1 FLEX I/O and FLEX Integra Technical Data 1794 Series and 1793 Series Flexible, Inexpensive, and Compact Additional Savings for Larger Systems Compatibility Now and In the Future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
2 2 Overview FLEX I/O and FLEX Integra Product Data Low Installation, Wiring, and Maintenance Costs ControlNet Network ControlNet network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processor, PLC-5/40C processor, or PLC-5/80C processor 1794 FLEX I/O with 1793 FLEX Integra Remote I/O Network local computer with 1784-KTCX15 card Remote I/O remote rack PLC-5/40 laptop computer 1784-PCC PanelView operator interface 1771-ACN(R) SLC 5/03 processor with 1747-SN scanner module 1791-IOX 128-point block 1336 drive 1794 FLEX I/O with 1793 FLEX Integra 1794 FLEX I/O AC 32-point block 1747-AS 1400-PD power monitor display module 1794 FLEX I/O with 1793 FLEX Integra DeviceNet Network 1771-SDN scanner 1747-SDN scanner 1747-AS PanelView operator interface GK5 interface module DeviceNet network 1794 FLEX I/O with 1793 FLEX Integra 1784-PCD module host computer with DeviceNetManager software Compactlock I/O Armorlock MaXum I/O 1336 FORCE drive 1336 PLUS drive 1305 drive 41478
3 FLEX I/O and FLEX Integra Product Data Overview 3 2YHUYLHZ For information on See page 1794 FLEX I/O 3 About the FLEX I/O System 1793 FLEX Integra 4 )/(;,2FRQVLVWVRIWKUHHVSDFHVDYLQJFRPSRQHQWV DGDSWHUV WHUPLQDOEDVHXQLWV,2PRGXOHV Adapter Flexbus Connectors Terminal ase Keyswitch Flexbus Connector I/O Module 1794-I16 Remote I/O Connector Use the adapter to power the internal logic for as many as eight I/O modules and transfer the I/O data back to a PLC processor or a SLC processor via one of several available networks. Two separate connection terminals for field power let you daisy-chain power connections to adjacent terminal bases. Terminal Strips field power connection terminals (externally provided) Insert the terminal base into your system using the positive-locking flexbus connectors. Use a three-wire terminal base to wire directly to a two- or three-wire device. Terminate most of your wiring on the terminal base with almost no need for terminal blocks. Use the terminals to daisy-chain power connections to adjacent terminal bases, or connect individual power supplies to each base to isolate modules. Adjust the keyswitch to prevent incorrect module insertion into a preconfigured terminal base. Exchange terminal bases without moving other bases in your system Plug the I/O module into the terminal base. Use the module to connect to the I/O bus and field devices. Remove and insert a module without disturbing the field wiring, other I/O modules, or system power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
4 4 Overview FLEX I/O and FLEX Integra Product Data About the FLEX Integra System )/(;,QWHJUD,2FRQVLVWVRIDUDQJHRIGLJLWDODQGDQDORJPRGXOHVDOO FDSDEOHRIXVHZLWK)/(;,2DGDSWHUVDQGRWKHU)/(;,2 PRGXOHV(DFKPRGXOHLVDYDLODEOHZLWKHLWKHUVFUHZFDJHRU VSULQJFODPSZLUHWHUPLQDWLRQV TIP )/(;,QWHJUDPRGXOHVZHUHGHVLJQHGWRILWWRWKHULJKWRI \RXU)/(;,2PRGXOHV%HVXUHWRSODFH\RXU)/(;,QWHJUDPRGXOHVWRWKHULJKWRI\RXU)/(;,2PRGXOHV ZKHQGHVLJQLQJ\RXUV\VWHP Adapter Integra Modules Flexbus Connector Remote I/O Connector field power connection terminals (externally provided) Field wiring terminals Use the adapter to power the internal logic for as many as eight I/O modules and transfer the I/O data back to a PLC processor or a SLC processor via one of several available networks. Two separate connection terminals for field power let you daisy-chain power connections to adjacent FLEX I/O terminal bases. Insert the module into your system using the positive-locking flexbus connectors. Terminate all of your wiring on the module with no need for terminal blocks. Use the terminals to daisy-chain power connections to adjacent FLEX I/O terminal bases, or connect individual power supplies to each base to isolate modules. ATTENTION! 'RQRWUHPRYHDQ,QWHJUDPRGXOHXQGHUSRZHU 5HPRYLQJWKHPRGXOHXQGHUSRZHUZLOOEUHDNWKH HOHFWULFDOEDFNSODQHIOH[EXVFRQQHFWLRQV7KLVFDQ FDXVHSHUVRQDOLQMXU\RUSURSHUW\GDPDJHE\ VHQGLQJDQHUURQHRXVVLJQDOWR\RXUV\VWHP VILHOG GHYLFHVFDXVLQJXQLQWHQGHGPDFKLQHPRWLRQ FDXVLQJDQH[SORVLRQLQDKD]DUGRXVHQYLURQPHQW EUHDNLQJFRPPXQLFDWLRQVEH\RQGWKLVPRGXOH
5 FLEX I/O and FLEX Integra Product Data Overview 5 Mount and Remove Your System Easily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onnection Point DIN Rail A- part no. 199-DR1 DIN EN (35 x 7.5mm) Hook Screw holes for optional panel-mounting. Locking Lever DIN Rail Side View FLEX I/O adapters, terminal bases, and FLEX Integra modules are slotted to allow DIN-rail mounting. Remote I/O Connector A- part no Locking tab connector holds terminal base onto DIN rail :KHQ\RXXVH)/(;,2PRGXOHVLQDKLJKYLEUDWLRQLQVWDOODWLRQDQG SDUWLFXODUO\ZKHQPRXQWLQJWKHPRGXOHVYHUWLFDOO\ZHUHFRPPHQGXVLQJ ',1UDLOORFNV$OOHQ%UDGOH\SDUWQR($ ATTENTION! 7KHKRRNRQWKHWHUPLQDOEDVHDQGDGMDFHQWFRQQHFWLRQ SRLQWRQWKHDGDSWHUNHHSWKHWHUPLQDOEDVHVWLJKW WRJHWKHUVHHH[SORGHGYLHZDERYH7KHVHFRPSRQHQWVDUH FDSDEOHRIPDLQWDLQLQJDUHOLDEOHFRQQHFWLRQLQFDVHRI VKRFNDQGRUYLEUDWLRQ5HIHUWRWKHHQYLURQPHQWDO FRQGLWLRQVLQIRUPDWLRQLQHDFKPRGXOH VVSHFLILFDWLRQV
6 6 Overview FLEX I/O and FLEX Integra Product Data )/(;,QWHJUDPRGXOHVPRXQWRQWKH',1UDLO$IWHUWKHPRGXOHORFNV LQWRSODFHILUPO\SXVKWKH,QWHJUDPRGXOHLQWRWKHDGMDFHQWPRGXOHWR FRPSOHWHWKHEDFNSODQHFRQQHFWLRQ:KHQUHPRYLQJDQ,QWHJUD PRGXOHLQVHUWDIODWEODGHGVFUHZGULYHUEHWZHHQWKHPRGXOHVDQG WZLVWWXUQ7KHQUHOHDVHWKHORFNLQJOHYHUDQGUHPRYHWKHPRGXOH FLEX Integra Connection point Hook DIN rail A- pt. no. 199-DR1 (35 x 7.5mm) Locking lever DIN rail A A To remove: ATTENTION! 7KHKRRNRQWKHWHUPLQDOEDVHDQGDGMDFHQW FRQQHFWLRQSRLQWRQWKHDGDSWHUNHHSWKHWHUPLQDO EDVHVWLJKWWRJHWKHUVHHH[SORGHGYLHZDERYH 7KHVHFRPSRQHQWVDUHFDSDEOHRIPDLQWDLQLQJD UHOLDEOHFRQQHFWLRQLQFDVHRIVKRFNDQGRU YLEUDWLRQ5HIHUWRWKHHQYLURQPHQWDOFRQGLWLRQV LQIRUPDWLRQLQHDFKPRGXOH VVSHFLILFDWLRQV
7 FLEX I/O and FLEX Integra Product Data Overview 7 Design Your Configuration 2YHUYLHZ <RXFDQXVHDVPDQ\DVHLJKW)/(;,2DQGRU)/(;,QWHJUDPRGXOHV SHUDGDSWHU7KLVIOH[LELOLW\DOORZVDZLGHUDQJHRIGLJLWDODQGDQDORJ,2SRLQWVSHUDGDSWHU0L[DQGPDWFKGLJLWDODQGDQDORJ,2WRPHHW \RXUDSSOLFDWLRQQHHGV <RXFDQXVH)/(;,QWHJUDPRGXOHVZLWK)/(;,2PRGXOHV TIP 3ODFH,QWHJUDPRGXOHVWRWKHULJKWRI\RXU)/(;,2 PRGXOHVZKHQGHVLJQLQJ\RXUV\VWHP Any combination of FLEX I/O and/or FLEX Integra digital or analog modules. Adapter Eight terminal bases (maximum) The number of bases that make up an I/O group depends upon the adapter used Module 0 Module 1 Module 2 Module 3 Optional 1794-CE1 or 1794-CE3 Extender Cable Module 7 Module 6 Module 5 Module 4 Only 1 cable per system When using the optional extender cable, module groups are numbered sequentially along the length of the system. What this Product Data Contains 8VHWKHIROORZLQJWDEOHVWRILQGLQIRUPDWLRQLQWKLVWHFKQLFDOGDWD For Information On See Page Terminal ase Compatibility Cross-Reference Chart 17 Choosing the Correct Counter Module for Your Application 134 Related Publications 152 Mounting Dimensions and Spacing Requirements 154 Support, Training, and Repair Services 155
8 8 Overview FLEX I/O and FLEX Integra Product Data For Information On Catalog Number Description See Page Adapters 1794-ADN DeviceNet Adapter ACN15 ControlNet Adapter ACNR15 ControlNet Redundant Media Adapter AS2/C Remote I/O Adapter (to 2 modules) AS/D Remote I/O Adapter (to 8 modules) 15 Terminal ase Units 1794-T2 2-Wire Screw Clamp Terminal ase Unit T3 3-Wire Screw Clamp Terminal ase Unit T3S 3-Wire Spring Clamp Terminal ase Unit T3T Temperature Terminal ase Unit T3TS Spring Clamp Temperature Terminal ase Unit T3G Screw Clamp Grounded Terminal ase Unit T3GS Spring Clamp Grounded Terminal ase Unit TN Terminal ase Unit (NEMA-Style Screws) TNF Fused Terminal ase Unit (NEMA-Style Screws) F1 SCANport TM Terminal ase Unit AC 120V ac Modules 1794-IA8 120V ac 8 Input Module IA8I 120V ac 8 Isolated Input Module IA16 120V ac 16 Input Module OA8 120V ac 8 Output Module OA8I 120V ac 8 Isolated Output Module OA16 120V ac 16 Output Module V ac Modules 1794-IM8 220V ac 8 Input Module OM8 220V ac 8 Output Module DC Modules 1793-I4, -I4S 4 Sink Input Module I16, -I16S 16 Sink Input Module IV16, IV16S 16 Source Input Module O4P, -O4PS 4 Source Output (Protected) Module O16P, -O16PS 16 Protected Source Output Module OV16P, -OV16PS 16 Protected Sink Output Module I2XO2P, -I2XO2PS 2 Input/2 Protected Output Combo Module DC Modules 1794-I8 8 Sink Input Module I16 16 Sink Input Module IV16 16 Source Input Module O8 8 Source Output Module O16 16 Source Output Module O16P 16 Source Output (Protected) Module 75
9 FLEX I/O and FLEX Integra Product Data Overview OV16 16 Sink Output Module DC 1794-OV16P 16 Sink Output (Protected) Module O8EP Electronically Fused 8 Output Module I10XO6 10 Input/6 2A Output Combo Module 83 48V dc Modules 1794-IC16 48V dc 16 Sink Input Module OC16 48V dc 16 Source Output Module Analog Modules 1793-IE4, -IE4S 4 Input Analog Module OE2, -OE2S 2 Output Analog Module IE2XOE1, -IE2XOE1S 2 Input/1 Output Analog Combo Module Analog Modules 1794-IE8/ Selectable Analog 8 Input Module OE4/ Selectable Analog 4 Output Module IE4XOE2/ 4 Input/2 Output Analog Combo Module 103 Isolated Source Modules 1794-IF4I Source Isolated Analog 4 Input Module 108 Analog 1794-OF4I Source Isolated Analog 4 Output Module IF2XOF2I 2 Input/2 Output Isolated Analog Combo Module Relay Relay Module 1793-OW4, -OW4S 4 Relay Sink/Source Output Module Relay Relay Module 1794-OW8 8 Relay Sink/Source Output Module 120 Specialty RTD Input Module 1794-IR8 RTD Input Module 123 Thermocouple/RTD 1794-IRT8 Thermocouple/RTD Module 126 Input Module Thermocouple/mV Input 1794-IT8 Thermocouple/mV Module 129 Module SCANport Module 1203-FM1 SCANport Module 132 Counters Frequency Input Module 1794-IJ2 2 Input Frequency Module 135 Power Supply For Information On Catalog Number Description See Page Very High Speed Counter Module 2-Channel Pulse Counter Input Module 4-Channel Pulse Counter Input Module 1794-VHSC 2 Channels Very High Speed Counter Module (Used with 1794-ACN15 or ACNR15 only) 1794-ID2 2 Input Pulse Counter Module IP4 12/ 4 Input Pulse Counter Module 145 Power Supply 1794-PS13 Power Supply Module 148 Accessories Accessories 1794-CE1 Extender Cable, 0.3m (1ft) CE3 Extender Cable, 0.9m (3ft) NM1 Mounting Kit CJC2 Cold Junction Compensator Kit LL Label Kit 151 RSWire Software 151 AECAD Software
10 10 Adapter s Table of Contents FLEX I/O and FLEX Integra Product Data $GDSWHU VÃ7DEOHÃRIÃ&RQWHQWV 8VHWKHIROORZLQJWDEOHWRGHWHUPLQHZKLFKDGDSWHUZLOOPHHW\RXU DSSOLFDWLRQQHHGV Adapter Purpose See Page 1794-ADN 1794-ACN ACNR15 Connects up to 8 I/O modules to the DeviceNet network Connects the FLEX I/O system to the ControlNet network Connects the FLEX I/O system to the ControlNet network with optional redundant media capability AS2/C Connects the FLEX I/O system (up to 2 modules) to the Remote I/O network 1794-AS/D Connects the FLEX I/O system (up to 8 modules) to the Remote I/O network 14 15
11 FLEX I/O and FLEX Integra Product Data DeviceNet Adapter Cat. No ADN 11 9ÃGFÃ'HYLFH1HWÃ$GDSWHUÃ&DWÃ1RÃ$'1 Wiring DeviceNet Connector Connect To LK Wire -V LU Wire CAN 1 Low are Wire Drain WHT Wire CAN High RED Wire V 1 CAN = Controller Area Network ATTENTION! D E COM 24V :KHQÃFRQQHFWLQJÃZLULQJÃWRUTXHÃWHUPLQDOÃVFUHZVÃ'Ã(Ã )ÃDQGÃ*ÃWRÃÃLQFKSRXQGV F G Specifications ADN I/O Capacity 8 modules Connector Screw Torque 7-9 inch-pounds Power Supply Note: In order to comply with CE Low Voltage Directives, you must use a Safety Extra Low Voltage (SELV) or a Protected Extra Low Voltage (PELV) power supply to power this adapter. Input Voltage Rating nominal Input Voltage Range 19.2V to 31.2V dc (includes 5% ac ripple) Communication Rate 125k bit/s 250k bit/s 500k bit/s Indicators Mod/Net status - red/grn I/O status - red/grn Flexbus Output Current 640mA 5V dc Isolation Voltage 500V ac for 1s between user power and flexbus Power Consumption 400mA maximum from external 24V supply Power Dissipation 7.6W 19.2V dc Thermal Dissipation V dc DeviceNet Power 90mA maximum Requirements DeviceNet Cable Allen-radley part no. 1485C-P1-Cxxx. Refer to publication DN-2.5 for more information. General Specifications Dimensions HxWxD 87mm x 68mm x 69mm (3.4in x 2.7in x 2.7in) Environmental Conditions Operational Temperature 0 to 55 o C (32 to 131 o F) Storage Temperature -40 to 85 o C (-40 to 185 o F) Relative Humidity 5 to 95% noncondensing ShockOperating 30g peak acceleration, 11(±1)ms pulse width Non-operating 50g peak acceleration, 11(±1)ms pulse width Vibration Tested Hz per IEC Power Conductors Type Wire Size Category Publications Installation Instructions User Manual Agency Certification Copper (stranded or solid) 12 gauge (4mm 2 ) stranded maximum 3/64 (1.2mm) inch insulation max Class I Division 2 certified Groups A,, C, D certified Class I Zone 2 Groups IIC certified 127(7KHÃZLULQJÃODEHOÃRQÃWKHÃIURQWÃRIÃWKHÃPRGXOHÃVKRZVÃWKHÃFDEOHÃFRORUV 1 Use this conductor category information for planning conductor routing. Refer to publication , Industrial Automation Wiring and Grounding Guidelines for Noise Immunity. &RQQHFWÃWKHÃ'HYLFH1HWÃFDEOHÃWRÃWKHÃUHPRYDEOHÃFRQQHFWRU,QVHUWÃFRQQHFWRUÃLQWRÃPDWLQJÃFRQQHFWRUÃRQÃ'HYLFH1HWÃDGDSWHUÃPRGXOH &RQQHFWÃ9ÃGFÃLQSXWÃWRÃWKHÃOHIWÃVLGHÃRIÃWKHÃORZHUÃFRQQHFWRUÃWHUPLQDOÃ( &RQQHFWÃ9ÃFRPPRQÃWRÃWKHÃOHIWÃVLGHÃRIÃWKHÃXSSHUÃFRQQHFWRUÃWHUPLQDOÃ' &RQQHFWLRQVÃ*ÃDQGÃ)ÃDUHÃXVHGÃWRÃSDVVÃ9ÃGFÃSRZHUÃDQGÃFRPPRQÃWRÃWKHÃ QH[WÃPRGXOHÃLQÃWKHÃVHULHVÃLIÃUHTXLUHG 6HWÃWKHÃQHWZRUNÃDGGUHVVÃXVLQJÃWKHÃSRVLWLRQÃWKXPEZKHHOÃVZLWFKÃ%Ã9DOLGÃ VHWWLQJVÃUDQJHÃIURPÃÃWRÃÃ3UHVVÃHLWKHUÃWKHÃÃRUÃÃEXWWRQVÃWRÃFKDQJHÃWKHÃ QXPEHU
12 12 ControlNet Adapter Cat. No ACN15 FLEX I/O and FLEX Integra Product Data 9ÃGFÃ&RQWURO1HWÃ$GDSWHUÃ&DWÃ1RÃ$&1 Wiring A ATTENTION! F Network Access Port (NAP) :KHQÃFRQQHFWLQJÃZLULQJÃWRUTXHÃWHUPLQDOÃVFUHZVÃ%Ã &Ã'ÃDQGÃ(ÃWRÃÃLQFKSRXQGV &RQQHFWÃWKHÃ&RQWURO1HWÃQHWZRUNÃFDEOHÃWRÃFRQQHFWRUÃWHUPLQDOÃ $Ã &RQQHFWÃ9ÃGFÃLQSXWÃWRÃWKHÃOHIWÃVLGHÃRIÃWKHÃORZHUÃFRQQHFWRUÃ WHUPLQDOÃ% &RQQHFWÃ9ÃFRPPRQÃWRÃWKHÃOHIWÃVLGHÃRIÃWKHÃXSSHUÃFRQQHFWRUÃ WHUPLQDOÃ& &RQQHFWLRQVÃ'ÃDQGÃ(ÃDUHÃXVHGÃWRÃSDVVÃ9ÃGFÃSRZHUÃ(ÃDQGÃ 9ÃFRPPRQÃ'ÃWRÃWKHÃQH[WÃPRGXOHÃLQÃWKHÃVHULHVÃLIÃ UHTXLUHG C D E Specifications ACN15 I/O Capacity 8 modules Connector Screw Torque 7-9 inch-pounds Power Supply Note: In order to comply with CE Low Voltage Directives, you must use a Safety Extra Low Voltage (SELV) or a Protected Extra Low Voltage (PELV) power supply to power this adapter. Input Voltage Rating nominal Input Voltage Range 19.2V to 31.2V dc (includes 5% ac ripple) Communication Rate 5M bit/s Supports Redundant No ControlNet Cabling Indicators Comm A - red/grn I/O Status - red/grn Programming Ports 1 RJ-45 Network Access Port (NAP) for use with ControlNet programming cable (e.g CP cable) Flexbus Output Current 640mA 5V dc Isolation Voltage 500V ac between user power and flexbus Power Consumption 400mA maximum from external 24V supply Power Dissipation 4.6W 19.2V dc Thermal Dissipation V dc General Specifications Dimensions HxWxD 87mm x 94mm x 69mm (3.4in x 3.7in x 2.7in) Environmental Conditions Operational Temperature Storage Temperature Relative Humidity Shock Operating Non-operating Vibration ControlNet Cable Power Conductors Type Wire Size Category Publication Installation Instructions Agency Certification 0 to 55 o C (32 to 131 o F) -40 to 85 o C (-40 to 185 o F) 5 to 95% noncondensing 30g peak acceleration, 11(±1)ms pulse width 50g peak acceleration, 11(±1)ms pulse width Tested Hz per IEC elden RG-6/U Quad Shield Copper (stranded or solid) 12 gauge (4mm 2 ) stranded maximum 3/64 (1.2mm) inch insulation max. 2 1 Class I Division 2 certified Groups A,, C, D certified Class I Zone 2 Group IIC certified 1 Use this conductor category information for planning conductor routing. Refer to publication , Industrial Automation Wiring and Grounding Guidelines for Noise Immunity. 6HWÃWKHÃQHWZRUNÃDGGUHVVÃXVLQJÃWKHÃSRVLWLRQÃWKXPEZKHHOÃ VZLWFKÃ)Ã9DOLGÃVHWWLQJVÃUDQJHÃIURPÃÃWRÃÃ3UHVVÃHLWKHUÃWKHÃÃ RUÃÃEXWWRQVÃWRÃFKDQJHÃWKHÃQXPEHU
13 FLEX I/O and FLEX Integra Product Data ControlNet Redundant Media Adapter Cat. No ACNR ÃGFÃ&RQWURO1HWÃ5HGXQGDQWÃ0HGLDÃ$GDSWHUÃ&DWÃ1RÃ$&15 Wiring A ATTENTION! G REDUNDANT MEDIA :KHQÃFRQQHFWLQJÃZLULQJÃWRUTXHÃWHUPLQDOÃVFUHZVÃ&Ã 'Ã(ÃDQGÃ)ÃWRÃÃLQFKSRXQGV &RQQHFWÃWKHÃ&RQWURO1HWÃQHWZRUNÃFDEOHÃWRÃFRQQHFWRUÃ$Ã &RQQHFWÃWKHÃUHGXQGDQWÃ&RQWURO1HWÃQHWZRUNÃFDEOHÃWRÃFRQQHFWRUÃ % :KHQÃXVLQJÃWKHÃ$&15ÃDVÃDÃVLQJOHÃFKDQQHOÃXVHÃFKDQQHOÃ $ 15 Network Access Port (NAP) C D E F Specifications ACNR15 I/O Capacity 8 modules Connector Screw Torque 7-9 inch-pounds Power Supply Note: In order to comply with CE Low Voltage Directives, you must use a Safety Extra Low Voltage (SELV) or a Protected Extra Low Voltage (PELV) power supply to power this adapter. Input Voltage Rating nominal Input Voltage Range 19.2V to 31.2V dc (includes 5% ac ripple) Communication Rate 5M bit/s Supports Redundant Yes ControlNet Cabling Indicators Comm A - red/grn (channel A) Comm - red/grn (channel ) I/O status - red/grn Programming Ports 1 RJ-45 Network Access Port (NAP) for use with ControlNet programming cable (e.g CP cable) Flexbus Output Current 640mA 5V dc Isolation Voltage 500V ac between user power and flexbus Power Consumption 400mA maximum from external 24V supply Power Dissipation 4.6W 19.2V dc Thermal Dissipation V dc General Specifications Dimensions HxWxD 87mm x 94mm x 69mm (3.4in x 3.7in x 2.7in) Environmental Conditions Operational Temperature Storage Temperature Relative Humidity Shock Vibration ControlNet Cable Power Conductors Type Wire Size Category Operating Non-operating Publication Installation Instructions Agency Certification 0 to 55 o C (32 to 131 o F) -40 to 85 o C (-40 to 185 o F) 5 to 95% noncondensing 30g peak acceleration, 11(±1)ms pulse width 50g peak acceleration, 11(±1)ms pulse width Tested Hz per IEC elden RG-6/U Quad Shield Copper (stranded or solid) 12 gauge (4mm 2 ) stranded maximum 3/64 (1.2mm) inch insulation max. 2 1 Class I Division 2 certified Groups A,, C, D certified Class I Zone 2 Group IIC certified &RQQHFWÃ9ÃGFÃLQSXWÃWRÃWKHÃOHIWÃVLGHÃRIÃWKHÃORZHUÃFRQQHFWRUÃ WHUPLQDOÃ' &RQQHFWÃ9ÃFRPPRQÃWRÃWKHÃOHIWÃVLGHÃRIÃWKHÃXSSHUÃFRQQHFWRUÃ WHUPLQDOÃ& &RQQHFWLRQVÃ(ÃDQGÃ)ÃDUHÃXVHGÃWRÃSDVVÃ9ÃGFÃSRZHUÃ)ÃDQGÃ 9ÃFRPPRQÃ(ÃWRÃWKHÃQH[WÃPRGXOHÃLQÃWKHÃVHULHVÃLIÃUHTXLUHG 6HWÃWKHÃQHWZRUNÃDGGUHVVÃXVLQJÃWKHÃSRVLWLRQÃWKXPEZKHHOÃ VZLWFKÃ*Ã9DOLGÃVHWWLQJÃUDQJHÃIURPÃÃWRÃÃ3UHVVÃHLWKHUÃWKHÃÃ RUÃÃEXWWRQVÃWRÃFKDQJHÃWKHÃQXPEHU 1 Use this conductor category information for planning conductor routing. Refer to publication , Industrial Automation Wiring and Grounding Guidelines for Noise Immunity.
14 14 Remote I/O Adapter (up to 2 modules) Cat. No AS2/C FLEX I/O and FLEX Integra Product Data Remote I/O Adapter (up to 2 modules) Cat. No AS2/C Wiring The series C adapter can communicate with FLEX Integra analog modules. ATTENTION! When connecting wiring, torque terminal screws D, E, F, and G to 7-9 inch-pounds. Connect the remote I/O cable to the removable remote I/O connector. Connect input to the left side of the lower connector, terminal (. Connect 24V common to the left side of the upper connector, terminal '. Connections * and ) are used to pass power (G) and 24V common (F) to the next module in the series (if required). Make wiring connections as described in the installation instructions included with the module that mounts on your terminal base unit. This adapter module is shipped configured for standard addressing mode. In standard addressing mode, this module can be used as a replacement for 1794-AS2/A 2-slot Remote I/O adapters. The 1794-AS2/C adapter module can interface a maximum of 2 I/O modules. This adapter can be used in the mode that requires a unique location address for each I/O module and can also be used in a mode that allows duplicate addressing of I/O modules. Duplicate addressing of I/O modules allows the maximum amount of I/O in a system for a given amount of I/O image area. An input module can have the same location address as an output module because they complement each other. The input module uses only the input image area corresponding to the address. The output module uses only the output image area corresponding to the address. Description of Modes Addressing Module Placement Rules Type Standard 2 terminal bases per adapter Each terminal base represents 1 I/O group Compact 16-point addressing 1 SH2 Compact 8-point addressing digital modules 2 terminal bases per adapter Each module represents 1/2 of an I/O group 2 modules represent 1 I/O group Do not place the 1794-I8 next to an output module. If this combination is used the AS will fault. D E COM 24V Legal Module Placements Any module in any slot A 16-point input module and a 16-point output module in an I/O group Not applicable F G Description of Modes (continued) Compact Not applicable Not applicable 8-point addressing analog modules Complementary 16-point addressing Complementary 8-point addressing 2 terminal bases per adapter 2 modules, 1 in primary, and 1 in complement represent 1 I/O group 2 terminal bases per adapter 4 modules, 2 in the primary and 2 in the complement, represents 1 I/O group Any module in any I/O position of the primary chassis, input modules complemented by output modules, analog modules complemented by analog modules or empty base 2 inputs in a group complemented by 2 outputs 2 outputs in a group complemented by 2 inputs 2 block transfer modules complemented by 2 empty slots 1 block transfer module and 1 input in a group complemented by 1 empty slot and 1 output module Specifications AS2/C The 1794-AS2/C adapter cannot be used with PLC-2 processors. I/O Capacity 2 modules Power Supply Note: In order to comply with CE Low Voltage Directives, you must use a Safety Extra Low Voltage (SELV) or a Protected Extra Low Voltage (PELV) power supply to power this adapter. Input Voltage Rating nominal Input Voltage Range 19.2V to 31.2V dc (includes 5% ac ripple) Communication Rate 57.6, 115.2, 230.4k bit/s Indicators Adapter active - green Adapter fault - red, Local fault - red Flexbus Output Current 640mA maximum Isolation Voltage 500V ac between user power and flexbus Power Consumption 450mA maximum from external 24V supply Power Dissipation 4.6W 31.2V dc Thermal Dissipation V dc General Specifications Dimensions HxWxD 87mm x 68mm x 69mm (3.4in x 2.7in x 2.7in) Environmental Conditions Operational Temperature Storage Temperature Relative Humidity Shock Operating Non-operating Vibration Remote I/O Cable Power Conductors Wire Size Category Publication Installation Instructions User Manual Agency Certification 0 to 55 o C (32 to 131 o F) -40 to 85 o C (-40 to 185 o F) 5 to 95% noncondensing 30g peak acceleration, 11(±1)ms pulse width 50g peak acceleration, 11(±1)ms pulse width Tested Hz per IEC elden 9463 or equivalent as specified in A- Approved Vendor List, publication ICCG-2.2 A- pin connector part no gauge (4mm 2 ) stranded maximum 3/64 (1.2mm) inch insulation max Class I Division 2 certified Groups A,, C, D certified Class I Zone 2 Group IIC certified 1 Use this conductor category information for planning conductor routing. Refer to publication , Industrial Automation Wiring and Grounding Guidelines for Noise Immunity.
15 FLEX I/O and FLEX Integra Product Data Remote I/O Adapter (up to 8 modules) Cat. No AS/D 15 Remote I/O Adapter (up to 8 modules) Cat. No AS/D Wiring The series D adapter can communicate with FLEX Integra analog modules. ATTENTION! When connecting wiring, torque terminal screws D, E, F, and G to 7-9 inch-pounds. Connect the remote I/O cable to the removable remote I/O connector. Connect input to the left side of the lower connector, terminal (. Connect 24V common to the left side of the upper connector, terminal '. Connections * and ) are used to pass power (G) and 24V common (F) to the next module in the series (if required). Make wiring connections as described in the installation instructions included with the module that mounts on your terminal base unit. The 1794-AS adapter module can interface a maximum of 8 I/O modules. This adapter can be used in the mode that requires a unique location address for each I/O module and can also be used in a mode that allows duplicate addressing of I/O modules. Duplicate addressing of I/O modules allows the maximum amount of I/O in a system for a given amount of I/O image area. An input module can have the same location address as an output module because they complement each other. The input module uses only the input image area corresponding to the address. The output module uses only the output image area corresponding to the address. Description of Modes Addressing Module Placement Rules Type Standard 8 terminal bases per adapter Each terminal base represents 1 I/O group Compact 16-point addressing 1 SH2 Compact 8-point addressing digital modules 8 terminal bases per adapter Each module represents 1/2 of an I/O group 2 modules represent 1 I/O group 8 modules = 1/2 I/O rack 8 terminal bases per adapter Each module represents 1/4 of an I/O group 4 modules represent 1 I/O group Do not place the 1794-I8 next to an output module. If this combination is used the AS will fault. D E COM 24V Legal Module Placements Any module in any slot A 16-point input module and a 16-point output module in an I/O group Two 8-point input modules and two 8-point output modules in an I/O group Module type must alternate within an I/O group: input, output, etc. F G Description of Modes (continued) Compact 8-point addressing analog modules Complementary 16-point addressing Complementary 8-point addressing 8 terminal bases per adapter Two block transfer modules Each module and adjacent and their adjacent empty base empty base represents 1/2 of = 1 I/O group - An empty slot an I/O group must accompany each block transfer module in 8-point compact addressing 8 terminal bases per adapter 2 modules, 1 in primary, and 1 in complement represent 1 I/O group 8 terminal bases per adapter 4 modules, 2 in the primary and 2 in the complement, represents 1 I/O group Any module in any I/O position of the primary chassis, input modules complemented by output modules, analog modules complemented by analog modules or empty base 2 inputs in a group complemented by 2 outputs 2 outputs in a group complemented by 2 inputs 2 block transfer modules complemented by 2 empty slots 1 block transfer module and 1 input in a group complemented by 1 empty slot and 1 output module Specifications AS/D The 1794-AS/D adapter cannot be used with PLC-2 processors. I/O Capacity 8 modules Power Supply Note: In order to comply with CE Low Voltage Directives, you must use a Safety Extra Low Voltage (SELV) or a Protected Extra Low Voltage (PELV) power supply to power this adapter. Input Voltage Rating nominal Input Voltage Range 19.2V to 31.2V dc (includes 5% ac ripple) Communication Rate 57.6, 115.2, 230.4k bit/s Indicators Adapter active - green Adapter fault - red, Local fault - red Flexbus Output Current 640mA maximum Isolation Voltage 500V ac between user power and flexbus Power Consumption 450mA maximum from external 24V supply Power Dissipation 4.6W 31.2V dc Thermal Dissipation V dc General Specifications Dimensions HxWxD 87mm x 68mm x 69mm (3.4in x 2.7in x 2.7in) Environmental Conditions Operational Temperature Storage Temperature Relative Humidity Shock Vibration Remote I/O Cable Power Conductors Wire Size Category Operating Non-operating Publication Installation Instructions User Manual Agency Certification 0 to 55 o C (32 to 131 o F) -40 to 85 o C (-40 to 185 o F) 5 to 95% noncondensing 30g peak acceleration, 11(±1)ms pulse width 50g peak acceleration, 11(±1)ms pulse width Tested Hz per IEC elden 9463 or equivalent as specified in A- Approved Vendor List, publication ICCG-2.2 A- pin connector part no gauge (4mm 2 ) stranded maximum 3/64 (1.2mm) inch insulation max Class I Division 2 certified Groups A,, C, D certified Class I Zone 2 Group IIC certified 1 Use this conductor category information for planning conductor routing. Refer to publication , Industrial Automation Wiring and Grounding Guidelines for Noise Immunity.
16 16 FLEX I/O Terminal ase Unit s Table of Contents FLEX I/O and FLEX Integra Product Data )/(;Ã,2Ã7HUPLQDOÃ%DVHÃ8QLW VÃ7DEOHÃRIÃ&RQWHQWV 8VHWKHIROORZLQJWDEOHWRGHWHUPLQHZKLFK)/(;,2WHUPLQDOEDVH XQLWZLOOPHHW\RXUDSSOLFDWLRQQHHGV Terminal ase Purpose See Page 1794-T2 A generic version of the 1794-T3 below T T3S 1794-T3T Primarily intended for use with input modules when using 3-wire input proximity switches - can also be used with output modules A spring clamp version of the cage clamp 1794-T3 above - provides faster, simpler wire installation Required with the 1794-IT8 module (when used in thermocouple mode) - also provides chassis ground connections for the 1794-IR8 and analog modules T3TS A spring clamp version of the 1794-T3T T3G A screw clamp terminal base unit with individual grounding used with certain analog modules T3GS A spring clamp version of the 1794-T3G TN 1794-TNF Provides screw terminals to accept larger gauge wires plus cover for I/O wiring Provides 8 5x20mm fuses, screw terminals, plus a cover for I/O wiring - shipped with fuses for the 1794-OA8 module; can be used to fuse the 1794-OM8 and -OW8 modules with a replacement fuse (see the installation instructions) F1 Required with the 1203-FM1 module 29
17 FLEX I/O and FLEX Integra Product Data FLEX I/O Terminal ase Compatibility Cross-Reference 17 )/(;Ã,2Ã7HUPLQDOÃ%DVHÃ&RPSDWLELOLW\Ã&URVV5HIHUHQFH 7KHIROORZLQJWDEOHLOOXVWUDWHVWKHUHFRPPHQGHG)/(;,2WHUPLQDOEDVH XQLWVIRUHDFKPRGXOH0DQ\WHUPLQDOEDVHXQLWVFDQEHXVHGZLWKPRVW PRGXOHVEXWDX[LOLDU\WHUPLQDOVWULSVPD\EHUHTXLUHG FLEX I/O Product Catalog Number Recommended ase Compatible ase(s) AC 120V ac Modules 1794-IA IA8I TN T3 T3S T2 TN T3 T3S T IA OA8 T3 T3S TN Auxiliary terminal strips are required when using the TN for the IA16 TNF T3 T3S TN T OA8I TNF T3 T3S TN T2 220V ac Modules 1794-OA IM OM8 T3 T3S T2 TN TN None Auxiliary terminal strips are required when using the TN for the OA16 TN TNF DC Modules 1794-I8 T3 T3S 1794-I16 T3 T3S 1794-IV16 T2 T3 T3S 1794-O8 T2 T3 T3S 1794-O16 T2 T3 T3S 1794-O16P T2 T3 T3S 1794-OV16 T3 T3S 1794-OV16P T3 T3S
18 18 FLEX I/O Terminal ase Compatibility Cross-Reference FLEX I/O and FLEX Integra Product Data FLEX I/O Product Catalog Number Recommended ase Compatible ase(s) DC Modules 1794-O8EP 1794-I10XO6 T3 T3S TN T2 T3 T3S 48V dc Modules 1794-IC16 T3 T3S 1794-OC16 T3 T3S T2 Analog Modules 1794-IE8/ T3 T3S T2 T3T T3TS 1794-OE4/ T3 T3S T2 T3T T3TS TN 1794-IE4XOE2/ T3 T3S T2 T3T T3TS Isolated Analog Source Modules 1794-IF4I T3 T3S T2 T3T T3TS TN 1794-OF4I T3 T3S T2 T3T T3TS TN 1794-IF2XOF2I T3 T3S T2 T3T T3TS TN Relay Relay Module 1794-OW8 TNF T3 T3S T2 TN Specialty RTD Input Module 1794-IR8 T3 T3S T2 T3T T3TS Thermocouple/RTD Input Module 1794-IRT8 T3G T3GS Thermocouple/mV Input Module SCANport Module 1794-IT FM1 T3T T3 T3S T2 T3TS You can use a T2, T3, or T3S for mv inputs only. F1 Counter Frequency Input Module 1794-IJ2 T3G T3GS Very High Speed Counter Module 1794-VHSC T3G T3GS For use with 1794-ACN(R)15 only. 2 Channel Pulse Counter Input Module 4 Channel Pulse Counter Input Module 1794-ID IP4 T3 T3S TN TNF T3 T3S TN TNF Auxiliary terminal strips are required when using the TN or TNF for the ID2 Auxiliary terminal strips are required when using the TN or TNF for the IP4
19 FLEX I/O and FLEX Integra Product Data 2-Wire Screw Clamp Terminal ase Unit Cat. No T2 19 :LUHÃ6FUHZÃ&ODPSÃ7HUPLQDOÃ%DVHÃ8QLWÃ&DWÃ1RÃ7% 1794-T2 A 0-15 COM COM V V C 34 & 51 V =, 120V ac, or 48V dc COM = common, 120V ac common, or 48V dc common A - 0 through through 33 C - 34 and 51 ATTENTION! Daisy-chaining Using Adapter Power Supply Daisy-chaining with a Separate Power Supply or 120V ac 1794-T2 Terminal ase Unit Input/Output Common, 120V ac Common, or 48V dc Common Power, 120V ac, or 48V dc 0DNHÃFHUWDLQÃWKDWÃWKHÃKRRNÃRQÃWKHÃWHUPLQDOÃEDVHÃ\RXÃ DUHÃLQVWDOOLQJÃLVÃSURSHUO\ÃKRRNHGÃLQWRÃWKHÃDGMDFHQWÃ WHUPLQDOÃEDVHDGDSWHUÃ)DLOXUHÃWRÃORFNÃWKHÃKRRNÃLQWRÃ WKHÃDGMDFHQWÃEDVHDGDSWHUÃFDQÃUHVXOWÃLQÃORVVÃRIÃ FRPPXQLFDWLRQÃRQÃWKHÃEDFNSODQH 'RÃQRWÃIRUFHÃWKHÃWHUPLQDOÃEDVHÃLQWRÃWKHÃDGMDFHQWÃ EDVHDGDSWHUÃ)RUFLQJÃWKHÃXQLWVÃWRJHWKHUÃFDQÃEHQGÃRUÃ EUHDNÃWKHÃKRRNÃDQGÃDOORZÃWKHÃXQLWVÃWRÃVHSDUDWHÃDQGÃ EUHDNÃFRPPXQLFDWLRQÃRYHUÃWKHÃEDFNSODQH Use this method when wiring all digital modules and total current draw through terminal base units is less than 10A. Wiring when total current draw is less than 10A Use this method when wiring all ac digital modules and total current draw through terminal base units is less than 10A Wiring when total current draw is less than 10A Separate power supply can be brought in on last module in chain if necessary. Make sure you do not jumper to adapter if using this method Individually Powered from Separate Power Supply, 120V ac, or 48V dc or 48V dc Combination Daisy-chain and Separate Power Supply Specifications T2 Number of Terminals 1 row of 16 1 row of 18 1 row of 2 Terminal Screw Torque 7-9 inch-pounds Current Capacity 10A maximum Voltage Rating 132V ac maximum Isolation Voltage Channel-to-channel isolation determined by inserted module (see publication ) General Specifications Dimensions (with module 94mm x 94mm x 69mm (3.7in x 3.7in x 2.7in) installed in base) HxWxD Environmental Conditions Operational Temperature Storage Temperature Relative Humidity Shock Operating Non-operating Vibration Conductors Wire Size Category Publication Installation Instructions Agency Certification Note: Use this configuration if using any noisy dc digital I/O modules in your system. Thermocouple Module wiring is separate from digital wiring. Wiring when total current draw is greater than 10A Separate power supply can be brought in on last module in chain if necessary. Make sure you do not jumper to adapter if using this method. Use this method when wiring both digital and analog modules. Analog modules must be wired separately from noisy digital modules. Total current draw through any base unit must not be greater than 10A Separate power supply can be brought in on last module in chain if necessary. Make sure you do not jumper to adapter if using this method. 0 to 55 o C (32 to 131 o F) -40 to 85 o C (-40 to 185 o F) 5 to 95% noncondensing 30g peak acceleration, 11(±1)ms pulse width 50g peak acceleration, 11(±1)ms pulse width Tested Hz per IEC gauge (4mm 2 ) stranded maximum 22 gauge (0.35mm 2 ) minimum 3/64 inch (1.2mm) insulation maximum Class I Division 2 certified Groups A,, C, D certified Class I Zone 2 Group IIC certified 1 Use this conductor category information for planning conductor routing. Refer to publication , Industrial Automation Wiring and Grounding Guidelines for Noise Immunity.
20 20 3-Wire Screw Clamp Terminal ase Unit Cat. No T3 FLEX I/O and FLEX Integra Product Data :LUHÃ6FUHZÃ&ODPSÃ7HUPLQDOÃ%DVHÃ8QLWÃ&DWÃ1RÃ7% 1794-T3 A - 0 through through 33 C - 34 through 51 ATTENTION! COM V COM V V =, 120V ac, or 48V dc COM = common, 120V ac common, or 48V dc common Daisy-chaining Using Adapter Power Supply Daisy-chaining with a Separate Power Supply or 120V ac 1794-T3 Terminal ase Unit Input/Output Common, 120V ac Common, or 48V dc Common Power, 120V ac, or 48V dc 0DNHÃFHUWDLQÃWKDWÃWKHÃKRRNÃRQÃWKHÃWHUPLQDOÃEDVHÃ\RXÃ DUHÃLQVWDOOLQJÃLVÃSURSHUO\ÃKRRNHGÃLQWRÃWKHÃDGMDFHQWÃ WHUPLQDOÃEDVHDGDSWHUÃ)DLOXUHÃWRÃORFNÃWKHÃKRRNÃLQWRÃ WKHÃDGMDFHQWÃEDVHDGDSWHUÃFDQÃUHVXOWÃLQÃORVVÃRIÃ FRPPXQLFDWLRQÃRQÃWKHÃEDFNSODQH 'RÃQRWÃIRUFHÃWKHÃWHUPLQDOÃEDVHÃLQWRÃWKHÃDGMDFHQWÃ EDVHDGDSWHUÃ)RUFLQJÃWKHÃXQLWVÃWRJHWKHUÃFDQÃEHQGÃRUÃ EUHDNÃWKHÃKRRNÃDQGÃDOORZÃWKHÃXQLWVÃWRÃVHSDUDWHÃDQGÃ EUHDNÃFRPPXQLFDWLRQÃRYHUÃWKHÃEDFNSODQH Use this method when wiring all digital modules and total current draw through terminal base units is less than 10A. Wiring when total current draw is less than 10A Use this method when wiring all ac digital modules and total current draw through terminal base units is less than 10A. A C Wiring when total current draw is less than 10A Separate power supply can be brought in on last module in chain if necessary. Make sure you do not jumper to adapter if using this method Individually Powered from Separate Power Supply, 120V ac, or 48V dc or 48V dc Combination Daisychain and Separate Power Supply Specifications T3 Number of Terminals 1 row of 16 2 rows of 18 Terminal Screw Torque 7-9 inch-pounds Current Capacity 10A maximum Voltage Rating 132V ac maximum Isolation Voltage Channel-to-channel isolation determined by inserted module (see publication ) General Specifications Dimensions (with module 94mm x 94mm x 69mm (3.7in x 3.7in x 2.7in) installed in base) HxWxD Environmental Conditions Operational Temperature Storage Temperature Relative Humidity Shock Operating Non-operating Vibration Conductors Wire Size Category Publication Installation Instructions Agency Certification Note: Use this configuration if using any noisy dc digital I/O modules in your system. Thermocouple Module wiring is separate from digital wiring. Wiring when total current draw is greater than 10A Separate power supply can be brought in on last module in chain if necessary. Make sure you do not jumper to adapter if using this method. Use this method when wiring both digital and analog modules. Analog modules must be wired separately from noisy digital modules. Total current draw through any base unit must not be greater than 10A Separate power supply can be brought in on last module in chain if necessary. Make sure you do not jumper to adapter if using this method. 0 to 55 o C (32 to 131 o F) -40 to 85 o C (-40 to 185 o F) 5 to 95% noncondensing 30g peak acceleration, 11(±1)ms pulse width 50g peak acceleration, 11(±1)ms pulse width Tested Hz per IEC gauge (4mm 2 ) stranded maximum 22 gauge (0.35mm 2 ) minimum 3/64 inch (1.2mm) insulation maximum Class I Division 2 certified Groups A,, C, D certified Class I Zone 2 Group IIC certified 1 Use this conductor category information for planning conductor routing. Refer to publication , Industrial Automation Wiring and Grounding Guidelines for Noise Immunity.
21 FLEX I/O and FLEX Integra Product Data 3-Wire Spring Clamp Terminal ase Unit Cat. No T3S 21 :LUHÃ6SULQJÃ&ODPSÃ7HUPLQDOÃ%DVHÃ8QLWÃ&DWÃ1RÃ7% T3S Individually Powered from Separate Power Supply, 120V ac, or 48V dc or 48V dc Note: Use this configuration if using any noisy dc digital I/O modules in your system. Thermocouple Module wiring is separate from digital wiring A C Combination Daisychain and Separate Power Supply Wiring when total current draw is greater than 10A Separate power supply can be brought in on last module in chain if necessary. Make sure you do not jumper to adapter if using this method A - 0 through through 33 C - 34 through 51 ATTENTION! Daisy-chaining Using Adapter Power Supply Daisy-chaining with a Separate Power Supply 1794-T3S Terminal ase Unit Input/Output Common, 120V ac Common, or 48V dc Common Power, 120V ac, or 48V dc 0DNHÃFHUWDLQÃWKDWÃWKHÃKRRNÃRQÃWKHÃWHUPLQDOÃEDVHÃ\RXÃ DUHÃLQVWDOOLQJÃLVÃSURSHUO\ÃKRRNHGÃLQWRÃWKHÃDGMDFHQWÃ WHUPLQDOÃEDVHDGDSWHUÃ)DLOXUHÃWRÃORFNÃWKHÃKRRNÃLQWRÃ WKHÃDGMDFHQWÃEDVHDGDSWHUÃFDQÃUHVXOWÃLQÃORVVÃRIÃ FRPPXQLFDWLRQÃRQÃWKHÃEDFNSODQH 'RÃQRWÃIRUFHÃWKHÃWHUPLQDOÃEDVHÃLQWRÃWKHÃDGMDFHQWÃ EDVHDGDSWHUÃ)RUFLQJÃWKHÃXQLWVÃWRJHWKHUÃFDQÃEHQGÃRUÃ EUHDNÃWKHÃKRRNÃDQGÃDOORZÃWKHÃXQLWVÃWRÃVHSDUDWHÃDQGÃ EUHDNÃFRPPXQLFDWLRQÃRYHUÃWKHÃEDFNSODQH Use this method when wiring all digital modules and total current draw through terminal base units is less than 10A. Wiring when total current draw is less than 10A Use this method when wiring both digital and analog modules. Analog modules must be wired separately from noisy digital modules. Note: All modules powered by the same power supply must be analog modules for this configuration. Total current draw through any base unit must not be greater than 10A Specifications T3S Number of Terminals 1 row of 16 2 rows of 18 Terminal Type Spring-clamp - To open, insert bladed screwdriver ( in/ mm) and lift up. Current Capacity 10A maximum Voltage Rating 132V ac maximum Isolation Voltage Channel-to-channel isolation determined by inserted module (see publication ) General Specifications Dimensions (with module 94mm x 94mm x 69mm (3.7in x 3.7in x 2.7in) installed in base) HxWxD Environmental Conditions Operational Temperature Storage Temperature Relative Humidity Shock Operating Non-operating Vibration Conductors Wire Size Category Publication Installation Instructions Agency Certification Separate power supply can be brought in on last module in chain if necessary. Make sure you do not jumper to adapter if using this method. 0 to 55 o C (32 to 131 o F) -40 to 85 o C (-40 to 185 o F) 5 to 95% noncondensing 30g peak acceleration, 11(±1)ms pulse width 50g peak acceleration, 11(±1)ms pulse width Tested Hz per IEC gauge (4mm 2 ) stranded maximum, 22 gauge (0.35mm 2 ) minimum 3/64 inch (1.2mm) insulation maximum (Established by inserted module.) or 120V ac Use this method when wiring all ac digital modules and total current draw through terminal base units is less than 10A. Wiring when total current draw is less than 10A Separate power supply can be brought in on last module in chain if necessary. Make sure you do not jumper to adapter if using this method Class I Division 2 certified Groups A,, C, D certified Class I Zone 2 Group IIC certified 1 Use this conductor category information for planning conductor routing. Refer to publication , Industrial Automation Wiring and Grounding Guidelines for Noise Immunity.
22 22 Screw Clamp Temperature Terminal ase Unit Cat. No T3T FLEX I/O and FLEX Integra Product Data 6FUHZÃ&ODPSÃ7HPSHUDWXUHÃ7HUPLQDOÃ%DVHÃ8QLWÃ&DWÃ1RÃ7% T3T The temperature terminal base has connections for cold junction compensation, and 8 terminals designated for shield termination to chassis ground. Wiring 1794-T3T Terminal ase Unit Channel High Sig () Low Sig (-) Sig Ret Reserved Shld Ret (C) 18(N0) (C) 20(N1) (C) 22(N2) (C) 24(N3) (C) 26(N4) (C) 28(N5) (C) 30(N6) (C) 32(N7) 46 Common 16, 17, 19, 21, 23, 25, 27, 29, 31, and 33 power 34, 35, 50, and 51 Terminals and are used with cold junction compensators only. 1 Terminals are chassis ground. ATTENTION! Daisy-chaining Using Adapter Power Supply C C N0 C N1 C N2 C N3 C N4 C N5 C N6 C N7 C V C J C C J C V = chassis ground V = N = add. input C = common CJC = cold junction compensation RWDOÃFXUUHQWÃGUDZÃWKURXJKÃWKHÃWHUPLQDOÃEDVHÃXQLWÃLVÃ OLPLWHGÃWRÃ$Ã6HSDUDWHÃSRZHUÃFRQQHFWLRQVÃPD\ÃEHÃ QHFHVVDU\ 'RÃQRWÃGDLV\ÃFKDLQÃSRZHUÃRUÃJURXQGÃIURPÃWKHÃ WKHUPRFRXSOHÃWHUPLQDOÃEDVHÃXQLWÃWRÃDQ\ÃDFÃRUÃGFÃ GLJLWDOÃPRGXOHÃWHUPLQDOÃEDVHÃXQLW 0DNHÃFHUWDLQÃWKDWÃWKHÃKRRNÃRQÃWKHÃWHUPLQDOÃEDVHÃ\RXÃ DUHÃLQVWDOOLQJÃLVÃSURSHUO\ÃKRRNHGÃLQWRÃWKHÃDGMDFHQWÃ WHUPLQDOÃEDVHÃDGDSWHUÃ)DLOXUHÃWRÃORFNÃWKHÃKRRNÃLQWRÃ WKHÃDGMDFHQWÃEDVHDGDSWHUÃFDQÃUHVXOWÃLQÃORVVÃRIÃ FRPPXQLFDWLRQÃRQÃWKHÃEDFNSODQH 'RÃQRWÃIRUFHÃWKHÃWHUPLQDOÃEDVHÃLQWRÃWKHÃDGMDFHQWÃ EDVHDGDSWHUÃ)RUFLQJÃWKHÃXQLWVÃWRJHWKHUÃFDQÃEHQGÃRUÃ EUHDNÃWKHÃKRRNÃDQGÃDOORZÃWKHÃXQLWVÃWRÃVHSDUDWHÃDQGÃ EUHDNÃFRPPXQLFDWLRQÃRYHUÃWKHÃEDFNSODQH thermocouple or analog module thermocouple or analog module A thermocouple or analog module C Note: All modules must be analog or thermocouple modules for this configuration. Use this method when wiring all analog modules and total current draw through terminal base units is less than 10A. Wiring when total current draw is less than 10A thermocouple or analog module Daisy-chaining with a Separate Power Supply Specifications T3T Number of Terminals 1 row of 16; 2 rows of 18 Terminal Screw Torque 7-9 inch-pounds Current Capacity 10A maximum Voltage Rating 132V ac maximum Isolation Voltage Ch-to-ch isolation determined by inserted mod General Specifications Dimensions (w/mod in base) 94mm x 94mm x 69mm (3.7in x 3.7in x 2.7in) Environmental Conditions Operational Temperature Storage Temperature Relative Humidity Shock Vibration Conductors, 48V dc or 120V ac Use this method when mixing digital modules and analog modules and total current draw through terminal base units is greater than 10A. Individually Powered from Separate Power Supply Combination Daisychain and Separate Power Supply Operating Non-operating Wire Size discrete module Category Publication Installation Instructions Agency Certification thermocouple or analog module discrete module Thermocouple module wiring separate from discrete wiring Note: Use this configuration if using any noisy dc discrete I/O modules in your system. Wiring when total current draw is greater than 10A Separate power supply can be brought in on last module in chain if necessary. Make sure you do not jumper to adapter if using this method thermocouple or analog module thermocouple or analog module thermocouple or analog module 0 to 55 o C (32 to 131 o F) -40 to 85 o C (-40 to 185 o F) 5 to 95% noncondensing 30g peak acceleration, 11(±1)ms pulse width 50g peak acceleration, 11(±1)ms pulse width Tested Hz per IEC gauge (4mm 2 ) stranded maximum 22 gauge (0.35mm 2 ) minimum 3/64 inch (1.2mm) insulation maximum (Established by inserted module.) 1 discrete module thermocouple or analog module Note: All modules must be analog modules in this configuration. Total current draw through any base unit must not be greater than 10A Separate power supply can be brought in on last module in chain if necessary. Make sure you do not jumper to adapter if using this method or 120V ac Use this method when wiring both digital and analog modules. Analog modules must be wired separately from noisy digital modules. Note: All modules powered by the same power supply must be analog modules for this configuration. Wiring when total current draw is less than 10A Separate power supply can be brought in on last module in chain if necessary. Make sure you do not jumper to adapter if using this method Class I Division 2 certified Groups A,, C, D certified Class I Zone 2 Group IIC certified 1 Use this conductor category information for planning conductor routing. Refer to publication , Industrial Automation Wiring and Grounding Guidelines for Noise Immunity.
Analog I/O Module Summary
36 Select FLEX I/O Modules Analog I/O Module Summary Catalog Number Inputs Outputs Terminal Base Unit Module Type 1794-IE8 8 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3T, Selectable, non-isolated inputs 1794-IE8XT
More information8 Input/8 Output AC Block I/O Module
8 Input/8 Output AC Module Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through the block module.
More information24V dc Analog Block I/O Module
24V dc Analog Module Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through the block module. Refer
More informationSpecifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift
Appendix A Specifications 1797-IE8 and -IE8NF Input Modules Specifications Number of Inputs IS Input Type IS Module Type Resolution Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Functional
More informationAllen-Bradley Automation
FLEX Integra I/O (atalog Number 793) Product Data 4868 4869 Flexible, inexpensive, and compact. FLEX Integra is a flexible, low-cost, small increment, modular I/O system for distributed applications that
More informationCompactLogix 5370 L3 Control System
CompactLogix 5370 Controllers CompactLogix 5370 L1 Control System CompactLogix 5370 L2 Control System CompactLogix 5370 L3 Control System CompactLogix 5370 controllers provide scalable controller solutions
More informationFLEX I/O Frequency Input Module. Catalog Numbers 1794-IJ2, 1794-IJ2K, 1794-IJ2XT User Manual
FLEX I/O Frequency Input Module Catalog Numbers 1794-IJ2, 1794-IJ2K, 1794-IJ2XT User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical
More informationFC Series Signal Conditioners
FC Series Signal Conditioners FC-33 DC Selectable Signal Conditioner with 3-way isolation Field configurable input and output ranges of 0-5V, 0-10 V, 0-20 ma and 4-20 ma with 1500 VDC isolation between
More information1715 Redundant I/O System Specifications
Technical Data 1715 Redundant I/O System Specifications System Module Catalog Numbers 1715-AENTR, 1715-IB16D, 1715-OB8DE,1715-IF16, 1715-OF8I Base Unit Catalog Numbers 1715-A2A, 1715-A3IO Termination Assembly
More information1769 Compact I/O Modules Specifications
Technical Document 1769 Compact I/O Modules Specifications Catalog Numbers 1769 Series Topic Page Summary of Changes 2 I/O Module Overview 2 Place Compact I/O Modules 4 Digital I/O Modules 5 Analog I/O
More informationXM Monitoring Modules Specifications
Technical Data XM Monitoring Modules Specifications Catalog Numbers 1440 series The XM series of intelligent I/O modules process, in real-time, the critical parameters used to assess the current health
More informationFOUNDATION Fieldbus Junction Box
Installation Instructions FOUNDATION Fieldbus Junction Box Catalog Number 1788-FBJB4R, 1788-FBJB6 Topic Page Important User Information 2 About the Junction Boxes 3 Additional Resources 3 Installation
More information1769 Compact I/O Modules Specifications
Technical Data 1769 Compact I/O Modules Specifications Catalog Numbers 1769 series Topic Page Available 1769 I/O Modules 4 Digital I/O Modules 6 Analog I/O Modules 7 Specialty I/O Modules 8 Module Specifications
More informationS200 I/O System Units
S200 I/O System Units S200 I/O is a range of cost effective I/O units which are bus compatible with S200L I/O and can be mixed with them in any order on the same DIN rail. The S200 I/O System features
More informationSLC 500 System Overview
SLC 500 System Overview The Allen-Bradley SLC 500 is a small chassis-based family of programmable controllers, discrete, analog, and specialty I/O, and peripheral devices. The SLC 500 family delivers power
More informationFLEX Ex Power Supplies
Installation Instructions FLEX Ex Power Supplies (Cat. Nos. 1797-PS2N, -PS2E) About the Power Supplies The power supply is an essential component in the operation of an intrinsically safe system. It must
More information1715 Redundant I/O System Specifications
Technical Data 1715 Redundant I/O System Specifications System Module Catalog Numbers 1715-AENTR, 1715-IB16D, 1715-OB8DE,1715-IF16, 1715-OF8I Base Unit Catalog Numbers 1715-A2A, 1715-A3IO Termination Assembly
More informationTemperature Input Module for Zone 1 Series 9482/32
www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >
More informationPower Supplies 3. SDN-C Compact DIN Rail Series
SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual diagnostic LEDs
More informationInstallation Instructions
Installation Instructions ControlNet Modular Repeater Dual Copper Module Catalog Number This document describes how to install and apply the dual copper repeater module. Topic: Page: Important User Information
More informationDATA SHEET. CIO multi-inputs. CAN bus-based I/O module
DATA SHEET CAN bus-based I/O module 8 multi-functional inputs Selectable as: o Digital input, 0(4) to 20 ma, 0 to 10 V, RMI, Pt100, Pt1000, Thermocouple type E, J, K, N, R, S or T Wire break detection
More informationAllen-Bradley. User Manual. Very High Speed Counter Module. (Cat. No VHSC) Allen-Bradley Spares
1 Allen-Bradley Very High Speed Counter Module User Manual (Cat. No. 1794-VHSC) Allen-Bradley Spares Important User Information Because of the variety of uses for the products described in this publication,
More informationEngineering Guideline. pac-carriers Type for Yokogawa Centum VP
Engineering Guideline pac-carriers Type 9195 for Yokogawa Centum VP pac-carrier Type 9195 2 Engineering Guideline / Yokogawa Centum VP 26.0.2018 pac-carrier Type 9195 Integrated solutions for Yokogawa
More informationSLC 500 RTD/Resistance Input Modules
Technical Data SLC 500 RTD/Resistance Input Modules (Catalog Numbers 1746-NR4 and 1746-NR8) 1746-NR4 1746-NR8 Inside................... page Hardware Overview............. 2 Module Operation..............
More informationAnalog Universal Module HART for Zone 2 Series 9468/33
> 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on
More informationFLEX Ex V ac In/Quad-Ex dc Out Power Supply
Installation Instructions FLEX Ex 85 250V ac In/Quad-Ex dc Out Power Supply Catalog Number 1797-PS1N Topic Important User Information 2 About the Power Supplies 3 Understand System Planning 4 Electrostatic
More information- 1. Allen-Bradley. User Manual. Very High Speed Counter Module. (Cat. No VHSC)
- 1 Allen-Bradley Very High Speed Counter Module User Manual (Cat. No. 1794-VHSC) Important User Information Because of the variety of uses for the products described in this publication, those responsible
More informationModicon Momentum automation platform 0
Presentation, description Presentation The Momentum analog input bases enable acquisition of various analog values encountered in industrial applications, including: b b b b Standard high level (± 5 V,
More informationDigital Input Output Module 24 V for Ex n Zone 2 Series 9472/35
www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up
More informationFP-RTD-122. Features OPERATING INSTRUCTIONS. 8-Channel, 3-Wire RTD and Resistance Input Module
OPERATING INSTRUCTIONS FP-RTD-122 8-Channel, 3-Wire RTD and Resistance Input Module These operating instructions describe the installation, features, and characteristics of the FP-RTD-122. For details
More informationDigital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22
www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More information5069 Compact I/O Modules Specifications
Technical Data 5069 Compact I/O Modules Specifications Digital I/O Module Catalog Numbers 5069-IB16, 5069-IB16F, 5069-IB6F-3W, 5069-OB16, 5069-OB16F, 5069-OW4I, 5069-OX4I Analog I/O Module Catalog Numbers
More informationAllen-Bradley. User Manual. SLC 500 Analog I/O Modules. (Cat. Nos NI4, -NIO4I, -NIO4V, -NO4I, and -NO4V)
Allen-Bradley SLC 500 Analog I/O Modules (Cat. Nos. 1746-NI4, -NIO4I, -NIO4V, -NO4I, and -NO4V) User Manual Important User Information Because of the variety of uses for the products described in this
More informationDSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters
Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and
More informationAllen-Bradley Spares
FLEX Ex Technical Data 1797 Series Intrinsically Safe I/O Distributed Architecture FLEX Ex TM is a modular I/O system that mounts directly to the controlled equipment in the hazardous area This eliminates
More informationDigital Input Output Module for Zone 2 Series 9470/33
www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8
More informationAnalog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/
> 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationQUINT-PS/ 3AC/24DC/10
Primary-switched power supply with SFB technology, 3 AC, output current 10 A INTERFACE Data sheet 103131_en_01 1 Description PHOENIX CONTACT - 09/2009 Features QUINT POWER power supply units Maximum system
More informationQUINT-PS/ 3AC/24DC/40
Primary-switched power supply unit with SFB technology, 3 AC, output current 40 A INTERFACE Data sheet 103133_en_00 1 Description PHOENIX CONTACT - 07/2009 Features QUINT POWER power supply units Maximum
More informationPower supply CP-D 24/4.2 Primary switch mode power supply
Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution
More informationTRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:
Extract from the online catalog TRIO-PS/1AC/24DC/ 5 Order No.: 2866310 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 5 A Commercial data EAN 4046356046640 Pack 1 pcs. Customs
More information12 Input/12 Output Discrete Embedded TTL I/O Module with Pulse Width Modulation and DeviceLogix
Installation Instructions 12 Input/12 Output Discrete Embedded TTL I/O Module with Pulse Width Modulation and DeviceLogix Cat. No. 1799-D12G12GL Inside... For See page About the Module 1 Important User
More informationUniStream Uni-I/O Modules
UniStream Uni-I/O Modules Technical Specifications UIS-WCB1 This guide provides specifications for Unitronics Uni-I/O Wide module UIS-WCB1. This module comprises: 10 Digital inputs, 24VDC, sink/source,
More informationControlNet Accessory Specifications
Technical Data ControlNet Accessory Specifications Catalog Numbers 1786-RPA,, 1786-RPFM, 1786-RPFS, 1756-RPFRL, 1786-PRFRXL Topic Page 1786-RPA/B ControlNet Modular Repeater Adapter 2 ControlNet Dual Copper
More informationThis Errata Sheet contains corrections or changes made after the publication of this manual.
Errata Sheet This Errata Sheet contains corrections or changes made after the publication of this manual. Product Family: DL4 Date: September 12, 218 Manual Number D4-ANLG-M Revision and Date th Ed., Rev.
More informationMINI-PS AC/24DC/1.3
Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics
More information1769 Compact Discrete Input/Output Modules
Technical Data 1769 Compact (Bulletin 1769) &RPSDFW,2LVDQHZ3/&VW\OHSODWIRUPRIIHULQJLQGXVWU\OHDGLQJSULFHDQG SHUIRUPDQFH,WXWLOL]HVWKHODWHVWGHVLJQWHFKQRORJ\IRUVXSHULRUSHUIRUPDQFH H[FHOOHQWIXQFWLRQDOLW\DQGHDVHRIXVH
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More informationQUINT-PS AC/24DC/40
Power supply unit INTERFACE Data sheet 102315_en_02 1 Description PHOENIX CONTACT 2010-04-23 Features QUINT POWER power supply units for plant and special engineering reliably start heavy loads with high
More informationThe Allen-Bradley Servo Interface Module (Cat. No SF1) when used with the Micro Controller (Cat. No UC1) can control single axis
Table of Contents The Allen-Bradley Servo Interface Module (Cat. No. 1771-SF1) when used with the Micro Controller (Cat. No. 1771-UC1) can control single axis positioning systems such as found in machine
More informationF4-08RTD 8-Channel RTD Input
F-8RTD 8-Channel RTD 92 F8RTD 8-Channel RTD Module Specifications The F8RTD 8 Differential Channel RTD module provides several features and benefits. It provides eight RTD input channels with 16-bit resolution.
More informationPower supply CP-E 24/0.75
2CDC 271 016 F0t06 a OUTPUT L+, L : terminals output b INPUT L, N, PE: terminals input c LOW: red LED output voltage too low d OK: green LED output voltage OK e OUTPUT Adjust: rotary potentiometer output
More informationDigital Input Output Module for Zone 2 Series 9470/33
www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used
More informationMODEL: M6SXU MODEL: M6SXU [1][2] [3][4]
Tension-Clamp Ultra-Slim Signal Conditioners M6S Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection Universal input (mv, V, ma, T/C, RTD and potentiometer)
More informationNI REM Remote I/O Overview DATASHEET. Temperature Input Module for Remote I/O
DATASHEET NI REM-11120 Temperature Input Module for Remote I/O 4 thermocouple channels with input range of ±100 mv 1 voltage input channel with range of ±5V 24-bit resolution Optional external CJC or additional
More informationTRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type
TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type USER S MANUAL Contents 1. APPLICATION...5 2. TRANSDUCER SET...5 3. OPERATIONAL SAFETY...6 4. INSTALLATION...7 4.1. Fitting way...7 4.2. External
More information02/11/2015
Smart range with Removable Terminal blocks XD26RBT Smart Part number 88974561 Designed for industrial, commercial, medical and paramedical machines Faster maintenance process which improves the machine
More informationPHOENIX CONTACT
Electronic circuit breaker CLIPLINE Data sheet 102898_en_03 PHOENIX CONTACT 2010-12-17 1 Description The electronic circuit breaker can be used in applications that cover all aspects of the switched-mode
More informationCompact I/O RTD/Resistance Input Module
User Manual Compact I/O RTD/Resistance Input Module Catalog Number 1769-IR6 Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical equipment.
More informationHE693THM884/888 High Resolution Thermocouple Module Product Specifications and Installation
MAN0095-15-EN HE693THM884/888 High Resolution Thermocouple Module Product Specifications and Installation 1 DESCRIPTION The Horner APG High Resolution Thermocouple Input Module allows thermocouple temperature
More informationRelated Products SDP Series SFL Series SCP Series SCL Series SDU UPS
4 Power Supplies SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility
More informationFLEX Ex Thermocouple/RTD Input Module
Installation Instructions FLEX Ex Thermocouple/RTD Input Module Catalog Number 1797-IRT8 Contents For Information About See Page Important User Information 2 Module Installation 3 Installation in Zone
More informationPower supply CP-E 24/2.5
2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment
More informationDigital Input Output Module for Zone 1 Series 9470/32
www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used
More informationSmartBlock I/O Module - HE579DAC107/HE579DAC207 8/4 Channel Current and Voltage Output 0-5V / 0-10V / 4-20mA / 0-20mA - CsCAN
SmartBlock I/O Module - HE579DAC107/HE579DAC207 8/4 Channel Current and Voltage Output 0-5V / 0-10V / 4-20mA / 0-20mA - CsCAN 1. SPECIFICATIONS / DIMENSIONS ANALOG OUT Number of Outputs 8 (207) or 4 (107)
More informationDigital Input Module 24 V Ex n Inputs, 16 Channels Series 9471
> 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels
More informationPower supply CP-E 24/20.0
2CDC 271 027 F0008 a OUTPUT L+, L+, L, L-: terminals output b INPUT L, N, PE: terminals input c 13-14: terminals - signalling contact d OUTPUT OK: green LED output voltage OK e OUTPUT LOW: red LED output
More informationNotes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC
Features DIN-Rail 2 and 3-phase operation Input voltage range: 320 575VAC Output trim range: 22.5 29.5VDC High electrical strength; high reliability Permanent overload and short-circuit protection Parallel
More informationPACSystems* RX3i IC695ALG600-EE Universal Analog Input Module
June 2017 The PACSystems Universal Analog Input module IC695ALG600 provides eight general purpose input channels and two Cold Junction Compensation (CJC) channels. Inputs are divided into two equal groups
More information02/11/2015
Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.
More informationPower supply CP-D 12/2.1
2CDC 271 025 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 12 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 2.1 A Rated output power
More informationTBX-1329 AC/DC COUPLING TERMINAL BLOCK
INSTALLATION GUIDE TBX-1329 AC/DC COUPLING TERMINAL BLOCK Introduction This guide describes how to install and use the TBX-1329 AC/DC coupling terminal block with the SCXI-1120, SCXI-1120D, and SCXI-1121
More informationMINI MCR-SL-UI-I-LP-NC
2-way isolation amplifier Data sheet 105263_en_02 PHOENIX CONTACT 2013-12-13 1 Description The configurable 2-way isolation amplifiers are used to electrically isolate, convert and filter standard signals.
More informationNo-wear isolation of potentials in terminal block design
TERMOPTO Overview No-wear isolation of potentials in terminal block design Space saving solid-state relay with PUSH IN connection technology The TERMOPTO opto modules are characterised by a particularly
More informationSLC 500 Thermocouple/mV Analog Input Module
SLC 500 Thermocouple/mV Analog Input Module 1746-NT8 User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety
More informationB850 Boiler House Energy Monitor
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationQUINT-PS-24DC/24DC/10
QUINT-PS-24/24/10 QUINT - converter, primary switched mode, input: 24 V, output: 24 V /10 A INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description The QUINT - converter 24 V/10 A converts the voltage
More informationControlNet Ex Tap Terminator Installation Instructions
Installation Instructions Tap Terminator Installation Instructions (Cat No 1797-TCAP) Use this document as a guide when you install a ControlNet TM Ex tap terminator This document will be packaged with
More information2750 Integra Mainframes
Selector Guide Plug-In Modules for 700, 70, 70 Integra Mainframes Module Selector Guide This selector guide may prove helpful in identifying the best module for a specific application. Install up to five
More informationPower supply CP-D 24/1.3
2CDC 271 027 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 24 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 1.3 A Rated output power
More informationSwitched mode power supply for DIN rail mounting type SMP21 DC24V/10A
Switched mode power supply for DIN rail mounting type SMP2 DC24V/0A Description Switched mode power supply for rail mounting, with independent change-over of input voltages (AC 5/20 V), integral passive
More informationTemperature transmitter itemp PCP DIN rail TMT 121
Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage
More informationLDW240 Series are single, two or three phase DIN Rail Switching Power Supplies.
LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies. Its compact size, high efficiency, excellent reliability together with easy installation due to pluggable connectors makes
More informationDeviceNet Connector. Address Switches. Diagnostic LEDs. I/O Connectors. Power Connectors
DeviceNet piconet Stations TURCK s piconet DeviceNet stations are compact rugged stations designed for machine mounting. These stations allow easy connection of standard I/O devices such as sensors, limit
More informationUser's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters
User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance
More informationNotes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC
Features DIN-Rail Description 2 and 3-phase operation Input voltage range: 320 575VAC Output trim range: 22.5 29.5VDC High electrical strength; high reliability Permanent overload and short-circuit protection
More informationATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW
Characteristics soft starter for asynchronous motor - ATSU01-32 A - 200..480V - 7.5..15 KW Main Range of product Product or component type Product destination Product specific application Device short
More informationPower Supplies. SCL Series. Features. Related Products. Applications
SDN Series The SDN family of DIN Rail power supplies have industry leading performance with a true industrial grade design and high quality that meets difficult industrial environmental conditions including
More informationSensorLex 8B Isolated Analog Signal Conditioning Products. and D power. 7 to 34VDC 36V TVS, 1A Fuse, OV detection 35.5V max 6.
Accessories for 8B Analog Modules Features Single Channel DIN Rail Mounting Accessory 2-, 4-, 8-, 16-Position Backpanels Panel or DIN Rail Mounting Options 19-Inch Mounting Rack for Backpanels Interface
More information09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i
Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation
More informationFor non-electrical quantities
Controlgear 3UG3 monitoring relays 3RS17 interface converters N nsb0346h nsb0348h nsb0775h For electrical quantities For non-electrical quantities 3RS17 interface converter Selection and ordering data
More informationUser's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters
User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance
More informationAllen-Bradley. User Manual. SLC 500 Thermocouple/mV Analog Input Module. (Catalog Number 1746-NT8)
Allen-Bradley SLC 500 Thermocouple/mV Analog Input Module User Manual (Catalog Number 1746-NT8) Important User Information Because of the variety of uses for the products described in this publication,
More information3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.
Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe
More informationPower supply CP-E 24/2.5
2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment
More informationATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW
Characteristics soft starter for asynchronous motor - ATSU01-22 A - 200..480 V - 4..11 KW Price* : 195.00 GBP Main Range of product Product or component type Product destination Product specific application
More informationAnalog Modules AS-i IP20
(Figure similar) Figure Type Inputs analog 4... 20 ma / 4... 20 ma / 4... 20 ma Pt100 4 x thermocouple type J 4 x thermocouple type K Outputs analog 0... 20 ma / 0... 20 ma / -10 V... +10 V Input voltage
More informationSISNet Distance Extenders
April 2011 Page 1 Extend the DeltaV SIS remote peer ring with Dedicated safety communications Full communications redundancy Flexibility to meets project needs Consistent update rate Introduction The DeltaV
More informationBtdin RCD Add-on modules 63A for MCBs 1,5 modules per pole
Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics... 4 6. Compliance - Approvals... 6 7. Curves... 7 8. Auxiliares and
More informationPaperless Recorder PR20
Technical Information TI 075R/24/ae Paperless Recorder PR20 Economical and time saving recorder operates without the need for paper or pens and is exceedingly simple to operate Application Areas Technological
More information