MODULOBLOC TRANSFORMERS
|
|
- Georgia Fields
- 6 years ago
- Views:
Transcription
1 PRODUCT LEAFLET MODULOBLOC TRANSFORMERS Network Modulobloc Transformer (3200 V V V from 1 to 160 kva) /06/2014
2 PRODUCTS PRESENTATION SINGLE-PHASE SETS FOR SINGLE-PHASE NETWORKS A concentric two-pole cable or two single-pole cables Connection interface IDR BI Transformer TEE (1 to 6 kva) Transformer TED-E (8 to 10 kva) Transformer TED-E (16 to 50 kva) SINGLE-PHASE TRANSFORMERS FOR THREE-PHASE NETWORKS A three-pole cable or three single-pole cables Connection interface IDR TRI Transformer TEE (1 to 6 kva) Transformer TED-E (8 to 10 kva) Transformer TED-E (16 to 50 kva) THREE-PHASE TRANSFORMERS FOR THREE-PHASE NETWORKS A three-pole cable or three single-pole cables Connection interface IDR TRI Transformer TED-E (5 to 32 kva) Transformer TEH-E 2
3 NETWORK TRANSFORMERS Modulobloc Type 1 to 160 kva With independent connection interface CONTENTS Pages GENERAL PRESENTATION SINGLE PHASE NETWORKS :Modulo Bi Single phase transformers for single phase networks TEE transformer (1 to 6 kva)... 7 TED-E transformer (8 to 50 kva)... 8 Connection interface IDR Bi... 9 Single phase network accessories THREE PHASE NETWORKS : Modulo Tri Single phase transformers for three phase networks TEE transformer (1 to 6 kva) TED-E transformer (8 to 50 kva) Three phase transformers for a three phase network TED-E transformer (5 to 32 kva) TEH-E transformer (50 to 160 kva) Interface connection IDR Tri Three phase network equipment INTERLOCKING - MODULOBLOC PITS
4 ALL THE ADVANTAGES OF EPOXY RESIN For sets, transformers and connection interfaces : single-phase from 1 kva to 50 kva or three-phase from 5 kva to 160 kva The use of epoxy resin guarantees that the transformers have the following characteristics : Corrosion resistant, remain unaltered over time. Watertight and immersible. Insulated. Can be buried into purposedely-deisgned pits. MODULOBLOC MAIN CHARACTERISTICS Watertight and immersible sets Conform to NFC standards and CEI 76 Dielectric : Dry, epoxy, up to 6 kva Oil from 8 to 160 kva Primary insulation voltage : 7.2 kv Secondary insulation voltage : 1.1 kv Reduced losses Protection degree : IP 68 - IK 10 Working temperature : -15 C +40 C Impulse withstand : 45 kv wave shape 1 / 50 Withstand industrial frequency : 5.5 kv : 22 kv - 50 Hz - 1 minute : 3.2 kv : 16 kv - 50Hz - 1 minute Especially designed to support the no load lamp stress. Studied to allow network continuity in case of a transformer default. MV PLUG-INS ON THE SEPARATED CONNECTION INTERFACE : The MV plug-in terminal systems of the connection interface guarantees total operational flexibility : Easy to plug in and unplug. Optimum reliability : the watertight connections rarely come in contact with water. Regardless of type of cable used, a specially designed plug-in terminal answers all your requirements. Absence of voltage test, earthing and short circuiting checking compartments, in conformity with recommended NFC standards, accessible directly on the top of the interface. IDR Tri with a network input and output on the twisted three-pole cable and a transformer supply derivation. IDR Bi with a network input and output on the two pole cable, an output network on the twisted single pole cables and a transformer supply derivation. The transformers low voltage output is carried out with a 1.5 meter H 07 RNF cable. A LV plug-in terminal for the transformers with a power rating superior to 8 kva can be provided. 4
5 DOUBLE «AUTO» PROTECTED TRANSFORMERS : Protection devices directly incorporated in the transformer guarantee : MV protection with easily-accessible HRC fuses Thermal protection using a thermal probe on a 1.5 meter long cable Optional : Low voltage protection using thermal-magnetic circuit breaker or fuses installed in a separate cabinet allowing protection against short circuiting with the possibility of several feeders. Starting from 8 kva this protection can be integrated directly on the transformer. Stick fuse on the TEE 1 kva Stick fuse on the Three-phase TED-E 5 kva Two-pole circuit breaker in a low Voltage cabinet (CBT) ADVANTAGES OF MODULOBLOCS SERIES A complete range of equipment to carry out absence of voltage tests available on request, conforming to recommended NFC standards. Connection accessories routinely delivered with each transformer. Voltage adjustment tap changers of +-5% provided to transformers from 16kVA and to the three-phase transformers of all power ratings. Selection of phases carried out directly on IDR connection interface enables, using the single-phase transformer installed on three-phase networks, the charge on the three-phases of the network to be balanced. Modulo tri 10 kva The IDR connection interfaces are also used as deviation boxes. MV networks epoxy resin accessories are also available. They enable cable isolation to be carried out, among other things. On request, AUGIER technicians carry out on site technical assistance, in France start up of MV installation and guarantees technical training leading to full understanding of the technical features of the product and how it works. 5
6 MODULO BI RANGE Electrical modular equipment comprising the single-phase 3200 V network The range of MODULOBLOC products consists of TEE or TED-E transformers, IDR connection interfaces and annex equipment. EXAMPLES : IDR BI junction Two way junction allowing existing networks to conform to safety regulations and recommended NFC standards. IDR BI deviation MODULO BI system with TEE 5 kva single-phase transformer and IDR BI connection interface Three way junction bow allowing a two-phase concentric or twisted single-phase cable connection 6 to 25 mm² in cross section. All above sets have a checking compartment allowing absence of voltage text to be carried out as well as earthing and short circuiting (MALT / CC), conforming to NF-C and UTE standards and requirements. DESIGN CHARACTERISTICS -Functional separation in three parts guarantees optimal reliability and easy access to maintenance points: *The transformation and MV fuse protection part, installed at bottom of the pit, are immersible. There is no connection point and therefore it needs no maintenance. *The connection part installed in the upper part provides easy access to all circuit points, the phases or neu tral position is clearly visible. *Low voltage protection is optional. - Application of regulations in force guarantee safety of maintenance workers: *A specially-provided compartment is directly accessible for this, situated on top *The absence of voltage test is carried out directly on the network, without interface. *Earthing and short circuiting is carried out before any handling of the terminals. - Easy installation: *Easy- to- assemble and operate connections : only network ends need to be built. *Connection to the network is carried out by one- pole plugs. *Equipment standardisation: connection box has only one model, fewer transformers and low voltage cubicles. 6
7 SINGLE PHASE TEE TRANSFORMER (1 to 8 kva) SINGLE PHASE TEE TRANSFORMER FOR A SINGLE PHASE NETWORK The transformer is immersible IP68 modulobloc, in epoxy resin, dry type with the following characteristics : MV cords L = 1.5 ml with plug / IDR LV cable L = 1.5 m HO 7 RNF 2 x 6 mm² < 6 kva Coupling : Single-phase Primary voltage : 3200 V Secondary no load voltage : 237 V Insulation voltage : 7,2 kv Power rating : 1; 2; 3; 4; 5; 6 kva Power output rating* : 0,8 1,6; 2,4; 3,2; 4; 4,8 kva MV fuse terminal H Borne de terre M 10x20 Thermal probe cable HO 7 RNF 2 x 1.5 mm² The transformer also comprises : Medium voltage input by two 1.5 meter-long flexible cables equipped with a single pole plug made in the TEE 5kVA 3200 V / 230 V factory, connectable to the IDR BI terminal. Primary protection fuse. Low voltage output by a two-pole 1.5 meter cable. Thermal probe output on a 1.5 meter cable to allow overload protection activated by current tripping circuit breaker with current indication alarm. Two earth terminals connected to metal part inside as well as to a low voltage winding end. ** l L Technical characteristics : Power rating (kva) Power output rating (kva) 0,8 1,6 2,4 3,2 4 4,8 Iron losses (W) Copper losses (W) Short circuit impedance (%) 2,9 2,5 2,5 2,5 2,5 3 Voltage drop (%) cos 2,6 1,91 1,52 1,51 1,52 1,86 Voltage drop (%) cos 2,84 2,49 2,4 2,08 2,4 2,89 Magnetising current (%) 9 8, Height H (mm) Length L (mm) Width l (mm) Total weight (kg) Conditions of use : Environment class AD7 : can be totally or partially immersed in water temporarily. * Conforms to public lighting NFC standards ** Others available on request Conforms to NFC standards Protection degree IP 68 LOW VOLTAGE PROTECTION CUBICLE Low voltage cubicle CBT IP67 Waterproof polyester cubicle, containing protection equipment, removable plexiglass cover, with compression glands for incoming cables. Suivant le cas, ces équipements peuvent être : One HRC fuse. A single pole + neutral circuit breaker up to 6 kva and a two pole one for the 8 kva, linked to a thermal probe located at the center of thansformers windings. Two half-power circuit breakers, single pole + neutral. Equipped with a LV circuit breaker Size : L 140 x W 170 x H 95 mm 7
8 SINGLE PHASE TED-E TRANSFORMER from 8 to 50 kva SINGLE PHASE TRANSFORMER TED-E FOR A SINGLE PHASE NETWORK The transformer is immersible, in epoxy resin, oil type with the following characteristics : Coupling : Single phase Primary voltage : 3200 V Secondary no load voltage : 237 V Insulation voltage : 7,2 kv Power rating : 8, 10, 16, 25, 32, 50 kva Power output rating* : 6,4; 8; 12,8; 20; 25,6; 40 kva MV cords L = 1.5 ml with plug / IDR preapared 1 x 6 mm² + shield MV fuse terminal H LV cable L = 1.5 ml HO 7 RNF 2 x 10mm² 10 kva HO 7 RNF 2 x 25mm² 16 kva HO 7 RNF 2 x 35mm² 25 kva HO 7 RNF 2 x 50 mm² 32 kva HO 7 RNF 2 x 95mm² 50 kva L Earth terminal M 10 x 20 The transformer also comprises : Medium voltage input by two 1.5 meter long flexible cables TED-E 16 kva 3200 V / 230 V with integrated LV protection equipped with a single pole plug, made in the factory, connectable to the IDR BI terminal. Primary protection fuse. LV output by a two-pole 1.5 meter long cable. Optional : two-pole unpluggable terminal for H 07 RNF cable up to 2 x 25 mm². Thermal probe output on 1.5 meter-long cable allowing overload protection activated by current tripping circuit breaker with current indication alarm. Two earth terminals connected to metal part inside as well as to a low voltage winding end. ** l Technical characteristics : Power rating (kva) Power output rating (kva) 6,4 8 12, ,6 40 Iron losses (W) Copper losses (W) Short circuit impedance (%) 3 3 5, ,5 Voltage drop (%) cos 1,47 1,34 2,3 2,42 1,98 2 Voltage drop (%) cos 2,73 2,66 4,81 4,51 4,28 5,11 Magnetising current (%) ,1 2,3 Height H (mm) Length L (mm) Width l (mm) Total weight (kg) Tap changer for voltage adjustment : Adjustments by strips of voltage, from 16 kva, taps +-5%. Conditions of use : Environment class AD7 : can be totally or partially immersed in water temporarily. * Conforms to public lighting NFC standards ** Others available on request Conforms to NFC standards Protection degree IP 68 LOW VOLTAGE PROTECTION CUBICLE CBT Waterproof polyester cubicle, containing protection equipment, removable plexiglass cover, equipped with compression glands for incoming cables Depending on requirements, this equipment can have: Two HRC fuses A two pole circuit breaker up to 25 kva, activated by a thermal probe placed at centre of transformer s windings. Two half*-power two -pole circuit breakers. On request, it can include circuit breaker (up to 25kVA) or low voltage fuse directly on transformer lid. In this case, the low voltage cables are 6 metres long. Low voltage cubicle CBT Equipped with a LV circuit breaker Dimension : see with us 8
9 190 INTERFACE IDR BI : CONNECTION INTERFACE IDR BI Epoxy resin monobloc terminal, pluggable, waterproof, single pole, lockable, to be fixed on the pit s walls, with following characteristics: Insulation voltage: 7.2 kv Crossing current in operation 3200 V single phase: 100 A This terminal consists of eight, single pole plug-in inputs allowing equally the functions of the input line, output or deviation line, deviation towards TEE or TED-E transformers, absence of voltage test (VAT) as well as earthing and short circuiting. On request : : this VAT cabinet can be equipped with a devices used only to test absence of voltage and to carry out earthing and short-circuiting. Junction layout (1I / 1O) TEE layout (1I / 1O / 1TEE) 3 Ways layout (1I / 2O) Earth terminal 2. Single pole plugs 3. Disconnectable BBM plug to check for absence of voltage and to carry out earthing INTERFACE IDR BI EQUIPMENT : Single- pole plug assembly kit Allowing all types of two pole concentric or twisted cables to be used from 6 to 25 mm². The single pole plugs resin support is asymmetrical to guarantee positioning of the phase in relation to neutral position Male two -pole plug Manipulated with a safety rod equipped with CMB key, for absence of voltage test and carrying out earthing and short-circuiting. There are two models available: For earthing of neutral (diagram TNRC) For isolating neutral (diagram TNRS) Male two pole plug BBM-C for TNRC network Male two pole plug BBM-I for TNRS networks Single pole plug 9
10 ANNEX EQUIPEMENTS SPECIFIC MAINTENANCE TOOLS: The operation key CMB for a two- pole plug allow extraction of male plugs and placing of earthing plate, with the help of a safety manipulating rod. Operation key CMB The earthing and short circuiting plate PMCB, manipulated with a safety rod, must be used only after extraction of the male two pole plug. Earthing and short circuiting plate PMCB EQUIPMENT TO INSULATE THE UNPLUGGABLE BBM male two pole plug can be used to insulate any one of the four IDR inputs. Three pole plug BBM-I (For TNRS network) BBF female two pole plug can be used to insulate two single pole plugs, thus leaving an isolated network. Female two plug BBF (*) EQUIPMENT TO EARTHING, IF NEEDED, PLUGGABLE PARTS: Earthing and short circuiting plate, PMCB, can earth any one of the four two -pole IDR inputs. Earthing and short circuiting plug allows the earthing of two single- pole plugs. Earthing and short circuiting plate PMCB Earthing and short circuiting plug EMCB (*) (*) These parts have a square base enabling IDR wall fixation support. 10
11 MAINTENANCE ACCESSORIES Maintenance operations for all MODULOBLOC systems must conform to NF C standards using the following accessories. Maintenance procedure is fully described in AUGIER S brochure «Maintenance of Modulobloc 5500 V networks». The safety manipulating rod is used for all operations and is telescopic. The electric voltage detector with sound signal is delivered in a special protection box supplied with extensions and batteries. The earthing clamp is attached to one part to the earthing strap, and another to the nearby earth circuit. The 1.5 metre-long earthing strap allows attachment of eathing and short-circuiting plate to the earth circuit. 11
12 MODULOBLOC TRI RANGE Electrical modular equipment comprising the 5500 V three-phase networks The range of MODULOBLOC products consist of TEE ou TED-E transformers, IDR tri connection interfaces and annex equipment. EXAMPLES : Three-way three-phase deviation MODULO tri system with 5 kva single phase transformer. Two -way three -phase junction allowing existing networks to conform to safety regulations. Three -way derivation with two 5 kva transformers. All above sets have a checking compartment for absence of voltage test (VAT) and carrying out earthing and short circuiting for safety protection (MALT/CC), conforming to NF-C and UTE standards and requirements. DESIGN CHARACTERISTICS -Functional separation in three parts guarantees optimal reliability and easy access to maintenance points: *Transformation and MV fuse protection part, installed at bottom of pit, are immersible. There is no connection point and therefore it needs no maintenance. *The connection part installed in the upper part provides easy access to all circuit points, the selection of phases or neutral is clearly visible. *Low voltage protection is optional. - Application of safety regulations in force guarantee maintenance work security: *A specially-provided compartment for this is easily accessible, situated on top *Checking for absence of voltage is carried out directly on the MV conductors. *Earthing and short circuiting is carried out before any handling of the terminals. - Easy installation: *Easy-to-assemble and easy to operate connections: only network ends need to be built. *Connection to the network is carried out by three- pole plugs. - Standardisation of equipment: connection box has only one model, fewer transformers and low voltage cubicles. 12
13 SINGLE-PHASE TEE TRANSFORMER (1 to 6 kva) SINGLE - PHASE TRANSFORMER TEE FOR A THREE -PHASE NETWORK The transformer is immersible epoxy resin monobloc, dry type with the following characteristics: Coupling : Single phase Primary voltage : 5500 V Secondary no load voltage : 237 V Insulation voltage : 7.2 kv Power rating : 1, 2, 3, 4, 5, 6 kva Power output rating* : 1.6; 2.4; 3.2; 4; 4.8 kva MV cords L = 1.5 ml with plug / IDR prepared 1x 6 mm² + shield MV fuse terminal H LV cable L=1,5 ml HO 7 RNF 2 x 6 mm² < 6kVA HO 7 RNF 2 x 10 mm² < 8 kva Earth terminal M 10 x 20 Thermal probe cable HO 7 RNF 2 x 1.5 mm² L = 1.5 ml This transformer also comprises: L Medium voltage input by two 1.5 metre-long flexible cables equipped with a single -pole plug,made in the TEE 5kVA 5500 V / 230 V factory, connectable to the IDR BI terminal. Two primary protection fuses. LV output by a two- pole 1.5 metre-long cable. Thermal probe output on a 1.5 metre-long cable for overload protection activated by a current tripping circuit breaker with current indicator alarm. Two earth terminals connected to metal part inside as well as to a low voltage winding end. ** l Technical characteristics : Power rating (kva) Power output rating (kva) 0,8 1,6 2,4 3,2 4 4,8 Iron losses (W) Copper losses (W) Short circuit impedance (%) 2,9 2,5 2,5 2,5 2,5 3 Voltage drop (%) cos 2,6 1,91 1,52 1,51 1,52 1,86 Voltage drop (%) cos 2,84 2,49 2,4 2,08 2,4 2,89 Magnetising current (%) 9 8, Height H (mm) Length L (mm) Width l (mm) Total weight (kg) Conditions of use: Environment class AD8: can be totally or partially immersed in water temporarily *Conforms to public lighting NFC standards ** Others available on request Conforms to the NFC standards Protection degree IP 68 LOW VOLTAGE PROTECTION CUBICLE CBT Waterproof polyester cubicle, containing protection equipment, removable plexigas cover, with compression glands for incoming cables. Depending on requirements, this equipment can have: Two HRC fuses A single pole + neutral circuit breaker, up to 6kVA activated by a thermal p r o b e p l a c e d a t c e n t r e o f t h e transformer s windings. Two half-power circuit breakers, single- pole plus neutral. Low voltage cubicle CBT IP 67 Equipped with one LV circuit breaker Dimensions : L 140 x H 170 x P 95 mm 13
14 SINGLE-PHASE TED-E TRANSFORMER (10 to 50 kva) SINGLE-PHASE TRANSFORMER TED-E FOR A THREE PHASE NETWORK The transformer is immersible epoxy resin, oil type with the following characteristics: Coupling : Single phase Primary voltage : 5500 V Secondary no load voltage : 237 V Insulation voltage : 7.2 kv Power rating : 8, 10, 16, 25, 32, 50 kva Power output rating* : 6.4; 8; 12.8; 20; 25.6; 40 kva MV cords L = 1.5 ml with plug / IDR prepared 1 x 6 mm² + shield MV fuse terminal H LV cable L=1.5 ml HO 7 RNF 2 x 10mm² 10 kva HO 7 RNF 2 x 25mm² 16 kva HO 7 RNF 2 x 35mm² 25 kva HO 7 RNF 2 x 95mm² 50 kva L Earth terminal M 10 x 20 This transformer also comprises: TED-E 16 kva 5500 V / 230 V with integrated LV Medium voltage input by two 1.5 metre-long flexible cables equipped with a single- pole plug,made in the factory, connectable to the IDR TRI terminal. Two primary protection fuses. LV output by a two- pole 1.5 metre cable. Optional: a two- pole unpluggable terminal for H.07.RN.F cable up to 2 x 25 mm². A thermal probe output on a 1.5 metre -long cable for overload protection activated by a current tripping circuit breaker with current indicator alarm. Two earth terminals connected to metal part inside as well as to a low voltage winding end. ** l Technical characteristics : Power rating (kva) Power output rating (kva) 6,4 8 12, ,6 40 Iron losses (W) Copper losses (W) Short circuit impedance (%) 3 3 5, ,5 Voltage drop (%) cos 1,47 1,34 2,38 2,42 1,98 2 Voltage drop (%) cos 2,73 2,66 4,81 4,51 4,28 5,19 Magnetising current (%) ,1 2,3 Height H (mm) Length L (mm) Width l (mm) Total weight (kg) Tap changer for voltage adjustment: Adjustment by moving straps of voltage, from 16 kva, taps +-5%. Conditions of use: Environment class AD7: can be totally or partially immersed in water temporarily. *Conforms to public lighting NFC standards ** Others available on request Conforms to NFC standards Protection degree IP 68 LOW VOLTAGE PROTECTION CUBICLE CBT Waterproof polyester cubicle, containing protection equipment, with removable plexiglas cover, equipped with compression glands for incoming cables. Low voltage cubicle CBT IP 67 Equipped with one LV circuit breaker Depending on requirements, this equipment can be with: Two HRC fuses A two -pole circuit breaker up to 25kVA, activated by a thermal probe placed at centre of transformer s windings. Two half-power two -pole circuit breakers. On request, it can include circuit breaker (up to 25kVA) or low voltage fuse directly on transformer lid. In this case, the low voltage cables are 6 meters long. Dimensions : see with us 14
15 THREE-PHASE TED-E TRANSFORMER (5 to 32 kva) THREE-PHASE TRANSFORMER TED-E FOR A THREE-PHASE NETWORK The transformer is immersible epoxy resin oil type with the following characteristics : Coupling : Three- phase Primary voltage : 5500 V Secondary no load voltage : 410V Insulation voltage : 7.2 kv Power rating : 5, 10, 16, 25, 32 kva Power output rating* : 4; 8; 12.8; 20; 25.6 kva MV Cords L=1.5 ml with plug/idr prepared 1 x 6 mm² + shield MV fuse terminal H LV cable L=1,5 ml HO 7 RNF 5 x 6mm² 5/10 kva HO 7 RNF 5 x 16mm² 16 kva HO 7 RNF 5 x 25mm² 25/32 kva Earth plug M 10 x 20 This transformer also comprises: L A medium voltage input using three 1.5 meter-long l flexible cables equipped with a single- pole plug, made in the factory, connectable to the IDR TRI terminal. TED-E 10 kva 5500 V / 400 V three phase transformer Three primary protection fuses. LV output by a five -pole 1.5 metre-long cable. Optional : A four- pole pluggable terminal for H.07.RN.F cables maximum diameter 44.5 mm. Thermal probe output on a 1.5 metre-long cable for overload protection activated by current tripping circuit breaker Two earth terminals connected to internal metal part as well as to a low voltage winding end. ** Technical characteristics : Power rating (kva) Power output rating (kva) , ,6 Iron losses (W) Copper losses (W) Short circuit impedance (%) 2,3 3,5 3,5 4 3,5 Voltage drop (%) cos 2,1 2,92 2,3 2,84 2,4 Voltage drop (%) cos 2,4 3,5 3,4 3,96 3,4 Magnetising current (%) 9 5, ,5 Height H (mm) Length L (mm) Width l (mm) Total weight (kg) Tap changer for voltage adjustment: Adjustment by moving straps of voltage, from 16 kva, taps +-5%. Conditions of use: Environment class AD7: can be totally or partially submerged in water on a temporary basis. *Conforms to public lighting standard NFC ** Others available on demande Conforms to the standard NFC Protection degree IP 68 LOW VOLTAGE PROTECTION CUBICLE CBT Waterproof polyester cubicle, containing the protection equipment, removable plexiglass cover, equipped with compression glands for incoming cables Low voltage cubicle CBT IP 67 Equipped with one LV circuit breaker Depending on requirements, this equipment can have: Three HRC fuses A four -pole circuit breaker up to 25 kva, activated by a thermal probe placed at centre of the transformer s windings. Two half-power four -pole circuit breakers. On request, it can include circuit breaker or low voltage fuse situated directly on transformer lid. In this case, the low voltage cables are 6 metres long. Dimensions : see with us 15
16 THREE-PHASE TEH-E TRANSFORMER (50 à 160 kva) THREE PHASE TEH-E TRANSFORMER FOR A THREE PHASE NETWORK Transformer is immersible epoxy resin, oil type, with the following characteristics: Coupling : Three phase Primary voltage : 5500 V Secondary no load voltage : 410V Insulation voltage : 7.2 kv Power rating : 50 ; 63 ; 80 ; 100 ; 125 ; 160 kva Power output rating* : 40 ; 50.4 ; 64 ; 80 ; 100 ; 128 kva Cordons 1 x 6 mm² + écran L=1,5 mètre avec fiche unipolaire confectionnée Anneau de levage H Câble BT L=6 ml HO 7 RNF 4 x 1 x 35mm² 50 à 80 kva HO 7 RNF 4 x 1 x 50mm² 100 kva HO 7 RNF 4 x 1 x 70mm² 125/160 kva Bornes fusibles HTI TEH-E 50 kva 5500 V / 400 V This transformer also comprises: Medium voltage input by three 1.5 metre long flexible cables, equipped with a single- pole plug, made in the factory, pluggable on the IDR TRI terminal. Three primary protection fuses. LV output in four single -pole 6 metre-long cables Thermal probe output on a 6 metre-long cable for overload protection activated by a current tripping circuit breaker with current indicator alarm Two earth terminals connected to internal metal part as well as to a low voltage winding end. ** L Technical characteristics : Power rating (kva) Power output rating (kva) 40 50, Iron losses (W) Copper losses (W) Short circuit impedance (%) 3,5 3,5 3, Coupling (%) cos Yzn11 Dyn11 Dyn11 Dyn11 Dyn11 Dyn11 Magnetising current (%) 2,8 2,6 2,6 2,4 2,2 2,1 Height H (mm) Length L (mm) Width l (mm) Total weight (kg) Tap changer for voltage adjustment: Adjustment by moving straps of voltage, from 16 kva, taps +-5% Conditions of use: Environment class AD7: can be totally or partially immersed in water temporarily. *Conforms to public lighting NFC standards ** Others available on request Conforms to NFC standards Protection degree IP 68 Oil weight (kg) Fiches unipolaires HTI Commutateur de réglage 16
17 367 CONNECTION INTERFACE IDR TRI INTERFACE IDR TRI Epoxy resin monobloc terminal, pluggable, waterproof IP68, three -pole, lockable, to be fixed to the pits walls, with the following characteristics: Insulation voltage: 7.2 kv Closing power rating in operation 5.5 kv three phase: 1000 kva This terminal consists of four, three -pole pluggable inputs allowing the following functions: Input line. Output or derivation line. Derivation towards a TEE or TED-E transformer Absence of voltage test as well as carrying out earthing and short circuiting. Conditions of use: For easy maintenance and even with the IDR having protection degree IP68, we recommend its use in an environment compatible with the AD7 class «can be totally or partially immersed in water temporarily». TEE layout 3 Ways layout Junction layout Earth terminal 3 - Single-pole deviation towards TEE 2 - Three-pole FTR plug 4 - Detachable BTM plug to test absence of voltage and carry out earthing INTERFACE IDR EQUIPMENT: Stainless steel wall fixation support Three -pole plug FTR assembly kit for use with all types of three- pole belt or twisted cable from 6 to 35 mm². Male three-pole plug Manipulated with a safety rod equipped with a CMB key for absence of voltage test, and carrying out earthing. Three-pole plug FTR Male three-pole plug BTM 17
18 SPECIFIC MAINTENANCE TOOLS: ANNEX EQUIPEMENTS The CMB operation key for three- pole plugs allows extraction of male three- pole plugs and placing of earthing plate, with the help of a safety manipulating rod. Operation key CMB The earthing and short circuiting plate, PMC, manipulated with a safety rod, must be used only after extraction of the male three- pole plug. Earthing and short circuiting plate PMC EQUIPMENT TO INSULATE THE UNPLUGGABLE PARTS: The BTM male three- pole plug can be used to insulate any one of the four three- pole IDR inputs. The BTF female three -pole plug can be used to insulate either a three- pole plug or no more than three single- pole plugs. Three- pole plug BTM Female three- pole plug BTF (*) EQUIPMENT FOR EARTHING, IF NEEDED, PLUGGABLE PARTS: The earthing and short circuiting plate, PMC, can earth any one of the four three- pole IDR inputs. The earthing and short circuiting plug allows the earthing of either three -pole plugs or no more than three single -pole plugs. Earthing and short circuiting plate PMC Earthing and short circuiting plug EMC (*) (*) These parts have a square base enabling IDR wall fixation support. 18
19 Accessories described on page 11. MAINTENANCE ACCESSORIES LOCKING SYSTEM PRINCIPLE Using an interlocking system access to the transformers and connection interface are dependant on the earthing and short circuiting of the cabling supplied at origin. This is carried out using an interlocking key together with a Ronis or Profalux key. MANHOLE LOCK The TED key can activate a safety lock to release the grid located inside the inspection manhole between access cover and transformer. Only specific pieces, corresponding to figures 5, 7 and 8, are listed in Augier rates. 1 - Fixation device 5 - Nylon cap 2 - Washer 6 - HM 10 screw 3 - Stainless steel nut 7 - Special nut 4 - Wire mesh 8 - Cap LOCKING TRANSFORMER TERMINALS AND CONNECTION INTERFACES If the manhole locking system cannot be used, a terminal locking system of fuse terminals can be installed directly on the transformer and MV terminals on the connection interface. The operating principle is the same as for the manhole lock, using a locknut. Nylon cap, Cap, Special nut. IDR locking by nut TEE locking by nut TEE locking detail MODULOBLOC CONCRETE PIT DIMENSIONS For MODULOBLOC BI and TRI Power rating Dimensions of concrete pit (mm) L l H Approximative Weight (kg) Models example: Prefatlantique Modulobloc bi or tri De 1 to 6 kva EP80 Modulobloc bi or tri 8 and 10 kva EP100 Modulobloc bi or tri 16 to 32 kva LT5 19
20 AUGIER IS CERTIFIED ISO 9001 SINCE 1995 With constant improvements, the manufacturer may alter information without prior warning AUGIER SA BP CARROS Cedex France Tel. +33 (0) Fax +33 (0)
CELLULES MEDIUM VOLTAGE
CELLULES MEDIUM VOLTAGE CEP14/15 Thoughts on the distribution of electrical energy 950 V 3200 V 5500 V 6600 V 2 CONTENTS GENERAL : The receivers. p. 4 Network transformer in a pit or compact substation.
More informationCommunication by power line carrier technology. For medium voltage networks
CELLULES STEP II CEP14/15 Communication by power line carrier technology For medium voltage networks STEP II - System Presentation Developped for networks 120 V 6,600 Volts including French standards 950
More informationDMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)
DELHI METRO RAIL CORPORATION LIMITED DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW) SPECIFICATION NO. DMES- 0005/ DMRC-E-TR-TRANSF-05 SPECIFICATIONS FOR THREE PHASE 33 kv/415 V AUXILIARY Issued on: Date
More informationDATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO
PART - A : SPECIFIC REQUIREMENTS THIS DATA SHEET IS APPLICABLE FOR IN BOILER A CLIMATIC CONDITIONS PACKAGE 1 DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.71 MTRS. 3 RELATIVE HUMIDITY 74 %
More informationPOWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS
POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS 1.0 SCOPE The following specification describes the features, design, and application of the Series 7200A
More informationCast resin transformers HARMONY TM
Cast resin transformers HARMONY TM HARMONY TM the optimum solution for higher performance At a time when we are all seeking to preserve our way of life, the production of equipment whilst ensuring safety
More informationIntroduction. Centrado leading-edge transformer. Introduction
Introduction Centrado leading-edge transformer products are designed to optimize safety and produced to deliver a great electrical power experience and solution - for factory, infrastructure, home industry,
More informationTECHNICAL SPECIFICATION FOR POWER TRANSFORMER
TECHNICAL SPECIFICATION FOR POWER TRANSFORMER NOTE: Vendor to give their offer in line with this data sheet only. Any deviations/additions/deletions shall be brought out in a separate sheet. A TECHNICAL
More informationSPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)
SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA) 0.415/33kV DESIGN AND CONSTRUCTION General 1. The transformer shall be three phase, oil immersed type, air cooled, core type, outdoor
More informationPower Quality. Case Study. Conrad Bottu Laborelec January 2008
Case Study Electromagnetic compatibility (EMC) study Breakdown of low voltage electronic equipment in a 25 kv substation Conrad Bottu Laborelec January 2008 Power Quality Power Quality 1 Introduction Description
More informationPURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS
PURCHASE SPECIFICATIONS OF 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS SPECIFICATION NO. : OR12423 REVISION NO. : Rev 00 DATE : 01.03.2011 DISTRIBUTION : PI - 4 copies O/C - 1 copy PREPARED BY
More informationSECTION TRANSFORMERS
SECTION 16460 - TRANSFORMERS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Section
More informationDRIVIA cabinets LIMOGES Cedex France 1. DESCRIPTION, USE 3. DIMENSIONS 2. RANGE, CAT. NO. EQUIVALENCE TABLE
87045 LIMOGES Cedex France Tel: (+33) 05 55 06 87 87 Fax: (+33) 05 55 06 88 88 DRIVIA cabinets CONTENTS NTS PAGES 1. Description, use....1 2. Range, equivalence table...1 3. Dimensions...1 4. General characteristics...2
More informationI -limiter The world s fastest switching device
I S -limiter 2 I S -limiter The world s fastest switching device Reduces substation cost Solves short-circuit problems in new substations and substation extensions Optimum solution for interconnection
More informationUBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5
Page 1 of 5 1.0 GENERAL 1.1 Coordination Requirements.1 UBC Energy & Water Services.2 UBC Building Operations 1.2 Description.1 UBC requirements for Substation Transformers. 2.0 MATERIAL AND DESIGN REQUIREMENTS
More informationNEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :
NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata - 700 032, Tel : 033 2477 3126; Fax : 033 2477 2403 www.ntplindia.com SPECIFICATION NTPL MAKE MICRO-CONTROLLER BASED AUTOMATIC 50KV/10A AC HIGH VOLTAGE
More informationLow Voltage Products. Enclosed Third Harmonic Filter THF and THF star Enclosed units. Brochure THFS1GB 03_04 1SCC330003C0201
Low Voltage Products Enclosed Third Harmonic Filter and star Enclosed units Brochure S1GB 3_4 1SCC333C21 The Third Harmonic - a Growing Problem Today's electrical networks and plants are under much more
More informationP2 H2 NAMEPLATE 6 HOLES M8-10 M SCREW S1 1S2 1S3 X1 X2 X3 PARALLEL HIGH RATIO
TYPE : K52 INSULATION LEVEL : up to 24/50/125kV PRIMARY CURRENT : up to 0A up to 0A single 1 to 2 secondary cores 226 M10 205 30 2 225 30 210 20 80 65,5 6 HOLES M8-10 4 Additional MTG base 2 270 4 HOLES
More informationSPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers
SPECIFICATION GUIDE ABB VACUUM CAST COIL DRY TRANFORMERS CONTENTS 1. General 1.1. Codes and standards 1.2. Service conditions 1.3. System characteristics 1.4. Documentation 2. Design and construction 2.1.
More informationPower Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.
Power Voltage Transformers for Air Insulated Substations THE PROVEN POWER. Introduction Trench Power Voltage Transformers (Power VTs) combine the attributes of an inductive voltage transformer with the
More informationThe NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:
Reclosers NOVA Three-Phase Recloser Functional Specification Guide Functional specification for NOVA three-phase recloser 1. Scope This specification describes the features and ratings of the NOVA recloser.
More informationPRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS. IR Values are to be read on the megger by meggering the Power transformer
PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS TESTS ON TRANSFORMERS 1. IR Values This is measured to measure the Insulation Resistance of the whole transformer. a) For 33/11 KV Power Transformer
More information(
(www.xatianhong.com) Introduction to XATH Xi'an Tianhong Electric Co., Ltd. (XATH) is a solely state-owned enterprise, set up by China Shipbuilding Industry Corporation (CSIC). It is one of the largest
More informationELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER
Approval Amendment Record Approval Date Version Description 03/05/2017 1 Initial issue PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION Page 1 of 13 Table of Contents 1. Purpose...
More informationSGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:
SGMF(T) series Onsite Mobile AC High Voltage Test System On-site AC high voltage test systems are used for voltage withstanding test, partial discharge measurement, tan delta measurement on those instrument
More informationOnsite Mobile AC High Voltage Test System
TSGMF(T) series Onsite Mobile AC High Voltage Test System Onsite mobile AC high voltage test systems are used for withstand voltage testing, partial discharge measurement, tan delta measurement to instrument
More informationMGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide
MGM Transformer Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide MGM Transformer Company 5701 Smithway Street Commerce, CA 90040 www.mgmtransformer.com Phone: 323.726.0888
More informationTECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES
INDEPENDENT POWER TRANSMISSION OPERATOR S.A. TNPRD/ SUBSTATION SPECIFICATION & EQUIPMENT SECTION October 2014 TECHNICAL DESCRIPTION 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES I. SCOPE This
More informationMESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER
Engineering Specification TECHNICAL SPECIFICATION FOR AN ESSENTIAL Version: 3 Issued: 14 October 2016 Owner: Chief Engineer Approved By: Andrew Russack Head of Engineering - Electrical PRINTOUT MAY NOT
More informationNeutral Earthing. For permanent or temporary neutral earthing in HV systems
Neutral Earthing Resistors RESISTORS For permanent or temporary neutral earthing in HV systems For continuous or temporary low-resistance neutral grounding in medium voltage systems Neutral point connection
More informationLow Voltage Products. Third Harmonic Filter THF and THF star System components for assembly and retrofitting. Catalogue THFS2GB 03_05 1SCC330004C0201
Low Voltage Products Third Harmonic Filter and star System components for assembly and retrofitting Catalogue SGB _ SCCC System components for assembly and retrofitting star, installation in the transformer
More information2kVA EARTH TESTING CURRENT INJECTION SYSTEM 4046 / 4047 DATASHEET REDPHASE INSTRUMENTS
2kVA EARTH TESTING CURRENT INJECTION SYSTEM 4046 / 4047 DATASHEET REDPHASE INSTRUMENTS Contents Section Brief Description... 1 Where and why it is used... 1.1 Induced Measureable Parameters... 1.2 Hardware
More informationWESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)
WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868) THREE-PHASE SUBSURFACE UNDERGROUND COMMERCIAL DISTRIBUTION (UCD) TRANSFORMER NOTE: This "Guide" summarizes the opinions, recommendations, and practices
More informationCompact Substation or Prefabricated Substation Inside Totally Enclosed Weatherproof Enclosure COPYRIGHT REGISTERED
Dial : (033)2677-5835 & 2667-8358 Tele Fax : (033)2667-8358 Manufacturer of Dry Type Transformers E-mail : unimag111@gmail.com Office & Factory : 26/5, Sarat Chatterjee Road, Howrah 711 104, West Bengal,
More informationCAST RESIN DRY TRANSFORMER
CAST RESIN DRY TRANSFORMER Majority owned subsidiary company of ELETTROMECCANICA COLOMBO s.a.s., Italy Elettromeccanica India Elettromeccanica India Pvt Ltd (EIPL) is a joint-venture company with Elettromeccanica,
More informationK Factor Power Transformers
Ashley-Edison AsiaElectricTransformers (UK) K Factor Power Transformers DTKF series Low Voltage Dry Type K Factor Power Transformers AET-DTKF-2004-01: Page 1 Asia Electric Transformers, Entrepreneur Business
More informationDistribution/Substation Transformer
Distribution/Substation Transformer Type VFI, Vacuum Fault Interrupter Transformer Option Functional Specification Guide Functional specification for 15 kv, 25 kv, or 35 kv vacuum fault interrupter distribution/substation
More informationMV network design & devices selection EXERCISE BOOK
MV network design & devices selection EXERCISE BOOK EXERCISES 01 - MV substation architectures 02 - MV substation architectures 03 - Industrial C13-200 MV substation 04 - Max. distance between surge arrester
More informationN. TEST TEST DESCRIPTION
Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy meters and transducers Primary injection testing capabilities
More informationSECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL
PART I: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. a.
More informationGE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class
GE Ventilated Dry-Type Transformers Secondary Substation Transformers - 5 and 15kV Class GE ventilated dry-type transformers are designed for indoor or outdoor applications in schools, hospitals, industrial
More informationN. TEST TEST DESCRIPTION
Multi function system for testing substation equipment such as: current, voltage and power transformers, over-current protection relays, energy meters and transducers Primary injection testing capabilities
More informationStand Alone Rudder Angle Indicator System
ComNav Marine Ltd. Phone: 604-207-1600 #15-13511 Crestwood Place Fax: 604-207-8008 Richmond, BC E-mail: sales@comnav.com Canada V6V 2G1 Web: www.comnavmarine.com Stand Alone Rudder Angle Indicator System
More informationSubstation Preventive Maintenance
Substation Preventive Maintenance PROVINCIAL ELECTRICITY AUTHORITY 1 Presentation Contents 1) A kind of substation 2) Electrical equipment details of AIS substation 3) Electrical equipment details of GIS
More informationsave energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers
save energy, it is precious Mfg. of all types of Distribution / Power & Furnace Transformers SYNERGY transformers SAFETY AND EFFICIENCY, COMBINED WITH LONG-TERM RELIABILITY, ARE THE HALLMARKS OF WORLD-RENOWNED
More informationGroup F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A
Group F : No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS Table : A No. Description 1. Make & Manufacturer 2. Place of Manufacturer 3. Voltage Ratio 4. Rating
More informationCable Management Solutions with DLP TM
DLP trunking system P. 374-375 Selection chart for DLP trunking system P. 397 Floor boxes & Under floor boxes Technical data P. 373 DLP U-PVC adaptable trunking system Cable Management Solutions with DLP
More informationHV Module Systems for Testing, Training and Research
HV Module Systems for Testing, Training and Research 4.0/3 Application Advantages Principle of HV circuit Smaller high-voltage (HV) test systems are necessary for research, development and quality testing
More informationRING CORE CURRENT TRANSFORMERS FOR LOW VOLTAGE TYPE AOS USER MANUAL
RING CORE CURRENT TRANSFORMERS FOR LOW VOLTAGE TYPE AOS F.T.M. S. r. l. Fabbrica trasformatori di misura Via Po, 3 20090 Opera MI - Italy Tel : +39 (0)2 576814 Fax : +39 (0)2 57605296 E-mail: info@ftmsrl.it
More informationAggravation with voltage?
Voltage Regulator Aggravation with voltage? At photovoltaic plants, long lines or increasing energy consumption?...then the voltage regulator can help Quick regulation from 300-700 ms Regulation of each
More informationMESP TECHNICAL SPECIFICATION FOR AN AUXILIARY OR ESSENTIAL SERVICES AND AUXILIARY TRANSFORMER FOR USE IN A RAILWAY SUBSTATION
Engineering Specification Head of Electrical Engineering MESP 050100-01 TECHNICAL SPECIFICATION FOR AN AUXILIARY OR ESSENTIAL SERVICES AND AUXILIARY TRANSFORMER FOR USE IN A RAILWAY SUBSTATION Version:
More informationRAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL
RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL 1 Contents 1. Application... 5 2. meter set... 6 3. BASIC REQUIREMENTS, OPERATIONAL SAFETy... 6 4. installation... 10 4.1. Mounting... 10 4.2. External
More informationCONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS
CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS Management has tentatively approved your request subject to the following conditions: 1. All distribution materials/equipment must be purchased
More informationBrown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS
SECTION 16461C - DRY TYPE TRANSFORMERS PART 1 - GENERAL 1.1 This section includes design and performance requirements for dry-type transformers rated for use on secondary distribution systems rated 600
More informationSRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS
ELECTRICAL ENGINEERING DIVISION Distribution Network Department SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS ELA T150.2 en SRA 2250/6 Resistor specification The SRA 2250/6 Resistor is intended to increase
More informationFlush Floor system LIMOGES Cedex. Phone : Fax :
87045 LIMOGES Cedex Phone : 05 55 06 87 87 Fax : 05 55 06 88 88 CONTENTS PAGES 1.Range 1 to 3 2.Installation process 4 to 8 3.Products détails 9 to 18 4.Technical characteristics 19 to 21 1 RANGE. Lid
More informationSINGLE-PHASE VSV SWITCH
Revision: September 2009 Supersedes: August 2007 SINGLE-PHASE VSV SWITCH INSTALLATION AND OPERATING MANUAL Table of Content: Page I. General...2 II. Specifications...2 III. Installation...3 IV. Maintenance...5
More informationBusbar Trunking Assembly
Busbar Trunking Assembly 00A-600A : 000V Horizontal and Vertical applications Suitable for Reliable Power Distribution to: > industry > highrise buildings - transformer to switchboards - switchboards to
More informationLocator Accessories DATA SHEETS. Accessory Range for Pipe & Cable Location Equipment
Locator Accessories DATA SHEETS Accessory Range for Pipe & Cable Location Equipment GENERAL PURPOSE SONDE The C.SCOPE 8kHz and 33kHz General Purpose Sondes are transmitters used to trace the direction
More information2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1.
TECHNICAL SPECIFICATIONS for Single Phase, 1 to 3 KVA Power Conditioner with Regulation and Distribution Constant Power 3 (CP3) CP36508A 7/15/04 1.0 General This specification covers the electrical characteristics
More information5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts
ALPHA AS Modular Distribution Boards /2 Introduction Unequipped Distribution Boards /4 Modular distribution boards / Add-on parts Assembly Kits for Unequipped Distribution Boards /6 8GK4 assembly kits
More informationKNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers
KNOW MORE ABOUT THE TRANSFORMERS Glossary Transformers Ambient temperature The existing temperature of the atmosphere surrounding a transformer installation. Ampere The practical unit of electric current.
More informationVoltage Transformers type UMZ User s Manual, Operation and Maintenance
Voltage Transformers type UMZ User s Manual, Operation and Maintenance ÿþþ Safety at first Safety instructions: Installation, connecting, operation and maintenance should be carried out by the authorised
More informationSection 2 Outdoor Voltage Transformers
Section 2 Outdoor Voltage Transformers GE Meter 130 Main St., Somersworth, NH 03878 USA & Canada: (800) 626-2004 Fax: (518) 869-2828; GE Worldwide: (518) 869-5555 2-1 120 V to 600 V BIL 10 kv Outdoor Voltage
More informationALPHA DIN Wall-Mounted. Distribution Boards
Siemens AG 008 ALPHA 160 - DIN Wall-Mounted Distribution Boards / Introduction Distribution Boards with Built-In Distribution Board Panels /4 8GK1 surface and flush-mounting with quick-assembly kits Unequipped
More information7. INSPECTION AND TEST PROCEDURES
7.1 Switchgear and Switchboard Assemblies A. Visual and Mechanical Inspection 1. Compare equipment nameplate data with drawings and specifications. 2. Inspect physical and mechanical condition. 3. Inspect
More informationPower-Sure 700. Technical Data TD158001EN. Contents
Technical Data TD158001EN Power-Sure 700 Supersedes August 2015 Contents Description Page General description... 2 Power-Sure 700 benefits.... 2 Specifications... 3 Industry standards and certifications...
More informationCompany Directive ENGINEERING SPECIFICATION EE SPEC: 5/5. Relating to 11kV Distribution Transformers
Company Directive ENGINEERING SPECIFICATION EE SPEC: 5/5 Relating to 11kV Distribution Transformers Policy Summary This specification covers the requirements for Distribution Transformers from 16kVA single
More informationSTS Fully automatic. Large graphic display. Primary injection testing capabilities: up to 3000 A, with the optional module BUX 3000
STS 4000 Multifunction substation maintenance & commissioning test system for current, voltage and power transformers. Capacitance / Tan Delta diagnostic system with the optional module TD 5000. w w w.
More informationTitle Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)
Discipline Engineering Standard NSW Category Electrical Title Substation Auxiliary Transformer from Rectifier Transformer Secondary Reference Number PDS 01 (RIC Standard: EP 05 00 00 01 SP) Document Control
More informationLIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING
LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING 1.0 General This specification covers the electrical characteristics and general
More informationDatasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C
Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P - 4-20mA output, default range supplied 0-100 C ENGLISH The TX203P RTD in-head mounted temperature transmitter connects
More information(1,5 modules per pole)
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 25kA 80A to 125A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationTOA PROFESSIONAL POWER AMP
Operating Instruction Manual TOA PROFESSIONAL POWER AMP Model P-150M, P-300M TOA ELECTRIC CO, LTD. KOBE, JAPAN Contents Precautions... 2 General Description... 2 Features... 3 Specifications... 4~5 Performance
More informationPOWER TRANSFORMERS CATALOGUE
COMPANY INFORMATION ARTRANS S.A. started off as a small factory in April 2, 1982 located in Mendoza, Argentina. Now, three decades later it is a globally recognized manufacturer of distribution, transmission,
More informationReference Number PPS 05 - (RIC Standard: EP SP)
Discipline Engineering Standard - NSW Category Electrical Title Low Voltage Isolating Transformer Reference Number PPS 05 - (RIC Standard: EP 17 00 00 11 SP) Document Control Status Date Prepared Reviewed
More informationRaised Floor system LIMOGES Cedex. Phone : Fax :
87045 LIMOGES Cedex Phone : 05 55 06 87 87 Fax : 05 55 06 88 88 Raised Floor system CONTENTS PAGES 1.Range 1 to 3 2.Installation process 4 to 10 3.Products détails 11 to 22 4.Technical characteristics
More informationCapacitive voltage transformers
Capacitive voltage transformers Outdoor operation Oil-paper insulated ECF (72 550) kv General description Capacitive voltage transformers of type ECF are used in high-voltage switchgears from 72 to 550
More informationMULTIBLOC 00.ST8 Size A, 690VAC Bottom Fitting, 1-,2-,4-pole
MULTIBLOC 00.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 00.ST8 comprises NH fuse switch disconnectors for 160A. They are designed for bottom
More informationAC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER
AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual
More information36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)
CEB STANDARD 022 : 1994 Specification for 36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE) CEYLON ELECTRICITY BOARD SRI LANKA Specification for 36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE) CEB Standard 022 : 1994
More information51-SDMS-04 SPECIFICATIONS FOR. DISTRIBUTION TRANSFORMERS UP TO 36 kv WITH ALUMINUM WINDINGS FOR DUAL SECONDARY 400/230 V AND 230/133 V
SPECIFICATIONS FOR DISTRIBUTION TRANSFORMERS UP TO 36 kv WITH ALUMINUM WINDINGS FOR DUAL SECONDARY 400/230 V AND 230/133 V This specification is property of SEC and subject to change or modification without
More informationAdvanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) CP RC Resonance circuit for GIS testing A new approach to testing gas-insulated switchgear Testing gas-insulated switchgear
More informationAmerican Electrical Institute
American Electrical Institute Oregon Electricians Continuing Education Grounding & Bonding (Article 250) 4 Hours American Electrical Institute PO Box 31131 Spokane, WA 99223 www.aeitraining.com Article
More informationSingle-Phase Mini Pad-Mounted Transformer Specification: Energy+ MPDL
Single-Phase Mini Pad-Mounted Transformer Specification: Energy+ MPDL Issued by: Approved by: Engineering Department Energy+ Inc. September 2016 Shawn Jackson, P.Eng. Approval is given in accordance with
More informationULTRA-K Series 600K - he
5 kva 500 kva ULTRA-K Series 600K - he High Efficiency K-Rated Power Conditioning Transformers Designed to be used with linear or non-linear loads. Applications: Audio / Video Recording Equipment IT Systems
More informationSpecialty Switches. Inertia Engineering & Machine Works, Inc Hardaway Road, Stockton CA 95215
Specialty Switches Inertia Engineering & Machine Works, Inc. 6665 Hardaway Road, Stockton CA 95215 Tel: 800-791-9997 Fax: 209-931-8186 E-mail: sales@inertiaworks.com Section 4 - Specialty Switches Specialty
More informationGROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER
GROUNDED ELECTRICAL POWER DISTRIBUTION Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER .0 Conductors for Electrical Power Distribution For single-phase transmission of AC power or
More informationMaintenance/Connection/Installation Service life C/O cyclesx1000
EasyPact MVS 2016 CPB100000 CPB100014 Circuit breaker. Switch disconnector. Common characteristics Number of poles Rated insulation voltage (V) Impulse withstand voltage (kv) Rated operational voltage
More information1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.
PART 1: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. 1.02
More informationArticle 250 Grounding & Bonding
Article 250 Grounding & Bonding AMERICAN ELECTRICAL INSTITUTE N16 W23217 Stone Ridge Dr. Waukesha, WI 53188 855-780-5046 www.aeitraining.com DISCLAIMER NOTE: This course is APPROVED for continuing education
More informationMV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer
PART 1: GENERAL 1.01 Transformer A. This section includes liquid filled, pad mounted distribution transformers with primary voltage of 12kV or 4.16kV (The University will determine primary voltage), with
More information2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 0640 807-0 Fax: 0640 807-259 IT system floor-standing distribution cabinet Series -IPS-F/EDS for supplying power to medical locations
More informationFor Maximum Safety. KEEp it SaFE Even in the Control Cabinets. Single-phase. Three-phase
EMC Filters For Maximum Safety Meets EMC guidelines Increases interference protection Decreases interference emissions KEEp it SaFE Even in the Control Cabinets Mains filters are used to reduce interference
More informationSERIESN50, COAXIAL CONNECTORS
SERIESN50, COAXIAL CONNECTORS DESCRIPTION CONTENTS PAGE HUBER+SUHNER N connectors are available with 50 and 75 impedance. The frequency range extends to 18 GHz, depending on the connector and cable type.
More informationNemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4
I N D U S T R I A L rev. A- INSTALLATION INSTRUCTIONS *PENDING* E77827 E77827 APPLICATION MR3 & MR6 Luminaires are suitable for use in the following areas as defined by the National Electrical Code (NEC)
More information4/2 Introduction. Marshaling Boxes 4/8 8GK1 surface-mounting distribution boards
ALPHA 630 - DIN Floor- Mounted Distribution Boards /2 Introduction Unequipped Distribution Boards /5 8GK1 surface-mounting distribution boards, IP3 /6 8GK1 surface-mounting distribution boards, IP55 Marshaling
More informationشركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.
Our Ref : 2/2018- Date : Messrs: Dear Sir, Tender 2/2018 Main Transformers You are kindly requested to quote for the supply and delivery DDP to our stores the transformers detailed in the attached schedules
More informationCurrent / residual current and voltage transformers. Current / residual current and voltage transformers
Current / residual current and voltage transformers Current / residual current and voltage transformers 1 Overview Current transformer overview DIN rail current transformer with fuse Current transformer...
More informationMobile Power Transformer Test Systm
TMPTTS Series Mobile Power Transformer Test Systm MPTTS Series Mobile Power Transformer Test System is design to test and diagnose in both single phase and three phase power transformer up to 500MVA. The
More information