SUPER COMPACT - SCP 6 SUPER COMPACT
|
|
- Ginger Henry
- 6 years ago
- Views:
Transcription
1 SPER OMPT - SP 6 SPER OMPT
2 SP SPER OMPT SETION ONTENTS 8 Features 14 Feeder elements 15 Distribution Elements 16 Expansion elements 17 Fire barrier elements 18 Elbows 20 Double elbows 24 T-elements 26 onnection interfaces 28 Elbows with connection interface 30 Double elbows with connection interface 34 Section isolator 36 Feed units 38 Tap-off boxes 41 Fixing supports 44 Phase transposition and with neutral rotation 44 End cover 45 Protection accessories 46 Riser mains 47 Transformer connections 48 The EdM transformer advantage 49 The Legrand XL 3 advantage 50 Installation guidelines 52 Measurement guidelines 53 ertificates 54 SP Technical Data 56 SP5 Technical Data 58 SP2N Technical Data 97 alculating the operating current 7 IG POWER GENERL TLOGE
3 SP Features SP is the Zucchini line used for transport and distribution of igh Power, and is also highly valued in rising mains. The applications include all industrial, commercial and service sector buildings ( factories, banks, trade and business centres, hospitals, etc.) The Super ompact SP line is available in the standard range: from 630 to 4000 with aluminum alloy conductors and from 800 to 5000 with copper conductors. The super-compact dimensions of the SP enhance its resistance to short circuit stresses; in addition, they can reduce the impedance of the circuit by controlling the voltage drops and allow for the installation of high power electrical systems, even in extremely confined spaces. SP is available with a wide selection of tapoff boxes that range from 63 up to 1250, thus allowing you to locally protect and feed different types of loads by housing protective devices such as fuses, Ms and motorised switches. SP, as all Zucchini products, is not only in compliance with the harmonised Standards EI EN / 2 but also answers specifically to many clients needs for more severe conditions of use. Thus the rated current of Zucchini s busbar trunking systems is always referred to the average ambient temperature of 40 against the 35 required by the Standard, thus providing the markets with suitably upgraded products. The nominal range of all SP Super-ompact busbars is guaranteed both for horizontal installations (flat and edgewise) and for vertical installations without downgrading. SP busbar trunking systems are designed so that they can be maintenance-free, except for the periodic and compulsory inspections required by the Standard IE The tightening torque inspection of the junction can be carried out by qualified personnel, even when the busbar is energized. 8 SPER OMPT
4 SP SPER OMPT SP Features SFETY The best protection for your system FLEXIILITY dapts to all present and future needs SIMPLIITY solution for everyone Notes: The product versions in the whole catalogue will be simplified as shown opposite, highlighting the part with the monobloc installed in red and the neutral side in blue. Neutral monobloc 9 IG POWER GENERL TLOGE
5 General structural features The outer casing of the SP line consists of four -ribbed section bars, bordered and riveted (thickness 1.5mm), with excellent mechanical, electric and heat loss efficiency. The sheetmetal is made of hot galvanized steel, treated according to NI EN327 and painted with RL7035 resins with a high resistance to chemical agents. The standard degree of protection is IP55; also, with certain accessories (see pag. 45), it can also be installed outdoors. The busbar conductors have a rectangular crosssection with rounded corners; there are two versions: - Electrolytic copper ETP 99.9 NI EN luminum alloy treated over the entire surface with 5 galvanic processes (copper plating + tin plating) The insulation between bars is ensured by a double sheath made with polyester film (total thickness 0.4 mm) class, class F (155 ) thermal resistance available on request. ll plastic components have a V1 self-extinguishing degree (as per L94); they are fire retardant and comply with the glow-wire test according to standards. Th SP line i alogen Free. In order to facilitate storage operations especially to reduce the installation time, the straight elements, trunking components as well as all the components of the SP Super ompact line are supplied with a monobloc pre-installed at the factory. The junction contact is ensured by two silverplated copper plates for each phase, insulated with red class F thermosetting plastic material. The monobloc has shearhead bolts: after tightening the nuts with a standard wrench, the outer head will break at the correct torque value, hence giving you the certainty that the connection has been made properly so as to guarantee safety and maximum performance over time. Finally, in order to completely verify the insulation level, every element with a monobloc undergoes an insulation test (phase-phase, phase-pe) at the factory with a test voltage of 5000V. Standard versions: SP line with 4 conductors 3L+N+PE, 3L+PEN, 3L+FE+PE Note: For dimension, see technical data section PE: Protection Earth FE: Functional Earth (lean Earth) 130 N L1 L2 L3 PE SP5 line with 5 conductors 3L+N+FE+PE Note: For dimension, see technical data section PE: Protection Earth FE: Functional Earth (lean Earth) 140 FE N L1 L2 L3 PE SP2N 200% neutral line 3L+2N+PE Note: For dimension, see technical data section PE: Protection Earth FE: Functional Earth (lean Earth) 140 2N L1 L2 L3 PE Special versions on request SPER OMPT
6 SP SPER OMPT Zucchini - Legrand EdM system concept Group synergy allows for immediate integration between ZINI busbar trunking systems, EdM cast resin transformers and Legrand XL³ cabinets. EdM cast resin transformers can be made to order with a pre-installed interface connection for the ZINI busbar trunking systems. XL³ cabinet assemblies have been tested together with the Zucchini SP busbars in order to provide the guarantee of a certified system. The following versions represent only some of the many standardized solutions. certified system. Transformer luminium busbar kv Insulation class 400 V current l k 6% Family onnection component (kv) (kv) () (k) SP 00 l P SP 1250 l P SP 1600 l P SP 2000 l P SP 2500 l P SP 3200 l P SP 4000 l P Transformer opper busbar kv Insulation class 400 V current l k 6% Family onnection component (kv) (kv) () (k) SP 00 u P SP 1250 u P SP 1600 u P SP 2000 u P SP 2500 u P SP 3200 u P SP 4000 u P (l k 7%) SP 5000 u P 11 IG POWER GENERL TLOGE
7 Main features of the SP line Straight elements: Supplied with its pre-installed monobloc. Feeder elements: - standard length: 3m - special length: from 1m to 3m Distribution elements with tap-off outlets: - standard length: 3m, 2m, 1m - standard tap-off sockets: spaced at 850mm intervals on both sides dditional elements: Supplied with its pre-installed monobloc. Elements able to meet any installation requirement. Elements with S120 fire barrier Elements with phase transposition Elements with thermal expansion device N N ngle components: Supplied with its pre-installed monobloc. Elements able to meet any change of direction with standard or special solutions. Elbows Double elbows Special T, X elements 12 SPER OMPT
8 SP SPER OMPT Tap-off boxes: Elements used for connecting and energizing electric loads. Plug-in tap-off boxes from 63 up to 630: (can be installed with busbar energized) - with 3P fuse holders - with switch disconnector and fuse holder - for DPX circuit breakers olted tap-off boxes from 125 to 1250: - with switch disconnector and fuse holder - for DPX circuit breakers onnection interfaces: Elements used for connecting the busbar to the cabinet or transformer. Solutions for Legrand XL³ cabinets and EdM cast resin transformers niversal solutions Fixing supports: Elements used for fixing the busbar to the structure of the building. Options for horizontal installations Options for vertical installations Options for special applications (seismic areas, naval environment) 13 IG POWER GENERL TLOGE
9 Feeder elements FEEDER ELEMENT - STNDRD 0 mm luminium L = 0 mm P P P P P P P P P L = mm P P P P P P P P P L = mm P P P P P P P P P L = mm P P P P P P P P P L = mm P P P P P P P P P opper L = 0 mm P P P P P P P P P L = mm P P P P P P P P P L = mm P P P P P P P P P L = mm P P P P P P P P P L = mm P P P P P P P P P 0 (L) Dimension changes with the rating; it is specified in the specifications on page MINIMM ND MXIMM DIMENSIONS OF SINGLE ND DOLE R luminium 630 to 4000 opper 800 to 5000 (L) min/mx [mm] 00/0 14 SPER OMPT
10 SP SPER OMPT Distribution elements ELEMENTS FOR PLG-IN TYPE TP-OFF OXES - STNDRD 0MM Tap-off outlets on both sides luminium No. of outlets 630* L = 0 mm P P P P P P P P P L = 2000 mm P P P P P P P P P L = 00 mm P P P P P P P P P opper No. of outlets 800* L = 0 mm P P P P P P P P P L = 2000 mm P P P P P P P P P L = 00 mm P P P P P P P P P 0 (L) ompatible boxes are listed on pages Dimension changes with the rating; it is specified in the specifications on page * Element with tap-off outlets only on top side (3+0) MINIMM ND MXIMM DIMENSIONS OF SINGLE ND DOLE R luminium 630 to 4000 opper 800 to 5000 (L) min/mx [mm] 00/0 IG POWER GENERL TLOGE 15
11 Trunking components EXPNSION ELEMENT luminium P P P P P P P P P opper P P P P P P P P P 0 Dimension changes with the rating; it is specified in the specifications on page The expansion units absorbs the thermal expansion during normal use that, on long runs, would otherwise cumulate and put abnormal force on the connection points The expansion unit is to be placed in the straight runs of more than 40m and repeated every 40m. e.g. straight section length m 70 = 1 element with expansion in the middle of the line 120 m e.g. straight section length m 120 = 2 elements with expansion every ~40 m 16 SPER OMPT
12 SP SPER OMPT Fire barriers FIRE RRIER S120 (EN , DIN 42-09) luminium internal 653IF IF01 653IF01 653IF01 external 652EF01 652EF01 652EF01 652EF01 652EF02 652EF03 653EF02 653EF03 653EF04 opper internal 653IF IF01 653IF01 653IF01 external 652EF01 652EF01 652EF01 652EF02 652EF02 652EF03 653EF02 653EF03 653EF04 Dimension changes with the rating; it is specified in the specifications on page Fire barrier S120 When ordering, specify the element that will be equipped with an internal fire barrier. Due to the geometry of the models 800 to 2000 in aluminium and 00 to 2500 in copper, the internal fire barrier is not needed. The external fire barrier can be used on any trunking component in compliance with the operating instructions specified in figures 1 and 2. Figure 1 No fire barrier No fire barrier 200 Figure 2 No fire barrier IG POWER GENERL TLOGE
13 Direction changes ORIZONTL ELOW luminium Type 1 Standard R 60280P P P P P P P P P Type 2 Standard L P P P P P P P P P Type 1 Special R P P P P P P P P P Type 2 Special L P P P P P P P P P opper Type 1 Standard R 65280P P P P P P P P P Type 2 Standard L P P P P P P P P P Type 1 Special R P P P P P P P P P Type 2 Special L P P P P P P P P P Dimension changes with the rating; it is specified in the specifications on page The dimensions are referred to standard elements. The word special is referred to an element with measurements that are different from those shown in the figure, yet included between the MIN/MX values specified in the table. MINIMM ND MXIMM DIMENSIONS OF SINGLE R luminium 630 to 2000 opper 800 to 2500 () min/mx [mm] 250/1299 () min/mx [mm] 250/1299 MINIMM ND MXIMM DIMENSIONS OF DOLE R luminium 2500 to 4000 opper 3200 to 5000 () min/mx [mm] 250/1449 () min/mx [mm] 250/1449 Type 1 Type 2 18 SPER OMPT
14 SP SPER OMPT Direction changes VERTIL ELOW luminium Type 2 Standard R P P P P P P P P P Type 1 Standard L P P P P P P P P P Type 2 Special R P P P P P P P P P Type 1 Special L P P P P P P P P P opper Type 2 Standard R P P P P P P P P P Type 1 Standard L P P P P P P P P P Type 2 Special R P P P P P P P P P Type 1 Special L P P P P P P P P P 450 Dimension changes with the rating; it is specified in the specifications on page The dimensions are referred to standard elements. The ones used for elements are in bold type. 450 The word special is referred to an element with measurements that are different from those shown in the figure, yet included between the MIN/MX values specified in the table. MINIMM ND MXIMM DIMENSIONS OF SINGLE R luminium 630 to 2000 opper 800 to 2500 () min/mx [mm] /1299 () min/mx [mm] /1299 MINIMM ND MXIMM DIMENSIONS OF DOLE R luminium 2500 to 4000 opper 3200 to 5000 () min/mx [mm] 450/1449 () min/mx [mm] 450/1449 Type 1 Type 2 19 IG POWER GENERL TLOGE
15 Direction changes DOLE ORIZONTL ELOW luminium Type 1 Right P P P P P P P P P Type 2 Left P P P P P P P P P opper Type 1 Right P P P P P P P P P Type 2 Left P P P P P P P P P Dimension changes with the rating; it is specified in the specifications on page The dimensions are referred to standard elements. Non Standard elements (with measurements that are different from those shown in the figure) are referred to the MIN/MX values specified in the table. MINIMM ND MXIMM DIMENSIONS OF SINGLE R luminium 630 to 2000 opper 800 to 2500 () min/mx [mm] 250/1299 () min/mx [mm] 50/599 () min/mx [mm] 250/1299 MINIMM ND MXIMM DIMENSIONS OF DOLE R luminium 2500 to 4000 opper 3200 to 5000 () min/mx [mm] 250/1449 () min/mx [mm] 50/599 () min/mx [mm] 250/1449 Type 1 Type 2 20 SPER OMPT
16 SP SPER OMPT Direction changes DOLE VERTIL ELOW luminium Type 2 Right P P P P P P P P P Type 1 Left P P P P P P P P P opper Type 2 Right P P P P P P P P P Type 1 Left P P P P P P P P P 450 Dimension changes with the rating; it is specified in the specifications on page The dimensions are referred to standard elements. The ones used for elements are in bold type Non Standard elements (with measurements that are different from those shown in the figure) are referred to the MIN/MX values specified in the table. MINIMM ND MXIMM DIMENSIONS OF SINGLE R luminium 630 to 2000 opper 800 to 2500 () min/mx [mm] /1299 () min/mx [mm] 50/599 () min/mx [mm] /1299 MINIMM ND MXIMM DIMENSIONS OF DOLE R luminium 2500 to 4000 opper 3200 to 5000 () min/mx [mm] 450/1449 () min/mx [mm] 50/599 () min/mx [mm] 450/1449 Type 1 Type 2 21 IG POWER GENERL TLOGE
17 Direction changes DOLE ELOW ORIZONTL+VERTIL luminium Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P opper Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Dimension changes with the rating; it is specified in the specifications on page The dimensions are referred to standard elements. The ones used for elements are in bold type. 450 Non Standard elements (with measurements that are different from those shown in the figure) are referred to the MIN/MX values specified in the table. MINIMM ND MXIMM DIMENSIONS OF SINGLE R luminium 630 to 2000 opper 800 to 2500 () min/mx [mm] 250/1299 () min/mx [mm] () min/mx [mm] /1299 MINIMM ND MXIMM DIMENSIONS OF DOLE R luminium 2500 to 4000 opper 3200 to 5000 () min/mx [mm] 250/1449 () min/mx [mm] () min/mx [mm] 450/1449 Type 1 Type 3 Type 2 Type 4 22 SPER OMPT
18 SP SPER OMPT Direction changes DOLE ELOW VERTIL+ORIZONTL luminium Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P opper Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Dimension changes with the rating; it is specified in the specifications on page The dimensions are referred to standard elements. The ones used for elements are in bold type. Non Standard elements (with measurements that are different from those shown in the figure) are referred to the MIN/MX values specified in the table. MINIMM ND MXIMM DIMENSIONS OF SINGLE R luminium 630 to 2000 opper 800 to 2500 () min/mx [mm] /1299 () min/mx [mm] () min/mx [mm] 250/1299 Type 1 Type 2 MINIMM ND MXIMM DIMENSIONS OF DOLE R luminium 2500 to 4000 opper 3200 to 5000 () min/mx [mm] 450/1449 () min/mx [mm] () min/mx [mm] 250/1449 Type 3 Type 4 23 IG POWER GENERL TLOGE
19 Direction changes VERTIL T luminium Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P opper Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Dimension changes with the rating; it is specified in the specifications on page The dimensions are referred to standard elements. The ones used for elements are in bold type. Non Standard elements (with measurements that are different from those shown in the figure) are referred to the MIN/MX values specified in the table. MINIMM ND MXIMM DIMENSIONS OF SINGLE R luminium 630 to 2000 opper 800 to 2500 () min/mx [mm] /1299 () min/mx [mm] /1299 () min/mx [mm] /1299 Type 1 Type 2 MINIMM ND MXIMM DIMENSIONS OF DOLE R luminium 2500 to 4000 opper 3200 to 5000 () min/mx [mm] 450/1449 () min/mx [mm] 450/1449 () min/mx [mm] 450/1449 Type 3 Type 4 24 SPER OMPT
20 SP SPER OMPT Direction changes ORIZONTL T luminium Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P opper Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Dimension changes with the rating; it is specified in the specifications on page The dimensions are referred to standard elements. Non Standard elements (with measurements that are different from those shown in the figure) are referred to the MIN/MX values specified in the table. Type 1 Type 2 MINIMM ND MXIMM DIMENSIONS OF SINGLE ND DOLE R luminium 630 to 4000 opper 800 to 5000 () min/mx [mm] 550/49 () min/mx [mm] 550/49 () min/mx [mm] 550/49 Type 3 Type 4 25 IG POWER GENERL TLOGE
21 onnection interfaces STNDRD ONNETION INTERFE luminium Type 2 R P P P P P P P P P Type 1 L 6028P P P P P P P P P Type 2 Special R P P P P P P P P P Type 1 Special L P P P P P P P P P opper Type 2 R P P P P P P P P P Type 1 L 6528P P P P P P P P P Type 2 Special R P P P P P P P P P Type 1 Special L P P P P P P P P P (2) Dimension changes with the rating; it is specified in the specifications on page The dimensions are referred to standard elements. The ones used for elements are in bold type. (1) 200 The word special is referred to an element with measurements that are different from those shown in the figure, yet included between the MIN/MX values specified in the table. See page 25 for dimensions of coverplate (1) and bars (2). Special element with non-standard centre distance E D F G Dimensioning indications to be provided when using a non-standard centre distance MINIMM ND MXIMM DIMENSIONS OF SINGLE ND DOLE R luminium 630 to 4000 opper 800 to 5000 () min/mx [mm] 200/00 () min/mx [mm] 150/400 Type 1 Type 2 26 SPER OMPT
22 SP SPER OMPT onnection interfaces OVERPLTE DRILLING DETILS (1) 330 luminium 630 to 2000 opper 800 to Ø luminium 2500 to 3200 opper 3200 to Ø luminium 4000 opper Ø R DRILLING DETILS (2) l u l u l 1250 l 1600 u oles 9 x 30 oles 15 x l 2000 u 2500 l u oles 9 x 30 oles 15 x l u l 4000 u 5000 oles 9 x 30 oles 15 x IG POWER GENERL TLOGE
23 onnection interfaces ONNETION INTERFE + ORIZONTL ELOW luminium Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P opper Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P 200 Dimension changes with the rating; it is specified in the specifications on page The dimensions are referred to standard elements (2) (1) Non Standard elements (with measurements that are different from those shown in the figure) are referred to the MIN/MX values specified in the table. See page 25 for dimensions of coverplate (1) and bars (2). MINIMM ND MXIMM DIMENSIONS OF SINGLE R luminium 630 to 2000 opper 800 to 2500 () min/mx [mm] 150/400 () min/mx [mm] 165/1299 () min/mx [mm] 250/1299 Type 1 Type 2 MINIMM ND MXIMM DIMENSIONS OF DOLE R luminium 2500 to 4000 opper 3200 to 5000 () min/mx [mm] 150/400 () min/mx [mm] 165/1449 () min/mx [mm] 250/1449 Type 3 Type 4 28 SPER OMPT
24 SP SPER OMPT onnection interfaces ONNETION INTERFE + VERTIL ELOW luminium Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P opper Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Dimension changes with the rating; it is specified in the specifications on page The dimensions are referred to standard elements. The ones used for elements are in bold type. Non Standard elements (with measurements that are different from those shown in the figure) are referred to the MIN/MX values specified in the table See page 25 for dimensions of coverplate (1) and bars (2). (2) (1) MINIMM ND MXIMM DIMENSIONS OF SINGLE R luminium 630 to 2000 opper 800 to 2500 () min/mx [mm] 150/400 () min/mx [mm] /1299 () min/mx [mm] /1299 MINIMM ND MXIMM DIMENSIONS OF DOLE R luminium 2500 to 4000 opper 3200 to 5000 () min/mx [mm] 150/400 () min/mx [mm] 450/1449 () min/mx [mm] 450/1449 Type 1 Type 3 Type 2 Type 4 29 IG POWER GENERL TLOGE
25 onnection interfaces ONNETION INTERFE + DOLE ORIZONTL ELOW luminium Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P opper Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Dimension changes with the rating; it is specified in the specifications on page The dimensions are referred to standard elements. The ones used for elements are in bold type. Non Standard elements (with measurements that are different from those shown in the figure) are referred to the MIN/MX values specified in the table See page 25 for dimensions of coverplate (1) and bars (2). (2) (1) MINIMM ND MXIMM DIMENSIONS OF SINGLE R luminium 630 to 2000 opper 800 to 2500 () min/mx [mm] 150/400 () min/mx [mm] 0/1299 () min/mx [mm] 50/599 () min/mx [mm] 250/1299 Type 1 Type 2 MINIMM ND MXIMM DIMENSIONS OF DOLE R luminium 2500 to 4000 opper 3200 to 5000 () min/mx [mm] 150/400 () min/mx [mm] 165/1449 () min/mx [mm] 50/599 () min/mx [mm] 250/1449 Type 3 Type 4 30 SPER OMPT
26 SP SPER OMPT onnection interfaces ONNETION INTERFE + DOLE VERTIL ELOW luminium Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P opper Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Dimension changes with the rating; it is specified in the specifications on page The dimensions are referred to standard elements. The ones used for elements are in bold type. Non Standard elements (with measurements that are different from those shown in the figure) are referred to the MIN/MX values specified in the table (2) (1) 450 See page 25 for dimensions of coverplate (1) and bars (2). MINIMM ND MXIMM DIMENSIONS OF SINGLE R luminium 630 to 2000 opper 800 to 2500 () min/mx [mm] 150/400 () min/mx [mm] 200/1299 () min/mx [mm] 50/599 () min/mx [mm] /1299 MINIMM ND MXIMM DIMENSIONS OF DOLE R luminium 2500 to 4000 opper 3200 to 5000 () min/mx [mm] 150/400 () min/mx [mm] 350/1449 () min/mx [mm] 50/599 () min/mx [mm] 450/1449 Type 1 Type 3 Type 2 Type 4 31 IG POWER GENERL TLOGE
27 onnections interfaces ONNETION INTERFE + VERTIL ELOW + ORIZONTL ELOW luminium Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P opper Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Dimension changes with the rating; it is specified in the specifications on page The dimensions are referred to standard elements. The ones used for elements are in bold type. Non Standard elements (with measurements that are different from those shown in the figure) are referred to the MIN/MX values specified in the table See page 25 for dimensions of coverplate (1) and bars (2). (2) (1) Type 1 Type 2 Type 3 MINIMM ND MXIMM DIMENSIONS OF SINGLE R luminium 630 to 2000 opper 800 to 2500 () min/mx [mm] 150/400 () min/mx [mm] 200/1299 () min/mx [mm] () min/mx [mm] 250/1299 Type 4 Type 5 Type 6 MINIMM ND MXIMM DIMENSIONS OF DOLE R luminium 2500 to 4000 opper 3200 to 5000 () min/mx [mm] 150/400 () min/mx [mm] 350/1449 () min/mx [mm] () min/mx [mm] 250/1449 Type 7 Type 8 32 SPER OMPT
28 SP SPER OMPT onnection interfaces ONNETION INTERFE + ORIZONTL ELOW + VERTIL ELOW luminium Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P opper Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Type P P P P P P P P P Dimension changes with the rating; it is specified in the specifications on page The dimensions are referred to standard elements. The ones used for elements are in bold type. 450 Non Standard elements (with measurements that are different from those shown in the figure) are referred to the MIN/MX values specified in the table See page 25 for dimensions of coverplate (1) and bars (2). (1) Type 1 Type 2 Type 3 MINIMM ND MXIMM DIMENSIONS OF SINGLE R luminium 630 to 2000 opper 800 to 2500 () min/mx [mm] 150/400 () min/mx [mm] 0/1299 () min/mx [mm] () min/mx [mm] /1299 MINIMM ND MXIMM DIMENSIONS OF DOLE R luminium 2500 to 4000 opper 3200 to 5000 () min/mx [mm] 150/400 () min/mx [mm] 165/1449 () min/mx [mm] () min/mx [mm] 450/1449 Type 4 Type 7 Type 5 Type 8 Type 6 33 IG POWER GENERL TLOGE
29 omplementary run components SETION ISOLTOR E D The section isolator allows to protect and disconnect one part of the installation from the rest of the run. Dimension changes with the rating; it is specified in the specifications on page It is possible to have the opening of the box with a position different from that shown in the picture (different types indicated below). The direction of the disconnector (fuses) must be specifi ed when ordering. The bolted boxes are to be installed when the busbar is disconnected and not energized. For operating voltages (e) different from 400V, please contact Zucchini. Type 1 Type 2 GENERL DIMENSIONS OF TE DISONNETOR WIT REFERENE TO TE RTING Dimensions according D E to type 1 From 630 to 1250 (in mm) From 1600 to 2500 (in mm) Type 3 Type 4 34 SPER OMPT
30 SP SPER OMPT omplementary run components RTE REDER WIT ISOLTOR SWIT E D Dimension changes with the rating; it is specified in the specifications on page It is possible to have the opening of the box with a position different from that shown in the picture (different types indicated below). The direction of the reducer must be specified when ordering. Please contact Zucchini for more details on the dimensions of the reducer. Fuses not included. See Legrand catalogue. The bolted boxes are to be installed when the busbar is disconnected and not energized. For operating voltages (e) different from 400V, please contact Zucchini. Type 1 Type 2 GENERL DIMENSIONS OF TE DISONNETOR WIT REFERENE TO TE RTING Dimensions according D E to type 1 From 630 to 1250 (in mm) From 1600 to 2500 (in mm) Type 3 Type 4 35 IG POWER GENERL TLOGE
31 Feed units END FEED NIT luminium Type 2 R P P P P P P P P P Type 1 L P P P P P P P P P opper Type 2 R P P P P P P P P P Type 1 L P P P P P P P P P Dimension changes with the rating; it is specified in the specifications on page RER LE INPT luminium gland plate(s) for cable entry 170mm x 4mm Single bar : 1 plate Double bar : 2 plates For dimensions of holes for connections, see page 27 DIMENSIONS OF TE OX luminium 630 to to to 4000 opper 800 to to to 5000 () [mm] () [mm] () [mm] Type 1 Type 2 36 SPER OMPT
32 SP SPER OMPT olt-on tap-off boxes WIT 23 SWIT DISONNETOR ND FSE RRIER : 125 TO 1250 luminium N P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P opper N P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P In order to fi nalize the order, it is necessary to specify the type of Super ompact the box will be installed on. The boxes cannot be installed simultaneously on both sides of the same junction. E WRNING The bolted boxes are to be installed directly on the junction when the busbar is disconnected and not energized. For operating voltages (e) different from 400V please contact Zucchini. Fuses not included. See Legrand catalogue. D Rated insulating voltage i [V] 00 Rated impulse withstand voltage imp [kv] 12 Type of rated duty 23 Rated conditional short circuit current [k] 0 EI EN DIMENSIONS OF TE OX ox rating 125 to to 1250 () [mm] () [mm] () [mm] (D) [mm] (E) [mm] IG POWER GENERL TLOGE
33 Tap-off boxes EMPTY TP-OFF OX 125 TO 1250 : OLT-ON TYPE Rear cable input WRNING The bolted boxes are to be installed when the busbar is disconnected and not energized. In order to finalize the order, it is necessary to specify the type of Super ompact the box will be installed on. E Tap-off boxes can be pre-equipped with DPX moulded case circuit breakers (M) upon request. D DIMENSIONS OF TE OX ox rating 125 to to 1250 () [mm] () [mm] () [mm] (D) [mm] (E) [mm] TP-OFF OX WIT 23 SWIT DISONNETOR ND FSE RRIER, 125 TO 400 : PLG-IN TYPE Rear cable input 340 ox rating Fuse Items 125 N P 250 N P 400 N P 550 Rated insulating voltage i [V] 00 Rated impulse withstand voltage imp [kv] 12 Type of rated duty 23 Rated conditional short circuit current [k] 0 EI EN an be installed and removed when the busbar is energized. To be applied on elements with any rating, with tap-off outlets For operating voltages (e) different from 400V, please contact Zucchini. Fuses not included. See Legrand catalogue SPER OMPT
34 SP SPER OMPT Tap-off boxes TP-OFF OX 63 TO 630 : PLG-IN TYPE WIT FSE RRIER Rating Fuse Items P 125 N P 160 N P 250 N P 630 N P over with 21 disconnection Polyester coated, galvanized steel structure. Metal boxes are suitable for heavy loads and are used to shield electromagnetic fields caused by flows of current. Fuses not included. WIT SWIT DISONNETOR (23) Rating Items P P P P P P Polyester coated, galvanized steel structure. Metal boxes are suitable for heavy loads and are used to shield electromagnetic fields caused by flows of current. These tap-off boxes are equipped with a switch disconnector (23) and a fuse carrier. The disconnector switch is operated through a rotary handle on the cover (not shown in the picture). N.. over with 21 disconnection: it is not possible to open, close, install or pull out the tap-off box if the switch is in ON position Fuses not included. See Legrand catalogue. an be installed and removed when the busbar is energized. To be applied on elements with any rating, with tap-off outlets from 63 to 160 Side cable input over with 21 disconnection 34 Side cable input from 250 to IG POWER GENERL TLOGE
35 Tap-off boxes EMPTY TP-OFF OX 63 TO 630 over with 21 disconnection onnection terminals for cables max 50mm EMPTY VERSION Rating Items P P P P P Tap-off boxes can be pre-equipped with DPX moulded case circuit breakers (M) upon request. an be installed and removed when the busbar is energized. To be applied on elements with any rating, with tap-off outlets luminium cable entry plates on both sides from 63 to 160 over with 21 disconnection 34 luminium cable entry plates on both sides from 250 to SPER OMPT
36 SP SPER OMPT Fixing supports SSPENSION RKET FOR EDGEWISE INSTLLTION L busbars Dimension u busbars Dimension EDGEWISE ELEMENT 2000 (MX 0) 1 15 M Slot 9x SSPENSION RKET FOR FLT INSTLLTION l busbars Dimension u busbars Dimension FLT ELEMENT 2000 (MX 0) M 130 Slot 9x IG POWER GENERL TLOGE
37 Fixing supports RKETS FOR VERTIL ELEMENTS luminium Type 1 Type 1 Type 1 Type 1 Type 1 Type 2 Type 3 Type 4 Type 4 - with bracket and springs with bracket with springs D - bracket only E - naval applications anti-seismic opper Type 1 Type 1 Type 1 Type 1 Type 1 Type 2 Type 3 Type 4 Type 4 - with bracket and springs with bracket with springs D - bracket only E - naval applications anti-seismic WIT RKET ND SPRINGS WIT NTI-SEISMI RKET* WIT SPRINGS D RKET ONLY E NVL PPLITIONS *: For elements, the standard bracket is also anti-seismic rated. For elements, there is a specific anti-seismic bracket part number. 42 SPER OMPT
38 SP SPER OMPT Fixing supports Dimensions 30 Ø9 170 x Type 1 Type Ø9 170 x x Slot 9x30 Slot 9x30 Type 3 Ø9 174 Y x Y Slot 9x30 Ø9 174 Y Type 4 Y X 30 Y Y Slot 9x30 X ND Y DIMENSIONS OF TE RKETS Type 1 Type 1 Type 2 Type 2 Type 3 Type 4 Type 4 luminium 630 to opper 800 to x [mm] y [mm] IG POWER GENERL TLOGE
39 Transposition element End cover TRNSPOSITION ELEMENTS luminium Phase transposition P P P P P P P P P Neutral rotation P P P P P P P P P opper Phase transposition P P P P P P P P P Neutral rotation P P P P P P P P P 1200 N In particularly long carrying sections (>0 metres) it is recommended to insert two transposition elements always by two: (one placed at 1/3 and one placed at 2/3 of the trunking path) to balance the electric impedance of the system. e.g.: in a m line one phase transposition at 0m and one at 200m. N Phase transposition Dimension changes with the rating; it is specified in the specifications on page N N Neutral rotation When the sequence of the distribution board phases is different from that of the transformer, it is possible to use an element that allows a neutral rotation. Please refer to Zucchini for more information. END OVER IP55 luminium P P P P P P P P P opper P P P P P P P P P 175 ompletes the IP55 Degree of protection of the line 44 SPER OMPT
40 400 SP SPER OMPT Protection accessories PROTETIVE OVER FOR OTDOOR PPLITIONS owl owl Edgewise element Flat element overing accessory to be used for outdoor installations and wherever the standard IP55 Degree of protection is not adequate. PROTETIVE ELLOWS luminium 630 to to 4000 SF SF opper 800 to to 5000 SF SF () Single bar SF Recommended for protection of the interface connection on panelboards, dry-type transformer with enclosure and oil-type transformers. For EdM cast resin transformers, custom-made connections are available upon request (see p.48) () () Double bar SF () 45 IG POWER GENERL TLOGE
41 Operating instructions on how to design riser mains N L1 L2 L3 [7] [1] se an R end feed unit (without monobloc). In order to position the tap-off boxes correctly, the neutral conductor of the riser main must be on the left side of the element. [3] [2] se one or more suspension brackets for the vertical elements, according to the weight of the whole riser mains. For risers that are shorter than 4 metres, fix to the base with type brackets (see p.42) when longer, use a type suspension bracket (see p. 42) every kg of risers (including the boxes). [5] [3] se a standard suspension bracket to hang the busbar every 2 metres of riser mains. [4] se elements with tap-off outlets (see page 13). [4] [6] [5] se S120 fire barrier kit for each compartment floor (see page 15). [6] The tap-off boxes can be installed in the tap-off outlets and near the connection between the elements. In both cases, the boxes extend downward. N [7] t the end of the riser mains, position the IP55 end cover. N [2] N N [1] (For further information, please refer to the technical guide) 46 SPER OMPT
42 SP SPER OMPT Zucchini transformer connections FLEXILE RID ONNETIONS luminium No. of braids per phase Length [mm] -450 F00 F00 F2000 F0 F5000 F6000 F4000 F5000 F F0020 F0020 F F020 F F F F F F0030 F0030 F F030 F F F F F More than 750 F0099 F0099 F F099 F F F F F opper No. of braids per phase Length [mm] -450 F00 F2000 F0 F5000 F6000 F4000 F5000 F6000 F F0020 F F020 F F F F F F F0030 F F030 F F F F F F More than 750 F0099 F F099 F F F F F F When ordering, specify: holes on transformer side (dimensions,, Ø D) and length L. holes on busbar side see page 25 L holes on transformer side to be specified Ø D The distance between the phases can be designed according to your needs Transformer Example of a vertical connection 47 IG POWER GENERL TLOGE
43 The system: The EdM transformer advantage TYPE SETP The Legrand group product synergy answers to the global installation need. The EdM cast resin transformers have specifically designed connections for the Zucchini busbars. The versions shown represent some of the standardized solutions. Lv side For the outgoing busbar run from the transformer, see pages TYPE SETP Lv side TYPE SETP Lv side TR ONNETION INTERFE In order to achieve an TR element, it is necessary to have the technical drawing of the transformer. ast resin transformer 48 SPER OMPT
44 SP SPER OMPT The system: The Legrand XL³ advantage INSTLLTION KIT FOR MS 400 INET Item kit for reinforcing the roof of the XL³ cabinets for the installation of the Zucchini interface to connect the busbar systems The Super ompact SP range can be easily and immediately combined with the Legrand XL³ 4000 cabinets. The reinforcement kit enables you to install any type of unit to the board (see page 24-31) onto the roof of the XL³ structure in a quick and easy way. pon request, and with the specific measurements, custom made connections between the SP interface and the DMX air-circuit breaker can be supplied for installation in the XL³ cabinets The safety and the operational efficiency of the Zucchini - Legrand system are guaranteed by the system certification, achieved after rigorous tests carried out in the most important international laboratories. For more details about the XL³, please refer to the Legrand atalogue. IG POWER GENERL TLOGE 49
45 Installation guidelines MINIMM DISTNE OF TE WLL / EILING ELEMENTS Wall eiling eiling Wall Wall When there are tap-off units along the busbars, the minimum distances depend on the dimensions of the tap-offs selected. Wall eiling Wall * * When there is a tap-off box installed above the busbar, check the overall dimension of the open cover of the tap-off unit used in the section specified on pages Wall eiling Wall 80 Minimum installation distance when there are several adjacent lines Wall eiling 0 0 Wall 60 (For further information, please refer to the technical guide) Minimum installation distance when there are several overlapped lines 50 SPER OMPT
46 SP SPER OMPT Installation guidelines INSTLLTION SEQENE OF TE JNTION The installation instructions are placed on every element near the junction (Fig.1) Make sure that the contacts are clean. 30 mm Join the two elements together. (Fig. 1) (Fig. 2) 270 mm Make sure that the earth plate of the straight element is inserted behind the front plate of the junction monobloc (Fig.2) The positioning pin on the monobloc should be fitted into the corresponding slot on the earth plate. Verify the distance between elements, 270mm, before tightening the monobloc completely (Fig.3). (Fig. 3) Tighten the bolt of the monobloc until the 1st head breaks off (Fig. 4). The bolt that tightens the monobloc has a second head which is used when carrying out operations or inspections on the line. The nominal tightening torque is 85Nm. (Fig. 4) 85Nm Install the covers of the junction (Fig. 5). (Fig. 5) onnection completed correctly with degree of protection IP55 (Fig. 6). For further information, please refer to the technical guide. (Fig. 6) 51 IG POWER GENERL TLOGE
47 Measurement of special element lengths MESREMENT OF STRIGT ELEMENTS dimension Q N The exact length of the piece to be ordered can be determined by measuring the distance between the elements (as shown in the picture) and then subtracting 270 mm from the dimension that has been taken. Length of element = Q - 270mm Example: dimension measured = 2500 mm order a 2230 mm element MESREMENT OF SPEIL TRNKING ELEMENTS = Q2-70 mm ORIZONTL ELOW Q1 = Q1-70 mm The exact length of the piece to be ordered can be determined by measuring the dimensions Q1 and Q2 (as shown in the picture) and then subtracting 70 mm from each dimension that has been taken. Dimension of the element to order: = Q1-70 mm = Q2-70 mm For further information, please refer to the technical guide. Q2 52 SPER OMPT
48 SP SPER OMPT ertificates The Super-ompact has been given Type-pproval ertifications by the most prestigious Electro-technical agencies: ertificate of ompliance with Standards EI (E - LOVG) RIN Type-pproval (Italian Register of Shipping) S Type-pproval (merican ureau of Standard) GOST Type-pproval (Russia) REI120 fire resistance measurements Noise measurements (ESI) Fire resistance measurements with Fire arrier Electromagnetic emissions measurements Mechanical vibration resistance measurements (Dynamic Test - ENEL YDRO) 53 IG POWER GENERL TLOGE
49 130 Technical data SP (3L+N+PE) N L1 L2 L3 PE LMINIM Rated current I n [] asing overall dimensions L x [mm] 130x x x x x x x x x480 Operating voltage [V] Insulation voltage i [V] Frequency [z] 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Rated short-time current for three-phase fault (1 s) I W [k]rms llowable peak current for three-phase fault I pk [k] Rated short-time current for single-phase fault (1 s) I W [k]rms llowable peak current for single-phase fault I pk [k] llowable specific energy for three-phase fault I 2 t [M 2 s] Phase resistance R 20 [mω/m] Phase reactance (50 z) X [mω/m] Phase impedance Z [mω/m] Phase resistance at thermal conditions R t [mω/m] Phase impedance at thermal conditions Z [mω/m] Neutral resistance R 20 [mω/m] Resistance of the protective conductor (PE 1) R PE [mω/m] Resistance of the protective conductor (PE 2) R PE [mω/m] Resistance of the protective conductor (PE 3) R PE [mω/m] Reactance of the protective conductor (50 z) X PE [mω/m] Resistance of the fault loop (PE 1) R o [mω/m] Resistance of the fault loop (PE 2) R o [mω/m] Resistance of the fault loop (PE 3) R o [mω/m] Reactance of the fault loop (50 z) X o [mω/m] Impedance of the fault loop (PE 1) Z o [mω/m] Impedance of the fault loop (PE 2) Z o [mω/m] Impedance of the fault loop (PE 3) Z o [mω/m] Zero-sequence resistance phase - N R o [mω/m] Zero-sequence reactance phase - N X o [mω/m] Zero-sequence Impedance phase - N Z o [mω/m] Zero-sequence resistance phase- PE R o [mω/m] Zero-sequence reactance phase - PE X o [mω/m] Zero-sequence Impedance phase - PE Z o [mω/m] cosϕ = cosϕ = Voltage drop factor with cosϕ = aduta distributed tensione load con carico distribuito k [V/m/] -6 cosϕ = ΔV = k. L. I. e -6 [V] cosϕ = cosϕ = cosϕ = Weight (PE 1) p [kg/m] Weight (PE 2) p [kg/m] Weight (PE 3) p [kg/m] Fire load [kwh/m] Degree of protection IP Thermal resistance class of the insulating materials /F * /F * /F * /F * /F * /F * /F * /F * /F * Joule effect losses at rated current P [W/m] Min/Max mbient Temperature [ ] -5/50-5/50-5/50-5/50-5/50-5/50-5/50-5/50-5/50 * lass F thermal resistance (155 ) available on request - Regulations and conformity: IE/EN ; DIN VDE Product suitable for onstant/yclic Warm, humid climates: DIN IE 68 part 2-3; DIN IE 68 part Degree of protection: IP55; IPx7 carrying lines available with accessories, on request - Insulation and surface treatment of the conductors: Insulated conductors for the whole length, aluminum copper-plated and tin-plated - usbar casing material: 1.5mm galvanized steel plate, pre-painted or stainless steel (available, if required, with special paint and/or with thickness 2mm) In: rated current referred to a room temperature of 40 ΔV : for calculations, see page 95 (*) PE 1 Standard version (*) PE 2 Extra earth - OPPER (*) PE 3 Extra earth - LMINM 54 SPER OMPT
50 130 SP SPER OMPT Technical data SP (3L+N+PE) N L1 L2 L3 PE OPPER Rated current I n [] asing overall dimensions L x [mm] 130x x x x x x x x x480 Operating voltage e [V] Insulation voltage i [V] Frequency f [z] 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Rated short-time current for three-phase fault (1 s) I W [k]rms llowable peak current for three-phase fault I pk [k] Rated short-time current for single-phase fault (1 s) I W [k]rms llowable peak current for single-phase fault [k] llowable specific energy for three-phase fault I 2 t [M 2 s] Phase resistance R 20 [mω/m] Phase reactance (50 z) X [mω/m] Phase impedance Z [mω/m] Phase resistance at thermal conditions R t [mω/m] Neutral resistance R 20 [mω/m] Phase impedance at thermal conditions Z [mω/m] Resistance of the protective conductor (PE 1) R PE [mω/m] Resistance of the protective conductor (PE 2) R PE [mω/m] Resistance of the protective conductor (PE 3) R PE [mω/m] Reactance of the protective conductor (50 z) X PE [mω/m] Resistance of the fault loop (PE 1) R o [mω/m] Resistance of the fault loop (PE 2) R o [mω/m] Resistance of the fault loop (PE 3) R o [mω/m] Reactance of the fault loop (50 z) X o [mω/m] Impedance of the fault loop (PE 1) Z o [mω/m] Impedance of the fault loop (PE 2) Z o [mω/m] Impedance of the fault loop (PE 3) Z o [mω/m] Zero-sequence resistance phase - N R o [mω/m] Zero-sequence reactance phase - N X o [mω/m] Zero-sequence Impedance phase - N Z o [mω/m] Zero-sequence resistance phase- PE R o [mω/m] Zero-sequence reactance phase - PE X o [mω/m] Zero-sequence Impedance phase - PE Z o [mω/m] cosϕ = cosϕ = Voltage drop factor with cosϕ = distributed load k [V/m/] -6 cosϕ = ΔV = k. L. I. e -6 [V] cosϕ = cosϕ = cosϕ = Weight (PE 1) p [kg/m] Weight (PE 2) p [kg/m] Weight (PE 3) p [kg/m] Fire load [kwh/m] Degree of protection IP Thermal resistance class of the insulating materials /F * /F * /F * /F * /F * /F * /F * /F * /F * Joule effect losses at rated current P [W/m] Min/Max mbient Temperature [ ] -5/50-5/50-5/50-5/50-5/50-5/50-5/50-5/50-5/50 * lass F thermal resistance (155 ) available on request - Regulations and conformity: IE/EN ; DIN VDE Product suitable for onstant/yclic Warm, humid climates: DIN IE 68 part 2-3; DIN IE 68 part Degree of protection: IP55; IPx7 carrying lines available with accessories, on request - Insulation and surface treatment of the conductors: Insulated conductors for the whole length, aluminum copper-plated and tin-plated - usbar casing material: 1.5mm galvanized steel plate, pre-painted or stainless steel (available, if required, with special paint and/or with thickness 2mm) In: rated current referred to a room temperature of 40 ΔV : for calculations, see page 95 (*) PE 1 Standard version (*) PE 2 Extra earth - OPPER (*) PE 3 Extra earth - LMINIM 55 IG POWER GENERL TLOGE
51 140 SP Technical Data Functional Earth ( clean earth ) SP5 (3L+N+PE+FE) FE N L1 L2 L3 PE LMINIM Rated current I n [] asing overall dimensions L x [mm] 140x x x x x x x x x480 Operating voltage e [V] Insulation voltage i [V] Frequency f [z] 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Rated short-time current for three-phase fault (1 s) I W [k]rms llowable peak current for three-phase fault I pk [k] Rated short-time current for single-phase fault (1 s) I W [k]rms llowable peak current for single-phase fault I pk [k] llowable specific energy for three-phase fault I 2 t [M 2 s] Phase resistance R 20 [mω/m] Phase reactance (50 z) X [mω/m] Phase impedance Z [mω/m] Phase resistance at thermal conditions R t [mω/m] Phase impedance at thermal conditions Z [mω/m] Neutral resistance R 20 [mω/m] Functional earthing resistance (FE) R 20 [mω/m] Functional earthing reactance (FE) X [mω/m] Resistance of the protective conductor (PE type 1) R PE [mω/m] Resistance of the protective conductor (PE type 2) R PE [mω/m] Resistance of the protective conductor (PE type 3) R PE [mω/m] Reactance of the protective conductor (50 z) X PE [mω/m] Resistance of the fault loop (PE 1) R o [mω/m] Resistance of the fault loop (PE 2) R o [mω/m] Resistance of the fault loop (PE 3) R o [mω/m] Reactance of the fault loop (50 z) X o [mω/m] Impedance of the fault loop (PE 1) Z o [mω/m] Impedance of the fault loop (PE 2) Z o [mω/m] Impedance of the fault loop (PE 3) Z o [mω/m] Zero-sequence resistance phase - N R o [mω/m] Zero-sequence reactance phase - N X o [mω/m] Zero-sequence Impedance phase - N Z o [mω/m] Zero-sequence resistance phase- PE R o [mω/m] Zero-sequence reactance phase - PE X o [mω/m] Zero-sequence Impedance phase - PE Z o [mω/m] cosϕ = Voltage drop factor with cosϕ = distributed load cosϕ = k [V/m/] -6 aduta di tensione con carico distribuito cosϕ = ΔV = k. L. I. e -6 [V] cosϕ = cosϕ = cosϕ = Weight (PE 1) p [kg/m] Weight (PE 2) p [kg/m] Weight (PE 3) p [kg/m] Fire load [kwh/m] Degree of protection IP Thermal resistance class of the insulating materials /F * /F * /F * /F * /F * /F * /F * /F * /F * Joule effect losses at rated current P [W/m] Min/Max mbient Temperature [ ] -5/50-5/50-5/50-5/50-5/50-5/50-5/50-5/50-5/50 * lass F thermal resistance (155 ) available on request - Regulations and conformity: In: rated current referred to a room temperature of 40 IE/EN ; DIN VDE ΔV : for calculations, see page 95 - Product suitable for onstant/yclic Warm, humid climates: DIN IE 68 part 2-3; DIN IE 68 part Degree of protection: IP55; IPx7 carrying lines available with accessories, on request - Insulation and surface treatment of the conductors: Insulated conductors for the whole length, aluminum copper-plated and tin-plated (*) (*) (*) - usbar casing material: 1.5mm galvanized steel plate, pre-painted or stainless steel PE 1 PE 2 PE 3 (available, if required, with special paint and/or with thickness 2mm) Standard version Extra earth - OPPER Extra earth - LMINIM 56 SPER OMPT
52 140 SP SPER OMPT SP Technical Data Functional Earth ( clean earth ) SP5 (3L+N+PE+FE) FE N L1 L2 L3 PE OPPER Rated current I n [] asing overall dimensions L x [mm] 140x x x x x x x x x480 Operating voltage e [V] Insulation voltage i [V] Frequency f [z] 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Rated short-time current for three-phase fault (1 s) I W [k]rms llowable peak current for three-phase fault I pk [k] Rated short-time current for single-phase fault (1 s) I W [k]rms llowable peak current for single-phase fault I pk [k] llowable specific energy for three-phase fault I 2 t [M 2 s] Phase resistance R 20 [mω/m] Phase reactance (50 z) X [mω/m] Phase impedance Z [mω/m] Phase resistance at thermal conditions R t [mω/m] Phase impedance at thermal conditions Z [mω/m] Neutral resistance R 20 [mω/m] Functional earthing resistance (FE) R 20 [mω/m] Functional earthing reactance (FE) X [mω/m] Resistance of the protective conductor (PE type 1) R PE [mω/m] Resistance of the protective conductor (PE type 2) R PE [mω/m] Resistance of the protective conductor (PE type 3) R PE [mω/m] Reactance of the protective conductor (50 z) X PE [mω/m] Resistance of the fault loop (PE 1) R o [mω/m] Resistance of the fault loop (PE 2) R o [mω/m] Resistance of the fault loop (PE 3) R o [mω/m] Reactance of the fault loop (50 z) X o [mω/m] Impedance of the fault loop (PE 1) Z o [mω/m] Impedance of the fault loop (PE 2) Z o [mω/m] Impedance of the fault loop (PE 3) Z o [mω/m] Zero-sequence resistance phase - N R o [mω/m] Zero-sequence reactance phase - N X o [mω/m] Zero-sequence Impedance phase - N Z o [mω/m] Zero-sequence resistance phase- PE R o [mω/m] Zero-sequence reactance phase - PE X o [mω/m] Zero-sequence Impedance phase - PE Z o [mω/m] cosϕ = cosϕ = Voltage drop factor with cosϕ = distributed load k [V/m/] aduta di tensione con carico distribuito cosϕ = ΔV = k. L. I. e -6 [V] cosϕ = cosϕ = cosϕ = Weight (PE 1) p [kg/m] Weight (PE 2) p [kg/m] Weight (PE 3) p [kg/m] Fire load [kwh/m] Degree of protection IP Thermal resistance class of the insulating materials /F * /F * /F * /F * /F * /F * /F * /F * /F * Joule effect losses at rated current P [W/m] Min/Max mbient Temperature [ ] -5/50-5/50-5/50-5/50-5/50-5/50-5/50-5/50-5/50 - Regulations and conformity: * lass F thermal resistance (155 ) available on request IE/EN ; DIN VDE In: rated current referred to a room temperature of 40 - Product suitable for onstant/yclic Warm, humid climates: ΔV : for calculations, see page 95 DIN IE 68 part 2-3; DIN IE 68 part Degree of protection: IP55; IPx7 carrying lines available with accessories, on request - Insulation and surface treatment of the conductors: Insulated conductors for the whole length, aluminum copper-plated and tin-plated (*) (*) (*) - usbar casing material: 1.5mm galvanized steel plate, pre-painted or stainless steel PE 1 PE 2 PE 3 (available, if required, with special paint and/or with thickness 2mm) Standard version Extra earth - OPPER Extra earth - LMINIM 57 IG POWER GENERL TLOGE
53 140 Double neutral technical data SP2N (3L+2N+PE) 2N L1 L2 L3 PE LMINIM Rated current I n [] asing overall dimensions L x [mm] 140x x x x x x x x x480 Operating voltage e [V] Insulation voltage i [V] Frequency f [z] 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Rated short-time current for three-phase fault (1 s) I W [k]rms llowable peak current for three-phase fault I pk [k] Rated short-time current for single-phase fault (1 s) I W [k]rms llowable peak current for single-phase fault I pk [k] Rated short-time protection current (1 s) I W [k]rms Protection circuit peak rated current I pk [k] llowable specific energy for three-phase fault I 2 t [M 2 s] Phase resistance R 20 [mω/m] Phase reactance (50 z) X [mω/m] Phase impedance Z [mω/m] Phase resistance at thermal conditions R t [mω/m] Phase impedance at thermal conditions Z [mω/m] Neutral resistance R 20 [mω/m] Resistance of the protective conductor (PE type 1) R PE [mω/m] Resistance of the protective conductor (PE type 2) R PE [mω/m] Resistance of the protective conductor (PE type 3) R PE [mω/m] Reactance of the protective conductor (50 z) X PE [mω/m] Resistance of the fault loop (PE 1) R o [mω/m] Resistance of the fault loop (PE 2) R o [mω/m] Resistance of the fault loop (PE 3) R o [mω/m] Reactance of the fault loop (50 z) X o [mω/m] Impedance of the fault loop (PE 1) Z o [mω/m] Impedance of the fault loop (PE 2) Z o [mω/m] Impedance of the fault loop (PE 3) Z o [mω/m] Zero-sequence resistance phase - N R o [mω/m] Zero-sequence reactance phase - N X o [mω/m] Zero-sequence Impedance phase - N Z o [mω/m] Zero-sequence resistance phase- PE R o [mω/m] Zero-sequence reactance phase - PE X o [mω/m] Zero-sequence Impedance phase - PE Z o [mω/m] cosϕ = cosϕ = Voltage drop factor with cosϕ = distributed load k [V/m/] aduta di tensione con carico distribuito cosϕ = ΔV = k. L. I. e -6 [V] cosϕ = cosϕ = cosϕ = Weight (PE 1) p [kg/m] Weight (PE 2) p [kg/m] Weight (PE 3) p [kg/m] Fire load [kwh/m] Degree of protection IP Thermal resistance class of the insulating materials /F * /F * /F * /F * /F * /F * /F * /F * /F * Joule effect losses at rated current P [W/m] Min/Max mbient Temperature [ ] -5/50-5/50-5/50-5/50-5/50-5/50-5/50-5/50-5/50 - Regulations and conformity: * lass F thermal resistance (155 ) available on request IE/EN ; DIN VDE In: rated current referred to a room temperature of 40 - Product suitable for onstant/yclic Warm, humid climates: ΔV : for calculations, see page 95 DIN IE 68 part 2-3; DIN IE 68 part Degree of protection: IP55; IPx7 carrying lines available with accessories, on request - Insulation and surface treatment of the conductors: Insulated conductors for the whole length, aluminum copper-plated and tin-plated (*) (*) (*) - usbar casing material: 1.5mm galvanized steel plate, pre-painted or stainless steel PE 1 PE 2 PE 3 (available, if required, with special paint and/or with thickness 2mm) Standard version Extra earth - OPPER Extra earth - LMINIM 58 SPER OMPT
54 140 SP SPER OMPT Double neutral technical data SP2N (3L+2N+PE) 2N L1 L2 L3 PE OPPER Rated current I n [] asing overall dimensions L x [mm] 140x x x x x x x x x480 Operating voltage e [V] Insulation voltage i [V] Frequency f [z] 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Rated short-time current for three-phase fault (1 s) I W [k]rms llowable peak current for three-phase fault I pk [k] Rated short-time current for single-phase fault (1 s) I W [k]rms llowable peak current for single-phase fault I pk [k] Rated short-time protection current (1 s) I W [k]rms Protection circuit peak rated current I pk [k] llowable specific energy for three-phase fault I 2 t [M 2 s] Phase resistance R 20 [mω/m] Phase reactance (50 z) X [mω/m] Phase impedance Z [mω/m] Phase resistance at thermal conditions R t [mω/m] Phase impedance at thermal conditions Z [mω/m] Neutral resistance R 20 [mω/m] Resistance of the protective conductor (PE type 1) R PE [mω/m] Resistance of the protective conductor (PE type 2) R PE [mω/m] Resistance of the protective conductor (PE type 3) R PE [mω/m] Reactance of the protective conductor (50 z) X PE [mω/m] Resistance of the fault loop (PE 1) R o [mω/m] Resistance of the fault loop (PE 2) R o [mω/m] Resistance of the fault loop (PE 3) R o [mω/m] Reactance of the fault loop (50 z) X o [mω/m] Impedance of the fault loop (PE 1) Z o [mω/m] Impedance of the fault loop (PE 2) Z o [mω/m] Impedance of the fault loop (PE 3) Z o [mω/m] Zero-sequence resistance phase - N R o [mω/m] Zero-sequence reactance phase - N X o [mω/m] Zero-sequence Impedance phase - N Z o [mω/m] Zero-sequence resistance phase- PE R o [mω/m] Zero-sequence reactance phase - PE X o [mω/m] Zero-sequence Impedance phase - PE Z o [mω/m] cosϕ = cosϕ = Voltage drop factor with cosϕ = distributed load k [V/m/] aduta di tensione con carico distribuito cosϕ = ΔV = k. L. I. e -6 [V] cosϕ = cosϕ = cosϕ = Weight (PE 1) p [kg/m] Weight (PE 2) p [kg/m] Weight (PE 3) p [kg/m] Fire load [kwh/m] Degree of protection IP Thermal resistance class of the insulating materials /F * /F * /F * /F * /F * /F * /F * /F * /F * Joule effect losses at rated current P [W/m] Min/Max mbient Temperature [ ] -5/50-5/50-5/50-5/50-5/50-5/50-5/50-5/50-5/50 - Regulations and conformity: * lass F thermal resistance (155 ) available on request IE/EN ; DIN VDE In: rated current referred to a room temperature of 40 - Product suitable for onstant/yclic Warm, humid climates: ΔV : for calculations, see page 95 DIN IE 68 part 2-3; DIN IE 68 part Degree of protection: IP55; IPx7 carrying lines available with accessories, on request - Insulation and surface treatment of the conductors: Insulated conductors for the whole length, aluminum copper-plated and tin-plated (*) (*) (*) - usbar casing material: 1.5mm galvanized steel plate, pre-painted or stainless steel PE 1 PE 2 PE 3 (available, if required, with special paint and/or with thickness 2mm) Standard version Extra earth - OPPER Extra earth - LMINIM 59 IG POWER GENERL TLOGE
55 Suggestions for the project development EXMPLE FOR QOTTION EK LIST: Rating.. 2. pplication: Transport Distribution No. of outlets Icc at the beginning of the line...k 4. Material: luminium opper 5. Degree of protection: IP55 (standard) 6. Painting: RL7035 (standard) Different RL colour on request 7. Neutral section: 0% SP (standard) 200% SP2N 8. Nominal ambient temperature: 40 (standard) Other on request 9. ttach usbar layout* Drawing Dwg file 60 SPER OMPT
56 SP SPER OMPT EKLIST TO E DONE DRING TE PROJET 1. Verify the measurements of the drawings, the correct position of the equipment (MV/LV transformer and LV switchboard enclosures 2. heck the availability of drawings required (transformer, switchboard board, etc.) 3. heck for the existence of unforeseen obstacles in the installation which could impede the run of the usbar (for example pipelines, ventilation and air-conditioning ducts). 4. gree upon who is responsible for providing the connection from the usbar to the other devices (MV/LV transformer and LV switchboards). Example of detail of the project Zucchini provides without charge, if required: The mechanical layout of theproject Study of the connections between the usbar and the transformer or between switchboard enclosures Suggestions for the type of fixing (floor, wall, ceiling ) Possibility of site measurement by qualified persons Telephone assistance during the entire installation stage by the Engineering Design Office. 61 IG POWER GENERL TLOGE
MISTRAL SYSTEM IMPACT 2
MISTRAL 25-40A SYSTEM 100-400A IMPACT 2 400-6300A Megabarre Group represents the perfect fusion of a global offer, a highly-qualified service and a great working efficiency. The certificated quality of
More informationZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR
ZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR The flexibility of the Zucchini MS range during planning and installation makes it ideal for frequently changing requirements in small to medium sized commercial
More informationTECHNICAL GUIDE 2011 SCP SUPER COMPACT. Busbar up to 5000A
TEHNIL GUIDE 2011 SP SUPER OMPT usbar up to 5000 2 Zucchini Super ompact SP busbar trunking systems: simple, safe, and flexible power. 3 3 4 SP USRS ONTENTS General features 6 Features of the line 12 Electric
More informationGROUP MEGABARRE IMPACT. 800A 5000A Abu Dhabi Edition
GROUP MEGABARRE IMPACT 800A 5000A Abu Dhabi Edition B U S B A R T R U K I G S Y S T E M GEERAL DATA TRUKIG ELEMETS COECTIO ELEMETS TAP-OFF UITS ACCESSORIES SUSPESIO UITS TECHICAL DATA ISTALLATIO ISTRUCTIOS
More informationUse RH covers when starting with a LH feed unit or when reaching the LH board. HIGH RATING
Aluminium 1000A 1250A 1600A 2000A 2250A 2500A 3200A 4000A 4500A R 95503111 95503131 95503131 95503141 95513111 95513131 95513131 95513141 95513151 L 95503211 95503231 95503231 95503241 95513211 95513231
More informationRCP IP68 RESIN BUSBAR TRUNKING GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE
RCP IP68 RESIN BUSBAR TRUNKING GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE IP68 RCP RESIN BUSBAR TRUNKING New resin busbar RCP ranging from 6 A to A and IP68 degree of protection,
More informationBusbar Trunking Assembly
Busbar Trunking Assembly 00A-600A : 000V Horizontal and Vertical applications Suitable for Reliable Power Distribution to: > industry > highrise buildings - transformer to switchboards - switchboards to
More informationReduction - RD. Sample Order: 2000A / 1600A, Aluminium, Bolt-on, IP 55, 4 conductors KXA B - RD17. Right Side Feeder "T" Sample Order: B
ELIE Standard omponents USR TYPE ODUTOR TYPE USR ODE PROTETIO DEGREE ODUTOR OFIGURTIO UTIZILTIO TYPE P Plugin / olton OMPOET Reduction Is use to change the busbar cross section. Reduction RD Reduced usbar
More informationMulti-conductor Lighting Busbar System A
ISO 9001 101 ENVIRONMENTAL MANAGEMENT SYSTEMS QUALITY AND www.eae.com.tr Akcaburgaz Mahallesi, 119. Sokak, No:10 34510 EsenyurtIstanbulTurkey Tel: +90 (212) 866 20 00 Faks: +90 (212) 886 24 20 IEC 604392
More informationIBAR (EMEA) LIMITED Castle Mills Aynam Road Kendal Cumbria LA9 7DE UK YEARS+ Established. t. +44 (0) e.
IBAR (EMEA) LIMITED Castle Mills Aynam Road Kendal Cumbria LA9 7DE UK 50 YEARS+ Established 966 t. +44 (0) 539 7206 e. sales@mardix.com www.resinbar.com A brand of IP68 Cast Resin Busbar System RESINBAR
More information50 YEARS+ A brand of the. IBAR (EMEA) LIMITED Castle Mills Aynam Road Kendal Cumbria LA9 7DE UK
IBAR (EMEA) LIMITED Castle Mills Aynam Road Kendal Cumbria LA9 7DE UK 50 EARS+ Established 966 t. +44 (0) 539 706 e. sales@mardix.com www.resinbar.com A brand of the IP68 Cast Resin Busbar System RESINBAR
More informationCable Management Solutions with DLP TM
DLP trunking system P. 374-375 Selection chart for DLP trunking system P. 397 Floor boxes & Under floor boxes Technical data P. 373 DLP U-PVC adaptable trunking system Cable Management Solutions with DLP
More informationLinear Motion and Assembly Technologies Aluminum Framing /07. Die-Cast Foundation Brackets 3-10 & 3-11
-0 Linear Motion and ssembly Technologies luminum Framing 91 500 1 /07 Section : Profile onnectors Overview One of the greatest strengths of the osch Rexroth structural aluminum framing system is the wide
More informationTotally Integrated Power SIVACON 8PS LI busbar trunking system siemens.com/li-system
An integrated solution for safe and efficient power supply Totally Integrated Power SIVACON 8PS LI busbar trunking system siemens.com/li-system Contents Totally Integrated Power 2 SIVACON 8PS busbar trunking
More information4.3 Section CONDUIT INSTALLATION ACCESSORIES. Thinking of the environment. Fixing accessories Coupling accessories
CONDUIT INSTALLATION ACCESSORIES Thinking of the environment We use only fully recyclable halogen-free thermoplastics, without harmful additives. No cadmium or asbestos in the colourants either. For total
More informationMedium power busbar trunking
Canalis KS (100 to 800 A) For high density distribution in industrial and commercial buildings Presentation 4 1 2 5 1 Run components 7 ratings : 100, 160, 250, 400, 500, 630 and 800 A 4 live conductors.
More information5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts
ALPHA AS Modular Distribution Boards /2 Introduction Unequipped Distribution Boards /4 Modular distribution boards / Add-on parts Assembly Kits for Unequipped Distribution Boards /6 8GK4 assembly kits
More informationSPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers
SPECIFICATION GUIDE ABB VACUUM CAST COIL DRY TRANFORMERS CONTENTS 1. General 1.1. Codes and standards 1.2. Service conditions 1.3. System characteristics 1.4. Documentation 2. Design and construction 2.1.
More informationBUSBAR TRUNKING SYSTEMS 25A-63A AB-E SERIES. The smartest way of power distribution.
BUSBAR TRUNKING SYSTEMS SERIES 25A-63A TABLE OF CONTENTS SERIES General Information 2-4 Project Information 5-6 Fittings Straight Lengths 7-8 Elbow Modules 8-9 Dilatation Module 9 Top Feed Module 10 End
More informationFuse Links NV/NH gg with Striker Pin Dimensions
D E I A 9,8 G J H l l Fuse Links Electrical characteristics Rated voltage U n Rated current I n reaking capacity U n Melting characteristic ertified In accordance with Dimensions according to Two versions
More information4/2 Introduction. Marshaling Boxes 4/8 8GK1 surface-mounting distribution boards
ALPHA 630 - DIN Floor- Mounted Distribution Boards /2 Introduction Unequipped Distribution Boards /5 8GK1 surface-mounting distribution boards, IP3 /6 8GK1 surface-mounting distribution boards, IP55 Marshaling
More informationLow-Voltage Power Distribution and Electrical Installation Technology
Busbar trunking system Configuration Manual 10/2011 Low-Voltage Power Distribution and Electrical Installation Technology Answers for infrastructure. SIVACON 8PS - Configuring with LX system Low-voltage
More informationSECTION PANELBOARDS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 24 16 PANELBOARDS SPEC WRITER NOTE: Delete between // --- // if not applicable to project. Also, delete any other item or paragraph not applicable in the section
More informationSafety switches with slotted hole lever
Safety switches with slotted hole lever Selection diagram C1 C C C4 C5 Straight slotted hole lever Slotted hole lever at the left Slotted hole lever at the right (without bend) Slotted hole lever at the
More informationLow-Voltage Power Distribution and Electrical Installation Technology
Busbar trunking system SIVACON 8PS - Planning with System LR Planning Manual 05/2012 Low-Voltage Power Distribution and Electrical Installation Technology Answers for infrastructure. About this documentation
More informationLBPLUS DATA. he new busbar unking system for LIGHTING MANAGEMENT. Range
LBPLUS DATA The he new busbar trunking unking system for LIGHTING MANAGEMENT, the new busbar conceived for distribution and lighting in the service sector, which integrates a BUS that can be used for Lighting
More informationBusbar and Modular Wiring Systems
Chapter 11 Busbar and Modular Wiring Systems 11.1 BUSBAR SYSTEM The wide range of busbar system is available and can be used for single or three-phase distribution to many types of applications ranging
More informationClamping devices 521
Clamping devices 521 522 Product overview Clamping devices Adjustable straps K0001 Hook clamps K0012 Goose-neck straps with long slot K0002 Page 526 Hook Clamps with collar K0013 Page 535 Equipped clamps
More informationSINGLE-PHASE VSV SWITCH
May 2006 Supercedes: March 2006 SINGLE-PHASE VSV SWITCH INSTALLATION AND OPERATING MANUAL Table of Content: Page I. General...2 II. Specifications...2 III. Installation...2 IV. Maintenance...4 V. VSV Power
More informationIP68 RCP RESIN BUSBAR TRUNKING FOR POWER DISTRIBUTION POWERED BY SPECIALISTS
IP68 RCP RESIN BUSBAR TRUNKING FOR POWER DISTRIBUTION POWERED BY SPECIALISTS IP68 RCP RCP RESIN busbar trunking resin busbar is the latest addition to the Zucchini range. With an ingress protection rating
More information2/2 Introduction. Unequipped Distribution Boards 2/5 8GK1 surface and flush-mounting distribution boards
Siemens AG 010 ALPHA 160 - DIN Wall-Mounted Distribution Boards / Introduction Distribution Boards with Built-In Distribution Board Panels /4 8GK1 surface and flush-mounting with quickassembly kits Unequipped
More information10. Mini Coax Connectors
. Connectors The allows multi-pole coaxial data transmission for board-to-board, cable-to-board and cable-to-cable applications with protection up to IP 65 / IP 67. At the same time, applications up to
More informationPURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS
PURCHASE SPECIFICATIONS OF 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS SPECIFICATION NO. : OR12423 REVISION NO. : Rev 00 DATE : 01.03.2011 DISTRIBUTION : PI - 4 copies O/C - 1 copy PREPARED BY
More informationLow-Voltage Power Distribution and Electrical Installation Technology
Busbar trunking system Installation Manual 06/2011 Low-Voltage Power Distribution and Electrical Installation Technology Answers for infrastructure. SIVACON 8PS - Installation with LX system Low-voltage
More informationPowerlink Plus Technical
CABLE MANAGEMENT mkelectric.co.uk TECHNICAL SPECIFICATION ELECTRICAL VOLTAGE RATING 63A, 250V a.c. VOLTAGE DROP L to N = 3.47 mv/a/metre run L to E = 3.47 mv/a/metre run N to E = 3.47 mv/a/metre run EARTH
More informationJunction boxes. Surface mounting - IP44 - IP55 - IP56 TECHNICAL CHARACTERISTICS
Junction boxes Surface mounting - IP44 - - IP56 TECHNICAL CHARACTERISTICS Technical specifications 3 models with cable outlets and snap fixed cover (IP44 according to Standards EN 60529) 7 models with
More informationElectrical Power Distribution Low-Voltage Systems SIVACON 8PS busbar trunking systems Installing with LI system
Introduction 1 Application planning 2 Electrical Power Distribution Low-Voltage Systems SIVACON 8PS busbar trunking systems Installation Manual Installation 3 Commissioning 4 Service and maintenance 5
More informationComponents for low voltage panel boards
omponents for low voltage panel boards UTUMN UTOMTION N ONTRO EETRI ISTRIUTION OEM Products catalogue Ω OK - Unipolar terminal locks PROUTS Ω OK IT 80-11 IT 80-15 G IT 80-7 W IT-S IN35 TEHNI FETURES 31
More informationTechnical data. Contact material: with double break or 2 NC contacts Switching system: A IEC snap action with positive break NC contacts
Emergency pull-wire switches ZS 71... NA Technical data Contact variations * 63 mm for version 200 N pre-tensioning force To EN 418/IEC 60947-5-5 Metal enclosure 2 contacts Integrated emergency-stop button
More informationCompliant to DOE 10, CFR Part 431 (effective as of January 1 st, 2016)
Typical Specification 1.2kV Class Energy Efficient Dry-Type Distribution Transformers Compliant to DOE 10, CFR Part 431 (effective as of January 1 st, 2016) Canada 595 Southgate Drive Guelph, Ontario N1G
More informationBrown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS
SECTION 16461C - DRY TYPE TRANSFORMERS PART 1 - GENERAL 1.1 This section includes design and performance requirements for dry-type transformers rated for use on secondary distribution systems rated 600
More informationCentral Inverter SUNNY CENTRAL 200 / 250 / 250HE / 350
Central Inverter SUNNY CENTRAL 200 / 250 / 250HE / 350 Installation Guide SC20_25_35-IEN094521 98-4004821 Version 2.1 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Notes on this Manual..............................
More information(1,5 modules per pole)
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 25kA 80A to 125A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationSB 50 Connectors - up to 120 amps
Connectors - up to 120 amps Based off the design pioneered by Anderson in 1953, APP s two pole SB connectors set the standard for DC power distribution and battery connections. connectors feature a one
More informationThe series terminals are state of the art based on technical enhancements, changes in power engineering, their applications and properties.
w TERMINALS SERIES IK6 GENERAL INFORMATION The series terminals are state of the art based on technical enhancements, changes in power engineering, their applications and properties. 402 Since series terminals
More informationSECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS
SECTION 270536 - CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationTECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES
INDEPENDENT POWER TRANSMISSION OPERATOR S.A. TNPRD/ SUBSTATION SPECIFICATION & EQUIPMENT SECTION October 2014 TECHNICAL DESCRIPTION 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES I. SCOPE This
More informationRaised Floor system LIMOGES Cedex. Phone : Fax :
87045 LIMOGES Cedex Phone : 05 55 06 87 87 Fax : 05 55 06 88 88 Raised Floor system CONTENTS PAGES 1.Range 1 to 3 2.Installation process 4 to 10 3.Products détails 11 to 22 4.Technical characteristics
More informationT e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker
T e c h n i c a l C a t a l o g u e MCCB Moulded Case Circuit Breaker contents general overview... 2 feature - company profile and certifications... 6 MCCB - NF series circuit breaker, double repulsion
More informationInstallation Instructions
Installation Instructions For 4 foot / 1.2m Diameter Ultra-high Performance Antenna Model ADxxG-4-T2 Before Installation, please read the instructions carefully. This instruction guide covers the installation
More informationWanco Electric & Machinery Pte Ltd. Cable Management Systems. Cable Trunking
Wanco Electric & Machinery Pte Ltd Cable Management Systems Cable Trunking About Wanco Wanco Electric and Machinery Pte Ltd is the leader in electrical construction materials. Through continued support
More informationNemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4
I N D U S T R I A L rev. A- INSTALLATION INSTRUCTIONS *PENDING* E77827 E77827 APPLICATION MR3 & MR6 Luminaires are suitable for use in the following areas as defined by the National Electrical Code (NEC)
More informationOptiLine 45 Floor boxes
OptiLine 45 Floor outlet boxes P89490 Type Colour Dimensions A/B/C (mm) Qty per pack Ref. No. Floor outlet box including mounting frames for Altira, trim frame with four quick-fix devices and lid with
More informationInigo Sconce INSTALLATION INSTRUCTIONS P _2_A 1 of 5
P31321 1 of 5 Thank You For Choosing Kallista We appreciate your commitment to Kallista quality products. Please take a moment to review this manual before you install your Kallista product. If you encounter
More information10. Mini Coax Connectors
. Connectors The allows multi-pole coaxial data transmission for board-to-board, cableto-board and cable-to-cable applications with protection up to IP65 / IP67. At the same time, applications up to 2.5
More informationPIPE/CONDUIT SUPPORTS
PIPE/CONDUIT SUPPORTS Pipe/Conduit Clamps...102-105 Unicushion... 106 Pipe & Tubing (Cush-A-Clamp ) Clamps...107-110 Pipe Hangers... 111 Pipe Rollers...111-112 Pipe Brackets... 113 Reference Tables...114-120
More informationCurrent / residual current and voltage transformers. Current / residual current and voltage transformers
Current / residual current and voltage transformers Current / residual current and voltage transformers 1 Overview Current transformer overview DIN rail current transformer with fuse Current transformer...
More informationDRIVIA cabinets LIMOGES Cedex France 1. DESCRIPTION, USE 3. DIMENSIONS 2. RANGE, CAT. NO. EQUIVALENCE TABLE
87045 LIMOGES Cedex France Tel: (+33) 05 55 06 87 87 Fax: (+33) 05 55 06 88 88 DRIVIA cabinets CONTENTS NTS PAGES 1. Description, use....1 2. Range, equivalence table...1 3. Dimensions...1 4. General characteristics...2
More informationPremoulded cable joint SMPGB
Premoulded cable joint SMPGB 362-420 Premoulded for safe and easy installation Active pressure Reliable Joint bodies routinetested according to IEC before delivery Bolt connector technology Compact joint
More informationSINGLE-PHASE VSV SWITCH
Revision: September 2009 Supersedes: August 2007 SINGLE-PHASE VSV SWITCH INSTALLATION AND OPERATING MANUAL Table of Content: Page I. General...2 II. Specifications...2 III. Installation...3 IV. Maintenance...5
More informationINSTALLATION INSTRUCTIONS
AUTOMOTIVE PRODUCTS, INSTALLATION INSTRUCTIONS PLATINUM 4 OVAL STEP BAR (90 BENT END) APPLICATION: 2010-2015 Dodge Ram 2500/3500 Mega Cab PART NUMBER: 21-3570, 21-3575, 23-3570, 23-3575, 25-3570, 25-3575,
More informationMC CHANGER CABINET INSTALLATION INSTRUCTIONS
8M00356 REV. 10 www.standardchange.com 1-800-968-6955 Technical Phone Support is from 8:00AM to 7:30PM E.S.T., Monday-Friday Walk-in Service is from 8:00AM to 4:30PM E.S.T., Monday-Friday Parts Department
More informationVarioSole SE. Installation instructions
VarioSole SE Installation instructions INTRODUTION Product Information VarioSole is a universal, easy to install system for the mounting of framed PV modules on pitched roofs with a roof pitch between
More informationThe shield (screen) connecting system from WAGO offers high electrical and mechanical safety for very flexible applications.
The shield (screen) connecting system from WAGO offers high electrical and mechanical safety for very flexible applications. Shield (Screen) Connecting System VOLUME 1 Shield (screen) connecting system
More informationINTELLIMETER REGISTER
INTELLIMETER REGISTER MODEL RG2 INSTALLATION AND CONNECTIONS INSTALLATION MANUAL WARNING: Any work on or near energized metering equipment can present a danger of electrical shock. All work on these products
More informationRosemount 5408 and 5408:SIS Level Transmitters
Quick Start Guide 00825-0100-4408, Rev AD March 2018 Rosemount 5408 and 5408:SIS Level Transmitters Cone Antenna Quick Start Guide March 2018 1 About this guide This Quick Start Guide provides basic guidelines
More informationInstallation Instructions
4 3 2 Installation Instructions Self Cleaning Radiant Electric Slide-In Range JSP46, JSP56, JS966 If you have questions, Call 800-GE-CARES or visit our website at: www.geappliances.com Skill Level: High
More informationPowerpole Connectors - PP75: up to 120 Amps
Powerpole Connectors - PP75: up to 120 Amps PP75 with Mounting Wings PP75 series Powerpole housings can be used for wire-to-wire, wire-to-board, and wire-to-busbar applications. Wire sizes from #16 AWG
More informationCast resin transformers HARMONY TM
Cast resin transformers HARMONY TM HARMONY TM the optimum solution for higher performance At a time when we are all seeking to preserve our way of life, the production of equipment whilst ensuring safety
More informationSIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A
The solution for Load break switches > Power distribution. sircm_100_a_1_cat Rotary switch SIRCO M 3 x 100 A Strong points > Total integration. > Wide range of accessories. > Upgradeability. > Compliance
More information10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units
BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells
More informationSignal converter for electromagnetic flowmeters
Quick Start Signal converter for electromagnetic flowmeters Electronic revision: ER 3.0.xx The documentation is only complete when used in combination with the relevant documentation for the flow sensor.
More informationFM series position switches
FM series position switches Selection diagram 0 08 0 A A 0 A 0 External rubber gasket External rubber gasket External rubber gasket External rubber gasket 0 69 Round rod, stainless steel Square rod Glass
More informationInstallation Tools. Pipe Cutters for steel and cast iron pipes 598. Deburring Reamer / for stainless steel pipes 600. for copper pipes 602
596 597 Installation Tools Pipe Cutters for steel and cast iron pipes 598 Pipe Cutters / Pipe Deburring Reamer for stainless steel pipes 600 Pipe Cutters / Pipe Deburring Reamer / Calibrating Tool for
More informationStandard Pole Mount Parabolic Antenna Mounting Instructions 3 ft. (90cm) & 4 ft. (120cm)
495 R Billerica Ave. N. Billerica, MA 01862 USA Tel: (978) 459-8800 Fax: (978) 459-3310 / 8814 www.radiowavesinc.com email: sales@radiowavesinc.com Standard Pole Mount Parabolic Antenna Mounting Instructions
More informationTR FI ES MA GM MK TN EG AZ IQ SY SA AE YE MZ TAP CHANGERS TYPE MHF IV
TR FI ES MA GM MK TN EG AZ IQ SY SA AE YE MZ TAP CANGERS TYPE MF IV GENERAL SPECIFICATION These tap changers are available in one, two or three phase applications. The shaft length is variable. Connection
More informationSection five. Connection systems. Isobar 4 Evo MCB pan assemblies Mulitclip busbar and Polybloc 126. Comb busbars 127
Connection systems Section five Isobar 4 Evo MCB pan assemblies 122 1 Mulitclip busbar and Polybloc 126 Comb busbars 127 Terminals and installation accessories 128 129 121 Isobar 4 Evo MCB pan assemblies
More informationHARAX. Contents Technical characteristics circular connector with HARAX rapid termination 50.02
Contents Page Technical characteristics circular connector with rapid termination 50.02 Circular connector M8/M12 with rapid termination... 50.05 Han M12 panel feed-through... 50.08 Han M12 pcb adapter...
More informationSPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)
SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA) 0.415/33kV DESIGN AND CONSTRUCTION General 1. The transformer shall be three phase, oil immersed type, air cooled, core type, outdoor
More informationIsolating Spark Gaps. Isolating spark gaps at an additional earth ring conductor. Isolating spark gaps for Ex zones
Isolating Spark Gaps Isolating spark gaps at an additional earth ring conductor Isolating spark gaps for Ex zones 187 Protective Spark Gaps For use at roof supports for overhead lines For indirect connection
More informationPowerpole Connectors - PP75: up to 120 Amps
Powerpole Connectors - PP75: up to 120 Amps PP75 with Mounting Wings PP75 series Powerpole housings can be used for wire-to-wire, wire-to-board, and wire-to-busbar applications. Wire sizes from #16 AWG
More informationMichigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE
PAGE 262400-1 SECTION 262400 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationCONTINUING EDUC ATION
3 CONTINUING EDUC ATION FOR WISCONSIN ELECTRICIANS 2017 NEC Article 250 2 Hours WISCONSIN CONTRACTORS INSTITUTE N16 W23217 Stone Ridge Drive Suite 290 Waukesha, WI 53188 262-409-4282 www.wcitraining.com
More informationInstallation Manual. Arc Chamber
Installation Manual Arc Chamber Installation Manual Introduction Administrative data Issue number: 6082940 G01 01 Date of issue: 25-03-2013 2 Arc Chamber Installation Manual 6082940 G01 01 March 25th 2013
More informationNeutral Earthing. For permanent or temporary neutral earthing in HV systems
Neutral Earthing Resistors RESISTORS For permanent or temporary neutral earthing in HV systems For continuous or temporary low-resistance neutral grounding in medium voltage systems Neutral point connection
More informationSECTION CABLE TRAYS
SECTION 16139 CABLE TRAYS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,
More informationALPHA DIN Wall-Mounted. Distribution Boards
Siemens AG 008 ALPHA 160 - DIN Wall-Mounted Distribution Boards / Introduction Distribution Boards with Built-In Distribution Board Panels /4 8GK1 surface and flush-mounting with quick-assembly kits Unequipped
More informationPowerpole Connectors - PP75: up to 120 Amps
Powerpole Connectors - PP75: up to 120 Amps PP75 with Mounting Wings PP75 series Powerpole housings can be used for wire-to-wire, wire-to-board, and wire-to-busbar applications. Wire sizes from #16 AWG
More informationCanalis KS. Contents. Presentation. Description. Catalogue numbers Dimensions. Installation
Contents Canalis KS Index 3 Introduction 8 Design guides and characteristics 29 Canalis KDP 57 Canalis KBA and KBL industrial luminaires 85 Canalis KBB 113 Canalis KN 139 Presentation Canalis KS 176 For
More informationAssembly Instructions
InTandem Table System November 20 InTandem Table System - Worksurface #4 x/" 4 wood screw power beam Tools Provided T-0 Extended Torx Driver T-25 Torx Driver Additional Tools Required Soft protective
More informationOperating tools. with partially insulated shaft Type 1, 2 and 3 in set
Accessories 40 Accessories 41 Operating Tools 42 45 Operating Tools WINSTA 46 47 Disconnection Tools 48 Cable Strippers 500 Wire Strippers 501 Cable Cutters 502 Crimping Tools 502 503 Test and Measurement
More informationSBS Connectors - up to 110 amps
Connectors - up to 1 amps NEW 75G 75X Wire to Wire The patented connector family is designed to provide high power in a compact ergonomic housing with protection against accidental contact with live circuits.
More informationSBS Connectors - up to 110 amps
SBS Connectors - up to 11 amps SBS 75G SBS 75X Wire to Wire The patented SBS connector family is designed to provide high power in a compact ergonomic housing with protection against accidental contact
More informationWind Direction Transmitter - compact - GMR, analogue output xxx xxx
THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021488/06/09 Wind Direction Transmitter - compact - GMR, analogue output - 4.3129.60.xxx 4.3129.80.xxx
More informationINSTALLATION, OPERATION AND MAINTENANCE GUIDE
INSTALLATION, OPERATION AND MAINTENANCE GUIDE FOR INDOOR/OUTDOOR SINGLE PHASE ENCAPSULATED TRANSFORMERS Indoor/Outdoor Encapsulated Transformers The pictures used in this guide are only a representation
More informationOperating instructions. Fine boring head Ø3-88 with digital display
Operating instructions Fine boring head Ø3-88 with digital display English 1. Basic safety information Before first use, please read the operating instructions carefully. These provide important safety
More informationDLP mini trunking. DLP U-PVC trunking system mini-trunking system. DLP U-PVC trunking system and accessories 80 x 50. Comfortable implementation
DLP mini trunking Cable-grip It makes the installation easier and faster by containing all the wires inside the trunking body before the cover is clipped Comfortable implementation During installation,
More informationGLS A GLS 15
GLS 25-40-63A GLS 15 GLS Graziadio Busbar Graziadio have been making busbar in Italy since 1959. Originally founded by Antonio Graziadio. The company continued to expand its sales and product ranges within
More informationTrunkingxxxxxx. in aluminium. Industrial Catalogue
93 Trunkingxxxxxx in aluminium Industrial Catalogue 151 TRUNKING 93 IN LUMINIUM Trunking 93 in aluminium To mount switches and sockets in environments requiring neat finishing Free choice of switches and
More informationPluggable connection describes the method used to connect an external conductor to a PCB, via a terminal connector and header
Pluggable PCB terminals and headers Pluggable connection describes the method used to connect an external conductor to a PCB, via a terminal connector and header System features plug in system is simple
More information