will be configured to these settings. 4

5 SYSTEM MONITOR SCREEN The System Monitor Screen displays the satellite name, uplink band, downlink band, translation frequency and input attenuation value. The system DC voltages, phase voltage and alarms are also displayed for monitoring purposes. This screen is the default screen. 5

6 SATELLITE NAME SCREEN The Satellite Name Screen displays the names of the satellites stored in the library. Pressing the SAT NAME screen select key activates this screen. The current selected satellite is displayed at the top of the screen along with the specific configuration currently selected. The satellite name at the top of the screen and in the satellite list is highlighted by reversed video. Selecting a satellite by name can be accomplished by scrolling through the list until the desired satellite is highlighted and then pressing the ENT key. The uplink band, downlink band, and translation frequency are updated as the list is traversed with the scroll knob to aid in the selection of a satellite (some satellites have multiple configurations). 6

7 UPLINK BAND SCREEN The Uplink Band Screen displays a list of the available uplink bands. Pressing the UPLINK screen select key activates this screen. The uplink band at the top of the screen and in the uplink band list is highlighted by reversed video. Select an uplink band by scrolling through the list until the desired uplink band is highlighted and then press the ENT key. If the downlink band and/or the translation frequency have been previously selected, the list of available uplink bands will be limited by those selections that match the list of satellites currently stored in the library. If the desired uplink band cannot be found in the list of available uplink bands, a band can be manually entered using the data entry keys. First enter the uplink band lower limit in GHz using the number keys and decimal point followed by the ENT key. Next enter the uplink band upper limit in GHz using the number keys and decimal point followed by the ENT key. An illegal range will cause the error tone to sound. Valid uplink bands are GHz and GHz for Ku Band and GHz and GHz for DBS Band. If the downlink band and/or translation frequency have not yet been selected, make these selections now by pressing either the DNLINK or XLATN Screen Select Key. 7

8 DOWNLINK BAND SCREEN The Downlink Band Screen displays a list of the available downlink bands. Pressing the DNLINK screen select key activates this screen. The downlink band at the top of the screen and in the downlink band list is highlighted by reversed video. Select a downlink band by scrolling through the list until the desired downlink band is highlighted and then press the ENT key. If the uplink band and/or the translation frequency have been previously selected, the list of available downlink bands will be limited by those selections to match the list of satellites currently stored in the library. If the desired downlink band cannot be found in the list of available downlink bands, a band can be manually entered using the data entry keys. First enter the downlink band lower limit in GHz using the number keys and decimal point followed by the ENT key. Next enter the downlink band upper limit in GHz using the number keys and decimal point followed by the ENT key. An illegal range will cause the error tone to sound. Valid downlink bands are GHz, GHz and GHz for Ku Band and GHz, GHz and GHz for DBS Band. If the uplink band and/or translation frequency have not yet been selected, make these selections now by pressing either the UPLINK or XLATN Screen Select Key. 8

9 TRANSLATION FREQUENCY SCREEN The Translation Frequency Screen displays a list of the available translation frequencies. Pressing the XLATN screen select key activates this screen. The translation frequency at the top of the screen and in the translation frequency list is highlighted by reversed video. Select a translation frequency by scrolling through the list until the desired translation frequency is highlighted and then press the ENT key. Choose the EXTERNAL entry in the list if an external LO is to be used as the translation frequency. If the uplink band and/or the downlink band have been previously selected, the list of available translation frequencies will be limited by those selections to match the list of satellites currently stored in library. If the desired translation frequency cannot be found in the list of available translation frequencies, a frequency can be manually entered using the data entry keys. Enter the translation frequency in GHz using the number keys and decimal point followed by the ENT key. An illegal frequency will cause the error tone to sound. Valid translation frequencies are GHz for Ku Band and GHz for DBS Band. If the uplink band and/or downlink band have not yet been selected, make these selections now by pressing either the UPLINK or DNLINK Screen Select Key. 9

10 CONTROL SCREEN The Control Screen provides access to various system parameters. Press the CNTRL screen select key to activate this screen. The soft-keys give simple access to the system parameters outlined below. The system attenuation level and the RF mute can both be accessed with the "A" soft-key. System attenuation level can be varied by controlling the applied attenuation. Press the A softkey until the attenuation parameter is highlighted by reversed video. Then use the data entry keys followed by ENT or the scroll knob to achieve the desired system gain. When a data entry key is pressed, the attenuation parameter starts flashing. The ENT key must be pressed within 60 seconds to select the entry and stop the flashing. Otherwise an error tone will sound and the parameter will return to the current setting. The RF mute can also be controlled by using the "A" soft-key. Press the "A" soft-key until the RF mute parameter is highlighted by reversed video. Use the scroll knob to toggle between enabled and disabled. Then press "ENT". The ENT key must be pressed within 60 seconds to select the entry and stop the flashing. Otherwise an error tone will sound and the parameter will return to the current setting. 10

11 The remote control parameters can be accessed by pressing the B through D soft-keys from the control screen. To modify particular parameters press the appropriate soft-key to activate that field. The selected parameter will be highlighted by reversed video. Scroll through the possible selections until the desired setting is displayed. When the scroll knob is turned, the title for that parameter starts flashing. Once the scroll knob is then left idle, the ENT key must be pressed within 60 seconds to select the entry and stop the flashing. Otherwise an error tone will sound and the parameter will return to the current setting. For the RS485, RS422 and RS232 serial interfaces the fields are: Soft-key B - Device Address (64-95) Soft-key C - Baud Rate Soft-key D - Parity Odd Even None For the IEEE-488 interface the fields are: Soft-key B - Device Address (00-30) Soft-key C - SRQ Enabled Disabled If necessary, the contrast and viewing angle of the LCD may be adjusted by pressing the E softkey then turning the scroll knob until the preferred setting is obtained. SOFTWARE REVISION The Software Revision level that is currently installed can be viewed on the Control Screen. This revision number is displayed as n.nn.t. Where n.nn is the revision of the Software and.t. is the revision of the Satellite Table. A revision of 1.01.F would indicate a Software revision of 1.01 and a Satellite Table revision of F. A new release could include a Software revision update, a Satellite Table revision or both. Refer to MITEQ Technote 25T016 for a typical Satellite Table. The Software and/or Satellite Table can be updated with a memory card available from MITEQ. 11

12 MODEL The Model Number of the software that is currently installed can be viewed on the Control Screen. SOFTWARE UPDATES The list of supported satellites and/or software enhancements can be brought up to date with a memory card. To update simply turn the translator off, insert the memory card into the slot and turn the translator back on. Press the A soft-key to update or the B soft-key to not update. If there is no user input for one minute, the system will automatically choose the B option which will skip the update and start the software that is currently loaded. When the update is complete, the unit will begin normal operation and the card should be removed. Custom configurations will not be changed by software updates. REMOTE OPERATION The translator is supplied with an RS485 bus interface or, as an option, can be supplied with RS232, RS422 or IEEE-488. The command structures for the first three buses, which are serial, are identical. The IEEE-488 format is similar with the exception that no header, trailer or checksum bytes are included in the structures. RS232/422/485 REMOTE PROTOCOL The command structures for the serial buses; RS232, RS422 and RS485 are identical. All transmissions are multi-byte sequences beginning with a header byte, and ending with a trailer byte and checksum byte. The transmitted bytes are all ASCII printable characters in the range of 20H to 7EH. Serial data format is a 10 bit sequence consisting of one start, 7 or 8 data, 1 or no parity, and 1 stop bit. All characters, including the checksum character, are checked for parity unless the NONE parity option is selected. If any character in a command message contains an error (parity, framing or overrun) or the checksum is incorrect, the command is ignored and no response is made. The remote parameters; Address, Baud Rate, and Parity are programmable from the front panel. The response time from command to acknowledge is 100 ms. maximum. All messages addressed to the translator are acknowledged with a response message. The translator continually monitors the communication bus and will accept commands addressed to it, even in Local mode. When in Local mode, receipt of any SET commands (commands beginning with $ ) will be ignored, and the translator will respond with an error code. 12

13 DEVICE ADDRESS/BAUD RATE/PARITY SELECTION The remote control parameters can be accessed by pressing the B, C and D soft-keys from the control screen. To change the device address press the B soft-key, scroll through the possible addresses (64-95) until the desired address is displayed, and press the ENT key or press the B soft key again to retain the former address. To set the baud rate press the C soft-key, scroll through ( ) until the desired baud rate is displayed, and press the ENT key or press the C soft key again to retain the former baud rate. To select the parity press the D soft-key, scroll through odd, even or none and press the ENT key or press the D soft key again to retain the former parity. MESSAGE FORMAT The message format is as follows: HEADER - TRANSLATOR ADDRESS - COMMAND/ERROR CODE - PARAMETERS - TRAILER - CHECKSUM The response time from command to acknowledge is 100 ms. maximum. HEADER BYTE The Header byte is 7BH, ASCII character "{". TRANSLATOR ADDRESS The translator may take on the address values from 64 to 95 (40H to 5FH). COMMAND CODE SUMMARY COMMAND CODES ASCII Character String NAM FRQ ATT ALR STA CUS MUT Function Satellite Name Satellite Frequencies Attenuation Alarm Status Status All Custom Satellite Alias Name RF Mute 13

14 ERROR CODE SUMMARY PARAMETERS ASCII Character Function a Command not recognized b Illegal parameter or out of range c Translator in Local mode d Translator busy Parameters are all ASCII printable characters in the range of 20H to 7EH. Numeric parameters are sent MSD first, LSD last. Values which do not adhere to the command format, or are beyond the allowable range, will be rejected and cause the translator to respond with an error code. TRAILER BYTE The Trailer byte is 7DH, ASCII character "}". CHECKSUM BYTE The checksum byte is the sum modulo 95 of all message characters beginning with the header byte up to and including the trailer byte. The value 32 is subtracted from each character value before taking the modulo 95 sum. The value 32 is added to the final sum to obtain the checksum value. All values are in decimal. Below is a program, written in the C programming language that illustrates the checksum calculation. Checksum = MOD [(character value - 32), 95] + 32 /* return the checksum character for the message in array subtract 32 from each character before taking modulo 95 sum add 32 to the final sum mes_len = message length */ char check_sum(char *array, char mes_len) { char i,sum; for (i = 0, sum = 0; i < mes_len; i++) { sum += *array ; sum %= 95; } return(sum + 32); } 14

15 COMMAND CODE DESCRIPTION The following paragraphs describe each of the command codes. For clarity the header, address, trailer and checksum characters are not shown. Upper case letters are the actual command or response characters. Lower case letters represent parameter character strings. Commands preceded by? are QUERY commands and those preceded by $ are SET commands. QUERY commands are used to examine system parameters remotely while SET commands are intended to modify system parameters. SATELLITE NAME = NAM The SET command has two forms. The first form specifies a satellite name only. The second form species a satellite name and frequency. A satellite name may appear more than once in the satellite tables. The only difference between these entries is the frequency associated with that name. When a satellite name appears in the list more than once, the first form of this command will select the first match found to that satellite name. The second form of this command can select any satellite in the list. Name Only Specified: The SET command requires that the name of the satellite be included as a parameter. Up to thirty characters are allowed for a satellite name. Names shorter than 30 characters are allowed. Embedded spaces are allowed. Trailing spaces are optional. Custom satellite names, custom satellite alias names as well as library satellite names can be used to select a satellite. Duplicate satellite names can exist in the satellite library and also in the custom satellite alias list. The search starts with the custom satellite list followed by the custom satellite alias list and finally the library satellite list. The first match found in this ordered search will be chosen. Name and Frequency Specified: The SET command requires a 30 character name and a frequency specification. The name must be 30 characters long. If the satellite name is less than 30 characters in length, trailing spaces must be appended to the name so that the total length of the name is 30 characters. Following the name is the ASCII string "FRQU" followed by two five digit parameters separated by an ASCII - for the uplink band, an ASCII D followed by two five digit parameters separated by an ASCII - for the downlink band, and an ASCII X followed by a seven digit parameter or the character string EXTERNAL for the translation frequency. Remote Command Sequence: $NAMnnnnn...nnnnn or $NAMnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnFRQUlllll-hhhhhDlllll-hhhhhXfffffff Response: $NAM nnnnn...nnnnn: 1-30 character name. nnnnnnnnnnnnnnnnnnnnnnnnnnnnnn: 30 character name. lllll: Five digit low band edge frequency expressed in MHz. hhhhh: Five digit high band edge frequency expressed in MHz. fffffff: Seven digit translation frequency expressed in khz or the character string EXTERNAL if the translation frequency is supplied externally. 15

16 The QUERY command requires no parameters. Remote Command Sequence:?NAM Response:?NAMnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnnnnnnnnnnnnnnnnnnnnnnnnnnnnn: 30 character satellite name. SATELLITE FREQUCNCIES = FRQ The SET command requires an ASCII U followed by two five digit parameters separated by an ASCII - for the uplink band, an ASCII D followed by two five digit parameters separated by an ASCII - for the downlink band, and an ASCII X followed by a seven digit parameter or the character string EXTERNAL for the translation frequency. Remote Command Sequence: $FRQUlllll-hhhhhDlllll-hhhhhXfffffff Response: $FRQ The QUERY command requires no parameters. Remote Command Sequence:?FRQ Response:?FRQUlllll-hhhhhDlllll-hhhhhXfffffff lllll: Five digit low band edge frequency expressed in MHz. hhhhh: Five digit high band edge frequency expressed in MHz. fffffff: Seven digit translation frequency expressed in khz or the character string EXTERNAL if the translation frequency is supplied externally. ATTENUATION = ATT The SET command requires a three digit parameter which sets the attenuation of the translator in 0.2 db steps. The parameter is expressed in tenths of a db so no decimal point is required. Remote Command Sequence: $ATTttt Response: $ATT The QUERY command requires no parameters. Remote Command Sequence:?ATT Response:?ATTttt ttt: Attenuation in tenths of a db. ALARM STATUS = ALR There is no SET command. The QUERY command requires no parameters. Remote Command Sequence:?ALR Response:?ALRabcd 16

17 a through d are ASCII 0 or 1 and represent the fault alarms below. a: LO Alarm b: Power Supply Alarm c: not assigned d: not assigned STATUS ALL = STA 0 = No fault, 1 = Fault There is no SET command. The QUERY command requires no parameters. The response is a combination of the?nam,?frq,?att and?alr commands. Remote Command Sequence:?STA Response:?STANAMnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnFRQUlllll-hhhhhDlllll-hhhhhXfffffffATTtttALRabcd nnnnnnnnnnnnnnnnnnnnnnnnnnnnnn: 30 character name. lllll: Five digit low band edge frequency expressed in MHz. hhhhh: Five digit high band edge frequency expressed in MHz. fffffff: Seven digit translation frequency expressed in khz or the character string EXTERNAL if the translation frequency is supplied externally. ttt: Attenuation in tenths of a db. a through d are ASCII 0 or 1 and represent the fault alarms. CUSTOM SATELLITE ALIAS NAME = CUS The SET command requires a one or two digit parameter that specifies the CUSTOM satellite number to which the alias name will be assigned, and a second parameter that specifies the alias name of the custom satellite. Up to thirty characters are allowed for a custom satellite alias name. Embedded spaces are allowed. Trailing spaces are optional. Remote Command Sequence: $CUSc(c)Nnnnnn...nnnnn c(c) = One or Two digit custom satellite number N = Name indicator nnnnn...nnnnn: 1-30 character name. Response: $CUS 17

18 The QUERY command requires a one or two digit parameter that specifies the CUSTOM satellite number. Remote Command Sequence:?CUSc(c) Response:?CUSc(c)Nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn c(c) = One or Two digit custom satellite number N = Name indicator nnnnnnnnnnnnnnnnnnnnnnnnnnnnnn: 30 character alias satellite name SATELLITE TABLE = SAT There is no SET command. The QUERY command requires a four-digit parameter indicating the satellite table entry to be examined. If entry 0000 is selected, the unit returns the number of satellites in the table. Otherwise the unit responds with the satellite name and frequency specification. MUTE = MUT Remote Command Sequence:?SATssss Response:?SATtttt or?satnamnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnfrqulllll-hhhhhdlllll-hhhhhxfffffff ssss: Satellite number tttt: Total number of satellites in the table. nnnnnnnnnnnnnnnnnnnnnnnnnnnnnn: 30 character name. lllll: Five digit low band edge frequency expressed in MHz. hhhhh: Five digit high band edge frequency expressed in MHz. fffffff: Seven digit translation frequency expressed in khz or the character string EXTERNAL if the translation frequency is supplied externally. The SET command requires a single parameter which sets the mute status. Remote Command Sequence: $MUTm Response: $MUT The QUERY command requires no parameters. Remote Command Sequence:?MUT Response:?MUTm m: 0 = RF not muted 1 = RF muted 18

19 19

20 COMMAND EXAMPLES With a translator set for address 41H (ASCII code A ) the following are typical commands to and responses from the translator. A. Set the attenuation to 24.6 db. Controller Command Translator Response {A$ATT246}F {A$ATT}i B. Check the alarms. The translator indicates a power supply alarm. Controller Command Translator Response {A?ALR}z {A?ALR1000}l RS422/485 BUS TERMINATION A jumper selectable 120 ohm termination may be placed across the Data terminals. Placing a jumper across E1 connects the resistor between the DATA OUT + and - terminals. E2 connects the resistor between the DATA IN + and - terminals. E1 and E2 are on the main control PC board inside the translator. RS232 RTS/CTS (Option 17C Only) When the translator is equipped with an RS232 remote bus interface, the RTS output and CTS input signals are internally connected together with a jumper plug. The jumper must be removed if it is necessary to use the RTS/CTS protocol. The jumper is located on the auxiliary PC board which is mounted onto the main control PC board. IEEE-488 REMOTE CONTROL The translator performs the basic Talker and Listener functions as specified in the IEEE-488 standard. It is also capable of sending a Service Request to the active IEEE-488 Controller and will respond with a status word when the Serial Poll Enable message is received. The messages to and from the translator are ASCII character strings terminated with CR, LF and EOI. The response time from command to acknowledge is 100 ms maximum. DEVICE ADDRESS/SERVICE REQUEST ENABLE SELECTION The remote control parameters can be accessed by pressing the B and C soft-keys from the control screen. To change the device address, press the B soft-key, scroll through the possible addresses (00-30) until the desired address is displayed, and press the ENT key or press the B soft key again to retain the former address. 20

21 To enable/disable the SRQ, press the C soft-key, use the scroll knob to toggle between service request enabled and disabled. Press the ENT key when the desired setting is displayed or press the C soft key again to retain the former setting. MESSAGE PROTOCOL The following paragraphs describe each of the command codes. Commands preceded by? are QUERY commands and those preceded by $ are SET commands. QUERY commands are used to examine system parameters remotely while SET commands are intended to modify system parameters. SET commands do not affect the translator s response when it is addressed to talk by the IEEE-488 Controller. QUERY commands determine the translator s response when it is addressed to talk by the IEEE-488 Controller. The context of the translator s response remains in effect until another QUERY command is received. The alarm QUERY command (?ALR) is in effect at power up as the default response. SATELLITE NAME = NAM The SET command has two forms. The first form specifies a satellite name only. The second form species a satellite name and frequency. A satellite name may appear more than once in the satellite tables. The only difference between these entries is the frequency associated with that name. When a satellite name appears in the list more than once, the first form of this command will select the first match found to that satellite name. The second form of this command can select any satellite in the list. Name Only Specified: The SET command requires that the name of the satellite be included as a parameter. Up to thirty characters are allowed for a satellite name. Names shorter than 30 characters are allowed. Embedded spaces are allowed. Trailing spaces are optional. Custom satellite names, custom satellite alias names as well as library satellite names can be used to select a satellite. Duplicate satellite names can exist in the satellite library and also in the custom satellite alias list. The search starts with the custom satellite list followed by the custom satellite alias list and finally the library satellite list. The first match found in this ordered search will be chosen. Name and Frequency Specified: The SET command requires a 30 character name and a frequency specification. The name must be 30 characters long. If the satellite name is less than 30 characters in length, trailing spaces must be appended to the name so that the total length of the name is 30 characters. Following the name is the ASCII string "FRQU" followed by two five digit parameters separated by an ASCII - for the uplink band, an ASCII D followed by two five digit parameters separated by an ASCII - for the downlink band, and an ASCII X followed by a seven digit parameter or the character string EXTERNAL for the translation frequency. 21

22 Remote Command Sequence: $NAMnnnnn...nnnnn or $NAMnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnFRQUlllll-hhhhhDlllll-hhhhhXfffffff nnnnn...nnnnn: 1-30 character name. nnnnnnnnnnnnnnnnnnnnnnnnnnnnnn: 30 character name. lllll: Five digit low band edge frequency expressed in MHz. hhhhh: Five digit high band edge frequency expressed in MHz. fffffff: Seven digit translation frequency expressed in khz or the character string EXTERNAL if the translation frequency is supplied externally. The QUERY command requires no parameters. Remote Command Sequence:?NAM Response when addressed as a talker:?namnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnnnnnnnnnnnnnnnnnnnnnnnnnnnnn: 30 character satellite name. SATELLITE FREQUCNCIES = FRQ The SET command requires an ASCII U followed by two five digit parameters separated by an ASCII - for the uplink band, an ASCII D followed by two five digit parameters separated by an ASCII - for the downlink band, and an ASCII X followed by a seven digit parameter or the character string EXTERNAL for the translation frequency. Remote Command Sequence: $FRQUlllll-hhhhhDlllll-hhhhhXfffffff The QUERY command requires no parameters. Remote Command Sequence:?FRQ Response when addressed as a talker:?frqulllll-hhhhhdlllll-hhhhhxfffffff lllll: Five digit low band edge frequency expressed in MHz. hhhhh: Five digit high band edge frequency expressed in MHz. fffffff: Seven digit translation frequency expressed in khz or the character string EXTERNAL if the translation frequency is supplied externally. ATTENUATION = ATT The SET command requires a three digit parameter which sets the attenuation of the translator in 0.2 db steps. The parameter is expressed in tenths of a db so no decimal point is required. Remote Command Sequence: $ATTttt 22

23 The QUERY command requires no parameters. Remote Command Sequence:?ATT Response when addressed as a talker:?attttt ttt: Attenuation in tenths of a db. ALARM STATUS = ALR There is no SET command. The QUERY command requires no parameters. Remote Command Sequence:?ALR Response when addressed as a talker:?alrabcd a through d are ASCII 0 or 1 and represent the fault alarms below. a: LO Alarm b: Power Supply Alarm c: not assigned d: not assigned 0 = No fault, 1 = Fault STATUS ALL = STA There is no SET command. The QUERY command requires no parameters. The response is a combination of the?nam,?frq,?att and?alr commands. Remote Command Sequence:?STA Response when addressed as a talker:?stanamnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnfrqulllll-hhhhhdlllll-hhhhhxfffffffatttttalrabcd nnnnnnnnnnnnnnnnnnnnnnnnnnnnnn: 30 character name. lllll: Five digit low band edge frequency expressed in MHz. hhhhh: Five digit high band edge frequency expressed in MHz. fffffff: Seven digit translation frequency expressed in khz or the character string EXTERNAL if the translation frequency is supplied externally. ttt: Attenuation in tenths of a db. a through d are ASCII 0 or 1 and represent the fault alarms. 23

24 CUSTOM SATELLITE ALIAS NAME = CUS The SET command requires a one or two digit parameter that specifies the CUSTOM satellite number to which the alias name will be assigned, and a second parameter that specifies the alias name of the custom satellite. Up to thirty characters are allowed for a custom satellite alias name. Embedded spaces are allowed. Trailing spaces are optional. Remote Command Sequence: $CUSc(c)Nnnnnn...nnnnn c(c) = One or Two digit custom satellite number N = Name indicator nnnnn...nnnnn: 1-30 character name. The QUERY command requires a one or two digit parameter that specifies the CUSTOM satellite number. Remote Command Sequence:?CUSc(c) Response when addressed as a talker:?cusc(c)nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn c(c) = One or Two digit custom satellite number N = Name indicator nnnnnnnnnnnnnnnnnnnnnnnnnnnnnn: 30 character alias satellite name SATELLITE TABLE = SAT There is no SET command. The QUERY command requires a four-digit parameter indicating the satellite table entry to be examined. If entry 0000 is selected, the unit returns the number of satellites in the table. Otherwise the unit responds with the satellite name and frequency specification. Remote Command Sequence:?SATssss Response when addressed as a talker:?sattttt or?satnamnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnfrqulllll-hhhhhdlllll-hhhhhxfffffff ssss: Satellite number tttt: Total number of satellites in the table. nnnnnnnnnnnnnnnnnnnnnnnnnnnnnn: 30 character name. lllll: Five digit low band edge frequency expressed in MHz. hhhhh: Five digit high band edge frequency expressed in MHz. fffffff: Seven digit translation frequency expressed in khz or the character string EXTERNAL if the translation frequency is supplied externally. 24

25 SERVICE REQUEST The translator will issue a service request (activate the SRQ line) if the SRQ is enabled and one of the status alarms indicate a failure. The IEEE-488 Controller then performs a serial poll addressing the unit to talk. The following bits are reported back to the controller: Bit Number d c b a a through d are 0 or 1 and represent the fault alarms below. a: LO Alarm b: Power Supply Alarm c: not assigned d: not assigned 0 = No fault 1 = Fault The IEEE-488 Controller may perform a serial poll without a service request being generated by the translator (a request may have been generated by another device on the bus). In this case, the message will have the same format with the exception that bit 6 will be a 0. REMOTE INTERFACE CONNECTION The remote interface connector(s) is located on the rear panel of the translator. The approximate location(s) is depicted in Figure 2. Figure 2. Universal Band Translator Rear Panel Diagram 25

26 RS422/485 REAR PANEL INTERFACE CONNECTOR J6 and J10 Pin Signal 1 Ground 3 Data Out - 5 Data In - 7 Data Out + 9 Data In + Note: For RS485 two wire party line operation Data In + must be externally wired to Data Out +, and Data In - must be externally wired to Data Out -. RS232 REAR PANEL INTERFACE CONNECTOR J6 Pin Signal 1 Ground 2 TX Data 3 RCV Data 7 Ground IEEE-488 REAR PANEL INTERFACE CONNECTOR IEEE-488 compatible contact connector (receptacle). SUMMARY ALARM CONNECTOR The summary connector, located on the rear panel, provides the status of the translator s alarm functions via a contact closure interface. The summary alarm connector pin designations are as follows: 1. DC Power Status - a. Normal: Pins 1-2 open,2-3 closed b. Fault: Pins 1-2 closed, 2-3 open 2. Summary Alarm Status - a. Normal (No Alarms): Pins 4-5 open,5-6 closed b. Fault (Any Alarm): Pins 4-5 closed, 5-6 open 26

27 REDUNDANCY SWITCH CONNECTOR The redundancy switch connector, located on the rear panel, provides a summary alarm output via a contact closure interface. This can be used in conjunction with a Redundancy Switchover Unit. The redundancy switch connector pin designations are as follows: 1. Summary Alarm Status - a. Normal (No Alarms): Pins 1-2 open,2-3 closed b. Fault (Any Alarm): Pins 1-2 closed, 2-3 open M:\TECHNOTE\25T022.DOC 27

Back to. Communication Products Group. Technical Notes. Local/Remote Control, 9300 Series

Back to. Communication Products Group. Technical Notes. Local/Remote Control, 9300 Series Back to Communication Products Group Technical Notes 25T001 Local/Remote Control, 9300 Series MITEQ TECHNICAL NOTE 25T001 MAY 1995 REV G 1.0 LOCAL/REMOTE SELECTION LOCAL/REMOTE CONTROL 9300 SERIES CONVERTER

More information

OPERATION & MAINTENANCE MANUAL FOR U-9353 UPCONVERTER JANUARY 2001 CUSTOMER

OPERATION & MAINTENANCE MANUAL FOR U-9353 UPCONVERTER JANUARY 2001 CUSTOMER Ref.: XXXXX OPERATION & MAINTENANCE MANUAL FOR U-9353 UPCONVERTER JANUARY 2001 CUSTOMER MAXXXXXU 114525E Rev.A The suffix XXXXX following part numbers in this manual is a unique number assigned at time

More information

EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1586-06 RF Attenuator May 2009 Rev A 1 2 3 12.5 53.5 16.3 MODEL 1586 RF ATTENUATOR CROSS TECHNOLOGIES INC. EXECUTE PS1 PS2 Data, drawings, and other material contained herein are

More information

The MP SERIES CONTROLLER. User s Manual. ISE, Inc.

The MP SERIES CONTROLLER. User s Manual. ISE, Inc. The MP SERIES CONTROLLER User s Manual ISE, Inc. 10100 Royalton Rd. Cleveland, OH 44133 USA Tel: (440) 237-3200 Fax: (440) 237-1744 http://variac.com Form No, 003-1622 Rev G 02/25/2009 Form No. 003-1622

More information

Instruction Sheet UPS SERIES. Serial Control Protocol. I Rev E

Instruction Sheet UPS SERIES. Serial Control Protocol. I Rev E Instruction Sheet UPS SERIES Serial Control Protocol I-00341 Rev E (THIS PAGE INTENTIONALLY LEFT BLANK) Page 1 TABLE OF CONTENTS 1 Protocol Overview...3 1.1 Signal characteristics...3 1.2 Primary DB9 Pin

More information

Appendix A. Datum Systems PSM-2100/512 Satellite Modem. Technical Specification

Appendix A. Datum Systems PSM-2100/512 Satellite Modem. Technical Specification Appendix A Datum Systems PSM-2100/512 Satellite Modem Technical Specification PSM-2100 and PSM-512 VSAT / SCPC - Modem Specification Revision History Rev 1.0 6-15-97 Preliminary Release. Rev 1.1 10-10-97

More information

EVDP610 IXDP610 Digital PWM Controller IC Evaluation Board

EVDP610 IXDP610 Digital PWM Controller IC Evaluation Board IXDP610 Digital PWM Controller IC Evaluation Board General Description The IXDP610 Digital Pulse Width Modulator (DPWM) is a programmable CMOS LSI device, which accepts digital pulse width data from a

More information

USING RS-232 to RS-485 CONVERTERS (With RS-232, RS-422 and RS-485 devices)

USING RS-232 to RS-485 CONVERTERS (With RS-232, RS-422 and RS-485 devices) ICS DataCom Application Note USING RS- to RS- CONVERTERS (With RS-, RS- and RS- devices) INTRODUCTION Table RS-/RS- Logic Levels This application note provides information about using ICSDataCom's RS-

More information

MODEL 4212C INSTRUCTION MANUAL. Table of contents 1.1 FEATURES 1.4 WARRANTY

MODEL 4212C INSTRUCTION MANUAL. Table of contents 1.1 FEATURES 1.4 WARRANTY MODEL 4212C INSTRUCTION MANUAL Table of contents Page 1 1 2 3 6 6 6 1. GENERAL INFORMATION 1.1 FEATURES 1.2 INSTRUMENT IDENTIFICATION & OPTIONS 1.3 TECHNICAL SPECIFICATIONS 1.4 WARRANTY 1.5 UNPACKING AND

More information

TABLE OF CONTENTS. Keypad Programming Manual 1

TABLE OF CONTENTS. Keypad Programming Manual 1 TABLE OF CONTENTS How To Program Radios...2 Keypad Programming...2 A. Navigation...3 1. Group Parameters (CH 00)...4 2. Channel Parameters (CH 01 - CH20)...4 3. Global Parameters (GRP 00)...5 B. Group

More information

1. GENERAL INFORMATION

1. GENERAL INFORMATION 1. GENERAL INFORMATION 1.1 FEATURES The Instrulab model 4221C Programmable RTD Temperature Monitor utilizes microprocessor technology to produce a stable, high accuracy instrument with simple customized

More information

Agilent 3499A/B/C Switch/Control system

Agilent 3499A/B/C Switch/Control system User s Guide Copyright Agilent Technologies, Inc. 2000, 2002 For Safety information, Warranties, and Regulatory information, see the pages following the Index. Agilent 399A/B/C Switch/Control system Agilent

More information

ST600 TRANSMITTER OPERATING INSTRUCTIONS

ST600 TRANSMITTER OPERATING INSTRUCTIONS ST600 TRANSMITTER OPERATING INSTRUCTIONS 1892 1273 These operating instructions are intended to provide the user with sufficient information to install and operate the unit correctly. The Wood and Douglas

More information

PRODUCT MANUAL VHF & UHF Pocket Paging Transmitter. Version 1.00 April 2017

PRODUCT MANUAL VHF & UHF Pocket Paging Transmitter. Version 1.00 April 2017 11-85-0000 VHF & UHF Pocket Paging Transmitter PRODUCT MANUAL Version 1.00 April 2017 Copyright 2017 Sea Air and Land Communications Ltd. All rights reserved. P a g e 1 Salcom Product Documentation This

More information

CONNECT SYSTEMS INCORPORATED 5321 Derry Ave., Suite B Agoura Hills, CA FLEX SERIES UNIVERSAL CONTROLLER

CONNECT SYSTEMS INCORPORATED 5321 Derry Ave., Suite B Agoura Hills, CA FLEX SERIES UNIVERSAL CONTROLLER CONNECT SYSTEMS INCORPORATED 5321 Derry Ave., Suite B Agoura Hills, CA 91301 Phone (805) 642-7184 Fax (805) 642-7271 FLEX SERIES UNIVERSAL CONTROLLER FLEX IIIA CTCSS COMMUNITY TONE PANEL User s Instruction

More information

5700A/5720A Series II Multi-Function Calibrator

5700A/5720A Series II Multi-Function Calibrator 5700A/5720A Series II Multi-Function Calibrator Operator Guide PN 601648 May 1996 1996 Fluke Corporation, Inc. All rights reserved. Printed in U.S.A. Contents What is in this Guide?... 2 Safety Summary...

More information

5700A/5720A. Operator Guide. Series II Multi-Function Calibrator

5700A/5720A. Operator Guide. Series II Multi-Function Calibrator 5700A/5720A Series II Multi-Function Calibrator Operator Guide PN 3474006 May 1996, Rev. 1, 5/09 2009 Fluke Corporation. All rights reserved. Printed in USA. All product names are trademarks of their respective

More information

Interfacing to the SoundStation VTX 1000 TM with Vortex Devices

Interfacing to the SoundStation VTX 1000 TM with Vortex Devices Interfacing to the SoundStation VTX 1000 TM with Vortex Devices Application Note Polycom Installed Voice Business Group September 2004 Rev. F TABLE OF CONTENTS TABLE OF CONTENTS... 2 INTRODUCTION... 6

More information

Stensat Transmitter Module

Stensat Transmitter Module Stensat Transmitter Module Stensat Group LLC Introduction The Stensat Transmitter Module is an RF subsystem designed for applications where a low-cost low-power radio link is required. The Transmitter

More information

Technical Description and User Manual E-band CW power meter DPM-12 s/n N-1204/21-T

Technical Description and User Manual E-band CW power meter DPM-12 s/n N-1204/21-T ELVA-1 Microwave Ltd. S.A. Mm-wave Division e-mail: sales@elva-1.com Internet: http://www.elva-1.com/ Technical Description and User Manual E-band CW power meter DPM-12 s/n N-1204/21-T 1 Specifications

More information

Multi-Channel RS-232 Serial RF Transceiver

Multi-Channel RS-232 Serial RF Transceiver RF-232 Multi-Channel RS-232 Serial RF Transceiver The RF-232 subassembly is a multi-channel serial radio transceiver. This device accepts and outputs standard serial data at one of three selectable data

More information

APPLICATION BULLETIN. SERIAL BACKGROUNDER (Serial 101) AB23-1. ICS ICS ELECTRONICS division of Systems West Inc. INTRODUCTION CHAPTER 2 - DATA FORMAT

APPLICATION BULLETIN. SERIAL BACKGROUNDER (Serial 101) AB23-1. ICS ICS ELECTRONICS division of Systems West Inc. INTRODUCTION CHAPTER 2 - DATA FORMAT ICS ICS ELECTRONICS division of Systems West Inc. AB- APPLICATION BULLETIN SERIAL BACKGROUNDER (Serial 0) INTRODUCTION Serial data communication is the most common means of transmitting data from one point

More information

TX4400 UHF CB RADIO INSTRUCTION MANUAL TX4400 INSTRUCTION MANUAL PAGE 1

TX4400 UHF CB RADIO INSTRUCTION MANUAL TX4400 INSTRUCTION MANUAL PAGE 1 TX4400 UHF CB RADIO INSTRUCTION MANUAL TX4400 INSTRUCTION MANUAL PAGE 1 TABLE OF CONTENTS GENERAL................................... 3 FEATURES.................................. 3 BASIC OPERATION...4 Front

More information

MODES AND PROTOCOL HANDLING

MODES AND PROTOCOL HANDLING A R T A D V A N C E D R A D I O T E C H N O L O G I E S R A D I O M O D E M S E R I E S The State of the Art ART Series was designed as a result of extensive market research. The product will therefore

More information

S O P H I S T I C A T E D A U T O M A T I O N

S O P H I S T I C A T E D A U T O M A T I O N S O P H I S T I C A T E D A U T O M A T I O N Introduction Cost-effective Radio modems to any serial communication application Low power models, different frequency ranges RS232 / / RS422 / 5V TTL interface

More information

NetPage Network Wireless Paging System (POCSAG) NP-14 Series. Operation Manual CCW

NetPage Network Wireless Paging System (POCSAG) NP-14 Series. Operation Manual CCW NetPage Network Wireless Paging System (POCSAG) NP-14 Series Operation Manual CCW152241-002 1 INTRODUCTION The NP-14 Network wireless paging system is a fully-programmable, single-board, POCSAG encoder

More information

Agilent 33250A 80 MHz Function / Arbitrary Waveform Generator. User s Guide

Agilent 33250A 80 MHz Function / Arbitrary Waveform Generator. User s Guide User s Guide Publication Number 33250-90002 (order as 33250-90100 manual set) Edition 2, March 2003 Copyright Agilent Technologies, Inc. 2000, 2003 For Safety information, Warranties, and Regulatory information,

More information

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features AR-DN-RS232 An-10 / Rapid RS232 Interface Product Guide Overview The AR-DN-RS232 is a device that is used as a 2 way gateway between third party systems and the CP An-10 or Rapid lighting control systems

More information

SECTION III OPERATION

SECTION III OPERATION SECTION III OPERATION 3.1 INTRODUCTION This section contains information concerning the operation procedures for the BK Radio GPH Flex Mode Series handheld VHF radios. Information on installation and programming

More information

Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 4.00 and greater

Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 4.00 and greater Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 4.00 and greater For additional information contact matedev@outbackpower.com Page 1 of 20 Revision History Revision 2.0:

More information

BATCHMATE 1500 Batch Control Computer Technical Bulletin

BATCHMATE 1500 Batch Control Computer Technical Bulletin TS-5(C) BATCHMATE 5 Batch Control Computer Technical Bulletin DESCRIPTION The BATCHMATE features an 8 digit.55-in. alphanumeric LED display. The pulse input model will accept up to 2, pulses per second

More information

TX3420 REMOTE MOUNT UHF RADIO

TX3420 REMOTE MOUNT UHF RADIO TX3420 REMOTE MOUNT UHF RADIO Introduction........................... 2 Important information concerning uhf cb radio................. 2 Emergency channels.................... 3 telemetry channels.....................

More information

CONNECT SYSTEMS INCORPORATED 1802 Eastman Ave., Suite 116 Ventura, Ca FLEX SERIES UNIVERSAL CONTROLLER

CONNECT SYSTEMS INCORPORATED 1802 Eastman Ave., Suite 116 Ventura, Ca FLEX SERIES UNIVERSAL CONTROLLER CONNECT SYSTEMS INCORPORATED 1802 Eastman Ave., Suite 116 Ventura, Ca. 93003 Phone (805) 642-7184 Fax (805) 642-7271 FLEX SERIES UNIVERSAL CONTROLLER FLEX IIIA LTR CONTROLLER AND COMMUNITY TONE PANEL User

More information

Mastr III P25 Base Station Transmitter Tune-up Procedure

Mastr III P25 Base Station Transmitter Tune-up Procedure Mastr III P25 Base Station Transmitter Tune-up Procedure 1. Overview The Mastr III Base Station transmitter alignment is performed in several steps. First, the Transmit Synthesizer module is aligned to

More information

Modbus communication module for TCX2: AEX-MOD

Modbus communication module for TCX2: AEX-MOD Modbus communication module for TCX2: Communication Specification TCX2 is factory installed in TCX2 series controllers with -MOD suffix, and is also available separately upon request for customer installation

More information

Henry Dudley 1508 Wellington Ave. Toms River, NJ

Henry Dudley 1508 Wellington Ave. Toms River, NJ Henry Dudley 1508 Wellington Ave. Toms River, NJ 08757 732-240-6895 hdudley@dudleylab.com OM000001 REV01 RELEASE DATE 1/27/04 TABLE OF CONTENTS TABLE OF CONTENTS... 2 1.0 GENERAL INFORMATION... 3 1.1 Scope

More information

Ocean Controls KT-5221 Modbus IO Module

Ocean Controls KT-5221 Modbus IO Module Ocean Controls Modbus IO Module 8 Relay Outputs 4 Opto-Isolated Inputs 2 Analog Inputs (10 bit) 1 PWM Output (10 bit) 4 Input Counters Connections via Pluggable Screw Terminals 0-5V or 0-20mA Analog Inputs,

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual M518 Rev. B Model 1030F Indicator-Totalizer Model 1030F Indicator-Totalizer Installation, Operation and Maintenance Manual Table of Contents General... 1 Installation... 1 Operation... 7 Programming...

More information

745 Transformer Protection System Communications Guide

745 Transformer Protection System Communications Guide Digital Energy Multilin 745 Transformer Protection System Communications Guide 745 revision: 5.20 GE publication code: GEK-106636E GE Multilin part number: 1601-0162-A6 Copyright 2010 GE Multilin GE Multilin

More information

Protocol and instruction set for remote control via the infrared interface. Table of Contents

Protocol and instruction set for remote control via the infrared interface. Table of Contents Application information 7 HD mini20 HD 3000 Series HD 4000 Series Protocol and instruction set for remote control via the infrared interface Table of Contents 1 Technical Principles...2 2 Protocol...2

More information

Ku-Band VSAT Block Up Converters

Ku-Band VSAT Block Up Converters FEATURES Single box BUC output power levels to 10W RS485 M&C capability Accurate RF Power Monitoring Maintenance Free Operation +24VDC or +48 VDC input voltage OPTIONS 10W L-Band to Ku-Band Block Up Converter

More information

CW Transmitter. User s Manual

CW Transmitter. User s Manual CW Transmitter User s Manual Warranty Statement PRAXSYM warrants that all items will be free from defects in material and workmanship under use as specified in this guide for a period of one year from

More information

ThunderBolt Display. by Adam Maurer, VK4GHZ

ThunderBolt Display. by Adam Maurer, VK4GHZ ThunderBolt Display by Adam Maurer, VK4GHZ Overview ThunderBolt Display is a stand-alone microprocessor-controlled LCD specifically for Trimble s ThunderBolt Disciplined Clock, providing a comprehensive

More information

ROM/UDF CPU I/O I/O I/O RAM

ROM/UDF CPU I/O I/O I/O RAM DATA BUSSES INTRODUCTION The avionics systems on aircraft frequently contain general purpose computer components which perform certain processing functions, then relay this information to other systems.

More information

KAPPA M. Radio Modem Module. Features. Applications

KAPPA M. Radio Modem Module. Features. Applications KAPPA M Radio Modem Module Features Intelligent RF modem module Serial data interface with handshake Host data rates up to 57,600 baud RF Data Rates to 115Kbps Range up to 500m Minimal external components

More information

MODBUS RS485 SERIAL PROTOCOL

MODBUS RS485 SERIAL PROTOCOL MODBUS RS485 SERIAL PROTOCOL ED39DIN DMM3 VIP39DIN VIP396 SIRIO STAR3 STAR3din VERSION 09 JULY 2004 Modbus SIRIO.doc 09 JULY 2004 Pag.1/22 The STAR3, STAR3 din, VIP396, VIP39din, DMM3, SIRIO and ED39din

More information

Model FLSC-C1-LIQ. Microprocessor Based Loop Powered Transmitter

Model FLSC-C1-LIQ. Microprocessor Based Loop Powered Transmitter Model FLSC-C1-LIQ Microprocessor Based Loop Powered Transmitter CONTENTS 1. Introduction ------------------------------------------------------------ 2 2. Specifications-----------------------------------------------------------

More information

CIC ENGINEERING 345 CENTER STREET EAST PEORIA, IL PH FAX µmpis Control Software

CIC ENGINEERING 345 CENTER STREET EAST PEORIA, IL PH FAX µmpis Control Software µmpis Control Software Overview The µmpis Control software package allows for a user to control the operation of the umpis unit with a PC. The PC and the umpis unit are connected together using a RS232

More information

Interfacing the 1724-Type Microprocessor-Controlled EDFA via a Serial Communication Port

Interfacing the 1724-Type Microprocessor-Controlled EDFA via a Serial Communication Port Application Note Interfacing the 1724-Type Microprocessor-Controlled EDFA via a Serial Communication Port Introduction The 1724-type erbium-doped fiber amplifier (EDFA) is a precision, microprocessor-controlled,

More information

HP 33120A Function Generator / Arbitrary Waveform Generator

HP 33120A Function Generator / Arbitrary Waveform Generator Note: Unless otherwise indicated, this manual applies to all Serial Numbers. The HP 33120A is a high-performance 15 MHz synthesized function generator with built-in arbitrary waveform capability. Its combination

More information

3 AXIS RF ELECTROMAGNETIC FIELD METER

3 AXIS RF ELECTROMAGNETIC FIELD METER 50 MHz to 3 GHz Radio Frequency Radiation Meters Electromagnetic Field strength measurement 3 AXIS RF ELECTROMAGNETIC FIELD METER Model : EMF-819 Your purchase of this RF EMF METER marks a step forward

More information

EE 314 Spring 2003 Microprocessor Systems

EE 314 Spring 2003 Microprocessor Systems EE 314 Spring 2003 Microprocessor Systems Laboratory Project #9 Closed Loop Control Overview and Introduction This project will bring together several pieces of software and draw on knowledge gained in

More information

BEI Device Interface User Manual Birger Engineering, Inc.

BEI Device Interface User Manual Birger Engineering, Inc. BEI Device Interface User Manual 2015 Birger Engineering, Inc. Manual Rev 1.0 3/20/15 Birger Engineering, Inc. 38 Chauncy St #1101 Boston, MA 02111 http://www.birger.com 2 1 Table of Contents 1 Table of

More information

G3P-R232. User Manual. Release. 2.06

G3P-R232. User Manual. Release. 2.06 G3P-R232 User Manual Release. 2.06 1 INDEX 1. RELEASE HISTORY... 3 1.1. Release 1.01... 3 1.2. Release 2.01... 3 1.3. Release 2.02... 3 1.4. Release 2.03... 3 1.5. Release 2.04... 3 1.6. Release 2.05...

More information

RF Wireless Serial Device Server

RF Wireless Serial Device Server RF-SDS RF Wireless Serial Device Server The RF-SDS subassembly is a radio transceiver acting as a Serial Device Server, which externally connects a remote serial RF transceiver to an Ethernet network (TCP/IP).

More information

SDI SPECTRADYNAMICS, INC.

SDI SPECTRADYNAMICS, INC. SPECTRADYNAMICS, INC. Low Noise Frequency Synthesizer LNFS-400 Operating Manual SPECTRADYNAMICS, INC 1849 Cherry St., Unit 2 Louisville, CO 80027 Phone: (303) 665-1852 Fax: (303) 604-6088 Table of Contents

More information

Model OT-1000-HH 1GHz SuperMod Optical Transmitter, DWDM ADVANCED OPERATING MANUAL

Model OT-1000-HH 1GHz SuperMod Optical Transmitter, DWDM ADVANCED OPERATING MANUAL Model OT-1000-HH 1GHz SuperMod Optical Transmitter, DWDM ADVANCED OPERATING MANUAL The features mentioned in this Advanced OT-1000-HH Manual can be accessed only with the optional OT-NEC-A, Network Element

More information

PathTrax. User s Manual. PathTrax. The solution for making easy shielding effectiveness measurements

PathTrax. User s Manual. PathTrax. The solution for making easy shielding effectiveness measurements PathTrax User s Manual The solution for making easy shielding effectiveness measurements PathTrax TABLE OF CONTENTS Chapter 1 General Information 2 Introduction Specifications Receiver Transmitter Chapter

More information

IQADA00 Single/Dual Channel Analog Audio Distribution Amplifier

IQADA00 Single/Dual Channel Analog Audio Distribution Amplifier IQADA00 Single/Dual Channel Analog Audio Distribution Amplifier C Module Description... 2 Rear Panel Views... 2 Product Comparison... 2 Block Diagram... 4 Features... 4 Technical Profile... 5 INPUT AND

More information

Instruction Manual Model Block Translator

Instruction Manual Model Block Translator Instruction Manual Model 2083-21-1422 Block Translator October 2018, Rev. 0 1385>2230 G=20 TRX=846.001010 MHz MENU MODEL 2083 TRANSLATOR CROSS TECHNOLOGIES INC. REMOTE POWER ALARM EXECUTE Data, drawings,

More information

Pegasus. Programmer s Reference Guide TEN-TEC

Pegasus. Programmer s Reference Guide TEN-TEC Pegasus Programmer s Reference Guide TEN-TEC Contents Interface Settings... 3 The PC to Radio Connection... 4 Hardware Vs Software... 4 System Overview... 5 Power-Up and Restart Sequence... 6 Transmitter

More information

OPERATING MANUAL Series. FM Portable Radio. Intrinsically-Safe SMARTNET, SmartZone Conventional

OPERATING MANUAL Series. FM Portable Radio. Intrinsically-Safe SMARTNET, SmartZone Conventional 7700 Series OPERATING MANUAL FM Portable Radio Intrinsically-Safe SMARTNET, SmartZone Conventional 1 LAND MOBILE PRODUCT WARRANTY - The manufacturer s warranty statement for this product is available

More information

Product Specification for model TT Transducer Tester Rev. B

Product Specification for model TT Transducer Tester Rev. B TT Rev B April 20, 2010 Product Specification for model TT Transducer Tester Rev. B The Rapid Controls model TT Rev B transducer tester connects to multiple types of transducers and displays position and

More information

SMS control unit for SRK transmitters

SMS control unit for SRK transmitters SMS control unit for SRK transmitters Ver 1.00 13 February 2014 Initial release Ver 1.01 14 February 2014 Updated POWER and GAIN syntax Ver 1.02 13 April 2014 Added photo Added TX ON, TX OFF, AUX ON an

More information

APPENDIX A PARAMETER DESCRIPTIONS

APPENDIX A PARAMETER DESCRIPTIONS APPENDIX A PARAMETER DESCRIPTIONS CONTENTS Page INTRODUCTION A.5 CHANNEL PARAMETERS #101 -#102 Channel Frequencies A.5 #103 Microcomputer Clock Offset A.6 #104 Transmitter Power A.6 #105 Squelch A.6 #106

More information

Carbon Dioxide (Tiny CO2) Gas Sensor. Rev TG400 User Manual

Carbon Dioxide (Tiny CO2) Gas Sensor. Rev TG400 User Manual Carbon Dioxide (Tiny CO2) Gas Sensor Rev. 1.2 TG400 User Manual The TG400 measuring carbon dioxide (chemical formula CO2) is a NDIR (Non-Dispersive Infrared) gas sensor. As it is contactless, it has high

More information

Data Isolation Cards. 2-Wire HDSL/56KBS Isolation Card P Wire HDSL/56KBS Isolation Card P30050

Data Isolation Cards. 2-Wire HDSL/56KBS Isolation Card P Wire HDSL/56KBS Isolation Card P30050 Data Isolation Cards 2-Wire HDSL/56KBS Isolation Card P30076 4-Wire HDSL/56KBS Isolation Card P30050 Printed in USA 12/11 T0331 Rev. A Table of Contents Page 1.0 SCOPE 2 2.0 PRODUCT OVERVIEW 2 2.1 System

More information

Stensat Radio Beacon

Stensat Radio Beacon Stensat Radio Beacon Stensat Group LLC Introduction The Stensat radio beacon is a small FM transmitter capable of generating AX.25 Unnumbered Information (UI) packets at 1200 bps AFSK and 9600 bps FSK.

More information

USER'S MANUAL. Model : K

USER'S MANUAL. Model : K USER'S MANUAL Model : 2000-64K TM GINA MODEL 2000-64K Overview GINA Model 2000-64K is a stand-alone, high frequency data transceiver using spread spectrum technology. GINA 2000-64K capabilities include

More information

Section 5 Coin Acceptor/Changer VMC/Peripheral Communication Specifications

Section 5 Coin Acceptor/Changer VMC/Peripheral Communication Specifications Section 5 Coin Acceptor/Changer VMC/Peripheral Communication Specifications 5.1 Introduction This section defines the communication bytes sent and received by a coin accepting device ( Changer ). As defined

More information

TNM96-ETL Energy Meter & Electrical Powermeter

TNM96-ETL Energy Meter & Electrical Powermeter TNM96-ETL Energy Meter & Electrical Powermeter Celsa Messgeräte GmbH Barthelsmühlring 16, 76870 Kande - Germany Telefon: +49 7275 9883-0; Telefax: +49 7275 9883-33 Web: www.celsagermany.com; E-Mail: info@celsagermany.com

More information

AT-XTR-7020A-4. Multi-Channel Micro Embedded Transceiver Module. Features. Typical Applications

AT-XTR-7020A-4. Multi-Channel Micro Embedded Transceiver Module. Features. Typical Applications AT-XTR-7020A-4 Multi-Channel Micro Embedded Transceiver Module The AT-XTR-7020A-4 radio data transceiver represents a simple and economical solution to wireless data communications. The employment of an

More information

OPERATING GUIDE OPERATING GUIDE FOR IC-F5060/F6060 SERIES BIIS 1200/MDC 1200 SYSTEM/ LTR /IDAS NXDN OPERATION

OPERATING GUIDE OPERATING GUIDE FOR IC-F5060/F6060 SERIES BIIS 1200/MDC 1200 SYSTEM/ LTR /IDAS NXDN OPERATION OPERATING GUIDE OPERATING GUIDE FOR IC-F060/F6060 SERIES BIIS 100/MDC 100 SYSTEM/ LTR /IDAS NXDN OPERATION IMPORTANT Thank you for purchasing this Icom transceiver. The BIIS 100/MDC 100 system/ltr /IDAS

More information

Hub and Cluster. ogramming Manual. Pro MAN3090

Hub and Cluster. ogramming Manual. Pro MAN3090 Hub and Cluster Pro ogramming Manual MAN3090 Contents Introduction 3 Radio Channels 28 System Overview 3 Currently Used 30 RCC RCC Ch 30 System Design 4 Device RCC Ch 30 Manual Select 30 Compatibility

More information

Select datum Page backward in. parameter list

Select datum Page backward in. parameter list HEIDENHAIN Working with the measured value display unit ND Actual value and input display (7-segment LED, 9 decades and sign) Select datum Page backward in parameter list Confirm entry value Set display

More information

1:1 AND 1:2 REDUNDANT LOW-NOISE AMPLIFIER SYSTEMS

1:1 AND 1:2 REDUNDANT LOW-NOISE AMPLIFIER SYSTEMS FEATURES Low amplifier noise temperature Fully redundant power supplies Remote control via RS485 matic/manual control from both local and remote mode Remote status Off-line input/output access Amplifier

More information

WTPCT-M. eeder. Pulse Counter/Timer Module. Technologies FEATURES SPECIFICATIONS DESCRIPTION. Weeder Technologies

WTPCT-M. eeder. Pulse Counter/Timer Module. Technologies FEATURES SPECIFICATIONS DESCRIPTION. Weeder Technologies eeder Technologies 90-A Beal Pkwy NW, Fort Walton Beach, FL 32548 www.weedtech.com 850-863-5723 Pulse Counter/Timer Module FEATURES Reads frequency from 0.50000 to 1,400,000 Hz using 5 digit resolution

More information

Serial Control Hardware (RS-485)

Serial Control Hardware (RS-485) Serial Control Hardware (RS-485) The RS-485 port is available on either of the RJ45 connectors on the back panel of the unit. The 485 network operates at 19.2 kbaud, 8 bits, 1 stop bit/no parity/no hardware

More information

FastLink TM. Network. Operation and Installation Manual

FastLink TM. Network. Operation and Installation Manual FastLink TM Network Operation and Installation Manual C6570 C6571 C6571S C6572 C6572S C6573S Store and Forward Controller Network Store and Forward Controller Service Store and Forward Controller Network

More information

Optiva RF-Over-Fiber Design Tool User s Guide. Revision 1.0 March 27, 2015

Optiva RF-Over-Fiber Design Tool User s Guide. Revision 1.0 March 27, 2015 Optiva RF-Over-Fiber Design Tool User s Guide Revision 1.0 March 27, 2015 2015 Jenco Technologies Inc. All rights reserved. Every attempt has been made to make this material complete, accurate, and up-to-date.

More information

This section of the manual will document the Ad-Maestro s control ports, COMM Ports and their settings respectively.

This section of the manual will document the Ad-Maestro s control ports, COMM Ports and their settings respectively. This section of the manual will document the Ad-Maestro s control ports, COMM Ports and their settings respectively. Parallel - The Parallel port provides a control interface with video devices utilizing

More information

Kongsberg Mesotech Ltd.

Kongsberg Mesotech Ltd. Kongsberg Mesotech Ltd. Doc. No. : 974-00007904 Title : Digital Telemetry Notes elease : Version 1.4 Date : 2010-04-30 1. PUPOSE This document briefly describes the digital telemetry standards, formats

More information

For Safety information, Warranties, and Regulatory information, see the pages behind the Index.

For Safety information, Warranties, and Regulatory information, see the pages behind the Index. User s Guide Part Number: E3631-90002 April 2000. For Safety information, Warranties, and Regulatory information, see the pages behind the Index. Copyright Agilent Technologies, Inc. 2000 All Rights Reserved.

More information

DESIGNED BY THE BLACK TANK USER MANUAL

DESIGNED BY THE BLACK TANK USER MANUAL DESIGNED BY THE BLACK TANK USER MANUAL Table of Contents Your CubeConnect Transceiver Product Description... 5 What s In the Box... 6 CubeConnect Transceiver Interface... 7 CubeConnect Transceiver Modes

More information

BandMaster V Manual. Installation

BandMaster V Manual. Installation BandMaster V Manual Installation Installing and configuring the BM-5 BandMaster V is a simple process. All the configuration process is done from the front panel. Installation and configuration steps are

More information

MADEinUSA OPERATOR S MANUAL. RS232 Interface Rev. A

MADEinUSA OPERATOR S MANUAL. RS232 Interface Rev. A MADEinUSA OPERATOR S MANUAL RS232 Interface 92-3006 Rev. A www.iradion.com Iradion Laser, Inc. 51 Industrial Dr. N. Smithfield, RI 02896 (410) 762-5100 Table of Contents 1. Overview... 2 2. Equipment Required...

More information

2W UHF MHz Radio Transceiver

2W UHF MHz Radio Transceiver 2W UHF410-470 MHz Radio Transceiver Specification Copyright Javad Navigation Systems, Inc. February, 2006 All contents in this document are copyrighted by JNS. All rights reserved. The information contained

More information

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model 6012-06XR Specifications & Dimensions 2 Theory of Operation 3 System Block Diagram 4 Operator Controls & Connectors 5 Test Connections

More information

X R T B A S E S T A T I O N S E R I E S

X R T B A S E S T A T I O N S E R I E S X R T B A S E S T A T I O N S E R I E S The State of the Art XRT Base Station Series was designed for the scanning Telemetry market, as a result of extensive market research into the requirements of utility

More information

Arduino Arduino RF Shield. Zulu 2km Radio Link.

Arduino Arduino RF Shield. Zulu 2km Radio Link. Arduino Arduino RF Shield RF Zulu 2km Radio Link Features RF serial Data upto 2KM Range Serial Data Interface with Handshake Host Data Rates up to 38,400 Baud RF Data Rates to 56Kbps 5 User Selectable

More information

Temperature Controller model MFC-301/T-Dry. Version for Dry Transformers and Motors. Technical Manual. Licht

Temperature Controller model MFC-301/T-Dry. Version for Dry Transformers and Motors. Technical Manual. Licht Temperature Controller model MFC-301/T-Dry Version for Dry Transformers and Motors Technical Manual Licht Contents 1 Introduction 2 2 Operating principle 3 2.1 General principle 3 2.2 RTD operation 3 3

More information

C-Band VSAT Block Up Converters

C-Band VSAT Block Up Converters FEATURES Single box BUC output power levels to 20W RS485 M&C capability Accurate RF Power Monitoring Maintenance Free Operation +24VDC or +48 VDC input voltage OPTIONS Antenna Mounting Kit Form A Summary

More information

HR1200. Version 1.00 ATIM RADIOCOMMUNICATION 1/11

HR1200. Version 1.00 ATIM RADIOCOMMUNICATION 1/11 HR1200 Version 1.00 ATIM RADIOCOMMUNICATION 1/11 Contact Information ATIM RADIOCOMMUNICATION Les guillets 38250 Villard de Lans France Tel : +33 (0)4 76 95 50 65 Fax: +33 (0)4 76 95 50 64 Web : www.atim.com

More information

MICROWAVE FREQUENCY SYNTHESIZER QP-FSPLL USER MANUAL

MICROWAVE FREQUENCY SYNTHESIZER QP-FSPLL USER MANUAL MICROWAVE FREQUENCY SYNTHESIZER QP-FSPLL-0040-01 USER MANUAL The QP-FSPLL-0040-01 is a low-phase noise wideband synthesizer operating from 50 MHz to 40 GHz with a nominal output power of +15 dbm. The synthesizer

More information

GPS Time and Frequency Reference Receiver

GPS Time and Frequency Reference Receiver $ GPS Time and Frequency Reference Receiver Symmetricom s 58540A GPS time and frequency reference receiver features: Eight-channel, parallel tracking GPS engine C/A Code, L1 Carrier GPS T-RAIM satellite

More information

Physics 472, Graduate Laboratory DAQ with Matlab. Overview of data acquisition (DAQ) with GPIB

Physics 472, Graduate Laboratory DAQ with Matlab. Overview of data acquisition (DAQ) with GPIB 1 Overview of data acquisition (DAQ) with GPIB The schematic below gives an idea of how the interfacing happens between Matlab, your computer and your lab devices via the GPIB bus. GPIB stands for General

More information

C191HM POWERMETER AND HARMONIC MANAGER COMMUNICATIONS REFERENCE GUIDE

C191HM POWERMETER AND HARMONIC MANAGER COMMUNICATIONS REFERENCE GUIDE C191HM POWERMETER AND HARMONIC MANAGER COMMUNICATIONS ASCII Communications Protocol REFERENCE GUIDE Every effort has been made to ensure that the material herein is complete and accurate. However, the

More information

Select datum Page backward in parameter list

Select datum Page backward in parameter list HEIDENHAIN Working with the measured value display unit ND Actual value and input display (7-segment LED, 9 decades and sign) Select datum Page backward in parameter list Confirm entry value Set display

More information

Precise Counting Scale GC. User Manual SNOWREX INTERNATIONAL CO., LTD. SRGC

Precise Counting Scale GC. User Manual SNOWREX INTERNATIONAL CO., LTD. SRGC Precise Counting Scale GC User Manual SNOWREX INTERNATIONAL CO., LTD. SRGC 20100415 Table of Contents Table of Contents...1 Specifications... 2 Basic specification... 2 Series specification(ec TYPE/OIML

More information

Key Reference. Agilent Technologies E8663B Analog Signal Generator

Key Reference. Agilent Technologies E8663B Analog Signal Generator Agilent Technologies E8663B Analog Signal Generator For the latest revision of this guide, go to http://www.agilent.com/find/e8663b and click Product Library. Manufacturing Part Number: E8663-90004 Printed

More information