Badger Meter Europa. Coriolis mass flow meters

Size: px
Start display at page:

Download "Badger Meter Europa. Coriolis mass flow meters"

Transcription

1 Badger Meter Europa Coriolis mass flow meters

2 2 Coriolis mass meters Coriolis mass meters are recommended for the direct, continuous measurement of the mass of flowing liquids independently of their conductivity, density, temperature, pressure and viscosity in the food, chemical and petrochemical industries. They are best suited to measure chemicals, liquid food, suspensions, molasses, inks, lacquers, pastes, etc. Measuring principle Coriolis mass flow metering is based on the physical principle that a force, the so-called Coriolis force, acts on a mass that is moving towards or away from the point of rotation within a rotating system. The symmetrical arranged measuring tubes 1 and 2 are vibrated against each other in the X and Y axis. The limbs RS 1 and RS 2 of the measuring tube 1 and the limbs RS 1 and RS 2 of the measuring tube 2 oscillate on a circular segment in case of zero flow. A M w v Cross section of pipe Mass Angular velocity Flow velocity Q Flow K c Coriolis force 1 and 2 Measuring tubes RS 1, RS 2 Limbs K c w x y RS 1 w 1 2 RS 2 w K c Q Q v = A

3 3 Coriolis RCT1000 mass flow meters Hazardous location transmitter The Badger Meter RCT1000 Coriolis mass flow meter identifies flow rate by directly measuring fluid mass over a wide range of temperatures with a high degree of accuracy. For fluids consisting of two liquids or a liquid with suspended solids, the RCT1000 Coriolis system can derive the concentration and mass Specifications of each fluid based on the density measurement. Furthermore, the unobstructed, open flow design makes it suitable for a variety of fluids such as slurries and other viscous, nonconductive fluids that are difficult to measure with other technologies. Simultaneous measurement of: Mass flow Density Temperature Pipe size mm (1/16 3 ) Accuracy Zero stability Repeatability Liquids: up to± 0.1% of flow rate up to± 0.025% of full scale up to± 0.05% of flow rate Process temperature range C ( F) Wetted material Application 316L stainless steel General area or hazardous location Density: up to± g/cm 3 Advantages: Unobstructed open flow design Low-maintenance operation with no free-moving parts ModBus RTU, ModBus TCP/ IP, HART, EtherNet I/P network options Advanced fluid diagnostic tools Batching and PID control Advanced software

4 4 Applications Unlike many flow measurement technologies, Coriolis mass flow meters can directly and accurately measure the mass flow of fluids over a wide range of fluid temperatures and viscosities. The Coriolis design and measurement principle allows the meter to be an exceptional device in measuring: Vegetable oils and fats Homogeneous suspensions and slurries Adhesive, glue or binding materials Coatings and hardeners Dyes, fragrances, vitamins and other additives Oil and fuels Chemical Pet food Textiles Combustion control Asphalt Engine test stands

5 5 Operating principle Coriolis flow meters simultaneously measure mass flow rate, density and temperature. As fluid flows through the vibrating sensor tube, forces induced by the flow cause the tube to twist slightly. These small deflections are measured by carefully placed sensors. A phase shift occurs between sensor signals that is directly proportional to mass flow rate. As the fluid density varies, the resonant frequency at which the tube vibrates changes which is also measured by the sensors. Temperature is measured by an internal RTD in order to calculate thermal effects on the tube vibrating frequency. Types of measurement Mass flow rate Density Temperature Derived from the phase shift between inlet and outlet sensing coils Derived from vibration frequency Measured and used to correct for changes in the stiffness of the vibrating tubes Internal operation (U-Tube design) Inlet Outlet Sensing coils U-Tubes Drive coil Phase shift NO FLOW Bottom view FLOW Bottom view Δ T = 0 Δ T > 0 Density frequency HIGH DENSITY LOW DENSITY RCT1000 Coriolis mass flow meters operate at low frequencies which reduce the formation of air slugs in liquids with entrained air. This operation keeps liquids more homogeneous and provides less erratic readings.

6 6 Controls & system integration RCT1000 transmitters provide a variety of ways to integrate the meter output into new and existing operations. The batch and PID functionality enables direct control of devices, such as valves, by use of digital or analog outputs. Digital outputs can also be programmed to indicate low and high alarm conditions. Network options EtherNet/IP ModBus TCP/IP ModBus RTU HART Signal outputs Frequency Pulse PWM 4 20 ma (qty 3) Quick configuration Easy-to-read LCD screen Remote or integral mounting PID loop control example Slurries are used in many products, but the proper mix needs to be controlled. As a slurry is pumped through the Badger Meter Coriolis flow meter, the meter measures the percentage of concentrate. Based on this measurement, the PID controller output from the RCT1000 transmitter will modulate the water addition to the mixer to ensure the exact concentration is achieved. In conjunction to the PID control function, the RCT1000 transmitter can also supply analog output or network connectivity for continuous monitoring of the percentage of solids as well as flow rate information to the control room. Research Control valve Coarse powder Water line 4-20 ma (current #1) Slurry controlled to % solids Feed Mixer % Solid (density) PID control RCS series sensor 4-20 ma (current #2) Mass flow output to control room RCT1000 transmitter

7 7 RCT user software Data logging Trending HealthTrack system verification Trend graphing Every RCT1000 Coriolis mass flow meter comes with RCT user software. The software is specifically designed to provide users maximum operational flexibility and ease-of-use. By allowing users quick access to configure measurement parameters through the RCT user software or the LCD interface on the transmitter, the meter can be set up and measuring flow in a matter of minutes. Data logging RCT user software offers much more than configuration features. Users are able to obtain advanced data logging and performance trending analysis, as well as system verification provided by the unique HealthTrack feature. HealthTrack system verification Remote display

8 Product line overview Electromagnetic flow meters Ultrasonic flow meters Weirs and flumes Turbine meters Oscillating piston meters Nutating disc meters Impeller meters Vortex meters Variable area flow meters Differential pressure flow meters Venturi tubes Mass meters Heat meters Hydraulic testers Flow calibrators Lubrication meters Oil management systems Control valves Concrete finishing products Badger Meter Europa For Switzerland Badger Meter Swiss AG Mittelholzerstr Bern Switzerland Tel Fax info@badgermeter.ch For the United Arab Emirates Badger Meter Europe Middle East Branch Office Dubai Silicon Oasis Head Quarter Building Wing C, Office #C209 Dubai / UAE Tel Fax gramaswamy@badgermeter.com Badger Meter Europa GmbH Nürtinger Str Neuffen Germany Tel Fax badger@badgermeter.de For the USA and Canada Badger Meter, Inc. P.O. Box Milwaukee, WI USA Tel Fax infocentral@badgermeter.com For Mexico Badger Meter de las Americas S. A. de C. V. Pedro Luis Ogazon #32 Col. Guadalupe Inn Mexico, D. F Mexico Tel Fax bmdla@badgermeter.com For Asia Badger Meter Europa GmbH Singapore Branch 80 Marine Parade Road #21 06 Parkway Parade Singapore Singapore Tel Fax awang@badgermeter.com For China Badger Meter, Inc. Shanghai Representative Office Hangzhong Road Minhang District Shanghai China Tel Fax rjiang@badgermeter.com For Slovakia and the Czech Republic Badger Meter Slovakia s. r. o. Racianska 109 / B Bratislava Slovakia Tel Fax badgermeter@badgermeter.sk For Poland, Ukraine, Belarus and the Baltic countries Badger Meter Europe Eastern Europe Branch Office ul. Korfantego Knurów / Poland Tel biuro@badgermeter.com COR_RCT1000_UB_02_1703 Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change products specifications without prior notice.

Coriolis Mass Flow Meters. Advanced flow measurement made easy.

Coriolis Mass Flow Meters. Advanced flow measurement made easy. Coriolis Mass Advanced flow measurement made easy. Introducing Coriolis Mass The Badger Meter RCT1000 Coriolis mass flow meter identifies flow rate by directly measuring fluid mass over a wide range of

More information

Signal Conditioner. Intelligent Frequency Converter. User Manual. SGN-UM EN-03 (July 2015)

Signal Conditioner. Intelligent Frequency Converter. User Manual. SGN-UM EN-03 (July 2015) Signal Conditioner Intelligent Frequency Converter SGN-UM-00283-EN-03 () User Manual Signal Conditioner, Intelligent Frequency Converter CONTENTS Scope of This Manual 3 Unpacking and Inspection 3 Safety

More information

Signal Conditioner. Intelligent Frequency Converter. User Manual. SGN-UM EN-01 (November 2013)

Signal Conditioner. Intelligent Frequency Converter. User Manual. SGN-UM EN-01 (November 2013) Signal Conditioner Intelligent Frequency Converter SGN-UM-00283-EN-01 (November 2013) User Manual Signal Conditioner, Intelligent Frequency Converter Page ii November 2013 User Manual CONTENTS INTRODUCTION

More information

K-Factor Scalers. Models B , B , B and B B B B B User Manual. SGN-UM EN-05 (June 2017)

K-Factor Scalers. Models B , B , B and B B B B B User Manual. SGN-UM EN-05 (June 2017) K-Factor Scalers Models B-, B-, B- and B- B- B- B- B- SGN-UM--EN- (June ) User Manual K-Factor Scalers, Models B-, B-, B- and B- Page ii June User Manual CONTENTS Scope of This Manual Unpacking and Inspection

More information

Industrial Oval Gear. Meters and Registers. User Manual. IOG-UM EN-08 (October 2014)

Industrial Oval Gear. Meters and Registers. User Manual. IOG-UM EN-08 (October 2014) Industrial Oval Gear Meters and Registers IOG-UM-00046-EN-08 () User Manual Industrial Oval Gear, Meters and Registers Page ii IOG-UM-00046-EN-08 User Manual CONTENTS Scope of this Manual 5 Product Unpacking

More information

Proven Measurement for A World of Applications

Proven Measurement for A World of Applications Proven Measurement for A World of Applications Building on Experience. Niagara Meters is a flow meter company representing a complete line of flow meters manufactured by Venture Measurement Co., LLC in

More information

Ambient Conditions. Operating Conditions. Pressure

Ambient Conditions. Operating Conditions. Pressure Temperature Relative Humidity -20 C +75 C 0% 100 RH to 65 C non condensing 86 106 bar 4.0MPa (DN10 DN80) 1.6MPa (DN100 DN150) 1.0MPa (DN200 DN1000) Remote version < 80 C (rubber coating) Compact version

More information

FH CMF Coriolis Mass Flow Meters

FH CMF Coriolis Mass Flow Meters FH CMF Coriolis Mass Flow Meters 1. Introduction Coriolis Mass Flow Meters patented and developed by our company (Chinese Patent No. 03119685.3, 03149996.1) are the leading meters for precision flow measurement.

More information

Process Control Calibration Made Easy with Agilent U1401A

Process Control Calibration Made Easy with Agilent U1401A Process Control Calibration Made Easy with Agilent U1401A Application Note This application note explains how the Agilent U1401A with simultaneous source and measure functions eases technicians calibration

More information

CoriolisMaster Measurement made easy Accurate flow measurement of liquids and gases

CoriolisMaster Measurement made easy Accurate flow measurement of liquids and gases Measurement & Analytics Measurement made easy CoriolisMaster Measurement made easy Accurate flow measurement of liquids and gases Measurement made easy Highest measurement accuracy, easy installation and

More information

WATERFLUX 3000 Quick Start

WATERFLUX 3000 Quick Start WATERFLUX 3000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000

More information

ADDMAS CORIOLIS MASS FLOW METER

ADDMAS CORIOLIS MASS FLOW METER ADDMAS CORIOLIS MASS FLOW METER 1. General ADDMAS Series Coriolis Mass Flow meter (here after we call CMF ) is designed according to the coriolis principle. It can be widely used for the process detecting

More information

WATERFLUX 3000 Quick Start

WATERFLUX 3000 Quick Start WATERFLUX 3000 Quick Start Electromagnetic flowmeter The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000

More information

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications OPTISONIC 3400 Ultrasonic flowmeter for liquids in all industrial applications Measurement of conductive and non-conductive, low and high viscous liquids, from -200 to +250 C / -328 to +482 F medium temperature

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

OPTIMASS 1000 Technical Datasheet

OPTIMASS 1000 Technical Datasheet OPTIMASS 1000 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:

More information

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically

More information

The World's Most Versatile Range of. Coriolis Flowmeters

The World's Most Versatile Range of. Coriolis Flowmeters The World's Most Versatile Range of Coriolis Flowmeters 1. Adhesives No moving parts to be plugged or fouled. Bitumen Rheonik meters operate at continuous high temperature while providing high accuracy

More information

The World's Most Versatile Range of. Coriolis Flowmeters

The World's Most Versatile Range of. Coriolis Flowmeters The World's Most Versatile Range of Coriolis Flowmeters 1. Adhesives No moving parts to be plugged or fouled. Bitumen Rheonik meters operate at continuous high temperature while providing high accuracy

More information

Field Devices and Wiring

Field Devices and Wiring Field Devices and Wiring Slide 2-1 Field Device and Wiring Overview The control system interfaces to the process through field devices. Our ability to control a process is limited to the accuracy of measurement

More information

The World's Most Versatile Range of. Coriolis Flowmeters

The World's Most Versatile Range of. Coriolis Flowmeters The World's Most Versatile Range of Coriolis Flowmeters 1. Adhesives No moving parts to be plugged or fouled 8. Bitumen Rheonik meters operate at continuous high temperature while providing high accuracy

More information

Ultrasonic Level Transmitter.

Ultrasonic Level Transmitter. Ultrasonic Level Transmitter www.fine-tek.com INTRODUCTION The ultrasonic level transmitter is a non-contact, low-cost and easy-to-install measuring device. It can be applied to most industrial applications

More information

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER 1 www. otech.com.sg EFS801 - CFT181/RFT201 ELECTROMAGNETIC FLOWMETER Accurate, Reliable and Stable Flow Measurement. Measuring Principle The measuring

More information

The World's Most Versatile Range of. Coriolis Flowmeters

The World's Most Versatile Range of. Coriolis Flowmeters The World's Most Versatile Range of Coriolis Flowmeters 1. Adhesives No moving parts to be plugged or fouled. Bitumen Rheonik meters operate at continuous high temperature while providing high accuracy

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits RHE11 Hazardous Area Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mount Built in safety barriers allow operation with RHM sensor in hazardous area Selectable Metric and English

More information

Liquid & Gas Flowmetering

Liquid & Gas Flowmetering Course Title Liquid & Gas Flowmetering COURSE OVERVIEW IE250 Liquid & Gas Flowmetering Course Date/Venue Session 1: October 25-29, 2015/Shahama Meeting Room, Crowne Plaza Hotel, Abu Dhabi, UAE Session

More information

BATCHFLUX 5500 C Technical Datasheet

BATCHFLUX 5500 C Technical Datasheet BATCHFLUX 5500 C Technical Datasheet Electromagnetic flowmeter for volumetric filling machines High-stability ceramic measuring tube, therefore extremely long-term stability Optimum hygienic design Only

More information

TIDALFLUX 2300 F Technical Datasheet

TIDALFLUX 2300 F Technical Datasheet Technical Datasheet Electromagnetic flow sensor for partially filled pipes Measurement in partially filled pipes up to DN1600 / 64" Patented, non-contact level measurement Measurement possible down to

More information

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual SWITCH 600 Series Velocity Flow Sensor Instruction Manual Ultrasonic Velocity Sensor using Doppler Technology Model: FS-600 Manual Release Date: November, 2009 ECHO Process Instrumentation, Inc. CONTENTS

More information

F-SERIES FOR. Indicators Totalizers Transmitters Flow computers Batch controllers Monitors. Flow Level Pressure Temperature

F-SERIES FOR. Indicators Totalizers Transmitters Flow computers Batch controllers Monitors. Flow Level Pressure Temperature F-SERIES Indicators Totalizers Transmitters Flow computers Batch controllers Monitors Flow Level Pressure Temperature FOR F - SERIES F - SERIES F - SERIES F - SERIES F - SERIES F - SERIES F - SERIES F

More information

MEASUREMENT, TRANSMITTERS AND FILTERING

MEASUREMENT, TRANSMITTERS AND FILTERING MEASUREMENT DEVICE CHE302 LECTURE II MEASUREMENT, TRANSMITTERS AND ILTERING Professor Dae Ryook Yang all 2001 Dept. of Chemical and Biological Engineering Korea University CHE302ProcessDynamicsandControl

More information

Rotamass TI Coriolis Mass flow meter

Rotamass TI Coriolis Mass flow meter General Specifications Rotamass TI Coriolis Mass flow meter Rotamass Prime Scope of application Precise flow rate measurement of fluids and gases, multi-phase media and media with specific gas content

More information

Advancements in Clamp-on Ultrasonic Flow Measurements Biosolids Workshop December 1 st 2016

Advancements in Clamp-on Ultrasonic Flow Measurements Biosolids Workshop December 1 st 2016 Advancements in Clamp-on Ultrasonic Flow Measurements 2016 Biosolids Workshop December 1 st 2016 Market Leader in Clamp-On Ultrasonic Flowmeters with >50,000 instruments sold Background Information Extraordinary

More information

RISONIC modular Ultrasonic transit time flow measurement in penstocks and open channels

RISONIC modular Ultrasonic transit time flow measurement in penstocks and open channels RISONIC modular Ultrasonic transit time flow measurement in penstocks and open channels FLOW CONTROL PENSTOCK MONITORING WATER BALANCE TURBINE/PUMP EFFICIENCY MEASUREMENT Power station Irrigation LAN Applications

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:

More information

The Discussion of this exercise covers the following points: Introduction How a tuning fork works Industrial applications. How a tuning fork works

The Discussion of this exercise covers the following points: Introduction How a tuning fork works Industrial applications. How a tuning fork works Exercise 3 Vibrating Level Switch EXERCISE OBJECTIVE Learn the working principle of vibrating level switches and learn how to use the vibrating level switch, Model 46933. DISCUSSION OUTLINE The Discussion

More information

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved. Flow Technologies Overview Mag Flow MAGFLO Program Siemens offers a comprehensive selection of electromagnetic flow meters Water & waste water Chemical Food & beverage Mining Aggregates Cement Pharmaceutical

More information

OPTIFLUX 1000 Technical Datasheet

OPTIFLUX 1000 Technical Datasheet OPTIFLUX 1000 Technical Datasheet Electromagnetic flow sensor in sandwich design Lightweight and compact Excellent price performance ratio Quick and easy to install The documentation is only complete when

More information

General Specifications

General Specifications General Specifications ROTAMASS Total Insight Coriolis Mass Flow and Density Meter GS 01U10B04-00EN-R Scope of application Advantages and benefits Precise flow rate measurement of fluids and gases, multi-phase

More information

Inclinometer Selection Guide

Inclinometer Selection Guide POSITION AND MOTION SENSORS Inclinometer Selection Guide Page No. 1 GLOBAL PRESENCE FRABA Group Sales Partner America FRABA Inc. Hamilton, NJ, USA Asia FRABA Pte. Ltd. Singapore Europe POSITAL GmbH Cologne,

More information

Rotamass TI Coriolis Mass flow meter

Rotamass TI Coriolis Mass flow meter General Specifications Rotamass TI Coriolis Mass flow meter Rotamass Supreme Scope of application Precise flow rate measurement of fluids and gases, multi-phase media and media with specific gas content

More information

TMU. Coriolis Mass Flow Meter. for liquids and gas

TMU. Coriolis Mass Flow Meter. for liquids and gas Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to

More information

ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Intense

ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Intense General Specifications ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Intense Scope of application Advantages and benefits Precise flow rate measurement of fluids and gases, multi-phase media

More information

NGR. Guided Wave Radar Level Transmitter

NGR. Guided Wave Radar Level Transmitter Guided Wave Radar Level Transmitter measuring monitoring analyzing NGR For Liquids Operates Independent of Density, Temperature, Pressure, Humidity, and Conductivity Standard Measuring Length: 6. Ft (Longer

More information

DigitalFlow XMT868i. Panametrics Liquid Flow Ultrasonic Transmitter. GE Measurement & Control. Applications. Features

DigitalFlow XMT868i. Panametrics Liquid Flow Ultrasonic Transmitter. GE Measurement & Control. Applications. Features GE Measurement & Control DigitalFlow XMT868i Panametrics Liquid Flow Ultrasonic Transmitter The DigitalFlow XMT868i liquid flow transmitter is a complete ultrasonic flow metering system for measurement

More information

Level Sensors Reed Contact Chain

Level Sensors Reed Contact Chain Level Sensors Reed Contact Chain measuring monitoring analysing Measuring length: Measuring accuracy: 0.5% for L = 2000 mm Pressure: max. 20 bar Temperature: max. 130 C Connection: G 3 8 to G 2 flange:

More information

ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Supreme

ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Supreme General Specifications ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Scope of application Advantages and benefits Precise flow rate measurement of fluids and gases, multi-phase media and

More information

Optimize your Ultrasonic Flow Meter for Water & Wastewater Applications

Optimize your Ultrasonic Flow Meter for Water & Wastewater Applications Optimize your Ultrasonic Flow Meter for Water & Wastewater Applications Standards Certification Education & Training Publishing Conferences & Exhibits Speaker: Brent Baird, Instruments Direct 2013 ISA

More information

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22 Coriolis Massflowmeter for liquids and gas measuring monitoring analysing TMU S5 Measuring range: 0-60 kg/h 0-2200 t/h water Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040)

More information

SITRANS L Level instruments

SITRANS L Level instruments SITRANS L Level instruments /2 Point level measurement /6 Capacitance switches /9 Pointek CLS100 /1 Pointek CLS200 /31 Pointek CLS300 /47 Pointek CLS00 /62 Pointek Specials Electro-mechanical switches

More information

Magnetic Inductive Flowmeter

Magnetic Inductive Flowmeter Magnetic Inductive Flowmeter for conductivity liquids measuring monitoring analysing Measuring range: up to 10 m/s Accuracy: ±1.5% of reading ±0.5% full scale pmax: PN40 tmax: -40 +150 C Connection: flange

More information

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit High performance microflow Coriolis Flowmeter GENERAL SPECIFICATION GS.No. GENERAL Based on the Coriolis technologies accumulated over many years, the OVAL has broadened its current general purpose coriolis

More information

914DNS. Pressure and Density Transmitter. Features. 1 Datasheet 914DNS Pressure and density transmitter.

914DNS. Pressure and Density Transmitter. Features. 1  Datasheet 914DNS Pressure and density transmitter. Pressure and Density Transmitter Features Pressure and density transmitter. Low maintenance, quick calibration and configuration. Installation directly into pressurized vessels. HART technology provides

More information

TUR. Turbine Wheel Flowmeter. Plastic Model for Liquids. Measuring Ranges: GPM or GPM (Water)

TUR. Turbine Wheel Flowmeter. Plastic Model for Liquids. Measuring Ranges: GPM or GPM (Water) Turbine Wheel Flowmeter Plastic Model for Liquids measuring monitoring analyzing TUR TUR with Transmitter TUR with ADI-1 Measuring Ranges: 5.3...88 GPM or 11...440 GPM (Water) Measuring Accuracy: ± 1%

More information

LZYN Triangle Series Mass Flow Meter

LZYN Triangle Series Mass Flow Meter LZYN Triangle Series Mass Flow Meter 1. General LZYN Triangle Series Mass Flowmeter is designed according to the Coriolis Principle.It can be widely used for the process detecting and custody transfor/fiscal

More information

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI Overview Integration The flowmeter pulse output is often used as input for heat calculators. The range of meters enables optimum measurement of energy consumption. The analog output is used to inform the

More information

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9 Overview MAGFLO family MAGFLO electromagnetic are designed for measuring the flow of electrically conductive mediums. The patented MAGFLO Verificator guarantees accurate measurement and simple verification.

More information

Micro Motion Fork Viscosity Meters

Micro Motion Fork Viscosity Meters Product Data Sheet PS-001486, Rev B June 2014 Micro Motion Fork Viscosity Meters High performance multi-variable viscosity meter Rugged, accurate multi-variable measurement Continuous, multi-variable measurement

More information

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL MicroChem Water Analysis System The MicroChem is a versatile multi-parameter instrument capable of being configured as a transmitter or PID controller. Specifically designed for drinking and wastewater

More information

Self contained servo drive CLDP Technical data sheet

Self contained servo drive CLDP Technical data sheet voith.com Self contained servo drive CLDP Technical data sheet Advantages + + High energy efficiency + + High dynamics + + Oil free power pack and piping are not necessary + + Sensors used provide the

More information

Output performance: Analogue output accuracy check. Pulse output accuracy check.

Output performance: Analogue output accuracy check. Pulse output accuracy check. An insight into the reasons for verification: Confidence in ongoing performance, regulatory requirements, maintaining process quality. Calibration: The comparison of measurement values delivered by a device

More information

Instrumentation and Control Technician A Guide to Course Content Implementation Beginning with Level 1 April 2013

Instrumentation and Control Technician A Guide to Course Content Implementation Beginning with Level 1 April 2013 Instrumentation and Control Technician A Guide to Course Content Implementation Beginning with Level 1 April 2013 Instrumentation and Control Technicians maintain, diagnose, calibrate and repair measurement

More information

Coriolis Mass Flow Meter Model TM

Coriolis Mass Flow Meter Model TM Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :

More information

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

MIM. Electromagnetic Flowmeter. Compact, All-metal Design Electromagnetic Flowmeter Compact, All-metal Design measuring monitoring analyzing MIM For Measurement and Monitoring of Conductive Liquids Flow and Temperature Measurement Switching, Transmitting, and

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:

More information

MaxxFlow HTC Flow measurement for dry bulk solids

MaxxFlow HTC Flow measurement for dry bulk solids Product Information EN MaxxFlow HTC Flow measurement for dry bulk solids SWR engineering Messtechnik GmbH envea TM a trademark of Environnement S.A Group MaxxFlow HTC MaxxFlow HTC MaxxFlow HTC Use The

More information

Level Measurement With REFLEX RADAR

Level Measurement With REFLEX RADAR Reflex Radar & TDR HYC-RR02 Elect. Iss. 02 Level Measurement With REFLEX RADAR Why Radar Technology for Level Measurement? INSENSITIVE TO CHANGES IN Dielectric Pressure Vacuum Humidity Dust Viscosity Foam

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

Model S50-D Density Sensor Specifications

Model S50-D Density Sensor Specifications Issue/Rev. 0.1 (4/99) S-Mass Meter S50-D Density Specifications ulletin SS0M020 The S-Mass Density derives its name from the S-shaped tubes of the flow sensor. This patented geometry produces a high signal-to-noise

More information

4/111. Overview. Benefits Greater flexibility Wide product program Uniform sensor interface enabling "plug & play" for all transmitters

4/111. Overview. Benefits Greater flexibility Wide product program Uniform sensor interface enabling plug & play for all transmitters Siemens AG 2008 Overview coriolis mass flowmeters are designed for measurement of a variety of liquids and gases. The meter is a multi parameter device offering accurate measurement of mass flow, volume

More information

Micro Motion Filling Mass Transmitters with Modbus

Micro Motion Filling Mass Transmitters with Modbus Configuration and Use Manual MMI-20018283, Rev AC April 2013 Micro Motion Filling Mass Transmitters with Modbus Configuration and Use Manual Micro Motion customer service Email Worldwide: flow.support@emerson.com

More information

The SFC 1000PA P2DAAA can be mounted on a prover trailer, which can be moved from field to field to provide proving services.

The SFC 1000PA P2DAAA can be mounted on a prover trailer, which can be moved from field to field to provide proving services. The SFC 1000 P2DAAA is a dual meter run bidirectional flow computer with a built in Rosemount 205 Multivariable Transmitter (DP, P, and TEMP) for the measurement of liquid & Gas products. Using orifice

More information

General Specifications

General Specifications General Specifications ROTAMASS Total Insight Coriolis Mass Flow and Density Meter GS 01U10B02-00EN-R Scope of application Advantages and benefits Precise flow rate measurement of fluids and gases, multi-phase

More information

Proline Promass F 300, 500

Proline Promass F 300, 500 MANUAL Special Documentation Proline Promass F 3, 5 Low-Temperature Version for Cryogenic Media SD1966O/6/EN/2.17 Material Number: 71362224 Document function Proline Promass F 3, 5 1 Document function

More information

9/28/2010. Chapter , The McGraw-Hill Companies, Inc.

9/28/2010. Chapter , The McGraw-Hill Companies, Inc. Chapter 4 Sensors are are used to detect, and often to measure, the magnitude of something. They basically operate by converting mechanical, magnetic, thermal, optical, and chemical variations into electric

More information

ISO-9001:2015 certified PRODUCTS GUIDE. Aplus Finetek Sensor, Inc. More than just another level measurement company. Aplus Finetek Sensor, Inc.

ISO-9001:2015 certified PRODUCTS GUIDE. Aplus Finetek Sensor, Inc. More than just another level measurement company. Aplus Finetek Sensor, Inc. ISO-9001:2015 certified PRODUCTS GUIDE Aplus Finetek Sensor, Inc. More than just another level measurement company Aplus Finetek Sensor, Inc. More than just another level measurement company Aplus Finetek

More information

2-wire level transmitter

2-wire level transmitter Badger Meter Europa GmbH 2-wire level transmitter Model L2xx INSTALLATION AND OPERATION MANUAL July 2002 Version UF-L2xx-07/02-e Contents Contents Page 1. Installation 1 1.1 Mounting the instrument 1 1.2

More information

SLW-Tri Series Sanitary Hygienic Liquid Turbine Flow Meter

SLW-Tri Series Sanitary Hygienic Liquid Turbine Flow Meter SLW-Tri Series Sanitary Hygienic Liquid Turbine Flow Meter Overview SLW series Turbine Flow has its simple structure, light weight, high-accuracy, perfect repeatability, sensitivity, easy maintenance and

More information

Using the AcuDew Moisture Transmitter

Using the AcuDew Moisture Transmitter APPLICATION NOTE 2018_5-1 AcuDew Using the AcuDew Moisture Transmitter The AcuDew Transmitter is a two wire, 4-20 ma loop powered transmitter for continuous moisture measurement in process gases, glove

More information

B r e a k t h r o u g h F l o wmeter Technology. Ultrasonic Flowmeter Range

B r e a k t h r o u g h F l o wmeter Technology. Ultrasonic Flowmeter Range TM B r e a k t h r o u g h F l o wmeter Technology Ultrasonic Flowmeter Range IDEAL FOR: Drink dispensing Laboratory tests Cooling equipment Active flow alarms Semiconductor plant OEM applications Pilot

More information

MaxxFlow HTC. Product Information. Flow Measurement for Dry Bulk Solids

MaxxFlow HTC. Product Information. Flow Measurement for Dry Bulk Solids EN MaxxFlow HTC Product Information Flow Measurement for Dry Bulk Solids MaxxFlow HTC MaxxFlow HTC MaxxFlow HTC Product Information Use The MaxxFlow HTC is specially developed for the flow measurement

More information

Electromagnetic flowmeter in all metal design Model MIM

Electromagnetic flowmeter in all metal design Model MIM Electromagnetic Flowmeter all metal design measuring monitoring analysing MIM O O For measuring and monitoring of conductive liquids OAccuracy: O < ± (0.8% of reading + 0.5% of full scale) O O Flow and

More information

TME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C

TME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C Coriolis Massflowmeter for liquids and gases measuring monitoring analysing TME OMeasuring O range: 0-60 kg/h 0-60000 kg/h water O O Accuracy: ±0.15 of reading ± zero-point stability OO p max : PN40 t

More information

MPU 200 Series B. Ultrasonic Gas Flowmeter. Specifications. Features. Principle of Operation

MPU 200 Series B. Ultrasonic Gas Flowmeter. Specifications. Features. Principle of Operation Ultrasonic Gas Flowmeter MPU 200 Series B Specifications Issue/Rev. 0.4 (10/11) Bulletin SSKS004 The MPU 200 Series B Ultrasonic Gas Flow Meter is a single path ultrasonic meter with non-intrusive and

More information

Magnetic Inductive Flow Sensors induq. Series VMI

Magnetic Inductive Flow Sensors induq. Series VMI Magnetic Inductive Flow Sensors induq Series VMI Free Flow! Compact - cost-effective - robust! The induq from SIKA is a trio of extremly compact, low cost, magnetic inductive fl ow sensors. This new product

More information

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet High-efficiency Circulator Pump Rio-Eco N / Rio-Eco Z N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco N / Rio-Eco Z N All rights reserved. The contents provided herein must

More information

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement ULTRASONlC FlOWMETER SAMPLE BOOK TYPE:LRF-3300S Concentrating on Flow Measurement Introduction LRF-3300S is a wall-mount, clamp- on type ultrasonic flowmeter which use the transfer time technology. Clamp

More information

INDUSTRIAL VIBRATION SENSOR SELECTION MADE EASY

INDUSTRIAL VIBRATION SENSOR SELECTION MADE EASY SENSORS FOR RESEARCH & DEVELOPMENT WHITE PAPER #28 INDUSTRIAL VIBRATION SENSOR SELECTION MADE EASY NINE QUESTIONS TO SUCCESSFULLY IDENTIFY THE SOLUTION TO YOUR APPLICATION www.pcb.com info@pcb.com 800.828.8840

More information

RUNYI GROUP AJ FLOW TOTALIZER. Features

RUNYI GROUP AJ FLOW TOTALIZER. Features AJ FLOW TOTALIZER Features Suitable for flow (Heat) displaying, calculating and controlling of all kinds of liquids, single or mixed gases and vapor. Input multiple flow sensor signals (Such as VSF, Turbine,

More information

Micro Motion Model 1500 Transmitter with the Filling and Dosing Application

Micro Motion Model 1500 Transmitter with the Filling and Dosing Application Product Data Sheet PS-00571, Rev. C January 2008 Micro Motion Model 1500 Transmitter with the Filling and Dosing Application Micro Motion's Model 1500 transmitter with the filling and dosing application

More information

Rotordynamics Analysis Overview

Rotordynamics Analysis Overview Rotordynamics Analysis Overview Featuring Analysis Capability of RAPPID Prepared by Rotordynamics-Seal Research Website: www.rda.guru Email: rsr@rda.guru Rotordynamics Analysis, Rotordynamics Transfer

More information

S103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING

S103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING ELECTROMAGNETIC FLOW METERS The electromagnetic flow meter is used to measure the flow rate of conductive fluids and waste water. The measurement is independent of the density, viscosity, temperature and

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

Continuous Sensors Accuracy Resolution Repeatability Linearity Precision Range

Continuous Sensors Accuracy Resolution Repeatability Linearity Precision Range Continuous Sensors A sensor element measures a process variable: flow rate, temperature, pressure, level, ph, density, composition, etc. Much of the time, the measurement is inferred from a second variable:

More information

Advancements in Clamp-on Ultrasonic Flow Measurements. Ohio Section AWWA SE District Fall Meeting September 1 st 2017

Advancements in Clamp-on Ultrasonic Flow Measurements. Ohio Section AWWA SE District Fall Meeting September 1 st 2017 Advancements in Clamp-on Ultrasonic Flow Measurements Ohio Section AWWA SE District Fall Meeting September 1 st 2017 About Us - Providing Measurement instrumentation and data collection since 1984 - State

More information

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two

More information

Pressure Transducer Handbook

Pressure Transducer Handbook 123 Pressure Transducer Handbook Date: February 2004 TABLE OF CONTENTS SECTION 1 - Introduction 1.1 Introduction 1.2 Product Overview SECTION 2 - Kulite Sensing Technology 2.1 Pressure Transducers 2.2

More information

JTR Guided Wave Radar Level Transmitter.

JTR Guided Wave Radar Level Transmitter. JTR Guided Wave Radar Level Transmitter www.fine-tek.com PRODUCT INTRODUCTION OPERATING PRINCIPLE The guided wave radar level transmitter is a solid and liquid level measuring instrument commonly used

More information