1 CWDM and DWDM Testing RXT-1200 Modular Test Platform Optical Spectrum/Channel Analyzer for CWDM and DWDM Networks Using superior micro-optic design and MEMS tuning technology, the RXT-4500 OSA module measures key optical parameters such as wavelength, channel power, and OSNR. Platform Highlights Precise measurement of WDM wavelengths Wide wavelength range High wavelength accuracy and resolution Built-in wavelength reference High power sensitivity Excellent power accuracy Rugged, reliable design - No moving parts Superior shock resistance Periodic calibration not required Ultra-low power consumption Low temperature sensitivity Intuitive operation with dedicated test functions Touch screen for simple zooming and navigation Battery operating time > 8 hours Key Features S, C and C+L band wavelength ranges Fast continuous scanning - full spectrum in < 7 sec Simultaneous measurements of up to 160 channels DWDM channel spacing down to 50 GHz Channel power measurement Channel threshold detection Span power measurement Continuous sweep with min/max hold Channel frequency and wavelength delta vs. ITU grid In-band OSNR measurement High wavelength accuracy: ± 50 pm High dynamic range: > 50 db OSNR measurement: > 35 db Low Polarization Dependent Loss (PDL): < 0.3 db Universal optical interface with industry standard adaptors Supports 10/40/100 Gbps transmission modulation types DFB laser qualification DWDM channel monitoring per ITU G grid for 50/100/200 GHz spacing CWDM optical channel monitoring per ITU G grid

2 Applications CWDM The OSA module is a perfect compromise between a full blown OSA and an optical channel analyzer. The unit features the most important spectrum analysis capabilities required to install, commission and troubleshoot DWDM and CWDM networks. High reliability is achieved through a rugged mechanical design which features no moving parts and does not require periodic calibration. The hardware and user interface are optimized for simplicity - measurements settings are also kept to a minimum, making it easy to use for any skill level. Despite its simple operation, the unit still features the most critical OSA measurement capabilities such as precise power and wavelength characterization. CWDM Technology Coarse Wavelength Multiplexing (CWDM) technology is used frequently in enterprise or metro networks to increase bandwidth capacity economically. CWDM transmission systems can transport up to 16 channels (wavelengths) in the 1270 nm to 1610 nm spectrum with a 20 nm channel interval. The width of each channel is 13 nm while the remaining 7 nm is designed to be the guard band to the next channel. Due to the 20 nm channel spacing, cost-effective un-cooled lasers can be used. CWDM technology is often used to transport different types of services, e.g. Ethernet, SDH/SONET, and Fibre Channel (FC) but it has limitations in the distance over which the traffic is transported and also in the total channel count. ITU-T G CWDM Wavelength Grid Testing CWDM Networks Test parameters in a CWDM network are normally less stringent compared to DWDM systems due in part to more lenient laser wavelength tolerances and wide pass-band filters being used. Since there are no active components like Erbium Doped Fibre Amplifiers (EDFA) to create noise in a CWDM network, using a complex and expensive OSA would be an overkill and inappropriate for field testing. The RXT-4500 wide band OSA option quickly determines the presence/absence of each of the 16 wavelengths and checks their power levels accurately. Thanks to excellent sensitivity and a large 50 db dynamic range, the OSA can be connected to a 20 db monitoring tap on the OADM, making it ideal for non-intrusive channel analysis. Sophisticated MEMS tuning technology that has no moving parts, allows the unit to make faster measurements than most complex OSAs, enabling quick troubleshooting of a CWDM network. 2

3 Applications cont d DWDM DWDM Technology DWDM technology is particularly suitable for long-haul transmission systems because its supports Erbium Doped Fiber Amplification (EDFA). The ITU-T G recommendation defines the wavelengths found in the C-band ( nm) and L-band ( nm) with channel spacing at 50 GHz (0.4 nm), 100 GHz (0.8 nm) or 200 GHz (1.6 nm). Densely packed channels aren t without their limitations especially as precision lasers must keep channels exactly on target. Testing DWDM Networks Boasting impressive specifications, the OSA is suitable for lab operation or harsh field environments. An Athermal design assures calibration is valid over all temperature ranges resulting in accurate power and wavelength measurement in adverse or controlled conditions. The OSA supports C-band or C+L-band measurements with superior wavelength and channel resolution. The unit is an indispensable tool for checking critical parameters responsible for transmission faults. Critical DWDM Parameters Channel wavelength or frequency stability In-band OSNR Channel wavelength and frequency delta vs. ITU grid Levels below threshold or fluctuating over time Optical Signal-to-Noise Ratio (OSNR) below limits Excessive noise level per channel bandwidth Noisy amplifiers (EDFA) Channel Crosstalk (channels too close together) Power Tilt for channel equalization EDFA gain flatness and balancing Viewing Modes Measurements can be viewed in graphical and tabular formats and the display can be optimized on the fly during or after the test depending on what information needs to be presented. A level threshold can be set to display channels above a defined limit or it can also be used to reduce the number of overall channels viewed. Zooming - Specific channel/s can be analyzed in detail by defining a zoomed area on screen using a stylus or finger. Channel Search - Quickly identifies valid DWDM channels. Markers are placed automatically on the channel along with wavelength and level information. Peak Search/Hold Simplifies channel measurement and enables long-term stability testing of wavelength or level with drift function. Peak hold is also very useful to verify power levels before and after signal amplification (EDFA). EDFA Testing Erbium-Doped Fiber Amplifiers (EDFAs) are commonly used in DWDM networks. Ideally, amplifier gain is supposed to be flat, but several factors including wavelength, polarization, and input power influence the gain performance and thus the tilt of channels. The DWDM OSA models offers very good polarization sensitivity to ensure level measurements are not overly impacted by wavelengths having different states of polarization. With ± 0.5 db power accuracy and < 0.3 db Polarization Dependent Loss (PDL), the OSA is able to perform EDFA gain tilt measurements with an uncertainty of < 1 db. 3

4 Applications cont d 100G 100G Transmission Systems 100G systems are being deployed rapidly, resulting in a transition to multi-wavelength CFPs (C form-factor pluggable) transceivers (client-side). CFPs are key to reliable system deployment, so operators need to make sure these optical modules work error-free and can interoperate with other standards-compliant modules. CFPs presents a new set of challenges, and testing power and wavelength performance of each optical lane has become increasingly important. 10X10 Multi Source Agreement (MSA) The key impediment to faster 100GE adoption has been the high cost and high power footprint of the IEEE standardized client side CFP modules using four wavelengths. The 10X10 MSA defines a CFP module that maps 10 electrical lanes at 10 Gbps directly onto 10 lasers over single mode fiber up to 40 km. Designed primarily for 100 Gigabit Ethernet (100 GE) systems using 10 lanes of Gbps (total Gbps), the specification also supports 10 lanes of Gbps for Optical Transport Unit 4 (OTU4) applications at Gbps. 100GBASE- LR4 10 km CFP CAUI 10 x 10 Gbps Electrical 10:4 Gearbox 1295 nm Laser 1300 nm Laser 1305 nm Laser 1310 nm Laser MUX 1 Tx Fiber with 4 Wavelengths of 25 Gbps 10x10 MSA 2 km, 10 km, 40 km CFP CAUI 10 x 10 Gbps Electrical Array of 10 Lasers operajng in 1550 nm spectrum MUX 1 Tx Fiber with 10 Wavelengths of 10 Gbps 100G Service Testing Since 4X25 and 10X10 CFPs use WDM technology, simple aggregate power measurement of the wavelengths will not prove the system is operating correctly. Depending on the CFP range, wavelength levels can differ significantly due to channel insertion loss, Transmission and Dispersion Penalties (TDP). It is imperative to check that the receive power level of each optical lane falls within the CFP s sensitivity limits and not to rely on the internal diagnostics of the CFP itself. Reliable 100G Measurement The RXT-4500 OSA is ideal for testing CFP based WDM optical networks. Different models cover the required wavelength spectrum ranging from nm. Center wavelengths are measured precisely in GHz and dbm, and are presented in both graphic and tabular formats for simplified viewing and diagnostics. 4

5 Applications cont d DFB LASER/OPTICAL CHANNEL MONITOR DFB Laser Characteristic Measurement Laser performance parameters including peak wavelength, peak amplitude, SMSR (Side-Mode Suppression Ratio), and more can be evaluated. Side mode suppression ratio (SMSR) - amplitude difference between the main and largest side mode Stop band - wavelength spacing between the lower (left) and upper (right) side modes adjacent to the main mode Mode Offset - wavelength separation between the main and largest side mode Center offset - indicates how well the main mode is centered in the stop band Bandwidth - main spectral component of the DFB laser Optical Channel Monitoring DWDM and CWDM channels are scanned and detected automatically according to pre-defined ITU spectrum grids. For DWDM, this includes 50, 100 and 200 GHz channel spacings in the C and C+L bands as defined by ITU-T G recommendations. For CWDM, this covers channel spacing defined in G recommendation. Split screen Results can be displayed in spectrum or bar chart mode or together in an intuitive split screen mode. This convenient channel checker not only verifies the ITU channel #, but also the performance of each channel simplifying the installation, maintenance and upgrades of xwdm systems. Histogram function Intuitive histograms allow the user to monitor signal dynamics and identify performance change over time. Threshold Settings Being able to set alarm thresholds to visualize the current or historical status of channels is a powerful tool to optimize operational performance. Event Table Frequency drifts, power level deviations and OSNR fluctuations are listed with time stamps in a comprehensive event table which stores up to 1,000 events along with the alarm type and value detected. 5

6 Specifications SPECIFICATIONS Parameter Unit Full Band C+L Band C Band Wavelength Range nm Number of Channels # Up to 160 Channels Channel Spacing GHz 50, 100 GHz or User Defined Maximum Input Power dbm Input Power Range dbm +15 to to to -50 Absolute Channel Power Accuracy db ± 1.0 ± 0.5 ± 0.5 Power Measurement Repeatability db ± 0.1 ± 0.1 ± 0.1 Polarization Dependent Loss (PDL) db < 0.5 < 0.3 < 0.3 Absolute Wavelength Accuracy pm ± 500 ± 50 ± 50 Wavelength Repeatability pm ± 100 ± 10 ± 10 Wavelength Resolution (FWHM) nm 3.5 typical 0.35 typical 0.16 typical Wavelength Readout pm Optical Rejection Ratio (ORR) db > 40 > 40 > 40 Noise Floor dbm Sweep Time s 10 max 7 max 5 max Optical Interface Universal base with interchangeable FC, SC, LC, E2000 adaptors Notes: Unless noted, all specifications are valid at 23 C ± 2 C (73.4 F ± 3.6 F) using FCUPC connectors. The Verification Experts VeEX Inc Lakeview Court Fremont, CA USA Tel: Fax: customercare@veexinc.com 2014 VeEX Inc. All rights reserved. VeEX is a registered trademark of VeEX Inc. The information contained in this document is accurate. However, we reserve the right to change any contents at any time without notice. We accept no responsibility for any errors or omissions. In case of discrepancy, the web version takes precedence over any printed literature. D P A /11

VePAL UX400 Universal Test Platform

VePAL UX400 Universal Test Platform CWDM and DWDM Testing VePAL UX400 Universal Test Platform Optical Spectrum/Channel Analyzer for CWDM and DWDM Networks Using superior micro-optic design and MEMS tuning technology, the UX400 OSA module

More information

FX180 OCA. Platform Highlights. Key Features

FX180 OCA. Platform Highlights. Key Features Mini Optical Channel Analyzer for CWDM/DWDM Fiber Network Testing Available in two test configurations, CWDM or DWDM C-band, the FX180 measures key parameters such as wavelength, channel power, drift and

More information

Optical Spectrum Analyzer FTB-5240/FTB-5240B

Optical Spectrum Analyzer FTB-5240/FTB-5240B Optical Spectrum Analyzer FTB-5240/FTB-5240B Lab-quality, portable optical spectrum analyzer Wide spectral range: 1250 nm to 1650 nm High ORR: up to 50 dbc at 0.2 nm Wavelength accuracy: down to 15 pm

More information

CWDM Cisco CWDM wavelengths (nm)

CWDM Cisco CWDM wavelengths (nm) Cisco Enhanced Wavelength Division Multiplexing Product Line The Cisco enhanced wavelength-division multiplexing (EWDM) product line allows users to scale the speed and capacity of the services offered

More information

OPTICAL SPECTRUM ANALYZER 5240B

OPTICAL SPECTRUM ANALYZER 5240B OPTICAL SPECTRUM ANALYZER 5240B NETWORK TESTING Lab-quality, portable optical spectrum analyzer Wide spectral range: 1250 nm to 1650 nm High ORR: up to 50 dbc at 0.2 nm Wavelength accuracy: down to 15

More information

FTB-5200 Series. The most complete line of OSAs available: top resolution for all applications and channel spacings

FTB-5200 Series. The most complete line of OSAs available: top resolution for all applications and channel spacings OPTICAL SPECTRUM ANALYZERS FTB-5200 Series NETWORK TESTING OPTICAL The most complete line of OSAs available: top resolution for all applications and channel spacings Three models adapted to your reality

More information

DATASHEET 4.1. QSFP, 40GBase-LR, CWDM nm, SM, DDM, 6.0dB, 10km, LC

DATASHEET 4.1. QSFP, 40GBase-LR, CWDM nm, SM, DDM, 6.0dB, 10km, LC SO-QSFP-LR4 QSFP, 40GBASE-LR, CWDM 1270-1330nm, SM, DDM, 6.0dB, 10km, LC OVERVIEW The SO-QSFP-LR4 is a transceiver module designed for optical communication applications up to 10km. The design is compliant

More information

FTBx-5245 Optical Spectrum Analyzers

FTBx-5245 Optical Spectrum Analyzers FTBx-5245 Optical Spectrum Analyzers Features of this product are protected by: US patents 6,612,750; US patents 8,373,852; US patent 6,636,306 and equivalent patents pending and granted in other countries;

More information

SO-SFP-16GFC-ER-Dxxxx

SO-SFP-16GFC-ER-Dxxxx SO-SFP-16GFC-ER-Dxxxx SFP+, 16G/8G/4G FC, 10G FC, 10GBASE-ER, DWDM (ITU 921 to 960), SM, DDM, 40km, LC SO-SFP-16GFC-ER-Dxxxx Overview The SO-SFP-16GFC-ER-Dxxxx fiber optical SFP+ (small form pluggable)

More information

Good Things Come in Small Cubes. Cube Optics 100G Metro Evolution TREX14 01/06/14

Good Things Come in Small Cubes. Cube Optics 100G Metro Evolution TREX14 01/06/14 Good Things Come in Small Cubes Cube Optics 100G Metro Evolution TREX14 01/06/14 VO0030_5.0 01.06.2014 Page 2 Before we start talking about 100Gig Lets go back to basics and understand what we mean by

More information

Testing of DWDM + CWDM high speed systems. Christian Till Technical Sales Engineer, EXFO

Testing of DWDM + CWDM high speed systems. Christian Till Technical Sales Engineer, EXFO Testing of DWDM + CWDM high speed systems Christian Till Technical Sales Engineer, EXFO Need more bandwidth? xwdm - Class of WDM Devices Wavelength Division Multiplexing (WDM) : Access 2 channels 1310nm,

More information

Cisco QSFP-100G-LR4-S. Part Number: QSFP-100G-LR4-S QSFP-100G-LR4-S OVERVIEW PRODUCT FEATURES APPLICATIONS. FluxLight, Inc

Cisco QSFP-100G-LR4-S. Part Number: QSFP-100G-LR4-S QSFP-100G-LR4-S OVERVIEW PRODUCT FEATURES APPLICATIONS. FluxLight, Inc Part Number: QSFP-100G-LR4-S QSFP-100G-LR4-S OVERVIEW The QSFP-100G-LR4-S is a 100 Gbps transceiver module designed for optical communication applications compliant to 100GBASE-LR4 of the IEEE P802.3ba

More information

5240B OPTICAL SPECTRUM ANALYZER FTB-5240/FTB-5240B. Telecom Test and Measurement. Lab-quality, portable optical spectrum analyzer

5240B OPTICAL SPECTRUM ANALYZER FTB-5240/FTB-5240B.  Telecom Test and Measurement. Lab-quality, portable optical spectrum analyzer 5240B NETWORK TESTING OPTICAL SPECTRUM ANALYZER FTB-5240/FTB-5240B Lab-quality, portable optical spectrum analyzer Wide spectral range: 1250 nm to 1650 nm High ORR: up to 50 dbc at 0.2 nm Wavelength accuracy:

More information

40GBd QSFP+ LR4 Optical Transceiver

40GBd QSFP+ LR4 Optical Transceiver Preliminary DATA SHEET CFORTH-QSFP-40G-LR4 40GBd QSFP+ LR4 Optical Transceiver CFORTH-QSFP-40G-LR4 Overview CFORTH-QSFP-40G-LR4 QSFP+ LR4 optical transceivers are based on Ethernet IEEE P802.3ba standard

More information

Q8384 Q8384. Optical Spectrum Analyzer

Q8384 Q8384. Optical Spectrum Analyzer Q8384 Optical Spectrum Analyzer Can measure and evaluate ultra high-speed optical DWDM transmission systems, and optical components at high wavelength resolution and high accuracy. New high-end optical

More information

CISCO DWDM GBICS. Figure 1. Cisco DWDM GBICs. Main features of the Cisco DWDM GBICs:

CISCO DWDM GBICS. Figure 1. Cisco DWDM GBICs. Main features of the Cisco DWDM GBICs: DATA SHEET CISCO DWDM GBICS The Cisco Dense Wavelength-Division Multiplexing (DWDM) Gigabit Interface Converter (GBIC) pluggables allow enterprise companies and service providers to provide scalable and

More information

Innovations in Photonic Integration Platforms

Innovations in Photonic Integration Platforms Innovations in Photonic Integration Platforms September 20, 20 Burgeoning Growth Demand Disruptive Technology Video content is fast becoming a larger percentage of total internet traffic 50% Video services

More information

Qualifying Fiber for 10G Deployment

Qualifying Fiber for 10G Deployment Qualifying Fiber for 10G Deployment Presented by: Bob Chomycz, P.Eng. Email: BChomycz@TelecomEngineering.com Tel: 1.888.250.1562 www.telecomengineering.com 2017, Slide 1 of 25 Telecom Engineering Introduction

More information

Pluggable Transceivers

Pluggable Transceivers DATA SHEET Pluggable Transceivers Industry-Standard Pluggable Transceivers and Direct Attach Cables BENEFITS BUSINESS ALIGNMENT Standards-based technology. Flexible interface options for 100Mbs, 1Gbps,10Gbps,

More information

IQS/FLS-2600B TUNABLE LASER SOURCE

IQS/FLS-2600B TUNABLE LASER SOURCE TUNABLE LASER SOURCE IQS/FLS-2600B R&D MANUFACTURING Continuous and precise tuning over the C and L bands 100 nm tuning range ±15 pm uncertainty Inherent coherence control ±0.005 db power stability S/SSE

More information

Consideration about wavelength allocation in O-band

Consideration about wavelength allocation in O-band IEEE P802.3ca -EPON Task Force meeting, Whistler Consideration about wavelength allocation in O-band Tomoyuki Funada May 24-25, 2016 Introduction 29dB channel insertion loss with 25Gbps/lane is challenging.

More information

Extending 100Gbit/s Ethernet. Ariën Vijn

Extending 100Gbit/s Ethernet. Ariën Vijn Extending 100Gbit/s Ethernet Ariën Vijn arien.vijn@ams-ix.net Agenda AMS-IX 100Gbit/s technology Problem statement Optical Amplifier development Metro DWDM equipment AMS-IX AMS-IX 100Gbit/s technology

More information

Why Using Fiber for transmission

Why Using Fiber for transmission Why Using Fiber for transmission Why Using Fiber for transmission Optical fibers are widely used in fiber-optic communications, where they permit transmission over long distances and at very high bandwidths.

More information

Module 19 : WDM Components

Module 19 : WDM Components Module 19 : WDM Components Lecture : WDM Components - I Part - I Objectives In this lecture you will learn the following WDM Components Optical Couplers Optical Amplifiers Multiplexers (MUX) Insertion

More information

FTBx-5245/5255 Optical Spectrum Analyzers

FTBx-5245/5255 Optical Spectrum Analyzers FTBx-5245/5255 Optical Spectrum Analyzers 2011 GLOBAL PORTABLE FIBER OPTIC TEST EQUIPMENT MARKET SHARE LEADERSHIP AWARD 2015 GLOBAL FIBER OPTIC TEST EQUIPMENT MARKET LEADERSHIP AWARD Features of this product

More information

Filling the fiber: Factors involved in absolute fiber capacity Geoff Bennett, Infinera UKNOF September 2007

Filling the fiber: Factors involved in absolute fiber capacity Geoff Bennett, Infinera UKNOF September 2007 Filling the fiber: Factors involved in absolute fiber capacity Geoff Bennett, Infinera UKNOF September 2007 Initial assumption We are aiming to achieve the highest possible capacity from an individual

More information

Long-Haul DWDM RF Fiber Optic Link System

Long-Haul DWDM RF Fiber Optic Link System EMCORE Corporation - Broadband Division, Alhambra, CA, USA ABSTRACT EMCORE s vertically integrated ISO-9001 facility, staffed with our optics/rf engineering team, has been successfully designing and manufacturing

More information

100Gbs QSFP28 LR4 Optical Transceiver Module WT-QSFP28-LR4

100Gbs QSFP28 LR4 Optical Transceiver Module WT-QSFP28-LR4 100Gbs QSFP28 LR4 Optical Transceiver Module WT-QSFP28-LR4 Features Hot pluggable QSFP28 MSA form factor Compliant to IEEE 802.3ba 100GBASE-LR4 Up to 10km reach for G.652 SMF Single +3.3V power supply

More information

Analysis of four channel CWDM Transceiver Modules based on Extinction Ratio and with the use of EDFA

Analysis of four channel CWDM Transceiver Modules based on Extinction Ratio and with the use of EDFA Analysis of four channel CWDM Transceiver Modules based on Extinction Ratio and with the use of EDFA P.P. Hema [1], Prof. A.Sangeetha [2] School of Electronics Engineering [SENSE], VIT University, Vellore

More information

CFORTH-QSFP28-100G-LR4 Specifications Rev. D00B. Product Features

CFORTH-QSFP28-100G-LR4 Specifications Rev. D00B. Product Features Preliminary DATA SHEET CFORTH-QSFP28-100G-LR4 100G QSFP28 LR4 Optical Transceiver CFORTH-QSFP28-100G-LR4 Overview CFORTH-QSFP28-100G-LR4 QSFP28 LR4 optical transceivers are based on 100G Ethernet IEEE

More information

DS-8G-ZR-Dxxxx. SFP+, 8/4/2/1 Gbps FC/FICON, DWDM, SM, DDM, 23dB, 80km. DS-8G-ZR-Dxxxx OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION

DS-8G-ZR-Dxxxx. SFP+, 8/4/2/1 Gbps FC/FICON, DWDM, SM, DDM, 23dB, 80km. DS-8G-ZR-Dxxxx OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION DS-8G-ZR-Dxxxx SFP+, 8/4/2/1 Gbps FC/FICON, DWDM, SM, DDM, 23dB, 80km DS-8G-ZR-Dxxxx OVERVIEW The DS-8G-ZR-Dxxxx fiber optical SFP+ (small form pluggable) transceivers are uniquely layer 1 tested and approved

More information

DATASHEET G Data Center Interconnect (DCI) 100G Embedded DWDM (DWDM transciever in to Ethernet switch with no OEO transponder requirement)

DATASHEET G Data Center Interconnect (DCI) 100G Embedded DWDM (DWDM transciever in to Ethernet switch with no OEO transponder requirement) SO-QSFP28-PAM4-Dxxxx QSFP28, 100GBase, PAM4, DWDM, SM, DDM, 80km*, LC OVERVIEW The SO-QSFP28-PAM4-Dxxxx is a pluggable QSFP28 DWDM transceiver designed for high capacity 100 Gigabit Ethernet (100GbE) Data

More information

Optical Measurements in 100 and 400 Gb/s Networks: Will Coherent Receivers Take Over? Fred Heismann

Optical Measurements in 100 and 400 Gb/s Networks: Will Coherent Receivers Take Over? Fred Heismann Optical Measurements in 100 and 400 Gb/s Networks: Will Coherent Receivers Take Over? Fred Heismann Chief Scientist Fiberoptic Test & Measurement Key Trends in DWDM and Impact on Test & Measurement Complex

More information

F i n i s a r. Product Specification. Long-Reach DWDM SFP Transceiver FWLF1631Rxx PRODUCT FEATURES

F i n i s a r. Product Specification. Long-Reach DWDM SFP Transceiver FWLF1631Rxx PRODUCT FEATURES Product Specification Long-Reach DWDM SFP Transceiver FWLF1631Rxx PRODUCT FEATURES Up to 2.7 Gb/s bi-directional data links High launch power (+3dBm MIN) Hot-pluggable SFP footprint Temperature-stabilized

More information

Odd. Even. Insertion Loss (db)

Odd. Even. Insertion Loss (db) Optical Interleavers Optoplex s Optical Interleaver products are based on our patented Step-Phase Interferometer design. Used as a DeMux (or Mux) device, an optical interleaver separates (or combines)

More information

Field Optical Spectrum Analyser

Field Optical Spectrum Analyser NEWSLETTER JANUARY 2004 5 Field Optical Spectrum Analyser There is a growing number of applications in today's telecom world involving fibre optic communications using more than one wavelength on the same

More information

WDM. Coarse WDM. Nortel's WDM System

WDM. Coarse WDM. Nortel's WDM System WDM wavelength-division multiplexing (WDM) is a technology which multiplexes a number of optical carrier signals onto a single optical fiber by using different wavelengths (i.e. colors) of laser light.

More information

QSFP SFP-QSFP-40G-LR4

QSFP SFP-QSFP-40G-LR4 Features Compliant with 40G Ethernet IEEE802.3ba and 40GBASE-LR4 Standard QSFP+ MSA compliant Compliant with QDR/DDR Infiniband data rates Up to 11.2Gb/s data rate per wavelength 4 CWDM lanes MUX/DEMUX

More information

GM8036 LASER ANALYZER SWEEP SPECTRUM OPTICAL. Technical Specifications v1.01 March, 2011

GM8036 LASER ANALYZER SWEEP SPECTRUM OPTICAL. Technical Specifications v1.01 March, 2011 GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011 GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) UC INSTRUMENTS GM8036 laser sweep

More information

CFP4. Parameter Symbol Min Max Units Notes. Storage Temperature Ts degc. Relative Humidity (non-condensation) RH 85 %

CFP4. Parameter Symbol Min Max Units Notes. Storage Temperature Ts degc. Relative Humidity (non-condensation) RH 85 % Features Hot pluggable CFP4 MSA form factor Compliant to Ethernet 100GBASE-ER4 Lite, OTN OTU4 4L1-9C1F Lite, and CFP-MSA- HW-Specification Supports 103.1Gb/s and 112Gb/s aggregate bit rates Up to 25km

More information

SO-CFP4-LR4. CFP4, 103/112 Gbps, 1310nm, SM, DDM, 6.3dB, 10km OVERVIEW PRODUCT FEATURES ORDERING INFORMATION DATASHEET 4.1

SO-CFP4-LR4. CFP4, 103/112 Gbps, 1310nm, SM, DDM, 6.3dB, 10km OVERVIEW PRODUCT FEATURES ORDERING INFORMATION DATASHEET 4.1 SO-CFP4-LR4 CFP4, 103/112 Gbps, 1310nm, SM, DDM, 6.3dB, 10km OVERVIEW The SO-CFP4-LR4 is a 100Gbps transceiver module designed for optical communication applications compliant to 100GBASE-LR4 of the IEEE

More information

100G CWDM4 MSA Technical Specifications 2km Optical Specifications

100G CWDM4 MSA Technical Specifications 2km Optical Specifications 100G CWDM4 MSA Technical Specifications 2km Specifications Participants Editor David Lewis, LUMENTUM Comment Resolution Administrator Chris Cole, Finisar The following companies were members of the CWDM4

More information

DWDM XFP Series. XFPD-ER-T and XFPD-ER-T1 Single-Mode Tunable XFP Transceiver RoHS6 Compliant. Features. Applications. Product description

DWDM XFP Series. XFPD-ER-T and XFPD-ER-T1 Single-Mode Tunable XFP Transceiver RoHS6 Compliant. Features. Applications. Product description XFPD-ER-T and XFPD-ER-T1 Single-Mode Tunable XFP Transceiver RoHS6 Compliant Features Available in all C-Band Wavelengths on the 50GHz DWDM ITU Grid Supports 8.5Gb/s to 11.35Gb/s bit Rates Hot-Pluggable

More information

Passive WDM Networking

Passive WDM Networking Passive WDM Networking Company Introduction designs and markets all types of fibre optical Product portfolio: transmission products. Headquarted in Oslo, Norway, we serve Storage, Data and Telecom Networks

More information

Ultra high resolutions : 140 MHz/1.12 pm ; 20 MHz/0.16 pm ; 5 MHz/0.04 pm... Features:

Ultra high resolutions : 140 MHz/1.12 pm ; 20 MHz/0.16 pm ; 5 MHz/0.04 pm... Features: BASED ON AN INTERFEROMETRIC PRINCIPLE, APEX TECHNOLOGIES ULTRA HIGH RESOLUTION OPTICAL SPECTRUM ANALYZER CAN ACHIEVE A 500 TIMES BETTER RESOLUTION THAN MONOCHROMATOR OPTICAL SPECTRUM ANALYZER The APEX

More information

SPECTRAL HOLE BURNING EFFECTS AND SYSTEM ENGINEERING RULES FOR SYSTEM UPGRADES

SPECTRAL HOLE BURNING EFFECTS AND SYSTEM ENGINEERING RULES FOR SYSTEM UPGRADES SPECTRAL HOLE BURNING EFFECTS AND SYSTEM ENGINEERING RULES FOR SYSTEM UPGRADES Richard Oberland, Steve Desbruslais, Joerg Schwartz, Steve Webb, Stuart Barnes richard@azea.net Steve Desbruslais, Joerg Schwartz,

More information

MEMS Tunable Filter Products

MEMS Tunable Filter Products Optoplex TM C O R P O R A T I O N TM MEMS Tunable Filter Products MEMS Technology Optoplex s MEMS Tunable Optical Filter is based on a patented micro-optic design with MEMS tuning technology. It is an

More information

Wavelength-Enhanced Passive Optical Networks with Extended Reach

Wavelength-Enhanced Passive Optical Networks with Extended Reach Wavelength-Enhanced Passive Optical Networks with Extended Reach Ken Reichmann and Pat Iannone Optical Systems Research AT&T Labs, Middletown NJ Thanks to Han Hyub Lee, Xiang Zhou, and Pete Magill Wavelength-Enhanced

More information

QSFP SV-QSFP-40G-LR4L

QSFP SV-QSFP-40G-LR4L Features 4 CWDM lanes MUX/DEMUX design Up to 11.2Gb/s data rate per wavelength QSFP+ MSA compliant IEEE 802.3ba Electrical Interface Up to 2km transmission on single mode fiber (SMF) Operating case temperature:

More information

GS7000 and GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System

GS7000 and GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System GS7000 and GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System The bdr Digital Reverse 2:1 Multiplexing System expands the functionality of the GS7000 and GainMaker Reverse Segmentable

More information

Highly Reliable 40-mW 25-GHz 20-ch Thermally Tunable DFB Laser Module, Integrated with Wavelength Monitor

Highly Reliable 40-mW 25-GHz 20-ch Thermally Tunable DFB Laser Module, Integrated with Wavelength Monitor Highly Reliable 4-mW 2-GHz 2-ch Thermally Tunable DFB Laser Module, Integrated with Wavelength Monitor by Tatsuya Kimoto *, Tatsushi Shinagawa *, Toshikazu Mukaihara *, Hideyuki Nasu *, Shuichi Tamura

More information

DWDM XENPAK Transceiver, 32 wavelengths, SC Connectors, 80km over Single Mode Fiber

DWDM XENPAK Transceiver, 32 wavelengths, SC Connectors, 80km over Single Mode Fiber CFORTH-DWDM-XENPAK-xx.xx Specifications Rev. D00B Preiminary DATA SHEET CFORTH-DWDM-XENPAK-xx.xx DWDM XENPAK Transceiver, 32 wavelengths, SC Connectors, 80km over Single Mode Fiber CFORTH-DWDM-XENPAK-xx.xx

More information

11.1 Gbit/s Pluggable Small Form Factor DWDM Optical Transceiver Module

11.1 Gbit/s Pluggable Small Form Factor DWDM Optical Transceiver Module INFORMATION & COMMUNICATIONS 11.1 Gbit/s Pluggable Small Form Factor DWDM Transceiver Module Yoji SHIMADA*, Shingo INOUE, Shimako ANZAI, Hiroshi KAWAMURA, Shogo AMARI and Kenji OTOBE We have developed

More information

White Paper. 100G beyond 10km A global study coherent and PAM4 Technology. Date: By Ambroise Thirion

White Paper. 100G beyond 10km A global study coherent and PAM4 Technology. Date: By Ambroise Thirion White Paper Date: 100G beyond 10km A global study coherent and PAM4 Technology By Ambroise Thirion Contents I. II. III. IV. The challenge of going beyond 10km on 100G links...3 Long reach technologies

More information

Technical Specifications

Technical Specifications APPENDIXB This appendix includes the following sections: Switch Specifications, page B-1 Module Specifications, page B-2 Power Specifications, page B-4 X2 Transceiver Specifications, page B-7 and + Transceiver

More information

Product Specification. 10Gb/s 200km Telecom CML TM 13pin-GPO Butterfly Transmitter DM /1/2

Product Specification. 10Gb/s 200km Telecom CML TM 13pin-GPO Butterfly Transmitter DM /1/2 Product Specification 10Gb/s 200km Telecom CML TM 13pin-GPO Butterfly Transmitter DM200-01-0/1/2 PRODUCT FEATURES High Performance CML TM Supports multi-bit-rate application, from 9.95Gb/s to 11.1Gb/s

More information

Introduction to BER testing of WDM systems

Introduction to BER testing of WDM systems Introduction to BER testing of WDM systems Application note 1299 Wavelength division multiplexing (WDM) is a new and exciting technology for migrating the core optical transmission network to higher bandwidths.

More information

Class 1 LED of 850 nm for (short-range) applications. Class 1 laser of 1300 nm for (medium-range) applications.

Class 1 LED of 850 nm for (short-range) applications. Class 1 laser of 1300 nm for (medium-range) applications. Product Number WS-G5482 WS-G5483 GLC-T WS-X3500-XL CAB-SFP-50CM WS-G5484 WS-G5486 WS-G5487 GLC-BX-U GLC-BX-D GLC-SX-MM GLC-LH-SM GLC-ZX-SM GLC-GE-100FX CWDM-GBICxxxx CWDM-SFPxxxx DWDM-GBICxxxx XENPAK-xxxx

More information

Improved Analysis of Hybrid Optical Amplifier in CWDM System

Improved Analysis of Hybrid Optical Amplifier in CWDM System Improved Analysis of Hybrid Optical Amplifier in CWDM System 1 Bandana Mallick, 2 Reeta Kumari, 3 Anirban Mukherjee, 4 Kunwar Parakram 1. Asst Proffesor in Dept. of ECE, GIET Gunupur 2, 3,4. Student in

More information

DATASHEET 4.1. XFP, 10GBase-ZR, Multirate Gbps, DWDM 50GHz, SM, DDM, 24dB, 80km

DATASHEET 4.1. XFP, 10GBase-ZR, Multirate Gbps, DWDM 50GHz, SM, DDM, 24dB, 80km SO-XFP-ZR-50G-Dxxxx XFP, 10GBase-ZR, Multirate 9.95-11.1 Gbps, DWDM, 50GHz, SM, DDM, 24dB, 80km OVERVIEW The E SO-XFP-ZR-50G-Dxxxx series single mode transceiver is small form factor pluggable module for

More information

X2-10GB-Cxx-ER CWDM X2-10GBASE, 40km Reach

X2-10GB-Cxx-ER CWDM X2-10GBASE, 40km Reach X2-10GB-Cxx-ER CWDM X2-10GBASE, 40km Reach Features Wavelength selectable to ITU-T standards covering CWDM grid Compatible with X2 MSA Rev2.0b Support of IEEE 802.3ae 10GBASE-ER at 10.3125Gbps Transmission

More information

EDFA Applications in Test & Measurement

EDFA Applications in Test & Measurement EDFA Applications in Test & Measurement White Paper PN 200-0600-00 Revision 1.1 September 2003 Calmar Optcom, Inc www.calamropt.com Overview Erbium doped fiber amplifiers (EDFAs) amplify optical pulses

More information

Cisco ONS Pluggable Optics Series Modules for the Carrier Packet Transport (CPT) Platform

Cisco ONS Pluggable Optics Series Modules for the Carrier Packet Transport (CPT) Platform :: Seite 1 von 15 :: Datenblatt zum Produkt Cisco SFP -10/100 B-D ET mit DC# 633546 :: Cisco ONS Pluggable Optics Series Modules for the Carrier Packet Transport (CPT) Platform This document provides technical

More information

40G-QSFP-ER4-LEG. 40Gbase QSFP+ Transceiver

40G-QSFP-ER4-LEG. 40Gbase QSFP+ Transceiver Part# 39606 40G-QSFP-ER4-LEG BROCADE COMPATIBLE 40GBASE-ER4 QSFP+ SMF 1271-1331NM 30KM REACH LC DOM 40G-QSFP-ER4-LEG 40Gbase QSFP+ Transceiver Features Compliant with 40G Ehternet IEEE802.3ba and 40GBase-ER4

More information

DATA SHEET: Transceivers

DATA SHEET: Transceivers ProLabs QSFP 40G ER4 C 40GBASE ER4 QSFP+ SMF 1271 1331NM 30KM REACH LC DOM DATA SHEET: Transceivers QSFP-40G-ER4-C Overview ProLabs QSFP 40G ER4 C Quad Small Form Factor Pluggable (QSFP+) transceivers

More information

Proposal for 4-channel WDM (WDM4) for intermediate reach 100GbE SMF PMD

Proposal for 4-channel WDM (WDM4) for intermediate reach 100GbE SMF PMD Proposal for 4-channel WDM (WDM4) for intermediate reach 100GbE SMF PMD Contributors Yurii Vlasov Douglas Gill IBM IBM 802.3bm Plenary Meeting, November 13, San Antonio, TX 1 Supporters Stefan Rochus Mounir

More information

Agilent 83430A Lightwave Digital Source Product Overview

Agilent 83430A Lightwave Digital Source Product Overview Agilent Lightwave Digital Source Product Overview SDH/SONET Compliant DFB laser source for digital, WDM, and analog test up to 2.5 Gb/s 52 Mb/s STM-0/OC-1 155 Mb/s STM-1/OC-3 622 Mb/s STM-4/OC-12 2488

More information

DATASHEET 4.1. SFP+, 10GBase-ZR, Multirate Gbps, C Tunable, DWDM, C-Band, 50GHz, 22dB, 80km, ind. temp.

DATASHEET 4.1. SFP+, 10GBase-ZR, Multirate Gbps, C Tunable, DWDM, C-Band, 50GHz, 22dB, 80km, ind. temp. SO-SFP-10G-ZR-DWDM-I SFP+, 10GBase-ZR, Multirate 9.95-11.1 Gbps, C Tunable, DWDM, C-Band, 50GHz, 22dB, 80km, ind. temp. OVERVIEW The SO-SFP-10G-ZR-DWDM-I Tunable SFP+ Optical Transceiver is a full duplex,

More information

GS7000 & GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System

GS7000 & GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System Optoelectronics GS7000 & GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System Description The bdr Digital Reverse 2:1 Multiplexing System expands the functionality of the Scientific-Atlanta

More information

Dr. Monir Hossen ECE, KUET

Dr. Monir Hossen ECE, KUET Dr. Monir Hossen ECE, KUET 1 Outlines of the Class Principles of WDM DWDM, CWDM, Bidirectional WDM Components of WDM AWG, filter Problems with WDM Four-wave mixing Stimulated Brillouin scattering WDM Network

More information

Optical Spectrum Analyzer AQ6331. A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.

Optical Spectrum Analyzer AQ6331. A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance. Optical Spectrum Analyzer AQ6331 A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance. Compact, lightweight and high-spec! The AQ6331 is a new portable

More information

CFP2. Parameter Symbol Min Max Units Notes. Storage Temperature Ts degc. Relative Humidity (non-condensation) RH 85 %

CFP2. Parameter Symbol Min Max Units Notes. Storage Temperature Ts degc. Relative Humidity (non-condensation) RH 85 % Features Hot pluggable CFP2 MSA form factor Compliant to IEEE 802.3ba 100GBASE-LR4 and CFP-MSA-Specification Supports 103.1Gb/s aggregate bit rate Up to 10km reach for G.652 SMF Single +3.3V power supply

More information

Model 6944 and 6940 Node bdr Digital Reverse 4:1 Multiplexing System designed for Prisma II Platform

Model 6944 and 6940 Node bdr Digital Reverse 4:1 Multiplexing System designed for Prisma II Platform Optoelectronics Model 6944 and 6940 Node bdr Digital Reverse 4:1 Multiplexing System designed for Prisma II Platform Description The bdr Digital Reverse 4:1 Multiplexing System expands the functionality

More information

Keysight Technologies Wavelength and polarization dependence of 100G-LR4 components. Application Note

Keysight Technologies Wavelength and polarization dependence of 100G-LR4 components. Application Note Keysight Technologies Wavelength and polarization dependence of 100G-LR4 components Application Note 02 Keysight Wavelength-dependence measurements for 100G-LR4 components - Application Note O-band WDM

More information

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions Data Center & Cloud Computing DATASHEET 18 Channels Dual Fiber CWDM Mux Demux + Monitor Port 1270-1610nm, 1U Rack Mount, LC/UPC Data Center & Cloud Computing Infrastruture Solutions REV.1.0 2017 01 Overview

More information

Supercontinuum Sources

Supercontinuum Sources Supercontinuum Sources STYS-SC-5-FC (SM fiber coupled) Supercontinuum source SC-5-FC is a cost effective supercontinuum laser with single mode FC connector output. With a total output power of more than

More information

International Journal of Advanced Research in Computer Science and Software Engineering

International Journal of Advanced Research in Computer Science and Software Engineering Volume 3, Issue 4, April 2013 ISSN: 2277 128X International Journal of Advanced Research in Computer Science and Software Engineering Research Paper Available online at: www.ijarcsse.com Design and Performance

More information

771 Series LASER SPECTRUM ANALYZER. The Power of Precision in Spectral Analysis. It's Our Business to be Exact! bristol-inst.com

771 Series LASER SPECTRUM ANALYZER. The Power of Precision in Spectral Analysis. It's Our Business to be Exact! bristol-inst.com 771 Series LASER SPECTRUM ANALYZER The Power of Precision in Spectral Analysis It's Our Business to be Exact! bristol-inst.com The 771 Series Laser Spectrum Analyzer combines proven Michelson interferometer

More information

DWDM XENPAK Transceivers, 32 wavelengths, SC Connectors, 80km over Single Mode Fiber

DWDM XENPAK Transceivers, 32 wavelengths, SC Connectors, 80km over Single Mode Fiber DATA SHEET DWDM XENPAK Transceivers, 32 wavelengths, SC Connectors, 80km over Single Mode Fiber Overview Agilestar's DWDM 10GBd XENPAK optical transceiver is designed for Storage, IP network and LAN, it

More information

100G Coherent Transceiver Technologies for DWDM Metro Applications: Key Requirements and Design Trends

100G Coherent Transceiver Technologies for DWDM Metro Applications: Key Requirements and Design Trends 100G Coherent Transceiver Technologies for DWDM Metro Applications: Key Requirements and Design Trends Benny Mikkelsen benny.mikkelsen@acacia-inc.com ECOC, 2012 Market Focus Optical Networks Advances Outline

More information

CX380X Advanced Spectrum and Burst QAM Analyzer

CX380X Advanced Spectrum and Burst QAM Analyzer Advanced Spectrum and Burst QAM Analyzer Preventative Network Monitoring With VeEX s VeSion system, the advanced Spectrum Analyzer and Bursty Demodulator captures rogue cable modems and provides proactive

More information

Emerging Highly Compact Amplification Solutions for Coherent Transmission

Emerging Highly Compact Amplification Solutions for Coherent Transmission Emerging Highly Compact Amplification Solutions for Coherent Transmission Market Focus ECOC 2017 Sep 20, 2017 Dr. Sanjai Parthasarathi Vice President, Product Marketing & Strategy II-VI Photonics Outline

More information

Further more all functions as well available in splice trays or splice enclosures (-40 to 85 C)

Further more all functions as well available in splice trays or splice enclosures (-40 to 85 C) NETWORK-Cubes Cube Optics NETWORK-Cubes The Cube Optics Coarse Wavelength Division Multiplexing NETWORK-Cubes are a flexible plugand-play network solution that allows service providers and enterprise companies

More information

FTB-5500B/FTB-5800 PMD AND CD ANALYZERS

FTB-5500B/FTB-5800 PMD AND CD ANALYZERS FTB-5500B/FTB-5800 PMD AND CD ANALYZERS GLOBAL PORTABLE FIBER OPTIC TEST EQUIPMENT MARKET LEADERSHIP AWARD * Protected by US patent 7,227,645 and equivalents in several other countries. ** Protected by

More information

OPC1600 MUX WDM OADM SPLITTER

OPC1600 MUX WDM OADM SPLITTER OPC1600 MUX WDM OADM SPLITTER OPC 1600 passive optical splitting platform The OPC 1600 optical splitting platform could, without affecting the original link, fully duplicates one or more copies of data

More information

Thursday, April 17, 2008, 6:28:40

Thursday, April 17, 2008, 6:28:40 Wavelength Division Multiplexing By: Gurudatha Pai K gurudatha@gmail.com Thursday, April 17, 2008, 6:28:40 Overview Introduction Popular Multiplexing Techniques Optical Networking WDM An Analogy of Multiplexing

More information

GYM Bilgi Teknolojileri

GYM Bilgi Teknolojileri SFP Transceiver Module GLC SX MM GLC SX MM is 1000Base-SX SFP fiber optic transceiver for multimode fiber and it works at 850nm wavelength, Cisco GLC SX MM SFP is compatible with IEEE 802.3z and could

More information

DWDM XFP Series XFPD-ER. XFP Single-Mode Dual Fiber DWDM Transceiver for 10GbE/10GFC/SDH/SONET. Features. Applications. Product Description

DWDM XFP Series XFPD-ER. XFP Single-Mode Dual Fiber DWDM Transceiver for 10GbE/10GFC/SDH/SONET. Features. Applications. Product Description XFPD-ER XFP Single-Mode Dual Fiber DWDM Transceiver for 10GbE/10GFC/SDH/SONET Features 100GHz ITU Grid, C Band 10 Gbit/s Data Rate 14dB Power Budget Built-in Digital Diagnostics Applications 10GBASE-ER/EW

More information

Agilent 81980/ 81940A, Agilent 81989/ 81949A, Agilent 81944A Compact Tunable Laser Sources

Agilent 81980/ 81940A, Agilent 81989/ 81949A, Agilent 81944A Compact Tunable Laser Sources Agilent 81980/ 81940A, Agilent 81989/ 81949A, Agilent 81944A Compact Tunable Laser Sources December 2004 Agilent s Series 819xxA high-power compact tunable lasers enable optical device characterization

More information

Design of an Optical Submarine Network With Longer Range And Higher Bandwidth

Design of an Optical Submarine Network With Longer Range And Higher Bandwidth Design of an Optical Submarine Network With Longer Range And Higher Bandwidth Yashas Joshi 1, Smridh Malhotra 2 1,2School of Electronics Engineering (SENSE) Vellore Institute of Technology Vellore, India

More information

FTB-5500B/FTB PMD and CD Analyzers. Polarization Mode Dispersion Analyzer FTB-5500B. Chromatic Dispersion Analyzer FTB-5800**

FTB-5500B/FTB PMD and CD Analyzers. Polarization Mode Dispersion Analyzer FTB-5500B. Chromatic Dispersion Analyzer FTB-5800** FTB-5500B/FTB-5800 NETWORK TESTING OPTICAL Polarization Mode Dispersion Analyzer FTB-5500B Less than five-second testing time for any PMD range No auto-correlation peak, for enhanced accuracy NIST traceable

More information

100GHz WAVELENGTH DIVISION MULTIPLEXER/ DEMULTIPLEXER (APMUX1100 / APDMX1100)

100GHz WAVELENGTH DIVISION MULTIPLEXER/ DEMULTIPLEXER (APMUX1100 / APDMX1100) Planar Waveguide Components 100GHz WAVELENGTH DIVISION MULTIPLEXER/ DEMULTIPLEXER (APMUX1100 / APDMX1100) APMUX1100 and APDMX1100 are arrayed-waveguide grating (AWG) wavelength division multiplexers and

More information

FTB-5500B/FTB-5800 PMD AND CD ANALYZERS. Telecom Test and Measurement. Polarization Mode Dispersion Analyzer FTB-5500B

FTB-5500B/FTB-5800 PMD AND CD ANALYZERS.  Telecom Test and Measurement. Polarization Mode Dispersion Analyzer FTB-5500B PMD AND CD ANALYZERS FTB-5500B/FTB-5800 NETWORK TESTING OPTICAL Polarization Mode Dispersion Analyzer FTB-5500B Less than five-second testing time for any PMD range No auto-correlation peak, for enhanced

More information

Arista QSFP-40G-PLR4. Part Number: QSFP-40G-PLR4 QSFP-40G-PLR4 OVERVIEW PRODUCT FEATURES APPLICATIONS FUNCTIONAL DIAGRAM.

Arista QSFP-40G-PLR4. Part Number: QSFP-40G-PLR4 QSFP-40G-PLR4 OVERVIEW PRODUCT FEATURES APPLICATIONS FUNCTIONAL DIAGRAM. Part Number: QSFP-40G-PLR4 QSFP-40G-PLR4 OVERVIEW The QSFP-40G-PLR4 is a parallel 40 Gbps Quad Small Form-factor Pluggable (QSFP+) optical module. It provides increased port density and total system cost

More information

Multi-rate 10-Gigabit CWDM 40km XFP Transceivers with Digital Diagnostics

Multi-rate 10-Gigabit CWDM 40km XFP Transceivers with Digital Diagnostics Multi-rate 0-Gigabit CWDM 40km XFP Transceivers with Digital Diagnostics TXC3XGHIx000x0G Pb Product Description The TXC3XGHIx000x0G CWDM XFP multi-rate fiber optic transceivers with digital diagnostics

More information

DATASHEET 4.0. SFP, 1.25 Gbps GigE/FC, DWDM, 100GHz, SM, DDM, 32dB, 120km

DATASHEET 4.0. SFP, 1.25 Gbps GigE/FC, DWDM, 100GHz, SM, DDM, 32dB, 120km ESO-SFP-L120D-DXXX SFP, 1.25 Gbps GigE/FC, DWDM, 100GHz, SM, DDM, 32dB, 120km SO-SFP-L120D-DXXX OVERVIEW The SO-SFP-L120D-Dxxx fiber optical SFP (Small Form Pluggable) transceivers include an APD diode

More information

Cisco s CLEC Networkers Power Session

Cisco s CLEC Networkers Power Session Course Number Presentation_ID 1 Cisco s CLEC Networkers Power Session Session 2 The Business Case for ONS 15800 3 What s Driving the Demand? Data Voice 4 What s Driving the Demand? Internet 36,700,000

More information

Semiconductor Optical Amplifiers (SOAs) as Power Boosters. Applications Note No. 0001

Semiconductor Optical Amplifiers (SOAs) as Power Boosters. Applications Note No. 0001 Semiconductor Optical Amplifiers (s) as Power Boosters Applications Note No. 0001 Semiconductor Optical Amplifiers (s) as Power Boosters There is a growing need to manage the increase in loss budgets associated

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Agilent 81689A / 81689B / 81649A Compact Tunable Laser Modules February 2002 The 81689A, 81689B, 81649A compact tunable

More information

DS3880R1115. Fibrolan broad portfolio of optical transceivers include SFP+ and XFP series

DS3880R1115. Fibrolan broad portfolio of optical transceivers include SFP+ and XFP series SFP+&XFP Transceivers Fibrolan broad portfolio of optical transceivers include SFP+ and XFP series Optical Transceivers are Multi-Source Agreement (MSA) compliant These devices provide high performance

More information