Harmonic Distortion Levels Measured at The Enmax Substations

Size: px
Start display at page:

Download "Harmonic Distortion Levels Measured at The Enmax Substations"

Transcription

1 Harmonic Distortion Levels Measured at The Enmax Substations This report documents the findings on the harmonic voltage and current levels at ENMAX Power Corporation (EPC) substations. ENMAX is concerned about the harmonic impact of future HVDC converters to be implemented close to its substations. The U of A team initiated this project to help addressing the concern. The approach is to measure, analyze and compare the harmonic currents and voltages at substations close to the future converter stations before and after the HVDC energization. Harmonic voltage and current field measurements were carried out during a one-week period in August 2011 at several ENMAX substations. This is the first time to collect the data. Similar measurements are planned for next year and thereafter. The collected data have been analyzed and presented through typical PQ indices and under different perspectives in order to facilitate comparison with future field measurements. The results include the daily profiles as well as the statistical distributions of the harmonic voltage and current at both phase and sequence domains.

2 Wire to Earth Voltage Comparative Analysis for Underbuilt Circuits Power line faults create the ground potential rise (GPR) on both the neutral and shield conductors when the transmission lines and distribution lines are built on the same structures. This study analyzes and compares the safety impacts of T- line faults and distribution line faults in the joint structures. First, the GPR mechanisms are illustrated and approximate formulas are established to describe the GPR characteristics. This project presents results on the GPR at the multigrounded neutral points of a distribution line and at the multi-grounded shield points of a transmission line where the distribution line is installed below a transmission line in the same tower structure. The GPR results of such a configuration are compared to those associated with common single circuit configurations. The results are obtained through extensive analytical studies and computer simulations. It was found that the under-built multi-grounded (MGN) distribution line does not increase the shield potential rise (SPR) of the corresponding transmission line when a distribution line is added. In comparison to the neutral potential rise (NPR) produced by a distribution line fault, the MGN neutral points will generally experience higher NPR when a fault occurs in the overbuilt transmission line.

3 Truck Grounding Issues Investigation A utility truck working under power lines may experience several safety risks, with the touch voltages produced by accidental contacts with energized lines being the primary concern. Utility companies have used a few grounding schemes to reduce these risks. The representative schemes are (1) ungrounding the truck, (2) bonding the truck to a temporary rod1, (3) bonding the truck to a system rod (i.e., the grounding point of the system neutral), and (4) bonding the truck to the system neutral. Each scheme involves its own work procedure, but no scheme can guarantee complete safety. As a result, utility companies in North America do not agree about which grounding scheme can lead to the best practice. In order to help the Alberta utility companies to make an informed decision on this subject, the Alberta Power Industry Consortium established a project to investigate the truck-grounding issues. The objective is to clarify and quantify the safety risks associated with the different truck-grounding schemes. It is hoped that the project findings will provide a technical background and support to the committees involved in establishing safe working practice. To fulfill the above objective, the research has been approached from the following three aspects: (a) options to increase worker safety, (b) quantitative assessment of the other concerns associated with different grounding schemes, and (c) comparing different grounding schemes. Through a complete study, this project has identified four safety options for utility companies to consider: 1) grounding (grounding to the system neutral (or rod), or no grounding at all), 2) barricading, 3) using an isolation mat, and 4) wearing insulating boots/gloves. By combining the above four safety options, all the possible safety packages for consideration by utility companies have been provided. 1 Temporary rod in this research refers to any grounding rod that is not connected to a multi-grounded neutral conductor. In other words, if there is no neutral in a feeder, all grounding rods are referred as temporary rod although they may exist permanently in the system. The electric performance of such rods is similar to the temporally created isolated rods.

4 Measuring the Supply System Impedance Parameters The equivalent circuit parameters of a power supply system such as the shortcircuit impedance are important data for both power supply authorities and industrial customers. The parameters have several applications. They are used to calculate the short circuit currents and to verify models of power system networks. The data are also needed for VAR compensator and harmonic filter designs to avoid creating resonance conditions. This project proposes a new method for online tracking of power system impedance parameters, which include the positive and zero sequence impedances and the harmonic impedances. The algorithm can be implemented into the power monitors widely available in load serving substations. The proposed algorithm is independent of load models and does not require synchronized data. So it overcomes the shortcomings of existing methods. Furthermore, practical implementation issues are addressed in the project and the proposed method has been verified using computer simulations, experimental studies, and several field measurements.

5 Measuring the Load Model Parameters The loads in power systems play an important role in power system planning, control and stability analysis. Having reliable and accurate models of the loads is essential for the purpose of designing automatic control systems and optimization of their configuration. Obtaining detailed and accurate models of power system loads can be a more complicated task than modeling other power system components, such as a synchronous machine. The reason is the large number of different loads, such as lighting, motor load heating, etc. and the complexity and random nature of their composition. The accurate load modeling has been a challenging problem for power system engineers for decades, especially in the deregulated market environment. Regarding the importance of the issue two basic approaches have been proposed in literature to model the composite loads in power system studies, namely, component-based and measurement-based. The component-based approaches build up the load model from information on the behaviors of all the individual components and load components of a particular load bus. The componentbased approach has the disadvantage of requiring performance of an extensive survey to collect load composition information, but, after deregulation, transmission system planners may not be able to access such information. The measurement-based approach involves installing measurement and data acquisition devices at various load buses to determine model structures and model parameters. They have the obvious advantage of obtaining data directly from the actual system. As well, these techniques can directly measure actual load behaviors and the parameters for the measurement-based load modeling approach can be easily updated when the load characteristics change. This project proposes a new method for online measurement and monitoring of power system load model parameters. The advantage of the proposed algorithm is the simple implementation and its ability to be applied for real-time monitoring of load parameters. Furthermore, practical implementation issues are addressed in the project and the proposed method has been verified using several field measurements. Details are omitted here due to patent filing.

6 Techniques and Software for Harmonic Source Detection in Power Systems There are many harmonic loads in a given distribution or sub-transmission system. These loads typically have comparable sizes and are scattered all over the system. Identifying loads that actually causes a reported harmonic problem has become an increasingly important task for utility power quality management. Unfortunately, there are no viable techniques that can pinpoint which customers cause harmonic distortions problem at a specific location of a system. This report presents a data-based method and associated technique for determining the individual harmonic impact of multiple harmonic-producing loads scattered in a power system. The report defines the problem and proposes a harmonic impact index to theorize the problem. It then presents a statistical inference based method to estimate the index. The data required for this analysis are the harmonic voltage and current magnitudes continuously collected by existing power quality monitors. To facilitate technology transfer to the consortium members, this method is implemented in a software package. A tutorial of the software and two application examples are provided in the report. The characteristics of the proposed method are also investigated through sensitivity and case studies. Finally, some notes about single-point applications of the proposed method are discussed.

7 Survey of High Impedance Fault Detection Techniques High Impedance Faults (HIF) usually occur at primary network level in electrical distribution systems. They can be described as those faults which do not draw sufficient current to be recognized and cleared by the over-current devices in common use in the utility industry. Research on high impedance fault detection has been conducted for decades. However, a complete solution has not yet been found. Not only is the current too small, but also because distinguishing high impedance faults from normal operations are very complicated as various normal operations unfortunately create the similar transient as HIF. The development of high impedance faults detection techniques are reviewed in this paper while individual techniques are analyzed. Those techniques based on voltage and current measurement can be classified into time domain and frequency domain algorithms. However, it is realized that so far no single detection algorithm could reliably identify a majority of HIF faults. Moreover, no single detection technique could both protect the public from the dangers of a downed conductor and minimize unnecessary power outages from false trips. A Composite system with multiple fault detection algorithms is a solution to overcome the limitations and disadvantages of single algorithms. The features of a composite system are introduced and the decision logic is analyzed. Moreover, alternative solution including mechanical technique and remote techniques are presented. Finally, possible improvements are proposed at the end of this report.

8 Substation GPR Transfer to Feeder Neutral Points The objective of this project is to investigate the neutral potential rise (NPR) of the MGN feeders due to short-circuit within substation boundaries. Analytical studies are performed to illustrate how the neutral potential rise (NPR) arises due to substation GPR. The NPR transfer to the downstream loads is estimated by establishing the simplified equations. The effects of system arrangements as well as the impact of the multi grounded neutral parameters are shown through case study results. The main findings of the report can be summarized as follows: The mechanisms involved in the GPR production are the same for the T- side faults and for the D-side faults and it is independent of the fault location in the substation. The NPR at the grounding points of MGN increases with the increase in neutral grounding resistances or grounding intervals. The neutral length has significant impact of the NPR profile, the shorter the neutral length; the higher will be the NPR at its end. However, the maximum NPR will be affected only slightly The grounding resistance of the first load downstream of the substation will affect the transferred NPR to this point, especially when the neutral is 2 km or less. In summary, general models for estimating the substation GPR and the maximum NPR have been established. This study is also applicable for the system where a multi-grounded conductor (shield, neutral, etc) is extended from the substation. Furthermore this study can be generalized for any number of feeders (single or multiple parallel feeders).

9 Measurement and Analysis of Harmonics in Residential Distribution Feeders Distribution system harmonic study was traditionally focused on the analysis of networks with dominant harmonic sources at known locations. They are usually associated with large individual industrial loads. With the proliferation of the harmonic producing loads, such as computers and variable speed drives, the harmonic sources become more and more randomly distributed into all over the network. Nowadays, every residential house could be a small harmonic source. And the collective effect of those distributed harmonic source has been of a great interest and a significant power quality concern. It can be summarized into two features: 1) those harmonic sources are usually random and small. 2) they are dispersed into everywhere through the whole distribution system. According to these characteristics, traditional harmonic analysis and mitigation methods may not be applicable anymore. It is urgent to understand the mechanism of harmonics build up in residential feeders whose loads are essentially distributed harmonic sources, and furthermore propose a system-wide harmonic analysis method and new strategy to design a novel filter to handle this kind of problem. This has become a new challenge to harmonic area. This project is one of the projects sponsored by the Alberta Power Industry Consortium. It first comes along with the telephone interference problems found in some residential neighborhoods in Edmonton, Canada. Month-long measurement has been carried out. These valuable measurements data helps to understand the harmonic behavior in the new circumstance, eventually, the corresponding theory and strategy to interpret and resolve this new problem will be developed.

10 Determining Acceptable AIES System Restoration Island Synchronizing Parameters This project investigates the main technical issues associated with the resynchronization of islanded Alberta Integrated Electric System (AIES). It determines if the current synchronization relay settings are adequate and recommends changes if required. Through a series of analytical and simulation studies, the impact of each synchronization parameter (voltage magnitude, phase angle and frequency differences at the synchronization points) on generators and overall system performance has been identified. The study further established analytical methodologies for interpreting the simulation results by revealing the nature and mechanism of the synchronization disturbances. Synchronization protection settings for AIES are recommended. One of the findings is that the generator-system synchronization produces the highest transients on the generators in comparison with the island-island synchronization cases when same synchronization criteria are used. The implication is that if one adopts the relay settings of generator-system synchronization to island-island synchronization, the impact of the synchronization transients on the generators will be less than that produced by the generator-system synchronizations.

11 Guide for Utility Motor Starting Planning The power quality impact of motor starting is a concern to utility companies. This concern is especially important in Alberta due to the presences of a large number of industrial facilities and the relatively long distribution lines. Although there are various ways to reduce the impact of motor starting, almost all of the solutions need to be planned and designed before the motor and its facility are connected to the system. Furthermore, new power quality standards such as the IEC flicker meter are gaining acceptance and it has become necessary to consider these standards when conducting the motor starting planning studies. The objective of this report is to provide technical information to support the motor starting planning study from the utility s perspective. The report attempts to address all key issues involved in the study and to provide practical ways for efficient motor starting impact assessment. The topics covered by this report include 1) power quality issues associated with motor starting, 2) customer and utility side solutions to the motor starting problems, 3) methods for motor starting study and 4) practical tools for quick screening of motor starting problems. These practical tools, called motor starting guideline charts, are developed according to the latest IEEE power quality standards. It helps a planning engineer quickly estimate if a motor installation can cause voltage sag or voltage flicker problems. He or she can then decide if detailed motor starting study is required.

UNIT-4 POWER QUALITY MONITORING

UNIT-4 POWER QUALITY MONITORING UNIT-4 POWER QUALITY MONITORING Terms and Definitions Spectrum analyzer Swept heterodyne technique FFT (or) digital technique tracking generator harmonic analyzer An instrument used for the analysis and

More information

New Methods to Mitigate Distribution System Harmonics

New Methods to Mitigate Distribution System Harmonics Alberta Power Industry Consortium 214 Power & Energy Innovation Forum New Methods to Mitigate Distribution System Harmonics By Wilsun Xu Power Disturbance & Signaling Research Lab November 5, 214 Outline

More information

Education & Training

Education & Training Distribution System Operator Certificate This program provides you with a proficient working knowledge in modern electric power distribution systems. These four classes are designed to walk students through

More information

Power Quality, Earthing And Bonding Oct $4,250 Dubai, UAE. In any of the 5 star hotels. The exact venue will be informed once finalized.

Power Quality, Earthing And Bonding Oct $4,250 Dubai, UAE. In any of the 5 star hotels. The exact venue will be informed once finalized. Training Title POWER QUALITY, EARTHING AND BONDING Training Duration 5 days Training Date Power Quality, Earthing And Bonding 5 04 08 Oct $4,250 Dubai, UAE In any of the 5 star hotels. The exact venue

More information

Reliability and Power Quality Indices for Premium Power Contracts

Reliability and Power Quality Indices for Premium Power Contracts Mark McGranaghan Daniel Brooks Electrotek Concepts, Inc. Phone 423-470-9222, Fax 423-470-9223, email markm@electrotek.com 408 North Cedar Bluff Road, Suite 500 Knoxville, Tennessee 37923 Abstract Deregulation

More information

2 Grounding of power supply system neutral

2 Grounding of power supply system neutral 2 Grounding of power supply system neutral 2.1 Introduction As we had seen in the previous chapter, grounding of supply system neutral fulfills two important functions. 1. It provides a reference for the

More information

Reducing the Effects of Short Circuit Faults on Sensitive Loads in Distribution Systems

Reducing the Effects of Short Circuit Faults on Sensitive Loads in Distribution Systems Reducing the Effects of Short Circuit Faults on Sensitive Loads in Distribution Systems Alexander Apostolov AREVA T&D Automation I. INTRODUCTION The electric utilities industry is going through significant

More information

Harmonic control devices. ECE 528 Understanding Power Quality

Harmonic control devices. ECE 528 Understanding Power Quality ECE 528 Understanding Power Quality http://www.ece.uidaho.edu/ee/power/ece528/ Paul Ortmann portmann@uidaho.edu 208-733-7972 (voice) Lecture 12 1 Today Harmonic control devices In-line reactors (chokes)

More information

p. 1 p. 6 p. 22 p. 46 p. 58

p. 1 p. 6 p. 22 p. 46 p. 58 Comparing power factor and displacement power factor corrections based on IEEE Std. 18-2002 Harmonic problems produced from the use of adjustable speed drives in industrial plants : case study Theory for

More information

ECE 528 Understanding Power Quality

ECE 528 Understanding Power Quality ECE 528 Understanding Power Quality http://www.ece.uidaho.edu/ee/power/ece528/ Paul Ortmann portmann@uidaho.edu 208-733-7972 (voice) Lecture 22 1 Today Homework 5 questions Homework 6 discussion More on

More information

DP&L s Technical Requirements for Interconnection and Parallel Operation of Distributed Generation

DP&L s Technical Requirements for Interconnection and Parallel Operation of Distributed Generation DP&L s Technical Requirements for Interconnection and Parallel Operation of Distributed Generation Technical Requirements for Interconnection and Parallel Operation of Distributed Generation Single Phase

More information

PRACTICAL PROBLEMS WITH SUBSTATION EARTHING

PRACTICAL PROBLEMS WITH SUBSTATION EARTHING 1 PRACTICAL PROBLEMS WITH SUBSTATION EARTHING Dr Hendri Geldenhuys Craig Clark Eskom Distribution Technology This paper considers the issues around substation sites where the soil resistivity is of particularly

More information

Fundamentals of Power Quality

Fundamentals of Power Quality NWEMS Fundamentals of Power Quality August 20 24, 2018 Seattle, WA Track D Anaisha Jaykumar (SEL) Class Content» Introduction to power quality (PQ)» Causes of poor PQ and impact of application» PQ characteristics»

More information

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements Division 502 Technical Applicability 1(1) Section 502.1 applies to: Expedited Filing Draft August 22, 2017 the legal owner of an aggregated generating facility directly connected to the transmission system

More information

Product Classroom. Introduction. Grounding Systems. TN system. Title. Grounding System Introduction. Date October, 2016.

Product Classroom. Introduction. Grounding Systems. TN system. Title. Grounding System Introduction. Date October, 2016. Title Grounding System Introduction Date October, 2016 Related Products Key words All industrial automation products Grounding, Earthing, TN, TT, IT, Introduction The automation industry of today has adopted

More information

CHAPTER 4 POWER QUALITY AND VAR COMPENSATION IN DISTRIBUTION SYSTEMS

CHAPTER 4 POWER QUALITY AND VAR COMPENSATION IN DISTRIBUTION SYSTEMS 84 CHAPTER 4 POWER QUALITY AND VAR COMPENSATION IN DISTRIBUTION SYSTEMS 4.1 INTRODUCTION Now a days, the growth of digital economy implies a widespread use of electronic equipment not only in the industrial

More information

Summary of the Impacts of Grounding on System Protection

Summary of the Impacts of Grounding on System Protection Summary of the Impacts of Grounding on System Protection Grounding System grounding big impact on ability to detect ground faults Common ground options:» Isolated ground (ungrounded)» High impedance ground»

More information

Table of Contents. Introduction... 1

Table of Contents. Introduction... 1 Table of Contents Introduction... 1 1 Connection Impact Assessment Initial Review... 2 1.1 Facility Design Overview... 2 1.1.1 Single Line Diagram ( SLD )... 2 1.1.2 Point of Disconnection - Safety...

More information

Artificial Neural Networks approach to the voltage sag classification

Artificial Neural Networks approach to the voltage sag classification Artificial Neural Networks approach to the voltage sag classification F. Ortiz, A. Ortiz, M. Mañana, C. J. Renedo, F. Delgado, L. I. Eguíluz Department of Electrical and Energy Engineering E.T.S.I.I.,

More information

QUESTION BANK PART - A

QUESTION BANK PART - A QUESTION BANK SUBJECT: EE6005-Power Quality SEM / YEAR: VII SEMESTER / ACADEMIC YEAR 08-09 UNIT I - INTRODUCTION TO POWER QUALITY Terms and definitions: Overloading - under voltage - over voltage. Concepts

More information

POWER CORPORATION. Power Quality. Specifications and Guidelines for Customers. Phone: Fax:

POWER CORPORATION. Power Quality. Specifications and Guidelines for Customers. Phone: Fax: POWER CORPORATION Power Quality Specifications and Guidelines for Customers Phone: 403-514-3700 Fax: 403-514-3719 1 GENERAL OVERVIEW........................................ 1.1 WHAT DOES THIS SPECIFICATION

More information

POWER QUALITY AND SAFETY

POWER QUALITY AND SAFETY POWER QUALITY AND SAFETY Date : November 27, 2015 Venue : 40 th IIEE Annual National Convention and 3E XPO 2015 PRESENTATION OUTLINE Power Quality I. INTRODUCTION II. GRID CODE REQUIREMENTS III. ERC RESOLUTION

More information

SAFETY ASPECTS AND NOVEL TECHNICAL SOLUTIONS FOR EARTH FAULT MANAGEMENT IN MV ELECTRICITY DISTRIBUTION NETWORKS

SAFETY ASPECTS AND NOVEL TECHNICAL SOLUTIONS FOR EARTH FAULT MANAGEMENT IN MV ELECTRICITY DISTRIBUTION NETWORKS SAFETY ASPECTS AND NOVEL TECHNICAL SOLUTIONS FOR EARTH FAULT MANAGEMENT IN MV ELECTRICITY DISTRIBUTION NETWORKS A. Nikander*, P. Järventausta* *Tampere University of Technology, Finland, ari.nikander@tut.fi,

More information

Roadmap For Power Quality Standards Development

Roadmap For Power Quality Standards Development Roadmap For Power Quality Standards Development IEEE Power Quality Standards Coordinating Committee Authors: David B. Vannoy, P.E., Chair Mark F. McGranghan, Vice Chair S. Mark Halpin, Vice Chair D. Daniel

More information

Wind Power Facility Technical Requirements CHANGE HISTORY

Wind Power Facility Technical Requirements CHANGE HISTORY CHANGE HISTORY DATE VERSION DETAIL CHANGED BY November 15, 2004 Page 2 of 24 TABLE OF CONTENTS LIST OF TABLES...5 LIST OF FIGURES...5 1.0 INTRODUCTION...6 1.1 Purpose of the Wind Power Facility Technical

More information

Estimation of Fault Resistance from Fault Recording Data. Daniel Wong & Michael Tong 2014-November-5

Estimation of Fault Resistance from Fault Recording Data. Daniel Wong & Michael Tong 2014-November-5 Estimation of Fault Resistance from Fault Recording Data Daniel Wong & Michael Tong 2014-November-5 Agenda Project Background & Introduction Fault Resistance & Effect Estimation Algorithm Estimation Results

More information

Grounding for Power Quality

Grounding for Power Quality Presents Grounding for Power Quality Grounding for Power Quality NEC 250.53 states that ground resistance should be less than 25 ohms. Is this true? Grounding for Power Quality No! NEC 250.53 states

More information

Protection Basics Presented by John S. Levine, P.E. Levine Lectronics and Lectric, Inc GE Consumer & Industrial Multilin

Protection Basics Presented by John S. Levine, P.E. Levine Lectronics and Lectric, Inc GE Consumer & Industrial Multilin Protection Basics Presented by John S. Levine, P.E. Levine Lectronics and Lectric, Inc. 770 565-1556 John@L-3.com 1 Protection Fundamentals By John Levine 2 Introductions Tools Outline Enervista Launchpad

More information

OVERVIEW OF IEEE STD GUIDE FOR VOLTAGE SAG INDICES

OVERVIEW OF IEEE STD GUIDE FOR VOLTAGE SAG INDICES OVERVIEW OF IEEE STD 1564-2014 GUIDE FOR VOLTAGE SAG INDICES ABSTRACT Daniel SABIN Electrotek Concepts USA d.sabin@ieee.org IEEE Std 1564-2014 Guide for Voltage Sag Indices is a new standard that identifies

More information

Earthing of Electrical Devices and Safety

Earthing of Electrical Devices and Safety Earthing of Electrical Devices and Safety JOŽE PIHLER Faculty of Electrical Engineering and Computer Sciences University of Maribor Smetanova 17, 2000 Maribor SLOVENIA joze.pihler@um.si Abstract: - This

More information

POWER QUALITY IMPROVEMENT BY USING ACTIVE POWER FILTERS

POWER QUALITY IMPROVEMENT BY USING ACTIVE POWER FILTERS POWER QUALITY IMPROVEMENT BY USING ACTIVE POWER FILTERS Ramesh Kumar V 1, Dr. Dalvinder Kaur Mangal 2 1 Research Scholar, Department of Electrical Engineering, Sunrise University, Alwar 2 Asso. Prof.,

More information

Experiences on using gapless waveform data & synchronized harmonic phasors

Experiences on using gapless waveform data & synchronized harmonic phasors 1 Panel Session: New Techniques for Power Quality Measurement and Field Experiences 15PESGM3040 Experiences on using gapless waveform data & synchronized harmonic phasors Wilsun Xu University of Alberta

More information

CHAPTER ELECTROMAGNETIC COMPATIBILITY. Contents of this Chapter...

CHAPTER ELECTROMAGNETIC COMPATIBILITY. Contents of this Chapter... CHAPTER ELECTROMAGNETIC 4 COMPATIBILITY Contents of this Chapter... 4.0 Electromagnetic Compatibility (EMC)............4 2 4.1 Introduction................................4 2 4.2 Applicable Standard Within

More information

Sequence Networks p. 26 Sequence Network Connections and Voltages p. 27 Network Connections for Fault and General Unbalances p. 28 Sequence Network

Sequence Networks p. 26 Sequence Network Connections and Voltages p. 27 Network Connections for Fault and General Unbalances p. 28 Sequence Network Preface p. iii Introduction and General Philosophies p. 1 Introduction p. 1 Classification of Relays p. 1 Analog/Digital/Numerical p. 2 Protective Relaying Systems and Their Design p. 2 Design Criteria

More information

[Nayak, 3(2): February, 2014] ISSN: Impact Factor: 1.852

[Nayak, 3(2): February, 2014] ISSN: Impact Factor: 1.852 IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY Classification of Transmission Line Faults Using Wavelet Transformer B. Lakshmana Nayak M.TECH(APS), AMIE, Associate Professor,

More information

Anti-IslandingStrategyforaPVPowerPlant

Anti-IslandingStrategyforaPVPowerPlant Global Journal of Researches in Engineering: F Electrical and Electronics Engineering Volume 15 Issue 7 Version 1.0 Type: Double Blind Peer Reviewed International Research Journal Publisher: Global Journals

More information

Fatima Michael college of Engineering and Technology

Fatima Michael college of Engineering and Technology Fatima Michael college of Engineering and Technology DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE2303 TRANSMISSION AND DISTRIBUTION SEM: V Question bank UNIT I INTRODUCTION 1. What is the electric

More information

Hamdy Faramawy Senior Application Specialist ABB Sweden

Hamdy Faramawy Senior Application Specialist ABB Sweden Design, Engineering and Application of New Firm Capacity Control System (FCCS) Mohammed Y. Tageldin, MSc. MIET Senior Protection Systems Engineer ABB United Kingdom mohammed.tageldin@gb.abb.com Hamdy Faramawy

More information

NEW METHOD FOR HIGH-IMPEDANCE FAULT DETECTION

NEW METHOD FOR HIGH-IMPEDANCE FAULT DETECTION NEW METHOD FOR HIGH-IMPEDANCE FAULT DETECTION ABSTRACT Hannu LAAKSONEN ABB Oy Finland hannu.laaksonen@fi.abb.com Correct detection of high-impedance faults (HIFs) is crucial because they produce a serious

More information

This webinar brought to you by The Relion Product Family Next Generation Protection and Control IEDs from ABB

This webinar brought to you by The Relion Product Family Next Generation Protection and Control IEDs from ABB This webinar brought to you by The Relion Product Family Next Generation Protection and Control IEDs from ABB Relion. Thinking beyond the box. Designed to seamlessly consolidate functions, Relion relays

More information

SHORT CIRCUIT ANALYSIS OF 220/132 KV SUBSTATION BY USING ETAP

SHORT CIRCUIT ANALYSIS OF 220/132 KV SUBSTATION BY USING ETAP SHORT CIRCUIT ANALYSIS OF 220/132 KV SUBSTATION BY USING ETAP Kiran V. Natkar 1, Naveen Kumar 2 1 Student, M.E., Electrical Power System, MSS CET/ Dr. B.A.M. University, (India) 2 Electrical Power System,

More information

Section 6: System Grounding Bill Brown, P.E., Square D Engineering Services

Section 6: System Grounding Bill Brown, P.E., Square D Engineering Services Section 6: System Grounding Bill Brown, P.E., Square D Engineering Services Introduction The topic of system grounding is extremely important, as it affects the susceptibility of the system to voltage

More information

Unit V. Power Quality Monitoring

Unit V. Power Quality Monitoring .. Unit V Power Quality Monitoring Monitoring Considerations monitoring and diagnostic techniques for various power quality problems modeling of power quality problems by mathematical simulation tools

More information

Real-time Monitoring of Power Oscillations and Modal Damping in the European ENTSO-E System

Real-time Monitoring of Power Oscillations and Modal Damping in the European ENTSO-E System Mats Larsson, ABB CRC Switzerland; Luis-Fabiano Santos, ABB SAS Switzerland; Galina Antonova, AB B SA Canada, Reynaldo Nuqui, ABB CRC USA NASPI meeting, February 20, 2013 Real-time Monitoring of Power

More information

SAFETY ISSUES RELATED TO THE CONNECTION OF MV AND HV GROUNDING

SAFETY ISSUES RELATED TO THE CONNECTION OF MV AND HV GROUNDING SAFETY ISSUES RELATED TO THE CONNECTION OF MV AND HV GROUNDING Y. Rajotte J. Fortin G. Lessard Hydro-Québec, Canada Hydro-Québec, Canada Hydro-Québec, Canada e-mails: rajotte.yves@ireq.ca fortin.jacques@ireq.ca

More information

Renewable Interconnection Standard & Experimental Tests. Yahia Baghzouz UNLV Las Vegas, NV, USA

Renewable Interconnection Standard & Experimental Tests. Yahia Baghzouz UNLV Las Vegas, NV, USA Renewable Interconnection Standard & Experimental Tests Yahia Baghzouz UNLV Las Vegas, NV, USA Overview IEEE Std 1547 Voltage limitations Frequency limitations Harmonic limitations Expansion of IEEE Std

More information

Fault Location Using Sparse Wide Area Measurements

Fault Location Using Sparse Wide Area Measurements 319 Study Committee B5 Colloquium October 19-24, 2009 Jeju Island, Korea Fault Location Using Sparse Wide Area Measurements KEZUNOVIC, M., DUTTA, P. (Texas A & M University, USA) Summary Transmission line

More information

Benchmarking Distribution Power Quality at BGE

Benchmarking Distribution Power Quality at BGE Benchmarking Distribution Power Quality at BGE Dewane Daley Engineer Baltimore Gas & Electric Company 410-291-3198 dewane.a.daley@bge.com Large Scale Benchmarking Projects at BGE Distribution System Power

More information

Industrial and Commercial Power Systems Topic 7 EARTHING

Industrial and Commercial Power Systems Topic 7 EARTHING The University of New South Wales School of Electrical Engineering and Telecommunications Industrial and Commercial Power Systems Topic 7 EARTHING 1 INTRODUCTION Advantages of earthing (grounding): Limitation

More information

Modern transformer relays include a comprehensive set of protective elements to protect transformers from faults and abnormal operating conditions

Modern transformer relays include a comprehensive set of protective elements to protect transformers from faults and abnormal operating conditions 1 Transmission transformers are important links in the bulk power system. They allow transfer of power from generation centers, up to the high-voltage grid, and to bulk electric substations for distribution

More information

E S C R I P T I V E B U L L E T I N .,.,.,. Bulletin DB-106. October, Square D Company Power System Studies ---1 I SQU ARED COMPANY --

E S C R I P T I V E B U L L E T I N .,.,.,. Bulletin DB-106. October, Square D Company Power System Studies ---1 I SQU ARED COMPANY -- D.,.,.,. E S C R I P T I V E B U L L E T I N Bulletin DB-106 Square D Company October, 1990 ---1 I SQU ARED COMPANY -- Electrical Power Distribution System - The Heart of the Business From small commercial

More information

EMC Philosophy applied to Design the Grounding Systems for Gas Insulation Switchgear (GIS) Indoor Substation

EMC Philosophy applied to Design the Grounding Systems for Gas Insulation Switchgear (GIS) Indoor Substation EMC Philosophy applied to Design the Grounding Systems for Gas Insulation Switchgear (GIS) Indoor Substation Marcos Telló Department of Electrical Engineering Pontifical Catholic University of Rio Grande

More information

MODELING THE EFFECTIVENESS OF POWER ELECTRONICS BASED VOLTAGE REGULATORS ON DISTRIBUTION VOLTAGE DISTURBANCES

MODELING THE EFFECTIVENESS OF POWER ELECTRONICS BASED VOLTAGE REGULATORS ON DISTRIBUTION VOLTAGE DISTURBANCES MODELING THE EFFECTIVENESS OF POWER ELECTRONICS BASED VOLTAGE REGULATORS ON DISTRIBUTION VOLTAGE DISTURBANCES James SIMONELLI Olivia LEITERMANN Jing HUANG Gridco Systems USA Gridco Systems USA Gridco Systems

More information

Mitigation of voltage disturbances (Sag/Swell) utilizing dynamic voltage restorer (DVR)

Mitigation of voltage disturbances (Sag/Swell) utilizing dynamic voltage restorer (DVR) Research Journal of Engineering Sciences ISSN 2278 9472 Mitigation of voltage disturbances (Sag/Swell) utilizing dynamic voltage restorer (DVR) Abstract Srishti Verma * and Anupama Huddar Electrical Engineering

More information

Measurement tools at heart of Smart Grid need calibration to ensure reliability

Measurement tools at heart of Smart Grid need calibration to ensure reliability Measurement tools at heart of Smart Grid need calibration to ensure reliability Smart grid; PMU calibration position 1 The North American interconnections, or electric transmission grids, operate as a

More information

Analysis of Microprocessor Based Protective Relay s (MBPR) Differential Equation Algorithms

Analysis of Microprocessor Based Protective Relay s (MBPR) Differential Equation Algorithms WWWJOURNALOFCOMPUTINGORG 21 Analysis of Microprocessor Based Protective Relay s (MBPR) Differential Equation Algorithms Bruno Osorno Abstract This paper analyses and explains from the systems point of

More information

BED INTERCONNECTION TECHNICAL REQUIREMENTS

BED INTERCONNECTION TECHNICAL REQUIREMENTS BED INTERCONNECTION TECHNICAL REQUIREMENTS By Enis Šehović, P.E. 2/11/2016 Revised 5/19/2016 A. TABLE OF CONTENTS B. Interconnection Processes... 2 1. Vermont Public Service Board (PSB) Rule 5.500... 2

More information

POWER QUALITY IMPROVEMENT BY USING ACTIVE POWER FILTERS

POWER QUALITY IMPROVEMENT BY USING ACTIVE POWER FILTERS POWER QUALITY IMPROVEMENT BY USING ACTIVE POWER FILTERS Saheb Hussain MD 1, K.Satyanarayana 2, B.K.V.Prasad 3 1 Assistant Professor, EEE Department, VIIT, A.P, India, saheb228@vignanvizag.com 2 Ph.D Scholar,

More information

Highgate Converter Overview. Prepared by Joshua Burroughs & Jeff Carrara IEEE PES

Highgate Converter Overview. Prepared by Joshua Burroughs & Jeff Carrara IEEE PES Highgate Converter Overview Prepared by Joshua Burroughs & Jeff Carrara IEEE PES Highgate Converter Abstract Introduction to HVDC Background on Highgate Operation and Control schemes of Highgate 22 Why

More information

DETECTION AND CLASSIFICATION OF POWER QUALITY DISTURBANCES

DETECTION AND CLASSIFICATION OF POWER QUALITY DISTURBANCES DETECTION AND CLASSIFICATION OF POWER QUALITY DISTURBANCES Ph.D. THESIS by UTKARSH SINGH INDIAN INSTITUTE OF TECHNOLOGY ROORKEE ROORKEE-247 667 (INDIA) OCTOBER, 2017 DETECTION AND CLASSIFICATION OF POWER

More information

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013 A Statcom-Control Scheme for Power Quality Improvement of Grid Connected Wind Energy System B.T.RAMAKRISHNARAO*, B.ESWARARAO**, L.NARENDRA**, K.PRAVALLIKA** * Associate.Professor, Dept.of EEE, Lendi Inst.Of

More information

Introduction to Harmonics and Power Quality

Introduction to Harmonics and Power Quality NWEMS Introduction to Harmonics and Power Quality August 20 24, 2018 Seattle, WA Track B Anaisha Jaykumar (SEL) Class Content» Definition of power quality (PQ)» Impact of PQ problems» Sources of poor PQ»

More information

Digital Fault Recorder Deployment at HVDC Converter Stations

Digital Fault Recorder Deployment at HVDC Converter Stations Digital Fault Recorder Deployment at HVDC Converter Stations On line continuous monitoring at HVDC Converter Stations is an important asset in determining overall system performance and an essential diagnostic

More information

Power Quality Basics. Presented by. Scott Peele PE

Power Quality Basics. Presented by. Scott Peele PE Power Quality Basics Presented by Scott Peele PE PQ Basics Terms and Definitions Surge, Sag, Swell, Momentary, etc. Measurements Causes of Events Possible Mitigation PQ Tool Questions Power Quality Measurement

More information

Electrical Power Systems

Electrical Power Systems Electrical Power Systems CONCEPT, THEORY AND PRACTICE SECOND EDITION SUBIR RAY Professor MVJ College of Engineering Bangalore PHI Learning Pfcte tofm Delhi-110092 2014 Preface xv Preface to the First Edition

More information

1. Introduction to Power Quality

1. Introduction to Power Quality 1.1. Define the term Quality A Standard IEEE1100 defines power quality (PQ) as the concept of powering and grounding sensitive electronic equipment in a manner suitable for the equipment. A simpler and

More information

Minnesota Power Systems Conference 2015 Improving System Protection Reliability and Security

Minnesota Power Systems Conference 2015 Improving System Protection Reliability and Security Minnesota Power Systems Conference 2015 Improving System Protection Reliability and Security Steve Turner Senior Application Engineer Beckwith Electric Company Introduction Summarize conclusions from NERC

More information

No. SSIEC-SEW SHINSUNG. Solid Insulation Eco Load Break Switch (SILO) SILO SERIES 15kV, 27kV 400A, 630A

No. SSIEC-SEW SHINSUNG. Solid Insulation Eco Load Break Switch (SILO) SILO SERIES 15kV, 27kV 400A, 630A SHINSUNG Solid Insulation Eco Load Break Switch (SILO) SILO SERIES 15kV, 27kV 400A, 630A Enhanced Self Healing System General SILO is 3 phase, solid insulated load break switch (LBS) and vacuum interruption

More information

Adaptive Autoreclosure to Increase System Stability and Reduce Stress to Circuit Breakers

Adaptive Autoreclosure to Increase System Stability and Reduce Stress to Circuit Breakers Adaptive Autoreclosure to Increase System Stability and Reduce Stress to Circuit Breakers 70 th Annual Conference for Protective Relay Engineers Siemens AG 2017 All rights reserved. siemens.com/energy-management

More information

ENSURING PUBLIC SAFETY THROUGH PROPER EARTHING IN LOW VOLTAGE NETWORKS

ENSURING PUBLIC SAFETY THROUGH PROPER EARTHING IN LOW VOLTAGE NETWORKS ENSURING PUBLIC SAFETY THROUGH PROPER EARTHING IN LOW VOLTAGE NETWORKS Sharmistha BHATTACHARYYA Enexis The Netherlands sharmirb@yahoo.com ABSTRACT Every electrical supply network should provide a proper

More information

THE IMPACT OF NETWORK SPLITTING ON FAULT LEVELS AND OTHER PERFORMANCE MEASURES

THE IMPACT OF NETWORK SPLITTING ON FAULT LEVELS AND OTHER PERFORMANCE MEASURES THE IMPACT OF NETWORK SPLITTING ON FAULT LEVELS AND OTHER PERFORMANCE MEASURES C.E.T. Foote*, G.W. Ault*, J.R. McDonald*, A.J. Beddoes *University of Strathclyde, UK EA Technology Limited, UK c.foote@eee.strath.ac.uk

More information

Protection Scheme for Energy Storage Systems Operating in Island or Grid Connected Modes

Protection Scheme for Energy Storage Systems Operating in Island or Grid Connected Modes 24 th International Conference on Electricity Distribution Glasgow, 12-15 June 217 Paper 182 Protection Scheme for Energy Storage Systems Operating in Island or Grid Connected Modes Andre NEVES Bernardo

More information

Review on Shunt Active Power Filter for Three Phase Four Wire System

Review on Shunt Active Power Filter for Three Phase Four Wire System 2014 IJEDR Volume 2, Issue 1 ISSN: 2321-9939 Review on Shunt Active Power Filter for Three Phase Four Wire System 1 J. M. Dadawala, 2 S. N. Shivani, 3 P. L. Kamani 1 Post-Graduate Student (M.E. Power System),

More information

Power Conditioning Equipment for Improvement of Power Quality in Distribution Systems M. Weinhold R. Zurowski T. Mangold L. Voss

Power Conditioning Equipment for Improvement of Power Quality in Distribution Systems M. Weinhold R. Zurowski T. Mangold L. Voss Power Conditioning Equipment for Improvement of Power Quality in Distribution Systems M. Weinhold R. Zurowski T. Mangold L. Voss Siemens AG, EV NP3 P.O. Box 3220 91050 Erlangen, Germany e-mail: Michael.Weinhold@erls04.siemens.de

More information

1 Comparison of Approaches (SESTLC, ROW & HIFREQ) for AC Interference Study

1 Comparison of Approaches (SESTLC, ROW & HIFREQ) for AC Interference Study 1 Comparison of Approaches (SESTLC, ROW & HIFREQ) for AC Interference Study 1 Comparison of Approaches (SESTLC, ROW & HIFREQ) for AC Interference Study 1.1 Introduction Yexu Li and Simon Fortin Three independent

More information

DRAFT. City of Lethbridge Electric ENGINEERING STANDARDS GUIDELINE FOR GENERATOR INTERCONNECTION THE CITY OF LETHBRIDGE ELECTRIC DISTRIBUTION SYSTEM

DRAFT. City of Lethbridge Electric ENGINEERING STANDARDS GUIDELINE FOR GENERATOR INTERCONNECTION THE CITY OF LETHBRIDGE ELECTRIC DISTRIBUTION SYSTEM City of Lethbridge Electric ENGINEERING STANDARDS DRAFT GUIDELINE FOR GENERATOR INTERCONNECTION TO THE CITY OF LETHBRIDGE ELECTRIC DISTRIBUTION SYSTEM Rev. 1 Rev. Date: 2003/01/24 Prepared by: Brent Smith

More information

A Novel Control Method for Input Output Harmonic Elimination of the PWM Boost Type Rectifier Under Unbalanced Operating Conditions

A Novel Control Method for Input Output Harmonic Elimination of the PWM Boost Type Rectifier Under Unbalanced Operating Conditions IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 16, NO. 5, SEPTEMBER 2001 603 A Novel Control Method for Input Output Harmonic Elimination of the PWM Boost Type Rectifier Under Unbalanced Operating Conditions

More information

Technical Interconnection Requirements For Transmission Voltage Customers for Service at 60,000 to 287,000 Volts R XX

Technical Interconnection Requirements For Transmission Voltage Customers for Service at 60,000 to 287,000 Volts R XX Technical Interconnection Requirements For Transmission Voltage Customers for Service at 60,000 to 287,000 Volts R XX May 2018 Disclaimer This document provides general technical interconnection requirements

More information

Introduce system protection relays like underfrequency relays, rate of change of frequency relays, reverse - power flow

Introduce system protection relays like underfrequency relays, rate of change of frequency relays, reverse - power flow Module 1 : Fundamentals of Power System Protection Lecture 3 : Protection Paradigms - System Protection Objectives In this lecture we will: Overview dynamics in power systems. Introduce system protection

More information

Generation Interconnection Requirements at Voltages 34.5 kv and Below

Generation Interconnection Requirements at Voltages 34.5 kv and Below Generation Interconnection Requirements at Voltages 34.5 kv and Below 2005 March GENERATION INTERCONNECTION REQUIREMENTS AT 34.5 KV AND BELOW PAGE 1 OF 36 TABLE OF CONTENTS 1. INTRODUCTION 5 1.1. Intent

More information

New solution for feeder earth-fault protection

New solution for feeder earth-fault protection Application Note New solution to feeder earth-fault protection 1 (8) APPLICATION NOTE New solution for feeder earth-fault protection AQ-200 IED series Application Note New solution to feeder earth-fault

More information

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING. Rev. 01

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING. Rev. 01 SEC DISTRIBUTION GROUNDING STANDARD SDCS-03 Part-II Rev.01 SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING Rev. 01 This specification is property of SEC

More information

PSV3St _ Phase-Sequence Voltage Protection Stage1 (PSV3St1) Stage2 (PSV3St2)

PSV3St _ Phase-Sequence Voltage Protection Stage1 (PSV3St1) Stage2 (PSV3St2) 1MRS752324-MUM Issued: 3/2000 Version: D/23.06.2005 Data subject to change without notice PSV3St _ Phase-Sequence Voltage Protection Stage1 (PSV3St1) Stage2 (PSV3St2) Contents 1. Introduction... 2 1.1

More information

Module 9. Fault Type Form 4.X RELIABILITY ACCOUNTABILITY

Module 9. Fault Type Form 4.X RELIABILITY ACCOUNTABILITY Module 9 Fault Type Form 4.X 1 M9 Fault Type The descriptor of the fault, if any, associated with each Automatic Outage of an Element. 1. No fault 2. Phase-to-phase fault (P-P) 3. Single phase-to-ground

More information

CHAPTER 1 INTRODUCTION

CHAPTER 1 INTRODUCTION 1 CHAPTER 1 INTRODUCTION 1.1 BACKGROUND The increased use of non-linear loads and the occurrence of fault on the power system have resulted in deterioration in the quality of power supplied to the customers.

More information

Compensation of Distribution Feeder Loading With Power Factor Correction by Using D-STATCOM

Compensation of Distribution Feeder Loading With Power Factor Correction by Using D-STATCOM Compensation of Distribution Feeder Loading With Power Factor Correction by Using D-STATCOM N.Shakeela Begum M.Tech Student P.V.K.K Institute of Technology. Abstract This paper presents a modified instantaneous

More information

Monitoring Locations in Smart Grids 14PESGM2391

Monitoring Locations in Smart Grids 14PESGM2391 1 Panel Session PQ Monitoring in the Era of Smart Grids Monitoring Locations in Smart Grids 14PESGM2391 Francisc Zavoda IREQ (HQ) QUÉBEC, CANADA Power System and Monitoring Locations 2 Power System Classic

More information

EH2741 Communication and Control in Electric Power Systems Lecture 2

EH2741 Communication and Control in Electric Power Systems Lecture 2 KTH ROYAL INSTITUTE OF TECHNOLOGY EH2741 Communication and Control in Electric Power Systems Lecture 2 Lars Nordström larsno@kth.se Course map Outline Transmission Grids vs Distribution grids Primary Equipment

More information

Manjeet Baniwal 1, U.Venkata Reddy 2, Gaurav Kumar Jha 3

Manjeet Baniwal 1, U.Venkata Reddy 2, Gaurav Kumar Jha 3 Application of to alleviate voltage sag and swell Manjeet Baniwal 1, U.Venkata Reddy 2, Gaurav Kumar Jha 3 123 (Electrical Engineering, AGPCE Nagpur/ RTMNU, INDIA) ABSTRACT : This paper deals with modelling

More information

Power Quality - 1. Introduction to Power Quality. Content. Course. Ljubljana, Slovenia 2013/14. Prof. dr. Igor Papič

Power Quality - 1. Introduction to Power Quality. Content. Course. Ljubljana, Slovenia 2013/14. Prof. dr. Igor Papič Course Power Quality - 1 Ljubljana, Slovenia 2013/14 Prof. dr. Igor Papič igor.papic@fe.uni-lj.si Introduction to Power Quality Content Session 1 Session 2 Session 3 Session 4 1st day 2nd day 3rd day 4th

More information

PRC Generator Relay Loadability. A. Introduction 1. Title: Generator Relay Loadability 2. Number: PRC-025-1

PRC Generator Relay Loadability. A. Introduction 1. Title: Generator Relay Loadability 2. Number: PRC-025-1 PRC-025-1 Generator Relay Loadability A. Introduction 1. Title: Generator Relay Loadability 2. Number: PRC-025-1 Purpose: To set load-responsive protective relays associated with generation Facilities

More information

Fault Localization using Wavelet Transforms in 132kV Transmission Lines

Fault Localization using Wavelet Transforms in 132kV Transmission Lines ENGINEER - Vo). XXXXII, No. 04, pp. [95-104], 2009 The Institution of Engineers, Sri Lanka Fault Localization using Wavelet Transforms in 132kV Transmission Lines J.V.U.P. Jayatunga, P.S.N. De Silva and

More information

Power System Protection Where Are We Today?

Power System Protection Where Are We Today? 1 Power System Protection Where Are We Today? Meliha B. Selak Power System Protection & Control IEEE PES Distinguished Lecturer Program Preceding IEEE PES Vice President for Chapters melihas@ieee.org PES

More information

POWER QUALITY SPECIFICATIONS AND GUIDELINES FOR CUSTOMERS ENGINEERING STANDARDS CITY OF LETHBRIDGE ELECTRIC

POWER QUALITY SPECIFICATIONS AND GUIDELINES FOR CUSTOMERS ENGINEERING STANDARDS CITY OF LETHBRIDGE ELECTRIC CITY OF LETHBRIDGE ELECTRIC ENGINEERING STANDARDS POWER QUALITY SPECIFICATIONS AND GUIDELINES FOR CUSTOMERS The City of Lethbridge acknowledges the use of other utility industry and industry committee

More information

Unit Auxiliary Transformer (UAT) Relay Loadability Report

Unit Auxiliary Transformer (UAT) Relay Loadability Report Background and Objective Reliability Standard, PRC 025 1 Generator Relay Loadability (standard), developed under NERC Project 2010 13.2 Phase 2 of Relay Loadability: Generation, was adopted by the NERC

More information

Design and Simulation of Passive Filter

Design and Simulation of Passive Filter Chapter 3 Design and Simulation of Passive Filter 3.1 Introduction Passive LC filters are conventionally used to suppress the harmonic distortion in power system. In general they consist of various shunt

More information

Generation and Load Interconnection Standard

Generation and Load Interconnection Standard Generation and Load Interconnection Standard Rev. 0A DRAFT Name Signature Date Prepared: Approved: VP Acceptance APEGGA Permit to Practice P-08200 TABLE OF CONTENTS 1.0 INTRODUCTION...5 1.1 Purpose...5

More information

Impacts of the Renewable Energy Resources on the Power System Protection by: Brent M. Fedele, P.E., National Grid for: 11 th Annual CNY Engineering

Impacts of the Renewable Energy Resources on the Power System Protection by: Brent M. Fedele, P.E., National Grid for: 11 th Annual CNY Engineering Impacts of the Renewable Energy Resources on the Power System Protection by: Brent M. Fedele, P.E., National Grid for: 11 th Annual CNY Engineering Expo - Nov. 3, 2014 Index Normal Distribution System

More information

ACCURATE SIMULATION OF AC INTERFERENCE CAUSED BY ELECTRICAL POWER LINES: A PARAMETRIC ANALYSIS

ACCURATE SIMULATION OF AC INTERFERENCE CAUSED BY ELECTRICAL POWER LINES: A PARAMETRIC ANALYSIS ACCURATE SIMULATION OF AC INTERFERENCE CAUSED BY ELECTRICAL POWER LINES: A PARAMETRIC ANALYSIS J. Liu and F. P. Dawalibi Safe Engineering Services & technologies ltd. 1544 Viel, Montreal, Quebec, Canada

More information

OPERATING, METERING AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 25,000 KILOWATTS

OPERATING, METERING AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 25,000 KILOWATTS OPERATING, METERING AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 25,000 KILOWATTS AND MEDIUM-SIZE FACILITIES (5,000-25,000KW) CONNECTED

More information