Switches & Pilot Devices
|
|
- Everett Willis
- 6 years ago
- Views:
Transcription
1 ømm - HW Series Key features: ocking lever removable contact blocks Finger-safe IP0 contacts as standard, other terminal styles available Tamperproof construction All E-stops meet EN8 and are compliant with SEMI S standards Worldwide approvals Easy to assemble hoice of black plastic or metallic front bezels Incandescent or ED illumination or full voltage Slow make double break self cleaning contacts HW Series mm IE Global Pushbuttons IDE s HW switches are The best engineered switch in the world for a reason. arrying the E mark, U, SA, (hinese), and TUV approvals, these switches are designed for use in almost any part of the world. omplete with finger-safe contact blocks offering IP0 protection, these 7/8 (mm) switches include illuminated and non-illuminated pushbuttons, pilot Electrical File No. E6896 ated perational haracteristics Maximum Inrush urrent ated Insulation Voltage ated Switching ver-voltage ated Impulse Withstanding Voltage ated Thermal urrent Minimum Switching apacity Electrical eliability amp atings File No. 97 HW: The Best Engineered Switch in the World lights, selector switches, and emergency stop switches. All switches also incorporate mechanically keyed safety locking levers, ensuring correct installation and maintaining safety in high-vibration applications. egistration No (E-stops) egistration No (Dual Pushbuttons) egistration No. J96505 (Pilot ights) egistration No. J95558 (all other switches) Specifications A-5: A600 or Ue = 50V, le = A (N, N, N-EM, N-B) D-: P600 or Ue = 5V, le =.A (N, N) D-: Q600 or Ue = 5V, le = 0.9A (N-EM, N-B) 0 A (0 ms) 600V ess than kv, conforming to IE6097- kv for contact circuit,.5kv for lamp circuit 0 Amp 5 ma at V A/D MTBF < fault for 0 million operation cycles (V D, 5mA) Incandescent: W EDs: 6V/7mA max, V & V/mA max, 0 & /0mA max ertificate No Signaling ights elays & Sockets Timers ontactors Blocks ircuit Breakers IDE () USA & anada 59
2 ømm - HW Series Blocks ontactors Timers elays & Sockets Signaling ights haracteristics ontact atings Standards & Approvals Mechanical ircuit Breakers ontact peration Slow break N or N, self-cleaning 5.5mm to 0mm travel to latch, 5N minimum force to latch Positive Action peration 0mm maximum travel,,800 operations per hour maximum for a Pushlock Turn eset (Emergency Stops with N contacts) 900 operations per hour maximum for a Push-Pull perating Force Flush and extended pushbuttons with N or N contact: 6.±N (momentary), 7.0±N (maintained) Additional contacts N or N:.N (momentary),.n (maintained) ecommended Torque 0.8 N m (7. in lb.) Applicable Wire Size Minimum x AWG, max. x AWG or x AWG ontact esistance Initial contact resistance of 50mΩ or less ontact Gap mm (N and N), mm (N-EM and N-B) Horsepower ating eference Value: / (ø non-reversing), (ø non-reversing) ontact Material Silver (gold plated contacts available - contact IDE) perating Temperature peration: 5 to 50 (without freezing), Storage: 0 to 70 (without freezing) Vibration esistance 0 to 55Hz, 98m/sec (0G) conforming to IE Shock esistance 980m/sec (00G) conforming to IE Mechanical ife Momentary pushbuttons: 5,000,000 (900 operations per hour), All other switches: 500,000 onforming to Standards EN6097-, EN , VDE , U508, SA - No. Approvals SA: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (00/0, 5, 0, 00/0, 0, 0, 80, 00/0, ) File No. E6896 File No. 97 U: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (00/0, 5, 0, 00/0, 0, 0, 80, 00/0, ) TÜV: pushbuttons and selector switches: A600=P600 (N, N)/Q600 (N-EM, N-B) ertificate No. pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (00/0, 5, 0, 00/0, 0, 0, 80, 00/0, ) egistration No (E-stops) egistration No (Dual Pushbuttons) egistration No. J96505 (Pilot ights) egistration No. J95558 (all other switches) Electric Shock Protection Degree of Protection (conforming to IE6059) (conforming to NEMA IS6-0) Pollution Degree (conforming to IE6097-) External Short-ircuit Protection eferencing Pushbuttons Illuminated Pushbuttons Selector Switches Illuminated Selector Switches Pushbutton Selectors lass 0 conforming to IE6056 IP65 (from front of the panel) IP0 (Type HW-F contact block) NEMA,,,, S,,, 5,, (from front of panel) for switches not using a transformer, for switches using a transformer 0A 50V fuse conforming to IE6069- onforming to ENEE EN50005 ontact Block Type HW-/HW-F /HW-G ated Insulation Voltage 600V ated ontinuous urrent 0A ontact atings by Utilization ategory IE A-5 (A600) D- (P600) perational Voltage V 8V 50V 0V 0V 0V A- ontrol of resistive loads & solid state loads 0A 0A 0A 6A A A 50/60 Hz perational A-5 ontrol of electromagnetic loads (> 7VA) 0A 7A 5A A A urrent D- ontrol of resistive loads & solid state loads 8A 5A.A.A D D- ontrol of electromagnets 5A A.A 0.6A For dimensions, see page
3 ømm - HW Series ED amp atings (STD Type) Model STD-6k STD-k STD-k STD-Hk STD-Mk amp Base BA9S/ ated Voltage 6V A/D V A/D V A/D A A Voltage ange 6V A/D ±0% V A/D ±0% V A/D ±0% A ±5% A ±5% A,, W: 7mA A urrent G, S: 8mA ma ma 0mA 0mA Draw A,, W: ma D G, S: 5.5mA 0mA 0mA olor ode A (amber), G (green), (red), S (blue), W (white) amp Base olor Same as illumination color Voltage Marking Die stamped on the base ife (reference value) Approx. 50,000 hours (The luminance reduces to 50% the initial intensity when used on complete D.) A,, W A,, W Internal ircuit G, S ED hip Protection Diode Zener Diode In place of k, specify the ens/ed olor ode. Signaling ights elays & Sockets Timers ontactors Blocks ircuit Breakers IDE () USA & anada 55
4 ømm - HW Series Illuminated Selector Switches -Position (Assembled) Signaling ights elays & Sockets Timers -Position Illuminated Selector Switches ontact perator Position Type Maintained Spring eturn from ight perator nly HWnF-k HWnF-k N- N N N- N Full Voltage HWnF-FQm-k-l HWnF-FQm-k-l HWnF-FHm-k HWnF-FMm-k HWnF-FT8m-k HWnF-FHm-k HWnF-FMm-k HWnF-FT8m-k Full Voltage HWnF-F0Qm-k-l HWnF-F0Qm-k-l HWnF-F0Hm-k HWnF-F0Mm-k HWnF-F0T8m-k HWnF-F0Hm-k HWnF-F0Mm-k HWnF-F0T8m-k Full Voltage HWnF-FQm-k-l HWnF-FQm-k-l HWnF-FHm-k HWnF-FMm-k HWnF-FT8m-k HWnF-FHm-k HWnF-FMm-k HWnF-FT8m-k ontactors Blocks ircuit Breakers. In place of k specify ens/ed color code.. In place of l specify Full Voltage code.. In place of m specify amp code.. In place of n enter for plastic bezel or for metal bezel. 5. For nameplates, see page For contact assembly part numbers, see page ight is independent of switch position. 8. All assembled part numbers in catalog include standard fingersafe (HW-F...) 9. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an F from the part number (Ex. HWB-MF- becomes HWB-M-). 0. Units with exposed screw terminals (HW-...) must be ordered as sub-components.. Yellow selector switch comes with white ED.. Additional contact configurations available (up to 6 total contacts).. For Truth Tables see page 608. k ens/ed olor ode olor ode Amber A Green G ed Blue S White W Yellow Y l Full Voltage ode Full Voltage Models Voltage ode 6VA/D 6V VA/D V VA/D V A (ED only) A (ED only) m amp ode amp ode Incandescent Blank ED D n ode Type ode Plastic Metal 580
5 ømm - HW Series : Plastic : Metal * Position : Maintained : Spring eturn from ight ontact Blocks Structure H W F F 0 Q D G V ontact Arrangement : N-N Illumination ircuit 0: N Q: Full Voltage : N-N H: A M: A T8: Tranformer A ead Holder * not needed with full voltage models. amp ircuit omponents Description s ead Holder Dummy Block with Unit (6V secondary voltage) HW-B on all illuminated pushbutton units. ne required for each deck (pair) of odd number of even number of A A A ens olor A: Amber S: Blue G: Green W: White : ed Y: Yellow amp ode D: ED Blank: Incandescent Illuminated Selector Switches -Position (eplacement Parts) Adaptor Part Number HW-H HW-DAFB HW-DAB HW-GA TW-DAFB TW-DAB TW-F6B TW-F6B TW-F86B HW-T6 HW-T6 HW-86 TW-T6B TW-T6B TW-T86B D-D onverter 0VD HW-6D. HW-GA Dummy Block with full voltage adaptor does not require the use of HW-H.. D-D convertor features spring-up terminals.. D-D convertor applicable voltage range 90-0V D. perators Plastic Description Metal Maintained HWF- HWF- Spring return from right HWF- Illuminated knobs must be ordered separately. HWF- Safety ever ock amp Anti-otation ing ontact Blocks ontacts N N Standard (IP0) Spring-Up Screw ontact Block Adaptor HW-B. Used to mount contact blocks to operator (first pair only).. IDE strongly recommends using the safety lever lock to prevent heavy vibration or maintenance personnel from inadvertently unlocking Safety ever ock HW9Z-S Illuminated Knob Appearance HW9Z-FDY-k In place of k, specify the olor ode. amp Voltage (Full voltage units only) 6V: 6V A/D V: V A/D V: V A/D : A* : A* *ED only perator ens = ompleted Unit HW-F0 HW-F0 (early make) HW-G0 HW-G0 (early make) HW-0 HW-0 (early make) HW-F0 HW-F0 (late break) HW-G0 HW-G0 (late break) HW-0 HW-0 (late break) k ens/ed olor ode olor ode olor ode Amber A Blue S Green G White W ed Yellow Y Anti-otation ing HW9Z- Use with notched panel cutout to prevent unit rotation. amps Voltage 6V A/D STD-6k ED V A/D STD-k V A/D STD-k A STD-Hk A STD-Mk Incandescent 6V A/D V A/D V A/D IS-6 IS- IS-. In place of k, specify the ED olor ode.. The ED contains a current-limiting resistor and reverse polarity protection diodes.. Use white ED for yellow lens. Yellow ED not available. Signaling ights elays & Sockets Timers ontactors Blocks ircuit Breakers IDE () USA & anada 58
6 ømm - HW Series Illuminated Selector Switches -Position (Assembled) ircuit Breakers Blocks ontactors Timers elays & Sockets Signaling ights -Position Illuminated Selector Switches ontact perator Position Type Maintained Spring eturn from ight Spring eturn from eft Spring eturn Two- Way perator nly HWnF-k HWnF-k HWnF-k HWnF-k N- N N N N- N N N 0 0 Full Voltage HWnF-FQm-k-l HWnF-FQm-k-l HWnF-FQm-k-l HWnF-FQm-k-l HWnF-FHm-k HWnF-FMm-k HWnF-FT8m-k HWnF-FHm-k HWnF-FMm-k HWnF-FT8m-k HWnF-FHm-k HWnF-FMm-k HWnF-FT8m-k HWnF-FHm-k HWnF-FMm-k HWnF-FT8m-k Full Voltage HWnF-F0Qm-k-l HWnF-F0Qm-k-l HWnF-F0Qm-k-l HWnF-F0Qm-k-l HWnF-F0Hm-k HWnF-F0Mm-k HWnF-F0T8m-k HWnF-F0Hm-k HWnF-F0Mm-k HWnF-F0T8m-k HWnF-F0Hm-k HWnF-F0Mm-k HWnF-F0T8m-k HWnF-F0Hm-k HWnF-F0Mm-k HWnF-F0T8m-k Full Voltage HWnF-F0Qm-k-l HWnF-F0Qm-k-l HWnF-F0Qm-k-l HWnF-F0Qm-k-l HWnF-F0Hm-k HWnF-F0Mm-k HWnF-F0T8m-k HWnF-F0Hm-k HWnF-F0Mm-k HWnF-F0T8m-k HWnF-F0Hm-k HWnF-F0Mm-k HWnF-F0T8m-k HWnF-F0Hm-k HWnF-F0Mm-k HWnF-F0T8m-k Full Voltage HWnF-FQm-k-l HWnF-FQm-k-l HWnF-FQm-k-l HWnF-FQm-k-l HWnF-FHm-k HWnF-FMm-k HWnF-FT8m-k HWnF-FHm-k HWnF-FMm-k HWnF-FT8m-k HWnF-FHm-k HWnF-FMm-k HWnF-FT8m-k HWnF-FHm-k HWnF-FMm-k HWnF-FT8m-k Full Voltage HWnF-F0Qm-k-l HWnF-F0Qm-k-l HWnF-F0Qm-k-l HWnF-F0Qm-k-l HWnF-F0Hm-k HWnF-F0Mm-k HWnF-F0T8m-k HWnF-F0Hm-k HWnF-F0Mm-k HWnF-F0T8m-k HWnF-F0Hm-k HWnF-F0Mm-k HWnF-F0T8m-k HWnF-F0Hm-k HWnF-F0Mm-k HWnF-F0T8m-k Full Voltage HWnF-F0Qm-k-l HWnF-F0Qm-k-l HWnF-F0Qm-k-l HWnF-F0Qm-k-l. In place of k specify ens/ed color code.. In place of l specify Full Voltage code.. In place of m specify amp code.. In place of n enter for plastic bezel or for metal bezel. 5. For nameplates, see page For contact assembly part numbers, see page ight is independent of switch position. 8. All assembled part numbers in catalog include standard fingersafe (HW-F...) HWnF-F0Hm-k HWnF-F0Mm-k HWnF-F0T8m-k 9. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an F from the part number (Ex. HWB-MF- becomes HWB-M-). 0. Units with exposed screw terminals (HW-...) must be ordered as subcomponents.. Yellow selector switch comes with white ED.. Additional contact configurations available (up to 6 total contacts).. For Truth Tables see page 608. HWnF-F0Hm-k HWnF-F0Mm-k HWnF-F0T8m-k k ens/ed olor olor ode Amber A Green G ed Blue S White W Yellow Y HWnF-F0Hm-k HWnF-F0Mm-k HWnF-F0T8m-k l Full Voltage ode Full Voltage Models Voltage ode 6VA/D 6V VA/D V VA/D V A (ED only) A (ED only) HWnF-F0Hm-k HWnF-F0Mm-k HWnF-F0T8m-k m amp ode amp ode Incandescent Blank ED D n ode Type ode Plastic Metal 58
7 ømm - HW Series : Plastic : Metal * Position : Maintained ontact Arrangement : Spring eturn from ight : Spring eturn from eft : Spring eturn -Way : N-N 0: N 0: N : N-N 0: N 0: N ontact Blocks ead Holder * not needed with full voltage models. amp ircuit omponents Description s ead Holder Dummy Block with Unit (6V secondary voltage) HW-B on all illuminated pushbutton units. ne required for each deck (pair) of odd number of even number of A A A Structure H W F F 0 Q D G V Illumination ircuit Q: Full Voltage H: A M: A T8: Tranformer A ens olor A: Amber S: Blue G: Green W: White : ed Y: Yellow amp ode D: ED Blank: Incandescent Illuminated Selector Switches -Position (eplacement Parts) Adaptor Part Number HW-H HW-DAFB HW-DAB HW-GA TW-DAFB TW-DAB TW-F6B TW-F6B TW-F86B HW-T6 HW-T6 HW-86 TW-T6B TW-T6B TW-T86B D-D onverter 0VD HW-6D. HW-GA Dummy Block with full voltage adaptor does not require the use of HW-H.. D-D convertor features spring-up terminals.. D-D convertor applicable voltage range 90-0V D. perators Description Plastic Metal Maintained HWF- HWF- Spring return from right HWF- HWF- Spring return from left HWF- HWF- -Way spring return HWF- HWF- Illuminated knobs must be ordered separately. Safety ever ock amp Anti-otation ing ontact Blocks ontacts N N Standard (IP0) Spring-Up Screw ontact Block Adaptor HW-B. Used to mount contact blocks to operator (first pair only).. IDE strongly recommends using the safety lever lock to prevent heavy vibration or maintenance personnel from inadvertently unlocking Safety ever ock HW9Z-S Illuminated Knob Appearance HW9Z-FDY-k In place of k, specify the olor ode. Full Voltage ode 6V: 6V A/D V: V A/D V: V A/D : A* : A* *ED only perator ens = ompleted Unit HW-F0 HW-F0 (early make) HW-G0 HW-G0 (early make) HW-0 HW-0 (early make) HW-F0 HW-F0 (late break) HW-G0 HW-G0 (late break) HW-0 HW-0 (late break) k ens/ed olor ode olor ode olor ode Amber A Blue S Green G White W ed Yellow Y Anti-otation ing HW9Z- Use with notched panel cutout to prevent unit rotation. amps Voltage 6V A/D STD-6k ED V A/D STD-k V A/D STD-k A STD-Hk A STD-Mk Incandescent 6V A/D V A/D V A/D IS-6 IS- IS-. In place of k, specify the ED olor ode.. The ED contains a current-limiting resistor and reverse polarity protection diodes.. Use white ED for yellow lens. Yellow ED not available. Signaling ights elays & Sockets Timers ontactors Blocks ircuit Breakers IDE () USA & anada 58
Switches & Pilot Devices
ø16mm - B Series Style Standard Bezel (black) Operation ontact Material Non-Illuminated Pushbuttons (Assembled) ontact Standard Bezel P Board Flush Bezel P Board olor ode k SPDT BjB-M1T5k BjB-M1T1Vk BlmB-M1T5k
More informationSwitches & Pilot Devices
ømm - TW Series features: TW NEMA Switches with snap-on contacts Corrosion resistant octagonal chrome plated locking bezel Snap-on 0A contact blocks Incandescent or LED illumination Slow make, double break,
More informationSwitches & Pilot Devices
features: TW NEMA Switches with snap-on contacts Corrosion resistant octagonal chrome plated locking bezel Snap-on 0A contact blocks Incandescent or LED illumination Slow make, double break, self cleaning
More informationPUSHBUTTON SWITCH / SELECTOR SWITCH / ILLUMINATED PUSHBUTTON SWITCH PSA, LPSA TYPE
PUSHBUTTON SWITCH / SEECTOR SWITCH / IUMINATED PUSHBUTTON SWITCH PSA, PSA TYPE FEATURES 1 3 The PSA and SPSA types are oil-proof. The enclosure rating is IP65 (water-jet-proof type), covering wide applications.
More informationComplete units: Push-buttons ø 22mm
Complete units: Push-buttons ø 22mm FLUSH SPRING RETURN - NON-ILLUMINATED Chrome Bezel Part Number Technical Info (p. 103) Black Bezel Part Number 11 Ø 29.9 20.1 19.6 With single position clip Red NC L21AA01-1E01
More informationComplete units: Selector switches ø 22mm
Complete units: Selector switches ø 22mm SELECTOR SWITCHES - NON-ILLUMINATED Technical Info (p. 13) WITH KNOB 2 and 3 positions Chrome Bezel Part Number Black Bezel Part Number Ø 29.9 Maintained positions
More informationComplete units: Mushroom heads ø 22mm
Complete units: Mushroom heads ø 22mm MAINTAINED - NON-ILLUMINATED Ø 40 MUSHROOM Push-pull to reset Technical Info (p. 103) Black Bezel Part Number 34.2 Ø 40 Red NC L22DD01-3E01 Red 2 NC L22DD01-3E02 Red
More informationSection. Display Lights. Selection Guides... C 2. SignaLight Towers... C 4
ourtesy of Steven Engineering, Inc. 230 Ryan Way, South San rancisco, A, 94080-6370 Main Office: (650) 588-9200 Outside Local Area: (800) 258-9200 www.steveneng.com Section Selection Guides... 2 SignaLight
More informationControl Stations ø 22
Control Stations ø 22 CONTROL STATIONS - NON-ILLUMINATED Technical Info (p. 103) MUSHROOM HEAD Ø 40 - MAINTAINED Push-turn to reset Part Number M16/20 47.9 25.7 Ø 40 Red NC EMERGENCY STOP LBX10510 Red
More informationDisplay Lights. Display Lights. LT1 Series. LT1 Series SignaLight Light Towers. Display Lights with a Tower of Advantages
LT1 Series SignaLight Light Towers with a Tower of Advantages Key features of the LT1 series SignaLight towers include: ustom configurations meet your specifications simply Select your flash preference,
More informationOperator Heads: ø 22mm
Operator Heads: ø 22mm SPRING RETURN - NON-ILLUMINATED Technical Info (p. 103) FLUSH-FLUSH Twin touch Chrome Bezel Part Number Black Bezel Part Number 12.3 11 53.9 29.9 With International Symbols Green
More informationOperator Heads: ø 22mm
Operator Heads: ø 22mm ONE-PIECE PILOT LIGHTS Technical Info (p. 103) SUPPLIED WITHOUT BULB Part Number L20SA40 14.3 44.1 Ø 29.8 Ø 20.2 Ø 22 Ø 29.5 1 to 6 6 Ribbed Lens Clear Smooth Lens With text or symbol
More informationTWTD Series: Heavy duty switches built to last
ø0mm - TWTD Series iltight TWTD Series Full Size NEMA Pushbuttons TWTD Series: Heavy duty switches built to last features include: Variety of button sizes up to 9/6" (65mm) Rugged construction includes
More informationTimers RTE. RTE Series Analog Timers
RTE RTE Key features: 20 time ranges and 10 timing functions Time delays up to 600 hours Space-saving package High repeat accuracy of ± 0.2% ON and timing OUT LE indicators Standard 8- or 11-pin and 11-blade
More informationAccessories. Accessories
Series 61 16mm 22.5mm 21 x 21mm 21 x 27mm IP65 5 250V INDITOR PUSHUTTON E-STOP KEYLOK SELETOR hoose one component from each of the coloured sections to assemble a complete switch. For other options or
More informationM = Maintained S = Spring Return. Operator Only ➊ No Contacts M M 800T-00HX2KB6 M M 800T-24HR2KB6AX 800T-24HR17KB6AX Incandescent
ulletin 800T 30.5 mm Push uttons 2-Position Knob/Lever Type Selector Switch Units, Illuminated Operator Position Operator Type Standard Knob Knob Lever Type Lamp Volts olor M = Maintained S = Spring Return
More informationSeparate units: Blocks
Separate units: Blocks LED BLOCKS Technical Info (p. 103) SCREW TERMINALS Part Number 3.8 LED 19.7 20.1 X1 X2 33EARL 9.9 19.7 21.5 18.2 12/24 V White Red Green Blue Yellow 33EAWL 33EARL 33EAGL 33EABL 33EAYL
More informationTimers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range 13.
G3 G3 Key features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions and output status indicating LEs Specifications
More informationSEALED, ILLUMINATED ROCKER SWITCHES
K/K LOW OST, ROKER FOR WET & DUSTY ENVIRONMENTS The K series rockers are rugged, high performance sealed switches designed for use under severe conditions found in marine, appliance, heavy equipment and
More informationPendant control stations 6
Characteristics 6 Environment Conformity to standards IEC 97-5-1, EN 6097-5-1 Product certifications NEMKO. Special version: UL Listed A600-Q600, CSA A600-Q600 Protective treatment Standard version TH
More informationSection. Display Lights Selection Guides... C 2. SignaLight Towers 70mm LT7 Modular Series... C 4 56mm LT1 Series...
Section New Selection Guides... 2 SignaLight Towers 70mm LT7 Modular Series...... 4 56mm LT1 Series.............. 7 Panel Mounting Annunciators SL30 Series, 1.18" (30mm)... 14 SL30-IPS Series 1.18" (30mm)
More informationApplication Description
- N Mechanically Held February ontents Description Page Product Description...... - Application Description... - Features................ - Operation.............. - Instructional Leaflets..... - Standards
More informationControl stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M
Characteristics Pendant control stations, for control circuits Environment Conforming to standards IEC 947-5-1, EN 60947-5-1 XAC-B : standard version : NEMKO, CSA 300 V type 4 Approvals XAC-M : standard
More informationand signalling units Ø 22 1 Harmony XB7 Monolithic pushbuttons, switches and pilot lights
Characteristics 1 Environment Protective treatment Standard version TH Ambient air temperature Storage C - 40 + 70 around the device Operation C - 25 + 70 for LED and neon bulb versions - 25 + 40 for incandescent
More information800T T2 H2 E E X X. a b c d e f g Right Left Right Left. d, e, f, g. c (cont'd) 1-, 2-, 3-, 4-Way Toggle Switches (Bul. 800T only)
1-,, 3-, 4- Toggle Switches (Bul. 800T only) 800T T2 H2 E E X X a b c d e f g Right Left Right Left Blank C T1 T2 T3 T4 a Finger-Safe Guards Description No guards Guards on terminals b Operator Type Description
More informationMK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure
General-purpose Relays MK-S (New Models) CSM_MK-S_DS_E 1 New Super MK Relays. Latching Lever Added to the Series. Same mounting and internal wiring as the previous Super MK Relays Built-in mechanical indicator
More informationRelays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:
RU Series Universal Relays Key features: Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator
More informationBulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.
Bulletin H Product verview/specifications Bulletin H/ Hazardous locations push buttons and stations Classes I, II & III Divisions & / in. - NPSM barrel Type & Explosion-proof operators Table of Contents
More informationRelays & Sockets. RH Series Compact Power Relays. Part Number Selection. Blade Terminal
RH Key features SPDT through PDT, 0A contacts Compact power type relays Miniature power relays with a large capacity 0A contact capacity Compact size saves space Contact SPDT PDT PDT RH Series Compact
More informationGeneral Specifications
General Specifications Electrical apacity (Resistive Load) Power Level: 6A @ 25V A & 3A @ 250V A or 6A @ 30V Other Ratings ontact Resistance: Insulation Resistance: ielectric Strength: Mechanical Life:
More informationTwo-way Action Test Button (Models with Lockable Test Button) For Momentary Operation
General Purpose Relays MKS Exceptionally Reliable General Purpose Relay now available with Lockable Test Button IEC Rating of A 0 V AC 0/0 Hz, General use 100,000 cycles. Mechanical indicator standard
More informationLR Position Switches TECHNICAL DATASHEET
TECHNICA DATASHEET Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 69 contact blocks available actuators available M assembled connector versions Silver
More informationRelays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection
RY/RM Series Miniature Relays Key features: RY (A), RY (A), RM (A) General purpose miniature relays A or A contact capacity Wide variety of terminal styles and coil voltages meet a wide range of applications
More informationFor more information, please visit or call toll free at
GT3 GT3 Key features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions and output status indicating LEs UL,
More information60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay
Series - General purpose relays - 0 A Features Plug-in mount 0 A General purpose relay.. & pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listed (certain relay/socket
More informationCatalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009
Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred
More informationModel Number Structure
General-purpose Relay MK-I/-S Electromechanical Relays Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks relatively large load currents despite small size. Long
More informationOMRON MK-I / -S RELAY
Issued April 0 0 DATA SHEET OMRON MK-I / -S RELAY Based on OMRON Datasheet General-purpose Relay MK-I/-S 0 Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks
More informationGeneral Specifications
eries W lides Rotaries Programmable Illuminated P Pushbuttons upplement Accessories Indicators General pecifications Electrical apacity (Resistive Load) Power Level: 9A @ 125V A or 6A @ 250V A Other Ratings
More informationFM series position switches
FM series position switches Selection diagram 0 08 0 A A 0 A 0 External rubber gasket External rubber gasket External rubber gasket External rubber gasket 0 69 Round rod, stainless steel Square rod Glass
More informationRelays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.
RFV Key features: Compact and EN compliant RFV force guided relays Force guided contact mechanism (EN00 Type A TÜV approved) Contact configuration -pole (NO-NC, 3NO-NC) 6-pole (NO-NC, NO-NC, 3NO-3NC) Built-in
More information150 C 30 F B D 8L 152H C 30 F BD 43 8L
ulletin SM - Smart Motor ontrollers atalog Number Explanation Open and Non-ombination F D L a b c d e f g a ulletin Number Solid-State ontroller b ontroller Type SM- c mpere s N F d Enclosure Type Open
More information22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection
Relays 22 Technical Data...1 Specifications...2 Model Number Structure - Relays...3 Model Number Selection... 4-5 Electrical Characteristics...6 Accessories...7 Dimensions...8 Instructions...10 Safety
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More informationA W - A 2A R - 24D - 1
Knob-type Selector Switch A165S/W Mounting Aperture of 16 mm Modular construction Oil-resistant IP65 models UL and cul approved. Conforms to EN60947-5-1, IEC947-5-1 Short mounting depth, less than 28.5
More informationPower supply CP-E 24/0.75
2CDC 271 016 F0t06 a OUTPUT L+, L : terminals output b INPUT L, N, PE: terminals input c LOW: red LED output voltage too low d OK: green LED output voltage OK e OUTPUT Adjust: rotary potentiometer output
More informationPower supply CP-D 24/4.2 Primary switch mode power supply
Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution
More informationGeneral-purpose Relay
General-purpose Relay Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks relatively large load currents despite small size. Long life (minimum 0,000 electrical
More informationRound Indicator Lights Mounting Hole Page
PRODUCT SERIES Round Indicator Lights Page 8, &. 9. &..7 - NEMA -R.7 8 & 9. 7. 8. 9 7. 8. - NEMA -R.9.9 Indicator Lights.7,.. 7. Rectangular Indicator Lights Panel Cutout. x.. x. 7 & 7. x.8 8. x. 9 & 7.
More informationSolid-state Timer H3DS
Solid-state Timer H3DS DIN Track Mounted, Standard 17.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock. (24 to 230 VAC/VDC
More informationRU Series Universal Relays
Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal
More informationPower supply CP-D 24/1.3
2CDC 271 027 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 24 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 1.3 A Rated output power
More informationMK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure
General-purpose Relays MK-S (New Models) CSM_MK-S_DS_E New Super MK Relays. Latching Lever Added to the Series. Same mounting and internal wiring as the previous Super MK Relays Built-in mechanical indicator
More informationActuators Series 8602/3
> Large selection of actuators Pushbuttons Mushroom pushbuttons Rotary actuators Key-operated switches Mushroom stay-put buttons with key lock Mushroom stay-put buttons Twin pushbuttons Illuminated pushbuttons
More informationComponents for safety applications Preventa safety modules
Selection guide Applications Modules For Emergency Stop and limit switch monitoring (modules integrated in Micro PLCs) Conforming to standards Machine IEC 204-, EN 292, EN 48 assemblies EN 60204- Principles
More informationRJ Series Slim Power Relays
RJ Series RJ Series Slim Relays Circuit Breakers Terminal Blocks Timers Display Lights Switches & Pilot Lights Compact and rugged power relays. Large switching capacity. Compact housing only.7-mm wide.
More informationPower supply CP-E 48/5.0 Primary switch mode power supply Data sheet
2CDC 271 028 F0008 OUTPUT L+, L+, L-, L-: terminals - output Features Rated output voltage 48 V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output current 5 A Rated
More informationC-Series. Circuit Breaker.
-Series ircuit Breaker The -Series hydraulic/magnetic circuit breakers are ideal for applications that require higher amperage and voltage handling capability in a smaller package. They are available in
More informationPower supply CP-E 24/2.5
2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment
More informationPower supply CP-E 12/10.0 Primary switch mode power supply Data sheet
2CDC 271 024 F0008 OUTPUT L+, L+, L-, L-: terminals - output INPUT L, N, PE: terminals - input OUTPUT OK: green LED - output voltage OK OUTPUT LOW: red LED - output voltage too low OUTPUT Adjust: potentiometer
More information62 Series - Power relays 16 A. Features / /
6 Series - Power relays 6 A Features 6. / 6.3 6.-0300 / 6.3-0300 Printed circuit mount 6 A Power relay & 3 Pole changeover contacts or NO ( 3 mm contact gap) AC coils & DC coils Reinforced insulation between
More informationV2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC
P AC/DC voltage monitoring Multifunction Supply voltage 24 V DC or 230V AC/DC Supply circuit = Measuring circuit 1 change-over contact Width 22,5 mm Control elements Tripping delay Maximum threshold Minimum
More informationTimers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range
GT3A Key features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions and output status indicating LEDs UL,
More informationGeneral-purpose Relay
General-purpose Relay Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks relatively large load currents despite small size. Long life (minimum 0,000 electrical
More informationHMI Components. Series. Raised design PCB (with adaptor) Machinery and Automation. Indicator Illuminated pushbutton
Edition 10/2016 HMI Components 41 Series Characteristics The rectangular design of the Series 41 (18 x 24 mm) makes it especially suited: Raised design PCB (with adaptor) Functions The Series 41 incorporates
More informationModel Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models
Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model
More informationC 1. SPECTRONIC SP - Air circuit breakers. Summary. C.3 General characteristics. C.4 Fixed circuit breaker. C.5 Withdrawable circuit breakers
SPETRONI SP - Air circuit breakers Summary.3 General characteristics.4 Fixed circuit breaker.5 Withdrawable circuit breakers.6 haracteristics.7 RMS 7: protection and control unit.10 RMS 9: protection and
More informationHMI Components. Series. Flush design Raised design PCB (with adaptor) Indicator Pushbutton Illuminated pushbutton
Edition /204 HMI Components 8 Series Characteristics The compact 8 mm Series 8 is especially suited for: Flush design Raised design PCB (with adaptor) Functions The Series 8 incorporates the following
More informationSafety switches with slotted hole lever
Safety switches with slotted hole lever Selection diagram C1 C C C4 C5 Straight slotted hole lever Slotted hole lever at the left Slotted hole lever at the right (without bend) Slotted hole lever at the
More informationPendant control stations 6
Characteristics Pendant control stations For control circuits Environment Conformity to standards EN/IEC 0--, CSA C- n Product certiþ cations XAC B Standard version: CSA 00 V type XAC M Standard version:
More informationPendant control stations 6
Characteristics 6 For control circuits Environment Conformity to standards EN/IEC 6097-5-1, CSA C22-2 n Product certifications XAC B Standard version: CSA 300 V type XAC M Standard version: CSA 300 V type
More informationV2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...
P AC/DC current monitoring Multifunction Supply voltage 24-240V DC or 110-240V AC 1 change-over contact Width 22,5 mm Control element Tripping delay Maximum threshold Minimum threshold Function selector
More informationTable of Contents. 22mm Push Buttons. 30mm Metal Push Buttons. 22mm Plastic Enclosures, Control Boxes & Installation Instructions 30-35
Altech Corporation Since 1984, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff
More informationGeneral data. 13/20 Siemens IC Overview Front plate mounting
General data Overview Front plate mounting D C B E A F D NSD0_00029b B C A A B C D E F Actuator Front plate Holder Contact block Lampholder Support element For actuators see page /25 to /62. For contact
More informationCharacteristics 5 TeSys k contactors and reversing contactors
90 Characteristics contactors k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 424 Product certifications LCp and LPp K06 to
More informationTeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X
Characteristics Contactor type LC1 D09 D18 DT20 and DT25 Environment Rated insulation voltage (Ui) Conforming to IEC 097--1, overvoltage category III, degree of pollution: 3 Conforming to UL, CSA V 00
More informationPosition switches FM series
B Position switches FM series Selection diagram 0 08 0 A A 0 A 0 external rubber gasket external rubber gasket external rubber gasket external rubber gasket 69 stainless steel round rod square rod fiber
More informationAHU. Specifications. Materials. Ordering Information E UL Approved Illuminated Pushbutton. page 1
Specifications RoHS Compliant E222871 AHU Electrical Ratings Sealing Degree Electrical Life Mechanical Life Contact Resistance 3A @ 125VAC, 65 C, 50K cycles 3A @ 250VAC, 65 C, 50K cycles IP65 50,000 cycles
More information3.4. Control Relays and Timers. Contents Description D5RR/D5RF Series... D7PR/D7PF Series. General Purpose Plug-In Relays
.4 D7 Series Relay Contents Description D1RR/D1RF Series......................... D2RR/D2RF Series......................... DRR/DRF Series......................... D4 Series................................
More informationPower supply CP-D 12/2.1
2CDC 271 025 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 12 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 2.1 A Rated output power
More informationType Nominal voltage (V) Code HSV V
Speed control Speed control relay - mm Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - -wire PNP or NPN, Namur, voltage 0-0V or volt-free contact type Works
More informationLiquid level monitors and controls
Liquid level monitors and controls ontent M-ENE, M-ENE MAX... / 8 M-ENS... / 83 M-ENS UP/DOWN... / 84 M-ENN... / 85 M-ENN UP/DOWN... / 86 Accessories for liquid level relays... / 87 Technical data M-ENE,
More informationPower supply CP-E 24/2.5
2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment
More informationHigh-Speed DC Circuit-Breakers for Fixed Installation Type UR26, UR36, UR40 & UR46
O M P O N E N T S High-Speed D ircuit-reakers for Fixed Installation Type UR26, UR36, UR40 & UR46 The UR26, UR36, UR40 & UR46 are D high-speed current limiting air ircuit-reakers, trip free, single pole,
More informationReduced Voltage Starters
Reduced Voltage Starters ontrolled starting for low in-rush and smooth operation Sprecher + Schuh reduced voltage starters are designed for starting squirrel cage induction motors where the starting current
More informationReduced Voltage Starters
Reduced Voltage Starters ontrolled starting for low in-rush and smooth operation Sprecher + Schuh reduced voltage starters are designed for starting squirrel cage induction motors where the starting current
More informationRelays & Sockets. RF2V 2-Pole Force Guided Relays/SJ Series Relay Sockets. UL/Recogntion File No. E55996 TÜV SÜD. EU Low Voltage Directive
RFV RFV -Pole Force Guided Relays/SJ Series Relay Sockets Key features: -pole force guided relay to reduce cost and installation space. Force guided contact mechanism (EN00 Type A TÜV approved). Reinforced
More informationSwitches & Pilot Devices
ø0mm - Series Key features: Wide variety of heavy-duty oiltight cam switches Operators available up to positions Switches made with a double circuit contact block Contact blocks rated 00V, 0A Ideal for
More information58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4
58 58 3 & 4 CO relay interface modules, 31 mm wide with Push-in terminals Ideal interface for PLC and electronic systems 58.P3 58.P4 Type 58.P3 3 CO 10 A Push-in terminals Type 58.P4 4 CO 7 A Push-in terminals
More informationIDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)
IDEC RJ22 Series Slim Relays (Bifurcated Contacts) Phone: 00.94.042 - Fax:.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com RJ Series Slim Relay Plug-in Terminal (Bifurcated Contacts) High contact
More informationRF1V Force Guided Relays / SF1V Relay Sockets
FV Force Guided elays / SFV elay Sockets ompact and EN compliant FV force guided relays. Force guided contact mechanism (EN00 Type A TÜV approved) ontact configuration -pole (NO-N, NO-N) -pole (NO-N, NO-N,
More informationLC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition
Product datasheet Characteristics Main Range Product name Product or component type Device short name Contactor application Utilisation category Device presentation Poles description Pole contact composition
More informationDistributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. FEATURES AND SPEIFIATIONS Features and Benefits Board-mounting pegs provide
More informationPOWER PRODUCT Low Voltage Motor Starters Contents
POWER PRODUT Low Voltage otor Starters ontents - Full Voltage Non-Reversing NEA X Non-etallic - Full Voltage etallic -8 Non - ombination -9 ircuit Breaker ombination - Fusible Switch ombination and Non-Fusible
More informationSpecifications. Environmental. Operating Temperature [C (F)] for TRIAC output ( ) for all others
Specifications Environmental Line Line Green Line Analog ertifications UL Listed, SA Approved, and E Marked for all applicable directives Features S Wide selection for increased application flexibility
More informationComponents for safety applications
Metal, turret head, types CS-A, CS-C and CS-E Double insulated, turret head, types CS-PA, CS-TA and CS-TE Presentation Metal, types CS-A, CS-C, CS-E Switches with or without locking of the actuator Pages
More information40.4. Control Relays and Timers. Contents. D3PR/D3PF Series. General Purpose Plug-In Relays. Features. Standards and Certifications
Control Relays and Timers. D Series Relay Contents Description Page DPR/DPF Series................................ DPR/DPF Series................................ DPR/DPF Series Catalog Number Selection........................
More informationSolid-state Twin Timer
Solid-state Twin Timer -F Operates in flicker- or flicker- start mode with one Unit. Independent - and -time settings. Combinations of long - or -time and short - or -time setting are possible. Long time
More informationControl module CP-A CM
2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP A RU Threshold values adjustable (14 28 V) One relay output per monitored input / channel Approvals H UL 508, CAN/CSA C22.2 No.14 H UL 60950,
More informationGT3W Series Dual Time Range Timers. CSA Certified File No.LR58183 LR96764 LR83814
TW Series Courtesy of Steven Engineering, Inc. 0 Ryan Way, South San Francisco, CA, 00-70 Main Office: (50) 5-00 Outside Local Area: (00) 5-00 www.steveneng.com Specifications Time Range Rated Voltage
More information